mirror of https://github.com/acidanthera/audk.git
ArmPlatformPkg/PL031RealTimeClockLib: drop ArmPlatformSysConfigLib reference
The PL031 driver implements a VExpress/Juno specific hack to set the battery backed clock in addition to the PL031. However, none of the remaining VExpress based hardware we support in EDK2 actuall implements this feature so we can just remove it, and get rid of the cumbersome dependency on ArmPlatform.h. Contributed-under: TianoCore Contribution Agreement 1.1 Signed-off-by: Ard Biesheuvel <ard.biesheuvel@linaro.org> Reviewed-by: Leif Lindholm <leif.lindholm@linaro.org>
This commit is contained in:
parent
302e8eda3b
commit
0d36a219c7
|
@ -23,7 +23,6 @@
|
|||
#include <Library/RealTimeClockLib.h>
|
||||
#include <Library/MemoryAllocationLib.h>
|
||||
#include <Library/PcdLib.h>
|
||||
#include <Library/ArmPlatformSysConfigLib.h>
|
||||
#include <Library/DxeServicesTableLib.h>
|
||||
#include <Library/UefiBootServicesTableLib.h>
|
||||
#include <Library/UefiRuntimeServicesTableLib.h>
|
||||
|
@ -38,8 +37,6 @@
|
|||
|
||||
#include <Library/TimeBaseLib.h>
|
||||
|
||||
#include <ArmPlatform.h>
|
||||
|
||||
STATIC BOOLEAN mPL031Initialized = FALSE;
|
||||
STATIC EFI_EVENT mRtcVirtualAddrChangeEvent;
|
||||
STATIC UINTN mPL031RtcBase;
|
||||
|
@ -133,6 +130,11 @@ LibGetTime (
|
|||
EFI_STATUS Status = EFI_SUCCESS;
|
||||
UINT32 EpochSeconds;
|
||||
|
||||
// Ensure Time is a valid pointer
|
||||
if (Time == NULL) {
|
||||
return EFI_INVALID_PARAMETER;
|
||||
}
|
||||
|
||||
// Initialize the hardware if not already done
|
||||
if (!mPL031Initialized) {
|
||||
Status = InitializePL031 ();
|
||||
|
@ -141,27 +143,7 @@ LibGetTime (
|
|||
}
|
||||
}
|
||||
|
||||
// Snapshot the time as early in the function call as possible
|
||||
// On some platforms we may have access to a battery backed up hardware clock.
|
||||
// If such RTC exists try to use it first.
|
||||
Status = ArmPlatformSysConfigGet (SYS_CFG_RTC, &EpochSeconds);
|
||||
if (Status == EFI_UNSUPPORTED) {
|
||||
// Battery backed up hardware RTC does not exist, revert to PL031
|
||||
EpochSeconds = MmioRead32 (mPL031RtcBase + PL031_RTC_DR_DATA_REGISTER);
|
||||
Status = EFI_SUCCESS;
|
||||
} else if (EFI_ERROR (Status)) {
|
||||
// Battery backed up hardware RTC exists but could not be read due to error. Abort.
|
||||
return Status;
|
||||
} else {
|
||||
// Battery backed up hardware RTC exists and we read the time correctly from it.
|
||||
// Now sync the PL031 to the new time.
|
||||
MmioWrite32 (mPL031RtcBase + PL031_RTC_LR_LOAD_REGISTER, EpochSeconds);
|
||||
}
|
||||
|
||||
// Ensure Time is a valid pointer
|
||||
if (Time == NULL) {
|
||||
return EFI_INVALID_PARAMETER;
|
||||
}
|
||||
EpochSeconds = MmioRead32 (mPL031RtcBase + PL031_RTC_DR_DATA_REGISTER);
|
||||
|
||||
// Adjust for the correct time zone
|
||||
// The timezone setting also reflects the DST setting of the clock
|
||||
|
@ -235,19 +217,6 @@ LibSetTime (
|
|||
EpochSeconds -= SEC_PER_HOUR;
|
||||
}
|
||||
|
||||
// On some platforms we may have access to a battery backed up hardware clock.
|
||||
//
|
||||
// If such RTC exists then it must be updated first, before the PL031,
|
||||
// to minimise any time drift. This is important because the battery backed-up
|
||||
// RTC maintains the master time for the platform across reboots.
|
||||
//
|
||||
// If such RTC does not exist then the following function returns UNSUPPORTED.
|
||||
Status = ArmPlatformSysConfigSet (SYS_CFG_RTC, EpochSeconds);
|
||||
if ((EFI_ERROR (Status)) && (Status != EFI_UNSUPPORTED)){
|
||||
// Any status message except SUCCESS and UNSUPPORTED indicates a hardware failure.
|
||||
return Status;
|
||||
}
|
||||
|
||||
// Set the PL031
|
||||
MmioWrite32 (mPL031RtcBase + PL031_RTC_LR_LOAD_REGISTER, EpochSeconds);
|
||||
|
||||
|
|
|
@ -34,7 +34,6 @@
|
|||
UefiLib
|
||||
DebugLib
|
||||
PcdLib
|
||||
ArmPlatformSysConfigLib
|
||||
DxeServicesTableLib
|
||||
TimeBaseLib
|
||||
UefiRuntimeLib
|
||||
|
|
Loading…