ShellPkg-ShellApp: Provide fully-qualified path to shell scripts

Provide fully-qualified path to shell scripts

Section 3.6.2 of version 2.2 of the shell specification requires that
the first positional argument (i.e. arg 0) of a shell script resolves
to "the full path name of the script itself."

Ensure that the startup script and any scripts launched by the shell
meet this requirement.

Contributed-under: TianoCore Contribution Agreement 1.1
Signed-off-by: Jim Dailey <jim_dailey@dell.com>
Reviewed-by: Ruiyu Ni <ruiyu.ni@intel.com>
This commit is contained in:
Jim.Dailey@dell.com 2018-10-30 05:14:51 +08:00 committed by Ruiyu Ni
parent 9ba404d664
commit 764c21f4aa
1 changed files with 23 additions and 3 deletions

View File

@ -3,6 +3,7 @@
Copyright (c) 2009 - 2018, Intel Corporation. All rights reserved.<BR>
(C) Copyright 2013-2014 Hewlett-Packard Development Company, L.P.<BR>
Copyright 2015-2018 Dell Technologies.<BR>
This program and the accompanying materials
are licensed and made available under the terms and conditions of the BSD License
which accompanies this distribution. The full text of the license may be found at
@ -1208,6 +1209,7 @@ DoStartupScript(
UINTN Delay;
EFI_INPUT_KEY Key;
CHAR16 *FileStringPath;
CHAR16 *FullFileStringPath;
UINTN NewSize;
Key.UnicodeChar = CHAR_NULL;
@ -1275,7 +1277,13 @@ DoStartupScript(
FileStringPath = LocateStartupScript (ImagePath, FilePath);
if (FileStringPath != NULL) {
Status = RunScriptFile (FileStringPath, NULL, L"", ShellInfoObject.NewShellParametersProtocol);
FullFileStringPath = FullyQualifyPath(FileStringPath);
if (FullFileStringPath == NULL) {
Status = RunScriptFile (FileStringPath, NULL, FileStringPath, ShellInfoObject.NewShellParametersProtocol);
} else {
Status = RunScriptFile (FullFileStringPath, NULL, FullFileStringPath, ShellInfoObject.NewShellParametersProtocol);
FreePool(FullFileStringPath);
}
FreePool (FileStringPath);
} else {
//
@ -2429,6 +2437,7 @@ RunCommandOrFile(
EFI_STATUS Status;
EFI_STATUS StartStatus;
CHAR16 *CommandWithPath;
CHAR16 *FullCommandWithPath;
EFI_DEVICE_PATH_PROTOCOL *DevPath;
SHELL_STATUS CalleeExitStatus;
@ -2474,7 +2483,13 @@ RunCommandOrFile(
}
switch (Type) {
case Script_File_Name:
Status = RunScriptFile (CommandWithPath, NULL, CmdLine, ParamProtocol);
FullCommandWithPath = FullyQualifyPath(CommandWithPath);
if (FullCommandWithPath == NULL) {
Status = RunScriptFile (CommandWithPath, NULL, CmdLine, ParamProtocol);
} else {
Status = RunScriptFile (FullCommandWithPath, NULL, CmdLine, ParamProtocol);
FreePool(FullCommandWithPath);
}
break;
case Efi_Application:
//
@ -2812,7 +2827,12 @@ RunScriptFileHandle (
DeleteScriptFileStruct(NewScriptFile);
return (EFI_OUT_OF_RESOURCES);
}
for (LoopVar = 0 ; LoopVar < 10 && LoopVar < NewScriptFile->Argc; LoopVar++) {
//
// Put the full path of the script file into Argv[0] as required by section
// 3.6.2 of version 2.2 of the shell specification.
//
NewScriptFile->Argv[0] = StrnCatGrow(&NewScriptFile->Argv[0], NULL, NewScriptFile->ScriptName, 0);
for (LoopVar = 1 ; LoopVar < 10 && LoopVar < NewScriptFile->Argc; LoopVar++) {
ASSERT(NewScriptFile->Argv[LoopVar] == NULL);
NewScriptFile->Argv[LoopVar] = StrnCatGrow(&NewScriptFile->Argv[LoopVar], NULL, ShellInfoObject.NewShellParametersProtocol->Argv[LoopVar], 0);
if (NewScriptFile->Argv[LoopVar] == NULL) {