ArmVirtPkg: Move PcdMonitorConduitHvc

This moves the PcdMonitorConduitHvc from PcdsFeatureFlag.Common to
PcdsFixedAtBuild.Common

This is a follow on to the previous commit:
ArmPkg: Allow SMC/HVC monitor conduit to be specified at runtime

ArmVirtQemu may execute at EL2, in which case monitor calls are
generally made using SMC instructions instead of HVC instructions.

Whether or not this is the case can only be decided at runtime, and so
the associated PCD needs to be settable at runtime, if the platform
definition chooses so. This implies a boolean PCD, given that a feature
PCD is build-time configurable only.

Cc: Leif Lindholm <quic_llindhol@quicinc.com>
Cc: Ard Biesheuvel <ardb+tianocore@kernel.org>
Cc: Sami Mujawar <sami.mujawar@arm.com>

Signed-off-by: Doug Flick [MSFT] <doug.edk2@gmail.com>
Reviewed-by: Ard Biesheuvel <ardb@kernel.org>
This commit is contained in:
Flickdm 2024-05-20 11:06:42 -07:00 committed by mergify[bot]
parent 32460bb5b1
commit 9440986d4e
1 changed files with 2 additions and 2 deletions

View File

@ -126,8 +126,6 @@
# Use MMIO for accessing RTC controller registers.
gPcAtChipsetPkgTokenSpaceGuid.PcdRtcUseMmio|TRUE
gArmTokenSpaceGuid.PcdMonitorConduitHvc|TRUE
[PcdsFixedAtBuild.common]
gEfiMdePkgTokenSpaceGuid.PcdDebugPrintErrorLevel|0x8000000F
@ -167,6 +165,8 @@
#
gEmbeddedTokenSpaceGuid.PcdPrePiCpuIoSize|16
gArmTokenSpaceGuid.PcdMonitorConduitHvc|TRUE
[PcdsPatchableInModule.common]
#
# This will be overridden in the code