BaseTools: refactor the error for PCD value is negative or exceed max

refactor the error handling for the PCD value that is negative or it
exceed the max value.

Cc: Liming Gao <liming.gao@intel.com>
Cc: Yonghong Zhu <yonghong.zhu@intel.com>
Contributed-under: TianoCore Contribution Agreement 1.1
Signed-off-by: Zhiju.Fan <zhijux.fan@intel.com>
Reviewed-by: Yonghong Zhu <yonghong.zhu@intel.com>
This commit is contained in:
zhijufan 2018-09-27 14:08:15 +08:00 committed by Yonghong Zhu
parent 5b02be4d9a
commit c526dcd40f
3 changed files with 30 additions and 75 deletions

View File

@ -1015,50 +1015,19 @@ def CreateModulePcdCode(Info, AutoGenC, AutoGenH, Pcd):
EdkLogger.error("build", AUTOGEN_ERROR,
"PCD value is not valid dec or hex number for datum type [%s] of PCD %s.%s" % (Pcd.DatumType, Pcd.TokenSpaceGuidCName, TokenCName),
ExtraData="[%s]" % str(Info))
if Pcd.DatumType == TAB_UINT64:
if ValueNumber < 0:
EdkLogger.error("build", AUTOGEN_ERROR,
"PCD can't be set to negative value for datum type [%s] of PCD %s.%s" % (Pcd.DatumType, Pcd.TokenSpaceGuidCName, TokenCName),
ExtraData="[%s]" % str(Info))
elif ValueNumber >= 0x10000000000000000:
EdkLogger.error("build", AUTOGEN_ERROR,
"Too large PCD value for datum type [%s] of PCD %s.%s" % (Pcd.DatumType, Pcd.TokenSpaceGuidCName, TokenCName),
ExtraData="[%s]" % str(Info))
if not Value.endswith('ULL'):
Value += 'ULL'
elif Pcd.DatumType == TAB_UINT32:
if ValueNumber < 0:
EdkLogger.error("build", AUTOGEN_ERROR,
"PCD can't be set to negative value for datum type [%s] of PCD %s.%s" % (Pcd.DatumType, Pcd.TokenSpaceGuidCName, TokenCName),
ExtraData="[%s]" % str(Info))
elif ValueNumber >= 0x100000000:
EdkLogger.error("build", AUTOGEN_ERROR,
"Too large PCD value for datum type [%s] of PCD %s.%s" % (Pcd.DatumType, Pcd.TokenSpaceGuidCName, TokenCName),
ExtraData="[%s]" % str(Info))
if not Value.endswith('U'):
Value += 'U'
elif Pcd.DatumType == TAB_UINT16:
if ValueNumber < 0:
EdkLogger.error("build", AUTOGEN_ERROR,
"PCD can't be set to negative value for datum type [%s] of PCD %s.%s" % (Pcd.DatumType, Pcd.TokenSpaceGuidCName, TokenCName),
ExtraData="[%s]" % str(Info))
elif ValueNumber >= 0x10000:
EdkLogger.error("build", AUTOGEN_ERROR,
"Too large PCD value for datum type [%s] of PCD %s.%s" % (Pcd.DatumType, Pcd.TokenSpaceGuidCName, TokenCName),
ExtraData="[%s]" % str(Info))
if not Value.endswith('U'):
Value += 'U'
elif Pcd.DatumType == TAB_UINT8:
if ValueNumber < 0:
EdkLogger.error("build", AUTOGEN_ERROR,
"PCD can't be set to negative value for datum type [%s] of PCD %s.%s" % (Pcd.DatumType, Pcd.TokenSpaceGuidCName, TokenCName),
ExtraData="[%s]" % str(Info))
elif ValueNumber >= 0x100:
EdkLogger.error("build", AUTOGEN_ERROR,
"Too large PCD value for datum type [%s] of PCD %s.%s" % (Pcd.DatumType, Pcd.TokenSpaceGuidCName, TokenCName),
ExtraData="[%s]" % str(Info))
if not Value.endswith('U'):
Value += 'U'
if ValueNumber < 0:
EdkLogger.error("build", AUTOGEN_ERROR,
"PCD can't be set to negative value for datum type [%s] of PCD %s.%s" % (Pcd.DatumType, Pcd.TokenSpaceGuidCName, TokenCName),
ExtraData="[%s]" % str(Info))
elif ValueNumber > MAX_VAL_TYPE[Pcd.DatumType]:
EdkLogger.error("build", AUTOGEN_ERROR,
"Too large PCD value for datum type [%s] of PCD %s.%s" % (Pcd.DatumType, Pcd.TokenSpaceGuidCName, TokenCName),
ExtraData="[%s]" % str(Info))
if Pcd.DatumType == TAB_UINT64 and not Value.endswith('ULL'):
Value += 'ULL'
elif Pcd.DatumType != TAB_UINT64 and not Value.endswith('U'):
Value += 'U'
if Pcd.DatumType not in TAB_PCD_NUMERIC_TYPES:
if not Pcd.MaxDatumSize:
EdkLogger.error("build", AUTOGEN_ERROR,

View File

@ -21,6 +21,7 @@ import array
import re
from Common.LongFilePathSupport import OpenLongFilePath as open
from struct import *
from Common.DataType import MAX_SIZE_TYPE, MAX_VAL_TYPE
import Common.EdkLogger as EdkLogger
import Common.BuildToolError as BuildToolError
@ -125,37 +126,18 @@ class PcdEntry:
EdkLogger.error("BPDG", BuildToolError.FORMAT_INVALID,
"Invalid size %d for PCD %s in integer datum size(File: %s Line: %s)." % (Size, self.PcdCName, self.FileName, self.Lineno))
if Size == 1:
if IntValue < 0:
EdkLogger.error("BPDG", BuildToolError.FORMAT_INVALID,
"PCD can't be set to negative value %d for PCD %s in UINT8 datum type(File: %s Line: %s)." % (IntValue, self.PcdCName, self.FileName, self.Lineno))
elif IntValue >= 0x100:
EdkLogger.error("BPDG", BuildToolError.FORMAT_INVALID,
"Too large PCD value %d for datum type UINT8 for PCD %s(File: %s Line: %s)." % (IntValue, self.PcdCName, self.FileName, self.Lineno))
elif Size == 2:
if IntValue < 0:
EdkLogger.error("BPDG", BuildToolError.FORMAT_INVALID,
"PCD can't be set to negative value %d for PCD %s in UINT16 datum type(File: %s Line: %s)." % (IntValue, self.PcdCName, self.FileName, self.Lineno))
elif IntValue >= 0x10000:
EdkLogger.error("BPDG", BuildToolError.FORMAT_INVALID,
"Too large PCD value %d for datum type UINT16 for PCD %s(File: %s Line: %s)." % (IntValue, self.PcdCName, self.FileName, self.Lineno))
elif Size == 4:
if IntValue < 0:
EdkLogger.error("BPDG", BuildToolError.FORMAT_INVALID,
"PCD can't be set to negative value %d for PCD %s in UINT32 datum type(File: %s Line: %s)." % (IntValue, self.PcdCName, self.FileName, self.Lineno))
elif IntValue >= 0x100000000:
EdkLogger.error("BPDG", BuildToolError.FORMAT_INVALID,
"Too large PCD value %d for datum type UINT32 for PCD %s(File: %s Line: %s)." % (IntValue, self.PcdCName, self.FileName, self.Lineno))
elif Size == 8:
if IntValue < 0:
EdkLogger.error("BPDG", BuildToolError.FORMAT_INVALID,
"PCD can't be set to negative value %d for PCD %s in UINT32 datum type(File: %s Line: %s)." % (IntValue, self.PcdCName, self.FileName, self.Lineno))
elif IntValue >= 0x10000000000000000:
EdkLogger.error("BPDG", BuildToolError.FORMAT_INVALID,
"Too large PCD value %d for datum type UINT32 for PCD %s(File: %s Line: %s)." % (IntValue, self.PcdCName, self.FileName, self.Lineno))
else:
EdkLogger.error("BPDG", BuildToolError.FORMAT_INVALID,
"Invalid size %d for PCD %s in integer datum size(File: %s Line: %s)." % (Size, self.PcdCName, self.FileName, self.Lineno))
for Type, MaxSize in MAX_SIZE_TYPE.items():
if Type == 'BOOLEAN':
continue
if Size == MaxSize:
if IntValue < 0:
EdkLogger.error("BPDG", BuildToolError.FORMAT_INVALID,
"PCD can't be set to negative value %d for PCD %s in %s datum type(File: %s Line: %s)." % (
IntValue, self.PcdCName, Type, self.FileName, self.Lineno))
elif IntValue > MAX_VAL_TYPE[Type]:
EdkLogger.error("BPDG", BuildToolError.FORMAT_INVALID,
"Too large PCD value %d for datum type %s for PCD %s(File: %s Line: %s)." % (
IntValue, Type, self.PcdCName, self.FileName, self.Lineno))
try:
self.PcdValue = pack(_FORMAT_CHAR[Size], IntValue)

View File

@ -1589,8 +1589,12 @@ def CheckPcdDatum(Type, Value):
return False, "Invalid value [%s] of type [%s]; must be one of TRUE, True, true, 0x1, 0x01, 1"\
", FALSE, False, false, 0x0, 0x00, 0" % (Value, Type)
elif Type in [TAB_UINT8, TAB_UINT16, TAB_UINT32, TAB_UINT64]:
if Value and int(Value, 0) < 0:
return False, "PCD can't be set to negative value[%s] for datum type [%s]" % (Value, Type)
try:
Value = long(Value, 0)
if Value > MAX_VAL_TYPE[Type]:
return False, "Too large PCD value[%s] for datum type [%s]" % (Value, Type)
except:
return False, "Invalid value [%s] of type [%s];"\
" must be a hexadecimal, decimal or octal in C language format." % (Value, Type)