The original driver cannot handle the case when system time runs from 1999/12/31 23:59:59
to 2000/1/1 0:0:0.
A simple test to set system time to 1999/12/31 23:59:59 can expose this bug.
The patch limits the driver to only support year in 100 range and decide the century value based
on the supporting range: Century either equals to PcdMinimalYear / 100 or equals to PcdMinimalYear / 100 + 1.
The patch passed the Y2K test.
However with year range [1998, 2097], when system time is 2097/12/31 23:59:59,
the next second system time will become 1998/1/1 0:0:0. I think it's a acceptable limitation.
Contributed-under: TianoCore Contribution Agreement 1.0
Signed-off-by: Ruiyu Ni <ruiyu.ni@intel.com>
Reviewed-by: Feng Tian <feng.tian@intel.com>
git-svn-id: https://svn.code.sf.net/p/edk2/code/trunk/edk2@17624 6f19259b-4bc3-4df7-8a09-765794883524
1. Module UNI and Package UNI files are not DOS format. Convert them to DOS format.
2. BaseAcpiTimerLib and DxeAcpiTimerLib has the same module name. Update them to the different name, and add the module uni file with the updated module name.
Contributed-under: TianoCore Contribution Agreement 1.0
Signed-off-by: Gao, Liming <liming.gao@intel.com>
git-svn-id: https://svn.code.sf.net/p/edk2/code/trunk/edk2@16046 6f19259b-4bc3-4df7-8a09-765794883524
2. Add MODULE_UNI_FILE file that contains the localized Abstract and Description of a module.
a. Addresses an information gap between INF files and the UEFI Distribution Packaging Specification XML schema
b. There will be an associated update to UPT in BaseTools to consume MODULE_UNI_FILE and associated UNI file during UDP creation that performs the INF -> XML conversion.
c. There will be an associated update to UPT in BaseTools to produce MODULE_UNI_FILE and associated UNI file during UDP installation that performs the XML -> INF conversion.
3. Add Module Extra UNI file that provides the localized Name of a module.
a. [UserExtensions.TianoCore."ExtraFiles"] provides an easy method for a module to specify extra files not listed in [Sources] or [Binaries] sections to be added to a UDP without having to list the files in the UPT package information data file.
b. There will be an associated update to UPT in BaseTools to package up files listed in [UserExtensions.TianoCore."ExtraFiles"] during UDP creation.
c. UNI file contains localized name of a module to go along with the localized Abstract and Description from the MODULE_UNI_FILE.
Contributed-under: TianoCore Contribution Agreement 1.0
Signed-off-by: Qiu, Shumin <shumin.qiu@intel.com>
Reviewed-by: Gao, Liming <liming.gao@intel.com>
git-svn-id: https://svn.code.sf.net/p/edk2/code/trunk/edk2@15943 6f19259b-4bc3-4df7-8a09-765794883524
1. Usage information in INF file comment blocks are either incomplete or incorrect.
This includes usage information for Protocols/PPIs/GUIDs/PCDs/HOBs/Events/BootModes.
The syntax for usage information in comment blocks is defined in the EDK II Module Information (INF) Specification
Contributed-under: TianoCore Contribution Agreement 1.0
Signed-off-by: Qiu, Shumin <shumin.qiu@intel.com>
Reviewed-by: Gao, Liming <liming.gao@intel.com>
git-svn-id: https://svn.code.sf.net/p/edk2/code/trunk/edk2@15942 6f19259b-4bc3-4df7-8a09-765794883524
1. RtcTimeFieldsValid() has bug checking the validity of TIME fields, which causes SetTime() will not return EFI_INVALID_PARAMETER when it is fed with invliad time fields.
2. Logical error in handling Time Zone and Day Light Saving.GetTime() won't return Time Zone and Day Light Saving set by last SetTime() call.
git-svn-id: https://edk2.svn.sourceforge.net/svnroot/edk2/trunk/edk2@8948 6f19259b-4bc3-4df7-8a09-765794883524