This patch fixes the following Ecc reported error:
There should be no initialization of a variable as
part of its declaration
Signed-off-by: Pierre Gondois <Pierre.Gondois@arm.com>
Reviewed-by: Ard Biesheuvel <ard.biesheuvel@arm.com>
A paragraph sign in a comment came from some ISO8859 encoding,
convert it to the word "section" to remain 7-bit safe, since we're
not actually doing anything special.
Cc: Ard Biesheuvel <ard.biesheuvel@linaro.org>
Cc: "Kinney, Michael D" <michael.d.kinney@intel.com>
Signed-off-by: Leif Lindholm <leif.lindholm@linaro.org>
Acked-by: Ard Biesheuvel <ard.biesheuvel@linaro.org>
Reviewed-by: Philippe Mathieu-Daude <philmd@redhat.com>
Add function to allow enabling and disabling of the clock using the SCMI
interface. Add gArmScmiClock2ProtocolGuid to distinguish platforms that
support new API from those that just have the older protocol.
SCMI_CLOCK2_PROTOCOL also adds a version parameter to allow for future
changes. It is placed after the functions that are present in the
existing protocol to allow SCMI_CLOCK2_PROTOCOL to be cast to
SCMI_CLOCK_PROTOCOL so that only a single implementation of those
function are needed.
Contributed-under: TianoCore Contribution Agreement 1.1
Signed-off-by: Jeff Brasen <jbrasen@nvidia.com>
Reviewed-by: Ard Biesheuvel <ard.biesheuvel@linaro.org>
Dynamically allocate the buffer to receive the SCMI protocol list.
This makes MAX_PROTOCOLS redundant, so it is removed.
It also fixes one minor code alignment issue and removes an unused
macro PROTOCOL_MASK.
Contributed-under: TianoCore Contribution Agreement 1.1
Signed-off-by: Girish Pathak <girish.pathak@arm.com>
Tested-by: Sudeep Holla <sudeep.holla@arm.com>
Reviewed-by: Ard Biesheuvel <ard.biesheuvel@linaro.org>
This change fixes a bug in the SCMI DXE which is observed with the
upcoming release of the SCP firmware.
The PROTOCOL_ID_MASK (0xF) which is used to generate an index in
the ProtocolInitFxns is wrong because protocol ids can be
anywhere in 0x10 - 15 or 0x80 - FF range. This mask generates
the same index for two different protocols e.g. for protocol ids
0x10 and 0x90, which causes duplicate initialization of a protocol
resulting in a failure.
This change removes the use of PROTOCOL_ID_MASK and instead
uses a list of protocol ids and their initialization functions
to identify a supported protocol and initialize it.
Contributed-under: TianoCore Contribution Agreement 1.1
Signed-off-by: Girish Pathak <girish.pathak@arm.com>
Tested-by: Sudeep Holla <sudeep.holla@arm.com>
Reviewed-by: Ard Biesheuvel <ard.biesheuvel@linaro.org>
This change introduces a new SCMI protocol driver for
Arm systems. The driver currently supports only clock
and performance management protocols. Other protocols
will be added as and when needed.
Clock management protocol is used to configure various clocks
available on the platform e.g. HDLCD clock on the Juno platforms.
Whereas performance management protocol allows adjustment
of various performance domains. Currently this is used to evaluate
performance of the Juno platform.
Contributed-under: TianoCore Contribution Agreement 1.1
Signed-off-by: Girish Pathak <girish.pathak@arm.com>
Signed-off-by: Evan Lloyd <evan.lloyd@arm.com>
Reviewed-by: Leif Lindholm <leif.lindholm@linaro.org>