Misuse of retransmisson of DHCPDISCOVER in Dhcp4 drive, the root cause is that DHCP doesn't retransmit discover message when timeout.
[Solution]:
Correct the mechanism for discover message.
[Impaction]:
Dhcp4Dxe.
[Reference Info]:
EDK tracker 1150 - Misuse of retransmisson of DHCPDISCOVER in Dhcp4 drive.
git-svn-id: https://edk2.svn.sourceforge.net/svnroot/edk2/trunk/edk2@5366 6f19259b-4bc3-4df7-8a09-765794883524
EDK1145 Cursor mising in shell in some case
EDK1099: Dell - [HII] HiiGetFontInfo() not retrieve the system font by FoFontInfoMask
EDK1127: [UEFI 2.10] Keyboard layout support
EDK1129: [UEFI HII] GUID is represented wrongly in Config String
And some other fixes such as
*[UEFI HII] HiiGetAltCfg is generating "Name=" sub string in the wrong format
*UEFI HII: GetUnicodeStringTextOrSize() doesn't handle NULL StringDest properly
*GetFontInfo() need be updated to avoid iteration
*HIIStringProtocolTest failed on multiple platform
*[Uefi 2.1] Comply with latest Hii ECR
* GetFontInfo() need be updated to avoid iteration
git-svn-id: https://edk2.svn.sourceforge.net/svnroot/edk2/trunk/edk2@5361 6f19259b-4bc3-4df7-8a09-765794883524
Problem with PXE boot to Windows Server 2008 install. The reason is that UdpRead and UdpWrite interfaces cannot work well with the same UDP instance.
[Solution]
Use separate instances for UDP Read and UDP write in UefiPxeBC module.
[Impaction]:
UefiPxeBcDxe and Udp4Dxe module.
[Reference Info]:
EDK tracker 1133 - Problem with PXE boot to Windows Server 2008 install.
git-svn-id: https://edk2.svn.sourceforge.net/svnroot/edk2/trunk/edk2@5303 6f19259b-4bc3-4df7-8a09-765794883524
Fixed one bug in PciBus. PciBus doesn't clear the bridges bus number for all the root bridges before scanning any of them.
[Description]:
The static IP configuration no long works in the EDK 1.04 network package. The cause is that changing the type of EFI_IP4_IPCONFIG_DATA.RouteTable from a variable length array to a pointer is not clean. If the whole structure is read from variable, the pointer is invalid.
[Solution]
Fix the pointer before using it
[Impaction]:
Ip4ConfigDxe module.
[Reference Info]:
EDK tracker 1134 - Static IP configuration no long works.
git-svn-id: https://edk2.svn.sourceforge.net/svnroot/edk2/trunk/edk2@5291 6f19259b-4bc3-4df7-8a09-765794883524
Memory may leak because the handles in IScsiUpdateDeviceList is not freed if the "iSCSIDeviceList" already exists
[Impaction]
add Free() func to free memory properly.
[Reference Info]
The Handles in IScsiUpdateDeviceList is not freed if the "iSCSIDeviceList" already exists
git-svn-id: https://edk2.svn.sourceforge.net/svnroot/edk2/trunk/edk2@5211 6f19259b-4bc3-4df7-8a09-765794883524
add a judgement of whether the control command is equal with previous one or not.
[Impaction]
Judge if the control command is equaled with previous one. This handler can improve performance.
[Reference Info]
Currently the terminal driver outputs control commands upon user's request regardless of whether the new attribute is the same as previous one or not.
Actually, it could be implemented as only outputting control command when the new Attribute is different than previous one
git-svn-id: https://edk2.svn.sourceforge.net/svnroot/edk2/trunk/edk2@5113 6f19259b-4bc3-4df7-8a09-765794883524
change the old code style to comply with Doxgen format
[Impaction]
add comments for every function
[Reference Info]
add comments to achieve the highest standard of code quality matrix
git-svn-id: https://edk2.svn.sourceforge.net/svnroot/edk2/trunk/edk2@5079 6f19259b-4bc3-4df7-8a09-765794883524
solve the big file transfer issue using ISCSI
[Impaction]
change the control flow on IScsiExecuteScsiCommand function
[Reference Info]
The original design incorrectly uses a timer (its span is usually 2 seconds) to ensure the timely execution of CMD PDU send by initiator. For example: When initiator delivers a CMD PDU(WRITE command) in which the ExpDataXferLength filed is larger than DataSegmentLength field, according to ISCSI protocol spec, the target will respond it with a R2T PDU which is followed by a sequential DATA-OUT PDUs. In this situation, the original code may loop to deal with the arrival packet until initiator receives a RESPONSE PDU or the timer is expired. This way may cause the bigger file is more likely to fail.
git-svn-id: https://edk2.svn.sourceforge.net/svnroot/edk2/trunk/edk2@5044 6f19259b-4bc3-4df7-8a09-765794883524