The macros EL1_OR_EL2() and EL1_OR_EL2_OR_EL3() allow conditional execution
of assembly sequences based on the current exception level, by jumping to
caller supplied labels 1f, 2f or 3f. However, the jump to 1f is actually
a fallthrough, which means the EL1 code needs to follow right after the
macro invocation, and the 1f label is ignored.
So let's fix this by making all jumps explicit.
Contributed-under: TianoCore Contribution Agreement 1.0
Signed-off-by: Ard Biesheuvel <ard.biesheuvel@linaro.org>
Reviewed-by: Leif Lindholm <leif.lindholm@linaro.org>
Reviewed-by: Eugene Cohen <eugene@hp.com>
The SetPrimaryStack and InitializePrimaryStack macros are no longer
used now that we removed support for ArmPlatformGlobalVariableLib.
So remove the various versions of them.
Contributed-under: TianoCore Contribution Agreement 1.0
Signed-off-by: Ard Biesheuvel <ard.biesheuvel@linaro.org>
Reviewed-by: Leif Lindholm <leif.lindholm@linaro.org>
git-svn-id: https://svn.code.sf.net/p/edk2/code/trunk/edk2@19004 6f19259b-4bc3-4df7-8a09-765794883524
Several assembler macros use a loop at the label "dead" to trap an error.
This is difficult to debug as there is no indication of how one arrived at the loop.
This change replaces dead with distinct loops locally in the macro,
which means the cause of the hang is detectable to the debugger.
Contributed-under: TianoCore Contribution Agreement 1.0
Signed-off-by: Olivier Martin <olivier.martin@arm.com>
git-svn-id: https://svn.code.sf.net/p/edk2/code/trunk/edk2@15273 6f19259b-4bc3-4df7-8a09-765794883524