The string being built had a character being overwritten. This
also lead to a NULL character being sent out to the serial port
for the last character in the string.
git-svn-id: https://edk2.svn.sourceforge.net/svnroot/edk2/trunk/edk2@9669 6f19259b-4bc3-4df7-8a09-765794883524
1) Update all implementations of ReportStatusCodeExtractDebugInfo() to use an argument of type BASE_LIST instead of VA_LIST.
2) Update the implementation of DebugPrint() in PeiDxeDebugLibReportStatusCode to convert a VA_LIST to a BASE_LIST before passing the data to report status code.
3) Update status code listeners to use the BASE_LIST based APIs in the PrintLib instead of the VA_LIST based APIs, since ReportStatusCodeExtractDebugInfo() was updated to return a parameter of type BASE_LIST.
git-svn-id: https://edk2.svn.sourceforge.net/svnroot/edk2/trunk/edk2@8406 6f19259b-4bc3-4df7-8a09-765794883524