audk/MdePkg/Include/IndustryStandard/SdramSpdDdr3.h

770 lines
34 KiB
C

/** @file
This file contains definitions for SPD DDR3.
Copyright (c) 2016, Intel Corporation. All rights reserved.<BR>
This program and the accompanying materials
are licensed and made available under the terms and conditions of the BSD License
which accompanies this distribution. The full text of the license may be found at
http://opensource.org/licenses/bsd-license.php
THE PROGRAM IS DISTRIBUTED UNDER THE BSD LICENSE ON AN "AS IS" BASIS,
WITHOUT WARRANTIES OR REPRESENTATIONS OF ANY KIND, EITHER EXPRESS OR IMPLIED.
@par Revision Reference:
- Serial Presence Detect (SPD) for DDR3 SDRAM Modules Document Release 6
http://www.jedec.org/sites/default/files/docs/4_01_02_11R21A.pdf
**/
#ifndef _SDRAM_SPD_DDR3_H_
#define _SDRAM_SPD_DDR3_H_
#pragma pack (push, 1)
typedef union {
struct {
UINT8 BytesUsed : 4; ///< Bits 3:0
UINT8 BytesTotal : 3; ///< Bits 6:4
UINT8 CrcCoverage : 1; ///< Bits 7:7
} Bits;
UINT8 Data;
} SPD3_DEVICE_DESCRIPTION_STRUCT;
typedef union {
struct {
UINT8 Minor : 4; ///< Bits 3:0
UINT8 Major : 4; ///< Bits 7:4
} Bits;
UINT8 Data;
} SPD3_REVISION_STRUCT;
typedef union {
struct {
UINT8 Type : 8; ///< Bits 7:0
} Bits;
UINT8 Data;
} SPD3_DRAM_DEVICE_TYPE_STRUCT;
typedef union {
struct {
UINT8 ModuleType : 4; ///< Bits 3:0
UINT8 Reserved : 4; ///< Bits 7:4
} Bits;
UINT8 Data;
} SPD3_MODULE_TYPE_STRUCT;
typedef union {
struct {
UINT8 Density : 4; ///< Bits 3:0
UINT8 BankAddress : 3; ///< Bits 6:4
UINT8 Reserved : 1; ///< Bits 7:7
} Bits;
UINT8 Data;
} SPD3_SDRAM_DENSITY_BANKS_STRUCT;
typedef union {
struct {
UINT8 ColumnAddress : 3; ///< Bits 2:0
UINT8 RowAddress : 3; ///< Bits 5:3
UINT8 Reserved : 2; ///< Bits 7:6
} Bits;
UINT8 Data;
} SPD3_SDRAM_ADDRESSING_STRUCT;
typedef union {
struct {
UINT8 OperationAt1_50 : 1; ///< Bits 0:0
UINT8 OperationAt1_35 : 1; ///< Bits 1:1
UINT8 OperationAt1_25 : 1; ///< Bits 2:2
UINT8 Reserved : 5; ///< Bits 7:3
} Bits;
UINT8 Data;
} SPD3_MODULE_NOMINAL_VOLTAGE_STRUCT;
typedef union {
struct {
UINT8 SdramDeviceWidth : 3; ///< Bits 2:0
UINT8 RankCount : 3; ///< Bits 5:3
UINT8 Reserved : 2; ///< Bits 7:6
} Bits;
UINT8 Data;
} SPD3_MODULE_ORGANIZATION_STRUCT;
typedef union {
struct {
UINT8 PrimaryBusWidth : 3; ///< Bits 2:0
UINT8 BusWidthExtension : 2; ///< Bits 4:3
UINT8 Reserved : 3; ///< Bits 7:5
} Bits;
UINT8 Data;
} SPD3_MODULE_MEMORY_BUS_WIDTH_STRUCT;
typedef union {
struct {
UINT8 Divisor : 4; ///< Bits 3:0
UINT8 Dividend : 4; ///< Bits 7:4
} Bits;
UINT8 Data;
} SPD3_FINE_TIMEBASE_STRUCT;
typedef union {
struct {
UINT8 Dividend : 8; ///< Bits 7:0
} Bits;
UINT8 Data;
} SPD3_MEDIUM_TIMEBASE_DIVIDEND_STRUCT;
typedef union {
struct {
UINT8 Divisor : 8; ///< Bits 7:0
} Bits;
UINT8 Data;
} SPD3_MEDIUM_TIMEBASE_DIVISOR_STRUCT;
typedef struct {
SPD3_MEDIUM_TIMEBASE_DIVIDEND_STRUCT Dividend; ///< Medium Timebase (MTB) Dividend
SPD3_MEDIUM_TIMEBASE_DIVISOR_STRUCT Divisor; ///< Medium Timebase (MTB) Divisor
} SPD3_MEDIUM_TIMEBASE;
typedef union {
struct {
UINT8 tCKmin : 8; ///< Bits 7:0
} Bits;
UINT8 Data;
} SPD3_TCK_MIN_MTB_STRUCT;
typedef union {
struct {
UINT16 Cl4 : 1; ///< Bits 0:0
UINT16 Cl5 : 1; ///< Bits 1:1
UINT16 Cl6 : 1; ///< Bits 2:2
UINT16 Cl7 : 1; ///< Bits 3:3
UINT16 Cl8 : 1; ///< Bits 4:4
UINT16 Cl9 : 1; ///< Bits 5:5
UINT16 Cl10 : 1; ///< Bits 6:6
UINT16 Cl11 : 1; ///< Bits 7:7
UINT16 Cl12 : 1; ///< Bits 8:8
UINT16 Cl13 : 1; ///< Bits 9:9
UINT16 Cl14 : 1; ///< Bits 10:10
UINT16 Cl15 : 1; ///< Bits 11:11
UINT16 Cl16 : 1; ///< Bits 12:12
UINT16 Cl17 : 1; ///< Bits 13:13
UINT16 Cl18 : 1; ///< Bits 14:14
UINT16 Reserved : 1; ///< Bits 15:15
} Bits;
UINT16 Data;
UINT8 Data8[2];
} SPD3_CAS_LATENCIES_SUPPORTED_STRUCT;
typedef union {
struct {
UINT8 tAAmin : 8; ///< Bits 7:0
} Bits;
UINT8 Data;
} SPD3_TAA_MIN_MTB_STRUCT;
typedef union {
struct {
UINT8 tWRmin : 8; ///< Bits 7:0
} Bits;
UINT8 Data;
} SPD3_TWR_MIN_MTB_STRUCT;
typedef union {
struct {
UINT8 tRCDmin : 8; ///< Bits 7:0
} Bits;
UINT8 Data;
} SPD3_TRCD_MIN_MTB_STRUCT;
typedef union {
struct {
UINT8 tRRDmin : 8; ///< Bits 7:0
} Bits;
UINT8 Data;
} SPD3_TRRD_MIN_MTB_STRUCT;
typedef union {
struct {
UINT8 tRPmin : 8; ///< Bits 7:0
} Bits;
UINT8 Data;
} SPD3_TRP_MIN_MTB_STRUCT;
typedef union {
struct {
UINT8 tRASminUpper : 4; ///< Bits 3:0
UINT8 tRCminUpper : 4; ///< Bits 7:4
} Bits;
UINT8 Data;
} SPD3_TRAS_TRC_MIN_MTB_STRUCT;
typedef union {
struct {
UINT8 tRASmin : 8; ///< Bits 7:0
} Bits;
UINT8 Data;
} SPD3_TRAS_MIN_MTB_STRUCT;
typedef union {
struct {
UINT8 tRCmin : 8; ///< Bits 7:0
} Bits;
UINT8 Data;
} SPD3_TRC_MIN_MTB_STRUCT;
typedef union {
struct {
UINT16 tRFCmin : 16; ///< Bits 15:0
} Bits;
UINT16 Data;
UINT8 Data8[2];
} SPD3_TRFC_MIN_MTB_STRUCT;
typedef union {
struct {
UINT8 tWTRmin : 8; ///< Bits 7:0
} Bits;
UINT8 Data;
} SPD3_TWTR_MIN_MTB_STRUCT;
typedef union {
struct {
UINT8 tRTPmin : 8; ///< Bits 7:0
} Bits;
UINT8 Data;
} SPD3_TRTP_MIN_MTB_STRUCT;
typedef union {
struct {
UINT8 tFAWminUpper : 4; ///< Bits 3:0
UINT8 Reserved : 4; ///< Bits 7:4
} Bits;
UINT8 Data;
} SPD3_TFAW_MIN_MTB_UPPER_STRUCT;
typedef union {
struct {
UINT8 tFAWmin : 8; ///< Bits 7:0
} Bits;
UINT8 Data;
} SPD3_TFAW_MIN_MTB_STRUCT;
typedef union {
struct {
UINT8 Rzq6 : 1; ///< Bits 0:0
UINT8 Rzq7 : 1; ///< Bits 1:1
UINT8 Reserved : 5; ///< Bits 6:2
UINT8 DllOff : 1; ///< Bits 7:7
} Bits;
UINT8 Data;
} SPD3_SDRAM_OPTIONAL_FEATURES_STRUCT;
typedef union {
struct {
UINT8 ExtendedTemperatureRange : 1; ///< Bits 0:0
UINT8 ExtendedTemperatureRefreshRate : 1; ///< Bits 1:1
UINT8 AutoSelfRefresh : 1; ///< Bits 2:2
UINT8 OnDieThermalSensor : 1; ///< Bits 3:3
UINT8 Reserved : 3; ///< Bits 6:4
UINT8 PartialArraySelfRefresh : 1; ///< Bits 7:7
} Bits;
UINT8 Data;
} SPD3_SDRAM_THERMAL_REFRESH_STRUCT;
typedef union {
struct {
UINT8 ThermalSensorAccuracy : 7; ///< Bits 6:0
UINT8 ThermalSensorPresence : 1; ///< Bits 7:7
} Bits;
UINT8 Data;
} SPD3_MODULE_THERMAL_SENSOR_STRUCT;
typedef union {
struct {
UINT8 SignalLoading : 2; ///< Bits 1:0
UINT8 Reserved : 2; ///< Bits 3:2
UINT8 DieCount : 3; ///< Bits 6:4
UINT8 SdramDeviceType : 1; ///< Bits 7:7
} Bits;
UINT8 Data;
} SPD3_SDRAM_DEVICE_TYPE_STRUCT;
typedef union {
struct {
INT8 tCKminFine : 8; ///< Bits 7:0
} Bits;
INT8 Data;
} SPD3_TCK_MIN_FTB_STRUCT;
typedef union {
struct {
INT8 tAAminFine : 8; ///< Bits 7:0
} Bits;
INT8 Data;
} SPD3_TAA_MIN_FTB_STRUCT;
typedef union {
struct {
INT8 tRCDminFine : 8; ///< Bits 7:0
} Bits;
INT8 Data;
} SPD3_TRCD_MIN_FTB_STRUCT;
typedef union {
struct {
INT8 tRPminFine : 8; ///< Bits 7:0
} Bits;
INT8 Data;
} SPD3_TRP_MIN_FTB_STRUCT;
typedef union {
struct {
INT8 tRCminFine : 8; ///< Bits 7:0
} Bits;
INT8 Data;
} SPD3_TRC_MIN_FTB_STRUCT;
typedef union {
struct {
UINT8 MaximumActivateCount : 4; ///< Bits 3:0
UINT8 MaximumActivateWindow : 2; ///< Bits 5:4
UINT8 VendorSpecific : 2; ///< Bits 7:6
} Bits;
UINT8 Data;
} SPD3_MAXIMUM_ACTIVE_COUNT_STRUCT;
typedef union {
struct {
UINT8 Height : 5; ///< Bits 4:0
UINT8 RawCardExtension : 3; ///< Bits 7:5
} Bits;
UINT8 Data;
} SPD3_UNBUF_MODULE_NOMINAL_HEIGHT;
typedef union {
struct {
UINT8 FrontThickness : 4; ///< Bits 3:0
UINT8 BackThickness : 4; ///< Bits 7:4
} Bits;
UINT8 Data;
} SPD3_UNBUF_MODULE_NOMINAL_THICKNESS;
typedef union {
struct {
UINT8 Card : 5; ///< Bits 4:0
UINT8 Revision : 2; ///< Bits 6:5
UINT8 Extension : 1; ///< Bits 7:7
} Bits;
UINT8 Data;
} SPD3_UNBUF_REFERENCE_RAW_CARD;
typedef union {
struct {
UINT8 MappingRank1 : 1; ///< Bits 0:0
UINT8 Reserved : 7; ///< Bits 7:1
} Bits;
UINT8 Data;
} SPD3_UNBUF_ADDRESS_MAPPING;
typedef union {
struct {
UINT8 Height : 5; ///< Bits 4:0
UINT8 Reserved : 3; ///< Bits 7:5
} Bits;
UINT8 Data;
} SPD3_RDIMM_MODULE_NOMINAL_HEIGHT;
typedef union {
struct {
UINT8 FrontThickness : 4; ///< Bits 3:0
UINT8 BackThickness : 4; ///< Bits 7:4
} Bits;
UINT8 Data;
} SPD3_RDIMM_MODULE_NOMINAL_THICKNESS;
typedef union {
struct {
UINT8 Card : 5; ///< Bits 4:0
UINT8 Revision : 2; ///< Bits 6:5
UINT8 Extension : 1; ///< Bits 7:7
} Bits;
UINT8 Data;
} SPD3_RDIMM_REFERENCE_RAW_CARD;
typedef union {
struct {
UINT8 RegisterCount : 2; ///< Bits 1:0
UINT8 DramRowCount : 2; ///< Bits 3:2
UINT8 RegisterType : 4; ///< Bits 7:4
} Bits;
UINT8 Data;
} SPD3_RDIMM_MODULE_ATTRIBUTES;
typedef union {
struct {
UINT8 HeatSpreaderThermalCharacteristics : 7; ///< Bits 6:0
UINT8 HeatSpreaderSolution : 1; ///< Bits 7:7
} Bits;
UINT8 Data;
} SPD3_RDIMM_THERMAL_HEAT_SPREADER_SOLUTION;
typedef union {
struct {
UINT16 ContinuationCount : 7; ///< Bits 6:0
UINT16 ContinuationParity : 1; ///< Bits 7:7
UINT16 LastNonZeroByte : 8; ///< Bits 15:8
} Bits;
UINT16 Data;
UINT8 Data8[2];
} SPD3_MANUFACTURER_ID_CODE;
typedef union {
struct {
UINT8 RegisterRevisionNumber; ///< Bits 7:0
} Bits;
UINT8 Data;
} SPD3_RDIMM_REGISTER_REVISION_NUMBER;
typedef union {
struct {
UINT8 Bit0 : 1; ///< Bits 0:0
UINT8 Bit1 : 1; ///< Bits 1:1
UINT8 Bit2 : 1; ///< Bits 2:2
UINT8 Reserved : 5; ///< Bits 7:3
} Bits;
UINT8 Data;
} SPD3_RDIMM_REGISTER_TYPE;
typedef union {
struct {
UINT8 Reserved : 4; ///< Bits 0:3
UINT8 CommandAddressAOutputs : 2; ///< Bits 5:4
UINT8 CommandAddressBOutputs : 2; ///< Bits 7:6
} Bits;
UINT8 Data;
} SPD3_RDIMM_REGISTER_CONTROL_COMMAND_ADDRESS;
typedef union {
struct {
UINT8 ControlSignalsAOutputs : 2; ///< Bits 0:1
UINT8 ControlSignalsBOutputs : 2; ///< Bits 3:2
UINT8 Y1Y3ClockOutputs : 2; ///< Bits 5:4
UINT8 Y0Y2ClockOutputs : 2; ///< Bits 7:6
} Bits;
UINT8 Data;
} SPD3_RDIMM_REGISTER_CONTROL_CONTROL_CLOCK;
typedef union {
struct {
UINT8 Reserved0 : 4; ///< Bits 0:3
UINT8 Reserved1 : 4; ///< Bits 7:4
} Bits;
UINT8 Data;
} SPD3_RDIMM_REGISTER_CONTROL_RESERVED;
typedef union {
struct {
UINT8 Height : 5; ///< Bits 4:0
UINT8 Reserved : 3; ///< Bits 7:5
} Bits;
UINT8 Data;
} SPD3_LRDIMM_MODULE_NOMINAL_HEIGHT;
typedef union {
struct {
UINT8 FrontThickness : 4; ///< Bits 3:0
UINT8 BackThickness : 4; ///< Bits 7:4
} Bits;
UINT8 Data;
} SPD3_LRDIMM_MODULE_NOMINAL_THICKNESS;
typedef union {
struct {
UINT8 Card : 5; ///< Bits 4:0
UINT8 Revision : 2; ///< Bits 6:5
UINT8 Extension : 1; ///< Bits 7:7
} Bits;
UINT8 Data;
} SPD3_LRDIMM_REFERENCE_RAW_CARD;
typedef union {
struct {
UINT8 RegisterCount : 2; ///< Bits 1:0
UINT8 DramRowCount : 2; ///< Bits 3:2
UINT8 RegisterType : 4; ///< Bits 7:4
} Bits;
UINT8 Data;
} SPD3_LRDIMM_MODULE_ATTRIBUTES;
typedef union {
struct {
UINT8 AddressCommandPrelaunch : 1; ///< Bits 0:0
UINT8 Rank1Rank5Swap : 1; ///< Bits 1:1
UINT8 Reserved0 : 1; ///< Bits 2:2
UINT8 Reserved1 : 1; ///< Bits 3:3
UINT8 AddressCommandOutputs : 2; ///< Bits 5:4
UINT8 QxCS_nOutputs : 2; ///< Bits 7:6
} Bits;
UINT8 Data;
} SPD3_LRDIMM_TIMING_CONTROL_DRIVE_STRENGTH;
typedef union {
struct {
UINT8 QxOdtOutputs : 2; ///< Bits 1:0
UINT8 QxCkeOutputs : 2; ///< Bits 3:2
UINT8 Y1Y3ClockOutputs : 2; ///< Bits 5:4
UINT8 Y0Y2ClockOutputs : 2; ///< Bits 7:6
} Bits;
UINT8 Data;
} SPD3_LRDIMM_TIMING_DRIVE_STRENGTH;
typedef union {
struct {
UINT8 YExtendedDelay : 2; ///< Bits 1:0
UINT8 QxCS_n : 2; ///< Bits 3:2
UINT8 QxOdt : 2; ///< Bits 5:4
UINT8 QxCke : 2; ///< Bits 7:6
} Bits;
UINT8 Data;
} SPD3_LRDIMM_EXTENDED_DELAY;
typedef union {
struct {
UINT8 DelayY : 3; ///< Bits 2:0
UINT8 Reserved : 1; ///< Bits 3:3
UINT8 QxCS_n : 4; ///< Bits 7:4
} Bits;
UINT8 Data;
} SPD3_LRDIMM_ADDITIVE_DELAY_FOR_QXCS_N_QXCA;
typedef union {
struct {
UINT8 QxCS_n : 4; ///< Bits 3:0
UINT8 QxOdt : 4; ///< Bits 7:4
} Bits;
UINT8 Data;
} SPD3_LRDIMM_ADDITIVE_DELAY_FOR_QXODT_QXCKE;
typedef union {
struct {
UINT8 RC8MdqOdtStrength : 3; ///< Bits 2:0
UINT8 RC8Reserved : 1; ///< Bits 3:3
UINT8 RC9MdqOdtStrength : 3; ///< Bits 6:4
UINT8 RC9Reserved : 1; ///< Bits 7:7
} Bits;
UINT8 Data;
} SPD3_LRDIMM_MDQ_TERMINATION_DRIVE_STRENGTH;
typedef union {
struct {
UINT8 RC10DA3ValueR0 : 1; ///< Bits 0:0
UINT8 RC10DA4ValueR0 : 1; ///< Bits 1:1
UINT8 RC10DA3ValueR1 : 1; ///< Bits 2:2
UINT8 RC10DA4ValueR1 : 1; ///< Bits 3:3
UINT8 RC11DA3ValueR0 : 1; ///< Bits 4:4
UINT8 RC11DA4ValueR0 : 1; ///< Bits 5:5
UINT8 RC11DA3ValueR1 : 1; ///< Bits 6:6
UINT8 RC11DA4ValueR1 : 1; ///< Bits 7:7
} Bits;
UINT8 Data;
} SPD3_LRDIMM_RANK_READ_WRITE_QXODT_CONTROL;
typedef union {
struct {
UINT8 Driver_Impedance : 2; ///< Bits 1:0
UINT8 Rtt_Nom : 3; ///< Bits 4:2
UINT8 Reserved : 1; ///< Bits 5:5
UINT8 Rtt_WR : 2; ///< Bits 7:6
} Bits;
UINT8 Data;
} SPD3_LRDIMM_MR_1_2;
typedef union {
struct {
UINT8 MinimumDelayTime : 7; ///< Bits 0:6
UINT8 Reserved : 1; ///< Bits 7:7
} Bits;
UINT8 Data;
} SPD3_LRDIMM_MODULE_DELAY_TIME;
typedef struct {
UINT8 Year; ///< Year represented in BCD (00h = 2000)
UINT8 Week; ///< Year represented in BCD (47h = week 47)
} SPD3_MANUFACTURING_DATE;
typedef union {
UINT32 Data;
UINT16 SerialNumber16[2];
UINT8 SerialNumber8[4];
} SPD3_MANUFACTURER_SERIAL_NUMBER;
typedef struct {
UINT8 Location; ///< Module Manufacturing Location
} SPD3_MANUFACTURING_LOCATION;
typedef struct {
SPD3_MANUFACTURER_ID_CODE IdCode; ///< Module Manufacturer ID Code
SPD3_MANUFACTURING_LOCATION Location; ///< Module Manufacturing Location
SPD3_MANUFACTURING_DATE Date; ///< Module Manufacturing Year, in BCD (range: 2000-2255)
SPD3_MANUFACTURER_SERIAL_NUMBER SerialNumber; ///< Module Serial Number
} SPD3_UNIQUE_MODULE_ID;
typedef union {
UINT16 Crc[1];
UINT8 Data8[2];
} SPD3_CYCLIC_REDUNDANCY_CODE;
typedef struct {
SPD3_DEVICE_DESCRIPTION_STRUCT Description; ///< 0 Number of Serial PD Bytes Written / SPD Device Size / CRC Coverage 1, 2
SPD3_REVISION_STRUCT Revision; ///< 1 SPD Revision
SPD3_DRAM_DEVICE_TYPE_STRUCT DramDeviceType; ///< 2 DRAM Device Type
SPD3_MODULE_TYPE_STRUCT ModuleType; ///< 3 Module Type
SPD3_SDRAM_DENSITY_BANKS_STRUCT SdramDensityAndBanks; ///< 4 SDRAM Density and Banks
SPD3_SDRAM_ADDRESSING_STRUCT SdramAddressing; ///< 5 SDRAM Addressing
SPD3_MODULE_NOMINAL_VOLTAGE_STRUCT ModuleNominalVoltage; ///< 6 Module Nominal Voltage, VDD
SPD3_MODULE_ORGANIZATION_STRUCT ModuleOrganization; ///< 7 Module Organization
SPD3_MODULE_MEMORY_BUS_WIDTH_STRUCT ModuleMemoryBusWidth; ///< 8 Module Memory Bus Width
SPD3_FINE_TIMEBASE_STRUCT FineTimebase; ///< 9 Fine Timebase (FTB) Dividend / Divisor
SPD3_MEDIUM_TIMEBASE MediumTimebase; ///< 10-11 Medium Timebase (MTB) Dividend
SPD3_TCK_MIN_MTB_STRUCT tCKmin; ///< 12 SDRAM Minimum Cycle Time (tCKmin)
UINT8 Reserved0; ///< 13 Reserved
SPD3_CAS_LATENCIES_SUPPORTED_STRUCT CasLatencies; ///< 14-15 CAS Latencies Supported
SPD3_TAA_MIN_MTB_STRUCT tAAmin; ///< 16 Minimum CAS Latency Time (tAAmin)
SPD3_TWR_MIN_MTB_STRUCT tWRmin; ///< 17 Minimum Write Recovery Time (tWRmin)
SPD3_TRCD_MIN_MTB_STRUCT tRCDmin; ///< 18 Minimum RAS# to CAS# Delay Time (tRCDmin)
SPD3_TRRD_MIN_MTB_STRUCT tRRDmin; ///< 19 Minimum Row Active to Row Active Delay Time (tRRDmin)
SPD3_TRP_MIN_MTB_STRUCT tRPmin; ///< 20 Minimum Row Precharge Delay Time (tRPmin)
SPD3_TRAS_TRC_MIN_MTB_STRUCT tRASMintRCMinUpper; ///< 21 Upper Nibbles for tRAS and tRC
SPD3_TRAS_MIN_MTB_STRUCT tRASmin; ///< 22 Minimum Active to Precharge Delay Time (tRASmin), Least Significant Byte
SPD3_TRC_MIN_MTB_STRUCT tRCmin; ///< 23 Minimum Active to Active/Refresh Delay Time (tRCmin), Least Significant Byte
SPD3_TRFC_MIN_MTB_STRUCT tRFCmin; ///< 24-25 Minimum Refresh Recovery Delay Time (tRFCmin)
SPD3_TWTR_MIN_MTB_STRUCT tWTRmin; ///< 26 Minimum Internal Write to Read Command Delay Time (tWTRmin)
SPD3_TRTP_MIN_MTB_STRUCT tRTPmin; ///< 27 Minimum Internal Read to Precharge Command Delay Time (tRTPmin)
SPD3_TFAW_MIN_MTB_UPPER_STRUCT tFAWMinUpper; ///< 28 Upper Nibble for tFAW
SPD3_TFAW_MIN_MTB_STRUCT tFAWmin; ///< 29 Minimum Four Activate Window Delay Time (tFAWmin)
SPD3_SDRAM_OPTIONAL_FEATURES_STRUCT SdramOptionalFeatures; ///< 30 SDRAM Optional Features
SPD3_SDRAM_THERMAL_REFRESH_STRUCT ThermalAndRefreshOptions; ///< 31 SDRAM Thermal And Refresh Options
SPD3_MODULE_THERMAL_SENSOR_STRUCT ModuleThermalSensor; ///< 32 Module Thermal Sensor
SPD3_SDRAM_DEVICE_TYPE_STRUCT SdramDeviceType; ///< 33 SDRAM Device Type
SPD3_TCK_MIN_FTB_STRUCT tCKminFine; ///< 34 Fine Offset for SDRAM Minimum Cycle Time (tCKmin)
SPD3_TAA_MIN_FTB_STRUCT tAAminFine; ///< 35 Fine Offset for Minimum CAS Latency Time (tAAmin)
SPD3_TRCD_MIN_FTB_STRUCT tRCDminFine; ///< 36 Fine Offset for Minimum RAS# to CAS# Delay Time (tRCDmin)
SPD3_TRP_MIN_FTB_STRUCT tRPminFine; ///< 37 Minimum Row Precharge Delay Time (tRPmin)
SPD3_TRC_MIN_FTB_STRUCT tRCminFine; ///< 38 Fine Offset for Minimum Active to Active/Refresh Delay Time (tRCmin)
UINT8 Reserved1[40 - 39 + 1]; ///< 39 - 40 Reserved
SPD3_MAXIMUM_ACTIVE_COUNT_STRUCT MacValue; ///< 41 SDRAM Maximum Active Count (MAC) Value
UINT8 Reserved2[59 - 42 + 1]; ///< 42 - 59 Reserved
} SPD3_BASE_SECTION;
typedef struct {
SPD3_UNBUF_MODULE_NOMINAL_HEIGHT ModuleNominalHeight; ///< 60 Module Nominal Height
SPD3_UNBUF_MODULE_NOMINAL_THICKNESS ModuleMaximumThickness; ///< 61 Module Maximum Thickness
SPD3_UNBUF_REFERENCE_RAW_CARD ReferenceRawCardUsed; ///< 62 Reference Raw Card Used
SPD3_UNBUF_ADDRESS_MAPPING AddressMappingEdgeConn; ///< 63 Address Mapping from Edge Connector to DRAM
UINT8 Reserved[116 - 64 + 1]; ///< 64-116 Reserved
} SPD3_MODULE_UNBUFFERED;
typedef struct {
SPD3_RDIMM_MODULE_NOMINAL_HEIGHT ModuleNominalHeight; ///< 60 Module Nominal Height
SPD3_RDIMM_MODULE_NOMINAL_THICKNESS ModuleMaximumThickness; ///< 61 Module Maximum Thickness
SPD3_RDIMM_REFERENCE_RAW_CARD ReferenceRawCardUsed; ///< 62 Reference Raw Card Used
SPD3_RDIMM_MODULE_ATTRIBUTES DimmModuleAttributes; ///< 63 DIMM Module Attributes
SPD3_RDIMM_THERMAL_HEAT_SPREADER_SOLUTION ThermalHeatSpreaderSolution; ///< 64 RDIMM Thermal Heat Spreader Solution
SPD3_MANUFACTURER_ID_CODE RegisterManufacturerIdCode; ///< 65-66 Register Manufacturer ID Code
SPD3_RDIMM_REGISTER_REVISION_NUMBER RegisterRevisionNumber; ///< 67 Register Revision Number
SPD3_RDIMM_REGISTER_TYPE RegisterType; ///< 68 Register Type
SPD3_RDIMM_REGISTER_CONTROL_RESERVED Rc1Rc0; ///< 69 RC1 (MS Nibble) / RC0 (LS Nibble) - Reserved
SPD3_RDIMM_REGISTER_CONTROL_COMMAND_ADDRESS Rc3Rc2; ///< 70 RC3 (MS Nibble) / RC2 (LS Nibble) - Drive Strength, Command/Address
SPD3_RDIMM_REGISTER_CONTROL_CONTROL_CLOCK Rc5Rc4; ///< 71 RC5 (MS Nibble) / RC4 (LS Nibble) - Drive Strength, Control and Clock
SPD3_RDIMM_REGISTER_CONTROL_RESERVED Rc7Rc6; ///< 72 RC7 (MS Nibble) / RC6 (LS Nibble) - Reserved for Register Vendor
SPD3_RDIMM_REGISTER_CONTROL_RESERVED Rc9Rc8; ///< 73 RC9 (MS Nibble) / RC8 (LS Nibble) - Reserved
SPD3_RDIMM_REGISTER_CONTROL_RESERVED Rc11Rc10; ///< 74 RC11 (MS Nibble) / RC10 (LS Nibble) - Reserved
SPD3_RDIMM_REGISTER_CONTROL_RESERVED Rc13Rc12; ///< 75 RC12 (MS Nibble) / RC12 (LS Nibble) - Reserved
SPD3_RDIMM_REGISTER_CONTROL_RESERVED Rc15Rc14; ///< 76 RC15 (MS Nibble) / RC14 (LS Nibble) - Reserved
UINT8 Reserved[116 - 77 + 1]; ///< 77-116 Reserved
} SPD3_MODULE_REGISTERED;
typedef struct {
SPD3_UNBUF_MODULE_NOMINAL_HEIGHT ModuleNominalHeight; ///< 60 Module Nominal Height
SPD3_UNBUF_MODULE_NOMINAL_THICKNESS ModuleMaximumThickness; ///< 61 Module Maximum Thickness
SPD3_UNBUF_REFERENCE_RAW_CARD ReferenceRawCardUsed; ///< 62 Reference Raw Card Used
UINT8 Reserved[116 - 63 + 1]; ///< 63-116 Reserved
} SPD3_MODULE_CLOCKED;
typedef struct {
SPD3_LRDIMM_MODULE_NOMINAL_HEIGHT ModuleNominalHeight; ///< 60 Module Nominal Height
SPD3_LRDIMM_MODULE_NOMINAL_THICKNESS ModuleMaximumThickness; ///< 61 Module Maximum Thickness
SPD3_LRDIMM_REFERENCE_RAW_CARD ReferenceRawCardUsed; ///< 62 Reference Raw Card Used
SPD3_LRDIMM_MODULE_ATTRIBUTES DimmModuleAttributes; ///< 63 Module Attributes
UINT8 MemoryBufferRevisionNumber; ///< 64 Memory Buffer Revision Number
SPD3_MANUFACTURER_ID_CODE ManufacturerIdCode; ///< 65-66 Memory Buffer Manufacturer ID Code
SPD3_LRDIMM_TIMING_CONTROL_DRIVE_STRENGTH TimingControlDriveStrengthCaCs; ///< 67 F0RC3 / F0RC2 - Timing Control & Drive Strength, CA & CS
SPD3_LRDIMM_TIMING_DRIVE_STRENGTH DriveStrength; ///< 68 F0RC5 / F0RC4 - Drive Strength, ODT & CKE and Y
SPD3_LRDIMM_EXTENDED_DELAY ExtendedDelay; ///< 69 F1RC11 / F1RC8 - Extended Delay for Y, CS and ODT & CKE
SPD3_LRDIMM_ADDITIVE_DELAY_FOR_QXCS_N_QXCA AdditiveDelayForCsCa; ///< 70 F1RC13 / F1RC12 - Additive Delay for CS and CA
SPD3_LRDIMM_ADDITIVE_DELAY_FOR_QXODT_QXCKE AdditiveDelayForOdtCke; ///< 71 F1RC15 / F1RC14 - Additive Delay for ODT & CKE
SPD3_LRDIMM_MDQ_TERMINATION_DRIVE_STRENGTH MdqTerminationDriveStrengthFor800_1066; ///< 72 F1RC15 / F1RC14 - Additive Delay for ODT & CKE
SPD3_LRDIMM_RANK_READ_WRITE_QXODT_CONTROL Rank_0_1QxOdtControlFor800_1066; ///< 73 F[3,4]RC11 / F[3,4]RC10 - Rank 0 & 1 RD & WR QxODT Control for 800 & 1066
SPD3_LRDIMM_RANK_READ_WRITE_QXODT_CONTROL Rank_2_3QxOdtControlFor800_1066; ///< 74 F[5,6]RC11 / F[5,6]RC10 - Rank 2 & 3 RD & WR QxODT Control for 800 & 1066
SPD3_LRDIMM_RANK_READ_WRITE_QXODT_CONTROL Rank_4_5QxOdtControlFor800_1066; ///< 75 F[7,8]RC11 / F[7,8]RC10 - Rank 4 & 5 RD & WR QxODT Control for 800 & 1066
SPD3_LRDIMM_RANK_READ_WRITE_QXODT_CONTROL Rank_6_7QxOdtControlFor800_1066; ///< 76 F[9,10]RC11 / F[9,10]RC10 - Rank 6 & 7 RD & WR QxODT Control for 800 & 1066
SPD3_LRDIMM_MR_1_2 MR_1_2RegistersFor800_1066; ///< 77 MR1,2 Registers for 800 & 1066
SPD3_LRDIMM_MDQ_TERMINATION_DRIVE_STRENGTH MdqTerminationDriveStrengthFor1333_1600; ///< 78 F1RC15 / F1RC14 - Additive Delay for ODT & CKE
SPD3_LRDIMM_RANK_READ_WRITE_QXODT_CONTROL Rank_0_1QxOdtControlFor1333_1600; ///< 79 F[3,4]RC11 / F[3,4]RC10 - Rank 0 & 1 RD & WR QxODT Control for 800 & 1066
SPD3_LRDIMM_RANK_READ_WRITE_QXODT_CONTROL Rank_2_3QxOdtControlFor1333_1600; ///< 80 F[5,6]RC11 / F[5,6]RC10 - Rank 2 & 3 RD & WR QxODT Control for 800 & 1066
SPD3_LRDIMM_RANK_READ_WRITE_QXODT_CONTROL Rank_4_5QxOdtControlFor1333_1600; ///< 81 F[7,8]RC11 / F[7,8]RC10 - Rank 4 & 5 RD & WR QxODT Control for 800 & 1066
SPD3_LRDIMM_RANK_READ_WRITE_QXODT_CONTROL Rank_6_7QxOdtControlFor1333_1600; ///< 82 F[9,10]RC11 / F[9,10]RC10 - Rank 6 & 7 RD & WR QxODT Control for 800 & 1066
SPD3_LRDIMM_MR_1_2 MR_1_2RegistersFor1333_1600; ///< 83 MR1,2 Registers for 800 & 1066
SPD3_LRDIMM_MDQ_TERMINATION_DRIVE_STRENGTH MdqTerminationDriveStrengthFor1866_2133; ///< 84 F1RC15 / F1RC14 - Additive Delay for ODT & CKE
SPD3_LRDIMM_RANK_READ_WRITE_QXODT_CONTROL Rank_0_1QxOdtControlFor1866_2133; ///< 85 F[3,4]RC11 / F[3,4]RC10 - Rank 0 & 1 RD & WR QxODT Control for 800 & 1066
SPD3_LRDIMM_RANK_READ_WRITE_QXODT_CONTROL Rank_2_3QxOdtControlFor1866_2133; ///< 86 F[5,6]RC11 / F[5,6]RC10 - Rank 2 & 3 RD & WR QxODT Control for 800 & 1066
SPD3_LRDIMM_RANK_READ_WRITE_QXODT_CONTROL Rank_4_5QxOdtControlFor1866_2133; ///< 87 F[7,8]RC11 / F[7,8]RC10 - Rank 4 & 5 RD & WR QxODT Control for 800 & 1066
SPD3_LRDIMM_RANK_READ_WRITE_QXODT_CONTROL Rank_6_7QxOdtControlFor1866_2133; ///< 88 F[9,10]RC11 / F[9,10]RC10 - Rank 6 & 7 RD & WR QxODT Control for 800 & 1066
SPD3_LRDIMM_MR_1_2 MR_1_2RegistersFor1866_2133; ///< 89 MR1,2 Registers for 800 & 1066
SPD3_LRDIMM_MODULE_DELAY_TIME MinimumModuleDelayTimeFor1_5V; ///< 90 Minimum Module Delay Time for 1.5 V
SPD3_LRDIMM_MODULE_DELAY_TIME MaximumModuleDelayTimeFor1_5V; ///< 91 Maximum Module Delay Time for 1.5 V
SPD3_LRDIMM_MODULE_DELAY_TIME MinimumModuleDelayTimeFor1_35V; ///< 92 Minimum Module Delay Time for 1.35 V
SPD3_LRDIMM_MODULE_DELAY_TIME MaximumModuleDelayTimeFor1_35V; ///< 93 Maximum Module Delay Time for 1.35 V
SPD3_LRDIMM_MODULE_DELAY_TIME MinimumModuleDelayTimeFor1_25V; ///< 94 Minimum Module Delay Time for 1.25 V
SPD3_LRDIMM_MODULE_DELAY_TIME MaximumModuleDelayTimeFor1_25V; ///< 95 Maximum Module Delay Time for 1.25 V
UINT8 Reserved[101 - 96 + 1]; ///< 96-101 Reserved
UINT8 PersonalityByte[116 - 102 + 1]; ///< 102-116 Memory Buffer Personality Bytes
} SPD3_MODULE_LOADREDUCED;
typedef union {
SPD3_MODULE_UNBUFFERED Unbuffered; ///< 128-255 Unbuffered Memory Module Types
SPD3_MODULE_REGISTERED Registered; ///< 128-255 Registered Memory Module Types
SPD3_MODULE_CLOCKED Clocked; ///< 128-255 Registered Memory Module Types
SPD3_MODULE_LOADREDUCED LoadReduced; ///< 128-255 Load Reduced Memory Module Types
} SPD3_MODULE_SPECIFIC;
typedef struct {
UINT8 ModulePartNumber[145 - 128 + 1]; ///< 128-145 Module Part Number
} SPD3_MODULE_PART_NUMBER;
typedef struct {
UINT8 ModuleRevisionCode[147 - 146 + 1]; ///< 146-147 Module Revision Code
} SPD3_MODULE_REVISION_CODE;
typedef struct {
UINT8 ManufacturerSpecificData[175 - 150 + 1];///< 150-175 Manufacturer's Specific Data
} SPD3_MANUFACTURER_SPECIFIC;
///
/// DDR3 Serial Presence Detect structure
///
typedef struct {
SPD3_BASE_SECTION General; ///< 0-59 General Section
SPD3_MODULE_SPECIFIC Module; ///< 60-116 Module-Specific Section
SPD3_UNIQUE_MODULE_ID ModuleId; ///< 117-125 Unique Module ID
SPD3_CYCLIC_REDUNDANCY_CODE Crc; ///< 126-127 Cyclical Redundancy Code (CRC)
SPD3_MODULE_PART_NUMBER ModulePartNumber; ///< 128-145 Module Part Number
SPD3_MODULE_REVISION_CODE ModuleRevisionCode; ///< 146-147 Module Revision Code
SPD3_MANUFACTURER_ID_CODE DramIdCode; ///< 148-149 Dram Manufacturer ID Code
SPD3_MANUFACTURER_SPECIFIC ManufacturerSpecificData; ///< 150-175 Manufacturer's Specific Data
UINT8 Reserved[255 - 176 + 1]; ///< 176-255 Open for Customer Use
} SPD_DDR3;
#pragma pack (pop)
#endif