2015-02-04 19:22:51 +01:00
|
|
|
#
|
2018-01-29 14:11:11 +01:00
|
|
|
# Copyright 2018 Centreon (http://www.centreon.com/)
|
2015-07-21 11:51:02 +02:00
|
|
|
#
|
|
|
|
# Centreon is a full-fledged industry-strength solution that meets
|
|
|
|
# the needs in IT infrastructure and application monitoring for
|
|
|
|
# service performance.
|
|
|
|
#
|
|
|
|
# Licensed under the Apache License, Version 2.0 (the "License");
|
|
|
|
# you may not use this file except in compliance with the License.
|
|
|
|
# You may obtain a copy of the License at
|
|
|
|
#
|
|
|
|
# http://www.apache.org/licenses/LICENSE-2.0
|
|
|
|
#
|
|
|
|
# Unless required by applicable law or agreed to in writing, software
|
|
|
|
# distributed under the License is distributed on an "AS IS" BASIS,
|
|
|
|
# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
|
|
|
|
# See the License for the specific language governing permissions and
|
|
|
|
# limitations under the License.
|
|
|
|
#
|
2015-02-04 19:22:51 +01:00
|
|
|
|
|
|
|
package storage::emc::celerra::local::mode::getreason;
|
|
|
|
|
2016-10-07 17:23:02 +02:00
|
|
|
use base qw(centreon::plugins::templates::hardware);
|
2015-02-04 19:22:51 +01:00
|
|
|
|
|
|
|
use strict;
|
|
|
|
use warnings;
|
|
|
|
use centreon::plugins::misc;
|
|
|
|
|
2016-10-07 17:23:02 +02:00
|
|
|
sub set_system {
|
|
|
|
my ($self, %options) = @_;
|
|
|
|
|
|
|
|
$self->{regexp_threshold_overload_check_section_option} =
|
|
|
|
'^(controlstation|datamover)$';
|
|
|
|
|
|
|
|
$self->{cb_hook2} = 'cmd_execute';
|
|
|
|
|
|
|
|
$self->{thresholds} = {
|
|
|
|
controlstation => [
|
|
|
|
['Primary Control Station', 'OK'], # 10
|
|
|
|
['Secondary Control Station', 'OK'], # 11
|
|
|
|
['Control Station is ready, but is not running NAS service', 'CRITICAL'], # 6
|
|
|
|
],
|
|
|
|
datamover => [
|
|
|
|
['Reset (or unknown state)', 'WARNING'],
|
|
|
|
['DOS boot phase, BIOS check, boot sequence', 'WARNING'],
|
|
|
|
['SIB POST failures (that is, hardware failures)', 'CRITICAL'],
|
|
|
|
['DART is loaded on Data Mover, DOS boot and execution of boot.bat, boot.cfg', 'WARNING'],
|
|
|
|
['DART is ready on Data Mover, running, and MAC threads started', 'WARNING'],
|
|
|
|
['DART is in contact with Control Station box monitor', 'OK'],
|
|
|
|
['DART is in panic state', 'CRITICAL'],
|
|
|
|
['DART reboot is pending or in halted state', 'WARNING'],
|
|
|
|
['DART panicked and completed memory dump', 'CRITICAL'],
|
|
|
|
['DM Misc problems', 'CRITICAL'], # code 14
|
|
|
|
['Data Mover is flashing firmware. DART is flashing BIOS and/or POST firmware. Data Mover cannot be reset', 'CRITICAL'],
|
|
|
|
['Data Mover Hardware fault detected', 'CRITICAL'],
|
|
|
|
['DM Memory Test Failure. BIOS detected memory error', 'CRITICAL'],
|
|
|
|
['DM POST Test Failure. General POST error', 'CRITICAL'],
|
|
|
|
['DM POST NVRAM test failure. Invalid NVRAM content error', 'CRITICAL'],
|
|
|
|
['DM POST invalid peer Data Mover type', 'CRITICAL'],
|
|
|
|
['DM POST invalid Data Mover part number', 'CRITICAL'],
|
|
|
|
['DM POST Fibre Channel test failure. Error in blade Fibre connection', 'CRITICAL'],
|
|
|
|
['DM POST network test failure. Error in Ethernet controller', 'CRITICAL'],
|
|
|
|
['DM T2NET Error. Unable to get blade reason code due to management switch problems', 'CRITICAL'],
|
|
|
|
],
|
|
|
|
};
|
|
|
|
|
|
|
|
$self->{components_path} = 'storage::emc::celerra::local::mode::components';
|
|
|
|
$self->{components_module} = ['controlstation', 'datamover'];
|
|
|
|
}
|
|
|
|
|
|
|
|
sub cmd_execute {
|
|
|
|
my ($self, %options) = @_;
|
|
|
|
|
|
|
|
($self->{stdout}) = centreon::plugins::misc::execute(output => $self->{output},
|
|
|
|
options => $self->{option_results},
|
|
|
|
sudo => $self->{option_results}->{sudo},
|
|
|
|
command => $self->{option_results}->{command},
|
|
|
|
command_path => $self->{option_results}->{command_path},
|
|
|
|
command_options => $self->{option_results}->{command_options});
|
|
|
|
}
|
2015-02-04 19:22:51 +01:00
|
|
|
|
|
|
|
sub new {
|
|
|
|
my ($class, %options) = @_;
|
2016-10-07 17:23:02 +02:00
|
|
|
my $self = $class->SUPER::new(package => __PACKAGE__, %options, no_absent => 1, no_performance => 1);
|
2015-02-04 19:22:51 +01:00
|
|
|
bless $self, $class;
|
|
|
|
|
|
|
|
$self->{version} = '1.0';
|
|
|
|
$options{options}->add_options(arguments =>
|
|
|
|
{
|
|
|
|
"hostname:s" => { name => 'hostname' },
|
|
|
|
"remote" => { name => 'remote' },
|
|
|
|
"ssh-option:s@" => { name => 'ssh_option' },
|
|
|
|
"ssh-path:s" => { name => 'ssh_path' },
|
|
|
|
"ssh-command:s" => { name => 'ssh_command', default => 'ssh' },
|
|
|
|
"timeout:s" => { name => 'timeout', default => 30 },
|
|
|
|
"sudo" => { name => 'sudo' },
|
|
|
|
"command:s" => { name => 'command', default => 'getreason' },
|
|
|
|
"command-path:s" => { name => 'command_path', default => '/nas/sbin' },
|
|
|
|
"command-options:s" => { name => 'command_options', default => '2>&1' },
|
|
|
|
});
|
|
|
|
|
|
|
|
return $self;
|
|
|
|
}
|
|
|
|
|
|
|
|
1;
|
|
|
|
|
|
|
|
__END__
|
|
|
|
|
|
|
|
=head1 MODE
|
|
|
|
|
|
|
|
Check control stations and data movers status (use 'getreason' command).
|
|
|
|
|
|
|
|
=over 8
|
|
|
|
|
|
|
|
=item B<--component>
|
|
|
|
|
|
|
|
Which component to check (Default: '.*').
|
|
|
|
Can be: 'controlstation', 'datamover'.
|
|
|
|
|
2016-10-07 17:23:02 +02:00
|
|
|
=item B<--filter>
|
2015-02-04 19:22:51 +01:00
|
|
|
|
2016-10-07 17:23:02 +02:00
|
|
|
Exclude some parts (comma seperated list) (Example: --filter=datamover)
|
|
|
|
Can also exclude specific instance: --filter=datamover,slot_2
|
2015-02-04 19:22:51 +01:00
|
|
|
|
|
|
|
=item B<--no-component>
|
|
|
|
|
|
|
|
Return an error if no compenents are checked.
|
|
|
|
If total (with skipped) is 0. (Default: 'critical' returns).
|
|
|
|
|
|
|
|
=item B<--threshold-overload>
|
|
|
|
|
2016-10-07 17:23:02 +02:00
|
|
|
Set to overload default threshold values (syntax: section,[instance,]status,regexp)
|
2015-02-04 19:22:51 +01:00
|
|
|
It used before default thresholds (order stays).
|
|
|
|
Example: --threshold-overload='datamover,CRITICAL,^(?!(normal)$)'
|
|
|
|
|
|
|
|
=item B<--remote>
|
|
|
|
|
|
|
|
Execute command remotely in 'ssh'.
|
|
|
|
|
|
|
|
=item B<--hostname>
|
|
|
|
|
|
|
|
Hostname to query (need --remote).
|
|
|
|
|
|
|
|
=item B<--ssh-option>
|
|
|
|
|
|
|
|
Specify multiple options like the user (example: --ssh-option='-l=centreon-engine" --ssh-option='-p=52").
|
|
|
|
|
|
|
|
=item B<--ssh-path>
|
|
|
|
|
|
|
|
Specify ssh command path (default: none)
|
|
|
|
|
|
|
|
=item B<--ssh-command>
|
|
|
|
|
|
|
|
Specify ssh command (default: 'ssh'). Useful to use 'plink'.
|
|
|
|
|
|
|
|
=item B<--timeout>
|
|
|
|
|
|
|
|
Timeout in seconds for the command (Default: 30).
|
|
|
|
|
|
|
|
=item B<--sudo>
|
|
|
|
|
|
|
|
Use 'sudo' to execute the command.
|
|
|
|
|
|
|
|
=item B<--command>
|
|
|
|
|
|
|
|
Command to get information (Default: 'getreason').
|
|
|
|
Can be changed if you have output in a file.
|
|
|
|
|
|
|
|
=item B<--command-path>
|
|
|
|
|
|
|
|
Command path (Default: '/nas/sbin').
|
|
|
|
|
|
|
|
=item B<--command-options>
|
|
|
|
|
|
|
|
Command options (Default: '2>&1').
|
|
|
|
|
|
|
|
=back
|
|
|
|
|
|
|
|
=cut
|
|
|
|
|