diff --git a/centreon-plugins/hardware/server/dell/openmanage/mode/components/cachebattery.pm b/centreon-plugins/hardware/server/dell/openmanage/mode/components/cachebattery.pm new file mode 100644 index 000000000..375532c09 --- /dev/null +++ b/centreon-plugins/hardware/server/dell/openmanage/mode/components/cachebattery.pm @@ -0,0 +1,123 @@ +################################################################################ +# Copyright 2005-2013 MERETHIS +# Centreon is developped by : Julien Mathis and Romain Le Merlus under +# GPL Licence 2.0. +# +# This program is free software; you can redistribute it and/or modify it under +# the terms of the GNU General Public License as published by the Free Software +# Foundation ; either version 2 of the License. +# +# This program is distributed in the hope that it will be useful, but WITHOUT ANY +# WARRANTY; without even the implied warranty of MERCHANTABILITY or FITNESS FOR A +# PARTICULAR PURPOSE. See the GNU General Public License for more details. +# +# You should have received a copy of the GNU General Public License along with +# this program; if not, see . +# +# Linking this program statically or dynamically with other modules is making a +# combined work based on this program. Thus, the terms and conditions of the GNU +# General Public License cover the whole combination. +# +# As a special exception, the copyright holders of this program give MERETHIS +# permission to link this program with independent modules to produce an executable, +# regardless of the license terms of these independent modules, and to copy and +# distribute the resulting executable under terms of MERETHIS choice, provided that +# MERETHIS also meet, for each linked independent module, the terms and conditions +# of the license of that module. An independent module is a module which is not +# derived from this program. If you modify this program, you may extend this +# exception to your version of the program, but you are not obliged to do so. If you +# do not wish to do so, delete this exception statement from your version. +# +# For more information : contact@centreon.com +# Authors : Quentin Garnier +# +#################################################################################### + +package hardware::server::dell::openmanage::mode::components::cachebattery; + +use strict; +use warnings; + +my %state = ( + 0 => 'unknown', + 1 => 'ready', + 2 => 'failed', + 6 => 'degraded', + 7 => 'reconditioning', + 9 => 'high', + 10 => 'powerLow', + 12 => 'charging', + 21 => 'missing', + 36 => 'learning', +); + +my %componentStatus = ( + 1 => ['other', 'UNKNOWN'], + 2 => ['unknown', 'UNKNOWN'], + 3 => ['ok', 'OK'], + 4 => ['nonCritical', 'WARNING'], + 5 => ['critical', 'CRITICAL'], + 6 => ['nonRecoverable', 'CRITICAL'], +); + +my %learnState = ( + 1 => 'failed', + 2 => 'active', + 4 => 'timedOut', + 8 => 'requested', + 16 => 'idle', + 32 => 'due', +); + +my %predictedCapacity = ( + 1 => 'failed', + 2 => 'ready', + 4 => 'unknown', +); + +sub check { + my ($self) = @_; + + # In MIB '10893.mib' + $self->{output}->output_add(long_msg => "Checking cache batteries"); + $self->{components}->{cachebattery} = {name => 'cache batteries', total => 0}; + return if ($self->check_exclude('cachebattery')); + + my $oid_batteryState = '.1.3.6.1.4.1.674.10893.1.20.130.15.1.4'; + my $oid_batteryComponentStatus = '.1.3.6.1.4.1.674.10893.1.20.130.15.1.6'; + my $oid_batteryPredictedCapicity = '.1.3.6.1.4.1.674.10893.1.20.130.15.1.10'; + my $oid_batteryLearnState = '.1.3.6.1.4.1.674.10893.1.20.130.15.1.12'; + + my $result = $self->{snmp}->get_table(oid => $oid_batteryState); + return if (scalar(keys %$result) <= 0); + + $self->{snmp}->load(oids => [$oid_batteryComponentStatus, $oid_batteryPredictedCapicity, $oid_batteryLearnState], + instances => [keys %$result], + instance_regexp => '(\d+)$'); + my $result2 = $self->{snmp}->get_leef(); + return if (scalar(keys %$result2) <= 0); + + foreach my $key ($self->{snmp}->oid_lex_sort(keys %$result)) { + $key =~ /(\d+)$/; + my $battery_Index = $1; + + my $battery_State = $result->{$key}; + my $battery_ComponentStatus = $result2->{$oid_batteryComponentStatus . '.' . $battery_Index}; + my $battery_PredictedCapacity = $result2->{$oid_batteryPredictedCapicity . '.' . $battery_Index}; + my $battery_LearnState = $result2->{$oid_batteryLearnState . '.' . $battery_Index}; + + $self->{components}->{cachebattery}->{total}++; + $self->{output}->output_add(long_msg => sprintf("cache battery %d status is %s, state is %s, learn state is %s, predicted capacity is %s.", + $battery_Index, ${$componentStatus{$battery_ComponentStatus}}[0], $state{$battery_State}, + $learnState{$battery_LearnState}, $predictedCapacity{$battery_PredictedCapacity} + )); + if ($battery_ComponentStatus != 3) { + $self->{output}->output_add(severity => ${$componentStatus{$battery_ComponentStatus}}[1], + short_msg => sprintf("cache battery %d status is %s", + $battery_Index, ${$componentStatus{$battery_ComponentStatus}}[0])); + } + + } +} + +1; diff --git a/centreon-plugins/hardware/server/dell/openmanage/mode/components/psu.pm b/centreon-plugins/hardware/server/dell/openmanage/mode/components/psu.pm index 3a399adfe..c6d2ef273 100644 --- a/centreon-plugins/hardware/server/dell/openmanage/mode/components/psu.pm +++ b/centreon-plugins/hardware/server/dell/openmanage/mode/components/psu.pm @@ -88,7 +88,7 @@ sub check { my $oid_powerSupplyStatus = '.1.3.6.1.4.1.674.10892.1.600.12.1.5'; my $oid_powerSupplyType = '.1.3.6.1.4.1.674.10892.1.600.12.1.7'; my $oid_powerSupplySensorState = '.1.3.6.1.4.1.674.10892.1.600.12.1.11'; - my $oid_powerSupplyConfigurationErrorType = '1.3.6.1.4.1.674.10892.1.600.12.1.12'; + my $oid_powerSupplyConfigurationErrorType = '.1.3.6.1.4.1.674.10892.1.600.12.1.12'; my $result = $self->{snmp}->get_table(oid => $oid_powerSupplyStatus); return if (scalar(keys %$result) <= 0); diff --git a/centreon-plugins/hardware/server/dell/openmanage/mode/hardware.pm b/centreon-plugins/hardware/server/dell/openmanage/mode/hardware.pm index a31822f5a..f7089e6dc 100644 --- a/centreon-plugins/hardware/server/dell/openmanage/mode/hardware.pm +++ b/centreon-plugins/hardware/server/dell/openmanage/mode/hardware.pm @@ -45,6 +45,7 @@ use hardware::server::dell::openmanage::mode::components::fan; use hardware::server::dell::openmanage::mode::components::psu; use hardware::server::dell::openmanage::mode::components::temperature; use hardware::server::dell::openmanage::mode::components::cpu; +use hardware::server::dell::openmanage::mode::components::cachebattery; sub new { my ($class, %options) = @_; @@ -77,6 +78,7 @@ sub global { hardware::server::dell::openmanage::mode::components::psu::check($self); hardware::server::dell::openmanage::mode::components::temperature::check($self); hardware::server::dell::openmanage::mode::components::cpu::check($self); + hardware::server::dell::openmanage::mode::components::cachebattery::check($self); my $total_components = 0; my $display_by_component = ''; @@ -110,6 +112,8 @@ sub component { hardware::server::dell::openmanage::mode::components::temperature::check($self); } elsif ($self->{option_results}->{component} eq 'cpu') { hardware::server::dell::openmanage::mode::components::cpu::check($self); + } elsif ($self->{option_results}->{component} eq 'cachebattery') { + hardware::server::dell::openmanage::mode::components::cachebattery::check($self); }else { $self->{output}->add_option_msg(short_msg => "Wrong option. Cannot find component '" . $self->{option_results}->{component} . "'."); $self->{output}->option_exit(); @@ -175,14 +179,14 @@ __END__ =head1 MODE -Check Hardware (Global status, Fans, CPUs, Power Supplies, Temperature Probes). +Check Hardware (Global status, Fans, CPUs, Power Supplies, Temperature Probes, Cache Batteries). =over 8 =item B<--component> Which component to check (Default: 'all'). -Can be: 'globalstatus', 'fan', 'cpu', 'psu', 'temperature'. +Can be: 'globalstatus', 'fan', 'cpu', 'psu', 'temperature', 'cachebattery'. =item B<--exclude>