This commit is contained in:
garnier-quentin 2019-05-27 21:01:14 +02:00
parent 55c123de81
commit 6f565010ee

View File

@ -26,27 +26,27 @@ use warnings;
sub load {} sub load {}
my $bits_alarm = { my $bits_alarm = {
0 => 'at least two fans have been operating at less than 90% of their nominal speed for 5 minutes or more', 23 => 'at least two fans have been operating at less than 90% of their nominal speed for 5 minutes or more',
1 => 'the power supply fan has been operating at less than 90% of its nominal speed for 10 minutes or more, but less than 15 minutes', 22 => 'the power supply fan has been operating at less than 90% of its nominal speed for 10 minutes or more, but less than 15 minutes',
2 => 'the power supply fan has been operating at less than 90% of its nominal speed for 15 minutes or more', 21 => 'the power supply fan has been operating at less than 90% of its nominal speed for 15 minutes or more',
4 => 'cmgCpuTemp has exceeded its warning threshold', 19 => 'cmgCpuTemp has exceeded its warning threshold',
5 => 'mgDspTemp has exceeded its warning threshold', 18 => 'mgDspTemp has exceeded its warning threshold',
7 => 'Power On Status Test failure -NCE, QUICC test failures on power up', 16 => 'Power On Status Test failure -NCE, QUICC test failures on power up',
8 => 'The +5.1 v power supply to the MG processor is out of range', 15 => 'The +5.1 v power supply to the MG processor is out of range',
9 => 'The +3.3 v power supply to the VoIP complexes is out of range', 14 => 'The +3.3 v power supply to the VoIP complexes is out of range',
10 => 'The +3.3 v power supply to the VoIP complexes is out of range', 13 => 'The +3.3 v power supply to the VoIP complexes is out of range',
11 => 'The +1.58 v power supply to the DSP units is out of range', 12 => 'The +1.58 v power supply to the DSP units is out of range',
12 => 'The +2.5 v power supply to the 8260 processor is out of range', 11 => 'The +2.5 v power supply to the 8260 processor is out of range',
13 => 'The -48 v auxiliary power supply to the endpoints is out of range', 10 => 'The -48 v auxiliary power supply to the endpoints is out of range',
14 => 'The +12 v power supply to the fans is out of range', 9 => 'The +12 v power supply to the fans is out of range',
16 => 'Clock synchronization signal is lost', 7 => 'Clock synchronization signal is lost',
17 => 'Clock synchronization signal warning. Only one clock syncronization signal source remains', 6 => 'Clock synchronization signal warning. Only one clock syncronization signal source remains',
18 => 'Clock synchronization signal excessive switching', 5 => 'Clock synchronization signal excessive switching',
19 => 'TDM Test Expansion Box 1 Failure', 4 => 'TDM Test Expansion Box 1 Failure',
20 => 'TDM Test Expansion Box 2 Failure', 3 => 'TDM Test Expansion Box 2 Failure',
21 => 'PoE Power Supply Base Box Failure', 2 => 'PoE Power Supply Base Box Failure',
22 => 'PoE Power Supply Expansion Box 1 Failure', 1 => 'PoE Power Supply Expansion Box 1 Failure',
23 => 'PoE Power Supply Expansion Box 2 Failure', 0 => 'PoE Power Supply Expansion Box 2 Failure',
}; };
sub check { sub check {