Extend Dell server openmanage to add DiskSmartAlertIndication check
This commit is contained in:
parent
2b8bd82525
commit
81bf28229b
|
@ -72,6 +72,11 @@ my %componentStatus = (
|
|||
6 => ['nonRecoverable', 'CRITICAL'],
|
||||
);
|
||||
|
||||
my %smartAlertIndication = (
|
||||
1 => ['no', 'OK'],
|
||||
2 => ['yes', 'WARNING'],
|
||||
);
|
||||
|
||||
sub check {
|
||||
my ($self) = @_;
|
||||
|
||||
|
@ -85,11 +90,12 @@ sub check {
|
|||
my $oid_diskLengthInMB = '.1.3.6.1.4.1.674.10893.1.20.130.4.1.11';
|
||||
my $oid_diskSpareState = '.1.3.6.1.4.1.674.10893.1.20.130.4.1.22';
|
||||
my $oid_diskComponentStatus = '.1.3.6.1.4.1.674.10893.1.20.130.4.1.24';
|
||||
my $oid_diskSmartAlertIndication = '.1.3.6.1.4.1.674.10893.1.20.130.4.1.31';
|
||||
|
||||
my $result = $self->{snmp}->get_table(oid => $oid_diskName);
|
||||
return if (scalar(keys %$result) <= 0);
|
||||
|
||||
$self->{snmp}->load(oids => [$oid_diskState, $oid_diskLengthInMB, $oid_diskSpareState, $oid_diskComponentStatus],
|
||||
$self->{snmp}->load(oids => [$oid_diskState, $oid_diskLengthInMB, $oid_diskSpareState, $oid_diskComponentStatus, $oid_diskSmartAlertIndication],
|
||||
instances => [keys %$result],
|
||||
instance_regexp => '(\d+\.\d+)$');
|
||||
my $result2 = $self->{snmp}->get_leef();
|
||||
|
@ -105,16 +111,23 @@ sub check {
|
|||
my $disk_LengthInMB = $result2->{$oid_diskLengthInMB . '.' . $instance};
|
||||
my $disk_SpareState = $result2->{$oid_diskSpareState . '.' . $instance};
|
||||
my $disk_ComponentStatus = $result2->{$oid_diskComponentStatus . '.' . $instance};
|
||||
my $disk_SmartAlertIndication = $result2->{$oid_diskSmartAlertIndication . '.' . $instance};
|
||||
|
||||
$self->{components}->{physicaldisk}->{total}++;
|
||||
$self->{output}->output_add(long_msg => sprintf("physical disk %s status is %s, state is %s, spare state is %s, size is %d MB [index: %d].",
|
||||
$disk_Name, ${$componentStatus{$disk_ComponentStatus}}[0], $state{$disk_State},
|
||||
$self->{output}->output_add(long_msg => sprintf("physical disk '%s' status is %s, state is %s, predictive failure alert %s, spare state is %s, size is %d MB [index: %d].",
|
||||
$disk_Name, ${$componentStatus{$disk_ComponentStatus}}[0], $state{$disk_State}, ${$smartAlertIndication{$disk_SmartAlertIndication}}[0],
|
||||
$spareState{$disk_SpareState}, $disk_LengthInMB, $disk_Index
|
||||
));
|
||||
|
||||
if ($disk_SmartAlertIndication !=1) {
|
||||
$self->{output}->output_add(severity => ${$smartAlertIndication{$disk_SmartAlertIndication}}[1],
|
||||
short_msg => sprintf("physical disk '%s' has received a predictive failure alert [index: %d]",
|
||||
$disk_Name, $disk_Index));
|
||||
}
|
||||
|
||||
if ($disk_ComponentStatus != 3) {
|
||||
$self->{output}->output_add(severity => ${$componentStatus{$disk_ComponentStatus}}[1],
|
||||
short_msg => sprintf("physical disk %s status is %s [index: %d]",
|
||||
short_msg => sprintf("physical disk '%s' status is %s [index: %d]",
|
||||
$disk_Name, ${$componentStatus{$disk_ComponentStatus}}[0], $disk_Index));
|
||||
}
|
||||
|
||||
|
|
Loading…