diff --git a/centreon-plugins/hardware/pdu/apc/snmp/mode/components/humidity.pm b/centreon-plugins/hardware/pdu/apc/snmp/mode/components/humidity.pm index aa1225fa8..517ec7b56 100644 --- a/centreon-plugins/hardware/pdu/apc/snmp/mode/components/humidity.pm +++ b/centreon-plugins/hardware/pdu/apc/snmp/mode/components/humidity.pm @@ -86,7 +86,7 @@ sub check { } if (defined($result->{rPDU2SensorTempHumidityStatusRelativeHumidity}) && $result->{rPDU2SensorTempHumidityStatusRelativeHumidity} =~ /[0-9]/) { - my $value = $result->{rPDU2SensorTempHumidityStatusRelativeHumidity} / 10; + my $value = $result->{rPDU2SensorTempHumidityStatusRelativeHumidity}; my ($exit2, $warn, $crit, $checked) = $self->get_severity_numeric(section => 'humidity', instance => $result->{rPDU2SensorTempHumidityStatusNumber}, value => $value); if (!$self->{output}->is_status(value => $exit2, compare => 'ok', litteral => 1)) { $self->{output}->output_add(severity => $exit2, diff --git a/centreon-plugins/hardware/server/dell/idrac/snmp/mode/hardware.pm b/centreon-plugins/hardware/server/dell/idrac/snmp/mode/hardware.pm index e542b3346..cbaaa0b17 100644 --- a/centreon-plugins/hardware/server/dell/idrac/snmp/mode/hardware.pm +++ b/centreon-plugins/hardware/server/dell/idrac/snmp/mode/hardware.pm @@ -83,7 +83,7 @@ sub set_system { 'slot', 'fru', 'storagectrl', 'storagebattery', 'pdisk', 'vdisk']; $self->{regexp_threshold_overload_check_section_option} = - '^(' . join('|', @{$self->{components_module}}). ')$'; + '^(?:' . join('|', @{$self->{components_module}}). ')\.(?:status|state)$'; } sub snmp_execute {