From 991f1b5145b1a66b46ac700f2aa4bddf24c98545 Mon Sep 17 00:00:00 2001 From: garnier-quentin Date: Mon, 27 May 2019 21:01:14 +0200 Subject: [PATCH] Fix #1522 --- .../snmp/mode/components/alarm.pm | 42 +++++++++---------- 1 file changed, 21 insertions(+), 21 deletions(-) diff --git a/centreon-plugins/hardware/telephony/avaya/mediagateway/snmp/mode/components/alarm.pm b/centreon-plugins/hardware/telephony/avaya/mediagateway/snmp/mode/components/alarm.pm index 2423529f8..d0ac7f4f6 100644 --- a/centreon-plugins/hardware/telephony/avaya/mediagateway/snmp/mode/components/alarm.pm +++ b/centreon-plugins/hardware/telephony/avaya/mediagateway/snmp/mode/components/alarm.pm @@ -26,27 +26,27 @@ use warnings; sub load {} my $bits_alarm = { - 0 => 'at least two fans have been operating at less than 90% of their nominal speed for 5 minutes or more', - 1 => 'the power supply fan has been operating at less than 90% of its nominal speed for 10 minutes or more, but less than 15 minutes', - 2 => 'the power supply fan has been operating at less than 90% of its nominal speed for 15 minutes or more', - 4 => 'cmgCpuTemp has exceeded its warning threshold', - 5 => 'mgDspTemp has exceeded its warning threshold', - 7 => 'Power On Status Test failure -NCE, QUICC test failures on power up', - 8 => 'The +5.1 v power supply to the MG processor is out of range', - 9 => 'The +3.3 v power supply to the VoIP complexes is out of range', - 10 => 'The +3.3 v power supply to the VoIP complexes is out of range', - 11 => 'The +1.58 v power supply to the DSP units is out of range', - 12 => 'The +2.5 v power supply to the 8260 processor is out of range', - 13 => 'The -48 v auxiliary power supply to the endpoints is out of range', - 14 => 'The +12 v power supply to the fans is out of range', - 16 => 'Clock synchronization signal is lost', - 17 => 'Clock synchronization signal warning. Only one clock syncronization signal source remains', - 18 => 'Clock synchronization signal excessive switching', - 19 => 'TDM Test Expansion Box 1 Failure', - 20 => 'TDM Test Expansion Box 2 Failure', - 21 => 'PoE Power Supply Base Box Failure', - 22 => 'PoE Power Supply Expansion Box 1 Failure', - 23 => 'PoE Power Supply Expansion Box 2 Failure', + 23 => 'at least two fans have been operating at less than 90% of their nominal speed for 5 minutes or more', + 22 => 'the power supply fan has been operating at less than 90% of its nominal speed for 10 minutes or more, but less than 15 minutes', + 21 => 'the power supply fan has been operating at less than 90% of its nominal speed for 15 minutes or more', + 19 => 'cmgCpuTemp has exceeded its warning threshold', + 18 => 'mgDspTemp has exceeded its warning threshold', + 16 => 'Power On Status Test failure -NCE, QUICC test failures on power up', + 15 => 'The +5.1 v power supply to the MG processor is out of range', + 14 => 'The +3.3 v power supply to the VoIP complexes is out of range', + 13 => 'The +3.3 v power supply to the VoIP complexes is out of range', + 12 => 'The +1.58 v power supply to the DSP units is out of range', + 11 => 'The +2.5 v power supply to the 8260 processor is out of range', + 10 => 'The -48 v auxiliary power supply to the endpoints is out of range', + 9 => 'The +12 v power supply to the fans is out of range', + 7 => 'Clock synchronization signal is lost', + 6 => 'Clock synchronization signal warning. Only one clock syncronization signal source remains', + 5 => 'Clock synchronization signal excessive switching', + 4 => 'TDM Test Expansion Box 1 Failure', + 3 => 'TDM Test Expansion Box 2 Failure', + 2 => 'PoE Power Supply Base Box Failure', + 1 => 'PoE Power Supply Expansion Box 1 Failure', + 0 => 'PoE Power Supply Expansion Box 2 Failure', }; sub check {