centreon-plugins
|
|
||||||
================
|
|
||||||
|
|
||||||
Centreon Plugins is a repository and framework in order to simplify the monitoring plateform administrator.
|
|
||||||
Plugin dvelopment is now realy simple and everybody can now easily contribute in order to build the most exteneded library of plugins.
|
|
||||||
|
|
||||||
|
|
||||||
Catalogue
|
|
||||||
---------
|
|
||||||
|
|
||||||
Todo
|
|
||||||
|
|
||||||
Installation Instructions
|
|
||||||
-------------------------
|
|
||||||
|
|
||||||
Todo
|
|
||||||
|
|
||||||
|
|
||||||
Licence
|
|
||||||
-------
|
|
||||||
|
|
||||||
Todo
|
|
||||||
|
|
||||||
|
Read 'docs/user_guide.rst' for help or go to http://documentation.centreon.com/xxxx
|
||||||
|
|
|
@ -0,0 +1,435 @@
|
||||||
|
==========
|
||||||
|
User Guide
|
||||||
|
==========
|
||||||
|
|
||||||
|
-----------
|
||||||
|
Description
|
||||||
|
-----------
|
||||||
|
|
||||||
|
"centreon-plugins" is a free and open source project to monitor systems.
|
||||||
|
The project can be used with Centreon, Icinga and all monitoring softwares compatible nagios plugins.
|
||||||
|
|
||||||
|
The lastest version is available on following git repository: http://git.centreon.com/centreon-plugins.git
|
||||||
|
|
||||||
|
------------
|
||||||
|
Installation
|
||||||
|
------------
|
||||||
|
|
||||||
|
Debian Wheezy
|
||||||
|
^^^^^^^^^^^^^
|
||||||
|
|
||||||
|
Get the last version of "centreon-plugins" from the repository:
|
||||||
|
::
|
||||||
|
|
||||||
|
# aptitude install git
|
||||||
|
# git clone http://git.centreon.com/centreon-plugins.git
|
||||||
|
|
||||||
|
To monitor SNMP systems, you need to install the following packages:
|
||||||
|
::
|
||||||
|
|
||||||
|
# aptitude install perl libsnmp-perl
|
||||||
|
|
||||||
|
You can install other packages to use more plugins:
|
||||||
|
::
|
||||||
|
|
||||||
|
# aptitude install libxml-libxml-perl libjson-perl libwww-perl libxml-xpath-perl libnet-telnet-perl libnet-ntp-perl libnet-dns-perl libdbi-perl libdbd-mysql-perl libdbd-pg-perl
|
||||||
|
|
||||||
|
To use 'memcached' functionnality, you need to install the following CPAN module (no debian package): http://search.cpan.org/~wolfsage/Memcached-libmemcached-1.001702/libmemcached.pm
|
||||||
|
|
||||||
|
Centos/Rhel 6
|
||||||
|
^^^^^^^^^^^^^
|
||||||
|
|
||||||
|
Get the last version of "centreon-plugins" from the repository:
|
||||||
|
::
|
||||||
|
|
||||||
|
# yum install git
|
||||||
|
# git clone http://git.centreon.com/centreon-plugins.git
|
||||||
|
|
||||||
|
To monitor SNMP systems, you need to install the following packages:
|
||||||
|
::
|
||||||
|
|
||||||
|
# yum install perl net-snmp-perl
|
||||||
|
|
||||||
|
You can install other packages to use more plugins:
|
||||||
|
::
|
||||||
|
|
||||||
|
# yum install perl-XML-LibXML perl-JSON perl-libwww-perl perl-XML-XPath perl-Net-Telnet perl-Net-DNS perl-DBI perl-DBD-MySQL perl-DBD-Pg
|
||||||
|
|
||||||
|
To use 'memcached' functionnality, you need to install the following CPAN module (package available in 'rpmforge'): http://search.cpan.org/~wolfsage/Memcached-libmemcached-1.001702/libmemcached.pm
|
||||||
|
|
||||||
|
-----------
|
||||||
|
Basic Usage
|
||||||
|
-----------
|
||||||
|
|
||||||
|
We'll use a basic example to show you how to monitor a system. I have finished the install section and i want to monitor a Linux in SNMP.
|
||||||
|
First, i need to find the plugin to use in the list:
|
||||||
|
::
|
||||||
|
|
||||||
|
$ perl centreon_plugins.pl --list-plugin | grep -i linux | grep 'PLUGIN'
|
||||||
|
PLUGIN: os::linux::local::plugin
|
||||||
|
PLUGIN: os::linux::snmp::plugin
|
||||||
|
|
||||||
|
It seems that 'os::linux::snmp::plugin' is the good one. So i verify with the option ``--help`` to be sure:
|
||||||
|
::
|
||||||
|
|
||||||
|
$ perl centreon_plugins.pl --plugin=os::linux::snmp::plugin --help
|
||||||
|
...
|
||||||
|
Plugin Description:
|
||||||
|
Check Linux operating systems in SNMP.
|
||||||
|
|
||||||
|
It's exactly what i need. Now i'll the option ``--list-mode`` to know what can i do with it:
|
||||||
|
::
|
||||||
|
|
||||||
|
$ perl centreon_plugins.pl --plugin=os::linux::snmp::plugin --list-mode
|
||||||
|
...
|
||||||
|
Modes Available:
|
||||||
|
processcount
|
||||||
|
time
|
||||||
|
list-storages
|
||||||
|
disk-usage
|
||||||
|
diskio
|
||||||
|
uptime
|
||||||
|
swap
|
||||||
|
cpu-detailed
|
||||||
|
load
|
||||||
|
traffic
|
||||||
|
cpu
|
||||||
|
inodes
|
||||||
|
list-diskspath
|
||||||
|
list-interfaces
|
||||||
|
packet-errors
|
||||||
|
memory
|
||||||
|
tcpcon
|
||||||
|
storage
|
||||||
|
|
||||||
|
I would like to test the 'load' mode:
|
||||||
|
::
|
||||||
|
|
||||||
|
$ perl centreon_plugins.pl --plugin=os::linux::snmp::plugin --mode=load
|
||||||
|
UNKNOWN: Missing parameter --hostname.
|
||||||
|
|
||||||
|
It's not working because some options are missing. I can have a description of the mode and options with the option ``--help``:
|
||||||
|
::
|
||||||
|
|
||||||
|
$ perl centreon_plugins.pl --plugin=os::linux::snmp::plugin --mode=load --help
|
||||||
|
|
||||||
|
Eventually, i have to configure some SNMP options:
|
||||||
|
::
|
||||||
|
|
||||||
|
$ perl centreon_plugins.pl --plugin=os::linux::snmp::plugin --mode=load --hostname=127.0.0.1 --snmp-version=2c --snmp-community=public
|
||||||
|
OK: Load average: 0.00, 0.00, 0.00 | 'load1'=0.00;;;0; 'load5'=0.00;;;0; 'load15'=0.00;;;0;
|
||||||
|
|
||||||
|
I can set threshold with options ``--warning`` and ``--critical``:
|
||||||
|
::
|
||||||
|
|
||||||
|
$ perl centreon_plugins.pl --plugin=os::linux::snmp::plugin --mode=load --hostname=127.0.0.1 --snmp-version=2c --snmp-community=public --warning=1,2,3 --critical=2,3,4
|
||||||
|
OK: Load average: 0.00, 0.00, 0.00 | 'load1'=0.00;0:1;0:2;0; 'load5'=0.00;0:2;0:3;0; 'load15'=0.00;0:3;0:4;0;
|
||||||
|
|
||||||
|
===
|
||||||
|
FAQ
|
||||||
|
===
|
||||||
|
|
||||||
|
--------------------
|
||||||
|
What can i monitor ?
|
||||||
|
--------------------
|
||||||
|
|
||||||
|
The option ``--list-plugin`` can be used to get the list of plugins and a short description.
|
||||||
|
|
||||||
|
Headers of the table mean:
|
||||||
|
|
||||||
|
* Transport: The check has internal options for the transport
|
||||||
|
* Protocol: what is used to get the monitoring datas
|
||||||
|
* Experimental: The check is still in development
|
||||||
|
|
||||||
|
+-------------+--------------------+----------------------------+--------------------------------------------+--------------+-------------------------------------------------------------+
|
||||||
|
| | | Transport | Protocol | | |
|
||||||
|
| Category | Check +-------+----------+---------+--------+--------+-------+-------+----------+ Experimental | Comment |
|
||||||
|
| | | ssh | telnet | wsman | snmp | http | wmi | jmx | custom | | |
|
||||||
|
+=============+====================+=======+==========+=========+========+========+=======+=======+==========+==============+=============================================================+
|
||||||
|
| | Active Directory | | | | | | | | * | | Use 'dcdiag' command. Must be installed on Windows. |
|
||||||
|
| +--------------------+-------+----------+---------+--------+--------+-------+-------+----------+--------------+-------------------------------------------------------------+
|
||||||
|
| | Apache | | | | | * | | | | | Need Apache 'mod_status' module. |
|
||||||
|
| +--------------------+-------+----------+---------+--------+--------+-------+-------+----------+--------------+-------------------------------------------------------------+
|
||||||
|
| | Apc | | | | | * | | | | | |
|
||||||
|
| +--------------------+-------+----------+---------+--------+--------+-------+-------+----------+--------------+-------------------------------------------------------------+
|
||||||
|
| | Apcupsd | * | | | | | | | * | | Use 'apcupsd' commands. |
|
||||||
|
| +--------------------+-------+----------+---------+--------+--------+-------+-------+----------+--------------+-------------------------------------------------------------+
|
||||||
|
| | Bluemind | | | | | * | | | | | Use 'influxdb' API. |
|
||||||
|
| +--------------------+-------+----------+---------+--------+--------+-------+-------+----------+--------------+-------------------------------------------------------------+
|
||||||
|
| | Exchange | | | | | | | | * | | Use powershell script. Must be installed on Windows. |
|
||||||
|
| +--------------------+-------+----------+---------+--------+--------+-------+-------+----------+--------------+-------------------------------------------------------------+
|
||||||
|
| | Hddtemp | | | | | | | | * | | Open a TCP custom communication |
|
||||||
|
| +--------------------+-------+----------+---------+--------+--------+-------+-------+----------+--------------+-------------------------------------------------------------+
|
||||||
|
| | | | | | | | * | | | | Must be installed on Windows. |
|
||||||
|
| | IIS +-------+----------+---------+--------+--------+-------+-------+----------+--------------+-------------------------------------------------------------+
|
||||||
|
| Application | | | | * | | | * | | | * | |
|
||||||
|
| +--------------------+-------+----------+---------+--------+--------+-------+-------+----------+--------------+-------------------------------------------------------------+
|
||||||
|
| | Lmsensors | | | | * | | | | | | |
|
||||||
|
| +--------------------+-------+----------+---------+--------+--------+-------+-------+----------+--------------+-------------------------------------------------------------+
|
||||||
|
| | Msmq | | | | | | | | * | * | Must be installed on Windows. Not developed yet. |
|
||||||
|
| +--------------------+-------+----------+---------+--------+--------+-------+-------+----------+--------------+-------------------------------------------------------------+
|
||||||
|
| | Nginx | | | | | * | | | | | Need 'HttpStubStatusModule' module. |
|
||||||
|
| +--------------------+-------+----------+---------+--------+--------+-------+-------+----------+--------------+-------------------------------------------------------------+
|
||||||
|
| | Pacemaker | * | | | | | | | * | | Use 'crm_mon' command. |
|
||||||
|
| +--------------------+-------+----------+---------+--------+--------+-------+-------+----------+--------------+-------------------------------------------------------------+
|
||||||
|
| | Pfsense | | | | * | | | | | | |
|
||||||
|
| +--------------------+-------+----------+---------+--------+--------+-------+-------+----------+--------------+-------------------------------------------------------------+
|
||||||
|
| | Selenium | | | | | | | | * | | Connect to a selenium server to play a scenario. |
|
||||||
|
| +--------------------+-------+----------+---------+--------+--------+-------+-------+----------+--------------+-------------------------------------------------------------+
|
||||||
|
| | Tomcat | | | | | * | | | | | Need tomcat webmanager. |
|
||||||
|
| +--------------------+-------+----------+---------+--------+--------+-------+-------+----------+--------------+-------------------------------------------------------------+
|
||||||
|
| | Varnish | * | | | | | | | * | | Use varnish commands. |
|
||||||
|
| +--------------------+-------+----------+---------+--------+--------+-------+-------+----------+--------------+-------------------------------------------------------------+
|
||||||
|
| | VMWare | | | | | | | | * | | Need 'centreon_esxd' connector from Merethis. |
|
||||||
|
| +--------------------+-------+----------+---------+--------+--------+-------+-------+----------+--------------+-------------------------------------------------------------+
|
||||||
|
| | Pfsense | | | | * | | | | | | |
|
||||||
|
+-------------+--------------------+-------+----------+---------+--------+--------+-------+-------+----------+--------------+-------------------------------------------------------------+
|
||||||
|
| | Informix | | | | | | | | * | | |
|
||||||
|
| +--------------------+-------+----------+---------+--------+--------+-------+-------+----------+--------------+-------------------------------------------------------------+
|
||||||
|
| | MS SQL | | | | | | | | * | | |
|
||||||
|
| +--------------------+-------+----------+---------+--------+--------+-------+-------+----------+--------------+-------------------------------------------------------------+
|
||||||
|
| Database | MySQL | | | | | | | | * | | |
|
||||||
|
| +--------------------+-------+----------+---------+--------+--------+-------+-------+----------+--------------+-------------------------------------------------------------+
|
||||||
|
| | Oracle | | | | | | | | * | | |
|
||||||
|
| +--------------------+-------+----------+---------+--------+--------+-------+-------+----------+--------------+-------------------------------------------------------------+
|
||||||
|
| | Postgres | | | | | | | | * | | |
|
||||||
|
+-------------+--------------------+-------+----------+---------+--------+--------+-------+-------+----------+--------------+-------------------------------------------------------------+
|
||||||
|
| | ATS Apc | | | | * | | | | | * | |
|
||||||
|
| +--------------------+-------+----------+---------+--------+--------+-------+-------+----------+--------------+-------------------------------------------------------------+
|
||||||
|
| | PDU Apc | | | | * | | | | | * | |
|
||||||
|
| +--------------------+-------+----------+---------+--------+--------+-------+-------+----------+--------------+-------------------------------------------------------------+
|
||||||
|
| | PDU Eaton | | | | * | | | | | * | |
|
||||||
|
| +--------------------+-------+----------+---------+--------+--------+-------+-------+----------+--------------+-------------------------------------------------------------+
|
||||||
|
| | Standard Printers | | | | * | | | | | | |
|
||||||
|
| +--------------------+-------+----------+---------+--------+--------+-------+-------+----------+--------------+-------------------------------------------------------------+
|
||||||
|
| | Sensorip | | | | * | | | | | | |
|
||||||
|
| +--------------------+-------+----------+---------+--------+--------+-------+-------+----------+--------------+-------------------------------------------------------------+
|
||||||
|
| | Sensormetrix Em01 | | | | | * | | | | | |
|
||||||
|
| +--------------------+-------+----------+---------+--------+--------+-------+-------+----------+--------------+-------------------------------------------------------------+
|
||||||
|
| | Cisco UCS | | | | * | | | | | | |
|
||||||
|
| +--------------------+-------+----------+---------+--------+--------+-------+-------+----------+--------------+-------------------------------------------------------------+
|
||||||
|
| Hardware | Dell Openmanage | | | | * | | | | | | Need 'openmanage agent' on the operating system. |
|
||||||
|
| +--------------------+-------+----------+---------+--------+--------+-------+-------+----------+--------------+-------------------------------------------------------------+
|
||||||
|
| | HP Proliant | | | | * | | | | | | Need 'HP Insight agent' on the operating system. |
|
||||||
|
| +--------------------+-------+----------+---------+--------+--------+-------+-------+----------+--------------+-------------------------------------------------------------+
|
||||||
|
| | HP Blade Chassis | | | | * | | | | | | |
|
||||||
|
| +--------------------+-------+----------+---------+--------+--------+-------+-------+----------+--------------+-------------------------------------------------------------+
|
||||||
|
| | IBM HMC | * | | | | | | | * | * | |
|
||||||
|
| +--------------------+-------+----------+---------+--------+--------+-------+-------+----------+--------------+-------------------------------------------------------------+
|
||||||
|
| | IBM IMM | | | | * | | | | | | |
|
||||||
|
| +--------------------+-------+----------+---------+--------+--------+-------+-------+----------+--------------+-------------------------------------------------------------+
|
||||||
|
| | Sun hardware | * | * | | * | | | | * | | Can monitor many sun hardware. |
|
||||||
|
| +--------------------+-------+----------+---------+--------+--------+-------+-------+----------+--------------+-------------------------------------------------------------+
|
||||||
|
| | UPS Mge | | | | * | | | | | | |
|
||||||
|
| +--------------------+-------+----------+---------+--------+--------+-------+-------+----------+--------------+-------------------------------------------------------------+
|
||||||
|
| | UPS Standard | | | | * | | | | | | |
|
||||||
|
| +--------------------+-------+----------+---------+--------+--------+-------+-------+----------+--------------+-------------------------------------------------------------+
|
||||||
|
| | UPS Powerware | | | | * | | | | | | |
|
||||||
|
+-------------+--------------------+-------+----------+---------+--------+--------+-------+-------+----------+--------------+-------------------------------------------------------------+
|
||||||
|
| | Alcatel Omniswitch | | | | * | | | | | | |
|
||||||
|
| +--------------------+-------+----------+---------+--------+--------+-------+-------+----------+--------------+-------------------------------------------------------------+
|
||||||
|
| | Arkoon | | | | * | | | | | | |
|
||||||
|
| +--------------------+-------+----------+---------+--------+--------+-------+-------+----------+--------------+-------------------------------------------------------------+
|
||||||
|
| | Aruba | | | | * | | | | | | |
|
||||||
|
| +--------------------+-------+----------+---------+--------+--------+-------+-------+----------+--------------+-------------------------------------------------------------+
|
||||||
|
| | Bluecoat | | | | * | | | | | | |
|
||||||
|
| +--------------------+-------+----------+---------+--------+--------+-------+-------+----------+--------------+-------------------------------------------------------------+
|
||||||
|
| | Brocade | | | | * | | | | | | |
|
||||||
|
| +--------------------+-------+----------+---------+--------+--------+-------+-------+----------+--------------+-------------------------------------------------------------+
|
||||||
|
| | Checkpoint | | | | * | | | | | | |
|
||||||
|
| +--------------------+-------+----------+---------+--------+--------+-------+-------+----------+--------------+-------------------------------------------------------------+
|
||||||
|
| | Cisco | | | | * | | | | | | Many cisco (2800, Nexus,...) |
|
||||||
|
| +--------------------+-------+----------+---------+--------+--------+-------+-------+----------+--------------+-------------------------------------------------------------+
|
||||||
|
| | Citrix Netscaler | | | | * | | | | | | |
|
||||||
|
| +--------------------+-------+----------+---------+--------+--------+-------+-------+----------+--------------+-------------------------------------------------------------+
|
||||||
|
| | Dell Powerconnect | | | | * | | | | | | |
|
||||||
|
| +--------------------+-------+----------+---------+--------+--------+-------+-------+----------+--------------+-------------------------------------------------------------+
|
||||||
|
| Network | F5 Big-Ip | | | | * | | | | | | |
|
||||||
|
| +--------------------+-------+----------+---------+--------+--------+-------+-------+----------+--------------+-------------------------------------------------------------+
|
||||||
|
| | Fortinet Fortigate | | | | * | | | | | | |
|
||||||
|
| +--------------------+-------+----------+---------+--------+--------+-------+-------+----------+--------------+-------------------------------------------------------------+
|
||||||
|
| | Fritzbox | | | | * | | | | | | |
|
||||||
|
| +--------------------+-------+----------+---------+--------+--------+-------+-------+----------+--------------+-------------------------------------------------------------+
|
||||||
|
| | HP Procurve | | | | * | | | | | | |
|
||||||
|
| +--------------------+-------+----------+---------+--------+--------+-------+-------+----------+--------------+-------------------------------------------------------------+
|
||||||
|
| | Juniper | | | | * | | | | | | Can monitor 'SSG', 'SA', 'SRX' and 'MAG'. |
|
||||||
|
| +--------------------+-------+----------+---------+--------+--------+-------+-------+----------+--------------+-------------------------------------------------------------+
|
||||||
|
| | Palo Alto | | | | * | | | | | | |
|
||||||
|
| +--------------------+-------+----------+---------+--------+--------+-------+-------+----------+--------------+-------------------------------------------------------------+
|
||||||
|
| | Radware Alteon | | | | * | | | | | * | |
|
||||||
|
| +--------------------+-------+----------+---------+--------+--------+-------+-------+----------+--------------+-------------------------------------------------------------+
|
||||||
|
| | Ruggedcom | | | | * | | | | | | |
|
||||||
|
| +--------------------+-------+----------+---------+--------+--------+-------+-------+----------+--------------+-------------------------------------------------------------+
|
||||||
|
| | Securactive | | | | * | | | | | | |
|
||||||
|
| +--------------------+-------+----------+---------+--------+--------+-------+-------+----------+--------------+-------------------------------------------------------------+
|
||||||
|
| | Stonesoft | | | | * | | | | | | |
|
||||||
|
+-------------+--------------------+-------+----------+---------+--------+--------+-------+-------+----------+--------------+-------------------------------------------------------------+
|
||||||
|
| | | * | | | | | | | * | | Use AIX commands. |
|
||||||
|
| | AIX +-------+----------+---------+--------+--------+-------+-------+----------+--------------+-------------------------------------------------------------+
|
||||||
|
| | | | | | | | * | | | | |
|
||||||
|
| +--------------------+-------+----------+---------+--------+--------+-------+-------+----------+--------------+-------------------------------------------------------------+
|
||||||
|
| | Freebsd | | | | * | | | | | | Need 'bsnmpd' agent. |
|
||||||
|
| +--------------------+-------+----------+---------+--------+--------+-------+-------+----------+--------------+-------------------------------------------------------------+
|
||||||
|
| | | * | | | | | | | * | | Use Linux commands. |
|
||||||
|
| | Linux +-------+----------+---------+--------+--------+-------+-------+----------+--------------+-------------------------------------------------------------+
|
||||||
|
| Operating | | | | | * | | | | | | |
|
||||||
|
| System +--------------------+-------+----------+---------+--------+--------+-------+-------+----------+--------------+-------------------------------------------------------------+
|
||||||
|
| | Solaris | * | | | | | | | * | | Use solaris commands. |
|
||||||
|
| +--------------------+-------+----------+---------+--------+--------+-------+-------+----------+--------------+-------------------------------------------------------------+
|
||||||
|
| | | | | | * | | | | | | |
|
||||||
|
| | Windows +-------+----------+---------+--------+--------+-------+-------+----------+--------------+-------------------------------------------------------------+
|
||||||
|
| | | | | * | | | * | | | * | |
|
||||||
|
+-------------+--------------------+-------+----------+---------+--------+--------+-------+-------+----------+--------------+-------------------------------------------------------------+
|
||||||
|
| | Dell MD3000 | | | | | | | | * | | Need 'SMcli' command. |
|
||||||
|
| +--------------------+-------+----------+---------+--------+--------+-------+-------+----------+--------------+-------------------------------------------------------------+
|
||||||
|
| | Dell TL2000 | | | | * | | | | | | |
|
||||||
|
| +--------------------+-------+----------+---------+--------+--------+-------+-------+----------+--------------+-------------------------------------------------------------+
|
||||||
|
| | EMC Clariion | | | | | | | | * | | Need 'navisphere' command. |
|
||||||
|
| +--------------------+-------+----------+---------+--------+--------+-------+-------+----------+--------------+-------------------------------------------------------------+
|
||||||
|
| | EMC DataDomain | | | | * | | | | | | |
|
||||||
|
| +--------------------+-------+----------+---------+--------+--------+-------+-------+----------+--------------+-------------------------------------------------------------+
|
||||||
|
| | EMC Recoverypoint | * | | | | | | | * | | Use appliance commands. |
|
||||||
|
| +--------------------+-------+----------+---------+--------+--------+-------+-------+----------+--------------+-------------------------------------------------------------+
|
||||||
|
| | HP Lefthand | | | | * | | | | | | |
|
||||||
|
| +--------------------+-------+----------+---------+--------+--------+-------+-------+----------+--------------+-------------------------------------------------------------+
|
||||||
|
| | HP MSA2000 | | | | * | | | | | | |
|
||||||
|
| +--------------------+-------+----------+---------+--------+--------+-------+-------+----------+--------------+-------------------------------------------------------------+
|
||||||
|
| | HP p2000 | | | | | | * | | | | Use the XML API. |
|
||||||
|
| +--------------------+-------+----------+---------+--------+--------+-------+-------+----------+--------------+-------------------------------------------------------------+
|
||||||
|
| | IBM DS3000 | | | | | | | | * | | Use 'SMcli' command. |
|
||||||
|
| +--------------------+-------+----------+---------+--------+--------+-------+-------+----------+--------------+-------------------------------------------------------------+
|
||||||
|
| | IBM DS4000 | | | | | | | | * | | Use 'SMcli' command. |
|
||||||
|
| +--------------------+-------+----------+---------+--------+--------+-------+-------+----------+--------------+-------------------------------------------------------------+
|
||||||
|
| | IBM DS5000 | | | | | | | | * | | Use 'SMcli' command. |
|
||||||
|
| +--------------------+-------+----------+---------+--------+--------+-------+-------+----------+--------------+-------------------------------------------------------------+
|
||||||
|
| | IBM TS3100 | | | | * | | | | | | |
|
||||||
|
| +--------------------+-------+----------+---------+--------+--------+-------+-------+----------+--------------+-------------------------------------------------------------+
|
||||||
|
| | IBM TS3200 | | | | * | | | | | | |
|
||||||
|
| +--------------------+-------+----------+---------+--------+--------+-------+-------+----------+--------------+-------------------------------------------------------------+
|
||||||
|
| | Netapp | | | | * | | | | | | |
|
||||||
|
| +--------------------+-------+----------+---------+--------+--------+-------+-------+----------+--------------+-------------------------------------------------------------+
|
||||||
|
| | Qnap | | | | * | | | | | | |
|
||||||
|
| +--------------------+-------+----------+---------+--------+--------+-------+-------+----------+--------------+-------------------------------------------------------------+
|
||||||
|
| | Synology | | | | * | | | | | | |
|
||||||
|
| +--------------------+-------+----------+---------+--------+--------+-------+-------+----------+--------------+-------------------------------------------------------------+
|
||||||
|
| | Violin 3000 | | | | * | | | | | | |
|
||||||
|
+-------------+--------------------+-------+----------+---------+--------+--------+-------+-------+----------+--------------+-------------------------------------------------------------+
|
||||||
|
|
||||||
|
----------------------------
|
||||||
|
How can i remove perfdatas ?
|
||||||
|
----------------------------
|
||||||
|
|
||||||
|
For example, i check tcp connections from a linux in SNMP with following command:
|
||||||
|
::
|
||||||
|
|
||||||
|
$ perl centreon_plugins.pl --plugin=os::linux::snmp::plugin --mode=tcpcon --hostname=127.0.0.1 --snmp-version=2c --snmp-community=public
|
||||||
|
OK: Total connections: 1 | 'total'=1;;;0; 'con_closed'=0;;;0; 'con_closeWait'=0;;;0; ' con_synSent'=0;;;0; 'con_established'=1;;;0; 'con_timeWait'=0;;;0; 'con_lastAck'=0;;;0 ; 'con_listen'=5;;;0; 'con_synReceived'=0;;;0; 'con_finWait1'=0;;;0; 'con_finWait2'=0; ;;0; 'con_closing'=0;;;0;
|
||||||
|
|
||||||
|
There are too many perfdatas and i want to keep 'total' perfdata only. I use the option ``--filter-perfdata='total'``:
|
||||||
|
::
|
||||||
|
|
||||||
|
$ perl centreon_plugins.pl --plugin=os::linux::snmp::plugin --mode=tcpcon --hostname=127.0.0.1 --snmp-version=2c --snmp-community=public --filter-perfdata='total'
|
||||||
|
OK: Total connections: 1 | 'total'=1;;;0;
|
||||||
|
|
||||||
|
I can use regexp in ``--filter-perfdata`` option. So, i can exclude perfdata beginning by 'total':
|
||||||
|
::
|
||||||
|
|
||||||
|
$ perl centreon_plugins.pl --plugin=os::linux::snmp::plugin --mode=tcpcon --hostname=127.0.0.1 --snmp-version=2c --snmp-community=public --filter-perfdata='^(?!(total))'
|
||||||
|
OK: Total connections: 1 | 'con_closed'=0;;;0; 'con_closeWait'=0;;;0; 'con_synSent'=0;;;0; 'con_established'=1;;;0; 'con_timeWait'=0;;;0; 'con_lastAck'=0;;;0; 'con_listen'=5;;;0; 'con_synReceived'=0;;;0; 'con_finWait1'=0;;;0; 'con_finWait2'=0;;;0; 'con_closing'=0;;;0;
|
||||||
|
|
||||||
|
------------------------------------------------
|
||||||
|
How can i set threshold: critical if value < X ?
|
||||||
|
------------------------------------------------
|
||||||
|
|
||||||
|
"centreon-plugins" can manage nagios threshold ranges: https://nagios-plugins.org/doc/guidelines.html#THRESHOLDFORMAT
|
||||||
|
|
||||||
|
For example, i want to check that 'crond' is running (if there is less than 1 process, critical). I have two ways:
|
||||||
|
::
|
||||||
|
|
||||||
|
$ perl centreon_plugins.pl --plugin=os::linux::snmp::plugin --mode=processcount --hostname=127.0.0.1 --snmp-version=2c --snmp-community=public --process-name=crond --critical=1:
|
||||||
|
CRITICAL: Number of current processes running: 0 | 'nbproc'=0;;1:;0;
|
||||||
|
|
||||||
|
$ perl centreon_plugins.pl --plugin=os::linux::snmp::plugin --mode=processcount --hostname=127.0.0.1 --snmp-version=2c --snmp-community=public --process-name=crond --critical=@0:0
|
||||||
|
CRITICAL: Number of current processes running: 0 | 'nbproc'=0;;@0:0;0;
|
||||||
|
|
||||||
|
------------------------------------------
|
||||||
|
How can i check a generic SNMP OID value ?
|
||||||
|
------------------------------------------
|
||||||
|
|
||||||
|
There is a generic SNMP plugin to check it. An example to get 'SysUptime' SNMP OID:
|
||||||
|
::
|
||||||
|
|
||||||
|
$ perl centreon_plugins.pl --plugin=snmp_standard::plugin --mode=numeric-value --oid='.1.3.6.1.2.1.1.3.0' --hostname=127.0.0.1 --snmp-version=2c --snmp-community=public
|
||||||
|
|
||||||
|
===============
|
||||||
|
Troubleshooting
|
||||||
|
===============
|
||||||
|
|
||||||
|
----
|
||||||
|
SNMP
|
||||||
|
----
|
||||||
|
|
||||||
|
I get the SNMP error: 'UNKNOWN:.* (tooBig).*'
|
||||||
|
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
|
||||||
|
|
||||||
|
The following error can happened with some equipments.
|
||||||
|
You can resolve it if you set following options:
|
||||||
|
|
||||||
|
* ``--subsetleef=20`` ``--maxrepetitions=20``
|
||||||
|
|
||||||
|
I get the SNMP error: 'UNKNOWN:.*Timeout'
|
||||||
|
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
|
||||||
|
|
||||||
|
The following error means:
|
||||||
|
|
||||||
|
* Don't have network access to the target SNMP Server (a firewall can block UDP 161)
|
||||||
|
* Wrong SNMP community name or SNMP version set
|
||||||
|
|
||||||
|
I get the SNMP error: 'UNKNOWN:.*Cant get a single value'
|
||||||
|
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
|
||||||
|
|
||||||
|
The following error means: SNMP access is working but you can't retrieve SNMP values.
|
||||||
|
Very possible reasons:
|
||||||
|
|
||||||
|
* SNMP value is not set yet (can be happened when a snmp server is just started)
|
||||||
|
* SNMP value is not implemented by the constructor
|
||||||
|
* SNMP value is set on a specific Firmware or OS
|
||||||
|
|
||||||
|
Seems that process check is not working well for some arguments filter
|
||||||
|
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
|
||||||
|
|
||||||
|
In SNMP, there is a limit in argument length of 128 characters.
|
||||||
|
So, if you try to filter with an argument after 128 characters, it won't work. It can happen with java arguments.
|
||||||
|
To solve the problem, you should prefer a NRPE check.
|
||||||
|
|
||||||
|
Can't access in SNMP v3
|
||||||
|
^^^^^^^^^^^^^^^^^^^^^^^
|
||||||
|
|
||||||
|
First, you need to validate SNMP v3 connection with snmpwalk. When it's working, you set SNMP v3 options in command line.
|
||||||
|
The mapping between 'snmpwalk' options and centreon plugin options:
|
||||||
|
|
||||||
|
* -a => ``--authprotocol``
|
||||||
|
* -A => ``--authpassphrase``
|
||||||
|
* -u => ``--snmp-username``
|
||||||
|
* -x => ``--privprotocol``
|
||||||
|
* -X => ``--privpassphrase``
|
||||||
|
* -l => not needed (automatic)
|
||||||
|
* -e => ``--securityengineid``
|
||||||
|
* -E => ``--contextengineid``
|
||||||
|
|
||||||
|
-------------
|
||||||
|
Miscellaneous
|
||||||
|
-------------
|
||||||
|
|
||||||
|
I get the error: "UNKNOWN: Need to specify '--custommode'."
|
||||||
|
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
|
||||||
|
|
||||||
|
Some plugins need to set the option ``--custommode``. You can know the value to set with the option ``--list-custommode``. An example::
|
||||||
|
|
||||||
|
$ perl centreon_plugins.pl --plugin=storage::ibm::DS3000::cli::plugin --list-custommode
|
||||||
|
...
|
||||||
|
Custom Modes Available:
|
||||||
|
smcli
|
||||||
|
|
||||||
|
$ perl centreon_plugins.pl --plugin=storage::ibm::DS3000::cli::plugin --custommode=smcli --list-mode
|
||||||
|
|
Loading…