typo + add last time battery

This commit is contained in:
garnier-quentin 2020-01-28 15:03:44 +01:00
parent c412b8df89
commit c68d826375
2 changed files with 24 additions and 11 deletions

View File

@ -24,6 +24,7 @@ use base qw(centreon::plugins::templates::counter);
use strict;
use warnings;
use DateTime;
use centreon::plugins::templates::catalog_functions;
sub custom_status_output {
@ -66,7 +67,7 @@ sub set_counters {
closure_custom_threshold_check => \&centreon::plugins::templates::catalog_functions::catalog_status_threshold,
}
},
{ label => 'load', set => {
{ label => 'load', nlabel => 'battery.charge.remaining.percent', set => {
key_values => [ { name => 'upsAdvBatteryCapacity' } ],
output_template => 'remaining capacity: %s %%',
perfdatas => [
@ -75,7 +76,7 @@ sub set_counters {
],
}
},
{ label => 'time', set => {
{ label => 'time', nlabel => 'battery.charge.remaining.minutes', set => {
key_values => [ { name => 'upsAdvBatteryRunTimeRemaining' } ],
output_template => 'remaining time: %.2f minutes',
perfdatas => [
@ -84,7 +85,7 @@ sub set_counters {
],
}
},
{ label => 'current', set => {
{ label => 'current', nlabel => 'battery.current.ampere', set => {
key_values => [ { name => 'upsAdvBatteryCurrent' } ],
output_template => 'current: %s A',
perfdatas => [
@ -93,7 +94,7 @@ sub set_counters {
],
}
},
{ label => 'voltage', set => {
{ label => 'voltage', nlabel => 'battery.voltage.volt', set => {
key_values => [ { name => 'upsAdvBatteryActualVoltage' } ],
output_template => 'voltage: %s V',
perfdatas => [
@ -102,7 +103,7 @@ sub set_counters {
],
}
},
{ label => 'temperature', set => {
{ label => 'temperature', nlabel => 'battery.temperature.celsius', set => {
key_values => [ { name => 'upsAdvBatteryTemperature' } ],
output_template => 'temperature: %s C',
perfdatas => [
@ -111,6 +112,15 @@ sub set_counters {
],
}
},
{ label => 'replace-lasttime', nlabel => 'battery.replace.lasttime.seconds', display_ok => 0, set => {
key_values => [ { name => 'last_replace_time' } ],
output_template => 'replace last time: %s s',
perfdatas => [
{ label => 'temperature', value => 'last_replace_time_absolute', template => '%s',
unit => 's'},
],
}
}
];
}
@ -132,13 +142,11 @@ sub check_options {
my ($self, %options) = @_;
$self->SUPER::check_options(%options);
$self->change_macros(macros => ['warning_status', 'critical_status', 'unknown_status']);
$self->change_macros(macros => ['unknown_status', 'warning_status', 'critical_status']);
}
my $map_battery_status = {
1 => 'unknown',
2 => 'batteryNormal',
3 => 'batteryLow',
1 => 'unknown', 2 => 'batteryNormal', 3 => 'batteryLow'
};
my $map_replace_status = {
1 => 'no', 2 => 'yes'
@ -178,6 +186,10 @@ sub manage_selection {
$result2->{upsAdvBatteryRunTimeRemaining} = sprintf("%.0f", $result2->{upsAdvBatteryRunTimeRemaining} / 100 / 60)
if (defined($result2->{upsAdvBatteryRunTimeRemaining}));
$self->{global} = { %$result, %$result2 };
if (defined($result->{upsBasicBatteryLastReplaceDate}) && $result->{upsBasicBatteryLastReplaceDate} =~ /(\d{2})\/(\d{2})\/(\d{4})/) {
my $dt = DateTime->new(year => $3, month => $1, day => $2, hour => 0, minute => 0, second => 0);
$self->{global}->{last_replace_time} = time() - $dt->epoch;
}
}
1;
@ -213,7 +225,8 @@ Can used special variables like: %{status}, %{replace}
=item B<--warning-*> B<--critical-*>
Thresholds.
Can be: 'load', 'voltage', 'current', 'temperature', 'time'.
Can be: 'load', 'voltage', 'current',
'temperature', 'time', 'replace-lasttime'.
=back

View File

@ -49,7 +49,7 @@ sub set_counters {
closure_custom_threshold_check => \&catalog_status_threshold,
}
},
{ label => 'charge-remaining', , nlabel => 'battery.charge.remaining.percent', set => {
{ label => 'charge-remaining', nlabel => 'battery.charge.remaining.percent', set => {
key_values => [ { name => 'upsBatCapacity' } ],
output_template => 'remaining capacity: %s %%',
perfdatas => [