Commit Graph

676 Commits

Author SHA1 Message Date
Colin Gagnaire ad92e9ddbe
add cisco standard plugin configuration mode (#1236) 2018-11-23 15:55:43 +01:00
Colin Gagnaire 8a982c8fb8
fix cisco callmanager phone name oid, add description (#1231) 2018-11-20 14:07:04 +01:00
Colin Gagnaire 307d94012a
fix cisco callmanager phone name oid (#1230) 2018-11-20 10:42:04 +01:00
Colin Gagnaire 1172e6e09d
add mrv optiswitch plugin (#1215) 2018-11-08 16:13:50 +01:00
Colin Gagnaire df161b3d04
change masterclock plugin path (#1191) 2018-10-24 15:55:41 +02:00
Colin Gagnaire 340ecc112c
add moxa switch plugin (#1183) 2018-10-19 09:55:39 +02:00
Colin Gagnaire 7d60b30e1a
add masterclock ntp plugin (#1182) 2018-10-19 09:55:12 +02:00
Colin Gagnaire a10c543b8a enhance template counter (#1167)
* enh template counter, adapt modes not using the template

* rollback problems for type 2
2018-10-05 18:17:09 +02:00
Colin Gagnaire 964d9ba4c3 add ruckus smartcell gateway plugin (#1141) 2018-09-23 17:18:02 +02:00
Colin Gagnaire 510cb88579 add mitel 3300 icp plugin (#1146)
* add mitel 3300 icp plugin

* move to network tree
2018-09-20 10:06:07 +02:00
Colin Gagnaire 7434f86643 add barracuda cloudgen plugin (#1109) 2018-08-23 17:33:53 +02:00
Colin Gagnaire 6087f3b115 fix watchguard cpu usage calcul (#1106) 2018-08-22 11:58:56 +02:00
Colin Gagnaire 6e433f98fb enh h3c hardware mode to allow count thresholds (#1080)
* enh h3c hardware mode to allow count thresholds

* + use ternary operator
2018-08-16 17:14:10 +02:00
Colin Gagnaire 8974eb6775
enh paloalto cluster output (#1054) 2018-07-13 09:45:33 +02:00
Colin Gagnaire 1ea5724672
fix hirschmann memory (#1052) 2018-07-12 17:21:24 +02:00
Colin Gagnaire 44600ef825
fix fortigate devicestatus help (#1050) 2018-07-12 14:23:40 +02:00
Colin Gagnaire bd5e3567dc
enh h3c hardware cache (#1049) 2018-07-12 12:40:21 +02:00
Colin Gagnaire 4c3e1dce93
fix arista memory output (#1048) 2018-07-12 12:01:33 +02:00
cgagnaire 07d3bb5fa2
fix peplink silverpeak plugins typos (#1045)
* fix peplink plugin typos

* fix silverpeak plugin typos
2018-07-11 17:09:09 +02:00
tcharles 3e2f40aaaf starting peplink loadbalancer monitoring (#1015)
* Create memory.pm

* Create cpu.pm

* Create plugin.pm
2018-07-11 16:48:01 +02:00
pkriko c4a325ce03 add silverpeak plugin (#1037)
* added silverpeak plugin and modes

* fix type, oid  name and timealarms

* fix cache file name
2018-07-11 16:41:06 +02:00
cgagnaire 9f6aa3e3a2 fix hirschmann psu wrong oid (#985) 2018-05-14 16:04:36 +02:00
cgagnaire f0b126bfcc enhance sonicwall plugin (#978) 2018-05-02 17:45:28 +02:00
cgagnaire c543da8fc8 fix f5 bigip trunks div by 0 error (#977)
Closes https://github.com/centreon/centreon-plugins/issues/976
2018-05-02 17:25:23 +02:00
cgagnaire 20aa8571c9 add basic option to mode using http lib (#975) 2018-05-02 09:31:06 +02:00
cgagnaire 0fa87f7709 fix riverbed steelhead typo (#972)
* fix riverbed steelhead typo
2018-04-26 17:13:41 +02:00
cgagnaire baa8b8602c refactor riverbed steelhead (#971)
* Closes https://github.com/centreon/centreon-plugins/issues/970
2018-04-26 15:32:17 +02:00
cgagnaire c850241d4b fix f5 bigip trunks (#966) 2018-04-24 14:37:20 +02:00
cgagnaire 9a291d3695 add ssl opt harmonization (#965)
- Closes https://github.com/centreon/centreon-plugins/issues/961
- enhance el7 perl ssl compatibility
- add proxy option where missing
2018-04-23 13:54:07 +02:00
cgagnaire 15e8bcb085 fix f5 bigip failover warning thresholds (#964)
Closes https://github.com/centreon/centreon-plugins/issues/963
2018-04-23 12:04:19 +02:00
cgagnaire 321bed23b5 Enhance juniper ssg plugin (#959)
Closes https://github.com/centreon/centreon-plugins/issues/891

* enhance juniper ssg plugin
* fix key loop and hash init
2018-04-18 22:23:53 +02:00
Simon Bomm 8473f5fb50
Sonicwall plugin (#922)
* + add plugin for sonicwall

Ref https://github.com/centreon/centreon-plugins/issues/914
2018-04-16 22:18:02 +02:00
Simon Bomm ee37de83ab
Merge pull request #931 from cgagnaire/872-add-mode-f5-trunk
add modes trunks and list-trunks
2018-04-09 10:15:54 +02:00
cgagnaire 839e68fa79 fix stormshield hanodes mode 2018-03-30 14:56:49 +02:00
cgagnaire d1b8b6cba8 fix bad character f5 vs and pool 2018-03-27 23:15:41 +02:00
cgagnaire 7528cc2a84 add modes trunks and list-trunks 2018-03-27 22:01:09 +02:00
Simon Bomm f3fb8ccc52
Merge pull request #921 from jdidierpichat/master
update hardware.pm
2018-03-23 17:36:15 +01:00
jdidierpichat 1da5f891ab
update hardware.pm
[root@server~]# /usr/lib/nagios/plugins/centreon_plugins.pl --plugin=network::bluecoat::snmp::plugin --mode=hardware --hostname='x.x.x.x' --snmp-version='2c' --snmp-community='neuronesit_csc_ro' --snmp-timeout='30' --verbose
OK: All 71 components are ok [8/8 disks, 63/63 sensors]. | 'DIMM A1 temperature'=34C;;;; 'DIMM A2 temperature'=34C;;;; 'DIMM B1 temperature'=32C;;;; 'DIMM B2 temperature'=151C;;;; 'DIMM C1 temperature'=151C;;;; 'DIMM C2 temperature'=151C;;;; 'Front panel temperature'=23C;;;; 'Midplane center temperature'=27C;;;; 'Midplane left temperature'=26C;;;; 'Midplane right temperature'=26C;;;; 'PCH temperature'=46C;;;; 'Power supply 1 core temperature'=31C;;;; 'Power supply 2 core temperature'=29C;;;; 'Power supply inlet temperature'=26C;;;; 'SAS controller temperature'=39C;;;; 'SSL card temperature'=26C;;;; 'System center temperature'=39C;;;; 'System left temperature'=34C;;;; 'System right temperature'=35C;;;; 'CPU temperature'=42C;;;; 'Power supply 1 fan speed'=12000rpm;;;; 'Power supply 2 fan speed'=12100rpm;;;; 'Power supply 1 front fan speed'=15100rpm;;;; 'Power supply 1 rear fan speed'=15100rpm;;;; 'Power supply 2 front fan speed'=15100rpm;;;; 'Power supply 2 rear fan speed'=15100rpm;;;; 'System fan 1 front speed'=8100rpm;;;; 'System fan 1 rear speed'=6900rpm;;;; 'System fan 2 front speed'=8000rpm;;;; 'System fan 2 rear speed'=6800rpm;;;; 'System fan 3 front speed'=8100rpm;;;; 'System fan 3 rear speed'=6800rpm;;;; 'System fan 4 front speed'=8100rpm;;;; 'System fan 4 rear speed'=6800rpm;;;; 'System fan 5 front speed'=8100rpm;;;; 'System fan 5 rear speed'=6800rpm;;;; 'System fan 6 front speed'=8000rpm;;;; 'System fan 6 rear speed'=6900rpm;;;; '+1.1V standby voltage'=1.1172V;;;; '+12V main bus 1 voltage'=12.155V;;;; '+12V main bus 2 voltage'=12.09V;;;; '+3.3V main bus voltage'=3.292V;;;; '+3.3V standby voltage'=3.247V;;;; '+5V main bus voltage'=5.0232V;;;; '+5V standby voltage'=5.0508V;;;; '+3V battery voltage'=3.072V;;;; 'BMC memory voltage'=1.552V;;;; 'BMC PLL voltage'=1.264V;;;; 'CPU core voltage'=0.8134V;;;; 'CPU PLL voltage'=1.8326V;;;; 'CPU system agent voltage'=0.9016V;;;; 'CPU termination voltage'=1.064V;;;; 'Memory I/O voltage'=1.52V;;;; 'Memory termination voltage'=0.744V;;;; 'PCH core voltage'=1.12V;;;; 'PCH SAS voltage'=1.52V;;;; 'SAS core voltage'=1.048V;;;; 'SAS I/O voltage'=1.8326V;;;; 'SSL core voltage'=0.904V;;;; 'SSL PLL voltage'=1.8V;;;; 'SSL VPTX voltage'=1.8V;;;;
Checking sensors
Sensor 'DIMM A1 temperature' status is 'ok' [instance: 1, operational status: ok, value: 34, scale: 0, unit: C]
Sensor 'DIMM A2 temperature' status is 'ok' [instance: 2, operational status: ok, value: 34, scale: 0, unit: C]
Sensor 'DIMM B1 temperature' status is 'ok' [instance: 3, operational status: ok, value: 32, scale: 0, unit: C]
Sensor 'DIMM B2 temperature' status is 'notInstalled' [instance: 4, operational status: unknown, value: 151, scale: 0, unit: C]
Sensor 'DIMM C1 temperature' status is 'notInstalled' [instance: 5, operational status: unknown, value: 151, scale: 0, unit: C]
Sensor 'DIMM C2 temperature' status is 'notInstalled' [instance: 6, operational status: unknown, value: 151, scale: 0, unit: C]
Sensor 'Front panel temperature' status is 'ok' [instance: 7, operational status: ok, value: 23, scale: 0, unit: C]
Sensor 'Midplane center temperature' status is 'ok' [instance: 8, operational status: ok, value: 27, scale: 0, unit: C]
Sensor 'Midplane left temperature' status is 'ok' [instance: 9, operational status: ok, value: 26, scale: 0, unit: C]
Sensor 'Midplane right temperature' status is 'ok' [instance: 10, operational status: ok, value: 26, scale: 0, unit: C]
Sensor 'PCH temperature' status is 'ok' [instance: 11, operational status: ok, value: 46, scale: 0, unit: C]
Sensor 'Power supply 1 core temperature' status is 'ok' [instance: 12, operational status: ok, value: 31, scale: 0, unit: C]
Sensor 'Power supply 2 core temperature' status is 'ok' [instance: 13, operational status: ok, value: 29, scale: 0, unit: C]
Sensor 'Power supply inlet temperature' status is 'ok' [instance: 14, operational status: ok, value: 26, scale: 0, unit: C]
Sensor 'SAS controller temperature' status is 'ok' [instance: 15, operational status: ok, value: 39, scale: 0, unit: C]
Sensor 'SSL card temperature' status is 'notInstalled' [instance: 16, operational status: unknown, value: 26, scale: 0, unit: C]
Sensor 'System center temperature' status is 'ok' [instance: 17, operational status: ok, value: 39, scale: 0, unit: C]
Sensor 'System left temperature' status is 'ok' [instance: 18, operational status: ok, value: 34, scale: 0, unit: C]
Sensor 'System right temperature' status is 'ok' [instance: 19, operational status: ok, value: 35, scale: 0, unit: C]
Sensor 'CPU temperature' status is 'ok' [instance: 20, operational status: ok, value: 42, scale: 0, unit: C]
Sensor 'Power supply 1 fan speed' status is 'ok' [instance: 21, operational status: ok, value: 12000, scale: 0, unit: rpm]
Sensor 'Power supply 2 fan speed' status is 'ok' [instance: 22, operational status: ok, value: 12100, scale: 0, unit: rpm]
Sensor 'Power supply 1 front fan speed' status is 'notInstalled' [instance: 23, operational status: unknown, value: 15100, scale: 0, unit: rpm]
Sensor 'Power supply 1 rear fan speed' status is 'notInstalled' [instance: 24, operational status: unknown, value: 15100, scale: 0, unit: rpm]
Sensor 'Power supply 2 front fan speed' status is 'notInstalled' [instance: 25, operational status: unknown, value: 15100, scale: 0, unit: rpm]
Sensor 'Power supply 2 rear fan speed' status is 'notInstalled' [instance: 26, operational status: unknown, value: 15100, scale: 0, unit: rpm]
Sensor 'System fan 1 front speed' status is 'ok' [instance: 27, operational status: ok, value: 8100, scale: 0, unit: rpm]
Sensor 'System fan 1 rear speed' status is 'ok' [instance: 28, operational status: ok, value: 6900, scale: 0, unit: rpm]
Sensor 'System fan 2 front speed' status is 'ok' [instance: 29, operational status: ok, value: 8000, scale: 0, unit: rpm]
Sensor 'System fan 2 rear speed' status is 'ok' [instance: 30, operational status: ok, value: 6800, scale: 0, unit: rpm]
Sensor 'System fan 3 front speed' status is 'ok' [instance: 31, operational status: ok, value: 8100, scale: 0, unit: rpm]
Sensor 'System fan 3 rear speed' status is 'ok' [instance: 32, operational status: ok, value: 6800, scale: 0, unit: rpm]
Sensor 'System fan 4 front speed' status is 'ok' [instance: 33, operational status: ok, value: 8100, scale: 0, unit: rpm]
Sensor 'System fan 4 rear speed' status is 'ok' [instance: 34, operational status: ok, value: 6800, scale: 0, unit: rpm]
Sensor 'System fan 5 front speed' status is 'ok' [instance: 35, operational status: ok, value: 8100, scale: 0, unit: rpm]
Sensor 'System fan 5 rear speed' status is 'ok' [instance: 36, operational status: ok, value: 6800, scale: 0, unit: rpm]
Sensor 'System fan 6 front speed' status is 'ok' [instance: 37, operational status: ok, value: 8000, scale: 0, unit: rpm]
Sensor 'System fan 6 rear speed' status is 'ok' [instance: 38, operational status: ok, value: 6900, scale: 0, unit: rpm]
Sensor '+1.1V standby voltage' status is 'ok' [instance: 39, operational status: ok, value: 11172, scale: -4, unit: V]
Sensor '+12V main bus 1 voltage' status is 'ok' [instance: 40, operational status: ok, value: 12155, scale: -3, unit: V]
Sensor '+12V main bus 2 voltage' status is 'ok' [instance: 41, operational status: ok, value: 12090, scale: -3, unit: V]
Sensor '+3.3V main bus voltage' status is 'ok' [instance: 42, operational status: ok, value: 3292, scale: -3, unit: V]
Sensor '+3.3V standby voltage' status is 'ok' [instance: 43, operational status: ok, value: 3247, scale: -3, unit: V]
Sensor '+5V main bus voltage' status is 'ok' [instance: 44, operational status: ok, value: 50232, scale: -4, unit: V]
Sensor '+5V standby voltage' status is 'ok' [instance: 45, operational status: ok, value: 50508, scale: -4, unit: V]
Sensor '+3V battery voltage' status is 'ok' [instance: 46, operational status: ok, value: 3072, scale: -3, unit: V]
Sensor 'BMC memory voltage' status is 'ok' [instance: 47, operational status: ok, value: 1552, scale: -3, unit: V]
Sensor 'BMC PLL voltage' status is 'ok' [instance: 48, operational status: ok, value: 1264, scale: -3, unit: V]
Sensor 'CPU core voltage' status is 'ok' [instance: 49, operational status: ok, value: 8134, scale: -4, unit: V]
Sensor 'CPU PLL voltage' status is 'ok' [instance: 50, operational status: ok, value: 18326, scale: -4, unit: V]
Sensor 'CPU system agent voltage' status is 'ok' [instance: 51, operational status: ok, value: 9016, scale: -4, unit: V]
Sensor 'CPU termination voltage' status is 'ok' [instance: 52, operational status: ok, value: 1064, scale: -3, unit: V]
Sensor 'Memory I/O voltage' status is 'ok' [instance: 53, operational status: ok, value: 1520, scale: -3, unit: V]
Sensor 'Memory termination voltage' status is 'ok' [instance: 54, operational status: ok, value: 744, scale: -3, unit: V]
Sensor 'PCH core voltage' status is 'ok' [instance: 55, operational status: ok, value: 1120, scale: -3, unit: V]
Sensor 'PCH SAS voltage' status is 'ok' [instance: 56, operational status: ok, value: 1520, scale: -3, unit: V]
Sensor 'SAS core voltage' status is 'ok' [instance: 57, operational status: ok, value: 1048, scale: -3, unit: V]
Sensor 'SAS I/O voltage' status is 'ok' [instance: 58, operational status: ok, value: 18326, scale: -4, unit: V]
Sensor 'SSL core voltage' status is 'notInstalled' [instance: 59, operational status: unknown, value: 904, scale: -3, unit: V]
Sensor 'SSL PLL voltage' status is 'notInstalled' [instance: 60, operational status: unknown, value: 1800, scale: -3, unit: V]
Sensor 'SSL VPTX voltage' status is 'notInstalled' [instance: 61, operational status: unknown, value: 1800, scale: -3, unit: V]
Sensor 'Power supply 1 status' status is 'ok' [instance: 62, operational status: ok, value: 8, scale: 0, unit: ]
Sensor 'Power supply 2 status' status is 'ok' [instance: 63, operational status: ok, value: 8, scale: 0, unit: ]
Checking disks
Disk 'KZKN5AAH' status is 'present' [instance: 1]
Disk 'KZJK3XJG' status is 'present' [instance: 2]
Disk 'KZKJM81H' status is 'present' [instance: 3]
Disk 'KZKN9KPH' status is 'present' [instance: 4]
Disk 'KZKNVT2G' status is 'present' [instance: 5]
Disk 'KZKNNLZH' status is 'present' [instance: 6]
Disk '' status is 'notpresent' [instance: 7]
Disk '' status is 'notpresent' [instance: 8]
2018-03-23 11:42:26 +01:00
Fabien THEPAUT 33521303f1 New Year ! 2018-01-29 14:11:11 +01:00
qgarnier 747af00f96 Fix #847 2018-01-04 16:52:32 +01:00
qgarnier 81d2189d2e add cisco call manager plugin snmp 2017-12-22 14:07:08 +01:00
qgarnier c6ac9e90f2 add colubris snmp plugin 2017-12-12 16:55:38 +01:00
qgarnier 761de7e763 Fix #714 2017-12-08 14:09:17 +01:00
qgarnier d62ed5b3e4 Ref #714 : WIP infoblox 2017-12-08 11:53:22 +01:00
qgarnier 0ba639bcba add sessions mode for zyxel 2017-12-07 14:03:14 +01:00
qgarnier 04a4760ba8 add paloalto memory mode 2017-12-07 11:49:29 +01:00
qgarnier 4453285a10 add arista memory mode 2017-12-07 11:29:48 +01:00
qgarnier 0e2851ee43 Fix #815 2017-12-07 10:35:52 +01:00
qgarnier ae63c23983 enhance name for entity standard mode 2017-12-07 10:17:08 +01:00
qgarnier df7a77dd55
Merge pull request #817 from arnaud-michel/arista
Arista
2017-12-07 10:06:27 +01:00