*** Settings *** Documentation HPE Primera Storage REST API Resource ${CURDIR}${/}..${/}..${/}..${/}..${/}resources/import.resource Suite Setup Start Mockoon ${MOCKOON_JSON} Suite Teardown Stop Mockoon Test Timeout 120s *** Variables *** ${MOCKOON_JSON} ${CURDIR}${/}hpe-primera.mockoon.json ${HOSTNAME} 127.0.0.1 ${APIPORT} 3000 ${CMD} ${CENTREON_PLUGINS} ... --plugin=storage::hp::primera::restapi::plugin ... --mode disk-status ... --hostname=${HOSTNAME} ... --api-username=toto ... --api-password=toto ... --proto=http ... --port=${APIPORT} ... --custommode=api *** Test Cases *** Diskstatus ${tc} [Tags] storage api hpe hp ${output} Run ${CMD} ${extraoptions} ${output} Strip String ${output} Should Be Equal As Strings ... ${output} ... ${expected_result} ... Wrong output result for command:\n${CMD} ${extraoptions}\n\nObtained:\n${output}\n\nExpected:\n${expected_result}\n ... values=False ... collapse_spaces=True Examples: tc extraoptions expected_result -- ... 1 ${EMPTY} CRITICAL: Disk #73 (WDC/WLEB14T0S5xeF7.2, serial: 9MJ4SWLT) located 7:5:0 is failed WARNING: Disk #75 (WDC/WLEB14T0S5xeF7.2, serial: 9MJ4SSKT) located 8:1:0 is unknown - Disk #78 (WDC/WLEB14T0S5xeF7.2, serial: 9MJ4TLLT) located 8:4:0 is new - Disk #79 (WDC/WLEB14T0S5xeF7.2, serial: 9MJ4N1TT) located 8:5:0 is new - Disk #81 (WDC/WLEB14T0S5xeF7.2, serial: 9MJ4N8UT) located 8:7:0 is degraded | 'disks.total.count'=82;;;0; 'disks.normal.count'=77;;;0;82 'disks.degraded.count'=1;;;0;82 'disks.new.count'=2;;;0;82 'disks.failed.count'=1;;;0;82 'disks.unknown.count'=1;;;0;82 ... 2 --critical-status='' WARNING: Disk #75 (WDC/WLEB14T0S5xeF7.2, serial: 9MJ4SSKT) located 8:1:0 is unknown - Disk #78 (WDC/WLEB14T0S5xeF7.2, serial: 9MJ4TLLT) located 8:4:0 is new - Disk #79 (WDC/WLEB14T0S5xeF7.2, serial: 9MJ4N1TT) located 8:5:0 is new - Disk #81 (WDC/WLEB14T0S5xeF7.2, serial: 9MJ4N8UT) located 8:7:0 is degraded | 'disks.total.count'=82;;;0; 'disks.normal.count'=77;;;0;82 'disks.degraded.count'=1;;;0;82 'disks.new.count'=2;;;0;82 'disks.failed.count'=1;;;0;82 'disks.unknown.count'=1;;;0;82 ... 3 --warning-status='' CRITICAL: Disk #73 (WDC/WLEB14T0S5xeF7.2, serial: 9MJ4SWLT) located 7:5:0 is failed | 'disks.total.count'=82;;;0; 'disks.normal.count'=77;;;0;82 'disks.degraded.count'=1;;;0;82 'disks.new.count'=2;;;0;82 'disks.failed.count'=1;;;0;82 'disks.unknown.count'=1;;;0;82 ... 4 --warning-disks-new=0 CRITICAL: Disk #73 (WDC/WLEB14T0S5xeF7.2, serial: 9MJ4SWLT) located 7:5:0 is failed WARNING: Disks new: 2 - Disk #75 (WDC/WLEB14T0S5xeF7.2, serial: 9MJ4SSKT) located 8:1:0 is unknown - Disk #78 (WDC/WLEB14T0S5xeF7.2, serial: 9MJ4TLLT) located 8:4:0 is new - Disk #79 (WDC/WLEB14T0S5xeF7.2, serial: 9MJ4N1TT) located 8:5:0 is new - Disk #81 (WDC/WLEB14T0S5xeF7.2, serial: 9MJ4N8UT) located 8:7:0 is degraded | 'disks.total.count'=82;;;0; 'disks.normal.count'=77;;;0;82 'disks.degraded.count'=1;;;0;82 'disks.new.count'=2;0:0;;0;82 'disks.failed.count'=1;;;0;82 'disks.unknown.count'=1;;;0;82 ... 5 --warning-disks-total=83:83 CRITICAL: Disk #73 (WDC/WLEB14T0S5xeF7.2, serial: 9MJ4SWLT) located 7:5:0 is failed WARNING: Disks total: 82 - Disk #75 (WDC/WLEB14T0S5xeF7.2, serial: 9MJ4SSKT) located 8:1:0 is unknown - Disk #78 (WDC/WLEB14T0S5xeF7.2, serial: 9MJ4TLLT) located 8:4:0 is new - Disk #79 (WDC/WLEB14T0S5xeF7.2, serial: 9MJ4N1TT) located 8:5:0 is new - Disk #81 (WDC/WLEB14T0S5xeF7.2, serial: 9MJ4N8UT) located 8:7:0 is degraded | 'disks.total.count'=82;83:83;;0; 'disks.normal.count'=77;;;0;82 'disks.degraded.count'=1;;;0;82 'disks.new.count'=2;;;0;82 'disks.failed.count'=1;;;0;82 'disks.unknown.count'=1;;;0;82 ... 6 --critical-disks-failed=0 CRITICAL: Disks failed: 1 - Disk #73 (WDC/WLEB14T0S5xeF7.2, serial: 9MJ4SWLT) located 7:5:0 is failed WARNING: Disk #75 (WDC/WLEB14T0S5xeF7.2, serial: 9MJ4SSKT) located 8:1:0 is unknown - Disk #78 (WDC/WLEB14T0S5xeF7.2, serial: 9MJ4TLLT) located 8:4:0 is new - Disk #79 (WDC/WLEB14T0S5xeF7.2, serial: 9MJ4N1TT) located 8:5:0 is new - Disk #81 (WDC/WLEB14T0S5xeF7.2, serial: 9MJ4N8UT) located 8:7:0 is degraded | 'disks.total.count'=82;;;0; 'disks.normal.count'=77;;;0;82 'disks.degraded.count'=1;;;0;82 'disks.new.count'=2;;;0;82 'disks.failed.count'=1;;0:0;0;82 'disks.unknown.count'=1;;;0;82 ... 7 --warning-disks-degraded=0 CRITICAL: Disk #73 (WDC/WLEB14T0S5xeF7.2, serial: 9MJ4SWLT) located 7:5:0 is failed WARNING: Disks degraded: 1 - Disk #75 (WDC/WLEB14T0S5xeF7.2, serial: 9MJ4SSKT) located 8:1:0 is unknown - Disk #78 (WDC/WLEB14T0S5xeF7.2, serial: 9MJ4TLLT) located 8:4:0 is new - Disk #79 (WDC/WLEB14T0S5xeF7.2, serial: 9MJ4N1TT) located 8:5:0 is new - Disk #81 (WDC/WLEB14T0S5xeF7.2, serial: 9MJ4N8UT) located 8:7:0 is degraded | 'disks.total.count'=82;;;0; 'disks.normal.count'=77;;;0;82 'disks.degraded.count'=1;0:0;;0;82 'disks.new.count'=2;;;0;82 'disks.failed.count'=1;;;0;82 'disks.unknown.count'=1;;;0;82 ... 8 --warning-disks-unknown=0 CRITICAL: Disk #73 (WDC/WLEB14T0S5xeF7.2, serial: 9MJ4SWLT) located 7:5:0 is failed WARNING: Disks unknown: 1 - Disk #75 (WDC/WLEB14T0S5xeF7.2, serial: 9MJ4SSKT) located 8:1:0 is unknown - Disk #78 (WDC/WLEB14T0S5xeF7.2, serial: 9MJ4TLLT) located 8:4:0 is new - Disk #79 (WDC/WLEB14T0S5xeF7.2, serial: 9MJ4N1TT) located 8:5:0 is new - Disk #81 (WDC/WLEB14T0S5xeF7.2, serial: 9MJ4N8UT) located 8:7:0 is degraded | 'disks.total.count'=82;;;0; 'disks.normal.count'=77;;;0;82 'disks.degraded.count'=1;;;0;82 'disks.new.count'=2;;;0;82 'disks.failed.count'=1;;;0;82 'disks.unknown.count'=1;0:0;;0;82 ... 9 --warning-disks-normal=82:82 CRITICAL: Disk #73 (WDC/WLEB14T0S5xeF7.2, serial: 9MJ4SWLT) located 7:5:0 is failed WARNING: Disks normal: 77 - Disk #75 (WDC/WLEB14T0S5xeF7.2, serial: 9MJ4SSKT) located 8:1:0 is unknown - Disk #78 (WDC/WLEB14T0S5xeF7.2, serial: 9MJ4TLLT) located 8:4:0 is new - Disk #79 (WDC/WLEB14T0S5xeF7.2, serial: 9MJ4N1TT) located 8:5:0 is new - Disk #81 (WDC/WLEB14T0S5xeF7.2, serial: 9MJ4N8UT) located 8:7:0 is degraded | 'disks.total.count'=82;;;0; 'disks.normal.count'=77;82:82;;0;82 'disks.degraded.count'=1;;;0;82 'disks.new.count'=2;;;0;82 'disks.failed.count'=1;;;0;82 'disks.unknown.count'=1;;;0;82