# # Copyright 2020 Centreon (http://www.centreon.com/) # # Centreon is a full-fledged industry-strength solution that meets # the needs in IT infrastructure and application monitoring for # service performance. # # Licensed under the Apache License, Version 2.0 (the "License"); # you may not use this file except in compliance with the License. # You may obtain a copy of the License at # # http://www.apache.org/licenses/LICENSE-2.0 # # Unless required by applicable law or agreed to in writing, software # distributed under the License is distributed on an "AS IS" BASIS, # WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. # See the License for the specific language governing permissions and # limitations under the License. # package hardware::ups::apc::snmp::mode::batterystatus; use base qw(centreon::plugins::templates::counter); use strict; use warnings; use DateTime; use centreon::plugins::templates::catalog_functions; sub custom_status_output { my ($self, %options) = @_; return sprintf( "battery status is '%s' [battery needs replace: %s] [last replace date: %s]", $self->{result_values}->{status}, $self->{result_values}->{replace}, $self->{result_values}->{last_replace_date} ); } sub custom_status_calc { my ($self, %options) = @_; $self->{result_values}->{status} = $options{new_datas}->{$self->{instance} . '_upsBasicBatteryStatus'}; $self->{result_values}->{replace} = $options{new_datas}->{$self->{instance} . '_upsAdvBatteryReplaceIndicator'}; $self->{result_values}->{last_replace_date} = $options{new_datas}->{$self->{instance} . '_upsBasicBatteryLastReplaceDate'}; return 0; } sub set_counters { my ($self, %options) = @_; $self->{maps_counters_type} = [ { name => 'global', type => 0, skipped_code => { -10 => 1 } }, ]; $self->{maps_counters}->{global} = [ { label => 'status', threshold => 0, set => { key_values => [ { name => 'upsBasicBatteryStatus' }, { name => 'upsAdvBatteryReplaceIndicator' }, { name => 'upsBasicBatteryLastReplaceDate' } ], closure_custom_calc => $self->can('custom_status_calc'), closure_custom_output => $self->can('custom_status_output'), closure_custom_perfdata => sub { return 0; }, closure_custom_threshold_check => \¢reon::plugins::templates::catalog_functions::catalog_status_threshold, } }, { label => 'load', nlabel => 'battery.charge.remaining.percent', set => { key_values => [ { name => 'upsAdvBatteryCapacity' } ], output_template => 'remaining capacity: %s %%', perfdatas => [ { label => 'load', value => 'upsAdvBatteryCapacity_absolute', template => '%s', min => 0, max => 100, unit => '%' }, ], } }, { label => 'time', nlabel => 'battery.charge.remaining.minutes', set => { key_values => [ { name => 'upsAdvBatteryRunTimeRemaining' } ], output_template => 'remaining time: %.2f minutes', perfdatas => [ { label => 'load_time', value => 'upsAdvBatteryRunTimeRemaining_absolute', template => '%.2f', min => 0, unit => 'm' }, ], } }, { label => 'current', nlabel => 'battery.current.ampere', set => { key_values => [ { name => 'upsAdvBatteryCurrent' } ], output_template => 'current: %s A', perfdatas => [ { label => 'current', value => 'upsAdvBatteryCurrent_absolute', template => '%s', min => 0, unit => 'A' }, ], } }, { label => 'voltage', nlabel => 'battery.voltage.volt', set => { key_values => [ { name => 'upsAdvBatteryActualVoltage' } ], output_template => 'voltage: %s V', perfdatas => [ { label => 'voltage', value => 'upsAdvBatteryActualVoltage_absolute', template => '%s', unit => 'V' }, ], } }, { label => 'temperature', nlabel => 'battery.temperature.celsius', set => { key_values => [ { name => 'upsAdvBatteryTemperature' } ], output_template => 'temperature: %s C', perfdatas => [ { label => 'temperature', value => 'upsAdvBatteryTemperature_absolute', template => '%s', unit => 'C'}, ], } }, { label => 'replace-lasttime', nlabel => 'battery.replace.lasttime.seconds', display_ok => 0, set => { key_values => [ { name => 'last_replace_time' } ], output_template => 'replace last time: %s s', perfdatas => [ { label => 'replace_last_time', value => 'last_replace_time_absolute', template => '%s', unit => 's'}, ], } } ]; } sub new { my ($class, %options) = @_; my $self = $class->SUPER::new(package => __PACKAGE__, %options); bless $self, $class; $options{options}->add_options(arguments => { 'unknown-status:s' => { name => 'unknown_status', default => '%{status} =~ /unknown/i' }, 'warning-status:s' => { name => 'warning_status', default => '%{status} =~ /batteryLow/i' }, 'critical-status:s' => { name => 'critical_status', default => '%{replace} =~ /yes/i' }, }); return $self; } sub check_options { my ($self, %options) = @_; $self->SUPER::check_options(%options); $self->change_macros(macros => ['unknown_status', 'warning_status', 'critical_status']); } my $map_battery_status = { 1 => 'unknown', 2 => 'batteryNormal', 3 => 'batteryLow' }; my $map_replace_status = { 1 => 'no', 2 => 'yes' }; my $mapping = { upsBasicBatteryStatus => { oid => '.1.3.6.1.4.1.318.1.1.1.2.1.1', map => $map_battery_status }, upsBasicBatteryTimeOnBattery => { oid => '.1.3.6.1.4.1.318.1.1.1.2.1.2' }, upsBasicBatteryLastReplaceDate => { oid => '.1.3.6.1.4.1.318.1.1.1.2.1.3' }, }; my $mapping2 = { upsAdvBatteryCapacity => { oid => '.1.3.6.1.4.1.318.1.1.1.2.2.1' }, upsAdvBatteryTemperature => { oid => '.1.3.6.1.4.1.318.1.1.1.2.2.2' }, upsAdvBatteryRunTimeRemaining => { oid => '.1.3.6.1.4.1.318.1.1.1.2.2.3' }, upsAdvBatteryReplaceIndicator => { oid => '.1.3.6.1.4.1.318.1.1.1.2.2.4', map => $map_replace_status }, upsAdvBatteryActualVoltage => { oid => '.1.3.6.1.4.1.318.1.1.1.2.2.8' }, upsAdvBatteryCurrent => { oid => '.1.3.6.1.4.1.318.1.1.1.2.2.9' }, }; my $oid_upsBasicBattery = '.1.3.6.1.4.1.318.1.1.1.2.1'; my $oid_upsAdvBattery = '.1.3.6.1.4.1.318.1.1.1.2.2'; sub manage_selection { my ($self, %options) = @_; my $snmp_result = $options{snmp}->get_multiple_table( oids => [ { oid => $oid_upsBasicBattery }, { oid => $oid_upsAdvBattery }, ], nothing_quit => 1 ); $self->{global} = {}; my $result = $options{snmp}->map_instance(mapping => $mapping, results => $snmp_result->{$oid_upsBasicBattery}, instance => '0'); my $result2 = $options{snmp}->map_instance(mapping => $mapping2, results => $snmp_result->{$oid_upsAdvBattery}, instance => '0'); $result2->{upsAdvBatteryRunTimeRemaining} = sprintf("%.0f", $result2->{upsAdvBatteryRunTimeRemaining} / 100 / 60) if (defined($result2->{upsAdvBatteryRunTimeRemaining})); $self->{global} = { %$result, %$result2 }; if (defined($result->{upsBasicBatteryLastReplaceDate}) && $result->{upsBasicBatteryLastReplaceDate} =~ /(\d{2})\/(\d{2})\/(\d{4})/) { my $dt = DateTime->new(year => $3, month => $1, day => $2, hour => 0, minute => 0, second => 0); $self->{global}->{last_replace_time} = time() - $dt->epoch; } } 1; __END__ =head1 MODE Check battery status and battery charge remaining. =over 8 =item B<--filter-counters> Only display some counters (regexp can be used). Example: --filter-counters='^status|load$' =item B<--unknown-status> Set unknown threshold for status (Default: '%{status} =~ /unknown/i'). Can used special variables like: %{status}, %{replace} =item B<--warning-status> Set warning threshold for status (Default: '%{status} =~ /batteryLow/i'). Can used special variables like: %{status}, %{replace} =item B<--critical-status> Set critical threshold for status (Default: '%{replace} =~ /yes/i'). Can used special variables like: %{status}, %{replace} =item B<--warning-*> B<--critical-*> Thresholds. Can be: 'load', 'voltage', 'current', 'temperature', 'time', 'replace-lasttime'. =back =cut