centreon-plugins/hardware/server/hp/proliant/snmp/mode/components/psu.pm

140 lines
6.4 KiB
Perl

################################################################################
# Copyright 2005-2013 MERETHIS
# Centreon is developped by : Julien Mathis and Romain Le Merlus under
# GPL Licence 2.0.
#
# This program is free software; you can redistribute it and/or modify it under
# the terms of the GNU General Public License as published by the Free Software
# Foundation ; either version 2 of the License.
#
# This program is distributed in the hope that it will be useful, but WITHOUT ANY
# WARRANTY; without even the implied warranty of MERCHANTABILITY or FITNESS FOR A
# PARTICULAR PURPOSE. See the GNU General Public License for more details.
#
# You should have received a copy of the GNU General Public License along with
# this program; if not, see <http://www.gnu.org/licenses>.
#
# Linking this program statically or dynamically with other modules is making a
# combined work based on this program. Thus, the terms and conditions of the GNU
# General Public License cover the whole combination.
#
# As a special exception, the copyright holders of this program give MERETHIS
# permission to link this program with independent modules to produce an executable,
# regardless of the license terms of these independent modules, and to copy and
# distribute the resulting executable under terms of MERETHIS choice, provided that
# MERETHIS also meet, for each linked independent module, the terms and conditions
# of the license of that module. An independent module is a module which is not
# derived from this program. If you modify this program, you may extend this
# exception to your version of the program, but you are not obliged to do so. If you
# do not wish to do so, delete this exception statement from your version.
#
# For more information : contact@centreon.com
# Authors : Quentin Garnier <qgarnier@merethis.com>
#
####################################################################################
package hardware::server::hp::proliant::snmp::mode::components::psu;
use strict;
use warnings;
my %map_psu_condition = (
1 => 'other',
2 => 'ok',
3 => 'degraded',
4 => 'failed',
);
my %map_present = (
1 => 'other',
2 => 'absent',
3 => 'present',
);
my %map_redundant = (
1 => 'other',
2 => 'not redundant',
3 => 'redundant',
);
my %map_psu_status = (
1 => 'noError',
2 => 'generalFailure',
3 => 'bistFailure',
4 => 'fanFailure',
5 => 'tempFailure',
6 => 'interlockOpen',
7 => 'epromFailed',
8 => 'vrefFailed',
9 => 'dacFailed',
10 => 'ramTestFailed',
11 => 'voltageChannelFailed',
12 => 'orringdiodeFailed',
13 => 'brownOut',
14 => 'giveupOnStartup',
15 => 'nvramInvalid',
16 => 'calibrationTableInvalid',
);
# In MIB 'CPQHLTH-MIB.mib'
my $mapping = {
cpqHeFltTolPowerSupplyPresent => { oid => '.1.3.6.1.4.1.232.6.2.9.3.1.3', map => \%map_present },
cpqHeFltTolPowerSupplyCondition => { oid => '.1.3.6.1.4.1.232.6.2.9.3.1.4', map => \%map_psu_condition },
cpqHeFltTolPowerSupplyStatus => { oid => '.1.3.6.1.4.1.232.6.2.9.3.1.5', map => \%map_psu_status },
cpqHeFltTolPowerSupplyMainVoltage => { oid => '.1.3.6.1.4.1.232.6.2.9.3.1.6' },
cpqHeFltTolPowerSupplyCapacityUsed => { oid => '.1.3.6.1.4.1.232.6.2.9.3.1.7' },
cpqHeFltTolPowerSupplyCapacityMaximum => { oid => '.1.3.6.1.4.1.232.6.2.9.3.1.8' },
cpqHeFltTolPowerSupplyRedundant => { oid => '.1.3.6.1.4.1.232.6.2.9.3.1.9' },
};
my $mapping2 = {
cpqHeFltTolPowerSupplyRedundantPartner => { oid => '.1.3.6.1.4.1.232.6.2.9.3.1.17' },
};
my $oid_cpqHeFltTolPowerSupplyEntry = '.1.3.6.1.4.1.232.6.2.9.3.1';
my $oid_cpqHeFltTolPowerSupplyRedundantPartner = '.1.3.6.1.4.1.232.6.2.9.3.1.17';
sub load {
my (%options) = @_;
push @{$options{request}}, { oid => $oid_cpqHeFltTolPowerSupplyEntry, start => $mapping->{cpqHeFltTolPowerSupplyPresent}->{oid}, end => $mapping->{cpqHeFltTolPowerSupplyRedundant}->{oid} };
push @{$options{request}}, { oid => $oid_cpqHeFltTolPowerSupplyRedundantPartner };
}
sub check {
my ($self) = @_;
$self->{output}->output_add(long_msg => "Checking power supplies");
$self->{components}->{psu} = {name => 'power supplies', total => 0, skip => 0};
return if ($self->check_exclude(section => 'psu'));
foreach my $oid ($self->{snmp}->oid_lex_sort(keys %{$self->{results}->{$oid_cpqHeFltTolPowerSupplyEntry}})) {
next if ($oid !~ /^$mapping->{cpqHeFltTolPowerSupplyPresent}->{oid}\.(.*)$/);
my $instance = $1;
my $result = $self->{snmp}->map_instance(mapping => $mapping, results => $self->{results}->{$oid_cpqHeFltTolPowerSupplyEntry}, instance => $instance);
my $result2 = $self->{snmp}->map_instance(mapping => $mapping2, results => $self->{results}->{$oid_cpqHeFltTolPowerSupplyRedundantPartner}, instance => $instance);
next if ($self->check_exclude(section => 'psu', instance => $instance));
next if ($result->{cpqHeFltTolPowerSupplyPresent} !~ /present/i &&
$self->absent_problem(section => 'psu', instance => $instance));
$self->{components}->{psu}->{total}++;
$self->{output}->output_add(long_msg => sprintf("powersupply '%s' status is %s [redundance: %s, redundant partner: %s] (status %s).",
$instance, $result->{cpqHeFltTolPowerSupplyCondition},
$result->{cpqHeFltTolPowerSupplyRedundant}, $result2->{cpqHeFltTolPowerSupplyRedundantPartner},
$result->{cpqHeFltTolPowerSupplyStatus}
));
my $exit = $self->get_severity(section => 'psu', value => $result->{cpqHeFltTolPowerSupplyCondition});
if (!$self->{output}->is_status(value => $exit, compare => 'ok', litteral => 1)) {
$self->{output}->output_add(severity => $exit,
short_msg => sprintf("powersupply '%s' status is %s",
$instance, $result->{cpqHeFltTolPowerSupplyCondition}));
}
$self->{output}->perfdata_add(label => "psu_power_" . $instance, unit => 'W',
value => $result->{cpqHeFltTolPowerSupplyCapacityUsed},
critical => $result->{cpqHeFltTolPowerSupplyCapacityMaximum});
$self->{output}->perfdata_add(label => "psu__voltage" . $instance, unit => 'V',
value => $result->{cpqHeFltTolPowerSupplyMainVoltage});
}
}
1;