# Copyright 2015 Centreon (http://www.centreon.com/)
|
|
#
|
|
# Centreon is a full-fledged industry-strength solution that meets
|
|
# the needs in IT infrastructure and application monitoring for
|
|
# service performance.
|
|
#
|
|
# Licensed under the Apache License, Version 2.0 (the "License");
|
|
# you may not use this file except in compliance with the License.
|
|
# You may obtain a copy of the License at
|
|
#
|
|
# http://www.apache.org/licenses/LICENSE-2.0
|
|
#
|
|
# Unless required by applicable law or agreed to in writing, software
|
|
# distributed under the License is distributed on an "AS IS" BASIS,
|
|
# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
|
|
# See the License for the specific language governing permissions and
|
|
# limitations under the License.
|
|
#
|
|
|
|
#
|
|
# see http://manned.org/apcaccess
|
|
#
|
|
#sprung:~# apcaccess #
|
|
#APC : 001,048,1163 # version, number of records and number of bytes following
|
|
#DATE : 2014-03-15 19:30:58 +0100 # Date and time of last update from UPS
|
|
#HOSTNAME : sprung # hostname of computer running apcupsd
|
|
#VERSION : 3.14.8 (16 January 2010) debian # apcupsd version number, date and operating system
|
|
#UPSNAME : APC_ESX_SERVER # UPS name from configuration file (dumb) or EEPROM (smart)
|
|
#CABLE : Custom Cable Smart # Cable type specified in the configuration file
|
|
#MODEL : Smart-UPS 620 # UPS model derived from UPS information
|
|
#UPSMODE : ShareUPS Master # Mode in which UPS is operating
|
|
#STARTTIME: 2014-03-13 22:40:39 +0100 # Date and time apcupsd was started
|
|
#STATUS : ONLINE # UPS status (online, charging, on battery etc)
|
|
#LINEV : 224.6 Volts # Current input line voltage
|
|
#LOADPCT : 58.5 Percent Load Capacity # Percentage of UPS load capacity used as estimated by UPS
|
|
#BCHARGE : 100.0 Percent # Current battery capacity charge percentage
|
|
#TIMELEFT : 11.0 Minutes # Remaining runtime left on battery as estimated by UPS
|
|
#MBATTCHG : 10 Percent # Min battery charge % (BCHARGE) required for system shutdown
|
|
#MINTIMEL : 4 Minutes # Min battery runtime (MINUTES) required for system shutdown
|
|
#MAXTIME : 0 Seconds # Max battery runtime (TIMEOUT) after which system is shutdown
|
|
#MAXLINEV : 227.5 Volts # Maximum input line voltage since apcupsd startup
|
|
#MINLINEV : 224.6 Volts # Minimum input line voltage since apcupsd startup
|
|
#OUTPUTV : 227.5 Volts # UPS output voltage
|
|
#SENSE : High # Current UPS sensitivity setting for voltage fluctuations
|
|
#DWAKE : 060 Seconds # Time UPS waits after power off when the power is restored
|
|
#DSHUTD : 600 Seconds # Delay before UPS powers down after command received
|
|
#DLOWBATT : 02 Minutes # Low battery signal sent when this much runtime remains
|
|
#LOTRANS : 208.0 Volts # Input line voltage below which UPS will switch to battery
|
|
#HITRANS : 253.0 Volts # Input line voltage above which UPS will switch to battery
|
|
#RETPCT : 015.0 Percent # Battery charge % required after power off to restore power
|
|
#ALARMDEL : 30 seconds # Delay period before UPS starts sounding alarm
|
|
#BATTV : 13.8 Volts # Current battery voltage
|
|
#LINEFREQ : 50.0 Hz # Current line frequency in Hertz
|
|
#LASTXFER : No transfers since turnon # Reason for last transfer to battery since apcupsd startup
|
|
#NUMXFERS : 0 # Number of transfers to battery since apcupsd startup
|
|
#TONBATT : 0 seconds # Seconds currently on battery
|
|
#CUMONBATT: 0 seconds # Cumulative seconds on battery since apcupsd startup
|
|
#XOFFBATT : N/A # Date, time of last transfer off battery since apcupsd startup
|
|
#SELFTEST : NO # Date and time of last self test since apcupsd startup
|
|
#STESTI : OFF # Self-test interval
|
|
#STATFLAG : 0x07000008 Status Flag # UPS status flag in hex
|
|
#REG1 : 0x00 Register 1 # Fault register 1 in hex
|
|
#REG2 : 0x00 Register 2 # Fault register 2 in hex
|
|
#REG3 : 0x00 Register 3 # Fault register 3 in hex
|
|
#MANDATE : 08/09/01 # UPS date of manufacture
|
|
#SERIALNO : NS0132263041 # UPS serial number
|
|
#BATTDATE : 11/01/08 # Date battery last replaced (if set)
|
|
#NOMOUTV : 230 Volts # Nominal output voltage to supply when on battery power
|
|
#NOMBATTV : 12.0 Volts # Nominal battery voltage
|
|
#FIRMWARE : 22.6.I # UPS firmware version
|
|
#APCMODEL : CWI # APC model information
|
|
#END APC : 2014-03-15 19:31:00 +0100 # Date and time of status information was written
|
|
|
|
package apps::apcupsd::local::plugin;
|
|
|
|
use strict;
|
|
use warnings;
|
|
use base qw(centreon::plugins::script_simple);
|
|
|
|
sub new {
|
|
my ($class, %options) = @_;
|
|
my $self = $class->SUPER::new(package => __PACKAGE__, %options);
|
|
bless $self, $class;
|
|
# $options->{options} = options object
|
|
|
|
$self->{version} = '0.1';
|
|
%{$self->{modes}} = (
|
|
'batterycharge' => 'apps::apcupsd::local::mode::batterycharge', # BCHARGE
|
|
'temperature' => 'apps::apcupsd::local::mode::temperature', # ITEMP
|
|
'timeleft' => 'apps::apcupsd::local::mode::timeleft', # TIMELEFT MAXTIME MINTIMEL
|
|
'linevoltage' => 'apps::apcupsd::local::mode::linevoltage', # LINEV
|
|
'batteryvoltage' => 'apps::apcupsd::local::mode::batteryvoltage', # BATTV
|
|
'outputvoltage' => 'apps::apcupsd::local::mode::outputvoltage', # OUTPUTV
|
|
'linefrequency' => 'apps::apcupsd::local::mode::linefrequency', # LINEFREQ
|
|
'loadpercentage' => 'apps::apcupsd::local::mode::loadpercentage', # LOADPCT
|
|
);
|
|
return $self;
|
|
}
|
|
|
|
1;
|
|
|
|
__END__
|
|
|
|
=head1 PLUGIN DESCRIPTION
|
|
|
|
Check apcupsd through local commands (the plugin can use SSH).
|
|
|
|
=cut
|