# Copyright 2017 Centreon (http://www.centreon.com/)
#
# Centreon is a full-fledged industry-strength solution that meets
# the needs in IT infrastructure and application monitoring for
# service performance.
#
# Licensed under the Apache License, Version 2.0 (the "License");
# you may not use this file except in compliance with the License.
# You may obtain a copy of the License at
#
# http://www.apache.org/licenses/LICENSE-2.0
#
# Unless required by applicable law or agreed to in writing, software
# distributed under the License is distributed on an "AS IS" BASIS,
# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
# See the License for the specific language governing permissions and
# limitations under the License.
#
package hardware::server::hp::ilo::xmlapi::mode::components::memory;
use strict;
use warnings;
sub load { }
sub check {
my ($self) = @_;
$self->{output}->output_add(long_msg => "Checking memories");
$self->{components}->{memory} = {name => 'memory', total => 0, skip => 0};
return if ($self->check_filter(section => 'memory'));
return if (!defined($self->{xml_result}->{GET_EMBEDDED_HEALTH_DATA}->{MEMORY}->{MEMORY_DETAILS}));
#<MEMORY>
# <MEMORY_DETAILS>
# <CPU_1>
# <SOCKET VALUE = "1"/>
# <STATUS VALUE = "Good, In Use"/>
# <HP_SMART_MEMORY VALUE = "Yes"/>
# <PART NUMBER = "712383-081"/>
# <TYPE VALUE = "DIMM DDR3"/>
# <SIZE VALUE = "16384 MB"/>
# <FREQUENCY VALUE = "1866 MHz"/>
# <MINIMUM_VOLTAGE VALUE = "1.50 v"/>
# <RANKS VALUE = "2"/>
# <TECHNOLOGY VALUE = "RDIMM"/>
# </CPU_1>
foreach my $cpu_name (sort keys %{$self->{xml_result}->{GET_EMBEDDED_HEALTH_DATA}->{MEMORY}->{MEMORY_DETAILS}}) {
$self->{xml_result}->{GET_EMBEDDED_HEALTH_DATA}->{MEMORY}->{MEMORY_DETAILS}->{$cpu_name} = [$self->{xml_result}->{GET_EMBEDDED_HEALTH_DATA}->{MEMORY}->{MEMORY_DETAILS}->{$cpu_name}]
if (ref($self->{xml_result}->{GET_EMBEDDED_HEALTH_DATA}->{MEMORY}->{MEMORY_DETAILS}->{$cpu_name}) ne 'ARRAY');
foreach my $result (@{$self->{xml_result}->{GET_EMBEDDED_HEALTH_DATA}->{MEMORY}->{MEMORY_DETAILS}->{$cpu_name}}) {
my $instance = lc($cpu_name) . '.' . $result->{SOCKET}->{VALUE};
next if ($self->check_filter(section => 'memory', instance => $instance));
next if ($result->{STATUS}->{VALUE} =~ /not installed|n\/a|not present|not applicable/i &&
$self->absent_problem(section => 'memory', instance => $instance));
$self->{components}->{memory}->{total}++;
$self->{output}->output_add(long_msg => sprintf("memory '%s' status is '%s' [instance = %s]",
$instance, $result->{STATUS}->{VALUE}, $instance));
my $exit = $self->get_severity(label => 'default', section => 'memory', value => $result->{STATUS}->{VALUE});
if (!$self->{output}->is_status(value => $exit, compare => 'ok', litteral => 1)) {
$self->{output}->output_add(severity => $exit,
short_msg => sprintf("Memory '%s' status is '%s'", $instance, $result->{STATUS}->{VALUE}));
}
}
}
}
1;