109 lines
4.7 KiB
Perl
109 lines
4.7 KiB
Perl
################################################################################
|
|
# Copyright 2005-2013 MERETHIS
|
|
# Centreon is developped by : Julien Mathis and Romain Le Merlus under
|
|
# GPL Licence 2.0.
|
|
#
|
|
# This program is free software; you can redistribute it and/or modify it under
|
|
# the terms of the GNU General Public License as published by the Free Software
|
|
# Foundation ; either version 2 of the License.
|
|
#
|
|
# This program is distributed in the hope that it will be useful, but WITHOUT ANY
|
|
# WARRANTY; without even the implied warranty of MERCHANTABILITY or FITNESS FOR A
|
|
# PARTICULAR PURPOSE. See the GNU General Public License for more details.
|
|
#
|
|
# You should have received a copy of the GNU General Public License along with
|
|
# this program; if not, see <http://www.gnu.org/licenses>.
|
|
#
|
|
# Linking this program statically or dynamically with other modules is making a
|
|
# combined work based on this program. Thus, the terms and conditions of the GNU
|
|
# General Public License cover the whole combination.
|
|
#
|
|
# As a special exception, the copyright holders of this program give MERETHIS
|
|
# permission to link this program with independent modules to produce an executable,
|
|
# regardless of the license terms of these independent modules, and to copy and
|
|
# distribute the resulting executable under terms of MERETHIS choice, provided that
|
|
# MERETHIS also meet, for each linked independent module, the terms and conditions
|
|
# of the license of that module. An independent module is a module which is not
|
|
# derived from this program. If you modify this program, you may extend this
|
|
# exception to your version of the program, but you are not obliged to do so. If you
|
|
# do not wish to do so, delete this exception statement from your version.
|
|
#
|
|
# For more information : contact@centreon.com
|
|
# Authors : Quentin Garnier <qgarnier@merethis.com>
|
|
#
|
|
####################################################################################
|
|
|
|
package hardware::server::hpproliant::mode::components::pc;
|
|
|
|
use strict;
|
|
use warnings;
|
|
|
|
my %conditions = (
|
|
1 => ['other', 'CRITICAL'],
|
|
2 => ['ok', 'OK'],
|
|
3 => ['degraded', 'WARNING'],
|
|
4 => ['failed', 'CRITICAL']
|
|
);
|
|
|
|
my %present_map = (
|
|
1 => 'other',
|
|
2 => 'absent',
|
|
3 => 'present',
|
|
);
|
|
|
|
my %redundant_map = (
|
|
1 => 'other',
|
|
2 => 'not redundant',
|
|
3 => 'redundant',
|
|
);
|
|
|
|
sub check {
|
|
my ($self) = @_;
|
|
|
|
# In MIB 'CPQHLTH-MIB.mib'
|
|
$self->{output}->output_add(long_msg => "Checking power converters");
|
|
$self->{components}->{pc} = {name => 'power converters', total => 0};
|
|
return if ($self->check_exclude('pc'));
|
|
|
|
my $oid_cpqHePwrConvPresent = '.1.3.6.1.4.1.232.6.2.13.3.1.3';
|
|
my $oid_cpqHePwrConvIndex = '.1.3.6.1.4.1.232.6.2.13.3.1.2';
|
|
my $oid_cpqHePwrConvChassis = '.1.3.6.1.4.1.232.6.2.13.3.1.1';
|
|
my $oid_cpqHePwrConvCondition = '.1.3.6.1.4.1.232.6.2.13.3.1.8';
|
|
my $oid_cpqHePwrConvRedundant = '.1.3.6.1.4.1.232.6.2.13.3.1.6';
|
|
my $oid_cpqHePwrConvRedundantGroupId = '.1.3.6.1.4.1.232.6.2.13.3.1.7';
|
|
|
|
my $result = $self->{snmp}->get_table(oid => $oid_cpqHePwrConvPresent);
|
|
return if (scalar(keys %$result) <= 0);
|
|
my @get_oids = ();
|
|
my @oids_end = ();
|
|
foreach my $key ($self->{snmp}->oid_lex_sort(keys %$result)) {
|
|
next if ($present_map{$result->{$key}} ne 'present');
|
|
# Chassis + index
|
|
$key =~ /(\d+\.\d+)$/;
|
|
my $oid_end = $1;
|
|
|
|
push @oids_end, $oid_end;
|
|
push @get_oids, $oid_cpqHePwrConvCondition . "." . $oid_end, $oid_cpqHePwrConvRedundant . "." . $oid_end,
|
|
$oid_cpqHePwrConvRedundantGroupId . "." . $oid_end;
|
|
}
|
|
$result = $self->{snmp}->get_leef(oids => \@get_oids);
|
|
foreach (@oids_end) {
|
|
my ($pc_chassis, $pc_index) = split /\./;
|
|
my $pc_condition = $result->{$oid_cpqHePwrConvIndex . '.' . $_};
|
|
my $pc_redundant = $result->{$oid_cpqHePwrConvRedundant . '.' . $_};
|
|
my $pc_redundantgroup = defined($result->{$oid_cpqHePwrConvRedundantGroupId . '.' . $_}) ? $result->{$oid_cpqHePwrConvRedundantGroupId . '.' . $_} : 'undefined';
|
|
|
|
$self->{components}->{pc}->{total}++;
|
|
$self->{output}->output_add(long_msg => sprintf("powerconverter %d status is %s [chassis: %s, redundance: %s, redundant group: %s].",
|
|
$pc_index, ${$conditions{$pc_condition}}[0],
|
|
$pc_chassis, $redundant_map{$pc_redundant}, $pc_redundantgroup
|
|
));
|
|
if ($pc_condition != 2) {
|
|
$self->{output}->output_add(severity => ${$conditions{$pc_condition}}[1],
|
|
short_msg => sprintf("powerconverter %d status is %s",
|
|
$pc_index, ${$conditions{$pc_condition}}[0]));
|
|
}
|
|
}
|
|
}
|
|
|
|
1; |