diff --git a/doc/10-icinga-template-library.md b/doc/10-icinga-template-library.md
index f0b4da694..b7b2cee09 100644
--- a/doc/10-icinga-template-library.md
+++ b/doc/10-icinga-template-library.md
@@ -2601,18 +2601,18 @@ openmanage_timeout | **Optional.** Plugin timeout in seconds [default=30]
openmanage_vdisk_critical | **Optional.** Make any alerts on virtual disks critical
openmanage_warning | **Optional.** Custom temperature warning limits
-#### temp
+#### lmsensors
-The [check_temp](https://github.com/jackbenny/check_temp) plugin,
+The [check_lmsensors](https://github.com/jackbenny/check_temp) plugin,
uses the `lm-sensors` binary to monitor temperature sensors.
Custom attributes passed as [command parameters](03-monitoring-basics.md#command-passing-parameters):
Name | Description
------------------------|----------------------------------------------------------------------------------
-temp_warning | **Required.** Exit with WARNING status if above INTEGER degrees
-temp_critical | **Required.** Exit with CRITICAL status if above INTEGER degrees
-temp_sensor | **Optional.** Set what to monitor, for example CPU or MB (or M/B). Check sensors for the correct word. Default is CPU.
+lmsensors_warning | **Required.** Exit with WARNING status if above INTEGER degrees
+lmsensors_critical | **Required.** Exit with CRITICAL status if above INTEGER degrees
+lmsensors_sensor | **Optional.** Set what to monitor, for example CPU or MB (or M/B). Check sensors for the correct word. Default is CPU.
#### hddtemp
diff --git a/itl/plugins-contrib.d/hardware.conf b/itl/plugins-contrib.d/hardware.conf
index 46ce83604..29d7b91b5 100644
--- a/itl/plugins-contrib.d/hardware.conf
+++ b/itl/plugins-contrib.d/hardware.conf
@@ -205,29 +205,29 @@ object CheckCommand "openmanage" {
}
}
-object CheckCommand "temp" {
- command = [ PluginDir + "/check_temp" ]
+object CheckCommand "lmsensors" {
+ command = [ PluginDir + "/check_lmsensors" ]
arguments = {
"-w" = {
- value = "$temp_warning$"
+ value = "$lmsensors_warning$"
description = "Exit with WARNING status if above INTEGER degrees"
required = true
}
"-c" = {
- value = "$temp_critical$"
+ value = "$lmsensors_critical$"
description = "Exit with CRITICAL status if above INTEGER degrees"
required = true
}
"--sensor" = {
- value = "$temp_sensor$"
+ value = "$lmsensors_sensor$"
description = "Set what to monitor, for example CPU or MB (or M/B). Check sensors for the correct word. Default is CPU."
}
}
- vars.temp_warning = "75"
- vars.temp_critical = "80"
- vars.temp_sensor = "Core"
+ vars.lmsensors_warning = "75"
+ vars.lmsensors_critical = "80"
+ vars.lmsensors_sensor = "Core"
}
object CheckCommand "hddtemp" {