Julian Brost 13ea635188 Don't trigger a fixed downtime like a flexible one
When creating a fixed downtime that starts immediately while the checkable is
in a non-OK state, previously the code path for flexible downtimes was used to
trigger this downtime. This is fixed by this commit which resolves two issued:

1. Missing downtime start notification: notifications work differently for
   fixed and flexible downtimes. This resulted in missing downtime start
   notifications under the conditions described above.
2. Incorrect downtime trigger time: this code path would incorrectly assume the
   timestamp of the last checkable as the trigger time which is incorrect for
   fixed downtimes.