pandorafms/pandora_console/attachment/mibs/RFC1318-MIB

254 lines
8.7 KiB
Plaintext
Raw Normal View History

2023-05-29 11:47:25 +02:00
-- Changes to RFC1318 (Parallel Printer MIB)
-- No changes needed.
-- dperkins@scruznet.com
RFC1318-MIB DEFINITIONS ::= BEGIN
IMPORTS
Counter
FROM RFC1155-SMI
transmission
FROM RFC1213-MIB
OBJECT-TYPE
FROM RFC-1212;
-- this is the MIB module for Parallel-printer-like
-- hardware devices
para OBJECT IDENTIFIER ::= { transmission 34 }
-- the generic Parallel-printer-like group
-- Implementation of this group is mandatory for all
-- systems that have Parallel-printer-like hardware
-- ports supporting higher level services such as
-- character streams
paraNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of ports (regardless of their current
state) in the Parallel-printer-like port table."
::= { para 1 }
-- the Parallel-printer-like Port table
paraPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF ParaPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of port entries. The number of entries is
given by the value of paraNumber."
::= { para 2 }
paraPortEntry OBJECT-TYPE
SYNTAX ParaPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Status and parameter values for a port."
INDEX { paraPortIndex }
::= { paraPortTable 1 }
ParaPortEntry ::=
SEQUENCE {
paraPortIndex
INTEGER,
paraPortType
INTEGER,
paraPortInSigNumber
INTEGER,
paraPortOutSigNumber
INTEGER
}
paraPortIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A unique value for each port. Its value ranges
between 1 and the value of paraNumber. By
convention and if possible, hardware port numbers
map directly to external connectors. The value for
each port must remain constant at least from one
re-initialization of the network management agent to
the next."
::= { paraPortEntry 1 }
paraPortType OBJECT-TYPE
SYNTAX INTEGER {
other(1),
centronics(2),
dataproducts(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The port's hardware type."
::= { paraPortEntry 2 }
paraPortInSigNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of input signals for the port in the
input signal table (paraPortInSigTable). The table
contains entries only for those signals the software
can detect."
::= { paraPortEntry 3 }
paraPortOutSigNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of output signals for the port in the
output signal table (paraPortOutSigTable). The
table contains entries only for those signals the
software can assert."
::= { paraPortEntry 4 }
-- the Input Signal table
paraInSigTable OBJECT-TYPE
SYNTAX SEQUENCE OF ParaInSigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of port input control signal entries."
::= { para 3 }
paraInSigEntry OBJECT-TYPE
SYNTAX ParaInSigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Input control signal status for a hardware port."
INDEX { paraInSigPortIndex, paraInSigName }
::= { paraInSigTable 1 }
ParaInSigEntry ::=
SEQUENCE {
paraInSigPortIndex
INTEGER,
paraInSigName
INTEGER,
paraInSigState
INTEGER,
paraInSigChanges
Counter
}
paraInSigPortIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of paraPortIndex for the port to which
this entry belongs."
::= { paraInSigEntry 1 }
paraInSigName OBJECT-TYPE
SYNTAX INTEGER { power(1), online(2), busy(3),
paperout(4), fault(5) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Identification of a hardware signal."
::= { paraInSigEntry 2 }
paraInSigState OBJECT-TYPE
SYNTAX INTEGER { none(1), on(2), off(3) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current signal state."
::= { paraInSigEntry 3 }
paraInSigChanges OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of times the signal has changed from
'on' to 'off' or from 'off' to 'on'."
::= { paraInSigEntry 4 }
-- the Output Signal table
paraOutSigTable OBJECT-TYPE
SYNTAX SEQUENCE OF ParaOutSigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of port output control signal entries."
::= { para 4 }
paraOutSigEntry OBJECT-TYPE
SYNTAX ParaOutSigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Output control signal status for a hardware port."
INDEX { paraOutSigPortIndex, paraOutSigName }
::= { paraOutSigTable 1 }
ParaOutSigEntry ::=
SEQUENCE {
paraOutSigPortIndex
INTEGER,
paraOutSigName
INTEGER,
paraOutSigState
INTEGER,
paraOutSigChanges
Counter
}
paraOutSigPortIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of paraPortIndex for the port to which
this entry belongs."
::= { paraOutSigEntry 1 }
paraOutSigName OBJECT-TYPE
SYNTAX INTEGER { power(1), online(2), busy(3),
paperout(4), fault(5) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Identification of a hardware signal."
::= { paraOutSigEntry 2 }
paraOutSigState OBJECT-TYPE
SYNTAX INTEGER { none(1), on(2), off(3) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current signal state."
::= { paraOutSigEntry 3 }
paraOutSigChanges OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of times the signal has changed from
'on' to 'off' or from 'off' to 'on'."
::= { paraOutSigEntry 4 }