254 lines
8.7 KiB
Plaintext
254 lines
8.7 KiB
Plaintext
|
-- Changes to RFC1318 (Parallel Printer MIB)
|
||
|
-- No changes needed.
|
||
|
-- dperkins@scruznet.com
|
||
|
|
||
|
|
||
|
RFC1318-MIB DEFINITIONS ::= BEGIN
|
||
|
|
||
|
IMPORTS
|
||
|
Counter
|
||
|
FROM RFC1155-SMI
|
||
|
transmission
|
||
|
FROM RFC1213-MIB
|
||
|
OBJECT-TYPE
|
||
|
FROM RFC-1212;
|
||
|
|
||
|
-- this is the MIB module for Parallel-printer-like
|
||
|
-- hardware devices
|
||
|
|
||
|
para OBJECT IDENTIFIER ::= { transmission 34 }
|
||
|
|
||
|
-- the generic Parallel-printer-like group
|
||
|
|
||
|
-- Implementation of this group is mandatory for all
|
||
|
-- systems that have Parallel-printer-like hardware
|
||
|
-- ports supporting higher level services such as
|
||
|
-- character streams
|
||
|
|
||
|
paraNumber OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The number of ports (regardless of their current
|
||
|
state) in the Parallel-printer-like port table."
|
||
|
::= { para 1 }
|
||
|
|
||
|
|
||
|
-- the Parallel-printer-like Port table
|
||
|
|
||
|
paraPortTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF ParaPortEntry
|
||
|
ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"A list of port entries. The number of entries is
|
||
|
given by the value of paraNumber."
|
||
|
::= { para 2 }
|
||
|
|
||
|
|
||
|
paraPortEntry OBJECT-TYPE
|
||
|
SYNTAX ParaPortEntry
|
||
|
ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Status and parameter values for a port."
|
||
|
INDEX { paraPortIndex }
|
||
|
::= { paraPortTable 1 }
|
||
|
|
||
|
ParaPortEntry ::=
|
||
|
SEQUENCE {
|
||
|
paraPortIndex
|
||
|
INTEGER,
|
||
|
paraPortType
|
||
|
INTEGER,
|
||
|
paraPortInSigNumber
|
||
|
INTEGER,
|
||
|
paraPortOutSigNumber
|
||
|
INTEGER
|
||
|
}
|
||
|
|
||
|
paraPortIndex OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"A unique value for each port. Its value ranges
|
||
|
between 1 and the value of paraNumber. By
|
||
|
convention and if possible, hardware port numbers
|
||
|
map directly to external connectors. The value for
|
||
|
each port must remain constant at least from one
|
||
|
re-initialization of the network management agent to
|
||
|
the next."
|
||
|
::= { paraPortEntry 1 }
|
||
|
|
||
|
paraPortType OBJECT-TYPE
|
||
|
SYNTAX INTEGER {
|
||
|
other(1),
|
||
|
centronics(2),
|
||
|
dataproducts(3)
|
||
|
}
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The port's hardware type."
|
||
|
::= { paraPortEntry 2 }
|
||
|
|
||
|
paraPortInSigNumber OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The number of input signals for the port in the
|
||
|
input signal table (paraPortInSigTable). The table
|
||
|
contains entries only for those signals the software
|
||
|
can detect."
|
||
|
::= { paraPortEntry 3 }
|
||
|
|
||
|
paraPortOutSigNumber OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The number of output signals for the port in the
|
||
|
output signal table (paraPortOutSigTable). The
|
||
|
table contains entries only for those signals the
|
||
|
software can assert."
|
||
|
::= { paraPortEntry 4 }
|
||
|
|
||
|
|
||
|
-- the Input Signal table
|
||
|
|
||
|
paraInSigTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF ParaInSigEntry
|
||
|
ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"A list of port input control signal entries."
|
||
|
::= { para 3 }
|
||
|
|
||
|
paraInSigEntry OBJECT-TYPE
|
||
|
SYNTAX ParaInSigEntry
|
||
|
ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Input control signal status for a hardware port."
|
||
|
INDEX { paraInSigPortIndex, paraInSigName }
|
||
|
::= { paraInSigTable 1 }
|
||
|
|
||
|
ParaInSigEntry ::=
|
||
|
SEQUENCE {
|
||
|
paraInSigPortIndex
|
||
|
INTEGER,
|
||
|
paraInSigName
|
||
|
INTEGER,
|
||
|
paraInSigState
|
||
|
INTEGER,
|
||
|
paraInSigChanges
|
||
|
Counter
|
||
|
}
|
||
|
|
||
|
paraInSigPortIndex OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The value of paraPortIndex for the port to which
|
||
|
this entry belongs."
|
||
|
::= { paraInSigEntry 1 }
|
||
|
|
||
|
paraInSigName OBJECT-TYPE
|
||
|
SYNTAX INTEGER { power(1), online(2), busy(3),
|
||
|
paperout(4), fault(5) }
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Identification of a hardware signal."
|
||
|
::= { paraInSigEntry 2 }
|
||
|
|
||
|
paraInSigState OBJECT-TYPE
|
||
|
SYNTAX INTEGER { none(1), on(2), off(3) }
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The current signal state."
|
||
|
::= { paraInSigEntry 3 }
|
||
|
|
||
|
paraInSigChanges OBJECT-TYPE
|
||
|
SYNTAX Counter
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The number of times the signal has changed from
|
||
|
'on' to 'off' or from 'off' to 'on'."
|
||
|
::= { paraInSigEntry 4 }
|
||
|
|
||
|
|
||
|
-- the Output Signal table
|
||
|
|
||
|
paraOutSigTable OBJECT-TYPE
|
||
|
SYNTAX SEQUENCE OF ParaOutSigEntry
|
||
|
ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"A list of port output control signal entries."
|
||
|
::= { para 4 }
|
||
|
|
||
|
paraOutSigEntry OBJECT-TYPE
|
||
|
SYNTAX ParaOutSigEntry
|
||
|
ACCESS not-accessible
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Output control signal status for a hardware port."
|
||
|
INDEX { paraOutSigPortIndex, paraOutSigName }
|
||
|
::= { paraOutSigTable 1 }
|
||
|
|
||
|
ParaOutSigEntry ::=
|
||
|
SEQUENCE {
|
||
|
paraOutSigPortIndex
|
||
|
INTEGER,
|
||
|
paraOutSigName
|
||
|
INTEGER,
|
||
|
paraOutSigState
|
||
|
INTEGER,
|
||
|
paraOutSigChanges
|
||
|
Counter
|
||
|
}
|
||
|
|
||
|
paraOutSigPortIndex OBJECT-TYPE
|
||
|
SYNTAX INTEGER
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The value of paraPortIndex for the port to which
|
||
|
this entry belongs."
|
||
|
::= { paraOutSigEntry 1 }
|
||
|
|
||
|
paraOutSigName OBJECT-TYPE
|
||
|
SYNTAX INTEGER { power(1), online(2), busy(3),
|
||
|
paperout(4), fault(5) }
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"Identification of a hardware signal."
|
||
|
::= { paraOutSigEntry 2 }
|
||
|
|
||
|
paraOutSigState OBJECT-TYPE
|
||
|
SYNTAX INTEGER { none(1), on(2), off(3) }
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The current signal state."
|
||
|
::= { paraOutSigEntry 3 }
|
||
|
|
||
|
paraOutSigChanges OBJECT-TYPE
|
||
|
SYNTAX Counter
|
||
|
ACCESS read-only
|
||
|
STATUS mandatory
|
||
|
DESCRIPTION
|
||
|
"The number of times the signal has changed from
|
||
|
'on' to 'off' or from 'off' to 'on'."
|
||
|
::= { paraOutSigEntry 4 }
|
||
|
|
||
|
END
|