pandorafms/pandora_console/attachment/mibs/DECNET-PHIV-MIB

3042 lines
101 KiB
Plaintext
Raw Normal View History

2023-05-29 11:47:25 +02:00
-- Changes for RFC 1559 (DECnet Phase IV MIB)
-- Fixed the following so that the syntax specified for them
-- in SEQENCES matches the syntax specified in the
-- OBJECT-TYPE macro:
-- phivCircuitLineIndex in sequence PhivCircuitParametersEntry
-- phivDDCMPCircuitAdjNodeAddr in sequence PhivDDCMPCircuitParametersEntry
-- phivDDCMPCircuitSelectTimeouts in sequence PhivDDCMPCircuitCountEntry
-- phivCountersCountSendFailure in sequence PhivCountersCountEntry
-- phivCountersCountCollDetectFailure in sequence PhivCountersCountEntry
-- phivCountersCountReceiveFailure in sequence PhivCountersCountEntry
-- phivCountersCountUnrecFrameDest in sequence PhivCountersCountEntry
-- phivCountersCountDataOver in sequence PhivCountersCountEntry
-- phivCountersCountSysBuffUnav in sequence PhivCountersCountEntry
-- phivCountersCountUsrBuffUnav in sequence PhivCountersCountEntry
-- dperkins@scruznet.com
DECNET-PHIV-MIB DEFINITIONS ::= BEGIN
IMPORTS
Gauge
FROM RFC1155-SMI
OBJECT-TYPE
FROM RFC-1212
mib-2, DisplayString
FROM RFC1213-MIB;
-- DECNet Phase-IV MIB
phiv OBJECT IDENTIFIER ::= { mib-2 18 }
-- textual conventions
PhivAddr ::= OCTET STRING (SIZE (2))
-- This data type is intended as a short word representation of
-- standard DECnet Phase IV addresses. DECnet addresses are
-- hierarchically structured numbers assigned to a particular
-- DECnet node. The address is structured so that the area
-- number is contained in the most significant 6 bits of the
-- first octet. The next 2 bits of the first octet contain
-- the first two bits of the host address. The remainder of
-- the host address is contained in the second octet.
PhivCounter ::= INTEGER
-- This data type has been created for DECnet counters. These
-- counters latch at their maximum specified value until either
-- the system is restarted, or they are reset to zero by the user
-- or management software.
InterfaceIndex ::= INTEGER
-- The range of ifIndex, i.e., (1..2147483647)
-- groups in the decnetiv mib
phivSystem OBJECT IDENTIFIER ::= { phiv 1 }
phivManagement OBJECT IDENTIFIER ::= { phiv 2 }
session OBJECT IDENTIFIER ::= { phiv 3 }
end OBJECT IDENTIFIER ::= { phiv 4 }
routing OBJECT IDENTIFIER ::= { phiv 5 }
circuit OBJECT IDENTIFIER ::= { phiv 6 }
ddcmp OBJECT IDENTIFIER ::= { phiv 7 }
control OBJECT IDENTIFIER ::= { phiv 8 }
ethernet OBJECT IDENTIFIER ::= { phiv 9 }
counters OBJECT IDENTIFIER ::= { phiv 10 }
adjacency OBJECT IDENTIFIER ::= { phiv 11 }
line OBJECT IDENTIFIER ::= { phiv 12 }
nonBroadcastLine OBJECT IDENTIFIER ::= { phiv 14 }
area OBJECT IDENTIFIER ::= { phiv 15 }
-- System Group
-- The implementation of the System Group is mandatory for
-- all systems.
phivSystemState OBJECT-TYPE
SYNTAX INTEGER {
on (1),
off (2),
shut (3),
restricted (4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This represents the operational state of the executor
node.
The possible states are:
ON Allows logical links.
OFF Allows no new links, terminates existing
links, and stops routing traffic through.
SHUT Allows no new logical links, does not
destroy existing logical links, and goes
to the OFF state when all logical links are
gone.
RESTRICTED Allows no new incoming logical links from
other nodes.
NOTE: These values are incremented by one compared to
the standard DECnet values in order to maintain
compliance with RFC 1155)."
::= { phivSystem 1 }
phivExecIdent OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This is a text string that describes the executor node
(for example, 'Research Lab'). The string is up to 32
characters of any type."
::= { phivSystem 2 }
-- Network Management Group
-- The implementation of the Network Management Group is
-- mandatory for all systems which contain a DECnet-style
-- management version.
phivMgmtMgmtVers OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is the read-only Network Management Version,
consisting of the version number, the Engineering
Change Order (ECO) number, and the user ECO number
(for example, 3.0.0). This parameter applies to the
executor node only."
::= { phivManagement 1 }
-- Session Layer Group
-- The implementation of the Session Layer Group is optional.
-- A system can be said to implement this group if and only if
-- all objects in this group are implemented.
phivSessionSystemName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..6))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Name to be associated with the node identification.
Only one name can be assigned to a node address or a
circuit identification. No name should be used more than
once in a DECnet network. Node-name is one to six upper
case alphanumeric characters with at least one alpha
character. A length of 0 indicates no name."
::= { session 1 }
phivSessionInTimer OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This value represents the maximum duration between the
time a connect is received for a process at the
executor node and the time that process accepts or
rejects it. If the connect is not accepted or rejected
by the user within the number of seconds specified,
Session Control rejects it for the user. A value of 0
indicates no timer is running."
::= { session 2 }
phivSessionOutTimer OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This value represents the duration between the time the
executor requests a connect and the time that connect is
acknowledged by the destination node. If the connect is
not acknowledged within the number of seconds
specified, Session Control returns an error. A value of 0
indicates no timer is running."
::= { session 3 }
-- End Communication Layer Group
-- The implementation of the End Communication Layer Group is optional.
-- A system can be said to implement this group if and only if
-- all objects in this group are implemented.
-- Remote State Table
phivEndRemoteTable OBJECT-TYPE
SYNTAX SEQUENCE OF PhivEndRemoteEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Information about the state of sessions between the
node under study and the nodes found in the table."
::= { end 1 }
phivEndRemoteEntry OBJECT-TYPE
SYNTAX PhivEndRemoteEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Information about a particular remote node as seen
from the end communication layer."
INDEX { phivEndRemoteHostNodeID }
::= { phivEndRemoteTable 1 }
PhivEndRemoteEntry ::=
SEQUENCE {
phivEndRemoteHostNodeID
PhivAddr,
phivEndRemoteState
INTEGER,
phivEndCircuitIndex
INTEGER,
phivEndActiveLinks
INTEGER,
phivEndDelay
INTEGER
}
phivEndRemoteHostNodeID OBJECT-TYPE
SYNTAX PhivAddr -- OCTET STRING (SIZE (2))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value is the address of the remote node to be
evaluated."
::= { phivEndRemoteEntry 1 }
phivEndRemoteState OBJECT-TYPE
SYNTAX INTEGER {
on (1),
off (2),
shut (3),
restricted (4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This represents the operational state of the remote node
being evaluated.
The possible states are:
ON Allows logical links.
OFF Allows no new links, terminates existing
links, and stops routing traffic through.
SHUT Allows no new logical links, does not
destroy existing logical links, and goes
to the OFF state when all logical links are
gone.
RESTRICTED Allows no new incoming logical links from
other nodes.
NOTE: These values are incremented by one compared to
the standard DECnet values in order to maintain
compliance with RFC 1155."
::= { phivEndRemoteEntry 2 }
phivEndCircuitIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A unique index value for each known circuit used to
communicate with the remote node. This is the same
value as phivCircuitIndex."
::= { phivEndRemoteEntry 3 }
phivEndActiveLinks OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This read-only parameter represents the number of active
logical links from the executor to the destination node."
::= { phivEndRemoteEntry 4 }
phivEndDelay OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This read-only parameter is the average round trip
delay in seconds to the destination node. This
parameter is kept on a remote node basis."
::= { phivEndRemoteEntry 5 }
-- End System Counter Table
phivEndCountTable OBJECT-TYPE
SYNTAX SEQUENCE OF PhivEndCountEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Information about the counters associated with each end
system that is known to the entity. These counters
reflect totals from the perspective of the executor
node."
::= { end 2 }
phivEndCountEntry OBJECT-TYPE
SYNTAX PhivEndCountEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Information about a particular session between two end
systems."
INDEX { phivEndCountHostNodeID }
::= { phivEndCountTable 1 }
PhivEndCountEntry ::=
SEQUENCE {
phivEndCountHostNodeID
PhivAddr,
phivEndCountSecsLastZeroed
PhivCounter,
phivEndCountUsrBytesRec
PhivCounter,
phivEndCountUsrBytesSent
PhivCounter,
phivEndUCountUsrMessRec
PhivCounter,
phivEndCountUsrMessSent
PhivCounter,
phivEndCountTotalBytesRec
PhivCounter,
phivEndCountTotalBytesSent
PhivCounter,
phivEndCountTotalMessRec
PhivCounter,
phivEndCountTotalMessSent
PhivCounter,
phivEndCountConnectsRecd
PhivCounter,
phivEndCountConnectsSent
PhivCounter,
phivEndCountReponseTimeouts
PhivCounter,
phivEndCountRecdConnectResErrs
PhivCounter
}
phivEndCountHostNodeID OBJECT-TYPE
SYNTAX PhivAddr -- OCTET STRING (SIZE (2))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value is the address of the remote node to be
evaluated."
::= { phivEndCountEntry 1 }
phivEndCountSecsLastZeroed OBJECT-TYPE
SYNTAX PhivCounter (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value is the number of seconds that have elapsed
since the counters for the node in this table row were
last set to zero. This counter is located in the
network management layer, but is returned with the
end system information which follows."
::= { phivEndCountEntry 2 }
phivEndCountUsrBytesRec OBJECT-TYPE
SYNTAX PhivCounter (0..2147483647)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of user bytes received from the target host."
::= { phivEndCountEntry 3 }
phivEndCountUsrBytesSent OBJECT-TYPE
SYNTAX PhivCounter (0..2147483647)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of user bytes sent to the target host."
::= { phivEndCountEntry 4 }
phivEndUCountUsrMessRec OBJECT-TYPE
SYNTAX PhivCounter (0..2147483647)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of user messages received from the target host."
::= { phivEndCountEntry 5 }
phivEndCountUsrMessSent OBJECT-TYPE
SYNTAX PhivCounter (0..2147483647)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of user messages sent to the target host."
::= { phivEndCountEntry 6 }
phivEndCountTotalBytesRec OBJECT-TYPE
SYNTAX PhivCounter (0..2147483647)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of bytes received from the target host."
::= { phivEndCountEntry 7 }
phivEndCountTotalBytesSent OBJECT-TYPE
SYNTAX PhivCounter (0..2147483647)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of bytes sent to the target host."
::= { phivEndCountEntry 8 }
phivEndCountTotalMessRec OBJECT-TYPE
SYNTAX PhivCounter (0..2147483647)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of messages received from the target host."
::= { phivEndCountEntry 9 }
phivEndCountTotalMessSent OBJECT-TYPE
SYNTAX PhivCounter (0..2147483647)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of messages sent to the target host."
::= { phivEndCountEntry 10 }
phivEndCountConnectsRecd OBJECT-TYPE
SYNTAX PhivCounter (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of connects received from the target host."
::= { phivEndCountEntry 11 }
phivEndCountConnectsSent OBJECT-TYPE
SYNTAX PhivCounter (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of connects sent to the target host."
::= {phivEndCountEntry 12 }
phivEndCountReponseTimeouts OBJECT-TYPE
SYNTAX PhivCounter (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of response timeouts."
::= { phivEndCountEntry 13 }
phivEndCountRecdConnectResErrs OBJECT-TYPE
SYNTAX PhivCounter (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of received connect resource errors."
::= {phivEndCountEntry 14 }
-- additional End System objects
phivEndMaxLinks OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This value represents the maximum active logical
link count allowed for the executor."
::= { end 3 }
phivEndNSPVers OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This read-only parameter represents the version number
of the node End Communication S/W. The format is
version number, ECO, and user ECO, e.g., 4.1.0"
::= { end 4 }
phivEndRetransmitFactor OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This value represents the maximum number of times the
source End Communication at the executor node will
restart the retransmission timer when it expires. If
the number is exceeded, Session Control disconnects the
logical link for the user."
::= { end 5 }
phivEndDelayFact OBJECT-TYPE
SYNTAX INTEGER (1..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This is the number by which to multiply one sixteenth
of the estimated round trip delay to a node to set the
retransmission timer to that node."
::= { end 6 }
phivEndDelayWeight OBJECT-TYPE
SYNTAX INTEGER (1..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This number represents the weight to apply to a
current round trip delay estimate to a remote node
when updating the estimated round trip delay to a node.
On some systems the number must be 1 less than a power
of 2 for computational efficiency."
::= { end 7 }
phivEndInactivityTimer OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This value represents the maximum duration of inactivity
(no data in either direction) on a logical link before
the node checks to see if the logical link still works.
If no activity occurs within the minimum number of
seconds, End Communication generates artificial
traffic to test the link (End Communication
specification)."
::= { end 8 }
phivEndCountZeroCount OBJECT-TYPE
SYNTAX INTEGER {
other (1),
reset (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"When this value is set to 2, all of the counters in
the End System Counter Table are set to zero."
::= { end 9 }
phivEndMaxLinksActive OBJECT-TYPE
SYNTAX PhivCounter (0..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This value represents the high water mark for the
number of links that were active at any one time."
::= { end 10 }
-- Routing Layer Group
-- The implementation of the Routing Layer Group is mandatory for
-- all systems that implement level 1 routing layer
-- communications.
phivRouteBroadcastRouteTimer OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This value determines the maximum time in seconds
allowed between Routing updates on Ethernet
circuits. When this timer expired before a routing
update occurs, a routing update is forced. With a
standard calculation, Routing also uses this timer
to enforce a minimum delay between routing updates."
::= { routing 1 }
phivRouteBuffSize OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This parameter value determines the maximum size of
a Routing message. It therefore determines the maximum
size message that can be forwarded. This size includes
protocol overhead down to and including the End
Communication layer, plus a constant value of 6. (This
value of 6 is included to provide compatibility with
the parameter definition in Phase III, which included
the Routing overhead.) It does not include Routing or
Data link overhead (except for the constant value of
6). There is one buffer size for all circuits.
NOTE: The BUFFER SIZE defines the maximum size messages
that the Routing layer can forward. The SEGMENT BUFFER
SIZE (defined below) defines the maximum size messages
that the End Communication layer can transmit or
receive. The SEGMENT BUFFER SIZE is always less than
or equal to the BUFFER SIZE. Normally the two
parameters will be equal. They may be different to
allow the network manager to alter buffer sizes
on all nodes without interruption of service. They both
include an extra 6 bytes for compatibility with Phase
III."
::= { routing 2 }
phivRouteRoutingVers OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This read-only parameter identifies the executor node's
Routing version number. The format is version number,
ECO, and user ECO, e.g., 4.1.0"
::= { routing 3 }
phivRouteMaxAddr OBJECT-TYPE
SYNTAX INTEGER (1..1023)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This value represents the largest node number and,
therefore, number of nodes that can be known about
by the executor node's home area."
::= { routing 4 }
phivRouteMaxBdcastNonRouters OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This value represents the maximum total number of
nonrouters the executor node can have on its Ethernet
circuits."
::= { routing 5 }
phivRouteMaxBdcastRouters OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This value represents the maximum total number of
routers the executor node can have on its Ethernet
circuits."
::= { routing 6 }
phivRouteMaxBuffs OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This value represents the maximum number of transmit
buffers that Routing may use for all circuits."
::= { routing 7 }
phivRouteMaxCircuits OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This value represents the maximum number of Routing
circuits that the executor node can know about."
::= { routing 8 }
phivRouteMaxCost OBJECT-TYPE
SYNTAX INTEGER (1..1022)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This value represents the maximum total path cost
allowed from the executor to any node within an area.
The path cost is the sum of the circuit costs along
a path between two nodes. This parameter defines the
point where the executor node's Routing routing
decision algorithm declares another node unreachable
because the cost of the least costly path to the
other node is excessive. For correct operation, this
parameter must not be less than the maximum path cost
of the network."
::= { routing 9 }
phivRouteMaxHops OBJECT-TYPE
SYNTAX INTEGER (1..30)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This value represents the maximum number of routing hops
allowable from the executor to any other reachable node
within an area. (A hop is the logical distance over a
circuit between two adjacent nodes.) This parameter
defines the point where the executor node's Routing
routing decision algorithm declares another node
unreachable because the length of the shortest path
between the two nodes is too long. For correct
operation, this parameter must not be less than the
network diameter. (The network diameter is the
reachability distance between the two nodes of the
network having the greatest reachability distance,
where reachability distance is the length the shortest
path between a given pair of nodes.)"
::= { routing 10 }
phivRouteMaxVisits OBJECT-TYPE
SYNTAX INTEGER (1..63)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This value represents the maximum number of nodes a
message coming into the executor node can have visited.
If the message is not for this node and the MAXIMUM
VISITS number is exceeded, the message is discarded.
The MAXIMUM VISITS parameter defines the point where
the packet lifetime control algorithm discards
a packet that has traversed too many nodes. For correct
operation, this parameter must not be less than the
maximum path length of the network. (The maximum path
length is the routing distance between the two nodes of
the network having the greatest routing distance, where
routing distance is the length of the least costly
path between a given pair of nodes.)"
::= { routing 11 }
phivRouteRoutingTimer OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This value determines the maximum time in seconds
allowed between Routing updates on non-Ethernet
circuits. When this timer expires before a routing
update occurs, a routing update is forced."
::= { routing 12 }
phivRouteSegBuffSize OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This parameter value determines the maximum size of an
end-to-end segment. The size is a decimal integer in
the range 1-65535. This size is in bytes. This size
includes protocol overhead down to and including the
End Communication layer, plus a constant value of 6.
(This value of 6 is included to provide compatibility
with the BUFFER SIZE parameter definition.) It does not
include Routing or Data link overhead (except for the
constant value of 6)."
::= { routing 13 }
phivRouteType OBJECT-TYPE
SYNTAX INTEGER {
routing-III (1),
nonrouting-III (2),
area (3),
routing-IV (4),
nonrouting-IV (5)
}
ACCESS read-only
STATUS obsolete
DESCRIPTION
"This parameter indicates the type of the executor
node. The node-type is one of the following:
routing-III
nonrouting-III
routing-IV
ronrouting-IV
area
A routing node has full routing capability. A
nonrouting node contains a subset of the Routing
routing modules. The III and IV indicate the DNA
phase of the node. Nonrouting nodes can deliver
and receive packets to and from any node, but cannot
route packets from other nodes through to other nodes.
An area node routes between areas. Refer to the Routing
specification for details.
For adjacent nodes, this is a read-only parameter that
indicates the type of the reachable adjacent node.
NOTE: The ROUTING-III and NONROUTING-III values are
incremented by one compared to the standard DECnet
values in order to maintain compliance with RFC 1155)"
::= { routing 14 }
phivRouteCountAgedPktLoss OBJECT-TYPE
SYNTAX PhivCounter (0..127)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of aged packet losses."
::= { routing 15 }
phivRouteCountNodeUnrPktLoss OBJECT-TYPE
SYNTAX PhivCounter (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of node unreachable packet losses."
::= { routing 16 }
phivRouteCountOutRngePktLoss OBJECT-TYPE
SYNTAX PhivCounter (0..127)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of node out-of-range packet losses."
::= { routing 17 }
phivRouteCountOverSzePktLoss OBJECT-TYPE
SYNTAX PhivCounter (0..127)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of Oversized packet losses."
::= { routing 18 }
phivRouteCountPacketFmtErr OBJECT-TYPE
SYNTAX PhivCounter (0..127)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of packet format errors."
::= { routing 19 }
phivRouteCountPtlRteUpdtLoss OBJECT-TYPE
SYNTAX PhivCounter (0..127)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of partial routing update losses."
::= { routing 20 }
phivRouteCountVerifReject OBJECT-TYPE
SYNTAX PhivCounter (0..127)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of verification rejects."
::= { routing 21 }
-- Level 1 Routing Table
phivLevel1RouteTable OBJECT-TYPE
SYNTAX SEQUENCE OF PhivLevel1RouteEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Information about the currently known DECnet Phase
IV Routes."
::= { routing 22 }
phivLevel1RouteEntry OBJECT-TYPE
SYNTAX PhivLevel1RouteEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Information about the currently known DECnet Phase
IV Routes."
INDEX { phivLevel1RouteNodeAddr }
::= { phivLevel1RouteTable 1 }
PhivLevel1RouteEntry ::=
SEQUENCE {
phivLevel1RouteNodeAddr
PhivAddr,
phivLevel1RouteCircuitIndex
INTEGER,
phivLevel1RouteCost
INTEGER,
phivLevel1RouteHops
INTEGER,
phivLevel1RouteNextNode
PhivAddr
}
phivLevel1RouteNodeAddr OBJECT-TYPE
SYNTAX PhivAddr -- OCTET STRING (SIZE (2))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value is the address of the node about which
routing information is contained in this level 1
routing table."
::= { phivLevel1RouteEntry 1 }
phivLevel1RouteCircuitIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A unique index value for each known circuit. This is
the index to the circuit state table and is the same
value as phivCircuitIndex."
::= { phivLevel1RouteEntry 2 }
phivLevel1RouteCost OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This read-only parameter represents the total cost
over the current path to the destination node. Cost is
a positive integer value associated with using a
circuit. Routing routes messages (data) along the path
between two nodes with the smallest cost. COST is kept
on a remote node basis."
::= { phivLevel1RouteEntry 3 }
phivLevel1RouteHops OBJECT-TYPE
SYNTAX INTEGER (0..127)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This read-only parameter represents the number of hops
over to a destination node. A hop is Routing value
representing the logical distance between two nodes in
a network. HOPS is kept on a remote node basis."
::= { phivLevel1RouteEntry 4 }
phivLevel1RouteNextNode OBJECT-TYPE
SYNTAX PhivAddr -- OCTET STRING (SIZE (2))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This read-only value indicates the next node on the
circuit used to get to the node under scrutiny
(next hop)."
::= { phivLevel1RouteEntry 5 }
-- Additional routing parameters
phivRouteCountZeroCount OBJECT-TYPE
SYNTAX INTEGER {
other (1),
reset (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"When this value is set to 2, the following objects are
set to Zero: phivRouteCountAgedPktLoss,
phivRouteCountNodeUnrPktLoss,
phivRouteCountOutRngePktLoss,
phivRouteCountOverSzePktLoss,
phivRouteCountPacketFmtErr,
phivRouteCountPtlRteUpdtLoss, and
phivRouteCountVerifReject."
::= { routing 23 }
phivRouteSystemAddr OBJECT-TYPE
SYNTAX PhivAddr -- OCTET STRING (SIZE (2))
ACCESS read-only
STATUS obsolete
DESCRIPTION
"DECnet Phase IV node address."
::= { routing 24 }
phivRouteRoutingType OBJECT-TYPE
SYNTAX INTEGER {
routing-III (1),
nonrouting-III (2),
area (3),
routing-IV (4),
nonrouting-IV (5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This read-write parameter indicates the type of the executor
node. The node-type is one of the following:
routing-III
nonrouting-III
routing-IV
ronrouting-IV
area
A routing node has full routing capability. A
nonrouting node contains a subset of the Routing
routing modules. The III and IV indicate the DNA
phase of the node. Nonrouting nodes can deliver
and receive packets to and from any node, but cannot
route packets from other nodes through to other nodes.
An area node routes between areas. Refer to the Routing
specification for details.
For adjacent nodes, this is a read-only parameter that
indicates the type of the reachable adjacent node.
NOTE: The ROUTING-III and NONROUTING-III values are
incremented by one compared to the standard DECnet
values in order to maintain compliance with RFC 1155)"
::= { routing 25 }
phivRouteSystemAddress OBJECT-TYPE
SYNTAX PhivAddr -- OCTET STRING (SIZE (2))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DECnet Phase IV node address."
::= { routing 26 }
-- Circuit Group
-- The implementation of the Circuit Group is mandatory for
-- all systems.
-- Circuit Parameters Table
phivCircuitParametersTable OBJECT-TYPE
SYNTAX SEQUENCE OF PhivCircuitParametersEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Information about the parameters associated with all
circuits currently known."
::= {circuit 1 }
phivCircuitParametersEntry OBJECT-TYPE
SYNTAX PhivCircuitParametersEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Parameters information about all circuits currently
known."
INDEX { phivCircuitIndex }
::= { phivCircuitParametersTable 1 }
PhivCircuitParametersEntry ::=
SEQUENCE {
phivCircuitIndex
INTEGER,
phivCircuitLineIndex
InterfaceIndex,
phivCircuitCommonState
INTEGER,
phivCircuitCommonSubState
INTEGER,
phivCircuitCommonName
DisplayString,
phivCircuitExecRecallTimer
INTEGER,
phivCircuitCommonType
INTEGER,
phivCircuitService
INTEGER,
phivCircuitExecCost
INTEGER,
phivCircuitExecHelloTimer
INTEGER
}
phivCircuitIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A unique index value for each known circuit."
::= { phivCircuitParametersEntry 1 }
phivCircuitLineIndex OBJECT-TYPE
SYNTAX InterfaceIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The line on which this circuit is active. This is
the same as the ifIndex."
::= { phivCircuitParametersEntry 2 }
phivCircuitCommonState OBJECT-TYPE
SYNTAX INTEGER {
on (1),
off (2),
service (3),
cleared (4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This value represents the circuit's Network Management
operational state. NOTE: These values are incremented
by one compared to the standard DECnet values in order
to maintain compliance with RFC 1155."
::= { phivCircuitParametersEntry 3 }
phivCircuitCommonSubState OBJECT-TYPE
SYNTAX INTEGER {
starting (1),
reflecting (2),
looping (3),
loading (4),
dumping (5),
triggering (6),
autoservice (7),
autoloading (8),
autodumping (9),
autotriggering (10),
synchronizing (11),
failed (12),
running (13)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value represents the circuit's Network Management
operational and service substate. NOTE: These values are
incremented by one compared to the standard DECnet values
in order to maintain compliance with RFC 1155."
::= { phivCircuitParametersEntry 4 }
phivCircuitCommonName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The name of the circuit entry in the table, for example,
SVA-0 or in a level 2 router ASYNC-8 or ETHER-1)."
::= { phivCircuitParametersEntry 5 }
phivCircuitExecRecallTimer OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This parameter represents the minimum number of
seconds to wait before restarting the circuit. A
value of 0 indicates not timer is running."
::= { phivCircuitParametersEntry 6 }
phivCircuitCommonType OBJECT-TYPE
SYNTAX INTEGER {
ddcmp-point (1),
ddcmp-control (2),
ddcmp-tributary (3),
x25 (4),
ddcmp-dmc (5),
ethernet (6),
ci (7),
qp2-dte20 (8),
bisync (9),
other (14),
fddi (15)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Represents the type of the circuit. For X.25 circuits,
the value must be set to X25. For DDCMP and Ethernet
circuits it is read only and is the same value as the
protocol of the associated line.
NOTE: Values 1 - 5 are incremented by one compared to the
standard DECnet values in order to maintain compliance
with RFC 1155."
::= { phivCircuitParametersEntry 7 }
phivCircuitService OBJECT-TYPE
SYNTAX INTEGER {
enabled (1),
disabled (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This value indicates whether or not Network Management
allows service operations on a circuit. The values for
service-control are as follows:
ENABLED SERVICE state and/or service functions are
allowed.
DISABLED SERVICE state and/or service functions are not
allowed.
NOTE: These values are incremented by one compared to the
standard DECnet values in order to maintain compliance
with RFC 1155."
::= { phivCircuitParametersEntry 8 }
phivCircuitExecCost OBJECT-TYPE
SYNTAX INTEGER (1..25)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This value represents the routing cost of the circuit.
Routing sends messages along the path between two nodes
having the smallest cost."
::= { phivCircuitParametersEntry 9 }
phivCircuitExecHelloTimer OBJECT-TYPE
SYNTAX INTEGER (1..8191)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This value determines the frequency of Routing Hello
messages sent to the adjacent node on the circuit."
::= { phivCircuitParametersEntry 10 }
-- Circuit Counters Table
phivCircuitCountTable OBJECT-TYPE
SYNTAX SEQUENCE OF PhivCircuitCountEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Information about the counters associated with all
circuits currently known."
::= { circuit 2 }
phivCircuitCountEntry OBJECT-TYPE
SYNTAX PhivCircuitCountEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Counter information about all circuits currently known"
INDEX { phivCircuitIndex }
::= { phivCircuitCountTable 1 }
PhivCircuitCountEntry ::=
SEQUENCE {
phivCircuitCountSecLastZeroed
PhivCounter,
phivCircuitCountTermPacketsRecd
PhivCounter,
phivCircuitCountOriginPackSent
PhivCounter,
phivCircuitCountTermCongLoss
PhivCounter,
phivCircuitCountCorruptLoss
PhivCounter,
phivCircuitCountTransitPksRecd
PhivCounter,
phivCircuitCountTransitPkSent
PhivCounter,
phivCircuitCountTransitCongestLoss
PhivCounter,
phivCircuitCountCircuitDown
PhivCounter,
phivCircuitCountInitFailure
PhivCounter,
phivCircuitCountAdjDown
PhivCounter,
phivCircuitCountPeakAdj
PhivCounter,
phivCircuitCountBytesRecd
PhivCounter,
phivCircuitCountBytesSent
PhivCounter,
phivCircuitCountDataBlocksRecd
PhivCounter,
phivCircuitCountDataBlocksSent
PhivCounter,
phivCircuitCountUsrBuffUnav
PhivCounter
}
phivCircuitCountSecLastZeroed OBJECT-TYPE
SYNTAX PhivCounter (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of seconds since the circuit counters for this
circuit were last zeroed."
::= { phivCircuitCountEntry 1 }
phivCircuitCountTermPacketsRecd OBJECT-TYPE
SYNTAX PhivCounter (0..2147483647)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of terminating packets received on this circuit."
::= { phivCircuitCountEntry 2 }
phivCircuitCountOriginPackSent OBJECT-TYPE
SYNTAX PhivCounter (0..2147483647)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of originating packets sent on this circuit."
::= { phivCircuitCountEntry 3 }
phivCircuitCountTermCongLoss OBJECT-TYPE
SYNTAX PhivCounter (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of terminating congestion losses on this
circuit."
::= { phivCircuitCountEntry 4 }
phivCircuitCountCorruptLoss OBJECT-TYPE
SYNTAX PhivCounter (0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of corruption losses on this circuit."
::= { phivCircuitCountEntry 5 }
phivCircuitCountTransitPksRecd OBJECT-TYPE
SYNTAX PhivCounter (0..2147483647)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of Transit packets received on this circuit."
::= { phivCircuitCountEntry 6 }
phivCircuitCountTransitPkSent OBJECT-TYPE
SYNTAX PhivCounter (0..2147483647)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of transit packets sent on this circuit."
::= { phivCircuitCountEntry 7 }
phivCircuitCountTransitCongestLoss OBJECT-TYPE
SYNTAX PhivCounter (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of transit congestion losses on this circuit."
::= { phivCircuitCountEntry 8 }
phivCircuitCountCircuitDown OBJECT-TYPE
SYNTAX PhivCounter (0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of circuit downs on this circuit."
::= { phivCircuitCountEntry 9 }
phivCircuitCountInitFailure OBJECT-TYPE
SYNTAX PhivCounter (0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of Initialization failures on this circuit."
::= { phivCircuitCountEntry 10 }
phivCircuitCountAdjDown OBJECT-TYPE
SYNTAX PhivCounter (0..2147483647)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This counter indicates the number of adjacency losses
that result from any of the following:
Node listener timeout
Invalid data received at node listener
Unexpected control (initialization or verification)
message received
Routing message received with a checksum error
Node identification from a routing message or a
Hello message that is not the one expected Hello
message received indicating that connectivity
became one-way
Adjacency idled."
::= { phivCircuitCountEntry 11 }
phivCircuitCountPeakAdj OBJECT-TYPE
SYNTAX PhivCounter (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This counter indicates the maximum number of nodes
that are up on the circuit."
::= { phivCircuitCountEntry 12 }
phivCircuitCountBytesRecd OBJECT-TYPE
SYNTAX PhivCounter (0..2147483647)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of bytes received on this circuit."
::= { phivCircuitCountEntry 13 }
phivCircuitCountBytesSent OBJECT-TYPE
SYNTAX PhivCounter (0..2147483647)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of bytes sent on this circuit."
::= { phivCircuitCountEntry 14 }
phivCircuitCountDataBlocksRecd OBJECT-TYPE
SYNTAX PhivCounter (0..2147483647)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of data blocks received on this circuit."
::= { phivCircuitCountEntry 15 }
phivCircuitCountDataBlocksSent OBJECT-TYPE
SYNTAX PhivCounter (0..2147483647)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of data blocks sent on this circuit."
::= { phivCircuitCountEntry 16 }
phivCircuitCountUsrBuffUnav OBJECT-TYPE
SYNTAX PhivCounter (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of user buffer unavailable errors."
::= { phivCircuitCountEntry 17 }
-- Additional Circuit Parameters
phivCircuitOrigQueueLimit OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This parameter indicates the maximum number of
originating packets that may be outstanding on this
circuit. This does not include route-thru traffic."
::= { circuit 3 }
phivCircuitCountZeroCount OBJECT-TYPE
SYNTAX INTEGER {
other (1),
reset (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"When this value is set to 2, all of the counters in the
Circuit Counter Table are set to zero."
::= { circuit 4 }
-- DDCMP Circuit Group
-- The implementation of the DDCMP Circuit Group is optional.
-- A system can be said to implement this group if and only if
-- all objects in this group are implemented.
-- DDCMP Parameters Table
phivDDCMPCircuitParametersTable OBJECT-TYPE
SYNTAX SEQUENCE OF PhivDDCMPCircuitParametersEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Information about DDCMP circuit parameters."
::= { ddcmp 1}
phivDDCMPCircuitParametersEntry OBJECT-TYPE
SYNTAX PhivDDCMPCircuitParametersEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Parameters information about DDCMP circuits currently
known."
INDEX { phivDDCMPCircuitIndex }
::= { phivDDCMPCircuitParametersTable 1 }
PhivDDCMPCircuitParametersEntry ::=
SEQUENCE {
phivDDCMPCircuitIndex
INTEGER,
phivDDCMPCircuitAdjNodeAddr
PhivAddr,
phivDDCMPCircuitTributary
INTEGER
}
phivDDCMPCircuitIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A unique index value for each known DDCMP circuit.
This is the same value as phivCircuitIndex."
::= { phivDDCMPCircuitParametersEntry 1 }
phivDDCMPCircuitAdjNodeAddr OBJECT-TYPE
SYNTAX PhivAddr -- OCTET STRING (SIZE (2))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The address of the adjacent node."
::= { phivDDCMPCircuitParametersEntry 2 }
phivDDCMPCircuitTributary OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value represents the Data Link physical tributary
address of the circuit."
::= { phivDDCMPCircuitParametersEntry 3 }
-- DDCMP Circuit Counter Table
phivDDCMPCircuitCountTable OBJECT-TYPE
SYNTAX SEQUENCE OF PhivDDCMPCircuitCountEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Information about the DDCMP counters associated with all
circuits currently known."
::= { ddcmp 2 }
phivDDCMPCircuitCountEntry OBJECT-TYPE
SYNTAX PhivDDCMPCircuitCountEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Counter information about DDCMP circuits now known"
INDEX { phivCircuitIndex }
::= { phivDDCMPCircuitCountTable 1 }
PhivDDCMPCircuitCountEntry ::=
SEQUENCE {
phivDDCMPCircuitErrorsInbd
PhivCounter,
phivDDCMPCircuitErrorsOutbd
PhivCounter,
phivDDCMPCircuitRmteReplyTimeouts
PhivCounter,
phivDDCMPCircuitLocalReplyTimeouts
PhivCounter,
phivDDCMPCircuitRmteBuffErrors
PhivCounter,
phivDDCMPCircuitLocalBuffErrors
PhivCounter,
phivDDCMPCircuitSelectIntervalsElap
PhivCounter,
phivDDCMPCircuitSelectTimeouts
INTEGER
}
phivDDCMPCircuitErrorsInbd OBJECT-TYPE
SYNTAX PhivCounter (0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of Data errors inbound."
::= { phivDDCMPCircuitCountEntry 1 }
phivDDCMPCircuitErrorsOutbd OBJECT-TYPE
SYNTAX PhivCounter (0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of outbound data errors."
::= { phivDDCMPCircuitCountEntry 2 }
phivDDCMPCircuitRmteReplyTimeouts OBJECT-TYPE
SYNTAX PhivCounter (0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of remote reply timeouts."
::= { phivDDCMPCircuitCountEntry 3 }
phivDDCMPCircuitLocalReplyTimeouts OBJECT-TYPE
SYNTAX PhivCounter (0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of local Reply timeouts."
::= { phivDDCMPCircuitCountEntry 4 }
phivDDCMPCircuitRmteBuffErrors OBJECT-TYPE
SYNTAX PhivCounter (0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of remote reply time out errors."
::= { phivDDCMPCircuitCountEntry 5 }
phivDDCMPCircuitLocalBuffErrors OBJECT-TYPE
SYNTAX PhivCounter (0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of local buffer errors."
::= { phivDDCMPCircuitCountEntry 6 }
phivDDCMPCircuitSelectIntervalsElap OBJECT-TYPE
SYNTAX PhivCounter (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Selection intervals that have elapsed."
::= {phivDDCMPCircuitCountEntry 7 }
phivDDCMPCircuitSelectTimeouts OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of selection timeouts."
::= {phivDDCMPCircuitCountEntry 8 }
-- DDCMP Line Count Table
phivDDCMPLineCountTable OBJECT-TYPE
SYNTAX SEQUENCE OF PhivDDCMPLineCountEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The DDCMP Line Count Table."
::= { ddcmp 3 }
phivDDCMPLineCountEntry OBJECT-TYPE
SYNTAX PhivDDCMPLineCountEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"There is one entry in the table for each line."
INDEX { phivDDCMPLineCountIndex }
::= { phivDDCMPLineCountTable 1 }
PhivDDCMPLineCountEntry ::=
SEQUENCE {
phivDDCMPLineCountIndex
InterfaceIndex,
phivDDCMPLineCountDataErrsIn
PhivCounter,
phivDDCMPLineCountRmteStationErrs
PhivCounter,
phivDDCMPLineCountLocalStationErrs
PhivCounter
}
phivDDCMPLineCountIndex OBJECT-TYPE
SYNTAX InterfaceIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The line on which this entry's equivalence is
effective. The interface identified by a particular
value of this index is the same interface as
identified by the same value of phivLineIndex.
This value is the ifIndex."
::= { phivDDCMPLineCountEntry 1 }
phivDDCMPLineCountDataErrsIn OBJECT-TYPE
SYNTAX PhivCounter (0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of data errors inbound."
::= { phivDDCMPLineCountEntry 2 }
phivDDCMPLineCountRmteStationErrs OBJECT-TYPE
SYNTAX PhivCounter (0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of remote station errors."
::= { phivDDCMPLineCountEntry 3 }
phivDDCMPLineCountLocalStationErrs OBJECT-TYPE
SYNTAX PhivCounter (0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of local station errors."
::= { phivDDCMPLineCountEntry 4 }
-- DDCMP Multipoint Circuit Control Group
-- The implementation of the DDCMP Multipoint Circuit Control
-- Group is optional. A system can be said to implement this group
-- if and only if all objects in this group are implemented.
phivControlSchedTimer OBJECT-TYPE
SYNTAX INTEGER (50..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value represents the number of milliseconds
between recalculation of tributary polling priorities."
DEFVAL { 200 }
::= { control 1 }
phivControlDeadTimer OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value represents the number of milliseconds
between polls of one of the set of dead
tributaries."
DEFVAL { 10000 }
::= { control 2 }
phivControlDelayTimer OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value represents the minimum number of
milliseconds to delay between polls. The delay timer
limits the effect of a very fast control station on
slow tributaries."
::= { control 3 }
phivControlStreamTimer OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value represents the number of milliseconds a
tributary or a half duplex remote station is
allowed to hold the line.
NOTE: This parameter can also be applied to
half-duplex lines of type DDCMP POINT."
DEFVAL { 6000 }
::= { control 4 }
-- DDCMP Multipoint Circuit Control Parameters Table
phivControlParametersTable OBJECT-TYPE
SYNTAX SEQUENCE OF PhivControlParametersEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Information about control circuit parameters."
::= { control 5 }
phivControlParametersEntry OBJECT-TYPE
SYNTAX PhivControlParametersEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Parameters information about control circuits
currently known."
INDEX { phivControlCircuitIndex }
::= { phivControlParametersTable 1 }
PhivControlParametersEntry ::=
SEQUENCE {
phivControlCircuitIndex
INTEGER,
phivControlBabbleTimer
INTEGER,
phivControlMaxBuffs
INTEGER,
phivControlMaxTransmits
INTEGER,
phivControlDyingBase
INTEGER,
phivControlDyingIncrement
INTEGER,
phivControlDeadThreshold
INTEGER,
phivControlDyingThreshold
INTEGER,
phivControlInactTreshold
INTEGER,
phivControlPollingState
INTEGER,
phivControlPollingSubState
INTEGER,
phivControlTransTimer
INTEGER
}
phivControlCircuitIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A unique index value for each known multipoint
control circuit.
This is the same value as phivCircuitIndex."
::= { phivControlParametersEntry 1 }
phivControlBabbleTimer OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This value represents the number of milliseconds that a
selected tributary or remote half-duplex station is
allowed to transmit."
DEFVAL { 6000 }
::= { phivControlParametersEntry 2 }
phivControlMaxBuffs OBJECT-TYPE
SYNTAX INTEGER (1..254)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This value represents the maximum number of buffers the
tributary can use from a common buffer pool. If not
set, there is no common buffer pool and buffers are
explicitly supplied by the higher level. Count is a
decimal integer in the range 1-254."
::= { phivControlParametersEntry 3 }
phivControlMaxTransmits OBJECT-TYPE
SYNTAX INTEGER (1..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This value represents the maximum number of data
messages that can be transmitted at one time. Count
is a decimal integer in the range 1-255."
DEFVAL { 4 }
::= { phivControlParametersEntry 4 }
phivControlDyingBase OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This value represents the base priority to which a
tributary is reset each time it has been polled. A
separate base can be set for each of the indicated
polling states. Base is a decimal integer in the range
0-255. If not set, the defaults are: active, 255;
inactive, 0; and dying, 0."
::= { phivControlParametersEntry 5 }
phivControlDyingIncrement OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This value represents the increment added to the
tributary priority each time the scheduling timer
expires. If not set, the defaults are: active, 0;
inactive, 64; and dying, 16."
::= { phivControlParametersEntry 6 }
phivControlDeadThreshold OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This value represents the number of times to poll the
active, inactive, or dying tributary before changing
its polling state to dead because of receive timeouts.
Count is a decimal integer in the range 0-255."
DEFVAL { 8 }
::= { phivControlParametersEntry 7 }
phivControlDyingThreshold OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This value represents the number of times to poll the
active or inactive tributary before changing its
polling state to dying because of receive timeouts.
Count is a decimal integer in the range 0-255."
DEFVAL { 2 }
::= { phivControlParametersEntry 8 }
phivControlInactTreshold OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This value represents the number of times to poll the
active tributary before changing its polling state to
inactive because of no data response. Count is a
decimal integer in the range
0-255."
DEFVAL { 8 }
::= { phivControlParametersEntry 9 }
phivControlPollingState OBJECT-TYPE
SYNTAX INTEGER {
automatic (1),
active (2),
inactive (3),
dying (4),
dead (5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This value represents the state of the tributary
relative to the multipoint polling algorithm. If not
set the default is AUTOMATIC. The possible states are:
AUTOMATIC
The tributary's state is allowed to vary according to
the operation of the polling algorithm.
ACTIVE/INACTIVE/DYING/DEAD
The tributary is locked in the specified state.
NOTE: These values are incremented by one compared to
the standard DECnet values in order to maintain
compliance with RFC 1155."
::= { phivControlParametersEntry 10 }
phivControlPollingSubState OBJECT-TYPE
SYNTAX INTEGER {
active (1),
inactive (2),
dying (3),
dead (4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value represents the tributary's state as
determined by the polling algorithm. This applies
only when the polling state is AUTOMATIC and is
read-only to Network Management. Polling-substate is
one of ACTIVE, INACTIVE, DYING, or DEAD. It is
displayed as a tag on the polling state, for example:
AUTOMATIC-INACTIVE."
::= { phivControlParametersEntry 11 }
phivControlTransTimer OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This value represents the number of milliseconds to
delay between data message transmits. Milliseconds is
a decimal integer in the range 0-65535."
DEFVAL { 0 }
::= { phivControlParametersEntry 12 }
-- Ethernet Group
-- The implementation of the Ethernet Group is mandatory
-- for all systems which support ethernet links.
-- Ethernet Parameters Table
phivEthLinkParametersTable OBJECT-TYPE
SYNTAX SEQUENCE OF PhivEthLinkParametersEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Information about ethernet link parameters."
::= { ethernet 1}
phivEthLinkParametersEntry OBJECT-TYPE
SYNTAX PhivEthLinkParametersEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Parameter information about ethernet links currently
known."
INDEX { phivEthLinkIndex }
::= { phivEthLinkParametersTable 1 }
PhivEthLinkParametersEntry ::=
SEQUENCE {
phivEthLinkIndex
INTEGER,
phivEthDesigRouterNodeAddr
PhivAddr,
phivEthMaxRouters
INTEGER,
phivEthRouterPri
INTEGER,
phivEthHardwareAddr
OCTET STRING
}
phivEthLinkIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The circuit over which this links information is
collected. This is the same as phivCircuitIndex."
::= { phivEthLinkParametersEntry 1 }
phivEthDesigRouterNodeAddr OBJECT-TYPE
SYNTAX PhivAddr -- OCTET STRING (SIZE (2))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value is the address of the designated router."
::= { phivEthLinkParametersEntry 2 }
phivEthMaxRouters OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This parameter is the maximum number of routers (other
than the executor itself) allowed on the circuit by
Routing for circuits that are owned by the executor
node."
::= { phivEthLinkParametersEntry 3 }
phivEthRouterPri OBJECT-TYPE
SYNTAX INTEGER (0..127)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This parameter is the priority that this router is to
have in the selection of designated router for the
circuit on circuits that are owned by the executor
node."
DEFVAL { 64 }
::= { phivEthLinkParametersEntry 4 }
phivEthHardwareAddr OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (6))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This read-only parameter is the address that is
associated with the line device hardware as seen by
the DECnet Software. This value is not the same as
ifPhysAddress."
::= { phivEthLinkParametersEntry 5 }
-- Counters Group
-- The implementation of the Counters Group is optional.
-- A system can be said to implement this group if and only if
-- all objects in this group are implemented.
-- Counters Table
phivCountersCountTable OBJECT-TYPE
SYNTAX SEQUENCE OF PhivCountersCountEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Information about ethernet link counters."
::= { counters 1 }
phivCountersCountEntry OBJECT-TYPE
SYNTAX PhivCountersCountEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Counter information about ethernet links currently
known."
INDEX { phivCountersIndex }
::= { phivCountersCountTable 1 }
PhivCountersCountEntry ::=
SEQUENCE {
phivCountersIndex
InterfaceIndex,
phivCountersCountBytesRecd
PhivCounter,
phivCountersCountBytesSent
PhivCounter,
phivCountersCountDataBlocksRecd
PhivCounter,
phivCountersCountDataBlocksSent
PhivCounter,
phivCountersCountEthUsrBuffUnav
PhivCounter,
phivCountersCountMcastBytesRecd
PhivCounter,
phivCountersCountDataBlksRecd
PhivCounter,
phivCountersCountDataBlksSent
PhivCounter,
phivCountersCountMcastBlksRecd
PhivCounter,
phivCountersCountBlksSentDef
PhivCounter,
phivCountersCountBlksSentSingleCol
PhivCounter,
phivCountersCountBlksSentMultCol
PhivCounter,
phivCountersCountSendFailure
INTEGER,
phivCountersCountCollDetectFailure
INTEGER,
phivCountersCountReceiveFailure
INTEGER,
phivCountersCountUnrecFrameDest
INTEGER,
phivCountersCountDataOver
INTEGER,
phivCountersCountSysBuffUnav
INTEGER,
phivCountersCountUsrBuffUnav
INTEGER
}
phivCountersIndex OBJECT-TYPE
SYNTAX InterfaceIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The interface to which these counters apply. This is
the same interface as identified by the same value of
phivLineIndex. This value is the ifIndex."
::= { phivCountersCountEntry 1 }
phivCountersCountBytesRecd OBJECT-TYPE
SYNTAX PhivCounter (0..2147483647)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of bytes received over this link."
::= { phivCountersCountEntry 2 }
phivCountersCountBytesSent OBJECT-TYPE
SYNTAX PhivCounter (0..2147483647)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of bytes sent over this link."
::= { phivCountersCountEntry 3 }
phivCountersCountDataBlocksRecd OBJECT-TYPE
SYNTAX PhivCounter (0..2147483647)
ACCESS read-only
STATUS obsolete
DESCRIPTION
"Number of data blocks received over this link."
::= { phivCountersCountEntry 4 }
phivCountersCountDataBlocksSent OBJECT-TYPE
SYNTAX PhivCounter (0..2147483647)
ACCESS read-only
STATUS obsolete
DESCRIPTION
"Number of data blocks sent over this link."
::= { phivCountersCountEntry 5 }
phivCountersCountEthUsrBuffUnav OBJECT-TYPE
SYNTAX PhivCounter (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of user buffer unavailable errors over this
link."
::= { phivCountersCountEntry 6 }
phivCountersCountMcastBytesRecd OBJECT-TYPE
SYNTAX PhivCounter (0..2147483647)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of multicast bytes received over this link."
::= { phivCountersCountEntry 7 }
phivCountersCountDataBlksRecd OBJECT-TYPE
SYNTAX PhivCounter (0..2147483647)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of data blocks received over this link."
::= { phivCountersCountEntry 8 }
phivCountersCountDataBlksSent OBJECT-TYPE
SYNTAX PhivCounter (0..2147483647)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of data blocks sent over this link."
::= { phivCountersCountEntry 9 }
phivCountersCountMcastBlksRecd OBJECT-TYPE
SYNTAX PhivCounter (0..2147483647)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of multicast blocks received over this link."
::= { phivCountersCountEntry 10 }
phivCountersCountBlksSentDef OBJECT-TYPE
SYNTAX PhivCounter (0..2147483647)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of blocks sent, initially deferred over this
link."
::= { phivCountersCountEntry 11 }
phivCountersCountBlksSentSingleCol OBJECT-TYPE
SYNTAX PhivCounter (0..2147483647)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of blocks sent, single collision over this link."
::= { phivCountersCountEntry 12 }
phivCountersCountBlksSentMultCol OBJECT-TYPE
SYNTAX PhivCounter (0..2147483647)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of blocks sent, multiple collisions over this
link."
::= { phivCountersCountEntry 13 }
phivCountersCountSendFailure OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of send failures over this link."
::= { phivCountersCountEntry 14 }
phivCountersCountCollDetectFailure OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of collision detect check failures over this
link."
::= { phivCountersCountEntry 15 }
phivCountersCountReceiveFailure OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of receive failures over this link."
::= { phivCountersCountEntry 16 }
phivCountersCountUnrecFrameDest OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of unrecognized frame destinations over this
link."
::= { phivCountersCountEntry 17 }
phivCountersCountDataOver OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of data overruns over this link."
::= { phivCountersCountEntry 18 }
phivCountersCountSysBuffUnav OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of system buffer unavailables over this link."
::= { phivCountersCountEntry 19 }
phivCountersCountUsrBuffUnav OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of user buffer unavailables."
::= { phivCountersCountEntry 20 }
-- Adjacency Group
-- The implementation of the Adjacency Group is mandatory for all
-- conformant implementations of this memo.
-- The phivAdjTable has been made obsolete it has been replaced with
-- the phivAdjNodeTable.
phivAdjTable OBJECT-TYPE
SYNTAX SEQUENCE OF PhivAdjEntry
ACCESS not-accessible
STATUS obsolete
DESCRIPTION
"The Adjacency Table."
::= { adjacency 1 }
phivAdjEntry OBJECT-TYPE
SYNTAX PhivAdjEntry
ACCESS not-accessible
STATUS obsolete
DESCRIPTION
"There is one entry in the table for each adjacency."
INDEX { phivAdjCircuitIndex }
::= { phivAdjTable 1 }
PhivAdjEntry ::=
SEQUENCE {
phivAdjCircuitIndex
INTEGER,
phivAdjNodeAddr
PhivAddr,
phivAdjBlockSize
INTEGER,
phivAdjListenTimer
INTEGER (1..65535),
phivAdjCircuitEtherServPhysAddr
OCTET STRING,
phivAdjType
INTEGER,
phivAdjState
INTEGER,
phivAdjPriority
INTEGER,
phivAdjExecListenTimer
INTEGER (1..65535)
}
phivAdjCircuitIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS obsolete
DESCRIPTION
"A unique index value for each known circuit."
::= { phivAdjEntry 1 }
phivAdjNodeAddr OBJECT-TYPE
SYNTAX PhivAddr -- OCTET STRING (SIZE (2))
ACCESS read-only
STATUS obsolete
DESCRIPTION
"The address of the adjacent node."
::= { phivAdjEntry 2 }
phivAdjBlockSize OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS obsolete
DESCRIPTION
"This read-only parameter is the block size that was
negotiated with the adjacent Routing layer during Routing
initialization over a particular circuit. It includes the
routing header, but excludes the data link header. This
parameter is qualified by ADJACENT NODE."
::= { phivAdjEntry 3 }
phivAdjListenTimer OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS obsolete
DESCRIPTION
"This value determines the maximum number of seconds
allowed to elapse before Routing receives some message
(either a Hello message or a user message) from the
adjacent node on the circuit. It was agreed during
Routing initialization with the adjacent Routing layer.
This parameter is qualified by ADJACENT NODE."
::= { phivAdjEntry 4 }
phivAdjCircuitEtherServPhysAddr OBJECT-TYPE
SYNTAX OCTET STRING ( SIZE (6) )
ACCESS read-only
STATUS obsolete
DESCRIPTION
"This parameter indicates the Ethernet physical address
of an adjacent node that is being serviced on this
circuit. This parameter is a qualifier for SERVICE
SUBSTATE."
::= { phivAdjEntry 5 }
phivAdjType OBJECT-TYPE
SYNTAX INTEGER {
routing-III (1),
nonrouting-III (2),
area (3),
routing-IV (4),
nonrouting-IV (5)
}
ACCESS read-only
STATUS obsolete
DESCRIPTION
"This parameter indicates the type of adjacency.
For adjacent nodes, this is a read-only parameter that
indicates the type of the reachable adjacent node.
NOTE: The routing-III and nonrouting-III values are
incremented by one compared to the standard DECnet
values in order to maintain compliance with RFC 1155)"
::= { phivAdjEntry 6 }
phivAdjState OBJECT-TYPE
SYNTAX INTEGER {
initializing (1), -- Ethernet one-way
up (2), -- Ethernet two-way
run (3), -- The eight DDCMP/X.25 states
circuit-rejected (4),
data-link-start (5),
routing-layer-initialize (6),
routing-layer-verify (7),
routing-layer-complete (8),
off (9),
halt (10)
}
ACCESS read-only
STATUS obsolete
DESCRIPTION
"This value indicates the state of a router adjacency.
On adjacencies over a circuit of type
(phivCircuitCommonType) Ethernet, CI, or FDDI, with an
adjacent node of type (phivAdjType) ROUTING IV or AREA,
this variable is the state of the Ethernet
Initialization Layer for this adjacency, and can have
values INITIALIZING or UP. (See Section 9.1.1 of
DECnet Phase IV Routing Layer Functional Specification.)
On adjacencies over a circuit of type
(phivCircuitCommonType) Ethernet, CI, or FDDI, with an
adjacent node of type (phivAdjType) NONROUTING IV,
this variable will always take on the value UP.
On adjacencies over a circuit of type
(phivCircuitCommonType) DDCMP POINT, DDCMP CONTROL,
DDCMP TRIBUTARY, DDCMP DMC, or X.25, this variable is
the state of the Routing Layer Initialization Circuit
State. (See section 7.3, ibid.) It can have values
between RUN and HALT.
On adjacencies over a circuit of type
(phivCircuitCommonType) OTHER, this variable may be
used in a manner consistent with the Initialization
Layer used on that circuit."
::= { phivAdjEntry 7 }
phivAdjPriority OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS obsolete
DESCRIPTION
"Priority assigned by the adjacent node for this
circuit."
::= { phivAdjEntry 8 }
phivAdjExecListenTimer OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS obsolete
DESCRIPTION
"This read-only value determines the maximum number of
seconds allowed to elapse before Routing receives some
message (either a Hello message or a user message) from
the adjacent node on the circuit. It was agreed during
Routing initialization with the adjacent Routing layer."
::= { phivAdjEntry 9 }
-- New Adjacency Table this replaces the phivAdjTable.
phivAdjNodeTable OBJECT-TYPE
SYNTAX SEQUENCE OF PhivAdjNodeEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The Adjacent Node Table."
::= { adjacency 2 }
phivAdjNodeEntry OBJECT-TYPE
SYNTAX PhivAdjNodeEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"There is one entry in the table for each adjacency."
INDEX { phivAdjNodeCircuitIndex, phivAdjAddr }
::= { phivAdjNodeTable 1 }
PhivAdjNodeEntry ::=
SEQUENCE {
phivAdjNodeCircuitIndex
INTEGER,
phivAdjAddr
PhivAddr,
phivAdjNodeBlockSize
INTEGER,
phivAdjNodeListenTimer
INTEGER,
phivAdjNodeCircuitEtherServPhysAddr
OCTET STRING,
phivAdjNodeType
INTEGER,
phivAdjNodeState
INTEGER,
phivAdjNodePriority
INTEGER
}
phivAdjNodeCircuitIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A unique index value for each known circuit. This
value is the same as phivCircuitIndex and identifies the
circuit over which the adjacency is realized."
::= { phivAdjNodeEntry 1 }
phivAdjAddr OBJECT-TYPE
SYNTAX PhivAddr -- OCTET STRING (SIZE (2))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The address of the adjacent node."
::= { phivAdjNodeEntry 2 }
phivAdjNodeBlockSize OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This read-only parameter is the block size that was
negotiated with the adjacent Routing layer during Routing
initialization over a particular circuit. It includes the
routing header, but excludes the data link header. This
parameter is qualified by ADJACENT NODE."
::= { phivAdjNodeEntry 3 }
phivAdjNodeListenTimer OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value determines the maximum number of seconds
allowed to elapse before Routing receives some message
(either a Hello message or a user message) from the
adjacent node on the circuit. It was agreed during
Routing initialization with the adjacent Routing layer.
This parameter is qualified by ADJACENT NODE."
::= { phivAdjNodeEntry 4 }
phivAdjNodeCircuitEtherServPhysAddr OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (6))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This parameter indicates the Ethernet physical address
of an adjacent node that is being serviced on this
circuit. This parameter is a qualifier for SERVICE
SUBSTATE."
::= { phivAdjNodeEntry 5 }
phivAdjNodeType OBJECT-TYPE
SYNTAX INTEGER {
routing-III (1),
nonrouting-III (2),
area (3),
routing-IV (4),
nonrouting-IV (5)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This parameter indicates the type of adjacency.
For adjacent nodes, this is a read-only parameter that
indicates the type of the reachable adjacent node.
NOTE: The routing-III and nonrouting-III values are
incremented by one compared to the standard DECnet
values in order to maintain compliance with RFC 1155)"
::= { phivAdjNodeEntry 6 }
phivAdjNodeState OBJECT-TYPE
SYNTAX INTEGER {
initializing (1), -- Ethernet one-way
up (2), -- Ethernet two-way
run (3), -- The eight DDCMP/X.25 states
circuit-rejected (4),
data-link-start (5),
routing-layer-initialize (6),
routing-layer-verify (7),
routing-layer-complete (8),
off (9),
halt (10)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the state of a router adjacency.
On adjacencies over a circuit of type
(phivCircuitCommonType) Ethernet, CI, or FDDI, with an
adjacent node of type (phivAdjNodeType) ROUTING IV or AREA,
this variable is the state of the Ethernet
Initialization Layer for this adjacency, and can have
values INITIALIZING or UP. (See Section 9.1.1 of
DECnet Phase IV Routing Layer Functional Specification.)
On adjacencies over a circuit of type
(phivCircuitCommonType) Ethernet, CI, or FDDI, with an
adjacent node of type (phivAdjNodeType) NONROUTING IV,
this variable will always take on the value UP.
On adjacencies over a circuit of type
(phivCircuitCommonType) DDCMP POINT, DDCMP CONTROL,
DDCMP TRIBUTARY, DDCMP DMC, or X.25, this variable is
the state of the Routing Layer Initialization Circuit
State. (See section 7.3, ibid.) It can have values
between RUN and HALT.
On adjacencies over a circuit of type
(phivCircuitCommonType) OTHER, this variable may be
used in a manner consistent with the Initialization
Layer used on that circuit."
::= { phivAdjNodeEntry 7 }
phivAdjNodePriority OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Priority assigned by the adjacent node for this
circuit."
::= { phivAdjNodeEntry 8 }
-- Line Group
-- The implementation of the Line Group is mandatory for all
-- conformant implementations of this memo.
phivLineTable OBJECT-TYPE
SYNTAX SEQUENCE OF PhivLineEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The Line Table."
::= { line 1 }
phivLineEntry OBJECT-TYPE
SYNTAX PhivLineEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"There is one entry in the table for each line."
INDEX { phivLineIndex }
::= { phivLineTable 1 }
PhivLineEntry ::=
SEQUENCE {
phivLineIndex
InterfaceIndex,
phivLineName
DisplayString,
phivLineState
INTEGER,
phivLineSubstate
INTEGER,
phivLineService
INTEGER,
phivLineDevice
DisplayString,
phivLineReceiveBuffs
INTEGER,
phivLineProtocol
INTEGER,
phivLineServiceTimer
INTEGER,
phivLineMaxBlock
INTEGER
}
phivLineIndex OBJECT-TYPE
SYNTAX InterfaceIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The line on which this entry's equivalence is effective.
This is the same as the ifIndex."
::= { phivLineEntry 1 }
phivLineName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The name of the line on this row of the table."
::= { phivLineEntry 2 }
phivLineState OBJECT-TYPE
SYNTAX INTEGER {
on (1),
off (2),
service (3),
cleared (4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value represents Network Management operational
state.
NOTE that these values are incremented by one compared to
the standard DECnet values."
::= { phivLineEntry 3 }
phivLineSubstate OBJECT-TYPE
SYNTAX INTEGER {
starting (1),
reflecting (2),
looping (3),
loading (4),
dumping (5),
triggering (6),
auto-service (7),
auto-loading (8),
auto-dumping (9),
auto-triggering (10),
synchronizing (11),
failed (12),
running (13)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value represents the line's read-only Network
Management substate.
NOTE that these values are incremented by one compared to
the standard DECnet values."
::= { phivLineEntry 4 }
phivLineService OBJECT-TYPE
SYNTAX INTEGER {
starting (1),
reflecting (2),
looping (3),
other (4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value represents the line's read-only Network
Management service.
NOTE that these values are incremented by one compared to
the standard DECnet values and OTHER is a new addition."
::= { phivLineEntry 5 }
phivLineDevice OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value represents the Physical Link device to be
used on the line."
::= { phivLineEntry 6 }
phivLineReceiveBuffs OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value represents the number of receive buffers
reserved for the line. It is a decimal number in
the range 0-65535. 0 is supported for those vendors
that do not reserve buffers on a per line basis and
use a pool of buffers that can be used by any line."
::= { phivLineEntry 7 }
phivLineProtocol OBJECT-TYPE
SYNTAX INTEGER {
ddcmp-point (1),
ddcmp-control (2),
ddcmp-tributary (3),
reserved (4),
ddcmp-dmc (5),
olapb (6),
ethernet (7),
ci (8),
qp2 (9),
other (14),
fddi (15)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value represents the protocol used on the line
device. Note that these values are incremented by
one compared to the standard DECnet values."
::= { phivLineEntry 8 }
phivLineServiceTimer OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value represents the amount of time in
milliseconds allowed to elapse before a Data Link
receive request completes while doing service
operations."
::= { phivLineEntry 9 }
phivLineMaxBlock OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value represents the Data Link maximum block
size on the line."
::= { phivLineEntry 10 }
-- Non Broadcast Line Group
-- The implementation of the Non Broadcast Line Group is optional.
-- A system can be said to implement this group if and only if
-- all objects in this group are implemented.
phivNonBroadcastTable OBJECT-TYPE
SYNTAX SEQUENCE OF PhivNonBroadcastEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The Non Broadcast Table."
::= { nonBroadcastLine 1 }
phivNonBroadcastEntry OBJECT-TYPE
SYNTAX PhivNonBroadcastEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"There is one entry in the table for each
Non Broadcast line."
INDEX { phivNonBroadcastIndex }
::= { phivNonBroadcastTable 1 }
PhivNonBroadcastEntry ::=
SEQUENCE {
phivNonBroadcastIndex
InterfaceIndex,
phivNonBroadcastController
INTEGER,
phivNonBroadcastDuplex
INTEGER,
phivNonBroadcastClock
INTEGER,
phivNonBroadcastRetransmitTimer
INTEGER
}
phivNonBroadcastIndex OBJECT-TYPE
SYNTAX InterfaceIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Non Broadcast line on which this entry's
equivalence is effective. This is the same value
as the ifIndex."
::= { phivNonBroadcastEntry 1 }
phivNonBroadcastController OBJECT-TYPE
SYNTAX INTEGER {
normal (1),
loopback (2),
other (3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value represents the Physical Link hardware
controller mode for the line device. The values
for controller-mode are:
NORMAL For normal controller operating mode.
LOOPBACK For software controllable loopback of the
controller. On those devices that can support this
mode, it causes all transmitted messages to be looped
back from within the controller itself. This is
accomplished without any manual intervention other
than the setting of this parameter value.
OTHER indicates function is not supported
Note that these values are incremented by one compared to
the standard DECnet values."
::= { phivNonBroadcastEntry 2 }
phivNonBroadcastDuplex OBJECT-TYPE
SYNTAX INTEGER {
full (1),
half (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value represents the Physical Link hardware
duplex mode of the line device. The possible modes
are:
FULL Full-duplex
HALF Half-duplex
Note that these values are incremented by one compared to
the standard DECnet values."
::= { phivNonBroadcastEntry 3 }
phivNonBroadcastClock OBJECT-TYPE
SYNTAX INTEGER {
external (1),
internal (2),
other (3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value represents the Physical Link hardware clock
mode for the line device. The values for clock-mode are:
INTERNAL For software controllable loopback use of
the clock. On those devices that can support this
mode, it causes the device to supply a clock signal
such that a transmitted messages can be looped
back from outside the device. This may require manual
intervention other than the setting of this parameter
value. For example, the operator may have to connect
a loopback plug in place of the normal line.
EXTERNAL For normal clock operating mode, where the
clock signal is supplied externally to the controller.
Note that these values are incremented by one compared to
the standard DECnet values."
::= { phivNonBroadcastEntry 4 }
phivNonBroadcastRetransmitTimer OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value represents number of milliseconds before
the Data Link retransmits a block on the line. On
half-duplex lines, this parameter is the select timer."
DEFVAL { 3000 }
::= { phivNonBroadcastEntry 5 }
-- Area Parameters Group
-- The implementation of the Area Parameters Group is mandatory
-- for all systems which implement level 2 routing.
phivAreaTable OBJECT-TYPE
SYNTAX SEQUENCE OF PhivAreaEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Table of information kept on all areas known to
this unit."
::= { area 1 }
phivAreaEntry OBJECT-TYPE
SYNTAX PhivAreaEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The area routing information."
INDEX { phivAreaNum }
::= { phivAreaTable 1 }
PhivAreaEntry ::=
SEQUENCE {
phivAreaNum
INTEGER,
phivAreaState
INTEGER,
phivAreaCost
Gauge,
phivAreaHops
INTEGER,
phivAreaNextNode
PhivAddr,
phivAreaCircuitIndex
INTEGER
}
phivAreaNum OBJECT-TYPE
SYNTAX INTEGER (0..64)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the area number of this entry."
::= { phivAreaEntry 1 }
phivAreaState OBJECT-TYPE
SYNTAX INTEGER {
reachable (4),
unreachable (5)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the state of the area"
::= { phivAreaEntry 2 }
phivAreaCost OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total cost over the current path to the
destination area. Cost is a value associated with
using a circuit. Routing routes messages (data)
along the path between 2 areas with the smallest
cost."
::= { phivAreaEntry 3 }
phivAreaHops OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of hops to a destination area. A hop is
the routing value representing the logical distance
between two areas in network."
::= { phivAreaEntry 4 }
phivAreaNextNode OBJECT-TYPE
SYNTAX PhivAddr -- OCTET STRING (SIZE (2))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The next node on the circuit used to get to the
area under scrutiny."
::= { phivAreaEntry 5 }
phivAreaCircuitIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A unique index value for each known circuit."
::= { phivAreaEntry 6 }
-- Additional Area Parameters
phivAreaMaxCost OBJECT-TYPE
SYNTAX INTEGER (1..1022)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This value represents the maximum total path cost
allowed from the executor to any other level 2 routing
node. The AREA MAXIMUM COST number is decimal in the
range 1-1022. This parameter is only applicable if
the executor node is of type AREA."
::= { area 2 }
phivAreaMaxHops OBJECT-TYPE
SYNTAX INTEGER (1..30)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This value represents the maximum number of routing hops
allowable from the executor to any other level 2
routing node. This parameter is only applicable if the
executor node is of type AREA."
::= { area 3 }
phivRouteMaxArea OBJECT-TYPE
SYNTAX INTEGER (1..63)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This value represents the largest area number and,
therefore, number of areas that can be known about
by the executor node's Routing. This parameter is only
applicable if the executor node is of type AREA."
::= { area 4 }
END