pandorafms/pandora_console/attachment/mibs/CISCO-ENVMON-MIB.mib

939 lines
36 KiB
Plaintext
Raw Normal View History

2020-02-28 11:32:33 +01:00
-- *****************************************************************
-- CISCO-ENVMON-MIB.my: CISCO Environmental Monitor MIB file
--
-- November 1994 Sandra C. Durham/Jeffrey T. Johnson
--
-- Copyright (c) 1994-2003, 2004 by cisco Systems, Inc.
-- All rights reserved.
--
-- *****************************************************************
--
CISCO-ENVMON-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY,
OBJECT-TYPE,
NOTIFICATION-TYPE,
Gauge32,
Integer32
FROM SNMPv2-SMI
TEXTUAL-CONVENTION,
DisplayString,
TruthValue
FROM SNMPv2-TC
MODULE-COMPLIANCE,
OBJECT-GROUP,
NOTIFICATION-GROUP
FROM SNMPv2-CONF
ciscoMgmt
FROM CISCO-SMI;
ciscoEnvMonMIB MODULE-IDENTITY
LAST-UPDATED "200312010000Z"
ORGANIZATION "Cisco Systems, Inc."
CONTACT-INFO
" Cisco Systems
Customer Service
Postal: 170 W Tasman Drive
San Jose, CA 95134
USA
Tel: +1 800 553-NETS
E-mail: cs-snmp@cisco.com"
DESCRIPTION
"The MIB module to describe the status of the Environmental
Monitor on those devices which support one."
REVISION "200312010000Z"
DESCRIPTION
"Added c37xx (13) and other (14) as values for
ciscoEnvMonPresent"
REVISION "200311250000Z"
DESCRIPTION
"Added ciscoEnvMonMIBMiscNotifGroup."
REVISION "200210150000Z"
DESCRIPTION
"Added c7600(12) as values for ciscoEnvMonPresent"
REVISION "200207170000Z"
DESCRIPTION
"Added optional groups ciscoEnvMonEnableStatChangeGroup
and ciscoEnvMonStatChangeNotifGroup."
REVISION "200202040000Z"
DESCRIPTION
"Added osr7600(11) as values
for ciscoEnvMonPresent"
REVISION "200108300000Z"
DESCRIPTION
"Added c10000(10) as values for ciscoEnvMonPresent"
REVISION "200108160000Z"
DESCRIPTION
"Added cat4000(9) as values for ciscoEnvMonPresent"
REVISION "200105070000Z"
DESCRIPTION
"Added cat6000(7),ubr7200(8)
as values for ciscoEnvMonPresent"
REVISION "200001310000Z"
DESCRIPTION
"Add notFunctioning to CiscoEnvMonState.
"
REVISION "9810220000Z"
DESCRIPTION
"Renamed enumerated value internalRPS(5) as
internalRedundant(5) and added description for
ciscoEnvMonSupplySource enumerated values.
"
REVISION "9808050000Z"
DESCRIPTION
"Add enumerated value internalRPS(5) to
ciscoEnvMonSupplySource.
"
REVISION "9611120000Z"
DESCRIPTION
"Add monitoring support for c3600 series router"
REVISION "9508150000Z"
DESCRIPTION
"Specify a correct (non-negative) range for several
index objects."
REVISION "9503130000Z"
DESCRIPTION
"Miscellaneous changes including monitoring support
for c7000 series redundant power supplies."
::= { ciscoMgmt 13 }
CiscoEnvMonState ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Represents the state of a device being monitored.
Valid values are:
normal(1): the environment is good, such as low
temperature.
warning(2): the environment is bad, such as temperature
above normal operation range but not too
high.
critical(3): the environment is very bad, such as
temperature much higher than normal
operation limit.
shutdown(4): the environment is the worst, the system
should be shutdown immediately.
notPresent(5): the environmental monitor is not present,
such as temperature sensors do not exist.
notFunctioning(6): the environmental monitor does not
function properly, such as a temperature
sensor generates a abnormal data like
1000 C.
"
SYNTAX INTEGER {
normal(1),
warning(2),
critical(3),
shutdown(4),
notPresent(5),
notFunctioning(6)
}
CiscoSignedGauge ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Represents the current value of an entity, as a signed
integer."
SYNTAX Integer32
ciscoEnvMonObjects OBJECT IDENTIFIER ::= { ciscoEnvMonMIB 1 }
ciscoEnvMonPresent OBJECT-TYPE
SYNTAX INTEGER {
oldAgs (1),
ags (2),
c7000 (3),
ci (4),
cAccessMon (6),
cat6000 (7),
ubr7200 (8),
cat4000 (9),
c10000 (10),
osr7600(11),
c7600 (12),
c37xx (13),
other (14)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of environmental monitor located in the chassis.
An oldAgs environmental monitor card is identical to an ags
environmental card except that it is not capable of supplying
data, and hence no instance of the remaining objects in this
MIB will be returned in response to an SNMP query. Note that
only a firmware upgrade is required to convert an oldAgs into
an ags card."
::= { ciscoEnvMonObjects 1 }
ciscoEnvMonVoltageStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF CiscoEnvMonVoltageStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table of voltage status maintained by the environmental
monitor."
::= { ciscoEnvMonObjects 2 }
ciscoEnvMonVoltageStatusEntry OBJECT-TYPE
SYNTAX CiscoEnvMonVoltageStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the voltage status table, representing the status
of the associated testpoint maintained by the environmental
monitor."
INDEX { ciscoEnvMonVoltageStatusIndex }
::= { ciscoEnvMonVoltageStatusTable 1 }
CiscoEnvMonVoltageStatusEntry ::=
SEQUENCE {
ciscoEnvMonVoltageStatusIndex Integer32,
ciscoEnvMonVoltageStatusDescr DisplayString,
ciscoEnvMonVoltageStatusValue CiscoSignedGauge,
ciscoEnvMonVoltageThresholdLow Integer32,
ciscoEnvMonVoltageThresholdHigh Integer32,
ciscoEnvMonVoltageLastShutdown Integer32,
ciscoEnvMonVoltageState CiscoEnvMonState
}
ciscoEnvMonVoltageStatusIndex OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Unique index for the testpoint being instrumented.
This index is for SNMP purposes only, and has no
intrinsic meaning."
::= { ciscoEnvMonVoltageStatusEntry 1 }
ciscoEnvMonVoltageStatusDescr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Textual description of the testpoint being instrumented.
This description is a short textual label, suitable as a
human-sensible identification for the rest of the
information in the entry."
::= { ciscoEnvMonVoltageStatusEntry 2 }
ciscoEnvMonVoltageStatusValue OBJECT-TYPE
SYNTAX CiscoSignedGauge
UNITS "millivolts"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current measurement of the testpoint being instrumented."
::= { ciscoEnvMonVoltageStatusEntry 3 }
ciscoEnvMonVoltageThresholdLow OBJECT-TYPE
SYNTAX Integer32
UNITS "millivolts"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The lowest value that the associated instance of the object
ciscoEnvMonVoltageStatusValue may obtain before an emergency
shutdown of the managed device is initiated."
::= { ciscoEnvMonVoltageStatusEntry 4 }
ciscoEnvMonVoltageThresholdHigh OBJECT-TYPE
SYNTAX Integer32
UNITS "millivolts"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The highest value that the associated instance of the object
ciscoEnvMonVoltageStatusValue may obtain before an emergency
shutdown of the managed device is initiated."
::= { ciscoEnvMonVoltageStatusEntry 5 }
ciscoEnvMonVoltageLastShutdown OBJECT-TYPE
SYNTAX Integer32
UNITS "millivolts"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of the associated instance of the object
ciscoEnvMonVoltageStatusValue at the time an emergency
shutdown of the managed device was last initiated. This
value is stored in non-volatile RAM and hence is able to
survive the shutdown."
::= { ciscoEnvMonVoltageStatusEntry 6 }
ciscoEnvMonVoltageState OBJECT-TYPE
SYNTAX CiscoEnvMonState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current state of the testpoint being instrumented."
::= { ciscoEnvMonVoltageStatusEntry 7 }
ciscoEnvMonTemperatureStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF CiscoEnvMonTemperatureStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table of ambient temperature status maintained by the
environmental monitor."
::= { ciscoEnvMonObjects 3 }
ciscoEnvMonTemperatureStatusEntry OBJECT-TYPE
SYNTAX CiscoEnvMonTemperatureStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the ambient temperature status table, representing
the status of the associated testpoint maintained by the
environmental monitor."
INDEX { ciscoEnvMonTemperatureStatusIndex }
::= { ciscoEnvMonTemperatureStatusTable 1 }
CiscoEnvMonTemperatureStatusEntry ::=
SEQUENCE {
ciscoEnvMonTemperatureStatusIndex Integer32,
ciscoEnvMonTemperatureStatusDescr DisplayString,
ciscoEnvMonTemperatureStatusValue Gauge32,
ciscoEnvMonTemperatureThreshold Integer32,
ciscoEnvMonTemperatureLastShutdown Integer32,
ciscoEnvMonTemperatureState CiscoEnvMonState
}
ciscoEnvMonTemperatureStatusIndex OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Unique index for the testpoint being instrumented.
This index is for SNMP purposes only, and has no
intrinsic meaning."
::= { ciscoEnvMonTemperatureStatusEntry 1 }
ciscoEnvMonTemperatureStatusDescr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Textual description of the testpoint being instrumented.
This description is a short textual label, suitable as a
human-sensible identification for the rest of the
information in the entry."
::= { ciscoEnvMonTemperatureStatusEntry 2 }
ciscoEnvMonTemperatureStatusValue OBJECT-TYPE
SYNTAX Gauge32
UNITS "degrees Celsius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current measurement of the testpoint being instrumented."
::= { ciscoEnvMonTemperatureStatusEntry 3 }
ciscoEnvMonTemperatureThreshold OBJECT-TYPE
SYNTAX Integer32
UNITS "degrees Celsius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The highest value that the associated instance of the
object ciscoEnvMonTemperatureStatusValue may obtain
before an emergency shutdown of the managed device is
initiated."
::= { ciscoEnvMonTemperatureStatusEntry 4 }
ciscoEnvMonTemperatureLastShutdown OBJECT-TYPE
SYNTAX Integer32
UNITS "degrees Celsius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of the associated instance of the object
ciscoEnvMonTemperatureStatusValue at the time an emergency
shutdown of the managed device was last initiated. This
value is stored in non-volatile RAM and hence is able to
survive the shutdown."
::= { ciscoEnvMonTemperatureStatusEntry 5 }
ciscoEnvMonTemperatureState OBJECT-TYPE
SYNTAX CiscoEnvMonState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current state of the testpoint being instrumented."
::= { ciscoEnvMonTemperatureStatusEntry 6 }
ciscoEnvMonFanStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF CiscoEnvMonFanStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table of fan status maintained by the environmental
monitor."
::= { ciscoEnvMonObjects 4 }
ciscoEnvMonFanStatusEntry OBJECT-TYPE
SYNTAX CiscoEnvMonFanStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the fan status table, representing the status of
the associated fan maintained by the environmental monitor."
INDEX { ciscoEnvMonFanStatusIndex }
::= { ciscoEnvMonFanStatusTable 1 }
CiscoEnvMonFanStatusEntry ::=
SEQUENCE {
ciscoEnvMonFanStatusIndex Integer32,
ciscoEnvMonFanStatusDescr DisplayString,
ciscoEnvMonFanState CiscoEnvMonState
}
ciscoEnvMonFanStatusIndex OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Unique index for the fan being instrumented.
This index is for SNMP purposes only, and has no
intrinsic meaning."
::= { ciscoEnvMonFanStatusEntry 1 }
ciscoEnvMonFanStatusDescr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Textual description of the fan being instrumented.
This description is a short textual label, suitable as a
human-sensible identification for the rest of the
information in the entry."
::= { ciscoEnvMonFanStatusEntry 2 }
ciscoEnvMonFanState OBJECT-TYPE
SYNTAX CiscoEnvMonState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current state of the fan being instrumented."
::= { ciscoEnvMonFanStatusEntry 3 }
ciscoEnvMonSupplyStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF CiscoEnvMonSupplyStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table of power supply status maintained by the
environmental monitor card."
::= { ciscoEnvMonObjects 5 }
ciscoEnvMonSupplyStatusEntry OBJECT-TYPE
SYNTAX CiscoEnvMonSupplyStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the power supply status table, representing the
status of the associated power supply maintained by the
environmental monitor card."
INDEX { ciscoEnvMonSupplyStatusIndex }
::= { ciscoEnvMonSupplyStatusTable 1 }
CiscoEnvMonSupplyStatusEntry ::=
SEQUENCE {
ciscoEnvMonSupplyStatusIndex Integer32,
ciscoEnvMonSupplyStatusDescr DisplayString,
ciscoEnvMonSupplyState CiscoEnvMonState,
ciscoEnvMonSupplySource INTEGER
}
ciscoEnvMonSupplyStatusIndex OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Unique index for the power supply being instrumented.
This index is for SNMP purposes only, and has no
intrinsic meaning."
::= { ciscoEnvMonSupplyStatusEntry 1 }
ciscoEnvMonSupplyStatusDescr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Textual description of the power supply being instrumented.
This description is a short textual label, suitable as a
human-sensible identification for the rest of the
information in the entry."
::= { ciscoEnvMonSupplyStatusEntry 2 }
ciscoEnvMonSupplyState OBJECT-TYPE
SYNTAX CiscoEnvMonState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current state of the power supply being instrumented."
::= { ciscoEnvMonSupplyStatusEntry 3 }
ciscoEnvMonSupplySource OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
ac(2),
dc(3),
externalPowerSupply(4),
internalRedundant(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The power supply source.
unknown - Power supply source unknown
ac - AC power supply
dc - DC power supply
externalPowerSupply - External power supply
internalRedundant - Internal redundant power supply
"
::= { ciscoEnvMonSupplyStatusEntry 4 }
ciscoEnvMonAlarmContacts OBJECT-TYPE
SYNTAX BITS {
minorVisual(0),
majorVisual(1),
criticalVisual(2),
minorAudible(3),
majorAudible(4),
criticalAudible(5),
input(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Each bit is set to reflect the respective
alarm being set. The bit will be cleared
when the respective alarm is cleared."
::= { ciscoEnvMonObjects 6 }
ciscoEnvMonMIBNotificationEnables OBJECT IDENTIFIER ::= { ciscoEnvMonMIB 2 }
ciscoEnvMonEnableShutdownNotification OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable indicates whether the system
produces the ciscoEnvMonShutdownNotification. A false
value will prevent shutdown notifications
from being generated by this system."
DEFVAL { false }
::= { ciscoEnvMonMIBNotificationEnables 1 }
ciscoEnvMonEnableVoltageNotification OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"This variable indicates whether the system
produces the ciscoEnvMonVoltageNotification. A false
value will prevent voltage notifications from being
generated by this system. This object is deprecated
in favour of ciscoEnvMonEnableStatChangeNotif."
DEFVAL { false }
::= { ciscoEnvMonMIBNotificationEnables 2 }
ciscoEnvMonEnableTemperatureNotification OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"This variable indicates whether the system
produces the ciscoEnvMonTemperatureNotification.
A false value prevents temperature notifications
from being sent by this entity. This object is
deprecated in favour of
ciscoEnvMonEnableStatChangeNotif."
DEFVAL { false }
::= { ciscoEnvMonMIBNotificationEnables 3 }
ciscoEnvMonEnableFanNotification OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"This variable indicates whether the system
produces the ciscoEnvMonFanNotification.
A false value prevents fan notifications
from being sent by this entity. This object is
deprecated in favour of
ciscoEnvMonEnableStatChangeNotif."
DEFVAL { false }
::= { ciscoEnvMonMIBNotificationEnables 4 }
ciscoEnvMonEnableRedundantSupplyNotification OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"This variable indicates whether the system
produces the ciscoEnvMonRedundantSupplyNotification.
A false value prevents redundant supply notifications
from being generated by this system. This object is
deprecated in favour of
ciscoEnvMonEnableStatChangeNotif."
DEFVAL { false }
::= { ciscoEnvMonMIBNotificationEnables 5 }
ciscoEnvMonEnableStatChangeNotif OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable indicates whether the system
produces the ciscoEnvMonVoltStatusChangeNotif,
ciscoEnvMonTempStatusChangeNotif,
ciscoEnvMonFanStatusChangeNotif and
ciscoEnvMonSuppStatusChangeNotif. A false value will
prevent these notifications from being generated by
this system."
DEFVAL { false }
::= { ciscoEnvMonMIBNotificationEnables 6 }
-- the following two OBJECT IDENTIFIERS are used to define SNMPv2 Notifications
-- that are backward compatible with SNMPv1 Traps.
ciscoEnvMonMIBNotificationPrefix OBJECT IDENTIFIER ::= { ciscoEnvMonMIB 3 }
ciscoEnvMonMIBNotifications OBJECT IDENTIFIER ::= { ciscoEnvMonMIBNotificationPrefix 0 }
ciscoEnvMonShutdownNotification NOTIFICATION-TYPE
-- no OBJECTS
STATUS current
DESCRIPTION
"A ciscoEnvMonShutdownNotification is sent if the environmental
monitor detects a testpoint reaching a critical state
and is about to initiate a shutdown. This notification
contains no objects so that it may be encoded and sent in the
shortest amount of time possible. Even so, management
applications should not rely on receiving such a notification
as it may not be sent before the shutdown completes."
::= { ciscoEnvMonMIBNotifications 1 }
ciscoEnvMonVoltageNotification NOTIFICATION-TYPE
OBJECTS {
ciscoEnvMonVoltageStatusDescr,
ciscoEnvMonVoltageStatusValue,
ciscoEnvMonVoltageState
}
STATUS deprecated
DESCRIPTION
"A ciscoEnvMonVoltageNotification is sent if the voltage
measured at a given testpoint is outside the normal range
for the testpoint (i.e. is at the warning, critical, or
shutdown stage). Since such a notification is usually
generated before the shutdown state is reached, it can
convey more data and has a better chance of being sent
than does the ciscoEnvMonShutdownNotification.
This notification is deprecated in favour of
ciscoEnvMonVoltStatusChangeNotif."
::= { ciscoEnvMonMIBNotifications 2 }
ciscoEnvMonTemperatureNotification NOTIFICATION-TYPE
OBJECTS {
ciscoEnvMonTemperatureStatusDescr,
ciscoEnvMonTemperatureStatusValue,
ciscoEnvMonTemperatureState
}
STATUS deprecated
DESCRIPTION
"A ciscoEnvMonTemperatureNotification is sent if the
temperature measured at a given testpoint is outside
the normal range for the testpoint (i.e. is at the warning,
critical, or shutdown stage). Since such a Notification
is usually generated before the shutdown state is reached,
it can convey more data and has a better chance of being
sent than does the ciscoEnvMonShutdownNotification.
This notification is deprecated in favour of
ciscoEnvMonTempStatusChangeNotif."
::= { ciscoEnvMonMIBNotifications 3 }
ciscoEnvMonFanNotification NOTIFICATION-TYPE
OBJECTS {
ciscoEnvMonFanStatusDescr,
ciscoEnvMonFanState
}
STATUS deprecated
DESCRIPTION
"A ciscoEnvMonFanNotification is sent if any one of
the fans in the fan array (where extant) fails.
Since such a notification is usually generated before
the shutdown state is reached, it can convey more
data and has a better chance of being sent
than does the ciscoEnvMonShutdownNotification.
This notification is deprecated in favour of
ciscoEnvMonFanStatusChangeNotif."
::= { ciscoEnvMonMIBNotifications 4 }
ciscoEnvMonRedundantSupplyNotification NOTIFICATION-TYPE
OBJECTS {
ciscoEnvMonSupplyStatusDescr,
ciscoEnvMonSupplyState
}
STATUS deprecated
DESCRIPTION
"A ciscoEnvMonRedundantSupplyNotification is sent if
the redundant power supply (where extant) fails.
Since such a notification is usually generated before
the shutdown state is reached, it can convey more
data and has a better chance of being sent
than does the ciscoEnvMonShutdownNotification.
This notification is deprecated in favour of
ciscoEnvMonSuppStatusChangeNotif."
::= { ciscoEnvMonMIBNotifications 5 }
ciscoEnvMonVoltStatusChangeNotif NOTIFICATION-TYPE
OBJECTS {
ciscoEnvMonVoltageStatusDescr,
ciscoEnvMonVoltageStatusValue,
ciscoEnvMonVoltageState
}
STATUS current
DESCRIPTION
"A ciscoEnvMonVoltStatusChangeNotif is sent if there is
change in the state of a device being monitored
by ciscoEnvMonVoltageState."
::= { ciscoEnvMonMIBNotifications 6 }
ciscoEnvMonTempStatusChangeNotif NOTIFICATION-TYPE
OBJECTS {
ciscoEnvMonTemperatureStatusDescr,
ciscoEnvMonTemperatureStatusValue,
ciscoEnvMonTemperatureState
}
STATUS current
DESCRIPTION
"A ciscoEnvMonTempStatusChangeNotif is sent if there
is change in the state of a device being monitored
by ciscoEnvMonTemperatureState."
::= { ciscoEnvMonMIBNotifications 7 }
ciscoEnvMonFanStatusChangeNotif NOTIFICATION-TYPE
OBJECTS {
ciscoEnvMonFanStatusDescr,
ciscoEnvMonFanState
}
STATUS current
DESCRIPTION
"A ciscoEnvMonFanStatusChangeNotif is sent if there
is change in the state of a device being monitored
by ciscoEnvMonFanState."
::= { ciscoEnvMonMIBNotifications 8 }
ciscoEnvMonSuppStatusChangeNotif NOTIFICATION-TYPE
OBJECTS {
ciscoEnvMonSupplyStatusDescr,
ciscoEnvMonSupplyState
}
STATUS current
DESCRIPTION
"A ciscoEnvMonSupplyStatChangeNotif is sent if there
is change in the state of a device being monitored
by ciscoEnvMonSupplyState."
::= { ciscoEnvMonMIBNotifications 9 }
-- conformance information
ciscoEnvMonMIBConformance OBJECT IDENTIFIER ::= { ciscoEnvMonMIB 4 }
ciscoEnvMonMIBCompliances OBJECT IDENTIFIER ::= { ciscoEnvMonMIBConformance 1 }
ciscoEnvMonMIBGroups OBJECT IDENTIFIER ::= { ciscoEnvMonMIBConformance 2 }
-- compliance statements
ciscoEnvMonMIBCompliance MODULE-COMPLIANCE
STATUS deprecated
DESCRIPTION
"The compliance statement for entities which implement
the Cisco Environmental Monitor MIB. This is
deprecated and new compliance
ciscoEnvMonMIBComplianceRev1 is added."
MODULE -- this module
MANDATORY-GROUPS { ciscoEnvMonMIBGroup }
::= { ciscoEnvMonMIBCompliances 1 }
ciscoEnvMonMIBComplianceRev1 MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for entities which implement
the Cisco Environmental Monitor MIB."
MODULE -- this module
MANDATORY-GROUPS { ciscoEnvMonMIBGroupRev,
ciscoEnvMonMIBNotifGroup }
GROUP ciscoEnvMonEnableStatChangeGroup
DESCRIPTION
"The ciscoEnvMonEnableStatChangeGroup is optional.
This group is applicable for implementations which
need status change notifications for environmental
monitoring."
GROUP ciscoEnvMonStatChangeNotifGroup
DESCRIPTION
"The ciscoEnvMonStatChangeNotifGroup is optional.
This group is applicable for implementations which
need status change notifications for environmental
monitoring."
::= { ciscoEnvMonMIBCompliances 2 }
-- units of conformance
ciscoEnvMonMIBGroup OBJECT-GROUP
OBJECTS {
ciscoEnvMonPresent,
ciscoEnvMonVoltageStatusDescr,
ciscoEnvMonVoltageStatusValue,
ciscoEnvMonVoltageThresholdLow,
ciscoEnvMonVoltageThresholdHigh,
ciscoEnvMonVoltageLastShutdown,
ciscoEnvMonVoltageState,
ciscoEnvMonTemperatureStatusDescr,
ciscoEnvMonTemperatureStatusValue,
ciscoEnvMonTemperatureThreshold,
ciscoEnvMonTemperatureLastShutdown,
ciscoEnvMonTemperatureState,
ciscoEnvMonFanStatusDescr,
ciscoEnvMonFanState,
ciscoEnvMonSupplyStatusDescr,
ciscoEnvMonSupplyState,
ciscoEnvMonSupplySource,
ciscoEnvMonAlarmContacts,
ciscoEnvMonEnableShutdownNotification,
ciscoEnvMonEnableVoltageNotification,
ciscoEnvMonEnableTemperatureNotification,
ciscoEnvMonEnableFanNotification,
ciscoEnvMonEnableRedundantSupplyNotification
}
STATUS deprecated
DESCRIPTION
"A collection of objects providing environmental
monitoring capability to a cisco chassis. This group
is deprecated in favour of ciscoEnvMonMIBGroupRev."
::= { ciscoEnvMonMIBGroups 1 }
ciscoEnvMonMIBGroupRev OBJECT-GROUP
OBJECTS {
ciscoEnvMonPresent,
ciscoEnvMonVoltageStatusDescr,
ciscoEnvMonVoltageStatusValue,
ciscoEnvMonVoltageThresholdLow,
ciscoEnvMonVoltageThresholdHigh,
ciscoEnvMonVoltageLastShutdown,
ciscoEnvMonVoltageState,
ciscoEnvMonTemperatureStatusDescr,
ciscoEnvMonTemperatureStatusValue,
ciscoEnvMonTemperatureThreshold,
ciscoEnvMonTemperatureLastShutdown,
ciscoEnvMonTemperatureState,
ciscoEnvMonFanStatusDescr,
ciscoEnvMonFanState,
ciscoEnvMonSupplyStatusDescr,
ciscoEnvMonSupplyState,
ciscoEnvMonSupplySource,
ciscoEnvMonAlarmContacts,
ciscoEnvMonEnableShutdownNotification
}
STATUS current
DESCRIPTION
"A collection of objects providing environmental
monitoring capability to a cisco chassis."
::= { ciscoEnvMonMIBGroups 2 }
ciscoEnvMonEnableStatChangeGroup OBJECT-GROUP
OBJECTS {
ciscoEnvMonEnableStatChangeNotif
}
STATUS current
DESCRIPTION
"A collection of objects providing enabling/disabling
of the status change notifications for environmental
monitoring."
::= { ciscoEnvMonMIBGroups 3 }
ciscoEnvMonMIBNotifGroup NOTIFICATION-GROUP
NOTIFICATIONS {
ciscoEnvMonShutdownNotification
}
STATUS current
DESCRIPTION
"A notification group providing shutdown notification
for environmental monitoring. "
::= { ciscoEnvMonMIBGroups 4 }
ciscoEnvMonStatChangeNotifGroup NOTIFICATION-GROUP
NOTIFICATIONS {
ciscoEnvMonVoltStatusChangeNotif,
ciscoEnvMonTempStatusChangeNotif,
ciscoEnvMonFanStatusChangeNotif,
ciscoEnvMonSuppStatusChangeNotif
}
STATUS current
DESCRIPTION
"A collection of notifications providing the status
change for environmental monitoring."
::= { ciscoEnvMonMIBGroups 5 }
ciscoEnvMonMIBMiscNotifGroup NOTIFICATION-GROUP
NOTIFICATIONS {
ciscoEnvMonVoltageNotification,
ciscoEnvMonTemperatureNotification,
ciscoEnvMonFanNotification,
ciscoEnvMonRedundantSupplyNotification
}
STATUS deprecated
DESCRIPTION
"A collection of various notifications for the
enviromental monitoring mib module. The notifications
the group and the group are both in deprecated state.
The notifications in the group were deprecated in
favour of notifications in
ciscoEnvMonStatChangeNotifGroup."
::= { ciscoEnvMonMIBGroups 6 }
END