RAPID-CITY DEFINITIONS ::= BEGIN IMPORTS MODULE-IDENTITY, OBJECT-TYPE, Gauge32, Counter32, Integer32, enterprises, IpAddress, TimeTicks FROM SNMPv2-SMI TEXTUAL-CONVENTION, RowStatus, TruthValue, MacAddress, DisplayString FROM SNMPv2-TC InterfaceIndex FROM IF-MIB SnmpAdminString,SnmpSecurityLevel,SnmpSecurityModel FROM SNMP-FRAMEWORK-MIB InetAddressType, InetAddress, InetPortNumber, InetAddressPrefixLength FROM INET-ADDRESS-MIB Ipv6Address FROM IPV6-TC; rapidCity MODULE-IDENTITY LAST-UPDATED "200510210000Z" ORGANIZATION "Bay Networks, Rapid-City Group" CONTACT-INFO "Yu-Ten Lee Postal: Nortel Networks, Inc. 4655 Great America Parkway Santa Clara, CA 95052-8185 Tel: 408-495-2560 Fax: 408-495-6680 E-mail: ylee@baynetworks.com" DESCRIPTION "Enterprise MIB for the Accelar product family." REVISION "200510210000Z" DESCRIPTION "Verion 46: Added new mibs rcFlowClassifier for 1600" REVISION "200509300000Z" -- 30 Sep 2005 DESCRIPTION "Version 45: Modified rcSysDnsServerListTable, sorted objects in rcChassis, & added rcChasSystemMonitorEnable" REVISION "200509200000Z" -- 20 Sep 2005 DESCRIPTION "Version 44: Added Ipv6 attributes to various tables" REVISION "200509090000Z" -- 09 Sep 2005 DESCRIPTION "Version 43: Added rcSysVirtualIpv6PrefixLength & rcSysVirtualIpv6Addr" REVISION "200508290000Z" -- 29 Aug 2005 DESCRIPTION "Version 42: Added rcIsis & rcSlpp" REVISION "200507270000Z" -- 27 July 2005 DESCRIPTION "Version 41. Increased range for rcCardIndex" REVISION "200507190000Z" -- 19 Jul 2005 DESCRIPTION "Version 40. Added rcSysAccPolSnmpGrpTable.Included snmp-v3 under access policy service, removed the default value" REVISION "200506020000Z" -- 02 Jun 2005 DESCRIPTION "Version 39. Added rcChasMcastCheckPktEnable." REVISION "200505060000Z" -- 06 May 2005 DESCRIPTION "Version 39. Added rcSysFrcMsgControlTable." REVISION "200504270000Z" -- 27 Apr 2005 DESCRIPTION "Version 38. Allow 0 length rsa and dsa key sizes." REVISION "200504210000Z" -- 21 Apr 2005 DESCRIPTION "Version 37. Fixed typos, added rcIpfix." REVISION "200504140000Z" -- 14 Apr 2005 DESCRIPTION "Version 36. Modified rcSysAccessPolicyService & rcSyslogHostSeverity mib objects." REVISION "200503210000Z" -- 21 Mar 2005 DESCRIPTION "Version 35: added rcLacpGlobalVlacpMulticastMACAddress." REVISION "200502220000Z" -- 22 Feb 2005 DESCRIPTION "Version 34: Changed PortSet definition" REVISION "200502181200Z" -- 18 Feb 2005 DESCRIPTION "Version 33: Added support for Tacacs" REVISION "200502171200Z" -- 17 Feb 2005 DESCRIPTION "Version 32: Updated teritory to tertiary" REVISION "200502150000Z" -- 15 Feb 2005 DESCRIPTION "Version 31: Added rcEsu1800dc" REVISION "200502110000Z" -- 11 Feb 2005 DESCRIPTION "Version 30: Added rcSystem 92 & 93" REVISION "200502040000Z" -- 04 Feb 2005 DESCRIPTION "Version 29: Changed range of rcSysVersion, rcCardSerialNumber, rcChasPowerSupplyDetailSerialNumber, rcChasPowerSupplyDetailHardwareRevision, rcChasPowerSupplyDetailPartNumber, rcCardSerialNumber" REVISION "200501160000Z" -- 16 January 2005 DESCRIPTION "Version 28: Added rcSysPowerUsage and rcSysPowerAvailable" REVISION "200412210000Z" -- 21 December 2004 DESCRIPTION "Version 27: Deprecated rcSysAction. Added rcSysExtCplimitSysOctapidCongested, rcSysExtCplimitPortsMonitored, rcSysExtCplimitPortsShutDown, rcSysActionL1, rcSysActionL2, rcSysActionL3, rcSysActionRwa " REVISION "200411230000Z" -- 23 November 2004 DESCRIPTION "Version 26: Added rcEsu1850 and rcEsu1850dc for ESU device" REVISION "200411110000Z" -- 11 November 2004 DESCRIPTION "Version 25: Cleaned up REVISIONs and fixed typo." REVISION "200411040000Z" -- 04 November 2004 DESCRIPTION "Version 24: Added rcSysExtCplimitEnable,rcSysExtCplimitMinCongTime, rcSysExtCplimitMaxPorts, rcSysExtCplimitPortCongTime, rcSysExtCplimitTrapLevel." REVISION "200409300000Z" -- 30 September 2004 DESCRIPTION "Version 22: Fixed type mismatch for mib rcSysDnsServerListRequestCount/SuccessCount" REVISION "200409280000Z" -- 28 September 2004 DESCRIPTION "Version 21: Update enum value for mib rcSysDnsServerListType, update syntax type for RequestCount, SuccessCount, change rcRepeaterTable OID and add new mib rcChasNewGlobalFilterOrderingEnable." REVISION "200409230000Z" -- 23 September 2004 DESCRIPTION "Version 20: Add range for rcAgentId." REVISION "200409210000Z" -- 21 September 2004 DESCRIPTION "Version 19: Remove range for rcAgentId." REVISION "200409130001Z" -- 13 September 2004 DESCRIPTION "Version 18: Added rcCliRWEnable, rcCliRWL1Enable, rcCliRWL2Enable, rcCliRWL3Enable, rcCliROEnable." REVISION "200409130000Z" -- 13 September 2004 DESCRIPTION "Version 17: Added rcSysAutoRecoverDelay, rcSysMacFlapLimitTime, rcSysMacFlapLimitCount" REVISION "200408310000Z" -- 31 August 2004 DESCRIPTION "Version 16: Change rcVlacpPeerMacAddressMltIds to rcVlacpPeerMacAddressMltId with SYNTAX INTEGER and rcVlacpPeerMacAddressPort with SYNTAX InterfaceIndex" REVISION "200407070000Z" -- 07 July 2004 DESCRIPTION "Version 15: Added rcVlacpPeerMacAddressTable" REVISION "200407060000Z" -- 06 July 2004 DESCRIPTION "Version 14: Added Poe card type poe1400WPS(0x109e3100)" REVISION "200406240000Z" -- 24 June 2004 DESCRIPTION "Version 13: Added rcSysSpanningTreeOperMode and rcSysSpanningTreeAdminMode" REVISION "200406110000Z" -- 11 June 2004 DESCRIPTION "Version 12: Added rcChasRspMode, rcChasRspOperMode, and rcChasRspModeError objects" ::= { enterprises 2272 } -- -- Textual Conventions -- EnableValue ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "Enable/Disable value." SYNTAX INTEGER { enable(1), disable(2) } PortSet ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "The string is 88 octets long, for a total of 704 bits. Each bit corresponds to a port, as represented by its ifIndex value . When a bit has the value one(1), the corresponding port is a member of the set. When a bit has the value zero(0), the corresponding port is not a member of the set. The encoding is such that the most significant bit of octet #1 corresponds to ifIndex 0, while the least significant bit of octet #88 corresponds to ifIndex 703. In order to accommodate future uses of this the string has a max size of 255 bytes." SYNTAX OCTET STRING (SIZE (0..255)) IdList ::= TEXTUAL-CONVENTION STATUS current DESCRIPTION "" SYNTAX OCTET STRING (SIZE(0..8192)) -- -- Enterprise specific MIB groups -- rcMgmt OBJECT IDENTIFIER ::= { rapidCity 1 } rcA1100 OBJECT IDENTIFIER ::= { rapidCity 2 } rcA1250 OBJECT IDENTIFIER ::= { rapidCity 6 } rcA1150 OBJECT IDENTIFIER ::= { rapidCity 7 } rcA1200 OBJECT IDENTIFIER ::= { rapidCity 8 } rcA1050 OBJECT IDENTIFIER ::= { rapidCity 9 } rcA740 OBJECT IDENTIFIER ::= { rapidCity 20 } rcA750 OBJECT IDENTIFIER ::= { rapidCity 21 } rcA790 OBJECT IDENTIFIER ::= { rapidCity 22 } rcA750S OBJECT IDENTIFIER ::= { rapidCity 23 } rcA8003 OBJECT IDENTIFIER ::= { rapidCity 280887555 } rcA8006 OBJECT IDENTIFIER ::= { rapidCity 280887558 } rcA8010 OBJECT IDENTIFIER ::= { rapidCity 280887562 } rcA8010co OBJECT IDENTIFIER ::= { rapidCity 1623064842 } rcA8610 OBJECT IDENTIFIER ::= { rapidCity 30 } rcA8606 OBJECT IDENTIFIER ::= { rapidCity 31 } rcA8110 OBJECT IDENTIFIER ::= { rapidCity 32 } rcA8106 OBJECT IDENTIFIER ::= { rapidCity 33 } rcA8603 OBJECT IDENTIFIER ::= { rapidCity 34 } rcA8103 OBJECT IDENTIFIER ::= { rapidCity 35 } rcA8110co OBJECT IDENTIFIER ::= { rapidCity 36 } rcA8610co OBJECT IDENTIFIER ::= { rapidCity 37 } -- This is a place holder for OM 2.0 chassises -- NOTE that { rapidCity 40 } is also used for the rcBayStack branch, -- and so we must be sure that nothing ever gets defined under rcAom8003 -- in order to avoid any conflicts. --rcAom8010 OBJECT IDENTIFIER ::= { rapidCity 38 } --rcAom8010co OBJECT IDENTIFIER ::= { rapidCity 39 } rcBayStack OBJECT IDENTIFIER ::= { rapidCity 40 } --rcAom8006 OBJECT IDENTIFIER ::= { rapidCity 41 } rcA1424 OBJECT IDENTIFIER ::= { rapidCity 42 } rcA1648 OBJECT IDENTIFIER ::= { rapidCity 43 } rcA1612 OBJECT IDENTIFIER ::= { rapidCity 44 } rcA1624 OBJECT IDENTIFIER ::= { rapidCity 45 } rcRBS2402 OBJECT IDENTIFIER ::= { rapidCity 46 } rcAtr8310 OBJECT IDENTIFIER ::= { rapidCity 47 } rcAtr8306 OBJECT IDENTIFIER ::= { rapidCity 48 } rcAtr8010 OBJECT IDENTIFIER ::= { rapidCity 49 } rcAtr8006 OBJECT IDENTIFIER ::= { rapidCity 50 } rcEsu1850 OBJECT IDENTIFIER ::= { rapidCity 51 } rcEsu1850dc OBJECT IDENTIFIER ::= { rapidCity 52 } rcEsu1800dc OBJECT IDENTIFIER ::= { rapidCity 53 } -- From rapidCity 100 to rapidCity 200 is reserved for OM chassises -- -- MIB groups. Note that the ones that are commented out are now defined in -- separate MIB files. These are kept as placeholders here. -- rcSystem OBJECT IDENTIFIER ::= { rcMgmt 1 } rcTftp OBJECT IDENTIFIER ::= { rcMgmt 2 } rcVlan OBJECT IDENTIFIER ::= { rcMgmt 3 } rcChassis OBJECT IDENTIFIER ::= { rcMgmt 4 } rcMirror OBJECT IDENTIFIER ::= { rcMgmt 5 } rcDipSwitch OBJECT IDENTIFIER ::= { rcMgmt 6 } rcTblSize OBJECT IDENTIFIER ::= { rcMgmt 7 } rcIp OBJECT IDENTIFIER ::= { rcMgmt 8 } rcArp OBJECT IDENTIFIER ::= { rcMgmt 9 } rcRip OBJECT IDENTIFIER ::= { rcMgmt 10 } rcTest OBJECT IDENTIFIER ::= { rcMgmt 11 } rcStat OBJECT IDENTIFIER ::= { rcMgmt 12 } rcStg OBJECT IDENTIFIER ::= { rcMgmt 13 } rcBridge OBJECT IDENTIFIER ::= { rcMgmt 14 } rcBoot OBJECT IDENTIFIER ::= { rcMgmt 15 } rcDevice OBJECT IDENTIFIER ::= { rcMgmt 16 } rcMlt OBJECT IDENTIFIER ::= { rcMgmt 17 } rcWeb OBJECT IDENTIFIER ::= { rcMgmt 18 } rcCli OBJECT IDENTIFIER ::= { rcMgmt 19 } rcError OBJECT IDENTIFIER ::= { rcMgmt 20 } rcTraps OBJECT IDENTIFIER ::= { rcMgmt 21 } rcSyslog OBJECT IDENTIFIER ::= { rcMgmt 22 } rcDiag OBJECT IDENTIFIER ::= { rcMgmt 23 } rcIpx OBJECT IDENTIFIER ::= { rcMgmt 24 } rcPos OBJECT IDENTIFIER ::= { rcMgmt 26 } rcLinkFlapDetect OBJECT IDENTIFIER ::= { rcMgmt 27 } rcV1Traps OBJECT IDENTIFIER ::= { rcMgmt 28 } rcRadius OBJECT IDENTIFIER ::= { rcMgmt 29 } rcIgmp OBJECT IDENTIFIER ::= { rcMgmt 30 } rcUserSetTime OBJECT IDENTIFIER ::= { rcMgmt 31 } rcL2Redundancy OBJECT IDENTIFIER ::= { rcMgmt 32 } rcNtp OBJECT IDENTIFIER ::= { rcMgmt 33 } rcSsh OBJECT IDENTIFIER ::= { rcMgmt 34 } rcSvlan OBJECT IDENTIFIER ::= { rcMgmt 35 } rcOpm OBJECT IDENTIFIER ::= { rcMgmt 36 } rcVpn OBJECT IDENTIFIER ::= { rcMgmt 37 } rcOeAdm OBJECT IDENTIFIER ::= { rcMgmt 38 } rcTlsVpn OBJECT IDENTIFIER ::= { rcMgmt 39 } rcTls OBJECT IDENTIFIER ::= { rcMgmt 40 } rcCos OBJECT IDENTIFIER ::= { rcMgmt 41 } rcBanRing OBJECT IDENTIFIER ::= { rcMgmt 42 } rcTengEnet OBJECT IDENTIFIER ::= { rcMgmt 50 } rcRec OBJECT IDENTIFIER ::= { rcMgmt 51 } rcTdc OBJECT IDENTIFIER ::= { rcMgmt 52 } rcLacp OBJECT IDENTIFIER ::= { rcMgmt 53 } rcQos OBJECT IDENTIFIER ::= { rcMgmt 54 } rcFilter OBJECT IDENTIFIER ::= { rcMgmt 55 } rcLicense OBJECT IDENTIFIER ::= { rcMgmt 56 } rcEap OBJECT IDENTIFIER ::= { rcMgmt 57 } rcMcast OBJECT IDENTIFIER ::= { rcMgmt 58 } rcOspf OBJECT IDENTIFIER ::= { rcMgmt 59 } rcFdb OBJECT IDENTIFIER ::= { rcMgmt 60 } rcIgap OBJECT IDENTIFIER ::= { rcMgmt 61 } rcIpv6 OBJECT IDENTIFIER ::= { rcMgmt 62 } rcIsis OBJECT IDENTIFIER ::= { rcMgmt 63 } rcSlpp OBJECT IDENTIFIER ::= { rcMgmt 64 } rcTacacs OBJECT IDENTIFIER ::= { rcMgmt 65 } rcIpfix OBJECT IDENTIFIER ::= { rcMgmt 66 } rcOspfv3 OBJECT IDENTIFIER ::= { rcMgmt 67 } rcFlowClassifier OBJECT IDENTIFIER ::= { rcMgmt 68 } rc2k OBJECT IDENTIFIER ::= { rcMgmt 100 } rcOm8k OBJECT IDENTIFIER ::= { rcMgmt 200 } cobra OBJECT IDENTIFIER ::= { rcMgmt 201 } rcPowerRanger OBJECT IDENTIFIER ::= { rcMgmt 202 } -- LOGICAL (System) Elements rcSysIpAddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "This entity's IP address." ::= { rcSystem 1 } rcSysNetMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "This entity's subnet mask." ::= { rcSystem 2 } rcSysBroadcast OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "This entity's broadcast address." ::= { rcSystem 3 } -- Community Strings rcSysCommReadWriteAll OBJECT-TYPE SYNTAX DisplayString (SIZE (0..20)) MAX-ACCESS read-write STATUS current DESCRIPTION "When an SNMP message is received by this entity, the community string in the message is compared with this string first. If it matches, read-write access is granted to all items in the MIB. If it doesn't match, the rcSysCommReadWrite string is compared next." ::= { rcSystem 4 } rcSysCommReadWrite OBJECT-TYPE SYNTAX DisplayString (SIZE (0..20)) MAX-ACCESS read-write STATUS current DESCRIPTION "When an SNMP message is received by this entity, the community string in the message is compared with this string second. If it matches, read-write access is granted to all items in the MIB except community strings. (Community strings appear empty when read and return a no such name error when an attempt is made to write them.) If it doesn't match, the rcSysCommReadWriteLayer3 string is compared next." ::= { rcSystem 5 } rcSysCommReadOnly OBJECT-TYPE SYNTAX DisplayString (SIZE (0..20)) MAX-ACCESS read-write STATUS current DESCRIPTION "When an SNMP message is received by this entity, the community string in the message is compared with this string third. If it matches, read-only access is granted to all items in the MIB except community strings. (Community strings appear empty when read.) If it doesn't match, no access is granted, no response is sent back to the SNMP requester, and SNMP traps are sent to the SNMP trap receiver(s) if configured." ::= { rcSystem 6 } -- Other rcSysVersion OBJECT-TYPE SYNTAX DisplayString (SIZE (0..80)) MAX-ACCESS read-only STATUS current DESCRIPTION "Software version running on device" ::= { rcSystem 7 } rcSysAction OBJECT-TYPE SYNTAX INTEGER { none(1), -- none of the following hardReset(2), -- power on tests softReset(3), -- reset w/o power on tests saveToNVRAM(4), -- save current config to NVRAM resetCounters(5), -- reset all statistic counters saveToStandbyNVRAM(6), -- save config to slave NVRAM cpuSwitchOver(7), -- CPU board switch-over checkSwInFlash(8), checkSwInPcmcia(9), resetConsole(10), resetModem(11), flushIpRouteTbl(12), saveRuntimeConfig(13), -- 8k only saveRuntimeConfigToSlave(14), -- 8k only saveBootConfig(15), -- 8k only saveSlaveBootConfig(16), -- 8k only resetIstStatCounters(17), -- being used in rel2.2(18) -- being used in rel2.2(19) -- reserve(20) -- reserve(21) resetEsmPortStats(22) } MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Initiate a system action." DEFVAL { none } ::= { rcSystem 8 } rcSysResult OBJECT-TYPE SYNTAX INTEGER { none(1), -- none of the following inProgress(2), -- in progress success(3), -- success fail(4), -- failure flashReadFailed(5), -- could not read from flash pcmciaReadFailed(6), -- could not read from pcmcia crcCheckFailed(7), noStandbyCpu(8) } MAX-ACCESS read-only STATUS current DESCRIPTION "Result from the last system action." DEFVAL { none } ::= { rcSystem 9 } rcSysLastChange OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "Last management initiated configuration change since sysUpTime." ::= { rcSystem 10 } rcSysLastVlanChange OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "Last management initiated VLAN configuration change since sysUpTime." ::= { rcSystem 11 } rcSysLastStatisticsReset OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "Last management initiated statistics reset since sysUpTime." ::= { rcSystem 12 } -- Global Statistics rcSysBufferUtil OBJECT-TYPE SYNTAX INTEGER (0..100) MAX-ACCESS read-only STATUS current DESCRIPTION "Buffer utilization as a percentage of the total amount of buffer space in the system. A high value indicates congestion." ::= { rcSystem 13 } rcSysBufferUtilPeak OBJECT-TYPE SYNTAX INTEGER (0..100) MAX-ACCESS read-only STATUS current DESCRIPTION "The largest buffer utilization since sysUpTime" ::= { rcSystem 14 } rcSysBufferUtilPeakTime OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "Timestamp for rcSysPeakBandwidth" ::= { rcSystem 15 } rcSysNVRamSize OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Total Non-volatile RAM in Kbytes" ::= { rcSystem 16 } rcSysNVRamUsed OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Non-volatile RAM in use in Kbytes" ::= { rcSystem 17 } rcSysLastSaveToNVRam OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "SysUpTime of the last time when NVRAM was written to. This could be a save of the system configuration or via a file transfer of a configuration file." ::= { rcSystem 18 } rcSysLastSaveToStandbyNVRam OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "SysUpTime of the last time when the standby NVRAM (on the back-up CPU board) was written to." ::= { rcSystem 19 } rcSysCpuUtil OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Percentage of CPU utilization" ::= { rcSystem 20 } rcSysSwitchFabricUtil OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Percentage of Switching Fabric utilization" ::= { rcSystem 21 } rcSysRmonMemSize OBJECT-TYPE SYNTAX INTEGER (250000..4000000) MAX-ACCESS read-write STATUS current DESCRIPTION "Amount of RAM in bytes to allocate for RMON to use when rcSysRmonEnable is TRUE." ::= { rcSystem 22 } rcSysRmonEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Control whether the RMON feature should be enabled. To enable the RMON feature, set this variable to true. The RMON agent in the device will get started immediately if the amount of memory specified by rcSysRmonMemSize is currently available in the device. To disable the RMON feature, set this variable to false, save the new setting to NVRAM, and reboot the device. After the device is rebooted the RMON agent will not be operational." ::= { rcSystem 23 } rcSysRmonSaveConfig OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Control whether RMON configuration information should be saved to NVRAM so RMON settings can be automatically reinstalled after a system reboot. Setting rcSysRmonSaveConfig to true does not immediately save the configuration information. The save happens when the rcSysAction variable is set to 'saveToNVRAM(4)'. This option is only meaningful when the rcSysRmonEnable variable is set to true." ::= { rcSystem 24 } rcSysRmonTrapOption OBJECT-TYPE SYNTAX INTEGER { toOwner(1), toAll(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Used to indicate whether RMON traps should be sent to only the owner of the RMON alarm (i.e., the manager that created the alarm entry) or all trap recipients in the system trap receiver table." DEFVAL { toOwner } ::= { rcSystem 25 } rcSysSupportRouting OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Used to indicate whether routing is supported in this product." ::= { rcSystem 26 } rcSysSupportWebServer OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Used to indicate whether WebServer is supported in this product." ::= { rcSystem 27 } rcSysLastIpAddrChange OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "Last management initiated IP address change since sysUpTime. Any addition or deletion of an IP address to a single routable port or a VLAN is time-stamped by this variable." ::= { rcSystem 28 } rcSysCommReadWriteLayer3 OBJECT-TYPE SYNTAX DisplayString (SIZE (0..20)) MAX-ACCESS read-write STATUS current DESCRIPTION "When an SNMP message is received by this entity, the community string in the message is compared with this string third. If it matches, read-write access is granted to all Layer-3 items in the MIB except community strings. (Community strings appear empty when read and return a no such name error when an attempt is made to write them.) If it doesn't match, the rcSysCommReadWriteLayer2 string is compared next." ::= { rcSystem 29 } rcSysCommReadWriteLayer2 OBJECT-TYPE SYNTAX DisplayString (SIZE (0..20)) MAX-ACCESS read-write STATUS current DESCRIPTION "When an SNMP message is received by this entity, the community string in the message is compared with this string fourth. If it matches, read-write access is granted to all Layer-2 items in the MIB except community strings. (Community strings appear empty when read and return a no such name error when an attempt is made to write them.) If it doesn't match, the rcSysCommReadOnly string is compared next." ::= { rcSystem 30 } rcSysAccessPolicyEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Used to configure the system access policy feature. if 'true', the rcSysAccessPolicyTable is examined to determine which packets should be allowed or denied access to this device." DEFVAL { false } ::= { rcSystem 31 } rcSysDefaultRuntimeConfigFileName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "default config." ::= { rcSystem 32 } rcSysDefaultBootConfigFileName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "default boot config." ::= { rcSystem 33 } rcSysConfigFileName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "File name used in conjunction with rcSysAction. If rcSysAction is set to 'saveRuntimeConfig' or 'saveRuntimeConfigToSlave' then this file name will be used instead of the file name specified in rcSysDefaultRuntimeConfigFileName. If rcSysAction is set to 'saveBootConfig' or 'saveBootConfigToSlave' then this file name will be used insteaad of the file name specified in rcSysDefaultBootConfigFileName. If the file name is blank (i.e., nothing is entered) then the default file name will be used." ::= { rcSystem 34 } rcSysLastRunTimeConfigSave OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "SysUpTime of the last time when the run time configuration was written to." ::= { rcSystem 35 } rcSysLastRunTimeConfigSaveToSlave OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "SysUpTime of the last time when the run time configuration was written to slave NVRAM." ::= { rcSystem 36 } rcSysLastBootConfigSave OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "SysUpTime of the last time when the boot configuration was written to." ::= { rcSystem 37 } rcSysLastBootConfigSaveOnSlave OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "SysUpTime of the last time when the boot configuration was written on the slave NVRAM." ::= { rcSystem 38 } rcSysRmonUtilizationMethod OBJECT-TYPE --excluded SYNTAX INTEGER { halfDuplex(1), fullDuplex(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Used to control whether RMON should use a half-duplex or full-duplex formula to calculate port utilization. When set to 'halfDuplex', RMON will use InOctets and the port's speed to calculate port utilization (this is the standard RMON rfc1271 convention). When set to 'fullDuplex', RMON will use InOctets and OutOctets and 2X the port's speed to calculate port utilization. Furthermore, if this variable is set to 'fullDuplex', but the port is operating in a half-duplex mode, the calculation defaults back to the rfc1271 convention." DEFVAL { halfDuplex } ::= { rcSystem 39 } rcSysCommReadWriteLayer1 OBJECT-TYPE SYNTAX DisplayString (SIZE (0..20)) MAX-ACCESS read-write STATUS current DESCRIPTION "read-write L1 access" ::= { rcSystem 40 } rcSysOtherBufferUtil OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "bw currently consumed" ::= { rcSystem 41 } rcSysOtherBufferUtilPeak OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "peak bw since reset" ::= { rcSystem 42 } rcSysOtherBufferUtilPeakTime OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "timestamp for rcSysPeakBw" ::= { rcSystem 43 } rcSysOtherCpuUtil OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "% cpu utilization" ::= { rcSystem 44 } rcSysOtherSwitchFabricUtil OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "% switch fabric util" ::= { rcSystem 45 } rcSysDramSize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Dram size in mega-bytes" ::= { rcSystem 46 } rcSysDramUsed OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Dram used in percentage" ::= { rcSystem 47 } rcSysDramFree OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Dram free size in kilo-bytes" ::= { rcSystem 48 } rcSysDramMaxBlockFree OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Dram max block free size in kilo-bytes" ::= { rcSystem 49 } rcSysVirtualIpAddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Virtual IP is an IP address that owned and advertised only by the master CPU. So whichever CPU is master registers this IP address. Unlike the management IP address, this address goes in the switch config file and not the boot config" ::= { rcSystem 51 } rcSysVirtualNetMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Net mask of the management virtual Ip address" ::= { rcSystem 52 } rcSysReadWriteLevel OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The status of the read/write level" ::= { rcSystem 53 } rcSysMTUSize OBJECT-TYPE SYNTAX INTEGER { mtu1950(1), mtu9600(2), mtu1522(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "This is the maximum transmission size of frames that all the ports on the chassis support." DEFVAL { mtu1950 } ::= { rcSystem 55 } rcSysClockSyncTime OBJECT-TYPE SYNTAX INTEGER (15..3600) MAX-ACCESS read-write STATUS current DESCRIPTION "Time interval at which RTC and system clocks are synchronized." DEFVAL { 60 } ::= { rcSystem 56 } rcSysForceTrapSender OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is a flag that if user wants to configured CLIP (Circuit Less IP) as trap originator." ::= { rcSystem 57 } rcSysMrouteStrLimit OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "enable or disable mroute stream limit in system." DEFVAL { false } ::= { rcSystem 58 } -- Trap Receiver Table rcSysTrapRecvTable OBJECT-TYPE SYNTAX SEQUENCE OF RcSysTrapRecvEntry MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION "The trap receiver table (0 to 25 entries). This table lists the addresses of Network Management Stations that should receive trap messages from this entity when an exception condition occurs." ::= { rcSystem 60 } rcSysTrapRecvEntry OBJECT-TYPE SYNTAX RcSysTrapRecvEntry MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION "A trap receiver table entry." INDEX { rcSysTrapRecvAddress } ::= { rcSysTrapRecvTable 1 } RcSysTrapRecvEntry ::= SEQUENCE { rcSysTrapRecvAddress IpAddress, rcSysTrapRecvVersion INTEGER, rcSysTrapRecvCommunity DisplayString, rcSysTrapRecvSrcAddress IpAddress, rcSysTrapRecvRowStatus RowStatus } rcSysTrapRecvAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS deprecated DESCRIPTION "IP address for trap receiver." ::= { rcSysTrapRecvEntry 1 } rcSysTrapRecvVersion OBJECT-TYPE SYNTAX INTEGER { v1(1), v2c(2) } MAX-ACCESS read-write STATUS deprecated DESCRIPTION "The version of trap receiver." DEFVAL { v1 } ::= { rcSysTrapRecvEntry 2 } rcSysTrapRecvCommunity OBJECT-TYPE SYNTAX DisplayString (SIZE (0..20)) MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Community string used for trap messages to this trap receiver." ::= { rcSysTrapRecvEntry 3 } rcSysTrapRecvSrcAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Source IP address to use when sending traps. This IP address will be inserted into the source IP address field in the UDP trap packet." ::= { rcSysTrapRecvEntry 4 } rcSysTrapRecvRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Used to create/delete entries" ::= { rcSysTrapRecvEntry 5 } -- Access Policy Table rcSysAccessPolicyTable OBJECT-TYPE SYNTAX SEQUENCE OF RcSysAccesspolicyEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Management access policy table. This table is used to permit or deny access to this device via the specified source Id." ::= { rcSystem 61 } rcSysAccessPolicyEntry OBJECT-TYPE SYNTAX RcSysAccesspolicyEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "An access policy table entry." INDEX { rcSysAccessPolicyId } ::= { rcSysAccessPolicyTable 1 } RcSysAccesspolicyEntry ::= SEQUENCE { rcSysAccessPolicyId INTEGER, rcSysAccessPolicyName DisplayString, rcSysAccessPolicyPolicyEnable TruthValue, rcSysAccessPolicyMode INTEGER, rcSysAccessPolicyService INTEGER, rcSysAccessPolicyPrecedence INTEGER, rcSysAccessPolicyNetAddr IpAddress, rcSysAccessPolicyNetMask IpAddress, rcSysAccessPolicyTrustedHostAddr IpAddress, rcSysAccessPolicyTrustedHostUserName DisplayString, rcSysAccessPolicyAccessLevel INTEGER, rcSysAccessPolicyLog TruthValue, rcSysAccessPolicyUsage Counter32, rcSysAccessPolicyRowStatus RowStatus, rcSysAccessPolicyAccessStrict TruthValue, rcSysAccessPolicyNetInetAddrType InetAddressType, rcSysAccessPolicyNetInetAddress InetAddress, rcSysAccessPolicyNetInetAddrPrefixLen InetAddressPrefixLength, rcSysAccessPolicyTrustedHostInetAddress InetAddress } rcSysAccessPolicyId OBJECT-TYPE SYNTAX INTEGER (1..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "Policy Id." ::= { rcSysAccessPolicyEntry 1 } rcSysAccessPolicyName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..15)) MAX-ACCESS read-write STATUS current DESCRIPTION "Name of this policy." ::= { rcSysAccessPolicyEntry 2 } rcSysAccessPolicyPolicyEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Indicate whether this policy is currently active." DEFVAL { true } ::= { rcSysAccessPolicyEntry 3 } rcSysAccessPolicyMode OBJECT-TYPE SYNTAX INTEGER { allow(1), deny(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Used to indicate whether a packet having a source IP address that matches this entry should be permitted to enter the device or denied access." DEFVAL { allow } ::= { rcSysAccessPolicyEntry 4 } rcSysAccessPolicyService OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-write STATUS current DESCRIPTION "Is represented as bitset to indicate which protocol this entry should be applied to. Value is one of multiple(logical 'OR') of the following values: telnet(1): enables telnet service snmp(2): enables snmp service tftp(4): enables tftp service ftp(8): enables ftp service http(16): enables http service rlogin(32): enables rlogin service ssh(64): enables ssh service snmp-v3(128): enables snmp service for v3 groups." ::= { rcSysAccessPolicyEntry 5 } rcSysAccessPolicyPrecedence OBJECT-TYPE SYNTAX INTEGER (1..128) MAX-ACCESS read-write STATUS current DESCRIPTION "Used to indicate the precedence of this policy. The Lower the number the higher the precedence." DEFVAL { 10 } ::= { rcSysAccessPolicyEntry 6 } rcSysAccessPolicyNetAddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Source network IP address." ::= { rcSysAccessPolicyEntry 7 } rcSysAccessPolicyNetMask OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Source network mask." ::= { rcSysAccessPolicyEntry 8 } rcSysAccessPolicyTrustedHostAddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Trusted IP address of host performing a rlogin into the device." ::= { rcSysAccessPolicyEntry 9 } rcSysAccessPolicyTrustedHostUserName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..30)) MAX-ACCESS read-write STATUS current DESCRIPTION "User name on the trusted host performing a rlogin into the device." ::= { rcSysAccessPolicyEntry 10 } rcSysAccessPolicyAccessLevel OBJECT-TYPE SYNTAX INTEGER { readOnly(1), readWrite(2), readWriteAll(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Access level of trusted host." DEFVAL { readOnly } ::= { rcSysAccessPolicyEntry 11 } rcSysAccessPolicyLog OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Used to indicate whether logging should be performed if this policy was applied." DEFVAL { false } ::= { rcSysAccessPolicyEntry 12 } rcSysAccessPolicyUsage OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Usage Counter" ::= { rcSysAccessPolicyEntry 13 } rcSysAccessPolicyRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-write STATUS current DESCRIPTION "Used to create/delete an entry" ::= { rcSysAccessPolicyEntry 14 } rcSysAccessPolicyAccessStrict OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Used to restrict the access level specified in the system access policy table to exactly the same access level as specified by user. If TRUE then only the access level in the policy table is allowed access. If FALSE, then the default behavior is to assume the access level specified in policy table as the floor." DEFVAL { false } ::= { rcSysAccessPolicyEntry 15 } rcSysAccessPolicyNetInetAddrType OBJECT-TYPE SYNTAX InetAddressType MAX-ACCESS read-write STATUS current DESCRIPTION "Source network Inet Address Type." ::= { rcSysAccessPolicyEntry 16 } rcSysAccessPolicyNetInetAddress OBJECT-TYPE SYNTAX InetAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Source network Inet Address (prefix/network)." ::= { rcSysAccessPolicyEntry 17 } rcSysAccessPolicyNetInetAddrPrefixLen OBJECT-TYPE SYNTAX InetAddressPrefixLength MAX-ACCESS read-write STATUS current DESCRIPTION "Source network Inet Address Prefix-Length/Mask." ::= { rcSysAccessPolicyEntry 18 } rcSysAccessPolicyTrustedHostInetAddress OBJECT-TYPE SYNTAX InetAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Trusted Inet address of host performing a rlogin into the device." ::= { rcSysAccessPolicyEntry 19 } -- Trap Sender Address Table rcSysTrapSenderTable OBJECT-TYPE SYNTAX SEQUENCE OF RcSysTrapSenderEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The trap sender table (0 to 25 entries). This table lists the addresses of Network Management Stations and the Source Address that should receive trap messages from this entity when an exception condition occurs." ::= { rcSystem 62 } rcSysTrapSenderEntry OBJECT-TYPE SYNTAX RcSysTrapSenderEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A trap sender table entry." INDEX { rcSysTrapSenderRecvAddress } ::= { rcSysTrapSenderTable 1 } RcSysTrapSenderEntry ::= SEQUENCE { rcSysTrapSenderRecvAddress IpAddress, rcSysTrapSenderSrcAddress IpAddress } rcSysTrapSenderRecvAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "IP address for trap receiver." ::= { rcSysTrapSenderEntry 1 } rcSysTrapSenderSrcAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "IP address for trap sender." ::= { rcSysTrapSenderEntry 2 } -- DNS Server List Mibs rcSysDnsServerListTableSize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Used to indicate the number of entries in the table." ::= { rcSystem 63 } rcSysDnsServerListTable OBJECT-TYPE SYNTAX SEQUENCE OF RcSysDnsServerListEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "DNS serever list table used to store the details of the DNS server configured." ::= { rcSystem 64 } rcSysDnsServerListEntry OBJECT-TYPE SYNTAX RcSysDnsServerListEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "table entry." INDEX {rcSysDnsServerListType} ::= { rcSysDnsServerListTable 1 } RcSysDnsServerListEntry ::= SEQUENCE { rcSysDnsServerListType INTEGER, rcSysDnsServerListIp IpAddress, -- deprecated rcSysDnsServerListStatus INTEGER, rcSysDnsServerListRequestCount Counter32, rcSysDnsServerListSuccessCount Counter32, rcSysDnsServerListRowStatus RowStatus, rcSysDnsServerListAddressType InetAddressType, rcSysDnsServerListAddress InetAddress } rcSysDnsServerListType OBJECT-TYPE SYNTAX INTEGER { primary(0), secondary(1), tertiary(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Type of the DNS server" ::= { rcSysDnsServerListEntry 1 } rcSysDnsServerListIp OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS deprecated DESCRIPTION "IP address of the DNS server" ::= { rcSysDnsServerListEntry 2 } rcSysDnsServerListStatus OBJECT-TYPE SYNTAX INTEGER { active(0), in-active(1) } MAX-ACCESS read-only STATUS current DESCRIPTION "Status of DNS server" ::= { rcSysDnsServerListEntry 3 } rcSysDnsServerListRequestCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of request send to this server" ::= { rcSysDnsServerListEntry 4 } rcSysDnsServerListSuccessCount OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of request send to this server which are successful" ::= { rcSysDnsServerListEntry 5 } rcSysDnsServerListRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-write STATUS current DESCRIPTION "Used to create/delete DNS server entries in rcSysDnsServerListTable." ::= { rcSysDnsServerListEntry 6 } rcSysDnsServerListAddressType OBJECT-TYPE SYNTAX InetAddressType MAX-ACCESS read-create STATUS current DESCRIPTION "The type of ip address configured by the DNS server" ::= { rcSysDnsServerListEntry 7 } rcSysDnsServerListAddress OBJECT-TYPE SYNTAX InetAddress MAX-ACCESS read-create STATUS current DESCRIPTION "The ip address configured by the DNS server" ::= { rcSysDnsServerListEntry 8 } -- DNS Host Table rcSysDnsHostTable OBJECT-TYPE SYNTAX SEQUENCE OF RcSysDnsHostEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "DNS Host table." ::= { rcSystem 65 } rcSysDnsHostEntry OBJECT-TYPE SYNTAX RcSysDnsHostEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "table entry." INDEX { rcSysDnsHostData } ::= { rcSysDnsHostTable 1 } RcSysDnsHostEntry ::= SEQUENCE { rcSysDnsHostData OCTET STRING, rcSysDnsHostName OCTET STRING, rcSysDnsHostIpAddress IpAddress, -- deprecated rcSysDnsHostSource OCTET STRING, rcSysDnsHostAddressType InetAddressType, rcSysDnsHostAddress InetAddress } rcSysDnsHostData OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..256)) MAX-ACCESS read-only STATUS current DESCRIPTION "Host Name or Host IP Address." ::= { rcSysDnsHostEntry 1 } rcSysDnsHostName OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..256)) MAX-ACCESS read-only STATUS current DESCRIPTION "Host Name." ::= { rcSysDnsHostEntry 2 } rcSysDnsHostIpAddress OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Host IP Address." ::= { rcSysDnsHostEntry 3 } rcSysDnsHostSource OBJECT-TYPE SYNTAX OCTET STRING (SIZE(0..256)) MAX-ACCESS read-only STATUS current DESCRIPTION "DNS Server IP or /etc/host file." ::= { rcSysDnsHostEntry 4 } rcSysDnsHostAddressType OBJECT-TYPE SYNTAX InetAddressType MAX-ACCESS read-only STATUS current DESCRIPTION "The type of ip address for the DNS host" ::= { rcSysDnsHostEntry 5 } rcSysDnsHostAddress OBJECT-TYPE SYNTAX InetAddress MAX-ACCESS read-only STATUS current DESCRIPTION "The ip address of the DNS host" ::= { rcSysDnsHostEntry 6 } rcSysMsgLogFrequency OBJECT-TYPE SYNTAX INTEGER (2..500) MAX-ACCESS read-only STATUS current DESCRIPTION "Used to specify the maximum frequency/count of the occurence of the Log Message." ::= { rcSystem 66 } rcSysMsgLogText OBJECT-TYPE SYNTAX DisplayString (SIZE(0..3)) MAX-ACCESS read-only STATUS current DESCRIPTION "A textual string containing the first four characters of the Log Message." ::= { rcSystem 67 } rcSysForceIpHdrSender OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Flag to decide if IP header source address will be matched with SNMP header sender networks." DEFVAL { false } ::= { rcSystem 68 } rcSysVlanMaxId OBJECT-TYPE SYNTAX INTEGER { maxId2000(2000), maxId4000(4000) } MAX-ACCESS read-only STATUS current DESCRIPTION "The maximum vlan Id that supported" DEFVAL { maxId2000 } ::= { rcSystem 69 } rcSysDnsDomainName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "Default domain used for querying the DNS Server." ::= { rcSystem 70 } rcSysDnsServerListIpAddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "DNS server's IP address " ::= { rcSystem 71 } rcSysDnsRequestType OBJECT-TYPE SYNTAX INTEGER { request (0), response (1) } MAX-ACCESS read-only STATUS current DESCRIPTION "DNS Type: Whether it was Dns Request or a Response" ::= { rcSystem 72 } rcSysSpanningTreeOperMode OBJECT-TYPE SYNTAX INTEGER { nortelStpg(1), pvst(2), rstp(3), mstp(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "This object indicates the current spanning-tree mode of the system. . The meaning of specific values is: nortelStpg(1) .. The older proprietary mode which supports multiple spanning tree groups. pvst(2) ........ Emulation of C***O spanning tree mode rstp(3) ........ IEEE 802.1w mode mstp(4) ........ IEEE 802.1s mode ." DEFVAL { nortelStpg } ::= { rcSystem 73} rcSysSpanningTreeAdminMode OBJECT-TYPE SYNTAX INTEGER { nortelStpg(1), pvst(2), rstp(3), mstp(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "This object indicates the desired spanning-tree mode of the system. The meaning of specific values is: nortelStpg(1) .. The older proprietary mode which supports multiple spanning tree groups. pvst(2) ........ Emulation of C***O spanning tree mode rstp(3) ........ IEEE 802.1w mode mstp(4) ........ IEEE 802.1s mode Note that depending on the current value of rcSysSpanningTreeOperMode and the value to which this object is set, the operational mode may be immediately changed, or the change may not take effect until the next system reboot." DEFVAL { nortelStpg } ::= { rcSystem 74} rcSysAutoRecoverDelay OBJECT-TYPE SYNTAX INTEGER (5..3600) MAX-ACCESS read-write STATUS current DESCRIPTION "Time interval in seconds after which auto-recovery runs on ports to clear action taken by cp-limit, link flap or loop detect" ::= { rcSystem 75 } rcSysMacFlapLimitTime OBJECT-TYPE SYNTAX INTEGER (10..5000) MAX-ACCESS read-write STATUS current DESCRIPTION "Time limit in milliseconds for MAC flapping for loop-detect feature" ::= { rcSystem 76 } rcSysMacFlapLimitCount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of times mac flapping can happen for loop-detect feature" ::= { rcSystem 77 } rcSysExtCplimitEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "enable or disable extended CP-LIMIT in system." DEFVAL { false } ::= { rcSystem 78 } rcSysExtCplimitMinCongTime OBJECT-TYPE SYNTAX INTEGER (100..6000) MAX-ACCESS read-write STATUS current DESCRIPTION "Minimum time for which System octapid should be congested to trigger congestion algorithm for extended CP-LIMIT in mSecs" DEFVAL { 3000 } ::= { rcSystem 79 } rcSysExtCplimitMaxPorts OBJECT-TYPE SYNTAX INTEGER (0..512) MAX-ACCESS read-write STATUS current DESCRIPTION "Maximum number of ports which need to be monitored for congestion in Extended CP-LIMIT" DEFVAL { 0 } ::= { rcSystem 80 } rcSysExtCplimitPortCongTime OBJECT-TYPE SYNTAX INTEGER (1..600) MAX-ACCESS read-write STATUS current DESCRIPTION "Minimum time for which ingress traffic utilization rate of a monitored port should stay more than the allowed limits in order to disable the port for extended CP-LIMIT in Secs" DEFVAL { 300 } ::= { rcSystem 81 } rcSysExtCplimitTrapLevel OBJECT-TYPE SYNTAX INTEGER { none(1), normal(2), verbose(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Indicates the trap level for extended CP-LIMIT" DEFVAL { none } ::= { rcSystem 82 } rcSysExtCplimitSysOctapidCongested OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether system octapid congestion detected for extended cp-limit" DEFVAL { false } ::= {rcSystem 83 } rcSysExtCplimitPortsMonitored OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether ports has been shutdown due to extended cp-limit" DEFVAL { false } ::= {rcSystem 84 } rcSysExtCplimitPortsShutDown OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Indicates whether ports has been shutdown due to extended Cp-limit" DEFVAL { false } ::= {rcSystem 85 } rcSysActionL1 OBJECT-TYPE SYNTAX INTEGER { none(1), resetCounters(2), -- reset all statistic counters saveToNVRAM(3), saveToStandbyNVRAM(4), -- save config to slave NVRAM checkSwInFlash(5), checkSwInPcmcia(6), saveRuntimeConfig(7), -- 8k only saveRuntimeConfigToSlave(8), -- 8k only saveBootConfig(9), -- 8k only saveSlaveBootConfig(10) -- 8k only } MAX-ACCESS read-write STATUS current DESCRIPTION "Initiate a system action for layer1 user" DEFVAL { none } ::= { rcSystem 86 } rcSysActionL2 OBJECT-TYPE SYNTAX INTEGER { none(1), resetIstStatCounters(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Initiate a system action for layer2 user" DEFVAL { none } ::= { rcSystem 87 } rcSysActionL3 OBJECT-TYPE SYNTAX INTEGER { none(1), flushIpRouteTbl(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Initiate a system action for layer2 user" DEFVAL { none } ::= { rcSystem 88 } rcSysActionRwa OBJECT-TYPE SYNTAX INTEGER { none(1), -- none of the following hardReset(2), -- power on tests softReset(3), -- reset w/o power on tests cpuSwitchOver(4), -- CPU board switch-over resetConsole(5), resetModem(6) -- being used in rel2.2(7) -- being used in rel2.2(8) -- reserve(9) -- reserve(10) } MAX-ACCESS read-write STATUS current DESCRIPTION "Initiate a system action." DEFVAL { none } ::= { rcSystem 89 } rcSysPowerUsage OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The current power usage for the whole chassis." ::= { rcSystem 90 } rcSysPowerAvailable OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The current power available for the whole chassis." ::= { rcSystem 91 } rcSysBpduStartMacAddress OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Starting Multicast MAC address for BPDUs" ::= { rcSystem 92 } rcSysBpduMacAddressMask OBJECT-TYPE SYNTAX INTEGER (1..48) MAX-ACCESS read-write STATUS current DESCRIPTION "BPDU MAC address Mask" ::= { rcSystem 93 } rcSysFrcMsgControlTable OBJECT-TYPE SYNTAX SEQUENCE OF RcSysFrcMsgControlEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Management Force-msg Control table. This table is used to specify the pattern for Force-msg Control" ::= { rcSystem 94 } rcSysFrcMsgControlEntry OBJECT-TYPE SYNTAX RcSysFrcMsgControlEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A Force-msg Control table entry." INDEX { rcSysFrcMsgControlPatternId } ::= { rcSysFrcMsgControlTable 1 } RcSysFrcMsgControlEntry ::= SEQUENCE { rcSysFrcMsgControlPatternId Integer32, rcSysFrcMsgControlPattern DisplayString, rcSysFrcMsgControlRowStatus RowStatus } rcSysFrcMsgControlPatternId OBJECT-TYPE SYNTAX Integer32 (1..32) MAX-ACCESS not-accessible STATUS current DESCRIPTION "Pattern Id." ::= { rcSysFrcMsgControlEntry 1 } rcSysFrcMsgControlPattern OBJECT-TYPE SYNTAX DisplayString (SIZE (4)) MAX-ACCESS read-write STATUS current DESCRIPTION "Pattern for filtering the force-msg for msg control" ::= { rcSysFrcMsgControlEntry 2 } rcSysFrcMsgControlRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-write STATUS current DESCRIPTION "Used to create/delete an entry" ::= { rcSysFrcMsgControlEntry 3 } rcSysAccPolSnmpGrpTable OBJECT-TYPE SYNTAX SEQUENCE OF RcSysAccPolSnmpGrpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "SNMP group list for access policy" ::= { rcSystem 95 } rcSysAccPolSnmpGrpEntry OBJECT-TYPE SYNTAX RcSysAccPolSnmpGrpEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "The table entry which covers the groups under snmp service." INDEX { rcSysAccessPolicyId, rcSysAccPolSnmpGrpName, rcSysAccPolSnmpGrpModel} ::= { rcSysAccPolSnmpGrpTable 1 } RcSysAccPolSnmpGrpEntry ::= SEQUENCE { rcSysAccPolSnmpGrpName SnmpAdminString, rcSysAccPolSnmpGrpModel SnmpSecurityModel, rcSysAccPolSnmpGrpRowStatus RowStatus } rcSysAccPolSnmpGrpName OBJECT-TYPE SYNTAX SnmpAdminString (SIZE(1..32)) MAX-ACCESS not-accessible STATUS current DESCRIPTION "The snmp-v3 group name" ::= { rcSysAccPolSnmpGrpEntry 1 } rcSysAccPolSnmpGrpModel OBJECT-TYPE SYNTAX SnmpSecurityModel MAX-ACCESS not-accessible STATUS current DESCRIPTION "The snmp model" ::= { rcSysAccPolSnmpGrpEntry 2 } rcSysAccPolSnmpGrpRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-write STATUS current DESCRIPTION "Row status" ::= { rcSysAccPolSnmpGrpEntry 3 } rcSysVirtualIpv6Addr OBJECT-TYPE SYNTAX Ipv6Address MAX-ACCESS read-write STATUS current DESCRIPTION "The virtual ipv6 address that is owned, advertised, and registered by the master CPU only. Unlike the net management IP address this address is configured in the switch config file as opposed to the boot config." ::= { rcSystem 96 } rcSysVirtualIpv6PrefixLength OBJECT-TYPE SYNTAX INTEGER (0..128) MAX-ACCESS read-write STATUS current DESCRIPTION "The length of the virtual ipv6 addr prefix (in bits)." ::= { rcSystem 97 } -- TFTP Upload/Download rcTftpHost OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Name of source/destination host for the TFTP transfer." ::= { rcTftp 1 } rcTftpFile OBJECT-TYPE SYNTAX DisplayString (SIZE (0..255)) MAX-ACCESS read-write STATUS current DESCRIPTION "Name of file for the TFTP transfer." ::= { rcTftp 2 } rcTftpAction OBJECT-TYPE SYNTAX INTEGER { none(1), -- none of the following downloadConfig(2), uploadConfig(3), downloadSwToFlash(4), downloadSwToPcmcia(5), uploadSw(6), downloadSwToDram(7) } MAX-ACCESS read-write STATUS current DESCRIPTION "The action for the TFTP transfer." DEFVAL { none } ::= { rcTftp 3 } rcTftpResult OBJECT-TYPE SYNTAX INTEGER { none(1), inProgress(2), noResponse(3), fileAccessError(4), badFlash(5), flashEraseFailed(6), pcmciaEraseFailed(7), success(8), fail(9), writeToNvramFailed(10), flashWriteFailed(11), pcmciaWriteFailed(12), configFileTooBig(13), imageFileTooBig(14), noPcmciaDetect(15), pcmciaNotSupported(16), invalidFile(17), noMemory(18), xferError(19), crcError(20), readNvramFailed(21), pcmciaWriteProtect(22) } MAX-ACCESS read-only STATUS current DESCRIPTION "Contains result of the last Tftp action request." ::= { rcTftp 4 } -- PHYSICAL Elements rcChasType OBJECT-TYPE SYNTAX INTEGER { unknown(1), -- unknown chassis a1100(2), -- 3 slot chassis (1/2, 1/2, full) a1250(6), -- 4 slot chassis (full, ... , full) a1150(7), -- 3 slot chassis (1/2, 1/2, full) a1200(8), -- 8 slot chassis (full, ... , full) a1050(9), -- 2 slot chassis (seahawk) a8006(280887558), -- 6 slot chassis (raptillion) a8010(280887562), -- 10 slot chassis (raptillion) a8010co(1623064842), -- 10 slot Central Office Chassis a8003(280887555), -- 3 slot chassis (raptillion) a1612G(1086197761), -- 1 slot 12 port cobra (0x40be1001) a1624G(1086201857), -- 1 slot 24 port cobra (0x40be2001) a1648T(1086210049), -- 1 slot 52 port cobra (0x40be4001) a8306(1354629382), -- 6 slot 8300 POE chassis (0x50be0106) a8310(1354629386) -- 10 slot 8300 POE chassis (0x50be010a) } MAX-ACCESS read-only STATUS current DESCRIPTION "Chassis Type" ::= { rcChassis 1 } rcChasSerialNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (0..16)) MAX-ACCESS read-only STATUS current DESCRIPTION "Unique serial number for this chassis." ::= { rcChassis 2 } rcChasHardwareRevision OBJECT-TYPE SYNTAX DisplayString (SIZE (0..20)) MAX-ACCESS read-only STATUS current DESCRIPTION "Device hardware revision level" ::= { rcChassis 3 } rcChasNumSlots OBJECT-TYPE SYNTAX INTEGER (1..16) MAX-ACCESS read-only STATUS current DESCRIPTION "The number of slots in the chassis available for plug-in cards." ::= { rcChassis 4 } rcChasNumPorts OBJECT-TYPE SYNTAX INTEGER (0..255) MAX-ACCESS read-only STATUS current DESCRIPTION "The total number of ports currently installed in the chassis." ::= { rcChassis 5 } -- TBD FIXME : We need to get the final list from Hardware rcChasTestResult OBJECT-TYPE SYNTAX INTEGER { other(1), ok(2), crceeprom(3), timer(4), procdram(5), led(6), formaccpuaccess(7), asiccpuaccess(8), memory(9), loopback(10) } MAX-ACCESS read-only STATUS current DESCRIPTION "Chassis start-up diagnostic tests." ::= { rcChassis 6 } rcChasFan OBJECT IDENTIFIER ::= { rcChassis 7 } rcChasFanTable OBJECT-TYPE SYNTAX SEQUENCE OF RcChasFanEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains information about Fans" ::= { rcChasFan 1 } rcChasFanEntry OBJECT-TYPE SYNTAX RcChasFanEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Contains information regarding a Fan Unit" INDEX { rcChasFanId } ::= { rcChasFanTable 1 } RcChasFanEntry ::= SEQUENCE { rcChasFanId INTEGER, rcChasFanOperStatus INTEGER, rcChasFanAmbientTemperature Gauge32 } rcChasFanId OBJECT-TYPE SYNTAX INTEGER(1..4) MAX-ACCESS read-only STATUS current DESCRIPTION "The chassis fan Id." ::= { rcChasFanEntry 1 } rcChasFanOperStatus OBJECT-TYPE SYNTAX INTEGER { unknown(1), up(2), down(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "Actual status of the Fan: - unknown(1) - status can not be determined. - up(2) - present and supplying power. - down(3) - present, but failure indicated." ::= { rcChasFanEntry 2 } rcChasFanAmbientTemperature OBJECT-TYPE SYNTAX Gauge32 MAX-ACCESS read-only STATUS current DESCRIPTION "Used to indicate the temperature of the air entering the fan." ::= { rcChasFanEntry 3 } rcChasPowerSupply OBJECT IDENTIFIER ::= { rcChassis 8 } rcChasPowerSupplyTable OBJECT-TYPE SYNTAX SEQUENCE OF RcChasPowerSupplyEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains information about power supplies." ::= { rcChasPowerSupply 1 } rcChasPowerSupplyEntry OBJECT-TYPE SYNTAX RcChasPowerSupplyEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Contains information regarding a power supply unit." INDEX { rcChasPowerSupplyId } ::= { rcChasPowerSupplyTable 1 } RcChasPowerSupplyEntry ::= SEQUENCE { rcChasPowerSupplyId INTEGER, rcChasPowerSupplyOperStatus INTEGER } rcChasPowerSupplyId OBJECT-TYPE SYNTAX INTEGER(1..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The power supply Id." ::= { rcChasPowerSupplyEntry 1 } rcChasPowerSupplyOperStatus OBJECT-TYPE SYNTAX INTEGER { unknown(1), empty(2), up(3), down(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "Actual status of the power supply: - unknown(1) - status can not be determined. - empty(2) - power supply not installed. - up(3) - present and supplying power. - down(4) - present, but failure indicated." ::= { rcChasPowerSupplyEntry 2 } rcChasPowerSupplyDetailTable OBJECT-TYPE SYNTAX SEQUENCE OF RcChasPowerSupplyDetailEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table contains detailed information about power supplies." ::= { rcChasPowerSupply 2 } rcChasPowerSupplyDetailEntry OBJECT-TYPE SYNTAX RcChasPowerSupplyDetailEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Contains detailed info regarding a power supply unit." INDEX { rcChasPowerSupplyDetailId } ::= { rcChasPowerSupplyDetailTable 1 } RcChasPowerSupplyDetailEntry ::= SEQUENCE { rcChasPowerSupplyDetailId INTEGER, rcChasPowerSupplyDetailType INTEGER, rcChasPowerSupplyDetailSerialNumber DisplayString, rcChasPowerSupplyDetailHardwareRevision DisplayString, rcChasPowerSupplyDetailPartNumber DisplayString, rcChasPowerSupplyDetailDescription DisplayString, rcChasPowerSupplyDetailPsePower INTEGER } rcChasPowerSupplyDetailId OBJECT-TYPE SYNTAX INTEGER(1..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The power supply Id." ::= { rcChasPowerSupplyDetailEntry 1 } rcChasPowerSupplyDetailType OBJECT-TYPE SYNTAX INTEGER { unknown(0), ac(1), dc(2), poe(278798592) , -- 8300 110/200 V AC/DC PoE(0x109e2100) poe1400WPS(278802688) -- 8300 110/200 V 850W/1400W AC/DC PoE(0x109e3100) } MAX-ACCESS read-only STATUS current DESCRIPTION "The power supply type." ::= { rcChasPowerSupplyDetailEntry 2 } rcChasPowerSupplyDetailSerialNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (0..16)) MAX-ACCESS read-only STATUS current DESCRIPTION "The power supply serial number." ::= { rcChasPowerSupplyDetailEntry 3 } rcChasPowerSupplyDetailHardwareRevision OBJECT-TYPE SYNTAX DisplayString (SIZE (0..16)) MAX-ACCESS read-only STATUS current DESCRIPTION "The hardware revision of the power supply." ::= { rcChasPowerSupplyDetailEntry 4 } rcChasPowerSupplyDetailPartNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (0..16)) MAX-ACCESS read-only STATUS current DESCRIPTION "The power supply part number." ::= { rcChasPowerSupplyDetailEntry 5 } rcChasPowerSupplyDetailDescription OBJECT-TYPE SYNTAX DisplayString (SIZE (0..64)) MAX-ACCESS read-only STATUS current DESCRIPTION "The detail description of power supply." ::= { rcChasPowerSupplyDetailEntry 6 } rcChasPowerSupplyDetailPsePower OBJECT-TYPE SYNTAX INTEGER (1..65535) MAX-ACCESS read-only STATUS current DESCRIPTION "The nominal power of the PSE expressed in Watts." ::= { rcChasPowerSupplyDetailEntry 7 } rcCard OBJECT IDENTIFIER ::= { rcChassis 9 } rcCardTable OBJECT-TYPE SYNTAX SEQUENCE OF RcCardEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "A table that contains information about the cards in this chassis. For those slots that do not contain a physical card, the table may be implemented to contain a conceptual row with the type of physical module set to 'chasCardEmpty', or it may be implemented to have no conceptual row instance." ::= { rcCard 1 } rcCardEntry OBJECT-TYPE SYNTAX RcCardEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Card attributes" INDEX { rcCardIndex } ::= { rcCardTable 1 } RcCardEntry ::= SEQUENCE { rcCardIndex INTEGER, rcCardType INTEGER, rcCardSerialNumber DisplayString, rcCardHardwareRevision DisplayString, rcCardAdminStatus INTEGER, rcCardOperStatus INTEGER, rcCardPCMCIAType INTEGER, rcCardPartNumber DisplayString } rcCardIndex OBJECT-TYPE SYNTAX INTEGER (1..10) MAX-ACCESS read-only STATUS current DESCRIPTION "A unique value for each module within the chassis. This value is determined by the chassis slot number where the module is inserted. Valid entries are 1 to the value of rcChasNumSlots" ::= { rcCardEntry 1 } rcCardType OBJECT-TYPE SYNTAX INTEGER { other(1), -- no card installed rcCPU(2), -- [1200] CPU Card (A1200) rc8x100BaseTX(3), -- [1208TX] 8 port (cat 5) (A1200) rc8x100BaseT2(4), -- [] 8 port (cat 3) (A1200) rc8x100BaseF(5), -- [1208FX] 8 port fiber (A1200) rc16x100BaseTX(6), -- [1216TX] 16 port (cat 5) (A1200) rc8x100BaseTXWG(12), -- [1108TX] 8 port (half width) (A1100) rc16x100BaseTXWG(13), -- [1100] 16 port + CPU (A1100) rc4x100BaseFWG(14), -- [1104FX] 4 port (half width) (A1100) rc12x100BaseTXWG(15), -- [1050] 12 port + CPU (A1050) rc12x100BaseFBB(16), -- [] 12 port (A1200) rc8x100BaseFWG(17), -- [1108FX] 8 port (A1100) rc12x100BaseTX-2x100BaseFBB(18), -- [] 12 port + 2 port (A1200) rc2x155BaseFBB(19), -- [] 2 sonet port (A1200) rc4x155BaseFBB(20), -- [] 4 sonet port (A1200) rc16x100BaseFBB(21), -- [1216FX] 16 port fiber (A1200) rc14x100BaseTX-2x100BaseFBB(22), -- [1216TF] 14 port + 2 port (A1200) rc8x10BaseFBB(23), -- [1208FL] 8 port fiber low-speed (A1200) rc4xOC3(24), -- [1200xx] 4 port OC3 (A1200) rc1xOC12(25), -- [1200xx] 1 port OC12 (A1200) rcRMON(26), -- [1200xx] RMON (A1200) rc1xOC12POSBaseMMF(27), -- [1200xx] 1 port OC12 POS (A1200) rc1xOC12POSBaseSMF(28), -- [1200xx] 1 port OC12 POS (A1200) rc4x1000BaseSXWG(1028), -- [1150] 1 0 00 000 0100 + CPU (A1150) rc1x1000BaseSXWG(1025), -- [1101SX] 1 0 00 000 0001 rc2x1000BaseSXWG(1026), -- [1102SX] 1 0 00 000 0010 rc1x1000BaseSXRWG(1537), -- [1101SR] 1 1 00 000 0001 rc2x1000BaseSXRWG(1538), -- [1102SR] 1 1 00 000 0010 rc1x1000BaseLXWG(1153), -- [1101LX] 1 0 01 000 0001 rc2x1000BaseLXWG(1154), -- [1102LX] 1 0 01 000 0010 rc2x1000BaseXDWG(1282), -- [1102XD] 1 0 10 000 0010 rc1x1000BaseLXRWG(1665), -- [1101LR] 1 1 01 000 0001 rc2x1000BaseLXRWG(1666), -- [1102LR] 1 1 01 000 0010 rc1x1000BaseSXBB(1041), -- [1201SX] 1 0 00 001 0001 rc2x1000BaseSXBB(1042), -- [1202SX] 1 0 00 001 0010 rc1x1000BaseSXRBB(1553), -- [1201SR] 1 1 00 001 0001 rc2x1000BaseSXRBB(1554), -- [1202SR] 1 1 00 001 0010 rc1x1000BaseLXBB(1169), -- [1201LX] 1 0 01 001 0001 rc2x1000BaseLXBB(1170), -- [1202LX] 1 0 01 001 0010 rc2x1000BaseXDBB(1298), -- [1202XD] 1 0 10 001 0010 rc1x1000BaseLXRBB(1681), -- [1201LR] 1 1 01 001 0001 rc2x1000BaseLXRBB(1682) -- [1202LR] 1 1 01 001 0010 } MAX-ACCESS read-only STATUS current DESCRIPTION "Used to indicate a card types in the Accelar 1000 product families. For Accelar 1000 devices, gigabit cards use an encoded value according to the following rule: +-----+--+-+---+---+---+ bits : |31-11|10|9|8-7|6-4|3-0| +-----+--+-+---+---+---+ field : | a | b|c| d | e | f | +-----+--+-+---+---+---+ a : not-used b : 1=gigabit c : 0=non-redundant, 1=redundant d : 0=short-haul, 1=long-haul, 2=extra-distance, e : 0=work-group(a1100 and a1150) 1=back-bone(a1200, f1250, and f2000), f : 1=1-port, 2=2-port, 4=4-port, 8=8-port " ::= { rcCardEntry 2 } rcCardSerialNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (0..16)) MAX-ACCESS read-only STATUS current DESCRIPTION "Unique serial number for this card." ::= { rcCardEntry 3 } rcCardHardwareRevision OBJECT-TYPE SYNTAX DisplayString (SIZE (0..8)) MAX-ACCESS read-only STATUS current DESCRIPTION "Hardware Version" ::= { rcCardEntry 4 } rcCardAdminStatus OBJECT-TYPE SYNTAX INTEGER { up(1), down(2), testing(3) } MAX-ACCESS read-write STATUS current DESCRIPTION "Used to indicate the administrative status of this card" ::= { rcCardEntry 5 } rcCardOperStatus OBJECT-TYPE SYNTAX INTEGER { up(1), down(2), testing(3), unknown(4), dormant(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "Used to indicate the operational status of this card." ::= { rcCardEntry 6 } rcCardPCMCIAType OBJECT-TYPE SYNTAX INTEGER { none(1), modem28kbs(2), flash2meg(3), flash4meg(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "Used to indicate the type of PCMCIA card currently installed in this CPU card, if any. For non-CPU cards, this variable has no meaning and will always be set to none." DEFVAL { none } ::= { rcCardEntry 7 } rcCardPartNumber OBJECT-TYPE SYNTAX DisplayString (SIZE (0..6)) MAX-ACCESS read-only STATUS current DESCRIPTION "Card Part Number" ::= { rcCardEntry 8 } rcPort OBJECT IDENTIFIER ::= { rcChassis 10 } -- defined in rcPortXXX.mib -- Additional Chassis Group Variables rcChasAruMode OBJECT-TYPE SYNTAX INTEGER { aruOne(1), aruTwo(2), aruThree(3) } MAX-ACCESS read-only STATUS current DESCRIPTION "The ARU mode the chassis is operating in." ::= { rcChassis 12 } rcChasQuidMode OBJECT-TYPE SYNTAX INTEGER { quidMixed(1), quidTwo(2), quidThree(3), quidFour(4), quidFive(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "The Quid mode the chassis is operating in." ::= { rcChassis 13 } rcChasEocModeAdminStatus OBJECT-TYPE SYNTAX INTEGER { default(0), aru1Quid4(1), aru2Quid4(2), aru2Quid5(3), aru3Quid4(4), aru3Quid5(5) } MAX-ACCESS read-write STATUS current DESCRIPTION "Used to specify the Enforce Operational Configuration Mode(EOC) of the system. When a device is configured with hardware of different revisions, the system will initialize in some deterministic manner (e.g., the lowest common denominator that makes sense based on the hardware configuration). This is the 'default(0)' mode. The user can override this behavior by manually specifying the EOC Mode they would like." ::= { rcChassis 14 } -- Agent Table rcAgentTable OBJECT-TYPE SYNTAX SEQUENCE OF RcAgentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Agents in a chassis table" ::= { rcChassis 16 } rcAgentEntry OBJECT-TYPE SYNTAX RcAgentEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry containing info. for a particular agent" INDEX { rcAgentId } ::= { rcAgentTable 1 } RcAgentEntry ::= SEQUENCE { rcAgentId Integer32, rcAgentSlot Integer32, rcAgentIpAddr IpAddress } rcAgentId OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "entry id" ::= { rcAgentEntry 1 } rcAgentSlot OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "slot agent is in." ::= { rcAgentEntry 2 } rcAgentIpAddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "agent's ip address." ::= { rcAgentEntry 3 } rcChasEocModeOperStatus OBJECT-TYPE SYNTAX INTEGER { default(0), aru1Quid4(1), aru2Quid4(2), aru2Quid5(3), aru3Quid4(4), aru3Quid5(5) } MAX-ACCESS read-only STATUS current DESCRIPTION "Used to indicate the Enforce Operational Configuration Mode(EOC) of the system." ::= { rcChassis 15 } rcChasBrouterPorts OBJECT-TYPE SYNTAX PortSet MAX-ACCESS read-only STATUS current DESCRIPTION "Used to indicate which ports in the system are configured as Brouter ports." ::= { rcChassis 17 } rcChasGlobalFilterEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Used to enable/disable global filters in the system. This variable is currently not supported." DEFVAL { false } ::= { rcChassis 18 } rcChasVlanBySrcMacEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Used to enable/disable source MAC based VLANs in the system." DEFVAL { false } ::= { rcChassis 19 } rcChasDiffServEcnCompatibilityEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Used to enable/disable the Explicit Congestion Notification(ECN) compatibility feature. When set to FALSE , the system will mask the ECN bits in the DS field while re-marking DSCP and will not match on ECN capable flows if filter is set on DSmatch. When set to TRUE, it will preserve the ECN bits in the DS field while re-marking and will match on full 8-bit DS field." DEFVAL { false } ::= { rcChassis 20 } rcChasNewEnhancedOperMode OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Enhanced operational mode." ::= { rcChassis 21 } rcChasNewEMMode OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This configuration is for enabling/disabling 128K mode. The change will take effect upon reboot." ::= { rcChassis 22 } rcChasEmModeError OBJECT-TYPE SYNTAX INTEGER { none(1), non128KCardOffLine(2), checkSlaveConfigNResetForEmMMode(3), mismatchResetForEmMode(4), mismatchEmModeMasterSlave(5), incompatMasterResetForEmMode(6), putSlaveOffEmImcompat(7), slave8690EmIncompatGoingOffline(8), cpu8690DisableEm(9) } MAX-ACCESS read-only STATUS current DESCRIPTION "Used to indicate the Em-mode error status" ::= { rcChassis 23 } rcChasEnhancedOperMode OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Enhanced Operational mode the switch currently has booted and will remain the same unitl the next reboot." ::= { rcChassis 24 } rcChasEMMode OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "EM mode the switch currently has booted and will remain the same unitl the next reboot." ::= { rcChassis 25 } rcChasFtpDaemonInSecondaryCpu OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Used to enable/disable FTP daemon in 2nd cpu." DEFVAL { false } ::= { rcChassis 26 } rcChasSmltOnSingleCpEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Enable SMLT on single CP feature in the switch" ::= { rcChassis 27 } rcChasNewVlanOptmMode OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Vlan Optimization mode." ::= { rcChassis 28 } rcChasVlanOptmMode OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "Vlan Optimization mode the switch currently has booted and will remain the same unitl the next reboot." ::= { rcChassis 29 } -- defined in rcLaunchPadXXX.mib rcLaunchPad OBJECT IDENTIFIER ::= { rcChassis 30 } rcChasNaapEnable OBJECT-TYPE SYNTAX EnableValue MAX-ACCESS read-write STATUS current DESCRIPTION "To enable/disbale to napp feature." ::= { rcChassis 31 } rcChasGlobalFilterOrderingEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Used to enable/disable global filter ordering in the system." DEFVAL { false } ::= { rcChassis 32 } rcChasNewGlobalFilterOrderingEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This configuration is for enabling/disabling global filter ordering. The change will take effect upon reboot." DEFVAL { false } ::= { rcChassis 33 } rcChasWsmDirectMode OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This is for enabling/disabling configuration of same community strings on the WSM and 8600. This if for allowing users to connect directly via SNMP to the WSM blade." DEFVAL { false } ::= { rcChassis 34 } rcChasRspMode OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "This configuration is for enabling/disabling 256K mode. The change will take effect upon reboot." ::= { rcChassis 35 } rcChasRspOperMode OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS current DESCRIPTION "R-mode the switch currently has booted and will remain the same until the next reboot." ::= { rcChassis 36 } rcChasRspModeError OBJECT-TYPE SYNTAX INTEGER { none(1), non256KCardOffLine(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Used to indicate the r-mode error status" ::= { rcChassis 37 } rcChasPOE OBJECT IDENTIFIER ::= { rcChassis 38 } rcChasPOEPower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total PoE power which this chassis supports (Unit in Watts)." ::= { rcChasPOE 1 } rcChasPOEAllocatedPower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total PoE power allocated for PoE modules installed in this chassis (Unit in Watts)." ::= { rcChasPOE 2 } rcChasPOEAvailablePower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total PoE power available for any additional PoE power request or allocation (Unit in Watts)." ::= { rcChasPOE 3 } rcChasPOEBackUpPower OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The total PoE power reserved for backup or redundancy (Unit in Watts)." ::= { rcChasPOE 4 } -- rcRepeater rcRepeater OBJECT IDENTIFIER ::= { rcChassis 39 } rcRepeaterTable OBJECT-TYPE SYNTAX SEQUENCE OF RcRepeaterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Port repeater table" ::= { rcRepeater 1 } rcRepeaterEntry OBJECT-TYPE SYNTAX RcRepeaterEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry containing info. for a particular repeater" INDEX { rcRepeaterId } ::= { rcRepeaterTable 1 } RcRepeaterEntry ::= SEQUENCE { rcRepeaterId INTEGER, rcRepeaterFirstPort InterfaceIndex, rcRepeaterSecondPort InterfaceIndex, rcRepeaterVlanId INTEGER, rcRepeaterName DisplayString, rcRepeaterRowStatus RowStatus } rcRepeaterId OBJECT-TYPE SYNTAX INTEGER(1..32) MAX-ACCESS read-only STATUS current DESCRIPTION "A value that uniquely identifies the repeater." ::= { rcRepeaterEntry 1 } rcRepeaterFirstPort OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-write STATUS current DESCRIPTION "First port member of the Repeater" ::= { rcRepeaterEntry 2 } rcRepeaterSecondPort OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-write STATUS current DESCRIPTION "Second port member of the Repeater" ::= { rcRepeaterEntry 3 } rcRepeaterVlanId OBJECT-TYPE SYNTAX INTEGER (0..4094) MAX-ACCESS read-write STATUS current DESCRIPTION "A value that uniquely identifies the Virtual LAN associated with first port" ::= { rcRepeaterEntry 4 } rcRepeaterName OBJECT-TYPE SYNTAX DisplayString (SIZE (0..20)) MAX-ACCESS read-write STATUS current DESCRIPTION "An administratively-assigned name for this repeater." ::= { rcRepeaterEntry 5 } rcRepeaterRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-write STATUS current DESCRIPTION "Used to create/delete entries in the rcRepeater." ::= { rcRepeaterEntry 6 } rcChasMcastCheckPktEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Used to enable/disable Multicast check packet in the system. This change will take effect upon reboot. " DEFVAL { true } ::= { rcChassis 40 } rcChasSystemMonitorEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Enable/Disable System monitoring in the switch" DEFVAL { true } ::= { rcChassis 41 } -- Dip-Switch Group rcIsolateUnconfigPorts OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Used to indicate whether ports that are unconfigured should be assigned to the 'isolated' VLAN. Ports assigned to the 'isolated' VLAN can only communicate with the CP port. If this option is not specified, unconfigured ports will be assigned to the 'default' VLAN" ::= { rcDipSwitch 1 } rcUseFactorySettings OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Used to indicate whether the system should ignore the configuration information stored in NVRAM when the system is booted." ::= { rcDipSwitch 2 } rcHighPriorityMode OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Used to indicate whether the system is configured to operate in a high priority mode. The switch can operate in either a 'best effort' or 'high priority' mode. In the 'best effort' setting, the maximum queue thresholds for the QUIDs are set to 768/768 buffers. In the 'high priority' mode the setting is 512/768. This means that in 'high priority' mode the normal priority queue can't have more than 512 buffers, while the high priority queue can have up to 768." ::= { rcDipSwitch 3 } -- Table Size Group rcTblRmonStatSize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Used to indicate the current size of the RMON Statistic table." ::= { rcTblSize 1 } rcTblRmonHistoryControlSize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Used to indicate the current size of the RMON History Control table." ::= { rcTblSize 2 } rcTblRmonHistoryEnetSize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Used to indicate the current size of the RMON History Ethernet table." ::= { rcTblSize 3 } rcTblRmonAlarmSize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Used to indicate the current size of the RMON Alarm table." ::= { rcTblSize 4 } rcTblRmonEventSize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Used to indicate the current size of the RMON Event table." ::= { rcTblSize 5 } rcTblRmonLogSize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Used to indicate the current size of the RMON Log table." ::= { rcTblSize 6 } rcTblArTblSize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Used to indicate the size of the Address Translation (AR) table." ::= { rcTblSize 7 } rcTblArFree OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Used to indicate the number of free entries that are available in the Address Translation (AR) table." ::= { rcTblSize 8 } rcTblArNoSpace OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Used to indicate the number of entries that could not be added to the Address Translation (AR) table due to lack of space." ::= { rcTblSize 9 } rcTblArAdded OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Used to indicate the number of entries added to the Address Translation (AR) table." ::= { rcTblSize 10 } rcTblArDeleted OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Used to indicate the number of entries deleted to the Address Translation (AR) table." ::= { rcTblSize 11 } rcTblArMacAdded OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Used to indicate the number of MAC entries added to the Address Translation (AR) table." ::= { rcTblSize 12 } rcTblArMacDeleted OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Used to indicate the number of MAC entries deleted to the Address Translation (AR) table." ::= { rcTblSize 13 } rcTblArMacMoved OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Used to indicate the number of MAC entries moved in the Address Translation (AR) table." ::= { rcTblSize 14 } rcTblArIpAdded OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Used to indicate the number of IP entries added to the Address Translation (AR) table." ::= { rcTblSize 15 } rcTblArIpDeleted OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Used to indicate the number of IP entries deleted to the Address Translation (AR) table." ::= { rcTblSize 16 } rcTblArMcastTblSize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Used to indicate the size of the Multicast Address Translation (AR) table." ::= { rcTblSize 17 } rcTblArFreeMcastGroups OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Used to indicate the number of free multicast groups availabe in the Address Translation (AR) table." ::= { rcTblSize 18 } rcTblArIpMcastAdded OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Used to indicate the number of Ip multicast entries that are added to the Address Translation (AR) table." ::= { rcTblSize 19 } rcTblArIpMcastDeleted OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Used to indicate the number of Ip multicast entries that are deleted from the Address Translation (AR) table." ::= { rcTblSize 20 } rcTblArVlanByPortAdded OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Used to indicate the number of VLAN by port entries that are added to the Address Translation (AR) table." ::= { rcTblSize 21 } rcTblArVlanByPortDeleted OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Used to indicate the number of VLAN by port entries that are deleted from the Address Translation (AR) table." ::= { rcTblSize 22 } rcTblArVlanByProtocolAdded OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Used to indicate the number of Vlans by Protocol Type entries that are added to the Address Translation (AR) table." ::= { rcTblSize 23 } rcTblArVlanByProtocolDeleted OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Used to indicate the number of Vlans by Protocol Type entries that are deleted from the Address Translation (AR) table." ::= { rcTblSize 24 } rcTblArVlanByIpSubnetAdded OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Used to indicate the number of VLAN by Ip entries that are added to the Address Translation (AR) table." ::= { rcTblSize 25 } rcTblArVlanByIpSubnetDeleted OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Used to indicate the number of VLAN by Ip entries that are deleted from the Address Translation (AR) table." ::= { rcTblSize 26 } rcTblArIpSubnetsAdded OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Used to indicate the number of Ip subnet entries that are added to the Address Translation (AR) table." ::= { rcTblSize 27 } rcTblArIpSubnetsDeleted OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Used to indicate the number of Ip subnet entries that are deleted from the Address Translation (AR) table." ::= { rcTblSize 28 } rcTblArRsvpsAdded OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Used to indicate the number of RSVP entries that are added to the Address Translation (AR) table." ::= { rcTblSize 29 } rcTblArRsvpsDeleted OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Used to indicate the number of RSVP entries that are deleted from the Address Translation (AR) table." ::= { rcTblSize 30 } rcTblBrdgFdbSize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Used to indicate the number of entries in the dot1d forwarding database table." ::= { rcTblSize 31 } rcTblBrdgStaticSize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Used to indicate the number of entries in the dot1d Static Address Filtering table." ::= { rcTblSize 32 } rcTblIpAddrSize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Used to indicate the number of entries in the IP Address table." ::= { rcTblSize 33 } rcTblIpForwardingSize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Used to indicate the number of entries in the IP Forwarding/Best Route table." ::= { rcTblSize 34 } rcTblIpNetToMediaSize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Used to indicate the number of entries in the IP Net-to-media table." ::= { rcTblSize 35 } rcTblIpBestPlusAltRouteSize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { rcTblSize 36 } rcTblIpBestPathSize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { rcTblSize 37 } rcTblIpBestPlusAltPathSize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "" ::= { rcTblSize 38 } -- rcBoot Group rcBootFlashSwVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS obsolete DESCRIPTION "BootFlashSwVersion indicates the software version in the Flash." ::= { rcBoot 1 } rcBootPcmciaSwVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS obsolete DESCRIPTION "BootPcmciaSwVersion indicate the software version in the Pcmcia card." ::= { rcBoot 2 } rcBootLastBootSource OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS obsolete DESCRIPTION "Indicates the boot source of the last the system boot." ::= { rcBoot 3 } rcBootPrimary OBJECT-TYPE SYNTAX INTEGER { flash(1), pcmcia(2), net(3), skip(4) } MAX-ACCESS read-write STATUS obsolete DESCRIPTION "BootPrimary is indicator for the primary source to boot the system." DEFVAL { flash } ::= { rcBoot 4 } rcBootSecondary OBJECT-TYPE SYNTAX INTEGER { flash(1), pcmcia(2), net(3), skip(4) } MAX-ACCESS read-write STATUS obsolete DESCRIPTION "BootSecondary indicates the second choice of the boot source." DEFVAL { pcmcia } ::= { rcBoot 5 } rcBootTertiary OBJECT-TYPE SYNTAX INTEGER { flash(1), pcmcia(2), net(3), skip(4) } MAX-ACCESS read-write STATUS obsolete DESCRIPTION "BootTertiary indicates the third choice of boot source." DEFVAL { net } ::= { rcBoot 6 } -- rcDevice Group rcDeviceLastBootSource OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Used to indicate the source of the software image the system was last booted with." ::= { rcDevice 1 } rcDevicePrimarySource OBJECT-TYPE SYNTAX INTEGER { flash(1), pcmcia(2), net(3), skip(4) } MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Used to indicate the primary choice to get a system software image." ::= { rcDevice 2 } rcDevicePrimarySourceFileName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..255)) MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Used to indicate a file number, if applicable." ::= { rcDevice 3 } rcDeviceSecondarySource OBJECT-TYPE SYNTAX INTEGER { flash(1), pcmcia(2), net(3), skip(4) } MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Used to indicate the secondary choice to get a system software image." ::= { rcDevice 4 } rcDeviceSecondarySourceFileName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..255)) MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Used to indicate a file name, if applicable." ::= { rcDevice 5 } rcDeviceTertiarySource OBJECT-TYPE SYNTAX INTEGER { flash(1), pcmcia(2), net(3), skip(4) } MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Used to indicate the tertiary choice to get a system software image." ::= { rcDevice 6 } rcDeviceTertiarySourceFileName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..255)) MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Used to indicate a file name, if applicable." ::= { rcDevice 7 } rcDeviceConfigSource OBJECT-TYPE SYNTAX INTEGER { flash(1), pcmcia(2), nvram(5) } MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Used to indicate the location to get a system configuration file during system boot." ::= { rcDevice 8 } rcDeviceConfigSourceFileName OBJECT-TYPE SYNTAX DisplayString (SIZE(0..255)) MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Used to indicate a file name, if applicable." ::= { rcDevice 9 } rcDeviceFlashBytesUsed OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Used to indicate the number of bytes used in the system's configuration flash device." ::= { rcDevice 10 } rcDeviceFlashBytesFree OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Used to indicate the number of bytes available in the system's configuration flash device." ::= { rcDevice 11 } rcDevicePcmciaBytesUsed OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Used to indicate the number of bytes used in the system's PCMCIA device." ::= { rcDevice 12 } rcDevicePcmciaBytesFree OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Used to indicate the number of bytes available in the system's PCMCIA device." ::= { rcDevice 13 } rcDeviceAction OBJECT-TYPE SYNTAX INTEGER { none(1), squeezeFlash(2), squeezePcmcia(3), formatFlash(4), formatPcmcia(5), recoverFlash(6), recoverPcmcia(7) } MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Used to specify a particular action to perform on one of the system's device." ::= { rcDevice 14 } rcDeviceResult OBJECT-TYPE SYNTAX INTEGER { none(1), inProgress(2), success(3), fail(4) } MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Used to indicate the result of the last action performed on one of the system's device." ::= { rcDevice 15 } rcDeviceFlashNumFiles OBJECT-TYPE SYNTAX INTEGER (0..128) MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Used to indicate the number of files available in the system's configuration flash device." ::= { rcDevice 16 } rcDevicePcmciaNumFiles OBJECT-TYPE SYNTAX INTEGER (0..128) MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Used to indicate the number of files available in the system's PCMCIA device." ::= { rcDevice 17 } -- The Device Flash Table rcDeviceFlashTable OBJECT-TYPE SYNTAX SEQUENCE OF RcDeviceFlashEntry MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION "Flash table." ::= { rcDevice 25 } rcDeviceFlashEntry OBJECT-TYPE SYNTAX RcDeviceFlashEntry MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION "An entry in the system's flash table." INDEX { rcDeviceFlashFileNum } ::= { rcDeviceFlashTable 1 } RcDeviceFlashEntry ::= SEQUENCE { rcDeviceFlashFileNum INTEGER, rcDeviceFlashFileName DisplayString, rcDeviceFlashFileVersion DisplayString, rcDeviceFlashFileType INTEGER, rcDeviceFlashFileMode INTEGER, rcDeviceFlashFileSize Integer32, rcDeviceFlashFileCrc Integer32, rcDeviceFlashFileStatus INTEGER, rcDeviceFlashRowStatus RowStatus } rcDeviceFlashFileNum OBJECT-TYPE SYNTAX INTEGER (0..128) MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Used to indicate a particular file in flash." ::= { rcDeviceFlashEntry 1 } rcDeviceFlashFileName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Used to indicate a flash file's name." ::= { rcDeviceFlashEntry 2 } rcDeviceFlashFileVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Used to indicate the flash file's version." ::= { rcDeviceFlashEntry 3 } rcDeviceFlashFileType OBJECT-TYPE SYNTAX INTEGER { config(1), log(2), trace(3), executable(4) } MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Used to indicate the flash file's type." ::= { rcDeviceFlashEntry 4 } rcDeviceFlashFileMode OBJECT-TYPE SYNTAX INTEGER { compressed(1), uncompressed(2) } MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Used to indicate the flash file's mode." ::= { rcDeviceFlashEntry 5 } rcDeviceFlashFileSize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Used to indicate the flash file's size." ::= { rcDeviceFlashEntry 6 } rcDeviceFlashFileCrc OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Used to indicate the flash file's CRC." ::= { rcDeviceFlashEntry 7 } rcDeviceFlashFileStatus OBJECT-TYPE SYNTAX INTEGER { active(1), deleted(2) } MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Used to indicate the flash file's status. A file that has been marked for deletion, but who's space has not been reclaimed yet is marked as 'deleted'." ::= { rcDeviceFlashEntry 8 } rcDeviceFlashRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Row status." ::= { rcDeviceFlashEntry 9 } -- The Device Pcmcia Table rcDevicePcmciaTable OBJECT-TYPE SYNTAX SEQUENCE OF RcDevicePcmciaEntry MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION "PCMCIA table." ::= { rcDevice 26 } rcDevicePcmciaEntry OBJECT-TYPE SYNTAX RcDevicePcmciaEntry MAX-ACCESS not-accessible STATUS deprecated DESCRIPTION "An entry in the system's PCMCIA table." INDEX { rcDevicePcmciaFileNum } ::= { rcDevicePcmciaTable 1 } RcDevicePcmciaEntry ::= SEQUENCE { rcDevicePcmciaFileNum INTEGER, rcDevicePcmciaFileName DisplayString, rcDevicePcmciaFileVersion DisplayString, rcDevicePcmciaFileType INTEGER, rcDevicePcmciaFileMode INTEGER, rcDevicePcmciaFileSize Integer32, rcDevicePcmciaFileCrc Integer32, rcDevicePcmciaFileStatus INTEGER, rcDevicePcmciaRowStatus RowStatus } rcDevicePcmciaFileNum OBJECT-TYPE SYNTAX INTEGER (0..128) MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Used to indicate a particular file in PCMCIA." ::= { rcDevicePcmciaEntry 1 } rcDevicePcmciaFileName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Used to indicate the PCMCIA file's name." ::= { rcDevicePcmciaEntry 2 } rcDevicePcmciaFileVersion OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Used to indicate the PCMCIA file's version." ::= { rcDevicePcmciaEntry 3 } rcDevicePcmciaFileType OBJECT-TYPE SYNTAX INTEGER { config(1), log(2), trace(3), executable(4) } MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Used to indicate the PCMCIA file's type." ::= { rcDevicePcmciaEntry 4 } rcDevicePcmciaFileMode OBJECT-TYPE SYNTAX INTEGER { compressed(1), uncompressed(2) } MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Used to indicate a particular file in mode." ::= { rcDevicePcmciaEntry 5 } rcDevicePcmciaFileSize OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Used to indicate the PCMCIA file's size." ::= { rcDevicePcmciaEntry 6 } rcDevicePcmciaFileCrc OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Used to indicate the PCMCIA file's CRC." ::= { rcDevicePcmciaEntry 7 } rcDevicePcmciaFileStatus OBJECT-TYPE SYNTAX INTEGER { active(1), deleted(2) } MAX-ACCESS read-only STATUS deprecated DESCRIPTION "Used to indicate the PCMCIA file's status. A file that has been marked for deletion, but who's space has not been reclaimed yet is marked as 'deleted'." ::= { rcDevicePcmciaEntry 8 } rcDevicePcmciaRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-write STATUS deprecated DESCRIPTION "Row status." ::= { rcDevicePcmciaEntry 9 } -- rcWeb related information rcWebEnableServer OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Control whether the web server should be enabled. Setting this variable to true will make the server operational. Setting this variable to false will disable server." DEFVAL { false } ::= { rcWeb 1 } rcWebRWAUserName OBJECT-TYPE SYNTAX DisplayString (SIZE (1..20)) MAX-ACCESS read-write STATUS current DESCRIPTION "User name for the read-write-all web-server account." ::= { rcWeb 2 } rcWebRWAPassword OBJECT-TYPE SYNTAX DisplayString (SIZE (1..20)) MAX-ACCESS read-write STATUS current DESCRIPTION "Password for the read-write-all web-server account." ::= { rcWeb 3 } rcWebRWUserName OBJECT-TYPE SYNTAX DisplayString (SIZE (1..20)) MAX-ACCESS read-write STATUS current DESCRIPTION "User name for the read-write web-server account." ::= { rcWeb 4 } rcWebRWPassword OBJECT-TYPE SYNTAX DisplayString (SIZE (1..20)) MAX-ACCESS read-write STATUS current DESCRIPTION "Password for the read-write web-server account." ::= { rcWeb 5 } rcWebROUserName OBJECT-TYPE SYNTAX DisplayString (SIZE (1..20)) MAX-ACCESS read-write STATUS current DESCRIPTION "User name for the read-only web-server account." ::= { rcWeb 6 } rcWebROPassword OBJECT-TYPE SYNTAX DisplayString (SIZE (1..20)) MAX-ACCESS read-write STATUS current DESCRIPTION "Password for the read-only web-server account." ::= { rcWeb 7 } rcWebLastChange OBJECT-TYPE SYNTAX TimeTicks MAX-ACCESS read-only STATUS current DESCRIPTION "Last web-browser initiated configuration change since sysUpTime." ::= { rcWeb 8 } rcWebNumHits OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of hits to the web-server" ::= { rcWeb 9 } rcWebNumAccessChecks OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of access checks performed by the web-server" ::= { rcWeb 10 } rcWebNumAccessBlocks OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of accesses blocked by the web-server" ::= { rcWeb 11 } rcWebNumRxErrors OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of receive errors encountered by the web-server" ::= { rcWeb 12 } rcWebNumTxErrors OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of transmit errors encountered by the web-server" ::= { rcWeb 13 } rcWebNumSetRequest OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of set-request to the web-server" ::= { rcWeb 14 } rcWebPrimaryHtmlSourceDir OBJECT-TYPE SYNTAX DisplayString (SIZE(0..64)) MAX-ACCESS read-write STATUS current DESCRIPTION "primary html source directory" DEFVAL { "local" } ::= { rcWeb 15 } rcWebSecondaryHtmlSourceDir OBJECT-TYPE SYNTAX DisplayString (SIZE(0..64)) MAX-ACCESS read-write STATUS current DESCRIPTION "secondary html source directory" DEFVAL { "pcmcia" } ::= { rcWeb 16 } rcWebTertiaryHtmlSourceDir OBJECT-TYPE SYNTAX DisplayString (SIZE(0..64)) MAX-ACCESS read-write STATUS current DESCRIPTION "tertiary html source directory" ::= { rcWeb 17 } rcWebRWL3UserName OBJECT-TYPE SYNTAX DisplayString (SIZE (1..20)) MAX-ACCESS read-write STATUS current DESCRIPTION "user name for the L3 web server account" ::= { rcWeb 18 } rcWebRWL3Password OBJECT-TYPE SYNTAX DisplayString (SIZE (1..20)) MAX-ACCESS read-write STATUS current DESCRIPTION "password for the L3 web server account" ::= { rcWeb 19 } rcWebRWL2UserName OBJECT-TYPE SYNTAX DisplayString (SIZE (1..20)) MAX-ACCESS read-write STATUS current DESCRIPTION "user name for the L2 web server account" ::= { rcWeb 20 } rcWebRWL2Password OBJECT-TYPE SYNTAX DisplayString (SIZE (1..20)) MAX-ACCESS read-write STATUS current DESCRIPTION "password for the L2 web server account" ::= { rcWeb 21 } rcWebDefaultDisplayRows OBJECT-TYPE SYNTAX INTEGER (10..100) MAX-ACCESS read-write STATUS current DESCRIPTION "default display rows in html page." DEFVAL { 48 } ::= { rcWeb 22 } rcWebLastHostAccessBlocked OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-only STATUS current DESCRIPTION "last host access blocked" ::= { rcWeb 23 } rcWebHelpTftpSourceDir OBJECT-TYPE SYNTAX OCTET STRING (SIZE (0..256)) MAX-ACCESS read-write STATUS current DESCRIPTION "tftp source directory for help files" ::= { rcWeb 24 } rcWebHttpPort OBJECT-TYPE SYNTAX INTEGER (1..49151) MAX-ACCESS read-write STATUS current DESCRIPTION "the HTTP port for web access" DEFVAL { 80 } ::= { rcWeb 25 } -- rcCli related information rcCliRWAUserName OBJECT-TYPE SYNTAX DisplayString (SIZE (1..20)) MAX-ACCESS read-write STATUS current DESCRIPTION "User name for the read-write-all CLI account." ::= { rcCli 1 } rcCliRWAPassword OBJECT-TYPE SYNTAX DisplayString (SIZE (0..20)) MAX-ACCESS read-write STATUS current DESCRIPTION "Password for the read-write-all CLI account." ::= { rcCli 2 } rcCliRWUserName OBJECT-TYPE SYNTAX DisplayString (SIZE (1..20)) MAX-ACCESS read-write STATUS current DESCRIPTION "User name for the read-write CLI account." ::= { rcCli 3 } rcCliRWPassword OBJECT-TYPE SYNTAX DisplayString (SIZE (0..20)) MAX-ACCESS read-write STATUS current DESCRIPTION "Password for the read-write CLI account." ::= { rcCli 4 } rcCliRWL3UserName OBJECT-TYPE SYNTAX DisplayString (SIZE (1..20)) MAX-ACCESS read-write STATUS current DESCRIPTION "User name for the read-write layer-3 CLI account." ::= { rcCli 5 } rcCliRWL3Password OBJECT-TYPE SYNTAX DisplayString (SIZE (0..20)) MAX-ACCESS read-write STATUS current DESCRIPTION "Password for the read-write layer-3 CLI account." ::= { rcCli 6 } rcCliRWL2UserName OBJECT-TYPE SYNTAX DisplayString (SIZE (1..20)) MAX-ACCESS read-write STATUS current DESCRIPTION "User name for the read-write layer-2 CLI account." ::= { rcCli 7 } rcCliRWL2Password OBJECT-TYPE SYNTAX DisplayString (SIZE (0..20)) MAX-ACCESS read-write STATUS current DESCRIPTION "Password for the read-write layer-2 CLI account." ::= { rcCli 8 } rcCliROUserName OBJECT-TYPE SYNTAX DisplayString (SIZE (1..20)) MAX-ACCESS read-write STATUS current DESCRIPTION "User name for the read-only CLI account." ::= { rcCli 9 } rcCliROPassword OBJECT-TYPE SYNTAX DisplayString (SIZE (0..20)) MAX-ACCESS read-write STATUS current DESCRIPTION "Password for the read-only CLI account." ::= { rcCli 10 } rcCliMaxTelnetSessions OBJECT-TYPE SYNTAX INTEGER (0..8) MAX-ACCESS read-write STATUS current DESCRIPTION "Used to indicate the maximum number of telnet sessions the system will support." DEFVAL { 8 } ::= { rcCli 11 } rcCliMaxRloginSessions OBJECT-TYPE SYNTAX INTEGER (0..8) MAX-ACCESS read-write STATUS current DESCRIPTION "Used to indicate the maximum number of rlogin sessions the system will support." DEFVAL { 8 } ::= { rcCli 12 } rcCliTimeout OBJECT-TYPE SYNTAX INTEGER (30..65535) MAX-ACCESS read-write STATUS current DESCRIPTION "Used to indicate the amount of idle time, in seconds to wait before timing out telnet and rlogin sessions." DEFVAL { 900 } ::= { rcCli 13 } rcCliNumAccessViolations OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Used to indicate the number of CLI access violations detected by the system." ::= { rcCli 14 } rcCliRWL1UserName OBJECT-TYPE SYNTAX DisplayString (SIZE (1..20)) MAX-ACCESS read-write STATUS current DESCRIPTION "User name for the read-write layer-1 CLI account." ::= { rcCli 15 } rcCliRWL1Password OBJECT-TYPE SYNTAX DisplayString (SIZE (0..20)) MAX-ACCESS read-write STATUS current DESCRIPTION "Password for the read-write layer-1 CLI account." ::= { rcCli 16 } rcCliPasswordChange OBJECT-TYPE SYNTAX INTEGER { ro(1), l1(2), l2(3), l3(4), rw(5), rwa(6), slboper(7), l4oper(8), oper(9), slbadmin(10), l4admin(11), ssladmin(12), commStrRo(13), commStrRw(14), commStrl3(15), commStrl2(16), commStrl1(17), webPassWdRo(18) } MAX-ACCESS read-only STATUS current DESCRIPTION "Used to indication which password is changed when sending a rcCliPasswordChange trap." ::= { rcCli 17 } rcCliPassChangeResult OBJECT-TYPE SYNTAX INTEGER { success(1), fail(2) } MAX-ACCESS read-only STATUS current DESCRIPTION "Used to indication the result of changing password when sending a rcPasswordChange trap." ::= { rcCli 18 } rcCliRWEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Enable/Disable for the read-write CLI account." DEFVAL { true } ::= { rcCli 19 } rcCliRWL1Enable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Enable/Disable for the read-write-layer1 CLI account." DEFVAL { true } ::= { rcCli 20 } rcCliRWL2Enable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Enable/Disable for the read-write-layer2 CLI account." DEFVAL { true } ::= { rcCli 21 } rcCliRWL3Enable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Enable/Disable for the read-write-layer3 CLI account." DEFVAL { true } ::= { rcCli 22 } rcCliROEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Enable/Disable for the read-only CLI account." DEFVAL { true } ::= { rcCli 23 } -- Syslog Group rcSyslogGlobal OBJECT IDENTIFIER ::= { rcSyslog 1 } rcSyslogGlobalEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Used to enable/disable the SysLog feature. When enabled this feature will send a message to a server on a network that this configured to receive and store diagnostic messages from this device. The type of messages sent is user configurable." DEFVAL { true } ::= { rcSyslogGlobal 1 } rcSyslogGlobalMaxHosts OBJECT-TYPE SYNTAX INTEGER (0..10) MAX-ACCESS read-write STATUS current DESCRIPTION "Maximun number of remote hosts considered 'active' and able to receive messages from the Syslog service on the router." DEFVAL { 5 } ::= { rcSyslogGlobal 2 } rcSyslogGlobalOperState OBJECT-TYPE SYNTAX INTEGER { active(1), inactive(2), emptyHostTbl(3), allHostDisabled(4) } MAX-ACCESS read-only STATUS current DESCRIPTION "The operational state of the syslog service on the router." DEFVAL { active } ::= { rcSyslogGlobal 3 } rcSyslogHostTbl OBJECT-TYPE SYNTAX SEQUENCE OF RcSyslogHostEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Table of remote host destinations for syslog." ::= { rcSyslog 2 } rcSyslogHostEntry OBJECT-TYPE SYNTAX RcSyslogHostEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry containing information for a particular entry in rcSyslogHostTable." INDEX { rcSyslogHostId } ::= { rcSyslogHostTbl 1 } RcSyslogHostEntry ::= SEQUENCE { rcSyslogHostId INTEGER, rcSyslogHostIpAddr IpAddress, rcSyslogHostUdpPort INTEGER, rcSyslogHostFacility INTEGER, rcSyslogHostModuleId INTEGER, rcSyslogHostModuleId2 Integer32, rcSyslogHostSeverity INTEGER, rcSyslogHostMapInfoSeverity INTEGER, rcSyslogHostMapWarningSeverity INTEGER, rcSyslogHostMapErrorSeverity INTEGER, rcSyslogHostMapMfgSeverity INTEGER, rcSyslogHostMapFatalSeverity INTEGER, rcSyslogHostMapTraceMsg INTEGER, rcSyslogHostMapTrapMsg INTEGER, rcSyslogHostLogTraceMsgs TruthValue, rcSyslogHostLogTrapMsgs TruthValue, rcSyslogHostEnable TruthValue, rcSyslogHostRowStatus RowStatus } rcSyslogHostId OBJECT-TYPE SYNTAX INTEGER (1..10) MAX-ACCESS read-only STATUS current DESCRIPTION "Host Id." ::= { rcSyslogHostEntry 1 } rcSyslogHostIpAddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Host Ip Address" ::= { rcSyslogHostEntry 2 } rcSyslogHostUdpPort OBJECT-TYPE SYNTAX INTEGER (514..530) MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the UDP port to use to send syslog messages to the host." DEFVAL { 514 } ::= { rcSyslogHostEntry 3 } rcSyslogHostFacility OBJECT-TYPE SYNTAX INTEGER { local0(128), local1(136), local2(144), local3(152), local4(160), local5(168), local6(176), local7(184) } MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the UNIX facility used in messages to the syslog host. Default is LOCAL7." DEFVAL { local7 } ::= { rcSyslogHostEntry 4 } rcSyslogHostModuleId OBJECT-TYPE SYNTAX INTEGER { common (1), -- '00000001'H snmp (2), -- '00000002'H rmon (4), -- '00000004'H portmgr (8), -- '00000008'H chasmgr (16), -- '00000010'H bridge (32), -- '00000020'H ospf (64), -- '00000040'H hwif (128), -- '00000080'H sim (256), -- '00000100'H cpp (512), -- '00000200'H netdrv (1024), -- '00000400'H vlanmgr (2048), -- '00000800'H cli (4096), -- '00001000'H main (8192), -- '00002000'H p2ip (16384), -- '00004000'H rcip (32768), -- '00008000'H rompager (65536), -- '00010000'H acif (131072), -- '00020000'H gbip (262144), -- '00040000'H wdt (524288), -- '00080000'H tdp (1048576), -- '00100000'H mandiag (2097152), -- '00200000'H mantest (4194304), -- '00400000'H igmp (8388608), -- '00800000'H ipfil (16777216), -- '01000000'H mlt (33554432), -- '02000000'H ippolicy(67108864), -- '04000000'H ipmc (134217728), -- '08000000'H syslog (268435456) -- '10000000'H } MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies for which modules/tasks syslog messages should be sent. Default is all modules/tasks." ::= { rcSyslogHostEntry 5 } rcSyslogHostModuleId2 OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies for which modules/tasks syslog messages should be sent. Default is all modules/tasks." ::= { rcSyslogHostEntry 6 } rcSyslogHostSeverity OBJECT-TYPE SYNTAX INTEGER (1..31) MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the severity level for which syslog messages should be sent for the modules specifies in 'SyslogHostModule'. Value is one of multiple (logical 'OR') of the following: info(1), warning(2), error(4), mfg(8), fatal(16)." DEFVAL { 1 } ::= { rcSyslogHostEntry 7 } rcSyslogHostMapInfoSeverity OBJECT-TYPE SYNTAX INTEGER { emergency(1), alert(2), critical(3), error(4), warning(5), notice(6), info(7), debug(8) } MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the syslog severity to use for Accelar INFO messages. Default is INFO." DEFVAL { info } ::= { rcSyslogHostEntry 8 } rcSyslogHostMapWarningSeverity OBJECT-TYPE SYNTAX INTEGER { emergency(1), alert(2), critical(3), error(4), warning(5), notice(6), info(7), debug(8) } MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the syslog severity to use for Accelar WARNING messages. Default is WARNING. Should be less than or equal to INFO." DEFVAL { warning } ::= { rcSyslogHostEntry 9 } rcSyslogHostMapErrorSeverity OBJECT-TYPE SYNTAX INTEGER { emergency(1), alert(2), critical(3), error(4), warning(5), notice(6), info(7), debug(8) } MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the syslog severity to use for Accelar ERROR messages. Default is ERROR. Should be less than or equal to WARNING." DEFVAL { error } ::= { rcSyslogHostEntry 10 } rcSyslogHostMapMfgSeverity OBJECT-TYPE SYNTAX INTEGER { emergency(1), alert(2), critical(3), error(4), warning(5), notice(6), info(7), debug(8) } MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the syslog severity to use for Accelar Manufactoring messages. Dafault is ERROR." DEFVAL { error } ::= { rcSyslogHostEntry 11 } rcSyslogHostMapFatalSeverity OBJECT-TYPE SYNTAX INTEGER { emergency(1), alert(2), critical(3), error(4), warning(5), notice(6), info(7), debug(8) } MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the syslog severity to use for Accelar FATAL messages. Default is EMERGENCY. Should be less than or equal to ERROR." DEFVAL { emergency } ::= { rcSyslogHostEntry 12 } rcSyslogHostMapTraceMsg OBJECT-TYPE SYNTAX INTEGER { emergency(1), alert(2), critical(3), error(4), warning(5), notice(6), info(7), debug(8) } MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the syslog severity to use for syslog trace messages. Default is DEBUG." ::= { rcSyslogHostEntry 13 } rcSyslogHostMapTrapMsg OBJECT-TYPE SYNTAX INTEGER { emergency(1), alert(2), critical(3), error(4), warning(5), notice(6), info(7), debug(8) } MAX-ACCESS read-write STATUS current DESCRIPTION "Specifies the UNIX severity code to use for syslog messages for SNMP traps sent to the syslog host. Default is INFO." ::= { rcSyslogHostEntry 14 } rcSyslogHostLogTraceMsgs OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Indicate whether to activate the host to log the syslog trace messages." ::= { rcSyslogHostEntry 15 } rcSyslogHostLogTrapMsgs OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Indicate whether to activate the host to log the syslog messages for SNMP traps." ::= { rcSyslogHostEntry 16 } rcSyslogHostEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Enable/Disable messages to be sent to syslog host." DEFVAL { false } ::= { rcSyslogHostEntry 17 } rcSyslogHostRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-write STATUS current DESCRIPTION "Used to create/delete entries in the rcSyslogTable." ::= { rcSyslogHostEntry 18 } -- System Time Grp rcUserSetTimeYear OBJECT-TYPE SYNTAX INTEGER (1998..2097) MAX-ACCESS read-write STATUS current DESCRIPTION "Year of the time." DEFVAL {1998} ::= { rcUserSetTime 1 } rcUserSetTimeMonth OBJECT-TYPE SYNTAX INTEGER (1..12) MAX-ACCESS read-write STATUS current DESCRIPTION "Month of the time." DEFVAL {1} ::= { rcUserSetTime 2 } rcUserSetTimeDate OBJECT-TYPE SYNTAX INTEGER (1..31) MAX-ACCESS read-write STATUS current DESCRIPTION "Date of the time." DEFVAL {1} ::= { rcUserSetTime 3 } rcUserSetTimeHour OBJECT-TYPE SYNTAX INTEGER (0..23) MAX-ACCESS read-write STATUS current DESCRIPTION "Hour of the time." DEFVAL {0} ::= { rcUserSetTime 4 } rcUserSetTimeMinute OBJECT-TYPE SYNTAX INTEGER (0..59) MAX-ACCESS read-write STATUS current DESCRIPTION "Minute of the time." DEFVAL {0} ::= { rcUserSetTime 5 } rcUserSetTimeSecond OBJECT-TYPE SYNTAX INTEGER (0..59) MAX-ACCESS read-write STATUS current DESCRIPTION "Second of the time." DEFVAL {0} ::= { rcUserSetTime 6 } -- RecRecord rcRecReservTable OBJECT-TYPE SYNTAX SEQUENCE OF RcRecReservEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table would display the statistics of several HW record type used. This will also let the user reserve certain number of records for each type." ::= { rcRec 1 } rcRecReservTablEntry OBJECT-TYPE SYNTAX RcRecReservEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "" INDEX { rcRecReservRecordType } ::= { rcRecReservTable 1 } RcRecReservEntry ::= SEQUENCE { rcRecReservRecordType INTEGER, rcRecReservUsed Integer32, rcRecReservReserved Integer32, rcRecReservNewReserved Integer32, rcRecReservDefReserved Integer32 } rcRecReservRecordType OBJECT-TYPE SYNTAX INTEGER { filter(1), ipmc(2), local(3), mac(4), static(5), vrrp(6) } MAX-ACCESS read-only STATUS current DESCRIPTION "." ::= { rcRecReservTablEntry 1 } rcRecReservUsed OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Displayes the number of HW records actually usee by the recordType." ::= { rcRecReservTablEntry 2 } rcRecReservReserved OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Displayes the number of HW records reserved for the recordType." ::= { rcRecReservTablEntry 3 } rcRecReservNewReserved OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Displayes the number of HW records that w ill be reserved for this recordType after reset if the configuration is saved." ::= { rcRecReservTablEntry 4 } rcRecReservDefReserved OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Number of records reserved for this recordType if loaded with factory default." ::= { rcRecReservTablEntry 5 } -- SSH Group -- SSH Global Information. All requires RWA access. rcSshGlobal OBJECT IDENTIFIER ::= { rcSsh 1 } rcSshGlobalVersion OBJECT-TYPE SYNTAX INTEGER { v2only(1), both(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "SSH version" DEFVAL { v2only } ::= { rcSshGlobal 1 } rcSshGlobalPort OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "SSH connection port." DEFVAL { 22 } ::= { rcSshGlobal 2 } rcSshGlobalMaxSession OBJECT-TYPE SYNTAX INTEGER (0..8) MAX-ACCESS read-write STATUS current DESCRIPTION "Number of session allowed." DEFVAL { 4 } ::= { rcSshGlobal 3 } rcSshGlobalTimeout OBJECT-TYPE SYNTAX INTEGER (1..120) MAX-ACCESS read-write STATUS current DESCRIPTION "SSH connection timeout in seconds." DEFVAL { 60 } ::= { rcSshGlobal 4 } rcSshGlobalRsaKeySize OBJECT-TYPE SYNTAX INTEGER (0|512..1024) MAX-ACCESS read-write STATUS current DESCRIPTION "SSH Rsa key size." DEFVAL { 1024 } ::= { rcSshGlobal 5 } rcSshGlobalDsaKeySize OBJECT-TYPE SYNTAX INTEGER (0|512..1024) MAX-ACCESS read-write STATUS current DESCRIPTION "SSH Dsa key size." DEFVAL { 1024 } ::= { rcSshGlobal 6 } rcSshGlobalRsaAuth OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Enable/disable SSH RSA authentication" DEFVAL { true } ::= { rcSshGlobal 7 } rcSshGlobalDsaAuth OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Enable/disable SSH DSA authentication" DEFVAL { true } ::= { rcSshGlobal 8 } rcSshGlobalPassAuth OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "Enable/disable SSH RSA authentication" DEFVAL { true } ::= { rcSshGlobal 9 } rcSshGlobalKeyAction OBJECT-TYPE SYNTAX INTEGER { none(0), generateDsa(1), generateRsa(2), deleteDsa(3), deleteRsa(4) } MAX-ACCESS read-write STATUS current DESCRIPTION "SSH key action." ::= { rcSshGlobal 10 } rcSshGlobalEnable OBJECT-TYPE SYNTAX INTEGER { false(0), true(1), secure(2) } MAX-ACCESS read-write STATUS current DESCRIPTION "Enable/disable, or securely enable SSH. Securely enable turns off other daemon flag, and it takes ffect afte reboot" DEFVAL { false } ::= { rcSshGlobal 11 } rcSshGlobalHostIpAddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-write STATUS current DESCRIPTION "current remote ip addr" ::= { rcSshGlobal 12 } rcSslMipTable OBJECT-TYPE SYNTAX SEQUENCE OF RcSslMipEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table would display the MIP of the SSL blade according to the slot number." ::= { rcSsh 2 } rcSslMipTableEntry OBJECT-TYPE SYNTAX RcSslMipEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "This table get the MIP of the SSL blade on which the blade is in different cluster." INDEX { rcSslMipSlot } ::= { rcSslMipTable 1 } RcSslMipEntry ::= SEQUENCE { rcSslMipSlot Integer32, rcSslMipMip DisplayString } rcSslMipSlot OBJECT-TYPE SYNTAX Integer32 (0..2147483647) MAX-ACCESS read-only STATUS current DESCRIPTION "Used as an index to find out the MIP of SSL blade." ::= { rcSslMipTableEntry 1 } rcSslMipMip OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Master IP of the SSL blade." ::= { rcSslMipTableEntry 2 } -- LACP Group -- LACP Global Information. rcLacpGlobal OBJECT IDENTIFIER ::= { rcLacp 1 } rcLacpGlobalEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "globally enable/disable LACP" DEFVAL { false } ::= { rcLacpGlobal 1 } rcLacpGlobalSystemPriority OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "set system priority to all the LACP enabled aggregators and prots" DEFVAL { 32768 } ::= { rcLacpGlobal 2 } rcLacpGlobalFastPeriodicTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The number of miliseconds between periodic transmissions using Short Timeouts. Set this value to all LACP enabled ports." DEFVAL { 1000 } ::= { rcLacpGlobal 3 } rcLacpGlobalSlowPeriodicTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The number of miliseconds between periodic transmissions using LONG Timeouts. Set this value to all LACP enabled ports." DEFVAL { 30000 } ::= { rcLacpGlobal 4 } rcLacpGlobalTimeoutScale OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Scalar value used to calculate timeout time from periodic time. Set this value to all LACP enabled ports." DEFVAL { 3 } ::= { rcLacpGlobal 5 } rcLacpGlobalAggrWaitTime OBJECT-TYPE SYNTAX INTEGER (200..2000) MAX-ACCESS read-write STATUS current DESCRIPTION "The number of mili seconds to delay aggregation to allow multiple links to aggregate simultaneously." DEFVAL { 2000 } ::= { rcLacpGlobal 6 } rcLacpGlobalVlacpEnable OBJECT-TYPE SYNTAX TruthValue MAX-ACCESS read-write STATUS current DESCRIPTION "globally enable/disable Virtual LACP" DEFVAL { false } ::= { rcLacpGlobal 7 } rcLacpGlobalVlacpMulticastMACAddress OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS read-write STATUS current DESCRIPTION "Virtual LACP multicast MAC address" ::= { rcLacpGlobal 8 } -- rcVlacpPeerMacAddressTable rcVlacpPeerMacAddressTable OBJECT-TYPE SYNTAX SEQUENCE OF RcVlacpPeerMacAddressEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " Virtual LACP Peer Mac Address table" ::= { rcLacp 2 } rcVlacpPeerMacAddressEntry OBJECT-TYPE SYNTAX RcVlacpPeerMacAddressEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Entry containing info. for a particular peer" INDEX { rcVlacpPeerMacAddressMAC } ::= { rcVlacpPeerMacAddressTable 1 } RcVlacpPeerMacAddressEntry ::= SEQUENCE { rcVlacpPeerMacAddressMAC MacAddress, rcVlacpPeerMacAddressMltId INTEGER, rcVlacpPeerMacAddressPort InterfaceIndex, rcVlacpPeerMacAddressIpAddr IpAddress, rcVlacpPeerMacAddressRowStatus RowStatus } rcVlacpPeerMacAddressMAC OBJECT-TYPE SYNTAX MacAddress MAX-ACCESS not-accessible STATUS current DESCRIPTION "Virtual LACP peer mac address on a port/MLT" ::= { rcVlacpPeerMacAddressEntry 1 } rcVlacpPeerMacAddressMltId OBJECT-TYPE SYNTAX INTEGER(1..32) MAX-ACCESS read-create STATUS current DESCRIPTION "MLT Id on which Virtual LACP peer mac address is directly or indirectly connected" ::= { rcVlacpPeerMacAddressEntry 2 } rcVlacpPeerMacAddressPort OBJECT-TYPE SYNTAX InterfaceIndex MAX-ACCESS read-create STATUS current DESCRIPTION "Ports on which Virtual LACP peer mac address is directly or indirectly connected" ::= { rcVlacpPeerMacAddressEntry 3 } rcVlacpPeerMacAddressIpAddr OBJECT-TYPE SYNTAX IpAddress MAX-ACCESS read-create STATUS current DESCRIPTION "Virtual LACP peer Ip Address on port/MLT" ::= { rcVlacpPeerMacAddressEntry 4 } rcVlacpPeerMacAddressRowStatus OBJECT-TYPE SYNTAX RowStatus MAX-ACCESS read-create STATUS current DESCRIPTION "Used to create/delete entries in the peer address table" ::= { rcVlacpPeerMacAddressEntry 5 } END