-- IF-MIB.my: Interfaces MIB
--
-- May 1994, Jeffrey T. Johnson
--
-- Copyright (c) 1994 - 1996 by cisco Systems, Inc.
-- All rights reserved.
--
-- *****************************************************************
--
-- extracted from draft-ietf-ifmib-mib-03.txt
-- major differences with RFC1573 -
-- Added InterfaceIndexOrZero textual convention.
-- Added notPresent state for ifOperStatus.
-- Added the ifAlias, ifStackLastChange and ifTableLastChange objects.
-- Corrected the MAX-ACCESS clause values for
-- ifRcvAddressAddress, ifRcvAddressStatus and ifStackStatus.
--
-- the following modifications have been applied:
-- changed "RFC-1213" to "RFC1213-MIB"
-- added import of snmpTraps
IF-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, Counter32, Gauge32,
Integer32, TimeTicks, Counter64,
NOTIFICATION-TYPE FROM SNMPv2-SMI
TEXTUAL-CONVENTION, DisplayString,
PhysAddress, TruthValue, RowStatus,
AutonomousType, TestAndIncr FROM SNMPv2-TC
MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF
snmpTraps FROM SNMPv2-MIB
IANAifType FROM IANAifType-MIB
mib-2,interfaces FROM RFC1213-MIB;
ifMIB MODULE-IDENTITY
LAST-UPDATED "9602221355Z"
ORGANIZATION "IETF Interfaces MIB Working Group"
CONTACT-INFO
" Keith McCloghrie
Cisco Systems, Inc.
170 West Tasman Drive
San Jose, CA 95134-1706
US
408-526-5260
kzm@cisco.com"
DESCRIPTION
"The MIB module to describe generic objects for
network interface sub-layers. This MIB is an updated
version of MIB-II's ifTable, and incorporates the
extensions defined in RFC 1229."
REVISION "9602282155Z"
DESCRIPTION
"Revisions made by the Interfaces MIB WG."
REVISION "9311082155Z"
DESCRIPTION
"Initial revision, published as part of RFC 1573."
::= { mib-2 31 }
ifMIBObjects OBJECT IDENTIFIER ::= { ifMIB 1 }
-- OwnerString has the same semantics as used in RFC 1271
OwnerString ::= TEXTUAL-CONVENTION
DISPLAY-HINT "255a"
STATUS current
DESCRIPTION
"This data type is used to model an administratively
assigned name of the owner of a resource. This
information is taken from the NVT ASCII character set.
It is suggested that this name contain one or more of
the following: ASCII form of the manager station's
transport address, management station name (e.g.,
domain name), network management personnel's name,
location, or phone number. In some cases the agent
itself will be the owner of an entry. In these cases,
this string shall be set to a string starting with
'agent'."
SYNTAX OCTET STRING (SIZE(0..255))
-- InterfaceIndex contains the semantics of ifIndex and
-- should be used for any objects defined on other mib
-- modules that need these semantics.
InterfaceIndex ::= TEXTUAL-CONVENTION
DISPLAY-HINT "d"
STATUS current
DESCRIPTION
"A unique value, greater than zero, for each interface
or interface sub-layer in the managed system. It is
recommended that values are assigned contiguously
starting from 1. The value for each interface sub-
layer must remain constant at least from one re-
initialization of the entity's network management
system to the next re-initialization."
SYNTAX Integer32
InterfaceIndexOrZero ::= TEXTUAL-CONVENTION
DISPLAY-HINT "d"
STATUS current
DESCRIPTION
"This textual convention is an extension of the
InterfaceIndex convention. The latter defines a
greater than zero to identify an interface or
interface sub-layer in the managed system. This
extension permits the additional value of zero. the
value zero is object-specific and must therefore be
defined as part of the description of any object which
uses this syntax. Examples of the usage of zero might
include situations where interface was unknown, or
when none or all interfaces need to be referenced."
SYNTAX Integer32 (0..2147483647)
ifNumber OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of network interfaces (regardless of their
current state) present on this system."
::= { interfaces 1 }
ifTableLastChange OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime at the time of the last
creation or deletion of an entry in the ifTable. If
the number of entries has been unchanged since the
last re-initialization of the local network management
subsystem, then this object contains a zero value."
::= { ifMIBObjects 5 }
-- the Interfaces table
-- The Interfaces table contains information on the entity's
-- interfaces. Each sub-layer below the internetwork-layer
-- of a network interface is considered to be an interface.
ifTable OBJECT-TYPE
SYNTAX SEQUENCE OF IfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of interface entries. The number of entries
is given by the value of ifNumber."
::= { interfaces 2 }
ifEntry OBJECT-TYPE
SYNTAX IfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing management information applicable
to a particular interface."
INDEX { ifIndex }
::= { ifTable 1 }
IfEntry ::=
SEQUENCE {
ifIndex InterfaceIndex,
ifDescr DisplayString,
ifType IANAifType,
ifMtu Integer32,
ifSpeed Gauge32,
ifPhysAddress PhysAddress,
ifAdminStatus INTEGER,
ifOperStatus INTEGER,
ifLastChange TimeTicks,
ifInOctets Counter32,
ifInUcastPkts Counter32,
ifInNUcastPkts Counter32, -- deprecated
ifInDiscards Counter32,
ifInErrors Counter32,
ifInUnknownProtos Counter32,
ifOutOctets Counter32,
ifOutUcastPkts Counter32,
ifOutNUcastPkts Counter32, -- deprecated
ifOutDiscards Counter32,
ifOutErrors Counter32,
ifOutQLen Gauge32, -- deprecated
ifSpecific OBJECT IDENTIFIER -- deprecated
}
ifIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique value, greater than zero, for each
interface. It is recommended that values are assigned
contiguously starting from 1. The value for each
interface sub-layer must remain constant at least from
one re-initialization of the entity's network
management system to the next re-initialization."
::= { ifEntry 1 }
ifDescr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A textual string containing information about the
interface. This string should include the name of the
manufacturer, the product name and the version of the
interface hardware/software."
::= { ifEntry 2 }
ifType OBJECT-TYPE
SYNTAX IANAifType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of interface. Additional values for ifType
are assigned by the Internet Assigned Numbers
Authority (IANA), through updating the syntax of the
IANAifType textual convention."
::= { ifEntry 3 }
ifMtu OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The size of the largest packet which can be
sent/received on the interface, specified in octets.
For interfaces that are used for transmitting network
datagrams, this is the size of the largest network
datagram that can be sent on the interface."
::= { ifEntry 4 }
ifSpeed OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An estimate of the interface's current bandwidth in
bits per second. For interfaces which do not vary in
bandwidth or for those where no accurate estimation
can be made, this object should contain the nominal
bandwidth. If the bandwidth of the interface is
greater than the maximum value reportable by this
object then this object should report its maximum
value (4,294,967,295) and ifHighSpeed must be used to
report the interace's speed. For a sub-layer which
has no concept of bandwidth, this object should be
zero."
::= { ifEntry 5 }
ifPhysAddress OBJECT-TYPE
SYNTAX PhysAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The interface's address at its protocol sub-layer.
The interface's media-specific MIB must define the bit
and byte ordering and format of the value contained by
this object. For interfaces which do not have such an
address (e.g., a serial line), this object should
contain an octet string of zero length."
::= { ifEntry 6 }
ifAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
up(1), -- ready to pass packets
down(2),
testing(3) -- in some test mode
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The desired state of the interface. The testing(3)
state indicates that no operational packets can be
passed. When a managed system initializes, all
interfaces start with ifAdminStatus in the down(2)
state. As a result of either explicit management
action or per configuration information retained by
the managed system, ifAdminStatus is then changed to
either the up(1) or testing(3) states (or remains in
the down(2) state)."
::= { ifEntry 7 }
ifOperStatus OBJECT-TYPE
SYNTAX INTEGER {
up(1), -- ready to pass packets
down(2),
testing(3), -- in some test mode
unknown(4), -- status can not be determined
-- for some reason.
dormant(5),
notPresent(6) -- some component is missing
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current operational state of the interface. The
testing(3) state indicates that no operational packets
can be passed. If ifAdminStatus is down(2) then
ifOperStatus should be down(2). If ifAdminStatus is
changed to up(1) then ifOperStatus should change to
up(1) if the interface is ready to transmit and
receive network traffic; it should change to
dormant(5) if the interface is waiting for external
actions (such as a serial line waiting for an
incoming connection); it should remain in the down(2)
state if and only if there is a fault that prevents if
from going to the up(1) state; it should remain in the
notPresent(6) state if the interface has missing
(typically, hardware) components."
::= { ifEntry 8 }
ifLastChange OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime at the time the interface
entered its current operational state. If the current
state was entered prior to the last re-initialization
of the local network management subsystem, then this
object contains a zero value."
::= { ifEntry 9 }
ifInOctets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of octets received on the interface,
including framing characters."
::= { ifEntry 10 }
ifInUcastPkts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets, delivered by this sub-layer to
a higher (sub-)layer, which were not addressed to a
multicast or broadcast address at this sub-layer."
::= { ifEntry 11 }
ifInNUcastPkts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"The number of packets, delivered by this sub-layer to
a higher (sub-)layer, which were addressed to a
multicast or broadcast address at this sub-layer.
This object is deprecated in favor of
ifInMulticastPkts and ifInBroadcastPkts."
::= { ifEntry 12 }
ifInDiscards OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of inbound packets which were chosen to be
discarded even though no errors had been detected to
prevent their being deliverable to a higher-layer
protocol. One possible reason for discarding such a
packet could be to free up buffer space."
::= { ifEntry 13 }
ifInErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"For packet-oriented interfaces, the number of inbound
packets that contained errors preventing them from
being deliverable to a higher-layer protocol. For
character-oriented or fixed-length interfaces, the
number of inbound transmission units that contained
errors preventing them from being deliverable to a
higher-layer protocol."
::= { ifEntry 14 }
ifInUnknownProtos OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"For packet-oriented interfaces, the number of packets
received via the interface which were discarded
because of an unknown or unsupported protocol. For
character-oriented or fixed-length interfaces which
support protocol multiplexing the number of
transmission units received via the interface which
were discarded because of an unknown or unsupported
protocol. For any interface which does not support
protocol multiplexing, this counter will always be 0."
::= { ifEntry 15 }
ifOutOctets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of octets transmitted out of the
interface, including framing characters."
::= { ifEntry 16 }
ifOutUcastPkts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets that higher-level
protocols requested be transmitted, and which were not
addressed to a multicast or broadcast address at this
sub-layer, including those that were discarded or not
sent."
::= { ifEntry 17 }
ifOutNUcastPkts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"The total number of packets that higher-level
protocols requested be transmitted, and which were
addressed to a multicast or broadcast address at this
sub-layer, including those that were discarded or not
sent.
This object is deprecated in favour of
ifOutMulticastPkts and ifOutBroadcastPkts."
::= { ifEntry 18 }
ifOutDiscards OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of outbound packets which were chosen to
be discarded even though no errors had been detected
to prevent their being transmitted. One possible
reason for discarding such a packet could be to free
up buffer space."
::= { ifEntry 19 }
ifOutErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"For packet-oriented interfaces, the number of
outbound packets that could not be transmitted because
of errors. For character-oriented or fixed-length
interfaces, the number of outbound transmission units
that could not be transmitted because of errors."
::= { ifEntry 20 }
ifOutQLen OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"The length of the output packet queue (in packets)."
::= { ifEntry 21 }
ifSpecific OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"A reference to MIB definitions specific to the
particular media being used to realize the interface.
It is recommended that this value point to an instance
of a MIB object in the media-specific MIB, i.e., that
this object have the semantics associated with the
InstancePointer textual convention defined in RFC
1443. In fact, it is recommended that the media-
specific MIB specify what value ifSpecific should/can
take for values of ifType. If no MIB definitions
specific to the particular media are available, the
value should be set to the OBJECT IDENTIFIER { 0 0 }."
::= { ifEntry 22 }
--
-- Extension to the interface table
--
-- This table replaces the ifExtnsTable table.
--
ifXTable OBJECT-TYPE
SYNTAX SEQUENCE OF IfXEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of interface entries. The number of entries
is given by the value of ifNumber. This table
contains additional objects for the interface table."
::= { ifMIBObjects 1 }
ifXEntry OBJECT-TYPE
SYNTAX IfXEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing additional management information
applicable to a particular interface."
AUGMENTS { ifEntry }
::= { ifXTable 1 }
IfXEntry ::=
SEQUENCE {
ifName DisplayString,
ifInMulticastPkts Counter32,
ifInBroadcastPkts Counter32,
ifOutMulticastPkts Counter32,
ifOutBroadcastPkts Counter32,
ifHCInOctets Counter64,
ifHCInUcastPkts Counter64,
ifHCInMulticastPkts Counter64,
ifHCInBroadcastPkts Counter64,
ifHCOutOctets Counter64,
ifHCOutUcastPkts Counter64,
ifHCOutMulticastPkts Counter64,
ifHCOutBroadcastPkts Counter64,
ifLinkUpDownTrapEnable INTEGER,
ifHighSpeed Gauge32,
ifPromiscuousMode TruthValue,
ifConnectorPresent TruthValue,
ifAlias DisplayString
}
ifName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The textual name of the interface. The value of this
object should be the name of the interface as assigned
by the local device and should be suitable for use in
commands entered at the device's `console'. This
might be a text name, such as `le0' or a simple port
number, such as `1', depending on the interface naming
syntax of the device. If several entries in the
ifTable together represent a single interface as named
by the device, then each will have the same value of
ifName. If there is no local name, or this object is
otherwise not applicable, then this object contains a
0-length string."
::= { ifXEntry 1 }
ifInMulticastPkts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets, delivered by this sub-layer to
a higher (sub-)layer, which were addressed to a
multicast address at this sub-layer. For a MAC layer
protocol, this includes both Group and Functional
addresses."
::= { ifXEntry 2 }
ifInBroadcastPkts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets, delivered by this sub-layer to
a higher (sub-)layer, which were addressed to a
broadcast address at this sub-layer."
::= { ifXEntry 3 }
ifOutMulticastPkts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets that higher-level
protocols requested be transmitted, and which were
addressed to a multicast address at this sub-layer,
including those that were discarded or not sent. For
a MAC layer protocol, this includes both Group and
Functional addresses."
::= { ifXEntry 4 }
ifOutBroadcastPkts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets that higher-level
protocols requested be transmitted, and which were
addressed to a broadcast address at this sub-layer,
including those that were discarded or not sent."
::= { ifXEntry 5 }
--
-- High Capacity Counter objects. These objects are all
-- 64 bit versions of the "basic" ifTable counters. These
-- objects all have the same basic semantics as their 32-bit
-- counterparts, however, their syntax has been extended
-- to 64 bits.
--
ifHCInOctets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of octets received on the interface,
including framing characters. This object is a 64-bit
version of ifInOctets."
::= { ifXEntry 6 }
ifHCInUcastPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets, delivered by this sub-layer to
a higher (sub-)layer, which were not addressed to a
multicast or broadcast address at this sub-layer.
This object is a 64-bit version of ifInUcastPkts."
::= { ifXEntry 7 }
ifHCInMulticastPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets, delivered by this sub-layer to
a higher (sub-)layer, which were addressed to a
multicast address at this sub-layer. For a MAC layer
protocol, this includes both Group and Functional
addresses. This object is a 64-bit version of
ifInMulticastPkts."
::= { ifXEntry 8 }
ifHCInBroadcastPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets, delivered by this sub-layer to
a higher (sub-)layer, which were addressed to a
broadcast address at this sub-layer. This object is a
64-bit version of ifInBroadcastPkts."
::= { ifXEntry 9 }
ifHCOutOctets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of octets transmitted out of the
interface, including framing characters. This object
is a 64-bit version of ifOutOctets."
::= { ifXEntry 10 }
ifHCOutUcastPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets that higher-level
protocols requested be transmitted, and which were not
addressed to a multicast or broadcast address at this
sub-layer, including those that were discarded or not
sent. This object is a 64-bit version of
ifOutUcastPkts."
::= { ifXEntry 11 }
ifHCOutMulticastPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets that higher-level
protocols requested be transmitted, and which were
addressed to a multicast address at this sub-layer,
including those that were discarded or not sent. For
a MAC layer protocol, this includes both Group and
Functional addresses. This object is a 64-bit version
of ifOutMulticastPkts."
::= { ifXEntry 12 }
ifHCOutBroadcastPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets that higher-level
protocols requested be transmitted, and which were
addressed to a broadcast address at this sub-layer,
including those that were discarded or not sent. This
object is a 64-bit version of ifOutBroadcastPkts."
::= { ifXEntry 13 }
ifLinkUpDownTrapEnable OBJECT-TYPE
SYNTAX INTEGER { enabled(1), disabled(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates whether linkUp/linkDown traps should be
generated for this interface.
By default, this object should have the value
enabled(1) for interfaces which do not operate on
'top' of any other interface (as defined in the
ifStackTable), and disabled(2) otherwise."
::= { ifXEntry 14 }
ifHighSpeed OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An estimate of the interface's current bandwidth in
units of 1,000,000 bits per second. If this object
reports a value of `n' then the speed of the interface
is somewhere in the range of `n-500,000' to
`n+499,999'. For interfaces which do not vary in
bandwidth or for those where no accurate estimation
can be made, this object should contain the nominal
bandwidth. For a sub-layer which has no concept of
bandwidth, this object should be zero."
::= { ifXEntry 15 }
ifPromiscuousMode OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object has a value of false(2) if this interface
only accepts packets/frames that are addressed to this
station. This object has a value of true(1) when the
station accepts all packets/frames transmitted on the
media. The value true(1) is only legal on certain
types of media. If legal, setting this object to a
value of true(1) may require the interface to be reset
before becoming effective.
The value of ifPromiscuousMode does not affect the
reception of broadcast and multicast packets/frames by
the interface."
::= { ifXEntry 16 }
ifConnectorPresent OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object has the value 'true(1)' if the interface
sublayer has a physical connector and the value
'false(2)' otherwise."
::= { ifXEntry 17 }
ifAlias OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is an 'alias' name for the interface as
specified by a network manager, and provides a non-
volatile 'handle' for the interface.
On the first instantiation of an interface, the value
of ifAlias associated with that interface is the
zero-length string. As and when a value is written
into an instance of ifAlias through a network
management set operation, then the agent must retain
the supplied value in the ifAlias instance associated
with the same interface for as long as that interface
remains instantiated, including across all re-
initializations/reboots of the network management
system, including those which result in a change of
the interface's ifIndex value.
An example of the value which a network manager might
store in this object for a WAN interface is the
(Telco's) circuit number/identifier of the interface.
Some agents may support write-access only for
interfaces having particular values of ifType. An
agent which supports write access to this object is
required to keep the value in non-volatile storage,
but it may limit the length of new values depending on
how much storage is already occupied by the current
values for other interfaces."
::= { ifXEntry 18 }
-- The Interface Stack Group
--
-- Implementation of this group is mandatory for all systems
--
ifStackTable OBJECT-TYPE
SYNTAX SEQUENCE OF IfStackEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table containing information on the relationships
between the multiple sub-layers of network interfaces.
In particular, it contains information on which sub-
layers run 'on top of' which other sub-layers. Each
sub-layer corresponds to a conceptual row in the
ifTable."
::= { ifMIBObjects 2 }
ifStackEntry OBJECT-TYPE
SYNTAX IfStackEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Information on a particular relationship between two
sub-layers, specifying that one sub-layer runs on
'top' of the other sub-layer. Each sub-layer
corresponds to a conceptual row in the ifTable."
INDEX { ifStackHigherLayer, ifStackLowerLayer }
::= { ifStackTable 1 }
IfStackEntry ::=
SEQUENCE {
ifStackHigherLayer Integer32,
ifStackLowerLayer Integer32,
ifStackStatus RowStatus
}
ifStackHigherLayer OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of ifIndex corresponding to the higher
sub-layer of the relationship, i.e., the sub-layer
which runs on 'top' of the sub-layer identified by the
corresponding instance of ifStackLowerLayer. If there
is no higher sub-layer (below the internetwork layer),
then this object has the value 0."
::= { ifStackEntry 1 }
ifStackLowerLayer OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of ifIndex corresponding to the lower sub-
layer of the relationship, i.e., the sub-layer which
runs 'below' the sub-layer identified by the
corresponding instance of ifStackHigherLayer. If
there is no lower sub-layer, then this object has the
value 0."
::= { ifStackEntry 2 }
ifStackStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The status of the relationship between two sub-
layers.
Changing the value of this object from 'active' to
'notInService' or 'destroy' will likely have
consequences up and down the interface stack. Thus,
write access to this object is likely to be
inappropriate for some types of interfaces, and many
implementations will choose not to support write-
access for any type of interface."
::= { ifStackEntry 3 }
ifStackLastChange OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime at the time of the last change
of the (whole) interface stack. A change of the
interface stack is defined to be any creation,
deletion, or change in value of any instance of
ifStackStatus. If the interface stack has been
unchanged since the last re-initialization of the
local network management subsystem, then this object
contains a zero value."
::= { ifMIBObjects 6 }
--
-- The Interface Test Table
--
-- This group of objects is optional. However, a media-specific
-- MIB may make implementation of this group mandatory.
--
-- This table replaces the ifExtnsTestTable
--
ifTestTable OBJECT-TYPE
SYNTAX SEQUENCE OF IfTestEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"This table contains one entry per interface. It
defines objects which allow a network manager to
instruct an agent to test an interface for various
faults. Tests for an interface are defined in the
media-specific MIB for that interface. After invoking
a test, the object ifTestResult can be read to
determine the outcome. If an agent can not perform
the test, ifTestResult is set to so indicate. The
object ifTestCode can be used to provide further
test-specific or interface-specific (or even
enterprise-specific) information concerning the
outcome of the test. Only one test can be in progress
on each interface at any one time. If one test is in
progress when another test is invoked, the second test
is rejected. Some agents may reject a test when a
prior test is active on another interface.
Before starting a test, a manager-station must first
obtain 'ownership' of the entry in the ifTestTable for
the interface to be tested. This is accomplished with
the ifTestId and ifTestStatus objects as follows:
try_again:
get (ifTestId, ifTestStatus)
while (ifTestStatus != notInUse)
/*
* Loop while a test is running or some other
* manager is configuring a test.
*/
short delay
get (ifTestId, ifTestStatus)
}
/*
* Is not being used right now -- let's compete
* to see who gets it.
*/
lock_value = ifTestId
if ( set(ifTestId = lock_value, ifTestStatus = inUse,
ifTestOwner = 'my-IP-address') == FAILURE)
/*
* Another manager got the ifTestEntry -- go
* try again
*/
goto try_again;
/*
* I have the lock
*/
set up any test parameters.
/*
* This starts the test
*/
set(ifTestType = test_to_run);
wait for test completion by polling ifTestResult
when test completes, agent sets ifTestResult
agent also sets ifTestStatus = 'notInUse'
retrieve any additional test results, and ifTestId
if (ifTestId == lock_value+1) results are valid
A manager station first retrieves the value of the
appropriate ifTestId and ifTestStatus objects,
periodically repeating the retrieval if necessary,
until the value of ifTestStatus is 'notInUse'. The
manager station then tries to set the same ifTestId
object to the value it just retrieved, the same
ifTestStatus object to 'inUse', and the corresponding
ifTestOwner object to a value indicating itself. If
the set operation succeeds then the manager has
obtained ownership of the ifTestEntry, and the value of
the ifTestId object is incremented by the agent (per
the semantics of TestAndIncr). Failure of the set
operation indicates that some other manager has
obtained ownership of the ifTestEntry.
Once ownership is obtained, any test parameters can be
setup, and then the test is initiated by setting
ifTestType. On completion of the test, the agent sets
ifTestStatus to 'notInUse'. Once this occurs, the
manager can retrieve the results. In the (rare) event
that the invocation of tests by two network managers
were to overlap, then there would be a possibility that
the first test's results might be overwritten by the
second test's results prior to the first results being
read. This unlikely circumstance can be detected by a
network manager retrieving ifTestId at the same time as
retrieving the test results, and ensuring that the
results are for the desired request.
If ifTestType is not set within an abnormally long
period of time after ownership is obtained, the agent
should time-out the manager, and reset the value of the
ifTestStatus object back to 'notInUse'. It is
suggested that this time-out period be 5 minutes.
In general, a management station must not retransmit a
request to invoke a test for which it does not receive
a response; instead, it properly inspects an agent's
MIB to determine if the invocation was successful.
Only if the invocation was unsuccessful, is the
invocation request retransmitted.
Some tests may require the interface to be taken off-
line in order to execute them, or may even require the
agent to reboot after completion of the test. In these
circumstances, communication with the management
station invoking the test may be lost until after
completion of the test. An agent is not required to
support such tests. However, if such tests are
supported, then the agent should make every effort to
transmit a response to the request which invoked the
test prior to losing communication. When the agent is
restored to normal service, the results of the test are
properly made available in the appropriate objects.
Note that this requires that the ifIndex value assigned
to an interface must be unchanged even if the test
causes a reboot. An agent must reject any test for
which it cannot, perhaps due to resource constraints,
make available at least the minimum amount of
information after that test completes."
::= { ifMIBObjects 3 }
ifTestEntry OBJECT-TYPE
SYNTAX IfTestEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"An entry containing objects for invoking tests on an
interface."
AUGMENTS { ifEntry }
::= { ifTestTable 1 }
IfTestEntry ::=
SEQUENCE {
ifTestId TestAndIncr,
ifTestStatus INTEGER,
ifTestType AutonomousType,
ifTestResult INTEGER,
ifTestCode OBJECT IDENTIFIER,
ifTestOwner OwnerString
}
ifTestId OBJECT-TYPE
SYNTAX TestAndIncr
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"This object identifies the current invocation of the
interface's test."
::= { ifTestEntry 1 }
ifTestStatus OBJECT-TYPE
SYNTAX INTEGER { notInUse(1), inUse(2) }
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"This object indicates whether or not some manager
currently has the necessary 'ownership' required to
invoke a test on this interface. A write to this
object is only successful when it changes its value
from 'notInUse(1)' to 'inUse(2)'. After completion of
a test, the agent resets the value back to
'notInUse(1)'."
::= { ifTestEntry 2 }
ifTestType OBJECT-TYPE
SYNTAX AutonomousType
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"A control variable used to start and stop operator-
initiated interface tests. Most OBJECT IDENTIFIER
values assigned to tests are defined elsewhere, in
association with specific types of interface.
However, this document assigns a value for a full-
duplex loopback test, and defines the special meanings
of the subject identifier:
noTest OBJECT IDENTIFIER ::= { 0 0 }
When the value noTest is written to this object, no
action is taken unless a test is in progress, in which
case the test is aborted. Writing any other value to
this object is only valid when no test is currently in
progress, in which case the indicated test is
initiated.
When read, this object always returns the most recent
value that ifTestType was set to. If it has not been
set since the last initialization of the network
management subsystem on the agent, a value of noTest
is returned."
::= { ifTestEntry 3 }
ifTestResult OBJECT-TYPE
SYNTAX INTEGER {
none(1), -- no test yet requested
success(2),
inProgress(3),
notSupported(4),
unAbleToRun(5), -- due to state of system
aborted(6),
failed(7)
}
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"This object contains the result of the most recently
requested test, or the value none(1) if no tests have
been requested since the last reset. Note that this
facility provides no provision for saving the results
of one test when starting another, as could be
required if used by multiple managers concurrently."
::= { ifTestEntry 4 }
ifTestCode OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"This object contains a code which contains more
specific information on the test result, for example
an error-code after a failed test. Error codes and
other values this object may take are specific to the
type of interface and/or test. The value may have the
semantics of either the AutonomousType or
InstancePointer textual conventions as defined in RFC
1443. The identifier:
testCodeUnknown OBJECT IDENTIFIER ::= { 0 0 }
is defined for use if no additional result code is
available."
::= { ifTestEntry 5 }
ifTestOwner OBJECT-TYPE
SYNTAX OwnerString
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"The entity which currently has the 'ownership'
required to invoke a test on this interface."
::= { ifTestEntry 6 }
-- Generic Receive Address Table
--
-- This group of objects is mandatory for all types of
-- interfaces which can receive packets/frames addressed to
-- more than one address.
--
-- This table replaces the ifExtnsRcvAddr table. The main
-- difference is that this table makes use of the RowStatus
-- textual convention, while ifExtnsRcvAddr did not.
ifRcvAddressTable OBJECT-TYPE
SYNTAX SEQUENCE OF IfRcvAddressEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains an entry for each address
(broadcast, multicast, or uni-cast) for which the
system will receive packets/frames on a particular
interface, except as follows:
- for an interface operating in promiscuous mode,
entries are only required for those addresses for
which the system would receive frames were it not
operating in promiscuous mode.
- for 802.5 functional addresses, only one entry is
required, for the address which has the functional
address bit ANDed with the bit mask of all functional
addresses for which the interface will accept frames."
::= { ifMIBObjects 4 }
ifRcvAddressEntry OBJECT-TYPE
SYNTAX IfRcvAddressEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of objects identifying an address for which
the system will accept packets/frames on the
particular interface identified by the index value
ifIndex."
INDEX { ifIndex, ifRcvAddressAddress }
::= { ifRcvAddressTable 1 }
IfRcvAddressEntry ::=
SEQUENCE {
ifRcvAddressAddress PhysAddress,
ifRcvAddressStatus RowStatus,
ifRcvAddressType INTEGER
}
ifRcvAddressAddress OBJECT-TYPE
SYNTAX PhysAddress
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An address for which the system will accept
packets/frames on this entry's interface."
::= { ifRcvAddressEntry 1 }
ifRcvAddressStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is used to create and delete rows in the
ifRcvAddressTable."
::= { ifRcvAddressEntry 2 }
ifRcvAddressType OBJECT-TYPE
SYNTAX INTEGER {
other(1),
volatile(2),
nonVolatile(3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object has the value nonVolatile(3) for those
entries in the table which are valid and will not be
deleted by the next restart of the managed system.
Entries having the value volatile(2) are valid and
exist, but have not been saved, so that will not exist
after the next restart of the managed system. Entries
having the value other(1) are valid and exist but are
not classified as to whether they will continue to
exist after the next restart."
DEFVAL { volatile }
::= { ifRcvAddressEntry 3 }
-- definition of interface-related traps.
linkDown NOTIFICATION-TYPE
OBJECTS { ifIndex, ifAdminStatus, ifOperStatus }
STATUS current
DESCRIPTION
"A linkDown trap signifies that the SNMPv2 entity,
acting in an agent role, has detected that the
ifOperStatus object for one of its communication links
is about to transition into the down state."
::= { snmpTraps 3 }
linkUp NOTIFICATION-TYPE
OBJECTS { ifIndex, ifAdminStatus, ifOperStatus }
STATUS current
DESCRIPTION
"A linkUp trap signifies that the SNMPv2 entity,
acting in an agent role, has detected that the
ifOperStatus object for one of its communication links
has transitioned out of the down state."
::= { snmpTraps 4 }
-- conformance information
ifConformance OBJECT IDENTIFIER ::= { ifMIB 2 }
ifGroups OBJECT IDENTIFIER ::= { ifConformance 1 }
ifCompliances OBJECT IDENTIFIER ::= { ifConformance 2 }
-- compliance statements
ifCompliance2 MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for SNMPv2 entities which
have network interfaces."
MODULE -- this module
MANDATORY-GROUPS { ifGeneralInformationGroup, ifStackGroup2 }
GROUP ifFixedLengthGroup
DESCRIPTION
"This group is mandatory for all network interfaces
which are character-oriented or transmit data in
fixed-length transmission units."
GROUP ifHCFixedLengthGroup
DESCRIPTION
"This group is mandatory only for those network
interfaces which are character-oriented or transmit
data in fixed-length transmission units, and for which
the value of the corresponding instance of ifSpeed is
greater than 20,000,000 bits/second."
GROUP ifPacketGroup
DESCRIPTION
"This group is mandatory for all network interfaces
which are packet-oriented."
GROUP ifHCPacketGroup
DESCRIPTION
"This group is mandatory only for those network
interfaces which are packet-oriented and for which the
value of the corresponding instance of ifSpeed is
greater than 650,000,000 bits/second."
GROUP ifRcvAddressGroup
DESCRIPTION
"The applicability of this group MUST be defined by
the media-specific MIBs. Media-specific MIBs must
define the exact meaning, use, and semantics of the
addresses in this group."
OBJECT ifLinkUpDownTrapEnable
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT ifPromiscuousMode
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT ifStackStatus
SYNTAX INTEGER { active(1) } -- subset of RowStatus
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required, and only one of the six
enumerated values for the RowStatus textual convention
need be supported, specifically: active(1)."
OBJECT ifAdminStatus
SYNTAX INTEGER { up(1), down(2) }
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required, nor is support for the
value testing(3)."
OBJECT ifAlias
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
::= { ifCompliances 2 }
ifCompliance MODULE-COMPLIANCE
STATUS obsolete
DESCRIPTION
"The compliance statement for SNMPv2 entities which
have network interfaces."
MODULE -- this module
MANDATORY-GROUPS { ifGeneralGroup, ifStackGroup }
GROUP ifFixedLengthGroup
DESCRIPTION
"This group is mandatory for all network interfaces
which are character-oriented or transmit data in
fixed-length transmission units."
GROUP ifHCFixedLengthGroup
DESCRIPTION
"This group is mandatory only for those network
interfaces which are character-oriented or transmit
data in fixed-length transmission units, and for which
the value of the corresponding instance of ifSpeed is
greater than 20,000,000 bits/second."
GROUP ifPacketGroup
DESCRIPTION
"This group is mandatory for all network interfaces
which are packet-oriented."
GROUP ifHCPacketGroup
DESCRIPTION
"This group is mandatory only for those network
interfaces which are packet-oriented and for which the
value of the corresponding instance of ifSpeed is
greater than 650,000,000 bits/second."
GROUP ifTestGroup
DESCRIPTION
"This group is optional. Media-specific MIBs which
require interface tests are strongly encouraged to use
this group for invoking tests and reporting results.
A medium specific MIB which has mandatory tests may
make implementation of this group mandatory."
GROUP ifRcvAddressGroup
DESCRIPTION
"The applicability of this group MUST be defined by
the media-specific MIBs. Media-specific MIBs must
define the exact meaning, use, and semantics of the
addresses in this group."
OBJECT ifLinkUpDownTrapEnable
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT ifPromiscuousMode
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required."
OBJECT ifStackStatus
SYNTAX INTEGER { active(1) } -- subset of RowStatus
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required, and only one of the six
enumerated values for the RowStatus textual convention
need be supported, specifically: active(1)."
OBJECT ifAdminStatus
SYNTAX INTEGER { up(1), down(2) }
MIN-ACCESS read-only
DESCRIPTION
"Write access is not required, nor is support for the
value testing(3)."
::= { ifCompliances 1 }
-- units of conformance
ifGeneralInformationGroup OBJECT-GROUP
OBJECTS { ifIndex, ifDescr, ifType, ifSpeed, ifPhysAddress,
ifAdminStatus, ifOperStatus, ifLastChange,
ifLinkUpDownTrapEnable, ifConnectorPresent,
ifHighSpeed, ifName, ifNumber, ifAlias,
ifTableLastChange }
STATUS current
DESCRIPTION
"A collection of objects providing information
applicable to all network interfaces."
::= { ifGroups 10 }
ifGeneralGroup OBJECT-GROUP
OBJECTS { ifDescr, ifType, ifSpeed, ifPhysAddress,
ifAdminStatus, ifOperStatus, ifLastChange,
ifLinkUpDownTrapEnable, ifConnectorPresent,
ifHighSpeed, ifName }
STATUS obsolete
DESCRIPTION
"A collection of objects providing information
applicable to all network interfaces."
::= { ifGroups 1 }
-- the following five groups are mutually exclusive; at most
-- one of these groups is implemented for any interface
ifFixedLengthGroup OBJECT-GROUP
OBJECTS { ifInOctets, ifOutOctets, ifInUnknownProtos,
ifInErrors, ifOutErrors }
STATUS current
DESCRIPTION
"A collection of objects providing information
specific to non-high speed, character-oriented or
fixed-length-transmission network interfaces. (Non-
high speed interfaces transmit and receive at speeds
less than or equal to 20,000,000 bits/second.)"
::= { ifGroups 2 }
ifHCFixedLengthGroup OBJECT-GROUP
OBJECTS { ifHCInOctets, ifHCOutOctets,
ifInOctets, ifOutOctets, ifInUnknownProtos,
ifInErrors, ifOutErrors }
STATUS current
DESCRIPTION
"A collection of objects providing information
specific to high speed (greater than 20,000,000
bits/second) character-oriented or fixed-length-
transmission network interfaces."
::= { ifGroups 3 }
ifPacketGroup OBJECT-GROUP
OBJECTS { ifInOctets, ifOutOctets, ifInUnknownProtos,
ifInErrors, ifOutErrors,
ifMtu, ifInUcastPkts, ifInMulticastPkts,
ifInBroadcastPkts, ifInDiscards,
ifOutUcastPkts, ifOutMulticastPkts,
ifOutBroadcastPkts, ifOutDiscards,
ifPromiscuousMode }
STATUS current
DESCRIPTION
"A collection of objects providing information
specific to non-high speed, packet-oriented network
interfaces. (Non-high speed interfaces transmit and
receive at speeds less than or equal to 20,000,000
bits/second.)"
::= { ifGroups 4 }
ifHCPacketGroup OBJECT-GROUP
OBJECTS { ifHCInOctets, ifHCOutOctets,
ifInOctets, ifOutOctets, ifInUnknownProtos,
ifInErrors, ifOutErrors,
ifMtu, ifInUcastPkts, ifInMulticastPkts,
ifInBroadcastPkts, ifInDiscards,
ifOutUcastPkts, ifOutMulticastPkts,
ifOutBroadcastPkts, ifOutDiscards,
ifPromiscuousMode }
STATUS current
DESCRIPTION
"A collection of objects providing information
specific to high speed (greater than 20,000,000
bits/second but less than or equal to 650,000,000
bits/second) packet-oriented network interfaces."
::= { ifGroups 5 }
ifVHCPacketGroup OBJECT-GROUP
OBJECTS { ifHCInUcastPkts, ifHCInMulticastPkts,
ifHCInBroadcastPkts, ifHCOutUcastPkts,
ifHCOutMulticastPkts, ifHCOutBroadcastPkts,
ifHCInOctets, ifHCOutOctets,
ifInOctets, ifOutOctets, ifInUnknownProtos,
ifInErrors, ifOutErrors,
ifMtu, ifInUcastPkts, ifInMulticastPkts,
ifInBroadcastPkts, ifInDiscards,
ifOutUcastPkts, ifOutMulticastPkts,
ifOutBroadcastPkts, ifOutDiscards,
ifPromiscuousMode }
STATUS current
DESCRIPTION
"A collection of objects providing information
specific to higher speed (greater than 650,000,000
bits/second) packet-oriented network interfaces."
::= { ifGroups 6 }
ifRcvAddressGroup OBJECT-GROUP
OBJECTS { ifRcvAddressStatus, ifRcvAddressType }
STATUS current
DESCRIPTION
"A collection of objects providing information on the
multiple addresses which an interface receives."
::= { ifGroups 7 }
ifTestGroup OBJECT-GROUP
OBJECTS { ifTestId, ifTestStatus, ifTestType,
ifTestResult, ifTestCode, ifTestOwner }
STATUS obsolete
DESCRIPTION
"A collection of objects providing the ability to
invoke tests on an interface."
::= { ifGroups 8 }
ifStackGroup OBJECT-GROUP
OBJECTS { ifStackStatus }
STATUS obsolete
DESCRIPTION
"A collection of objects providing information on the
layering of MIB-II interfaces."
::= { ifGroups 9 }
ifStackGroup2 OBJECT-GROUP
OBJECTS { ifStackStatus, ifStackLastChange }
STATUS current
DESCRIPTION
"A collection of objects providing information on the
layering of MIB-II interfaces."
::= { ifGroups 11 }
ifOldObjectsGroup OBJECT-GROUP
OBJECTS { ifInNUcastPkts, ifOutNUcastPkts,
ifOutQLen, ifSpecific }
STATUS obsolete
DESCRIPTION
"The collection of objects deprecated from the
original MIB-II interfaces group."
::= { ifGroups 12 }
END