-- Storage Systems
|
|
-- Management Information Base for SNMP Network Management
|
|
--
|
|
--
|
|
-- Copyright 1992,2007 Hewlett-Packard Development Company, L.P.
|
|
-- Hewlett-Packard Company shall not be liable for technical or
|
|
-- editorial errors or omissions contained herein. The information in
|
|
-- this document is provided "as is" without warranty of any kind and
|
|
-- is subject to change without notice. The warranties for HP products
|
|
-- are set forth in the express limited warranty statements
|
|
-- accompanying such products. Nothing herein should be construed as
|
|
-- constituting an additional warranty.
|
|
--
|
|
-- Confidential computer software. Valid license from HP required for
|
|
-- possession, use or copying. Consistent with FAR 12.211 and 12.212,
|
|
-- Commercial Computer Software, Computer Software Documentation, and
|
|
-- Technical Data for Commercial Items are licensed to the U.S.
|
|
-- Government under vendor's standard commercial license.
|
|
--
|
|
-- Refer to the READMIB.RDM file for more information about the
|
|
-- organization of the information in the Compaq Enterprise.
|
|
--
|
|
-- The Compaq Enterprise number is 232.
|
|
-- The ASN.1 prefix to, and including the Compaq Enterprise is:
|
|
-- 1.3.6.1.4.1.232
|
|
--
|
|
-- ****************************************************************************
|
|
|
|
CPQSTSYS-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
compaq FROM CPQHOST-MIB
|
|
-- enterprises FROM RFC1155-SMI
|
|
Counter FROM RFC1155-SMI
|
|
DisplayString FROM RFC1213-MIB
|
|
OBJECT-TYPE FROM RFC-1212
|
|
TRAP-TYPE FROM RFC-1215
|
|
sysName FROM RFC1213-MIB
|
|
cpqHoTrapFlags FROM CPQHOST-MIB;
|
|
|
|
-- compaq OBJECT IDENTIFIER ::= { enterprises 232 }
|
|
|
|
cpqSsStorageSys OBJECT IDENTIFIER ::= { compaq 8 }
|
|
cpqSsMibRev OBJECT IDENTIFIER ::= { cpqSsStorageSys 1 }
|
|
cpqSsDrvBox OBJECT IDENTIFIER ::= { cpqSsStorageSys 2 }
|
|
cpqSsTrap OBJECT IDENTIFIER ::= { cpqSsStorageSys 3 }
|
|
cpqSsRaidSystem OBJECT IDENTIFIER ::= { cpqSsStorageSys 4 }
|
|
cpqSsBoxExtended OBJECT IDENTIFIER ::= { cpqSsDrvBox 2 }
|
|
|
|
-- ****************************************************************************
|
|
-- Storage System MIB Revision
|
|
-- ===========================
|
|
--
|
|
-- The compaq enterprise (1.3.6.1.4.1.232)
|
|
-- cpqSsStorageSys Group (1.3.6.1.4.1.232.8)
|
|
-- cpqSsMibRev Group (1.3.6.1.4.1.232.8.1)
|
|
--
|
|
--
|
|
-- An agent conforming to this document will return a cpqSsMibRevMajor
|
|
-- of one (1) and a cpqSsMibRevMinor of thirty one (31).
|
|
--
|
|
-- Implementation of the MibRev group is mandatory.
|
|
--
|
|
-- ****************************************************************************
|
|
|
|
cpqSsMibRevMajor OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Major Revision level.
|
|
A change in the major revision level represents a major change in
|
|
the architecture of the MIB. A change in the major revision level
|
|
may indicate a significant change in the information supported
|
|
and/or the meaning of the supported information, correct
|
|
interpretation of data may require a MIB document with the same
|
|
major revision level."
|
|
::= { cpqSsMibRev 1 }
|
|
|
|
cpqSsMibRevMinor OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Minor Revision level.
|
|
A change in the minor revision level may represent some minor
|
|
additional support; no changes to any pre-existing information
|
|
has occurred."
|
|
::= { cpqSsMibRev 2 }
|
|
|
|
cpqSsMibCondition OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
ok(2),
|
|
degraded(3),
|
|
failed(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The overall condition (status) of the system represented by
|
|
this MIB."
|
|
::= { cpqSsMibRev 3 }
|
|
|
|
-- ****************************************************************************
|
|
-- Storage System Drive Box Group
|
|
-- ==============================
|
|
--
|
|
-- The compaq enterprise (1.3.6.1.4.1.232)
|
|
-- cpqSsStorageSys Group (1.3.6.1.4.1.232.8)
|
|
-- cpqSsDrvBox Group (1.3.6.1.4.1.232.8.2)
|
|
-- cpqSsDrvBoxTable (1.3.6.1.4.1.232.8.2.1)
|
|
--
|
|
-- Implementation of the Drive Box group is mandatory.
|
|
--
|
|
-- ****************************************************************************
|
|
|
|
cpqSsDrvBoxTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CpqSsDrvBoxEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Drive Box Table."
|
|
::= { cpqSsDrvBox 1 }
|
|
|
|
cpqSsDrvBoxEntry OBJECT-TYPE
|
|
SYNTAX CpqSsDrvBoxEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Drive Box Entry."
|
|
INDEX { cpqSsBoxCntlrIndex, cpqSsBoxBusIndex }
|
|
::= { cpqSsDrvBoxTable 1 }
|
|
|
|
CpqSsDrvBoxEntry ::= SEQUENCE
|
|
{
|
|
cpqSsBoxCntlrIndex INTEGER,
|
|
cpqSsBoxBusIndex INTEGER,
|
|
cpqSsBoxType INTEGER,
|
|
cpqSsBoxModel DisplayString,
|
|
cpqSsBoxFWRev DisplayString,
|
|
cpqSsBoxVendor DisplayString,
|
|
cpqSsBoxFanStatus INTEGER,
|
|
cpqSsBoxCondition INTEGER,
|
|
cpqSsBoxTempStatus INTEGER,
|
|
cpqSsBoxSidePanelStatus INTEGER,
|
|
cpqSsBoxFltTolPwrSupplyStatus INTEGER,
|
|
cpqSsBoxBackPlaneVersion INTEGER,
|
|
cpqSsBoxTotalBays INTEGER,
|
|
cpqSsBoxPlacement INTEGER,
|
|
cpqSsBoxDuplexOption INTEGER,
|
|
cpqSsBoxBoardRevision INTEGER,
|
|
cpqSsBoxSerialNumber DisplayString,
|
|
cpqSsBoxCntlrHwLocation DisplayString,
|
|
cpqSsBoxBackplaneSpeed INTEGER,
|
|
cpqSsBoxConnectionType INTEGER,
|
|
cpqSsBoxHostConnector DisplayString,
|
|
cpqSsBoxBoxOnConnector INTEGER,
|
|
cpqSsBoxLocationString DisplayString
|
|
}
|
|
|
|
cpqSsBoxCntlrIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Drive Box Controller Index.
|
|
|
|
The controller index indicates to which adapter card instance
|
|
this table entry belongs."
|
|
::= { cpqSsDrvBoxEntry 1 }
|
|
|
|
cpqSsBoxBusIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Drive Box Bus Index.
|
|
|
|
The bus index indicates to which bus instance on an adapter card
|
|
this table entry belongs."
|
|
::= { cpqSsDrvBoxEntry 2 }
|
|
|
|
cpqSsBoxType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
other(1),
|
|
proLiant(2),
|
|
proLiant2(3),
|
|
proLiant2Internal(4),
|
|
proLiant2DuplexTop(5),
|
|
proLiant2DuplexBottom(6),
|
|
proLiant2InternalDuplexTop(7),
|
|
proLiant2InternalDuplexBottom(8)
|
|
}
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Drive Box Type.
|
|
|
|
This is the type of drive box. The following types are defined:
|
|
|
|
other(1)
|
|
The agent does not recognize this drive storage system.
|
|
|
|
proLiant(2)
|
|
This is a ProLiant Storage System.
|
|
|
|
proLiant2(3)
|
|
This is a ProLiant-2 Storage System.
|
|
|
|
proLiant2Internal(4)
|
|
This is an internal ProLiant-2 Storage System that is found
|
|
in some servers.
|
|
|
|
proLiant2DuplexTop(5)
|
|
This is the top portion of a ProLiant-2 Storage System that
|
|
has dual SCSI busses which are duplexed.
|
|
|
|
proLiant2DuplexBottom(6)
|
|
This is the bottom portion of a ProLiant-2 Storage System that
|
|
has dual SCSI busses which are duplexed.
|
|
|
|
proLiant2InternalDuplexTop(7)
|
|
This is the top portion of a ProLiant Server into which the
|
|
internal SCSI busses are duplexed.
|
|
|
|
proLiant2InternalDuplexBottom(8)
|
|
This is the bottom portion of a ProLiant Server into which the
|
|
internal SCSI busses are duplexed."
|
|
::= { cpqSsDrvBoxEntry 3 }
|
|
|
|
cpqSsBoxModel OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..17))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Drive Box Model.
|
|
|
|
This is a description of the drive box's model.
|
|
This can be used for identification purposes."
|
|
::= { cpqSsDrvBoxEntry 4 }
|
|
|
|
cpqSsBoxFWRev OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..8))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Drive Box Firmware Revision.
|
|
|
|
This is the revision level of the drive box.
|
|
This can be used for identification purposes."
|
|
::= { cpqSsDrvBoxEntry 5 }
|
|
|
|
cpqSsBoxVendor OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..9))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Drive Box Vendor
|
|
|
|
This is the drive box's vendor name.
|
|
This can be used for identification purposes."
|
|
::= { cpqSsDrvBoxEntry 6 }
|
|
|
|
cpqSsBoxFanStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
other(1),
|
|
ok(2),
|
|
failed(3),
|
|
noFan(4),
|
|
degraded(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Drive Box Fan Status.
|
|
|
|
This is the current status of the fans in the drive box.
|
|
This value will be one of the following:
|
|
other(1)
|
|
Fan monitoring is not supported by this system
|
|
or it is not supported by the driver.
|
|
|
|
ok(2)
|
|
All fans are working normally.
|
|
|
|
failed(3)
|
|
One or more storage system fans have failed. The fan(s) should
|
|
be replaced immediately to avoid hardware damage.
|
|
|
|
noFan(4)
|
|
This unit does not support fan monitoring.
|
|
|
|
degraded(5)
|
|
At least one storage system fan has failed, but there is still
|
|
sufficient cooling capacity to allow the system to continue.
|
|
The fan should be replaced."
|
|
|
|
::= { cpqSsDrvBoxEntry 7 }
|
|
|
|
cpqSsBoxCondition OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
other(1),
|
|
ok(2),
|
|
degraded(3),
|
|
failed(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"SCSI Drive Box Condition.
|
|
|
|
This is the overall condition of the drive box.
|
|
The following values are defined:
|
|
|
|
other(1)
|
|
The agent does not recognize the status. You may need to
|
|
upgrade your software.
|
|
|
|
ok(2)
|
|
The storage system is operating normally. No user
|
|
action is required.
|
|
|
|
degraded(3)
|
|
The storage system is degraded. You need to check the
|
|
temperature status or power supply status of this
|
|
storage system. Additionally, if the side panel for
|
|
the storage system is removed, the air flow changes
|
|
could result in improper cooling of the drives and affect
|
|
the temperature status.
|
|
|
|
failed(4)
|
|
The storage system has failed."
|
|
::= { cpqSsDrvBoxEntry 8 }
|
|
|
|
cpqSsBoxTempStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
other(1),
|
|
ok(2),
|
|
degraded(3),
|
|
failed(4),
|
|
noTemp(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The temperature of the drive system.
|
|
|
|
This value will be one of the following:
|
|
other(1)
|
|
Temperature monitoring is not supported by this system
|
|
or it is not supported by the driver.
|
|
|
|
ok(2)
|
|
The temperature is within normal operating range.
|
|
|
|
degraded(3)
|
|
The temperature is outside of normal operating range.
|
|
|
|
failed(4)
|
|
The temperature could permanently damage the system.
|
|
The storage system will automatically shutdown if this
|
|
condition is detected.
|
|
|
|
noTemp(5)
|
|
This unit does not support temperature monitoring."
|
|
|
|
::= { cpqSsDrvBoxEntry 9 }
|
|
|
|
cpqSsBoxSidePanelStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
other(1),
|
|
sidePanelInPlace(2),
|
|
sidePanelRemoved(3),
|
|
noSidePanelStatus(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Drive Box Side Panel Status.
|
|
|
|
This value will be one of the following:
|
|
other(1)
|
|
The agent does not recognize the status. You may need to
|
|
upgrade your software.
|
|
|
|
sidePanelInPlace(2)
|
|
The side panel is properly installed on the storage system.
|
|
|
|
sidePanelRemoved(3)
|
|
The side panel is not properly installed on the storage system.
|
|
|
|
noSidePanelStatus(4)
|
|
This unit does not support side panel status monitoring."
|
|
|
|
::= { cpqSsDrvBoxEntry 10 }
|
|
|
|
cpqSsBoxFltTolPwrSupplyStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
other(1),
|
|
ok(2),
|
|
degraded(3),
|
|
failed(4),
|
|
noFltTolPower(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This value specifies the overall status of the fault tolerant
|
|
power supply sub-system in a drive box.
|
|
|
|
This value will be one of the following:
|
|
other(1)
|
|
The power supply status cannot be determined.
|
|
|
|
ok(2)
|
|
There are no detected power supply failures.
|
|
|
|
degraded(3)
|
|
One of the power supply units in a fault tolerant power
|
|
supply has failed.
|
|
|
|
failed(4)
|
|
No failure conditions can currently be determined.
|
|
|
|
noFltTolPower(5)
|
|
This unit does not support fault tolerant power supply
|
|
monitoring."
|
|
|
|
::= { cpqSsDrvBoxEntry 11 }
|
|
|
|
cpqSsBoxBackPlaneVersion OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
other(1),
|
|
proLiant(2),
|
|
proLiant2(3),
|
|
proLiant3(4),
|
|
proLiant4(5),
|
|
proLiant5(6)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Drive Box Back Plane Version.
|
|
|
|
This is the version of the drive box back plane. The following
|
|
types are defined:
|
|
|
|
other(1)
|
|
The agent does not recognize this drive storage system back
|
|
plane.
|
|
|
|
proLiant(2)
|
|
This is a ProLiant Storage System.
|
|
|
|
proLiant2(3)
|
|
This is a ProLiant-2 Storage System.
|
|
|
|
proLiant3(4)
|
|
This is a ProLiant-3 Storage System.
|
|
|
|
proLiant4(5)
|
|
This is a 4th generation Proliant Storage System.
|
|
|
|
proLiant5(6)
|
|
This is a 5th generation ProLiant Storage System."
|
|
::= { cpqSsDrvBoxEntry 12 }
|
|
|
|
|
|
cpqSsBoxTotalBays OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Drive Box Total Bays.
|
|
|
|
This is the total number of bays in this storage system."
|
|
::= { cpqSsDrvBoxEntry 13 }
|
|
|
|
|
|
cpqSsBoxPlacement OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
other(1),
|
|
internal(2),
|
|
external(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Drive Box Placement.
|
|
|
|
The following values are defined:
|
|
|
|
other(1)
|
|
The agent is unable to determine if this storage system is
|
|
located internal or external to the system chassis.
|
|
|
|
internal(2)
|
|
The storage system is located in the system chassis.
|
|
|
|
external(3)
|
|
The storage system is located outside the system chassis
|
|
in an expansion box."
|
|
::= { cpqSsDrvBoxEntry 14 }
|
|
|
|
|
|
cpqSsBoxDuplexOption OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
other(1),
|
|
notDuplexed(2),
|
|
duplexTop(3),
|
|
duplexBottom(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Drive Box Duplex Option.
|
|
|
|
The following values are defined:
|
|
|
|
other(1)
|
|
The agent is unable to determine if this storage system is
|
|
duplexed.
|
|
|
|
notDuplexed(2)
|
|
This storage system is not duplexed.
|
|
|
|
duplexTop(3)
|
|
This is the top portion of a duplexed storage system.
|
|
|
|
duplexBottom(4)
|
|
This is the bottom portion of a duplexed storage system."
|
|
::= { cpqSsDrvBoxEntry 15 }
|
|
|
|
cpqSsBoxBoardRevision OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Drive Box Board Revision.
|
|
|
|
This is the board revision of this storage system backplane."
|
|
::= { cpqSsDrvBoxEntry 16 }
|
|
|
|
cpqSsBoxSerialNumber OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..24))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Drive Box Serial Number.
|
|
|
|
This is the drive box's serial number which is normally display
|
|
on the front panel. This can be used for identification
|
|
purposes."
|
|
::= { cpqSsDrvBoxEntry 17 }
|
|
|
|
cpqSsBoxCntlrHwLocation OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A text description of the hardware location of the controller
|
|
to which this box is attached. A NULL string indicates that
|
|
the hardware location could not be determined or is irrelevant."
|
|
::= { cpqSsDrvBoxEntry 18 }
|
|
|
|
cpqSsBoxBackplaneSpeed OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
other(1),
|
|
ultra3(2),
|
|
ultra320(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Drive Box Backplane Speed.
|
|
|
|
The following values are defined:
|
|
|
|
other(1)
|
|
The agent is unable to determine the backplane speed for this
|
|
storage system.
|
|
|
|
ultra3(2)
|
|
This storage system is capable of Ultra3 speeds.
|
|
|
|
ultra320(3)
|
|
This storage system is capable of Ultra320 speeds."
|
|
::= { cpqSsDrvBoxEntry 19 }
|
|
|
|
cpqSsBoxConnectionType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
other(1),
|
|
scsiAttached(2),
|
|
sasAttached(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Drive Box Connection Type.
|
|
|
|
The following values are defined:
|
|
|
|
other(1)
|
|
The agent is unable to determine the type of connection to
|
|
this storage system.
|
|
|
|
scsiAttached(2)
|
|
This storage system is attached to the host via SCSI.
|
|
|
|
sasAttached(3)
|
|
This storage system is attached to the host via SAS."
|
|
::= { cpqSsDrvBoxEntry 20 }
|
|
|
|
cpqSsBoxHostConnector OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..4))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Drive Box Host Connector.
|
|
|
|
This is the host connector to which the drive box is attached.
|
|
If the host connector cannot be determined, the agent will
|
|
return a NULL string."
|
|
::= { cpqSsDrvBoxEntry 21 }
|
|
|
|
cpqSsBoxBoxOnConnector OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Drive Box, Box on Connector.
|
|
|
|
The box on connector indicates which box instance this table
|
|
entry belongs. The instances start at one and increment for
|
|
each box attached to a connector. If the value cannot be
|
|
determined or does not apply, -1 is returned."
|
|
::= { cpqSsDrvBoxEntry 22 }
|
|
|
|
cpqSsBoxLocationString OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Drive Box Location String.
|
|
|
|
This string describes the location of the drive box in relation
|
|
to the controller to which it is attached. If the location
|
|
string cannot be determined, the agent will return a NULL string."
|
|
::= { cpqSsDrvBoxEntry 23 }
|
|
|
|
|
|
-- ****************************************************************************
|
|
-- Storage System Chassis Group
|
|
-- ============================
|
|
--
|
|
-- The compaq enterprise (1.3.6.1.4.1.232)
|
|
-- cpqSsStorageSys Group (1.3.6.1.4.1.232.8)
|
|
-- cpqSsDrvBox Group (1.3.6.1.4.1.232.8.2)
|
|
-- cpqSsBoxExtended Group (1.3.6.1.4.1.232.8.2.2)
|
|
-- cpqSsChassisTable (1.3.6.1.4.1.232.8.2.2.1)
|
|
--
|
|
-- ****************************************************************************
|
|
|
|
cpqSsChassisTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CpqSsChassisEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System Chassis Table."
|
|
::= { cpqSsBoxExtended 1 }
|
|
|
|
cpqSsChassisEntry OBJECT-TYPE
|
|
SYNTAX CpqSsChassisEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System Chassis Entry."
|
|
INDEX { cpqSsChassisIndex }
|
|
::= { cpqSsChassisTable 1 }
|
|
|
|
CpqSsChassisEntry ::= SEQUENCE
|
|
{
|
|
cpqSsChassisIndex INTEGER,
|
|
cpqSsChassisConnectionType INTEGER,
|
|
cpqSsChassisSerialNumber DisplayString,
|
|
cpqSsChassisName DisplayString,
|
|
cpqSsChassisSystemBoardSerNum DisplayString,
|
|
cpqSsChassisSystemBoardRev DisplayString,
|
|
cpqSsChassisPowerBoardSerNum DisplayString,
|
|
cpqSsChassisPowerBoardRev DisplayString,
|
|
cpqSsChassisScsiBoardSerNum DisplayString,
|
|
cpqSsChassisScsiBoardRev DisplayString,
|
|
cpqSsChassisOverallCondition INTEGER,
|
|
cpqSsChassisPowerSupplyCondition INTEGER,
|
|
cpqSsChassisFanCondition INTEGER,
|
|
cpqSsChassisTemperatureCondition INTEGER,
|
|
cpqSsChassisFcaCntlrCondition INTEGER,
|
|
cpqSsChassisFcaLogicalDriveCondition INTEGER,
|
|
cpqSsChassisFcaPhysDrvCondition INTEGER,
|
|
cpqSsChassisTime INTEGER,
|
|
cpqSsChassisModel INTEGER,
|
|
cpqSsChassisBackplaneCondition INTEGER,
|
|
cpqSsChassisFcaTapeDrvCondition INTEGER,
|
|
cpqSsChassisRsoStatus INTEGER,
|
|
cpqSsChassisRsoCondition INTEGER,
|
|
cpqSsChassisScsiIoModuleType INTEGER,
|
|
cpqSsChassisPreferredPathMode INTEGER,
|
|
cpqSsChassisProductId DisplayString
|
|
}
|
|
|
|
cpqSsChassisIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System Chassis Index.
|
|
|
|
The chassis index uniquely identifies a storage system chassis."
|
|
::= { cpqSsChassisEntry 1 }
|
|
|
|
cpqSsChassisConnectionType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
other(1),
|
|
fibreAttached(2),
|
|
scsiAttached(3),
|
|
iScsiAttached(4),
|
|
sasAttached(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System Chassis Connection Type.
|
|
|
|
The following values are defined:
|
|
|
|
other(1)
|
|
The agent is unable to determine the type of connection to
|
|
this chassis.
|
|
|
|
fibreAttached(2)
|
|
This chassis is attached to the server via Fibre Channel.
|
|
|
|
scsiAttached(3)
|
|
This chassis is attached to the server via SCSI.
|
|
|
|
iScsiAttached(4)
|
|
This chassis is attached to the server via iSCSI.
|
|
|
|
sasAttached(5)
|
|
This chassis is attached to the server via SAS."
|
|
::= { cpqSsChassisEntry 2 }
|
|
|
|
cpqSsChassisSerialNumber OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..32))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System Chassis Serial Number.
|
|
|
|
This is the storage system chassis's serial number which is normally
|
|
displayed on the front panel. This can be used for identification
|
|
purposes."
|
|
::= { cpqSsChassisEntry 3 }
|
|
|
|
cpqSsChassisName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..32))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System Chassis Name.
|
|
|
|
This is a user defined name for this storage system chassis."
|
|
::= { cpqSsChassisEntry 4 }
|
|
|
|
cpqSsChassisSystemBoardSerNum OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..24))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System Chassis System Controller Board Serial Number.
|
|
|
|
This is the system controller board's serial number. This can be
|
|
used for identification purposes."
|
|
::= { cpqSsChassisEntry 5 }
|
|
|
|
cpqSsChassisSystemBoardRev OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..8))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System Chassis System Controller Board Revision.
|
|
|
|
This is the system controller board revision."
|
|
::= { cpqSsChassisEntry 6 }
|
|
|
|
cpqSsChassisPowerBoardSerNum OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..24))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System Chassis Power Backplane Board Serial Number.
|
|
|
|
This is the power backplane board's serial number. This can be used
|
|
for identification purposes."
|
|
::= { cpqSsChassisEntry 7 }
|
|
|
|
cpqSsChassisPowerBoardRev OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..8))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System Chassis Power Backplane Board Revision.
|
|
|
|
This is the power backplane board revision."
|
|
::= { cpqSsChassisEntry 8 }
|
|
|
|
cpqSsChassisScsiBoardSerNum OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..24))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System Chassis SCSI Drive Backplane Board Serial
|
|
Number.
|
|
|
|
This is the SCSI drive backplane board's serial number. This can be
|
|
used for identification purposes."
|
|
::= { cpqSsChassisEntry 9 }
|
|
|
|
cpqSsChassisScsiBoardRev OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..8))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System Chassis SCSI Drive Backplane Board Revision.
|
|
|
|
This is the SCSI drive backplane board revision."
|
|
::= { cpqSsChassisEntry 10 }
|
|
|
|
cpqSsChassisOverallCondition OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
other(1),
|
|
ok(2),
|
|
degraded(3),
|
|
failed(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System Chassis Overall Condition.
|
|
|
|
This is the condition of the storage system chassis and all of its
|
|
components. The following values are defined:
|
|
|
|
other(1)
|
|
The agent does not recognize the status. You may need to
|
|
upgrade your software.
|
|
|
|
ok(2)
|
|
The storage system is operating normally. No user
|
|
action is required.
|
|
|
|
degraded(3)
|
|
The storage system chassis is degraded.
|
|
|
|
failed(4)
|
|
The storage system chassis is failed."
|
|
::= { cpqSsChassisEntry 11 }
|
|
|
|
cpqSsChassisPowerSupplyCondition OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
other(1),
|
|
ok(2),
|
|
degraded(3),
|
|
failed(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System Power Supply Condition.
|
|
|
|
This is the aggregate condition of all power supplies in
|
|
the storage system chassis. The following values are defined:
|
|
|
|
other(1)
|
|
The agent does not recognize the status. You may need to
|
|
upgrade your software.
|
|
|
|
ok(2)
|
|
All power supplies are operating normally.
|
|
|
|
degraded(3)
|
|
At least one power supply is degraded or failed.
|
|
|
|
failed(4)
|
|
All power supplies are failed."
|
|
::= { cpqSsChassisEntry 12 }
|
|
|
|
cpqSsChassisFanCondition OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
other(1),
|
|
ok(2),
|
|
degraded(3),
|
|
failed(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System Fan Condition.
|
|
|
|
This is the aggregate condition of all fan modules in the
|
|
storage system chassis. The following values are defined:
|
|
|
|
other(1)
|
|
The agent does not recognize the status. You may need to
|
|
upgrade your software.
|
|
|
|
ok(2)
|
|
All fan modules are operating normally.
|
|
|
|
degraded(3)
|
|
At least one fan module is degraded.
|
|
|
|
failed(4)
|
|
At least one fan module is failed."
|
|
::= { cpqSsChassisEntry 13 }
|
|
|
|
cpqSsChassisTemperatureCondition OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
other(1),
|
|
ok(2),
|
|
degraded(3),
|
|
failed(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System Temperature Condition.
|
|
|
|
This is the aggregate condition of all the temperatur sensors
|
|
in the storage system chassis. The following values are defined:
|
|
|
|
other(1)
|
|
The agent does not recognize the status. You may need to
|
|
upgrade your software.
|
|
|
|
ok(2)
|
|
All temperature sensors are reading within normal limits.
|
|
|
|
degraded(3)
|
|
At least one temperature sensor is reading degraded.
|
|
|
|
failed(4)
|
|
At least one temperature sensor is reading failed."
|
|
::= { cpqSsChassisEntry 14 }
|
|
|
|
cpqSsChassisFcaCntlrCondition OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
other(1),
|
|
ok(2),
|
|
degraded(3),
|
|
failed(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System Fibre Channel Array Controller Condition.
|
|
|
|
This is the aggregate condition of all Fibre Channel Array controllers
|
|
in the storage system chassis. The following values are defined:
|
|
|
|
other(1)
|
|
The condition cannot be determined or is not supported on
|
|
this storage system.
|
|
|
|
ok(2)
|
|
All Fibre Channel Array Controllers are operating normally.
|
|
|
|
degraded(3)
|
|
At least one Fibre Channel Array Controller is degraded or
|
|
failed.
|
|
|
|
failed(4)
|
|
All Fibre Channel Array Controllers are failed."
|
|
::= { cpqSsChassisEntry 15 }
|
|
|
|
cpqSsChassisFcaLogicalDriveCondition OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
other(1),
|
|
ok(2),
|
|
degraded(3),
|
|
failed(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System Fibre Channel Array Logical Drive Condition.
|
|
|
|
This is the aggregate condition of all Fibre Channel Array Logical
|
|
Drives in this storage system chassis.
|
|
The following values are defined:
|
|
|
|
other(1)
|
|
The condition cannot be determined or is not supported on
|
|
this storage system.
|
|
|
|
ok(2)
|
|
All Fibre Channel Array Controllers Logical Drives are
|
|
operating normally.
|
|
|
|
degraded(3)
|
|
At least one Fibre Channel Array Controller Logical Drive
|
|
is degraded.
|
|
|
|
failed(4)
|
|
At least one Fibre Channel Array Controller Logical Drive
|
|
is failed."
|
|
::= { cpqSsChassisEntry 16 }
|
|
|
|
cpqSsChassisFcaPhysDrvCondition OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
other(1),
|
|
ok(2),
|
|
degraded(3),
|
|
failed(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System Fibre Channel Array Physical Drive Condition.
|
|
|
|
This is the aggregate condition of all Fibre Channel Array Physical
|
|
Drives in this storage system chassis.
|
|
The following values are defined:
|
|
|
|
other(1)
|
|
The condition cannot be determined or is not supported on
|
|
this storage system.
|
|
|
|
ok(2)
|
|
All Fibre Channel Array Controllers Physical Drives are
|
|
operating normally.
|
|
|
|
degraded(3)
|
|
At least one Fibre Channel Array Controller Physical Drive
|
|
is degraded.
|
|
|
|
failed(4)
|
|
At least one Fibre Channel Array Controller Physical Drive
|
|
is failed."
|
|
::= { cpqSsChassisEntry 17 }
|
|
|
|
cpqSsChassisTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System Chassis Time.
|
|
|
|
This is the storage system chassis's time in tenths of seconds.
|
|
If the chassis time is not supported, the agent will return 0."
|
|
::= { cpqSsChassisEntry 18 }
|
|
|
|
cpqSsChassisModel OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
other(1),
|
|
ra4x00(2),
|
|
msa1000(3),
|
|
smartArrayClusterStorage(4),
|
|
enterpriseModularArray(5),
|
|
enterpriseVirtualArray(6),
|
|
msa500G2(7),
|
|
msa20(8),
|
|
msa1500cs(9),
|
|
msa1510i(10)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System Chassis Model.
|
|
|
|
The following values are defined:
|
|
|
|
other(1)
|
|
The agent is unable to determine the model of this chassis.
|
|
|
|
ra4x00(2)
|
|
Compaq StorageWorks RAID Array 4000/4100.
|
|
|
|
msa1000(3)
|
|
Compaq StorageWorks Modular Smart Array 1000.
|
|
|
|
smartArrayClusterStorage(4)
|
|
HP StorageWorks Modular Smart Array 500
|
|
(Formerly Smart Array Cluster Storage).
|
|
|
|
enterpriseModularArray(5)
|
|
Compaq StorageWorks Enterprise/Modular RAID Array.
|
|
|
|
enterpriseVirtualArray(6)
|
|
Compaq StorageWorks Enterprise Virtual Array.
|
|
|
|
msa500G2(7)
|
|
HP StorageWorks Modular Smart Array 500 G2.
|
|
|
|
msa20(8)
|
|
HP StorageWorks Modular Smart Array 20.
|
|
|
|
msa1500cs(9)
|
|
HP StorageWorks Modular Smart Array 1500 CS.
|
|
|
|
msa1510i(10)
|
|
HP StorageWorks Modular Smart Array 1510i.
|
|
|
|
Reserved(11)
|
|
|
|
Reserved(12)"
|
|
::= { cpqSsChassisEntry 19 }
|
|
|
|
cpqSsChassisBackplaneCondition OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
other(1),
|
|
ok(2),
|
|
degraded(3),
|
|
failed(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System Backplane Condition.
|
|
|
|
This is the aggregate condition of all the backplanes for the
|
|
storage system chassis. The following values are defined:
|
|
|
|
other(1)
|
|
The agent does not recognize the status. You may need to
|
|
upgrade your software.
|
|
|
|
ok(2)
|
|
All backplanes are operating normally.
|
|
|
|
degraded(3)
|
|
At least one storage system is degraded.
|
|
|
|
failed(4)
|
|
At least one storage system is failed."
|
|
::= { cpqSsChassisEntry 20 }
|
|
|
|
cpqSsChassisFcaTapeDrvCondition OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
other(1),
|
|
ok(2),
|
|
degraded(3),
|
|
failed(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System Array Tape Drive Condition.
|
|
|
|
This is the aggregate condition of all tape drives in this storage
|
|
system chassis.
|
|
The following values are defined:
|
|
|
|
other(1)
|
|
The condition cannot be determined or is not supported on
|
|
this storage system.
|
|
|
|
ok(2)
|
|
All tape drives are operating normally.
|
|
|
|
degraded(3)
|
|
At least one tape drive is degraded.
|
|
|
|
failed(4)
|
|
At least one tape drive is failed."
|
|
::= { cpqSsChassisEntry 21 }
|
|
|
|
cpqSsChassisRsoStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
other(1),
|
|
notSupported(2),
|
|
notConfigured(3),
|
|
disabled(4),
|
|
daemonDownDisabled(5),
|
|
ok(6),
|
|
daemonDownActive(7),
|
|
noSecondary(8),
|
|
daemonDownNoSecondary(9),
|
|
linkDown(10),
|
|
daemonDownLinkDown(11),
|
|
secondaryRunningAuto(12),
|
|
secondaryRunningUser(13),
|
|
evTimeoutError(14)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System Chassis Recovery Server Option Status.
|
|
|
|
The following values are defined:
|
|
|
|
other(1)
|
|
The recovery server option status cannot be determined for
|
|
this storage system.
|
|
|
|
notSupported(2)
|
|
The recovery server option is not supported for this storage
|
|
system.
|
|
|
|
notConfigured(3)
|
|
The recovery server option is supported, but is not
|
|
configured on this storage system.
|
|
|
|
disabled(4)
|
|
The recovery server option is configured as primary, but
|
|
has been disabled by software.
|
|
|
|
daemonDownDisabled(5)
|
|
The recovery server option operating system daemon is no
|
|
longer running. The last status of RSO was disabled(4).
|
|
|
|
ok(6)
|
|
The recovery server option is configured as primary and
|
|
everything is working correctly.
|
|
|
|
daemonDownActive(7)
|
|
The recovery server option operating system daemon is no
|
|
longer running. The last status of RSO was ok(6).
|
|
|
|
noSecondary(8)
|
|
The recovery server option is configured as primary, but
|
|
communication with the standby server has not been established.
|
|
|
|
daemonDownNoSecondary(9)
|
|
The recovery server option operating system daemon is no
|
|
longer running. The last status of RSO was noSecondary(8).
|
|
|
|
linkDown(10)
|
|
The recovery server option is configured as primary, but
|
|
communication with the standby server has failed.
|
|
|
|
daemonDownLinkDown(11)
|
|
The recovery server option operating system daemon is no
|
|
longer running. The last status of RSO was linkDown(10).
|
|
|
|
secondaryRunningAuto(12)
|
|
The recovery server option is configured and the standby
|
|
server is running. The secondary server assumed control
|
|
after communication with the primary server failed.
|
|
|
|
secondaryRunningUser(13)
|
|
The recovery server option is configured and the standby
|
|
server is running. A user forced the secondary server to
|
|
assume control.
|
|
|
|
evTimeoutError(14)
|
|
The recovery server option environment variable cannot be
|
|
accessed."
|
|
::= { cpqSsChassisEntry 22 }
|
|
|
|
cpqSsChassisRsoCondition OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
other(1),
|
|
ok(2),
|
|
degraded(3),
|
|
failed(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System Chassis Recovery Server Option Condition.
|
|
|
|
This is the condition of the recovery server option. The
|
|
following values are defined:
|
|
|
|
other(1)
|
|
The agent does not recognize the status. You may need to
|
|
upgrade your software.
|
|
|
|
ok(2)
|
|
The recovery server option is operating normally. No user
|
|
action is required.
|
|
|
|
degraded(3)
|
|
The recovery server option is degraded.
|
|
|
|
failed(4)
|
|
The recovery server option is failed."
|
|
::= { cpqSsChassisEntry 23 }
|
|
|
|
cpqSsChassisScsiIoModuleType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
other(1),
|
|
io2port(2),
|
|
io4portUpgradeFirmware(3),
|
|
io4port(4),
|
|
io2port320(5),
|
|
io4port320(6),
|
|
io1port320(7)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System Chassis SCSI I/O Module Type.
|
|
|
|
The following values are defined:
|
|
|
|
other(1)
|
|
The agent does not recognize SCSI I/O module type. You may
|
|
need to upgrade your software.
|
|
|
|
io2port(2)
|
|
A 2-Port Ultra3 SCSI I/O Module is installed.
|
|
|
|
io4portUpgradeFirmware(3)
|
|
A 4-Port Shared Storage Module for Smart Array Cluster Storage
|
|
is installed, but the current controller firmware does not
|
|
support it. Upgrade your controller firmware.
|
|
|
|
io4port(4)
|
|
A 4-Port Shared Storage Module for Smart Array Cluster Storage
|
|
is installed.
|
|
|
|
io2port320(5)
|
|
A 2-Port Ultra320 SCSI I/O Module is installed.
|
|
|
|
io4port320(6)
|
|
A 4-Port Ultra320 SCSI I/O Module is installed.
|
|
|
|
io1port320(7)
|
|
A 1-Port Ultra320 SCSI I/O Module is installed."
|
|
::= { cpqSsChassisEntry 24 }
|
|
|
|
cpqSsChassisPreferredPathMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
other(1),
|
|
notActiveActive(2),
|
|
automatic(3),
|
|
manual(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Array Controller Preferred Path Mode.
|
|
|
|
This is the storage system active/active preferred path mode.
|
|
The following values are valid:
|
|
|
|
other (1)
|
|
Indicates that the agent does not recognize the preferred path
|
|
mode of the storage system. You may need to upgrade the agent.
|
|
|
|
notActiveActive (2)
|
|
The storage system is not configured as active/active.
|
|
|
|
automatic (3)
|
|
The storage system automatically selects the preferred path
|
|
for each logical drive based on host I/O patterns.
|
|
|
|
manual (4)
|
|
The preferred path for each logical drive is manually
|
|
configured by the storage system administrator."
|
|
::= { cpqSsChassisEntry 25 }
|
|
|
|
cpqSsChassisProductId OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..32))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System Chassis Product Identifier.
|
|
|
|
This is the storage system chassis's product identifier. This can
|
|
be used for identification purposes. If the product identifier can
|
|
not be determined, the agent will return a NULL string."
|
|
::= { cpqSsChassisEntry 26 }
|
|
|
|
|
|
-- ****************************************************************************
|
|
-- Storage System I/O Slot Table
|
|
-- =============================
|
|
--
|
|
-- The compaq enterprise (1.3.6.1.4.1.232)
|
|
-- cpqSsStorageSys Group (1.3.6.1.4.1.232.8)
|
|
-- cpqSsDrvBox Group (1.3.6.1.4.1.232.8.2)
|
|
-- cpqSsBoxExtended Group (1.3.6.1.4.1.232.8.2.2)
|
|
-- cpqSsIoSlotTable (1.3.6.1.4.1.232.8.2.2.2)
|
|
--
|
|
-- ****************************************************************************
|
|
|
|
cpqSsIoSlotTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CpqSsIoSlotEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System I/O Slot Table."
|
|
::= { cpqSsBoxExtended 2 }
|
|
|
|
cpqSsIoSlotEntry OBJECT-TYPE
|
|
SYNTAX CpqSsIoSlotEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System I/O Slot Entry."
|
|
INDEX { cpqSsIoSlotChassisIndex, cpqSsIoSlotIndex }
|
|
::= { cpqSsIoSlotTable 1 }
|
|
|
|
CpqSsIoSlotEntry ::= SEQUENCE
|
|
{
|
|
cpqSsIoSlotChassisIndex INTEGER,
|
|
cpqSsIoSlotIndex INTEGER,
|
|
cpqSsIoSlotControllerType INTEGER
|
|
}
|
|
|
|
cpqSsIoSlotChassisIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System I/O Slot Chassis Index.
|
|
|
|
The chassis index uniquely identifies a storage system chassis."
|
|
::= { cpqSsIoSlotEntry 1 }
|
|
|
|
cpqSsIoSlotIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System I/O Slot Index.
|
|
|
|
This index uniquely identifies a storage system I/O Slot."
|
|
::= { cpqSsIoSlotEntry 2 }
|
|
|
|
cpqSsIoSlotControllerType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
other(1),
|
|
notInstalled(2),
|
|
unknownBoard(3),
|
|
fibreArray(4),
|
|
scsiArray(5),
|
|
noSlot(6),
|
|
iScsiArray(7),
|
|
sasArray(8)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System I/O Slot Controller Type.
|
|
|
|
The following values are defined:
|
|
|
|
other(1)
|
|
The agent is unable to determine if anything is installed in
|
|
this storage system I/O slot.
|
|
|
|
notInstalled(2)
|
|
Nothing is installed in this storage system I/O slot.
|
|
|
|
unknownBoardInstalled(3)
|
|
An unknown controller is installed in this storage system
|
|
I/O slot.
|
|
|
|
fibreArray(4)
|
|
A Fibre Channel Array controller is installed in this storage
|
|
system I/O slot.
|
|
|
|
scsiArray(5)
|
|
A SCSI Array controller is installed in this storage system
|
|
I/O slot.
|
|
|
|
noSlot(6)
|
|
The slot does not exist on this chassis.
|
|
|
|
iScsiArray(7)
|
|
An iSCSI Array controller is installed in this storage system
|
|
I/O slot.
|
|
|
|
sasArray(8)
|
|
A SAS Array controller is installed in this storage system
|
|
I/O slot."
|
|
::= { cpqSsIoSlotEntry 3 }
|
|
|
|
|
|
-- ****************************************************************************
|
|
-- Storage System Power Supply Table
|
|
-- =================================
|
|
--
|
|
-- The compaq enterprise (1.3.6.1.4.1.232)
|
|
-- cpqSsStorageSys Group (1.3.6.1.4.1.232.8)
|
|
-- cpqSsDrvBox Group (1.3.6.1.4.1.232.8.2)
|
|
-- cpqSsBoxExtended Group (1.3.6.1.4.1.232.8.2.2)
|
|
-- cpqSsPowerSupplyTable (1.3.6.1.4.1.232.8.2.2.3)
|
|
--
|
|
-- ****************************************************************************
|
|
|
|
cpqSsPowerSupplyTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CpqSsPowerSupplyEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System Power Supply Table."
|
|
::= { cpqSsBoxExtended 3 }
|
|
|
|
cpqSsPowerSupplyEntry OBJECT-TYPE
|
|
SYNTAX CpqSsPowerSupplyEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System Power Supply Entry."
|
|
INDEX { cpqSsPowerSupplyChassisIndex, cpqSsPowerSupplyIndex }
|
|
::= { cpqSsPowerSupplyTable 1 }
|
|
|
|
CpqSsPowerSupplyEntry ::= SEQUENCE
|
|
{
|
|
cpqSsPowerSupplyChassisIndex INTEGER,
|
|
cpqSsPowerSupplyIndex INTEGER,
|
|
cpqSsPowerSupplyBay INTEGER,
|
|
cpqSsPowerSupplyStatus INTEGER,
|
|
cpqSsPowerSupplyUpsStatus INTEGER,
|
|
cpqSsPowerSupplyCondition INTEGER,
|
|
cpqSsPowerSupplySerialNumber DisplayString,
|
|
cpqSsPowerSupplyBoardRevision DisplayString,
|
|
cpqSsPowerSupplyFirmwareRevision DisplayString
|
|
}
|
|
|
|
cpqSsPowerSupplyChassisIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System Power Supply Chassis Index.
|
|
|
|
The chassis index uniquely identifies a storage system chassis."
|
|
::= { cpqSsPowerSupplyEntry 1 }
|
|
|
|
cpqSsPowerSupplyIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System Power Supply Bay.
|
|
|
|
This index uniquely identifies a power supply bay."
|
|
::= { cpqSsPowerSupplyEntry 2 }
|
|
|
|
cpqSsPowerSupplyBay OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
other(1),
|
|
powerBay1(2),
|
|
powerBay2(3),
|
|
composite(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System Power Supply Bay.
|
|
|
|
The following values are defined:
|
|
|
|
other(1)
|
|
The agent does not recognize the bay. You may need to upgrade
|
|
your software.
|
|
|
|
powerBay1(2)
|
|
The power supply is installed in the first power supply bay.
|
|
|
|
powerBay2(3)
|
|
The power supply is installed in the second power supply bay.
|
|
|
|
composite(4)
|
|
The power supply information is a composite of all power
|
|
supplies in the storage system."
|
|
::= { cpqSsPowerSupplyEntry 3 }
|
|
|
|
cpqSsPowerSupplyStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
other(1),
|
|
notInstalled(2),
|
|
ok(3),
|
|
failed(4),
|
|
degraded(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System Power Supply Status.
|
|
|
|
The following values are defined:
|
|
|
|
other(1)
|
|
The agent is unable to determine if this storage system power
|
|
supply bay is occupied.
|
|
|
|
notInstalled(2)
|
|
Nothing is installed in this power supply bay.
|
|
|
|
ok(3)
|
|
A power supply is installed and operating normally.
|
|
|
|
failed(4)
|
|
A power supply is installed and is no longer operating.
|
|
Replace the power supply.
|
|
|
|
degraded(5)
|
|
For composite power supplies, this indicates that at least one
|
|
power supply has failed or lost power."
|
|
::= { cpqSsPowerSupplyEntry 4 }
|
|
|
|
cpqSsPowerSupplyUpsStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
other(1),
|
|
noUps(2),
|
|
ok(3),
|
|
powerFailed(4),
|
|
batteryLow(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System Power Supply Uninterruptible Power Supply (UPS)
|
|
Status.
|
|
|
|
The following values are defined:
|
|
|
|
other(1)
|
|
The agent is unable to determine if this power supply is
|
|
attached to an Uninterruptible Power Supply (UPS).
|
|
|
|
noUps(2)
|
|
No UPS is attached to the power supply.
|
|
|
|
ok(3)
|
|
A UPS is attached to the power supply and is operating
|
|
normally.
|
|
|
|
powerFailed(4)
|
|
A UPS is attached to the power supply and the AC power has
|
|
failed.
|
|
|
|
batteryLow(5)
|
|
A UPS is attached to the power supply, the AC power has
|
|
failed and the UPS battery is low."
|
|
::= { cpqSsPowerSupplyEntry 5 }
|
|
|
|
cpqSsPowerSupplyCondition OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
other(1),
|
|
ok(2),
|
|
degraded(3),
|
|
failed(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System Power Supply Condition.
|
|
|
|
This is the condition of the storage system chassis and all of
|
|
its components. The following values are defined:
|
|
|
|
other(1)
|
|
The agent does not recognize the status. You may need to
|
|
upgrade your software.
|
|
|
|
ok(2)
|
|
The power supply is operating normally. No user action is
|
|
required.
|
|
|
|
degraded(3)
|
|
The power supply is degraded. You need to check the power
|
|
supply or its attached UPS for problems.
|
|
|
|
failed(4)
|
|
The power supply has failed."
|
|
::= { cpqSsPowerSupplyEntry 6 }
|
|
|
|
cpqSsPowerSupplySerialNumber OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..24))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System Power Supply Serial Number.
|
|
|
|
This is the power supply's serial number. This can be used
|
|
for identification purposes. If the serial number is not supported,
|
|
the agent will return a NULL string."
|
|
::= { cpqSsPowerSupplyEntry 7 }
|
|
|
|
cpqSsPowerSupplyBoardRevision OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..8))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System Power Supply Board Revision.
|
|
|
|
This is the power supply board revision. If the board revision is
|
|
not supported, the agent will return a NULL string."
|
|
::= { cpqSsPowerSupplyEntry 8 }
|
|
|
|
cpqSsPowerSupplyFirmwareRevision OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..8))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System Power Supply Firmware Revision.
|
|
|
|
This is the power supply firmware revision. If the firmware revision
|
|
is not supported, the agent will return a NULL string."
|
|
::= { cpqSsPowerSupplyEntry 9 }
|
|
|
|
|
|
-- ****************************************************************************
|
|
-- Storage System Fan Module Table
|
|
-- ===============================
|
|
--
|
|
-- The compaq enterprise (1.3.6.1.4.1.232)
|
|
-- cpqSsStorageSys Group (1.3.6.1.4.1.232.8)
|
|
-- cpqSsDrvBox Group (1.3.6.1.4.1.232.8.2)
|
|
-- cpqSsBoxExtended Group (1.3.6.1.4.1.232.8.2.2)
|
|
-- cpqSsFanModuleTable (1.3.6.1.4.1.232.8.2.2.4)
|
|
--
|
|
-- ****************************************************************************
|
|
|
|
cpqSsFanModuleTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CpqSsFanModuleEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System Fan Module Table."
|
|
::= { cpqSsBoxExtended 4 }
|
|
|
|
cpqSsFanModuleEntry OBJECT-TYPE
|
|
SYNTAX CpqSsFanModuleEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System Fan Module Entry."
|
|
INDEX { cpqSsFanModuleChassisIndex, cpqSsFanModuleIndex }
|
|
::= { cpqSsFanModuleTable 1 }
|
|
|
|
CpqSsFanModuleEntry ::= SEQUENCE
|
|
{
|
|
cpqSsFanModuleChassisIndex INTEGER,
|
|
cpqSsFanModuleIndex INTEGER,
|
|
cpqSsFanModuleStatus INTEGER,
|
|
cpqSsFanModuleCondition INTEGER,
|
|
cpqSsFanModuleLocation INTEGER,
|
|
cpqSsFanModuleSerialNumber DisplayString,
|
|
cpqSsFanModuleBoardRevision DisplayString
|
|
}
|
|
|
|
cpqSsFanModuleChassisIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System Fan Module Chassis Index.
|
|
|
|
The chassis index uniquely identifies a storage system chassis."
|
|
::= { cpqSsFanModuleEntry 1 }
|
|
|
|
cpqSsFanModuleIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System Fan Module Index.
|
|
|
|
This index uniquely identifies a storage system fan module."
|
|
::= { cpqSsFanModuleEntry 2 }
|
|
|
|
cpqSsFanModuleStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
other(1),
|
|
notInstalled(2),
|
|
ok(3),
|
|
degraded(4),
|
|
failed(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System Fan Module Status.
|
|
|
|
The following values are defined:
|
|
|
|
other(1)
|
|
The agent is unable to determine if this storage system fan
|
|
module is installed.
|
|
|
|
notInstalled(3)
|
|
The fan module is not installed.
|
|
|
|
ok(2)
|
|
The fan module is installed and operating normally.
|
|
|
|
degraded(4)
|
|
The fan module degraded.
|
|
|
|
failed(5)
|
|
The fan module is failed. Replace the fan module."
|
|
::= { cpqSsFanModuleEntry 3 }
|
|
|
|
cpqSsFanModuleCondition OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
other(1),
|
|
ok(2),
|
|
degraded(3),
|
|
failed(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System Fan Module Condition.
|
|
|
|
This is the condition of the storage system fan module.
|
|
The following values are defined:
|
|
|
|
other(1)
|
|
The agent does not recognize the status. You may need to
|
|
upgrade your software.
|
|
|
|
ok(2)
|
|
The fan module is operating normally. No user action is
|
|
required.
|
|
|
|
degraded(3)
|
|
The fan module is degraded. You need to check the fan module
|
|
for problems.
|
|
|
|
failed(4)
|
|
The fan module has failed. Replace the fan module."
|
|
::= { cpqSsFanModuleEntry 4 }
|
|
|
|
cpqSsFanModuleLocation OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
other(1),
|
|
fanBay(2),
|
|
composite(3),
|
|
fanBay2(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System Fan Module Location.
|
|
|
|
The following values are defined:
|
|
|
|
other(1)
|
|
The agent is unable to determine the location of this storage
|
|
system fan module.
|
|
|
|
fanBay(2)
|
|
This fan module is installed in the first fan bay.
|
|
|
|
composite(3)
|
|
The fan information is a composite of all fans in the storage
|
|
system.
|
|
|
|
fanBay2(4)
|
|
This fan module is installed in the second fan bay."
|
|
::= { cpqSsFanModuleEntry 5 }
|
|
|
|
cpqSsFanModuleSerialNumber OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..24))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System Fan Module Serial Number.
|
|
|
|
This is the fan module's serial number. This can be used
|
|
for identification purposes."
|
|
::= { cpqSsFanModuleEntry 6 }
|
|
|
|
cpqSsFanModuleBoardRevision OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..8))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System Fan Module Board Revision.
|
|
|
|
This is the fan module board revision."
|
|
::= { cpqSsFanModuleEntry 7 }
|
|
|
|
|
|
-- ****************************************************************************
|
|
-- Storage System Temperature Sensor Table
|
|
-- =======================================
|
|
--
|
|
-- The compaq enterprise (1.3.6.1.4.1.232)
|
|
-- cpqSsStorageSys Group (1.3.6.1.4.1.232.8)
|
|
-- cpqSsDrvBox Group (1.3.6.1.4.1.232.8.2)
|
|
-- cpqSsBoxExtended Group (1.3.6.1.4.1.232.8.2.2)
|
|
-- cpqSsTempSensorTable (1.3.6.1.4.1.232.8.2.2.5)
|
|
--
|
|
-- ****************************************************************************
|
|
|
|
cpqSsTempSensorTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CpqSsTempSensorEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System Temperature Sensor Table."
|
|
::= { cpqSsBoxExtended 5 }
|
|
|
|
cpqSsTempSensorEntry OBJECT-TYPE
|
|
SYNTAX CpqSsTempSensorEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System Temperature Sensor Entry."
|
|
INDEX { cpqSsTempSensorChassisIndex, cpqSsTempSensorIndex }
|
|
::= { cpqSsTempSensorTable 1 }
|
|
|
|
CpqSsTempSensorEntry ::= SEQUENCE
|
|
{
|
|
cpqSsTempSensorChassisIndex INTEGER,
|
|
cpqSsTempSensorIndex INTEGER,
|
|
cpqSsTempSensorStatus INTEGER,
|
|
cpqSsTempSensorCondition INTEGER,
|
|
cpqSsTempSensorLocation INTEGER,
|
|
cpqSsTempSensorCurrentValue INTEGER,
|
|
cpqSsTempSensorLimitValue INTEGER,
|
|
cpqSsTempSensorHysteresisValue INTEGER
|
|
}
|
|
|
|
cpqSsTempSensorChassisIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System Temperature Sensor Chassis Index.
|
|
|
|
The chassis index uniquely identifies a storage system chassis."
|
|
::= { cpqSsTempSensorEntry 1 }
|
|
|
|
cpqSsTempSensorIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System Temperature Sensor Index.
|
|
|
|
This index uniquely identifies a temperature sensor."
|
|
::= { cpqSsTempSensorEntry 2 }
|
|
|
|
cpqSsTempSensorStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
other(1),
|
|
ok(2),
|
|
degraded(3),
|
|
failed(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System Temperature Sensor Status.
|
|
|
|
The following values are defined:
|
|
|
|
other(1)
|
|
The agent is unable to determine if the storage system
|
|
temperature sensor status.
|
|
|
|
ok(2)
|
|
The temperature is OK.
|
|
|
|
degraded(3)
|
|
The temperature is degraded.
|
|
|
|
failed(4)
|
|
The temperature is failed."
|
|
::= { cpqSsTempSensorEntry 3 }
|
|
|
|
cpqSsTempSensorCondition OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
other(1),
|
|
ok(2),
|
|
degraded(3),
|
|
failed(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System Fan Module Condition.
|
|
|
|
This is the condition of the storage system temperature sensor.
|
|
The following values are defined:
|
|
|
|
other(1)
|
|
The agent does not recognize the status. You may need to
|
|
upgrade your software.
|
|
|
|
ok(2)
|
|
The temperature is within normal operating range. No user
|
|
action is required.
|
|
|
|
degraded(3)
|
|
The temperature is outside of normal operating range.
|
|
|
|
failed(4)
|
|
The temperature could permanently damage the system.
|
|
The storage system will automatically shutdown if this
|
|
condition is detected."
|
|
::= { cpqSsTempSensorEntry 4 }
|
|
|
|
cpqSsTempSensorLocation OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
other(1),
|
|
fanBay(2),
|
|
backplane(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System Fan Module Location.
|
|
|
|
The following values are defined:
|
|
|
|
other(1)
|
|
The agent is unable to determine the location of this storage
|
|
system temperature sensor.
|
|
|
|
fanBay(2)
|
|
This temperature sensor is located on the fan module in the
|
|
fan bay.
|
|
|
|
backplane(3)
|
|
This temperature is located on the SCSI drive backplane."
|
|
::= { cpqSsTempSensorEntry 5 }
|
|
|
|
cpqSsTempSensorCurrentValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System Temperature Sensor Current Value.
|
|
|
|
The current value of the temperature sensor in degrees Celsius."
|
|
::= { cpqSsTempSensorEntry 6 }
|
|
|
|
cpqSsTempSensorLimitValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System Temperature Sensor Limit Value.
|
|
|
|
The limit value of the temperature sensor in degrees Celsius."
|
|
::= { cpqSsTempSensorEntry 7 }
|
|
|
|
cpqSsTempSensorHysteresisValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System Temperature Sensor Hysteresis Value.
|
|
|
|
The hysteresis value of the temperature sensor in degrees Celsius."
|
|
::= { cpqSsTempSensorEntry 8 }
|
|
|
|
|
|
-- ****************************************************************************
|
|
-- Storage System SCSI Backplane Table
|
|
-- ===================================
|
|
--
|
|
-- The compaq enterprise (1.3.6.1.4.1.232)
|
|
-- cpqSsStorageSys Group (1.3.6.1.4.1.232.8)
|
|
-- cpqSsDrvBox Group (1.3.6.1.4.1.232.8.2)
|
|
-- cpqSsBoxExtended Group (1.3.6.1.4.1.232.8.2.2)
|
|
-- cpqSsBackplaneTable (1.3.6.1.4.1.232.8.2.2.6)
|
|
--
|
|
-- ****************************************************************************
|
|
|
|
cpqSsBackplaneTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CpqSsBackplaneEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System SCSI Backplane Table."
|
|
::= { cpqSsBoxExtended 6 }
|
|
|
|
cpqSsBackplaneEntry OBJECT-TYPE
|
|
SYNTAX CpqSsBackplaneEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System SCSI Backplane Entry."
|
|
INDEX { cpqSsBackplaneChassisIndex, cpqSsBackplaneIndex }
|
|
::= { cpqSsBackplaneTable 1 }
|
|
|
|
CpqSsBackplaneEntry ::= SEQUENCE
|
|
{
|
|
cpqSsBackplaneChassisIndex INTEGER,
|
|
cpqSsBackplaneIndex INTEGER,
|
|
cpqSsBackplaneFWRev DisplayString,
|
|
cpqSsBackplaneDriveBays INTEGER,
|
|
cpqSsBackplaneDuplexOption INTEGER,
|
|
cpqSsBackplaneCondition INTEGER,
|
|
cpqSsBackplaneVersion INTEGER,
|
|
cpqSsBackplaneVendor DisplayString,
|
|
cpqSsBackplaneModel DisplayString,
|
|
cpqSsBackplaneFanStatus INTEGER,
|
|
cpqSsBackplaneTempStatus INTEGER,
|
|
cpqSsBackplaneFtpsStatus INTEGER,
|
|
cpqSsBackplaneSerialNumber DisplayString,
|
|
cpqSsBackplanePlacement INTEGER,
|
|
cpqSsBackplaneBoardRevision INTEGER,
|
|
cpqSsBackplaneSpeed INTEGER,
|
|
cpqSsBackplaneConnectionType INTEGER,
|
|
cpqSsBackplaneConnector DisplayString,
|
|
cpqSsBackplaneOnConnector INTEGER,
|
|
cpqSsBackplaneLocationString DisplayString
|
|
}
|
|
|
|
cpqSsBackplaneChassisIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System Backplane Chassis Index.
|
|
|
|
The chassis index uniquely identifies a storage system chassis."
|
|
::= { cpqSsBackplaneEntry 1 }
|
|
|
|
cpqSsBackplaneIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System Backplane Index.
|
|
|
|
This index uniquely identifies a storage system backplane."
|
|
::= { cpqSsBackplaneEntry 2 }
|
|
|
|
cpqSsBackplaneFWRev OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..8))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System Backplane Firmware Revision.
|
|
|
|
This is the revision level of storage system backplane."
|
|
::= { cpqSsBackplaneEntry 3 }
|
|
|
|
cpqSsBackplaneDriveBays OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System Backplane Drive Bays.
|
|
|
|
This is the number of bays on this storage system backplane."
|
|
::= { cpqSsBackplaneEntry 4 }
|
|
|
|
cpqSsBackplaneDuplexOption OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
other(1),
|
|
notDuplexed(2),
|
|
duplexTop(3),
|
|
duplexBottom(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System Backplane Duplex Option.
|
|
|
|
The following values are defined:
|
|
|
|
other (1)
|
|
The agent is unable to determine if this storage
|
|
system is duplexed.
|
|
|
|
notDuplexed(2)
|
|
This storage system is not duplexed.
|
|
|
|
duplexTop(3)
|
|
This is the top portion of a duplexed storage system.
|
|
|
|
duplexBottom(4)
|
|
This is the bottom portion of a duplexed storage system."
|
|
::= { cpqSsBackplaneEntry 5 }
|
|
|
|
cpqSsBackplaneCondition OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
other(1),
|
|
ok(2),
|
|
degraded(3),
|
|
failed(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System Backplane Condition.
|
|
|
|
This is the overall condition of the backplane.
|
|
The following values are defined:
|
|
|
|
other(1)
|
|
The agent does not recognize the status. You may need to
|
|
upgrade your software.
|
|
|
|
ok(2)
|
|
The storage system is operating normally. No user
|
|
action is required.
|
|
|
|
degraded(3)
|
|
The storage system is degraded. You need to check the
|
|
temperature status or power supply status of this
|
|
storage system.
|
|
|
|
failed(4)
|
|
The storage system has failed."
|
|
::= { cpqSsBackplaneEntry 6 }
|
|
|
|
cpqSsBackplaneVersion OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System Backplane Version.
|
|
|
|
This is the version of the drive box back plane."
|
|
::= { cpqSsBackplaneEntry 7 }
|
|
|
|
cpqSsBackplaneVendor OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..9))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System Backplane Vendor
|
|
|
|
This is the storage box's vendor name.
|
|
This can be used for identification purposes."
|
|
::= { cpqSsBackplaneEntry 8 }
|
|
|
|
cpqSsBackplaneModel OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..17))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System Backplane Model.
|
|
|
|
This is a description of the storage system's model.
|
|
This can be used for identification purposes."
|
|
::= { cpqSsBackplaneEntry 9 }
|
|
|
|
cpqSsBackplaneFanStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
other(1),
|
|
notInstalled(2),
|
|
ok(3),
|
|
degraded(4),
|
|
failed(5),
|
|
notSupported(6),
|
|
degraded-Fan1Failed(7),
|
|
degraded-Fan2Failed(8)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System Backplane Fan Status.
|
|
|
|
This is the current status of the fans in the storage system.
|
|
This value will be one of the following:
|
|
|
|
other(1)
|
|
The agent is unable to determine if this storage system has
|
|
fan monitoring.
|
|
|
|
notInstalled(2)
|
|
This unit does not support fan monitoring.
|
|
|
|
ok(3)
|
|
All fans are working normally.
|
|
|
|
degraded(4)
|
|
At least one storage system fan has failed, but there is still
|
|
sufficient cooling capacity to allow the system to continue.
|
|
The fan should be replaced.
|
|
|
|
failed(5)
|
|
One or more storage system fans have failed. The fan(s) should
|
|
be replaced immediately to avoid hardware damage.
|
|
|
|
notSupported(6)
|
|
The storage system does not support reporting fan status
|
|
through this backplane. The fan status is reported through the
|
|
first backplane on this storage system.
|
|
|
|
degraded-Fan1Failed(7)
|
|
Fan 1 has failed, but there is still sufficient cooling
|
|
capacity to allow the system to continue. The fan should be
|
|
replaced.
|
|
|
|
degraded-Fan2Failed(8)
|
|
Fan 2 has failed, but there is still sufficient cooling
|
|
capacity to allow the system to continue. The fan should be
|
|
replaced."
|
|
|
|
::= { cpqSsBackplaneEntry 10 }
|
|
|
|
cpqSsBackplaneTempStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
other(1),
|
|
noTemp(2),
|
|
ok(3),
|
|
degraded(4),
|
|
failed(5),
|
|
notSupported(6)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System Backplane Fan Status.
|
|
|
|
This value will be one of the following:
|
|
|
|
other(1)
|
|
The agent is unable to determine if this storage system has
|
|
temperature monitoring.
|
|
|
|
noTemp(2)
|
|
This unit does not support temperature monitoring.
|
|
|
|
ok(3)
|
|
The temperature is within normal operating range.
|
|
|
|
degraded(4)
|
|
The temperature is outside of normal operating range.
|
|
|
|
failed(5)
|
|
The temperature could permanently damage the system.
|
|
|
|
notSupported(6)
|
|
The storage system does not support reporting temperature
|
|
status through this backplane. The temperature status is
|
|
reported through the first backplane on this storage system."
|
|
::= { cpqSsBackplaneEntry 11 }
|
|
|
|
cpqSsBackplaneFtpsStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
other(1),
|
|
noFltTolPower(2),
|
|
ok(3),
|
|
degraded(4),
|
|
failed(5),
|
|
notSupported(6),
|
|
noFltTolPower-Bay1Missing(7),
|
|
noFltTolPower-Bay2Missing(8)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System Backplane Fault Tolerant Power Supply Status.
|
|
|
|
This value specifies the overall status of the redundant power
|
|
supply in a drive box. This value will be one of the following:
|
|
|
|
other(1)
|
|
The agent is unable to determine if this storage system has
|
|
redundant power supplies.
|
|
|
|
noFltTolPower(2)
|
|
This unit does not have a redundant supply.
|
|
|
|
ok(3)
|
|
There are no detected power supply failures.
|
|
|
|
degraded(4)
|
|
One of the power supply units has failed.
|
|
|
|
failed(5)
|
|
All of the power supplies have failed. A status of failed can
|
|
not currently be determined.
|
|
|
|
notSupported(6)
|
|
The storage system does not support reporting fault tolerant
|
|
power supply status through this backplane. The fault tolerant
|
|
power supply status is reported through the first backplane on
|
|
this storage system.
|
|
|
|
noFltTolPower-Bay1Missing(7),
|
|
This unit does not have a redundant supply. The power supply
|
|
in bay 1 is missing.
|
|
|
|
noFltTolPower-Bay2Missing(8)
|
|
This unit does not have a redundant supply. The power supply
|
|
in bay 2 is missing."
|
|
::= { cpqSsBackplaneEntry 12 }
|
|
|
|
cpqSsBackplaneSerialNumber OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..24))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System Backplane Serial Number.
|
|
|
|
This is the storage system backplane serial number which is normally
|
|
displayed on the front bezel. This can be used for identification
|
|
purposes."
|
|
::= { cpqSsBackplaneEntry 13 }
|
|
|
|
cpqSsBackplanePlacement OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
other(1),
|
|
internal(2),
|
|
external(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System Backplane Placement.
|
|
|
|
The following values are defined:
|
|
|
|
other(1)
|
|
The agent is unable to determine if this storage system is
|
|
located internal or external to the system chassis.
|
|
|
|
internal(2)
|
|
The storage system is located in the system chassis.
|
|
|
|
external(3)
|
|
The storage system is located outside the system chassis
|
|
in an expansion box."
|
|
::= { cpqSsBackplaneEntry 14 }
|
|
|
|
cpqSsBackplaneBoardRevision OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System Backplane Board Revision.
|
|
|
|
This is the board revision of this storage system backplane."
|
|
::= { cpqSsBackplaneEntry 15 }
|
|
|
|
cpqSsBackplaneSpeed OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
other(1),
|
|
ultra3(2),
|
|
ultra320(3),
|
|
sata(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System Backplane Speed.
|
|
|
|
The following values are defined:
|
|
|
|
other(1)
|
|
The agent is unable to determine the backplane speed for this
|
|
storage system.
|
|
|
|
ultra3(2)
|
|
This storage system is capable of Ultra3 speeds.
|
|
|
|
ultra320(3)
|
|
This storage system is capable of Ultra320 speeds.
|
|
|
|
sata(4)
|
|
This storage system is capable of SATA speeds."
|
|
::= { cpqSsBackplaneEntry 16 }
|
|
|
|
|
|
cpqSsBackplaneConnectionType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
other(1),
|
|
scsiAttached(2),
|
|
sasAttached(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Backlane Box Connection Type.
|
|
|
|
The following values are defined:
|
|
|
|
other(1)
|
|
The agent is unable to determine the type of connection to
|
|
this backplane.
|
|
|
|
scsiAttached(2)
|
|
This backplane is attached to the host via SCSI.
|
|
|
|
sasAttached(3)
|
|
This backplane is attached to the host via SAS."
|
|
::= { cpqSsBackplaneEntry 17 }
|
|
|
|
cpqSsBackplaneConnector OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..4))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Backplane Connector.
|
|
|
|
This is the connector to which the backplane is attached.
|
|
If the backplane connector cannot be determined, the agent will
|
|
return a NULL string."
|
|
::= { cpqSsBackplaneEntry 18 }
|
|
|
|
cpqSsBackplaneOnConnector OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Backplane on Connector.
|
|
|
|
The backplane on connector indicates to which backplane instance
|
|
this table entry belongs. The instances start at one and
|
|
increment for each backplane attached to a connector."
|
|
::= { cpqSsBackplaneEntry 19 }
|
|
|
|
cpqSsBackplaneLocationString OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Backplane Location String.
|
|
|
|
This string describes the location of the backplane in relation
|
|
to the controller to which it is attached. If the location
|
|
string cannot be determined, the agent will return a NULL string."
|
|
::= { cpqSsBackplaneEntry 20 }
|
|
|
|
|
|
-- ****************************************************************************
|
|
-- Storage System Fibre Attachment Table
|
|
-- =====================================
|
|
--
|
|
-- The compaq enterprise (1.3.6.1.4.1.232)
|
|
-- cpqSsStorageSys Group (1.3.6.1.4.1.232.8)
|
|
-- cpqSsDrvBox Group (1.3.6.1.4.1.232.8.2)
|
|
-- cpqSsBoxExtended Group (1.3.6.1.4.1.232.8.2.2)
|
|
-- cpqSsFibreAttachmentTable (1.3.6.1.4.1.232.8.2.2.7)
|
|
--
|
|
-- The Storage System Fibre Attachment Group contains associations between
|
|
-- Fibre channel host controllers and the Fibre devices that are attached to
|
|
-- them. Since there can be multiple paths to some Fibre devices, there may
|
|
-- be multiple entries for a given device.
|
|
--
|
|
-- ****************************************************************************
|
|
|
|
cpqSsFibreAttachmentTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CpqSsFibreAttachmentEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System Fibre Attachment Table."
|
|
::= { cpqSsBoxExtended 7 }
|
|
|
|
cpqSsFibreAttachmentEntry OBJECT-TYPE
|
|
SYNTAX CpqSsFibreAttachmentEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System Fibre Attachment Entry."
|
|
INDEX { cpqSsFibreAttachmentIndex }
|
|
::= { cpqSsFibreAttachmentTable 1 }
|
|
|
|
CpqSsFibreAttachmentEntry ::= SEQUENCE
|
|
{
|
|
cpqSsFibreAttachmentIndex INTEGER,
|
|
cpqSsFibreAttachmentHostControllerIndex INTEGER,
|
|
cpqSsFibreAttachmentHostControllerPort INTEGER,
|
|
cpqSsFibreAttachmentDeviceType INTEGER,
|
|
cpqSsFibreAttachmentDeviceIndex INTEGER,
|
|
cpqSsFibreAttachmentDevicePort INTEGER
|
|
}
|
|
|
|
cpqSsFibreAttachmentIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System Fibre Attachment Index.
|
|
|
|
The index uniquely identifies a Fibre Attachment association entry."
|
|
::= { cpqSsFibreAttachmentEntry 1 }
|
|
|
|
cpqSsFibreAttachmentHostControllerIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System Fibre Attachment Host Controller Index.
|
|
|
|
The host controller index indicates which host controller is
|
|
associated with this entry. This is equal to cpqFcaHostCntlrIndex,
|
|
from the Fibre Channel Host Controller Table."
|
|
::= { cpqSsFibreAttachmentEntry 2 }
|
|
|
|
cpqSsFibreAttachmentHostControllerPort OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System Fibre Attachment Host Controller Port.
|
|
|
|
This is the Fibre port number of the host controller. For each host
|
|
controller, the port number starts at 1 and increments for each port.
|
|
This is currently set to 1."
|
|
::= { cpqSsFibreAttachmentEntry 3 }
|
|
|
|
cpqSsFibreAttachmentDeviceType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
other(1),
|
|
storageBox(2),
|
|
tapeController(3),
|
|
fibreChannelSwitch(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System Fibre Attachment Device Type.
|
|
|
|
This is the type of device associated with this entry.
|
|
The following values are defined:
|
|
|
|
other(1)
|
|
The agent is unable to determine if the type of this device.
|
|
|
|
storageBox(2)
|
|
The device is a Fibre attached storage system.
|
|
|
|
tapeController(3)
|
|
The device is a Fibre attached tape controller.
|
|
|
|
fibreChannelSwitch(4)
|
|
The device is a Fibre channel switch."
|
|
::= { cpqSsFibreAttachmentEntry 4 }
|
|
|
|
cpqSsFibreAttachmentDeviceIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System Fibre Attachment Device Index.
|
|
|
|
The is the index for the Fibre attached device. For a Fibre
|
|
attached storage system, this is equal to cpqSsChassisIndex from the
|
|
Storage System Chassis Table. For a Fibre attached tape controller,
|
|
this is equal to cpqFcTapeCntlrIndex from the Fibre Channel Tape
|
|
Controller Table. For a Fibre channel switch, this is equal to
|
|
cpqFcSwitchIndex from the Fibre Channel Switch Table."
|
|
::= { cpqSsFibreAttachmentEntry 5 }
|
|
|
|
cpqSsFibreAttachmentDevicePort OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System Fibre Attachment Device Port.
|
|
|
|
This is the Fibre port on a device. For a Fibre attached storage
|
|
system, this is equal to cpqFcaCntlrBoxIoSlot from the Fibre Channel
|
|
Array Controller Table. For a Fibre attached tape controller,
|
|
this is currently set to 1. For a Fibre channel switch, this is
|
|
currently set to 1."
|
|
::= { cpqSsFibreAttachmentEntry 6 }
|
|
|
|
|
|
-- ****************************************************************************
|
|
-- Storage System Scsi Attachment Table
|
|
-- ====================================
|
|
--
|
|
-- The compaq enterprise (1.3.6.1.4.1.232)
|
|
-- cpqSsStorageSys Group (1.3.6.1.4.1.232.8)
|
|
-- cpqSsDrvBox Group (1.3.6.1.4.1.232.8.2)
|
|
-- cpqSsBoxExtended Group (1.3.6.1.4.1.232.8.2.2)
|
|
-- cpqSsScsiAttachmentTable (1.3.6.1.4.1.232.8.2.2.8)
|
|
--
|
|
-- The Storage System Scsi Attachment Group contains associations between
|
|
-- internal array controllers and the external arrays that are attached to
|
|
-- them. Since there can be multiple paths to some external arrays, there
|
|
-- may be multiple entries for a given device.
|
|
--
|
|
-- ****************************************************************************
|
|
|
|
cpqSsScsiAttachmentTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CpqSsScsiAttachmentEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System SCSI Attachment Table."
|
|
::= { cpqSsBoxExtended 8 }
|
|
|
|
cpqSsScsiAttachmentEntry OBJECT-TYPE
|
|
SYNTAX CpqSsScsiAttachmentEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System SCSI Attachment Entry."
|
|
INDEX { cpqSsScsiAttachmentIndex }
|
|
::= { cpqSsScsiAttachmentTable 1 }
|
|
|
|
CpqSsScsiAttachmentEntry ::= SEQUENCE
|
|
{
|
|
cpqSsScsiAttachmentIndex INTEGER,
|
|
cpqSsScsiAttachmentControllerIndex INTEGER,
|
|
cpqSsScsiAttachmentControllerPort INTEGER,
|
|
cpqSsScsiAttachmentControllerTarget INTEGER,
|
|
cpqSsScsiAttachmentControllerLun INTEGER,
|
|
cpqSsScsiAttachmentChassisIndex INTEGER,
|
|
cpqSsScsiAttachmentChassisIoSlot INTEGER,
|
|
cpqSsScsiAttachmentPathStatus INTEGER,
|
|
cpqSsScsiAttachmentPathCondition INTEGER
|
|
}
|
|
|
|
cpqSsScsiAttachmentIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System SCSI Attachment Index.
|
|
|
|
The index uniquely identifies a SCSI Attachment association entry."
|
|
::= { cpqSsScsiAttachmentEntry 1 }
|
|
|
|
cpqSsScsiAttachmentControllerIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System SCSI Attachment Controller Index.
|
|
|
|
The controller index indicates which internal array controller is
|
|
associated with this entry. This is equal to cpqDaCntlrIndex,
|
|
from the Array Controller Table."
|
|
::= { cpqSsScsiAttachmentEntry 2 }
|
|
|
|
cpqSsScsiAttachmentControllerPort OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System SCSI Attachment Controller Port.
|
|
|
|
The controller port indicates which SCSI port of an internal
|
|
controller is associated with this entry."
|
|
::= { cpqSsScsiAttachmentEntry 3 }
|
|
|
|
cpqSsScsiAttachmentControllerTarget OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System SCSI Attachment Controller Target.
|
|
|
|
The controller target indicates which SCSI target is associated with
|
|
this entry."
|
|
::= { cpqSsScsiAttachmentEntry 4 }
|
|
|
|
cpqSsScsiAttachmentControllerLun OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System SCSI Attachment Controller Lun.
|
|
|
|
The controller Lun indicates which SCSI Lun is associated with this
|
|
entry."
|
|
::= { cpqSsScsiAttachmentEntry 5 }
|
|
|
|
cpqSsScsiAttachmentChassisIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System SCSI Attachment Chassis Index.
|
|
|
|
The is the index for the SCSI attached storage system. This is equal
|
|
to cpqSsChassisIndex from the Storage System Chassis Table."
|
|
::= { cpqSsScsiAttachmentEntry 6 }
|
|
|
|
cpqSsScsiAttachmentChassisIoSlot OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System SCSI Attachment Chassis I/O Slot.
|
|
|
|
This is the I/O slot in the SCSI attached storage system. This is
|
|
equal to cpqFcaCntlrBoxIoSlot from the Fibre Channel Array Controller
|
|
Table."
|
|
::= { cpqSsScsiAttachmentEntry 7 }
|
|
|
|
cpqSsScsiAttachmentPathStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
other(1),
|
|
ok(2),
|
|
offline(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System SCSI Attachment Path Status.
|
|
|
|
This is the status of this path to the chassis. The following
|
|
values are defined:
|
|
|
|
other(1)
|
|
The agent does not recognize the status. You may need to
|
|
upgrade your software.
|
|
|
|
ok(2)
|
|
The path is operating normally.
|
|
|
|
offline(3)
|
|
The path is offline."
|
|
::= { cpqSsScsiAttachmentEntry 8 }
|
|
|
|
cpqSsScsiAttachmentPathCondition OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
other(1),
|
|
ok(2),
|
|
degraded(3),
|
|
failed(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Storage System SCSI Attachment Path Condition.
|
|
|
|
This is the condition of this path to the chassis."
|
|
::= { cpqSsScsiAttachmentEntry 9 }
|
|
|
|
-- ****************************************************************************
|
|
-- Storage System Drive Box Access Path Group
|
|
-- ==========================================
|
|
--
|
|
-- The compaq enterprise (1.3.6.1.4.1.232)
|
|
-- cpqSsStorageSys Group (1.3.6.1.4.1.232.8)
|
|
-- cpqSsDrvBox Group (1.3.6.1.4.1.232.8.2)
|
|
-- cpqSsDrvBoxPathTable (1.3.6.1.4.1.232.8.2.3)
|
|
--
|
|
-- ****************************************************************************
|
|
|
|
cpqSsDrvBoxPathTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CpqSsDrvBoxPathEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Drive Box Access Path Table."
|
|
::= { cpqSsDrvBox 3 }
|
|
|
|
cpqSsDrvBoxPathEntry OBJECT-TYPE
|
|
SYNTAX CpqSsDrvBoxPathEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Drive Box Access Path Entry."
|
|
INDEX { cpqSsDrvBoxPathCntlrIndex, cpqSsDrvBoxPathBoxIndex,
|
|
cpqSsDrvBoxPathIndex }
|
|
::= { cpqSsDrvBoxPathTable 1 }
|
|
|
|
CpqSsDrvBoxPathEntry ::= SEQUENCE
|
|
{
|
|
cpqSsDrvBoxPathCntlrIndex INTEGER,
|
|
cpqSsDrvBoxPathBoxIndex INTEGER,
|
|
cpqSsDrvBoxPathIndex INTEGER,
|
|
cpqSsDrvBoxPathStatus INTEGER,
|
|
cpqSsDrvBoxPathCurrentRole INTEGER,
|
|
cpqSsDrvBoxPathHostConnector DisplayString,
|
|
cpqSsDrvBoxPathBoxOnConnector INTEGER,
|
|
cpqSsDrvBoxPathLocationString DisplayString
|
|
}
|
|
|
|
cpqSsDrvBoxPathCntlrIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Drive Box Access Path Controller Index.
|
|
|
|
The controller index indicates to which adapter card instance
|
|
this table entry belongs."
|
|
::= { cpqSsDrvBoxPathEntry 1 }
|
|
|
|
cpqSsDrvBoxPathBoxIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Drive Box Access Path Box Index.
|
|
|
|
The box index indicates to which box instance on an adapter card
|
|
this table entry belongs. The value of this index is the same as
|
|
cpqSsDrvBoxBusIndex used under the drive box table."
|
|
::= { cpqSsDrvBoxPathEntry 2 }
|
|
|
|
cpqSsDrvBoxPathIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Drive Box Access Path Index.
|
|
|
|
This path index keeps track of multiple instances of access
|
|
paths from a controller to a storage box. This number, along with
|
|
the cpqSsDrvBoxPathCntlrIndex and cpqSsDrvBoxPathDrvIndex uniquely
|
|
identify a specific storage box access path"
|
|
::= { cpqSsDrvBoxPathEntry 3 }
|
|
|
|
cpqSsDrvBoxPathStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
other(1),
|
|
ok(2),
|
|
linkDown(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Drive Box Access Path Status.
|
|
|
|
This shows the status of the drive box access path. The
|
|
following values are valid:
|
|
|
|
Other (1)
|
|
Indicates that the instrument agent can not determine the
|
|
status of this access path.
|
|
|
|
OK (2)
|
|
Indicates the access path is functioning properly.
|
|
|
|
Link Down (3)
|
|
Indicates that the controller can no longer access the drive box
|
|
through this path."
|
|
::= { cpqSsDrvBoxPathEntry 4 }
|
|
|
|
cpqSsDrvBoxPathCurrentRole OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
other(1),
|
|
active(2),
|
|
alternate(3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Drive Box Access Path Current Role.
|
|
|
|
This shows the current role of drive box acess path. The
|
|
following values are valid:
|
|
|
|
Other (1)
|
|
Indicates that the instrument agent does not recognize the
|
|
role of this access path.
|
|
|
|
Active (2)
|
|
Indicates that this path is currently the default active
|
|
I/O path to access the drive box from the controller.
|
|
|
|
Alternate (3)
|
|
Indicates that this path is currently the alternate I/O
|
|
path to access the physical drive from the controller."
|
|
::= { cpqSsDrvBoxPathEntry 5 }
|
|
|
|
cpqSsDrvBoxPathHostConnector OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..4))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Drive Box Access Path Host Connector.
|
|
|
|
This is the host connector to which the access path is ultimately
|
|
attached. If the host connector cannot be determined, the agent
|
|
will return a NULL string."
|
|
::= { cpqSsDrvBoxPathEntry 6 }
|
|
|
|
cpqSsDrvBoxPathBoxOnConnector OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Drive Box Access Path Box on Connector.
|
|
|
|
The box on connector indicates to which box instance this
|
|
access path belongs."
|
|
::= { cpqSsDrvBoxPathEntry 7 }
|
|
|
|
cpqSsDrvBoxPathLocationString OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Drive Box Access Path Location String.
|
|
|
|
This string describes drive box access path in relation to the
|
|
controller to which it is attached. If the location string
|
|
cannot be determined, the agent will return a NULL string."
|
|
::= { cpqSsDrvBoxPathEntry 8 }
|
|
|
|
|
|
-- ****************************************************************************
|
|
-- Storage System Trap Group
|
|
-- =========================
|
|
--
|
|
-- The compaq enterprise (1.3.6.1.4.1.232)
|
|
-- cpqSsStorageSys Group (1.3.6.1.4.1.232.8)
|
|
-- cpqSsTrap Group (1.3.6.1.4.1.232.8.3) (deprecated)
|
|
--
|
|
--
|
|
-- The trap group maintains information about the number of traps issued
|
|
-- from the storageSys enterprise. The trap group also maintains a table of
|
|
-- the last several traps issued. This table is intended to give a
|
|
-- management application some recent status information immediately upon
|
|
-- accessing the agent.
|
|
--
|
|
-- Implementation of the Trap group is optional for agents.
|
|
-- The trap group has been deprecated for Insight v2.00 Agents.
|
|
--
|
|
-- ****************************************************************************
|
|
|
|
cpqSsTrapPkts OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The total number of trap packets issued by the enterprise since
|
|
the instrument agent was loaded."
|
|
::= { cpqSsTrap 1 }
|
|
|
|
cpqSsTrapLogMaxSize OBJECT-TYPE
|
|
SYNTAX INTEGER (0..2147483647)
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The maximum number of entries that will currently be kept in
|
|
the trap log. If the maximum size has been reached and a new
|
|
trap occurs the oldest trap will be removed."
|
|
::= { cpqSsTrap 2 }
|
|
|
|
-- ****************************************************************************
|
|
-- Storage System Trap Log Table
|
|
-- =============================
|
|
--
|
|
-- The compaq enterprise (1.3.6.1.4.1.232)
|
|
-- cpqSsStorageSys Group (1.3.6.1.4.1.232.8)
|
|
-- cpqSsTrap Group (1.3.6.1.4.1.232.8.3) (deprecated)
|
|
-- cpqSsTrapLogTable (1.3.6.1.4.1.232.8.3.3) (deprecated)
|
|
--
|
|
-- ****************************************************************************
|
|
|
|
cpqSsTrapLogTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CpqSsTrapLogEntry
|
|
ACCESS not-accessible
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"An ordered list of trap log entries (conceptually a queue).
|
|
The trap log entries will be kept in the order in which they
|
|
were generated with the most recent trap at index 1 and the
|
|
oldest trap entry at index trapLogMaxSize. If the maximum
|
|
number size has been reached and a new trap occurs the oldest
|
|
trap will be removed when the new trap is added so the
|
|
trapMaxLogSize is not exceeded."
|
|
::= { cpqSsTrap 3 }
|
|
|
|
cpqSsTrapLogEntry OBJECT-TYPE
|
|
SYNTAX CpqSsTrapLogEntry
|
|
ACCESS not-accessible
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"A description of a trap event."
|
|
INDEX { cpqSsTrapLogIndex }
|
|
::= { cpqSsTrapLogTable 1 }
|
|
|
|
CpqSsTrapLogEntry ::= SEQUENCE
|
|
{
|
|
cpqSsTrapLogIndex INTEGER,
|
|
cpqSsTrapType INTEGER,
|
|
cpqSsTrapTime OCTET STRING
|
|
}
|
|
|
|
cpqSsTrapLogIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (0..2147483647)
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The value of this object uniquely identifies this trapLogEntry
|
|
at this time. The most recent trap will have an index of 1 and
|
|
the oldest trap will have an index of trapLogMaxSize. Because of
|
|
the queue-like nature of the trapLog this particular trap event's
|
|
index will change as new traps are issued."
|
|
::= { cpqSsTrapLogEntry 1 }
|
|
|
|
cpqSsTrapType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
cpqSsFanStatusChange(1),
|
|
cpqSs2FanStatusChange(8001),
|
|
cpqSsTempFailed(8002),
|
|
cpqSsTempDegraded(8003),
|
|
cpqSsTempOk(8004),
|
|
cpqSsSidePanelInPlace(8005),
|
|
cpqSsSidePanelRemoved(8006)
|
|
}
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The type of the trap event that this entry describes. This
|
|
number refers to an entry in a list of traps enumerating the
|
|
possible traps the agent may issue."
|
|
::= { cpqSsTrapLogEntry 2 }
|
|
|
|
cpqSsTrapTime OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (6))
|
|
ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The time of the trap event that this entry describes. The time
|
|
is given in year (first octet), month, day of month, hour,
|
|
minute, second (last octet) order. Each octet gives the value in
|
|
BCD."
|
|
::= { cpqSsTrapLogEntry 3 }
|
|
|
|
|
|
-- ****************************************************************************
|
|
-- RAID Storage System Group
|
|
-- ==============================
|
|
--
|
|
-- The compaq enterprise (1.3.6.1.4.1.232)
|
|
-- cpqSsStorageSys Group (1.3.6.1.4.1.232.8)
|
|
-- cpqSsRaidSystem Group (1.3.6.1.4.1.232.8.4)
|
|
-- cpqSsRaidSystemTable (1.3.6.1.4.1.232.8.4.1)
|
|
--
|
|
-- Implementation of the RAID Storage System group is mandatory.
|
|
--
|
|
-- ****************************************************************************
|
|
|
|
cpqSsRaidSystemTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CpqSsRaidSystemEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"RAID Storage System Table."
|
|
::= { cpqSsRaidSystem 1 }
|
|
|
|
cpqSsRaidSystemEntry OBJECT-TYPE
|
|
SYNTAX CpqSsRaidSystemEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"RAID Storage System Entry."
|
|
INDEX { cpqSsRaidSystemIndex }
|
|
::= { cpqSsRaidSystemTable 1 }
|
|
|
|
CpqSsRaidSystemEntry ::= SEQUENCE
|
|
{
|
|
cpqSsRaidSystemIndex INTEGER,
|
|
cpqSsRaidSystemName DisplayString,
|
|
cpqSsRaidSystemStatus INTEGER,
|
|
cpqSsRaidSystemCondition INTEGER,
|
|
cpqSsRaidSystemCntlr1SerialNumber DisplayString,
|
|
cpqSsRaidSystemCntlr2SerialNumber DisplayString
|
|
}
|
|
|
|
cpqSsRaidSystemIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"RAID Storage System Index.
|
|
|
|
The RAID Storage System index indicates to which storage system instance
|
|
this table entry belongs."
|
|
|
|
::= { cpqSsRaidSystemEntry 1 }
|
|
|
|
cpqSsRaidSystemName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"RAID Storage System Name.
|
|
|
|
This is a description of the RAID Storage System's name.
|
|
This can be used for identification purposes."
|
|
|
|
::= { cpqSsRaidSystemEntry 2 }
|
|
|
|
cpqSsRaidSystemStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
other(1),
|
|
agentNotRunning(2),
|
|
good(3),
|
|
warning(4),
|
|
communicationLoss(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"RAID Storage System Status.
|
|
|
|
This is the current status of the RAID Storage System.
|
|
This value will be one of the following:
|
|
|
|
other(1)
|
|
Indicates that the agent does not recognize the state of the
|
|
RAID Storage System. You may need to upgrade the agent.
|
|
|
|
agentNotRunning(2)
|
|
Indicates that the Storage Work agent is not running. You need
|
|
to restart the Storage Work agent.
|
|
|
|
good(3)
|
|
Indicates that the system is operating properly.
|
|
|
|
warning(4)
|
|
At least one component of the system failed.
|
|
|
|
communicationLoss(5)
|
|
The RAID Storage System has a cable or communication problem.
|
|
Please check all cable connects to the host server."
|
|
|
|
|
|
::= { cpqSsRaidSystemEntry 3 }
|
|
|
|
cpqSsRaidSystemCondition OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
other(1),
|
|
ok(2),
|
|
degraded(3),
|
|
failed(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"RAID Storage System Condition.
|
|
|
|
This is the overall condition of the storage system.
|
|
The following values are defined:
|
|
|
|
other(1)
|
|
The agent does not recognize the status. You may need to
|
|
upgrade your software.
|
|
|
|
ok(2)
|
|
The storage system is operating normally. No user
|
|
action is required.
|
|
|
|
degraded(3)
|
|
The storage system is degraded. At least one component
|
|
of the storage system failed.
|
|
|
|
failed(4)
|
|
The storage system has failed."
|
|
|
|
::= { cpqSsRaidSystemEntry 4 }
|
|
|
|
cpqSsRaidSystemCntlr1SerialNumber OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..24))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"RAID Storage System Controller 1 Serial Number.
|
|
|
|
This is the controller number 1's serial number which is normally
|
|
display on the front panel. This can be used for
|
|
identification purposes."
|
|
|
|
::= { cpqSsRaidSystemEntry 5 }
|
|
|
|
cpqSsRaidSystemCntlr2SerialNumber OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..24))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"RAID Storage System Controller 2 Serial Number.
|
|
|
|
This is the controller number 2's serial number which is normally
|
|
display on the front panel. This can be used for
|
|
identification purposes."
|
|
|
|
::= { cpqSsRaidSystemEntry 6 }
|
|
|
|
|
|
-- ****************************************************************************
|
|
-- Storage System Trap Definitions
|
|
-- ===============================
|
|
--
|
|
-- The compaq enterprise (1.3.6.1.4.1.232)
|
|
--
|
|
-- The SNMP trap messages must not be bigger than 484 octets (bytes).
|
|
--
|
|
-- Trap support in an SNMP agent implementation is optional. An SNMP
|
|
-- agent implementation may support all, some, or none of the traps.
|
|
-- If traps are supported, The user should be provided with the option of
|
|
-- disabling traps.
|
|
--
|
|
-- **************************************************************************
|
|
|
|
cpqSsFanStatusChange TRAP-TYPE
|
|
ENTERPRISE cpqSsStorageSys
|
|
VARIABLES { cpqSsBoxFanStatus }
|
|
DESCRIPTION
|
|
"Storage System fan status change.
|
|
|
|
The agent has detected a change in the Fan Status of a storage
|
|
system. The variable cpqSsBoxFanStatus indicates the current
|
|
fan status."
|
|
|
|
--#TYPE "Fan Status Change (1)"
|
|
--#SUMMARY "Storage System fan status changed to %d."
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY CRITICAL
|
|
--#TIMEINDEX 99
|
|
|
|
::= 1
|
|
|
|
cpqSs2FanStatusChange TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { cpqSsBoxFanStatus }
|
|
DESCRIPTION
|
|
"Storage System fan status change.
|
|
|
|
The agent has detected a change in the Fan Status of a storage
|
|
system. The variable cpqSsBoxFanStatus indicates the current
|
|
fan status."
|
|
|
|
--#TYPE "Fan Status Change (8001)"
|
|
--#SUMMARY "Storage System fan status changed to %d."
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY CRITICAL
|
|
--#TIMEINDEX 99
|
|
|
|
::= 8001
|
|
|
|
cpqSsTempFailed TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { cpqSsBoxTempStatus }
|
|
DESCRIPTION
|
|
"Storage System temperature failure.
|
|
|
|
The agent has detected that a temperature status has been set
|
|
to failed. The storage system will be shutdown."
|
|
|
|
--#TYPE "Storage System Temperature Failure (8002)"
|
|
--#SUMMARY "Storage System will be shutdown."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY CRITICAL
|
|
--#TIMEINDEX 99
|
|
--#STATE NONOPERATIONAL
|
|
|
|
::= 8002
|
|
|
|
cpqSsTempDegraded TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { cpqSsBoxTempStatus }
|
|
DESCRIPTION
|
|
"Storage System temperature degraded.
|
|
|
|
The agent has detected a temperature status that has been set to
|
|
degraded. The storage system's temperature is outside of the
|
|
normal operating range."
|
|
|
|
--#TYPE "Storage System Temp Degraded (8003)"
|
|
--#SUMMARY "Temp is outside of normal range."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 99
|
|
--#STATE DEGRADED
|
|
|
|
::= 8003
|
|
|
|
cpqSsTempOk TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { cpqSsBoxTempStatus }
|
|
DESCRIPTION
|
|
"Storage System temperature ok.
|
|
|
|
The temperature status has been set to OK. The storage
|
|
system's temperature has returned to normal operating range.
|
|
It may be reactivated by the administrator."
|
|
|
|
--#TYPE "Storage System Temp OK (8004)"
|
|
--#SUMMARY "Storage System temperature ok."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
|
|
::= 8004
|
|
|
|
cpqSsSidePanelInPlace TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { cpqSsBoxSidePanelStatus }
|
|
DESCRIPTION
|
|
"Storage System side panel is in place.
|
|
|
|
The side panel status has been set to in place. The storage
|
|
system's side panel has returned to a properly installed state."
|
|
|
|
--#TYPE "Storage System side panel is in place (8005)"
|
|
--#SUMMARY "Side panel is re-installed on unit."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
|
|
::= 8005
|
|
|
|
|
|
cpqSsSidePanelRemoved TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { cpqSsBoxSidePanelStatus }
|
|
DESCRIPTION
|
|
"Storage System side panel is removed.
|
|
|
|
The side panel status has been set to removed. The storage
|
|
system's side panel is not in a properly installed state. This
|
|
situation may result in improper cooling of the drives in the
|
|
storage system due to air flow changes caused by the missing
|
|
side panel."
|
|
|
|
--#TYPE "Storage System side panel is removed (8006)"
|
|
--#SUMMARY "Side panel is removed from unit."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 99
|
|
--#STATE DEGRADED
|
|
|
|
::= 8006
|
|
|
|
cpqSsPwrSupplyDegraded TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
DESCRIPTION
|
|
"A storage system power supply status has been set to degraded."
|
|
|
|
--#TYPE "Power Supply Degraded (8007)"
|
|
--#SUMMARY "A storage system power supply unit has become degraded"
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY CRITICAL
|
|
--#TIMEINDEX 99
|
|
--#STATE DEGRADED
|
|
|
|
::= 8007
|
|
|
|
|
|
cpqSs3FanStatusChange TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqSsBoxFanStatus }
|
|
DESCRIPTION
|
|
"Storage System fan status change.
|
|
|
|
The agent has detected a change in the Fan Status of a storage
|
|
system. The variable cpqSsBoxFanStatus indicates the current
|
|
fan status.
|
|
|
|
User Action: If the fan status is degraded or failed, replace
|
|
any failed fans."
|
|
|
|
--#TYPE "Fan Status Change (8008)"
|
|
--#SUMMARY "Storage System fan status changed to %d."
|
|
--#ARGUMENTS {2}
|
|
--#SEVERITY CRITICAL
|
|
--#TIMEINDEX 99
|
|
|
|
::= 8008
|
|
|
|
cpqSs3TempFailed TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqSsBoxTempStatus }
|
|
DESCRIPTION
|
|
"Storage System temperature failure.
|
|
|
|
The agent has detected that a temperature status has been set to
|
|
failed. The storage system will be shutdown.
|
|
|
|
User Action: Shutdown the storage system as soon as possible.
|
|
Insure that the storage system environment is being cooled
|
|
properly and that no components are overheated."
|
|
|
|
--#TYPE "Storage System Temperature Failure (8009)"
|
|
--#SUMMARY "Storage System will be shutdown."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY CRITICAL
|
|
--#TIMEINDEX 99
|
|
--#STATE NONOPERATIONAL
|
|
|
|
::= 8009
|
|
|
|
cpqSs3TempDegraded TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqSsBoxTempStatus }
|
|
DESCRIPTION
|
|
"Storage System temperature degraded.
|
|
|
|
The agent has detected a temperature status that has been set to
|
|
degraded. The storage system's temperature is outside of the
|
|
normal operating range.
|
|
|
|
User Action: Shutdown the storage system as soon as possible.
|
|
Insure that the storage system environment is being cooled
|
|
properly and that no components are overheated."
|
|
|
|
--#TYPE "Storage System Temp Degraded (8010)"
|
|
--#SUMMARY "Temp is outside of normal range."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 99
|
|
--#STATE DEGRADED
|
|
|
|
::= 8010
|
|
|
|
cpqSs3TempOk TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqSsBoxTempStatus }
|
|
DESCRIPTION
|
|
"Storage System temperature ok.
|
|
|
|
The temperature status has been set to OK. The storage
|
|
system's temperature has returned to normal operating range.
|
|
It may be reactivated by the administrator.
|
|
|
|
User Action: None."
|
|
|
|
--#TYPE "Storage System Temp OK (8011)"
|
|
--#SUMMARY "Storage System temperature ok."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
|
|
::= 8011
|
|
|
|
cpqSs3SidePanelInPlace TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqSsBoxSidePanelStatus }
|
|
DESCRIPTION
|
|
"Storage System side panel is in place.
|
|
|
|
The side panel status has been set to in place. The storage
|
|
system's side panel has returned to a properly installed state.
|
|
|
|
User Action: None."
|
|
|
|
--#TYPE "Storage System side panel is in place (8012)"
|
|
--#SUMMARY "Side panel is re-installed on unit."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
|
|
::= 8012
|
|
|
|
|
|
cpqSs3SidePanelRemoved TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqSsBoxSidePanelStatus }
|
|
DESCRIPTION
|
|
"Storage System side panel is removed.
|
|
|
|
The side panel status has been set to removed. The storage
|
|
system's side panel is not in a properly installed state. This
|
|
situation may result in improper cooling of the drives in the
|
|
storage system due to air flow changes caused by the missing
|
|
side panel.
|
|
|
|
User Action: Replace the storage system side panel."
|
|
|
|
--#TYPE "Storage System side panel is removed (8013)"
|
|
--#SUMMARY "Side panel is removed from unit."
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 99
|
|
--#STATE DEGRADED
|
|
|
|
::= 8013
|
|
|
|
cpqSs3PwrSupplyDegraded TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags }
|
|
DESCRIPTION
|
|
"A storage system power supply status has been set to degraded."
|
|
|
|
--#TYPE "Power Supply Degraded (8014)"
|
|
--#SUMMARY "A storage system power supply unit has become degraded"
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY CRITICAL
|
|
--#TIMEINDEX 99
|
|
--#STATE DEGRADED
|
|
::= 8014
|
|
|
|
cpqSs4PwrSupplyDegraded TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqSsBoxFltTolPwrSupplyStatus }
|
|
DESCRIPTION
|
|
"A storage system power supply status has been set to degraded.
|
|
|
|
User Action: Take action to restore power or replace any failed
|
|
storage system power supply."
|
|
|
|
--#TYPE "Power Supply Degraded (8015)"
|
|
--#SUMMARY "A storage system power supply unit has become degraded"
|
|
--#ARGUMENTS {}
|
|
--#SEVERITY CRITICAL
|
|
--#TIMEINDEX 99
|
|
--#STATE DEGRADED
|
|
|
|
::= 8015
|
|
|
|
|
|
cpqSsExFanStatusChange TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqSsChassisName,
|
|
cpqSsChassisTime, cpqSsFanModuleLocation,
|
|
cpqSsFanModuleStatus }
|
|
DESCRIPTION
|
|
"Storage system fan status change.
|
|
|
|
The agent has detected a change in the Fan Module Status of a
|
|
storage system. The variable cpqSsFanModuleStatus indicates the
|
|
current fan status.
|
|
|
|
User Action: If the fan status is degraded or failed, replace
|
|
any failed fans."
|
|
|
|
--#TYPE "Fan Status Change (8016)"
|
|
--#SUMMARY "Storage system fan status changed to %d."
|
|
--#ARGUMENTS {5}
|
|
--#SEVERITY CRITICAL
|
|
--#TIMEINDEX 99
|
|
|
|
::= 8016
|
|
|
|
cpqSsExPowerSupplyStatusChange TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqSsChassisName,
|
|
cpqSsChassisTime, cpqSsPowerSupplyBay,
|
|
cpqSsPowerSupplyStatus }
|
|
DESCRIPTION
|
|
"Storage system power supply status change.
|
|
|
|
The agent has detected a change in the power supply status of a
|
|
storage system. The variable cpqSsPowerSupplyStatus indicates
|
|
the current status.
|
|
|
|
User Action: If the power supply status is failed, take action to
|
|
restore power or replace the failed power supply."
|
|
|
|
--#TYPE "Power Supply Status Change (8017)"
|
|
--#SUMMARY "Storage system power supply status changed to %d."
|
|
--#ARGUMENTS {5}
|
|
--#SEVERITY CRITICAL
|
|
--#TIMEINDEX 99
|
|
|
|
::= 8017
|
|
|
|
cpqSsExPowerSupplyUpsStatusChange TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqSsChassisName,
|
|
cpqSsChassisTime, cpqSsPowerSupplyBay,
|
|
cpqSsPowerSupplyUpsStatus }
|
|
DESCRIPTION
|
|
"Storage system power supply UPS status change.
|
|
|
|
The agent has detected a change status of a UPS attached to a
|
|
storage system power supply. The variable
|
|
cpqSsPowerSupplyUpsStatus indicates the current status.
|
|
|
|
User Action: If the UPS status is powerFailed(4) or batteryLow(5),
|
|
take action to restore power to the UPS."
|
|
|
|
--#TYPE "Power Supply UPS Status Change (8018)"
|
|
--#SUMMARY "Storage system power supply UPS status changed to %d."
|
|
--#ARGUMENTS {5}
|
|
--#SEVERITY CRITICAL
|
|
--#TIMEINDEX 99
|
|
|
|
::= 8018
|
|
|
|
cpqSsExTempSensorStatusChange TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqSsChassisName,
|
|
cpqSsChassisTime, cpqSsTempSensorLocation,
|
|
cpqSsTempSensorStatus, cpqSsTempSensorCurrentValue }
|
|
DESCRIPTION
|
|
"Storage system temperature sensor status change.
|
|
|
|
The agent has detected a change in the status of a storage
|
|
system temperature sensor. The variable cpqSsTempSensorStatus
|
|
indicates the current status.
|
|
|
|
User Action: If the temperature status is degraded or failed,
|
|
shutdown the storage system as soon as possible. Insure that
|
|
the storage system environment is being cooled properly and that
|
|
no components are overheated."
|
|
|
|
--#TYPE "Temperature Sensor Status Change (8019)"
|
|
--#SUMMARY "Storage system temperature sensor status changed to %d."
|
|
--#ARGUMENTS {5}
|
|
--#SEVERITY CRITICAL
|
|
--#TIMEINDEX 99
|
|
--#VARBINDSEVERITY 2
|
|
|
|
::= 8019
|
|
|
|
cpqSsEx2FanStatusChange TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqSsChassisName,
|
|
cpqSsChassisTime, cpqSsFanModuleLocation,
|
|
cpqSsFanModuleStatus, cpqSsFanModuleSerialNumber,
|
|
cpqSsFanModuleBoardRevision }
|
|
DESCRIPTION
|
|
"Storage system fan status change.
|
|
|
|
The agent has detected a change in the fan module status of a
|
|
storage system. The variable cpqSsFanModuleStatus indicates the
|
|
current fan status.
|
|
|
|
User Action: If the fan status is degraded or failed, replace
|
|
any failed fans."
|
|
|
|
--#TYPE "Fan Status Change (8020)"
|
|
--#SUMMARY "Storage system fan status changed to %d."
|
|
--#ARGUMENTS {5}
|
|
--#SEVERITY CRITICAL
|
|
--#TIMEINDEX 99
|
|
--#VARBINDSEVERITY 2
|
|
|
|
::= 8020
|
|
|
|
cpqSsEx2PowerSupplyStatusChange TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqSsChassisName,
|
|
cpqSsChassisTime, cpqSsPowerSupplyBay,
|
|
cpqSsPowerSupplyStatus, cpqSsPowerSupplySerialNumber,
|
|
cpqSsPowerSupplyBoardRevision,
|
|
cpqSsPowerSupplyFirmwareRevision }
|
|
DESCRIPTION
|
|
"Storage system power supply status change.
|
|
|
|
The agent has detected a change in the power supply status of a
|
|
storage system. The variable cpqSsPowerSupplyStatus indicates
|
|
the current status.
|
|
|
|
User Action: If the power supply status is failed, take action to
|
|
restore power or replace the failed power supply."
|
|
|
|
--#TYPE "Power Supply Status Change (8021)"
|
|
--#SUMMARY "Storage system power supply status changed to %d."
|
|
--#ARGUMENTS {5}
|
|
--#SEVERITY CRITICAL
|
|
--#TIMEINDEX 99
|
|
--#VARBINDSEVERITY 2
|
|
|
|
::= 8021
|
|
|
|
cpqSsExBackplaneFanStatusChange TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqSsChassisName,
|
|
cpqSsChassisTime, cpqSsBackplaneIndex,
|
|
cpqSsBackplaneVendor, cpqSsBackplaneModel,
|
|
cpqSsBackplaneSerialNumber, cpqSsBackplaneFanStatus }
|
|
DESCRIPTION
|
|
"Storage system fan status change.
|
|
|
|
The agent has detected a change in the fan status of a storage
|
|
system. The variable cpqSsBackplaneFanStatus indicates the
|
|
current fan status.
|
|
|
|
User Action: If the fan status is degraded or failed, replace
|
|
any failed fans."
|
|
|
|
--#TYPE "Storage System Fan Status Change (8022)"
|
|
--#SUMMARY "Storage system fan status changed to %d."
|
|
--#ARGUMENTS {8}
|
|
--#SEVERITY CRITICAL
|
|
--#TIMEINDEX 99
|
|
--#VARBINDSEVERITY 2
|
|
|
|
::= 8022
|
|
|
|
cpqSsExBackplaneTempStatusChange TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqSsChassisName,
|
|
cpqSsChassisTime, cpqSsBackplaneIndex,
|
|
cpqSsBackplaneVendor, cpqSsBackplaneModel,
|
|
cpqSsBackplaneSerialNumber, cpqSsBackplaneTempStatus }
|
|
DESCRIPTION
|
|
"Storage system temperature status change.
|
|
|
|
The agent has detected a change in the status of the temperature
|
|
in a storage system. The variable cpqSsBackplaneTempStatus
|
|
indicates the current status.
|
|
|
|
User Action: If the temperature status is degraded or failed,
|
|
shutdown the storage system as soon as possible. Insure that
|
|
the storage system environment is being cooled properly and that
|
|
no components are overheated."
|
|
|
|
--#TYPE "Storage System Temperature Status Change (8023)"
|
|
--#SUMMARY "Storage system temperature status changed to %d."
|
|
--#ARGUMENTS {8}
|
|
--#SEVERITY CRITICAL
|
|
--#TIMEINDEX 99
|
|
--#VARBINDSEVERITY 2
|
|
|
|
::= 8023
|
|
|
|
cpqSsExBackplanePowerSupplyStatusChange TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqSsChassisName,
|
|
cpqSsChassisTime, cpqSsBackplaneIndex,
|
|
cpqSsBackplaneVendor, cpqSsBackplaneModel,
|
|
cpqSsBackplaneSerialNumber, cpqSsBackplaneFtpsStatus }
|
|
DESCRIPTION
|
|
"Storage system power supply status change.
|
|
|
|
The agent has detected a change in the power supply status of a
|
|
storage system. The variable cpqSsBackplaneFtpsStatus indicates
|
|
the current status.
|
|
|
|
User Action: If the power supply status is degraded, take action to
|
|
restore power or replace the failed power supply."
|
|
|
|
--#TYPE "Power Supply Status Change (8024)"
|
|
--#SUMMARY "Storage system power supply status changed to %d."
|
|
--#ARGUMENTS {8}
|
|
--#SEVERITY CRITICAL
|
|
--#TIMEINDEX 99
|
|
--#VARBINDSEVERITY 2
|
|
|
|
::= 8024
|
|
|
|
cpqSsExRecoveryServerStatusChange TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqSsChassisName,
|
|
cpqSsChassisTime, cpqSsChassisRsoStatus,
|
|
cpqSsChassisIndex }
|
|
DESCRIPTION
|
|
"Storage system recovery server option status change.
|
|
|
|
The agent has detected a change in the recovery server option
|
|
status of a storage system. The variable cpqSsChassisRsoStatus
|
|
indicates the current status.
|
|
|
|
User Action: If the RSO status is noSecondary(6) or linkDown(7),
|
|
insure the secondary server is operational and all cables are
|
|
connected properly. If the RSO status is secondaryRunningAuto(8)
|
|
or secondaryRunningUser(9), examine the the primary server for
|
|
failed components."
|
|
|
|
--#TYPE "Recovery Server Option Status Change (8025)"
|
|
--#SUMMARY "Storage system recovery server option status changed to %d."
|
|
--#ARGUMENTS {4}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 99
|
|
--#VARBINDSEVERITY 2
|
|
|
|
::= 8025
|
|
|
|
cpqSs5FanStatusChange TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqSsBoxCntlrHwLocation,
|
|
cpqSsBoxCntlrIndex, cpqSsBoxBusIndex, cpqSsBoxVendor,
|
|
cpqSsBoxModel, cpqSsBoxSerialNumber, cpqSsBoxFanStatus }
|
|
DESCRIPTION
|
|
"Storage System fan status change.
|
|
|
|
The agent has detected a change in the Fan Status of a storage
|
|
system. The variable cpqSsBoxFanStatus indicates the current
|
|
fan status.
|
|
|
|
User Action: If the fan status is degraded or failed, replace
|
|
any failed fans."
|
|
|
|
--#TYPE "Fan Status Change (8026)"
|
|
--#SUMMARY "Storage System fan status changed to %d."
|
|
--#ARGUMENTS {8}
|
|
--#SEVERITY CRITICAL
|
|
--#TIMEINDEX 99
|
|
|
|
::= 8026
|
|
|
|
cpqSs5TempStatusChange TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqSsBoxCntlrHwLocation,
|
|
cpqSsBoxCntlrIndex, cpqSsBoxBusIndex, cpqSsBoxVendor,
|
|
cpqSsBoxModel, cpqSsBoxSerialNumber, cpqSsBoxTempStatus }
|
|
DESCRIPTION
|
|
"Storage System temperature status change.
|
|
|
|
The agent has detected a change in the temperature status of a
|
|
storage system. The variable cpqSsBoxTempStatus indicates the
|
|
current temperature status.
|
|
|
|
User Action: If the temperature status is degraded or failed,
|
|
shutdown the storage system as soon as possible. Insure that
|
|
the storage system environment is being cooled properly and that
|
|
no components are overheated."
|
|
|
|
--#TYPE "Temperature Status Change (8027)"
|
|
--#SUMMARY "Storage System temperature status changed to %d."
|
|
--#ARGUMENTS {8}
|
|
--#SEVERITY CRITICAL
|
|
--#TIMEINDEX 99
|
|
|
|
::= 8027
|
|
|
|
cpqSs5PwrSupplyStatusChange TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqSsBoxCntlrHwLocation,
|
|
cpqSsBoxCntlrIndex, cpqSsBoxBusIndex, cpqSsBoxVendor,
|
|
cpqSsBoxModel, cpqSsBoxSerialNumber,
|
|
cpqSsBoxFltTolPwrSupplyStatus }
|
|
DESCRIPTION
|
|
"Storage system power supply status change.
|
|
|
|
The agent has detected a change in the power supply status of a
|
|
storage system. The variable cpqSsBoxFltTolPwrSupplyStatus
|
|
indicates the current power supply status.
|
|
|
|
User Action: If the power supply status is degraded, take action
|
|
to restore power or replace the failed power supply."
|
|
|
|
--#TYPE "Power Supply Status Change (8028)"
|
|
--#SUMMARY "Storage system power supply status changed to %d."
|
|
--#ARGUMENTS {8}
|
|
--#SEVERITY CRITICAL
|
|
--#TIMEINDEX 99
|
|
|
|
::= 8028
|
|
|
|
cpqSs6FanStatusChange TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqSsBoxCntlrHwLocation,
|
|
cpqSsBoxCntlrIndex, cpqSsBoxBusIndex, cpqSsBoxVendor,
|
|
cpqSsBoxModel, cpqSsBoxSerialNumber,
|
|
cpqSsBoxFanStatus, cpqSsBoxLocationString }
|
|
DESCRIPTION
|
|
"Storage System fan status change.
|
|
|
|
The agent has detected a change in the Fan Status of a storage
|
|
system. The variable cpqSsBoxFanStatus indicates the current
|
|
fan status.
|
|
|
|
User Action: If the fan status is degraded or failed, replace
|
|
any failed fans."
|
|
|
|
--#TYPE "Fan Status Change (8029)"
|
|
--#SUMMARY "Storage System fan status changed to %d."
|
|
--#ARGUMENTS {8}
|
|
--#SEVERITY CRITICAL
|
|
--#TIMEINDEX 99
|
|
--#VARBINDSEVERITY 2
|
|
|
|
::= 8029
|
|
|
|
cpqSs6TempStatusChange TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqSsBoxCntlrHwLocation,
|
|
cpqSsBoxCntlrIndex, cpqSsBoxBusIndex, cpqSsBoxVendor,
|
|
cpqSsBoxModel, cpqSsBoxSerialNumber,
|
|
cpqSsBoxTempStatus, cpqSsBoxLocationString }
|
|
DESCRIPTION
|
|
"Storage System temperature status change.
|
|
|
|
The agent has detected a change in the temperature status of a
|
|
storage system. The variable cpqSsBoxTempStatus indicates the
|
|
current temperature status.
|
|
|
|
User Action: If the temperature status is degraded or failed,
|
|
shutdown the storage system as soon as possible. Insure that
|
|
the storage system environment is being cooled properly and that
|
|
no components are overheated."
|
|
|
|
--#TYPE "Temperature Status Change (8030)"
|
|
--#SUMMARY "Storage System temperature status changed to %d."
|
|
--#ARGUMENTS {8}
|
|
--#SEVERITY CRITICAL
|
|
--#TIMEINDEX 99
|
|
--#VARBINDSEVERITY 2
|
|
|
|
::= 8030
|
|
|
|
cpqSs6PwrSupplyStatusChange TRAP-TYPE
|
|
ENTERPRISE compaq
|
|
VARIABLES { sysName, cpqHoTrapFlags, cpqSsBoxCntlrHwLocation,
|
|
cpqSsBoxCntlrIndex, cpqSsBoxBusIndex, cpqSsBoxVendor,
|
|
cpqSsBoxModel, cpqSsBoxSerialNumber,
|
|
cpqSsBoxFltTolPwrSupplyStatus, cpqSsBoxLocationString }
|
|
DESCRIPTION
|
|
"Storage system power supply status change.
|
|
|
|
The agent has detected a change in the power supply status of a
|
|
storage system. The variable cpqSsBoxFltTolPwrSupplyStatus
|
|
indicates the current power supply status.
|
|
|
|
User Action: If the power supply status is degraded, take action
|
|
to restore power or replace the failed power supply."
|
|
|
|
--#TYPE "Power Supply Status Change (8031)"
|
|
--#SUMMARY "Storage system power supply status changed to %d."
|
|
--#ARGUMENTS {8}
|
|
--#SEVERITY CRITICAL
|
|
--#TIMEINDEX 99
|
|
--#VARBINDSEVERITY 2
|
|
|
|
::= 8031
|
|
|
|
END
|