-- Dell Remote Access Controller (RAC) Management Information Base
-- Copyright (c) 2008 Dell Inc
--
-- Last Changed Revision: 10
-- Last Changed Date: 2008-07-25 17:23:34 -0500 (Fri, 25 Jul 2008)
-- Text Last Updated: 2008-10-03 11:18:53 -0500 (Fri, 03 Oct 2008)
--
DELL-RAC-MIB DEFINITIONS ::= BEGIN
IMPORTS
enterprises
FROM RFC1155-SMI
OBJECT-TYPE
FROM RFC-1212
TRAP-TYPE
FROM RFC-1215
DisplayString
FROM RFC1158-MIB;
-- text convention ------------------------------------------------------------------------
-------------------------------------------------------------------------------
-- This data type is used to model textual information taken
-- from the NVT ASCII character set. By convention, objects
-- with this syntax are declared as having
-- SIZE (0..1023)
-------------------------------------------------------------------------------
DellString ::= DisplayString (SIZE (0..1023))
DellRacType ::= INTEGER
{
other(1), -- the DRAC type is not one of the following
unknown(2), -- the DRAC type is unknown
DracIII(3), -- Drac III
ERA(4), -- ERA
DRAC4(5), -- Drac 4
DRAC5(6), -- Drac 5
DRAC5MC(7), -- Drac 5/MC
CMC(8), -- CMC
iDRAC(9) -- iDRAC
}
DellStatus ::= INTEGER
{
other(1), -- the status of the object is not one of the following:
unknown(2), -- the status of the object is unknown
-- (not known or monitored)
ok(3), -- the status of the object is ok
nonCritical(4), -- the status of the object is warning, non-critical
critical(5), -- the status of the object is critical (failure)
nonRecoverable(6) -- the status of the object is non-recoverable (dead)
}
-------------------------------------------------------------------------------
-- DellPowerReading is a string representation of a floating point value,
-- having exactly 3 digits of precision, and a maximum of 31 characters.
--
-- DellChassisPowerIndexRange defines the possible chassis power instances
-- in this MIB.
--
-- DellCMCPSUIndexRange defines the possible CMC Power Supply Unit (PSU)
-- instances, per chassis power instance, in this MIB.
--
-- DellCMCPSUCapable is an enumeration of PSU presence and/or monitoring
-- capabilities.
-------------------------------------------------------------------------------
DellPowerReading ::= DisplayString (SIZE (0..32))
DellCMCPowerIndexRange ::= INTEGER (1..1)
DellCMCPSUIndexRange ::= INTEGER (1..6)
DellCMCPSUCapable ::= INTEGER
{
absent(1), -- power supply is not present
none(2), -- no power monitoring abilities
basic(3) -- basic power monitoring abilities
}
-------------------------------------------------------------------------------
-- DellTimestamp is defined in the displayable format:
--
-- yyyymmddHHMMSS.uuuuuuDooo
--
-- where yyyy is the year, mm is the month number, dd is the day of the month,
-- HHMMSS are the hours, minutes and seconds, respectively, uuuuuu is the
-- number of microseconds, D is the UTC offset direction, and ooo is the
-- offset from UTC, in minutes.
--
-- Note: D is a plus (+) sign if east of UTC, and a minus (-) if west of UTC.
--
-- For example, Wednesday, May 25, 1994, at 1:30:15 PM EDT
-- would be represented as: 19940525133015.000000-300
-------------------------------------------------------------------------------
DellTimestamp ::= DisplayString (SIZE (26))
-- MIB Objects and Tables --------------------------------------------------------
dell OBJECT IDENTIFIER ::= { enterprises 674 }
server3 OBJECT IDENTIFIER ::= { dell 10892 }
drsOutofBandGroup OBJECT IDENTIFIER ::= { server3 2 }
drsInformationGroup OBJECT IDENTIFIER ::= { drsOutofBandGroup 1 }
drsProductInfoGroup OBJECT IDENTIFIER ::= { drsInformationGroup 1 }
drsFirmwareGroup OBJECT IDENTIFIER ::= { drsInformationGroup 2 }
drsStatusGroup OBJECT IDENTIFIER ::= { drsOutofBandGroup 2 }
drsChassisStatusGroup OBJECT IDENTIFIER ::= { drsOutofBandGroup 3 }
drsStatusNowGroup OBJECT IDENTIFIER ::= { drsChassisStatusGroup 1 }
drsStatusPrevGroup OBJECT IDENTIFIER ::= { drsChassisStatusGroup 2 }
drsStatusChangeGroup OBJECT IDENTIFIER ::= { drsChassisStatusGroup 3 }
drsChassisPowerGroup OBJECT IDENTIFIER ::= { drsOutofBandGroup 4 }
DrsCMCPowerTableEntry ::= SEQUENCE
{
drsChassisIndex DellCMCPowerIndexRange,
drsPotentialPower DellPowerReading,
drsIdlePower DellPowerReading,
drsMaxPowerSpecification DellPowerReading,
drsPowerSurplus DellPowerReading,
drsKWhCumulative DellPowerReading,
drsKWhCumulativeTime DellTimestamp,
drsWattsPeakUsage DellPowerReading,
drsWattsPeakTime DellTimestamp,
drsWattsMinUsage DellPowerReading,
drsWattsMinTime DellTimestamp,
drsWattsResetTime DellTimestamp,
drsWattsReading DellPowerReading,
drsAmpsReading DellPowerReading
}
DrsCMCPSUTableEntry ::= SEQUENCE
{
drsPSUChassisIndex DellCMCPowerIndexRange,
drsPSUIndex DellCMCPSUIndexRange,
drsPSULocation DellString,
drsPSUMonitoringCapable DellCMCPSUCapable,
drsPSUVoltsReading DellPowerReading,
drsPSUAmpsReading DellPowerReading,
drsPSUWattsReading DellPowerReading
}
drsCMCAlertGroup OBJECT IDENTIFIER ::= { drsOutofBandGroup 20 }
drsChassisAlertVariables OBJECT IDENTIFIER ::= { drsCMCAlertGroup 10 }
drsChassisAlertGroup OBJECT IDENTIFIER ::= { drsCMCAlertGroup 2000 }
drsAlertGroup OBJECT IDENTIFIER ::= { drsOutofBandGroup 5000 }
drsAlertVariables OBJECT IDENTIFIER ::= { drsAlertGroup 10 }
-- Variables and Traps ------------------------------------------------------------------------
-------------------------------------------------------------------------------
-- group: product information
-------------------------------------------------------------------------------
drsProductName OBJECT-TYPE
SYNTAX DellString
ACCESS read-only
STATUS mandatory
DESCRIPTION "0001.0001.0001 This attribute defines the product name of a chassis management controller."
::= { drsProductInfoGroup 1 }
drsProductShortName OBJECT-TYPE
SYNTAX DellString
ACCESS read-only
STATUS mandatory
DESCRIPTION "0001.0001.0002 This attribute defines the short product name of a chassis management controller. "
::= { drsProductInfoGroup 2 }
drsProductDescription OBJECT-TYPE
SYNTAX DellString
ACCESS read-only
STATUS mandatory
DESCRIPTION "0001.0001.0003 This attribute defines the product description of a chassis management controller. "
::= { drsProductInfoGroup 3 }
drsProductManufacturer OBJECT-TYPE
SYNTAX DellString
ACCESS read-only
STATUS mandatory
DESCRIPTION "0001.0001.0004 This attribute defines the product manufacturer of a chassis management controller. "
::= { drsProductInfoGroup 4 }
drsProductVersion OBJECT-TYPE
SYNTAX DellString
ACCESS read-only
STATUS mandatory
DESCRIPTION "0001.0001.0005 This attribute defines the product version of a chassis management controller. "
::= { drsProductInfoGroup 5 }
drsChassisServiceTag OBJECT-TYPE
SYNTAX DellString
ACCESS read-only
STATUS mandatory
DESCRIPTION "0001.0001.0007 This attribute defines the Service Tag of the chassis. "
::= { drsProductInfoGroup 6 }
drsProductURL OBJECT-TYPE
SYNTAX DellString
ACCESS read-only
STATUS mandatory
DESCRIPTION "0001.0001.0006 This attribute defines the out-of-band UI URL of a chassis management controller. "
::= { drsProductInfoGroup 7 }
drsProductChassisAssetTag OBJECT-TYPE
SYNTAX DellString
ACCESS read-only
STATUS mandatory
DESCRIPTION "0001.0001.0008 This attribute defines the Asset Tag of the chassis. "
::= { drsProductInfoGroup 8 }
drsProductChassisLocation OBJECT-TYPE
SYNTAX DellString
ACCESS read-only
STATUS mandatory
DESCRIPTION "0001.0001.0009 This attribute defines the location of the chassis. "
::= { drsProductInfoGroup 9 }
drsProductChassisName OBJECT-TYPE
SYNTAX DellString
ACCESS read-only
STATUS mandatory
DESCRIPTION "0001.0001.0010 This attribute defines the name of the chassis. "
::= { drsProductInfoGroup 10 }
drsSystemServiceTag OBJECT-TYPE
SYNTAX DellString
ACCESS read-only
STATUS mandatory
DESCRIPTION "0001.0001.0011 This attribute defines the service tag of a system. "
::= { drsProductInfoGroup 11 }
drsProductSystemAssetTag OBJECT-TYPE
SYNTAX DellString
ACCESS read-only
STATUS mandatory
DESCRIPTION "0001.0001.0012 This attribute defines the asset tag of a system. "
::= { drsProductInfoGroup 12 }
drsProductSystemSlot OBJECT-TYPE
SYNTAX DellString
ACCESS read-only
STATUS mandatory
DESCRIPTION "0001.0001.0013 This attribute defines the slot number of a CMC. "
::= { drsProductInfoGroup 13 }
drsProductType OBJECT-TYPE
SYNTAX DellRacType
ACCESS read-only
STATUS mandatory
DESCRIPTION "0001.0001.0014 This attribute defines type of a remote access card "
::= { drsProductInfoGroup 14 }
drsFirmwareVersion OBJECT-TYPE
SYNTAX DellString
ACCESS read-only
STATUS mandatory
DESCRIPTION "0001.0002.0001 This attribute defines the firmware version of a chassis management controller. "
::= { drsFirmwareGroup 1 }
-------------------------------------------------------------------------------
-- group: chassis status
-------------------------------------------------------------------------------
drsGlobalSystemStatus OBJECT-TYPE
SYNTAX DellStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION "0002.0001.0001 This attribute defines the overall chassis status
being monitored by the chassis management card."
::= { drsStatusGroup 1 }
drsGlobalCurrStatus OBJECT-TYPE
SYNTAX DellStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION "0003.0001.0001 This attribute defines the overall chassis status
being monitored by the chassis management card."
::= { drsStatusNowGroup 1 }
drsIOMCurrStatus OBJECT-TYPE
SYNTAX DellStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION "0003.0001.0002 This attribute defines the IOM subsystem status
being monitored by the chassis management card."
::= { drsStatusNowGroup 2 }
drsKVMCurrStatus OBJECT-TYPE
SYNTAX DellStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION "0003.0001.0003 This attribute defines the iKVM subsystem health status
being monitored by the chassis management card."
::= { drsStatusNowGroup 3 }
drsRedCurrStatus OBJECT-TYPE
SYNTAX DellStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION "0003.0001.0004 This attribute defines the Redundancy status
being monitored by the chassis management card."
::= { drsStatusNowGroup 4 }
drsPowerCurrStatus OBJECT-TYPE
SYNTAX DellStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION "0003.0001.0005 This attribute defines the power subsystem health status
being monitored by the chassis management card."
::= { drsStatusNowGroup 5 }
drsFanCurrStatus OBJECT-TYPE
SYNTAX DellStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION "0003.0001.0006 This attribute defines the Fan subsystem health status
being monitored by the chassis management card."
::= { drsStatusNowGroup 6 }
drsBladeCurrStatus OBJECT-TYPE
SYNTAX DellStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION "0003.0001.0007 This attribute defines the Blade subsystem health status
being monitored by the chassis management card."
::= { drsStatusNowGroup 7 }
drsTempCurrStatus OBJECT-TYPE
SYNTAX DellStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION "0003.0001.0008 This attribute defines the Temp Sensor subsystem health status
being monitored by the chassis management card."
::= { drsStatusNowGroup 8 }
drsCMCCurrStatus OBJECT-TYPE
SYNTAX DellStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION "0003.0001.0009 This attribute defines the CMC health status
being monitored by the chassis management card."
::= { drsStatusNowGroup 9 }
drsGlobalPrevStatus OBJECT-TYPE
SYNTAX DellStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION "0003.0002.0001 This attribute defines the previous chassis status
recorded by the chassis management card."
::= { drsStatusPrevGroup 1 }
drsIOMPrevStatus OBJECT-TYPE
SYNTAX DellStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION "0003.0002.0002 This attribute defines the previous IOM subsystem status
recorded by the chassis management card."
::= { drsStatusPrevGroup 2 }
drsKVMPrevStatus OBJECT-TYPE
SYNTAX DellStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION "0003.0002.0003 This attribute defines the previous iKVM subsystem health status
recorded by the chassis management card."
::= { drsStatusPrevGroup 3 }
drsRedPrevStatus OBJECT-TYPE
SYNTAX DellStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION "0003.0002.0004 This attribute defines the previous Redundancy status
recorded by the chassis management card."
::= { drsStatusPrevGroup 4 }
drsPowerPrevStatus OBJECT-TYPE
SYNTAX DellStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION "0003.0002.0005 This attribute defines the previous power subsystem health status
recorded by the chassis management card."
::= { drsStatusPrevGroup 5 }
drsFanPrevStatus OBJECT-TYPE
SYNTAX DellStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION "0003.0002.0006 This attribute defines the previous Fan health status
being monitored by the chassis management card."
::= { drsStatusPrevGroup 6 }
drsBladePrevStatus OBJECT-TYPE
SYNTAX DellStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION "0003.0002.0007 This attribute defines the previous Blade subsystem health status
recorded by the chassis management card."
::= { drsStatusPrevGroup 7 }
drsTempPrevStatus OBJECT-TYPE
SYNTAX DellStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION "0003.0001.0008 This attribute defines the Temp Sensor health status
being monitored by the chassis management card."
::= { drsStatusPrevGroup 8 }
drsCMCPrevStatus OBJECT-TYPE
SYNTAX DellStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION "0003.0001.0009 This attribute defines the CMC health status
being monitored by the chassis management card."
::= { drsStatusPrevGroup 9 }
drsGlobalChangeTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION "0003.0003.0001 This attribute defines the timestamp of the most recent
global status change."
::= { drsStatusChangeGroup 1 }
drsIOMChangeTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION "0003.0003.0002 This attribute defines the timestamp of the most recent
IOM status change."
::= { drsStatusChangeGroup 2 }
drsKVMChangeTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION "0003.0003.0003 This attribute defines the timestamp of the most recent
iKVM status change."
::= { drsStatusChangeGroup 3 }
drsRedChangeTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION "0003.0003.0004 This attribute defines the timestamp of the most recent
Redundancy status change."
::= { drsStatusChangeGroup 4 }
drsPowerChangeTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION "0003.0003.0005 This attribute defines the timestamp of the most recent
power health status change."
::= { drsStatusChangeGroup 5 }
drsFanChangeTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION "0003.0003.0006 This attribute defines the timestamp of the most recent
Fan health status change."
::= { drsStatusChangeGroup 6 }
drsBladeChangeTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION "0003.0003.0007 This attribute defines the timestamp of the most recent
Blade health status change."
::= { drsStatusChangeGroup 7 }
drsTempChangeTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION "0003.0003.0008 This attribute defines the timestamp of the most recent
Temp Sensor health status change."
::= { drsStatusChangeGroup 8 }
drsCMCChangeTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION "0003.0003.0009 This attribute defines the timestamp of the most recent
CMC health status change."
::= { drsStatusChangeGroup 9 }
-------------------------------------------------------------------------------
-- group: chassis power
-------------------------------------------------------------------------------
drsCMCPowerTable OBJECT-TYPE
SYNTAX SEQUENCE OF DrsCMCPowerTableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "0004.0001 This object defines the CMC power table."
::= { drsChassisPowerGroup 1 }
drsCMCPowerTableEntry OBJECT-TYPE
SYNTAX DrsCMCPowerTableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "0004.0001.0001 This object defines the CMC power table entry."
INDEX { drsChassisIndex }
::= { drsCMCPowerTable 1 }
drsCMCPSUTable OBJECT-TYPE
SYNTAX SEQUENCE OF DrsCMCPSUTableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "0004.0002 This object defines the CMC PSU table."
::= { drsChassisPowerGroup 2 }
drsCMCPSUTableEntry OBJECT-TYPE
SYNTAX DrsCMCPSUTableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "0004.0002.0001 This object defines the CMC PSU table entry."
INDEX { drsPSUChassisIndex, drsPSUIndex }
::= { drsCMCPSUTable 1 }
-------------------------------------------------------------------------------
-- table: CMC power information
-------------------------------------------------------------------------------
drsChassisIndex OBJECT-TYPE
SYNTAX DellCMCPowerIndexRange
ACCESS read-only
STATUS mandatory
DESCRIPTION "0004.0001.0001.0001 This attribute defines the index
(one-based) of the associated chassis."
::= { drsCMCPowerTableEntry 1 }
drsPotentialPower OBJECT-TYPE
SYNTAX DellPowerReading
ACCESS read-only
STATUS mandatory
DESCRIPTION "0004.0001.0001.0002 This attribute defines the power (in Watts) required by
the chassis infrastructure, plus the sum of the maximum power requirements
for all currently powered-on servers."
::= { drsCMCPowerTableEntry 2 }
drsIdlePower OBJECT-TYPE
SYNTAX DellPowerReading
ACCESS read-only
STATUS mandatory
DESCRIPTION "0004.0001.0001.0003 This attribute defines the power (in Watts) required by
the chassis infrastructure, plus the sum of the minimum power requirements
for all currently powered-on servers."
::= { drsCMCPowerTableEntry 3 }
drsMaxPowerSpecification OBJECT-TYPE
SYNTAX DellPowerReading
ACCESS read-only
STATUS mandatory
DESCRIPTION "0004.0001.0001.0004 This attribute defines the power limit (in Watts)
at which server throttling will take place."
::= { drsCMCPowerTableEntry 4 }
drsPowerSurplus OBJECT-TYPE
SYNTAX DellPowerReading
ACCESS read-only
STATUS mandatory
DESCRIPTION "0004.0001.0001.0005 This attribute defines the power surplus (in Watts)
remaining above the drsPotentialPower reading."
::= { drsCMCPowerTableEntry 5 }
drsKWhCumulative OBJECT-TYPE
SYNTAX DellPowerReading
ACCESS read-only
STATUS mandatory
DESCRIPTION "0004.0001.0001.0006 This attribute defines the cumulative chassis power
usage (in KWh) since last reset."
::= { drsCMCPowerTableEntry 6 }
drsKWhCumulativeTime OBJECT-TYPE
SYNTAX DellTimestamp
ACCESS read-only
STATUS mandatory
DESCRIPTION "0004.0001.0001.0007 This attribute defines the timestamp of the most recent
chassis power accumulator reset."
::= { drsCMCPowerTableEntry 7 }
drsWattsPeakUsage OBJECT-TYPE
SYNTAX DellPowerReading
ACCESS read-only
STATUS mandatory
DESCRIPTION "0004.0001.0001.0008 This attribute defines the chassis peak power
usage (in Watts) since last reset."
::= { drsCMCPowerTableEntry 8 }
drsWattsPeakTime OBJECT-TYPE
SYNTAX DellTimestamp
ACCESS read-only
STATUS mandatory
DESCRIPTION "0004.0001.0001.0009 This attribute defines the timestamp of the most recent
chassis peak power usage."
::= { drsCMCPowerTableEntry 9 }
drsWattsMinUsage OBJECT-TYPE
SYNTAX DellPowerReading
ACCESS read-only
STATUS mandatory
DESCRIPTION "0004.0001.0001.0010 This attribute defines the chassis mimimum power
usage (in Watts) since last reset."
::= { drsCMCPowerTableEntry 10 }
drsWattsMinTime OBJECT-TYPE
SYNTAX DellTimestamp
ACCESS read-only
STATUS mandatory
DESCRIPTION "0004.0001.0001.0011 This attribute defines the timestamp of the most recent
chassis minimum power usage."
::= { drsCMCPowerTableEntry 11 }
drsWattsResetTime OBJECT-TYPE
SYNTAX DellTimestamp
ACCESS read-only
STATUS mandatory
DESCRIPTION "0004.0001.0001.0012 This attribute defines the timestamp of the most recent
reset of the chassis min/peak Watts readings."
::= { drsCMCPowerTableEntry 12 }
drsWattsReading OBJECT-TYPE
SYNTAX DellPowerReading
ACCESS read-only
STATUS mandatory
DESCRIPTION "0004.0001.0001.0013 This attribute defines the instantaneous chassis power
usage (in Watts)."
::= { drsCMCPowerTableEntry 13 }
drsAmpsReading OBJECT-TYPE
SYNTAX DellPowerReading
ACCESS read-only
STATUS mandatory
DESCRIPTION "0004.0001.0001.0014 This attribute defines the instantaneous chassis current
usage (in Watts)."
::= { drsCMCPowerTableEntry 14 }
-------------------------------------------------------------------------------
-- table: CMC PSU info
-------------------------------------------------------------------------------
drsPSUChassisIndex OBJECT-TYPE
SYNTAX DellCMCPowerIndexRange
ACCESS read-only
STATUS mandatory
DESCRIPTION "0004.0002.0001.0001 This attribute defines the index
(one-based) of the associated chassis."
::= { drsCMCPSUTableEntry 1 }
drsPSUIndex OBJECT-TYPE
SYNTAX DellCMCPSUIndexRange
ACCESS read-only
STATUS mandatory
DESCRIPTION "0004.0002.0001.0002 This attribute defines the index
(one-based) of the associated CMC PSU."
::= { drsCMCPSUTableEntry 2 }
drsPSULocation OBJECT-TYPE
SYNTAX DellString
ACCESS read-only
STATUS mandatory
DESCRIPTION "0004.0002.0001.0003 This attribute defines the location
of the CMC PSU."
::= { drsCMCPSUTableEntry 3 }
drsPSUMonitoringCapable OBJECT-TYPE
SYNTAX DellCMCPSUCapable
ACCESS read-only
STATUS mandatory
DESCRIPTION "0004.0002.0001.0004 This attribute defines the PSU Monitoring
capabilities, or the absence of a PSU in this location."
::= { drsCMCPSUTableEntry 4 }
drsPSUVoltsReading OBJECT-TYPE
SYNTAX DellPowerReading
ACCESS read-only
STATUS mandatory
DESCRIPTION "0004.0002.0001.0005 This attribute defines the instantaneous
PSU Voltage reading."
::= { drsCMCPSUTableEntry 5 }
drsPSUAmpsReading OBJECT-TYPE
SYNTAX DellPowerReading
ACCESS read-only
STATUS mandatory
DESCRIPTION "0004.0002.0001.0006 This attribute defines the instantaneous
PSU Current reading."
::= { drsCMCPSUTableEntry 6 }
drsPSUWattsReading OBJECT-TYPE
SYNTAX DellPowerReading
ACCESS read-only
STATUS mandatory
DESCRIPTION "0004.0002.0001.0007 This attribute defines the instantaneous
PSU Wattage reading."
::= { drsCMCPSUTableEntry 7 }
-------------------------------------------------------------------------------
-- group: chassis alerts
-------------------------------------------------------------------------------
drsCASubSystem OBJECT-TYPE
SYNTAX DellString
ACCESS read-only
STATUS mandatory
DESCRIPTION "0020.0010.0001 This attribute defines the Sub-System Name of the CMC Alert"
::= { drsChassisAlertVariables 1 }
drsCASSCurrStatus OBJECT-TYPE
SYNTAX DellStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION "0020.0010.0002 This attribute defines the Current Status of the Alerting
Sub-System"
::= { drsChassisAlertVariables 2 }
drsCASSPrevStatus OBJECT-TYPE
SYNTAX DellStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION "0020.0010.0003 This attribute defines the Previous Status of the Alerting
Sub-System"
::= { drsChassisAlertVariables 3 }
drsCASSChangeTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION "0020.0010.0004 This attribute defines the Timestamp of Most Recent Change of
the Alerting Sub-System"
::= { drsChassisAlertVariables 4 }
drsCAMessage OBJECT-TYPE
SYNTAX DellString
ACCESS read-only
STATUS mandatory
DESCRIPTION "0020.0010.0005 This attribute defines the CSSD message of the CMC Alert"
::= { drsChassisAlertVariables 5 }
alertCMCTestTrap TRAP-TYPE
ENTERPRISE drsOutofBandGroup
DESCRIPTION "The CMC has generated a test trap"
--#TYPE "CMC Test Trap"
--#SUMMARY "CMC Test Trap"
--#SEVERITY INFORMATIONAL
--#CATEGORY Error Events
::= 2000
alertCMCNormalTrap TRAP-TYPE
ENTERPRISE drsOutofBandGroup
VARIABLES { drsProductChassisName,
drsProductChassisLocation,
drsGlobalCurrStatus,
drsCASubSystem,
drsCASSCurrStatus,
drsCASSPrevStatus,
drsCASSChangeTime,
drsCAMessage }
DESCRIPTION "The CMC reported a return-to-normal or informational event."
--#TYPE "CMC Return-to-Normal / Informational Trap"
--#SUMMARY "Return-to-Normal / Informational Trap from CMC in system %s in location %s, message: %s"
--#ARGUMENTS {0,1,7}
--#SEVERITY NORMAL
--#CATEGORY Error Events
::= 2002
alertCMCWarningTrap TRAP-TYPE
ENTERPRISE drsOutofBandGroup
VARIABLES { drsProductChassisName,
drsProductChassisLocation,
drsGlobalCurrStatus,
drsCASubSystem,
drsCASSCurrStatus,
drsCASSPrevStatus,
drsCASSChangeTime,
drsCAMessage }
DESCRIPTION "The CMC reported a warning event."
--#TYPE "CMC Warning Trap"
--#SUMMARY "Warning Trap from CMC in system %s in location %s, message: %s"
--#ARGUMENTS {0,1,7}
--#SEVERITY WARNING
--#CATEGORY Error Events
::= 2003
alertCMCCriticalTrap TRAP-TYPE
ENTERPRISE drsOutofBandGroup
VARIABLES { drsProductChassisName,
drsProductChassisLocation,
drsGlobalCurrStatus,
drsCASubSystem,
drsCASSCurrStatus,
drsCASSPrevStatus,
drsCASSChangeTime,
drsCAMessage }
DESCRIPTION "The CMC reported a critical event."
--#TYPE "CMC Critical Trap"
--#SUMMARY "Critical Trap from CMC in system %s in location %s, message: %s"
--#ARGUMENTS {0,1,7}
--#SEVERITY CRITICAL
--#CATEGORY Error Events
::= 2004
alertCMCNonRecoverableTrap TRAP-TYPE
ENTERPRISE drsOutofBandGroup
VARIABLES { drsProductChassisName,
drsProductChassisLocation,
drsGlobalCurrStatus,
drsCASubSystem,
drsCASSCurrStatus,
drsCASSPrevStatus,
drsCASSChangeTime,
drsCAMessage }
DESCRIPTION "The CMC reported a catastrophic event."
--#TYPE "CMC Non-Recoverable Trap"
--#SUMMARY "Non-Recoverable Trap from CMC in system %s in location %s, message: %s"
--#ARGUMENTS {0,1,7}
--#SEVERITY NON-RECOVERABLE
--#CATEGORY Error Events
::= 2005
--
-- Legacy Alerting
--
drsAlertSystem OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"5000.0010.0001 Name of the system generating the alert."
--DEFAULT get-function-async get_%n_async
--DEFAULT next-function-async std_next_async
::= { drsAlertVariables 1 }
drsAlertTableIndexOID OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"5000.0010.0002 0.0"
--DEFAULT get-function-async get_OID_null_async
--DEFAULT next-function-async std_next_async
::= { drsAlertVariables 2 }
drsAlertMessage OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..1024))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"5000.0010.0003 Message describing the alert."
--DEFAULT get-function-async get_string_null_async
--DEFAULT next-function-async std_next_async
::= { drsAlertVariables 3 }
drsAlertCurrentStatus OBJECT-TYPE
SYNTAX DellStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION
"5000.0010.0004 Current status of object causing the alert."
--DEFAULT get-function-async get_dellstatus_unknow_async
--DEFAULT next-function-async std_next_async
::= { drsAlertVariables 4 }
drsAlertPreviousStatus OBJECT-TYPE
SYNTAX DellStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION
"5000.0010.0005 Previous status of object causing the alert."
--DEFAULT get-function-async get_dellstatus_unknow_async
--DEFAULT next-function-async std_next_async
::= { drsAlertVariables 5 }
drsAlertData OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..1024))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"5000.0010.0006 Alert data."
--DEFAULT get-function-async get_string_null_async
--DEFAULT next-function-async std_next_async
::= { drsAlertVariables 6 }
alertDrscTestTrapEvent TRAP-TYPE
ENTERPRISE drsOutofBandGroup
VARIABLES { drsAlertSystem,
drsAlertTableIndexOID,
drsAlertMessage,
drsAlertCurrentStatus,
drsAlertPreviousStatus,
drsAlertData }
DESCRIPTION
"The RAC generated a test trap event in response to a user request."
--#TYPE "Dell RAC Test TRAP Event"
--#SUMMARY "%s"
--#ARGUMENTS {2}
--#SEVERITY INFORMATIONAL
--#CATEGORY Status Events
::= 1001
alertDrscAuthError TRAP-TYPE
ENTERPRISE drsOutofBandGroup
VARIABLES { drsAlertSystem,
drsAlertTableIndexOID,
drsAlertMessage,
drsAlertCurrentStatus,
drsAlertPreviousStatus,
drsAlertData }
DESCRIPTION
"The RAC Authentication Failures during a time period have Exceeded a Threshold."
--#TYPE "Dell RAC Authentication Error"
--#SUMMARY "%s"
--#ARGUMENTS {2}
--#SEVERITY MINOR
--#CATEGORY Error Events
::= 1002
alertDrscLostESM TRAP-TYPE
ENTERPRISE drsOutofBandGroup
VARIABLES { drsAlertSystem,
drsAlertTableIndexOID,
drsAlertMessage,
drsAlertCurrentStatus,
drsAlertPreviousStatus,
drsAlertData }
DESCRIPTION
"The RAC cannot communicate with the baseboard management controller (ESM)."
--#TYPE "Dell RAC Lost Communication with ESM"
--#SUMMARY "%s"
--#ARGUMENTS {2}
--#SEVERITY MINOR
--#CATEGORY Error Events
::= 1003
alertDrscFoundESM TRAP-TYPE
ENTERPRISE drsOutofBandGroup
VARIABLES { drsAlertSystem,
drsAlertTableIndexOID,
drsAlertMessage,
drsAlertCurrentStatus,
drsAlertPreviousStatus,
drsAlertData }
DESCRIPTION
"The RAC is communicating normally with the baseboard management controller (ESM)."
--#TYPE "Dell RAC Communication with ESM is OK"
--#SUMMARY "%s"
--#ARGUMENTS {2}
--#SEVERITY INFORMATIONAL
--#CATEGORY Error Events
::= 1004
alertDrscPowerOff TRAP-TYPE
ENTERPRISE drsOutofBandGroup
VARIABLES { drsAlertSystem,
drsAlertTableIndexOID,
drsAlertMessage,
drsAlertCurrentStatus,
drsAlertPreviousStatus,
drsAlertData }
DESCRIPTION
"The RAC has detected a System power state change to powered-off."
--#TYPE "Dell RAC Detected System Powered-Off"
--#SUMMARY "%s"
--#ARGUMENTS {2}
--#SEVERITY CRITICAL
--#CATEGORY Error Events
::= 1005
alertDrscPowerOn TRAP-TYPE
ENTERPRISE drsOutofBandGroup
VARIABLES { drsAlertSystem,
drsAlertTableIndexOID,
drsAlertMessage,
drsAlertCurrentStatus,
drsAlertPreviousStatus,
drsAlertData }
DESCRIPTION
"The RAC has detected a system power state change to powered-on."
--#TYPE "Dell RAC Detected System Powered-On"
--#SUMMARY "%s"
--#ARGUMENTS {2}
--#SEVERITY INFORMATIONAL
--#CATEGORY Error Events
::= 1006
alertDrscWatchdogExpired TRAP-TYPE
ENTERPRISE drsOutofBandGroup
VARIABLES { drsAlertSystem,
drsAlertTableIndexOID,
drsAlertMessage,
drsAlertCurrentStatus,
drsAlertPreviousStatus,
drsAlertData }
DESCRIPTION
"The RAC has detected that the system watchdog has expired indicating a system hang."
--#TYPE "Dell RAC Detected Watchdog Expired"
--#SUMMARY "%s"
--#ARGUMENTS {2}
--#SEVERITY CRITICAL
--#CATEGORY Error Events
::= 1007
alertDrscBattLow TRAP-TYPE
ENTERPRISE drsOutofBandGroup
VARIABLES { drsAlertSystem,
drsAlertTableIndexOID,
drsAlertMessage,
drsAlertCurrentStatus,
drsAlertPreviousStatus,
drsAlertData }
DESCRIPTION
"The RAC Battery charge is below 25% indicating that the battery may only be able to power the DRSC for 8-10 minutes."
--#TYPE "Dell RAC Battery Charge Low"
--#SUMMARY "%s"
--#ARGUMENTS {2}
--#SEVERITY MINOR
--#CATEGORY Error Events
::= 1008
alertDrscTempNormal TRAP-TYPE
ENTERPRISE drsOutofBandGroup
VARIABLES { drsAlertSystem,
drsAlertTableIndexOID,
drsAlertMessage,
drsAlertCurrentStatus,
drsAlertPreviousStatus,
drsAlertData }
DESCRIPTION
"The RAC Temperature probe has retured to a normal value."
--#TYPE "Dell RAC Temperature Normal"
--#SUMMARY "%s"
--#ARGUMENTS {2}
--#SEVERITY INFORMATIONAL
--#CATEGORY Error Events
::= 1009
alertDrscTempWarning TRAP-TYPE
ENTERPRISE drsOutofBandGroup
VARIABLES { drsAlertSystem,
drsAlertTableIndexOID,
drsAlertMessage,
drsAlertCurrentStatus,
drsAlertPreviousStatus,
drsAlertData }
DESCRIPTION
"The RAC Temperature probe has detected a Warning value."
--#TYPE "Dell RAC Temperature Warning"
--#SUMMARY "%s"
--#ARGUMENTS {2}
--#SEVERITY MINOR
--#CATEGORY Error Events
::= 1010
alertDrscTempCritical TRAP-TYPE
ENTERPRISE drsOutofBandGroup
VARIABLES { drsAlertSystem,
drsAlertTableIndexOID,
drsAlertMessage,
drsAlertCurrentStatus,
drsAlertPreviousStatus,
drsAlertData }
DESCRIPTION
"The RAC Temperature probe has detected a failure (or critical) value."
--#TYPE "Dell RAC Temperature Failure"
--#SUMMARY "%s"
--#ARGUMENTS {2}
--#SEVERITY CRITICAL
--#CATEGORY Error Events
::= 1011
alertDrscVoltNormal TRAP-TYPE
ENTERPRISE drsOutofBandGroup
VARIABLES { drsAlertSystem,
drsAlertTableIndexOID,
drsAlertMessage,
drsAlertCurrentStatus,
drsAlertPreviousStatus,
drsAlertData }
DESCRIPTION
"The RAC voltage has returned to a normal value."
--#TYPE "Dell RAC Voltage Normal"
--#SUMMARY "%s"
--#ARGUMENTS {2}
--#SEVERITY INFORMATIONAL
--#CATEGORY Error Events
::= 1012
alertDrscVoltWarning TRAP-TYPE
ENTERPRISE drsOutofBandGroup
VARIABLES { drsAlertSystem,
drsAlertTableIndexOID,
drsAlertMessage,
drsAlertCurrentStatus,
drsAlertPreviousStatus,
drsAlertData }
DESCRIPTION
"The RAC voltage probe has detected a warning value."
--#TYPE "Dell RAC Battery Warning"
--#SUMMARY "%s"
--#ARGUMENTS {2}
--#SEVERITY MINOR
--#CATEGORY Error Events
::= 1013
alertDrscVoltCritical TRAP-TYPE
ENTERPRISE drsOutofBandGroup
VARIABLES { drsAlertSystem,
drsAlertTableIndexOID,
drsAlertMessage,
drsAlertCurrentStatus,
drsAlertPreviousStatus,
drsAlertData }
DESCRIPTION
"The RAC voltage probe has detected a failure (or critical) value."
--#TYPE "Dell RAC Voltage Failure"
--#SUMMARY "%s"
--#ARGUMENTS {2}
--#SEVERITY CRITICAL
--#CATEGORY Error Events
::= 1014
alertDrscSELWarning TRAP-TYPE
ENTERPRISE drsOutofBandGroup
VARIABLES { drsAlertSystem,
drsAlertTableIndexOID,
drsAlertMessage,
drsAlertCurrentStatus,
drsAlertPreviousStatus,
drsAlertData }
DESCRIPTION
"The RAC has detected a new event in the System Event Log with Severity: Warning."
--#TYPE "Dell RAC System Event Log Warning"
--#SUMMARY "%s"
--#ARGUMENTS {2}
--#SEVERITY MAJOR
--#CATEGORY Error Events
::= 1015
alertDrscSELCritical TRAP-TYPE
ENTERPRISE drsOutofBandGroup
VARIABLES { drsAlertSystem,
drsAlertTableIndexOID,
drsAlertMessage,
drsAlertCurrentStatus,
drsAlertPreviousStatus,
drsAlertData }
DESCRIPTION
"The RAC has detected a new event in the System Event Log with Severity: Critical."
--#TYPE "Dell RAC System Event Log Critical"
--#SUMMARY "%s"
--#ARGUMENTS {2}
--#SEVERITY CRITICAL
--#CATEGORY Error Events
::= 1016
alertDrscSEL80percentFull TRAP-TYPE
ENTERPRISE drsOutofBandGroup
VARIABLES { drsAlertSystem,
drsAlertTableIndexOID,
drsAlertMessage,
drsAlertCurrentStatus,
drsAlertPreviousStatus,
drsAlertData }
DESCRIPTION
"The RAC has detected that the System Event Log is 80% full."
--#TYPE "Dell System Event Log 80% Full Warning"
--#SUMMARY "%s"
--#ARGUMENTS {2}
--#SEVERITY MAJOR
--#CATEGORY Status Events
::= 1017
alertDrscSEL90percentFull TRAP-TYPE
ENTERPRISE drsOutofBandGroup
VARIABLES { drsAlertSystem,
drsAlertTableIndexOID,
drsAlertMessage,
drsAlertCurrentStatus,
drsAlertPreviousStatus,
drsAlertData }
DESCRIPTION
"The RAC has detected that the System Event Log is 90% full."
--#TYPE " Dell System Event Log 90% Full Warning "
--#SUMMARY "%s"
--#ARGUMENTS {2}
--#SEVERITY MAJOR
--#CATEGORY Status Events
::= 1018
alertDrscSEL100percentFull TRAP-TYPE
ENTERPRISE drsOutofBandGroup
VARIABLES { drsAlertSystem,
drsAlertTableIndexOID,
drsAlertMessage,
drsAlertCurrentStatus,
drsAlertPreviousStatus,
drsAlertData }
DESCRIPTION
"The RAC has detected that the System Event Log is 100% full."
--#TYPE " Dell System Event Log 100% Full Warning "
--#SUMMARY "%s"
--#ARGUMENTS {2}
--#SEVERITY MAJOR
--#CATEGORY Status Events
::= 1019
alertDrscSELNormal TRAP-TYPE
ENTERPRISE drsOutofBandGroup
VARIABLES { drsAlertSystem,
drsAlertTableIndexOID,
drsAlertMessage,
drsAlertCurrentStatus,
drsAlertPreviousStatus,
drsAlertData }
DESCRIPTION
"The RAC has detected a new event in the System Event Log with Severity: Normal."
--#TYPE "Dell RAC System Event Log Normal"
--#SUMMARY "%s"
--#ARGUMENTS {2}
--#SEVERITY INFORMATIONAL
--#CATEGORY Error Events
::= 1020
END