pandorafms/pandora_console/attachment/mibs/RAPID-CITY.mib

4650 lines
164 KiB
Plaintext

RAPID-CITY DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, Gauge32, Counter32, Integer32,
enterprises, IpAddress, TimeTicks
FROM SNMPv2-SMI
TEXTUAL-CONVENTION, RowStatus, TruthValue, MacAddress, DisplayString
FROM SNMPv2-TC
InterfaceIndex
FROM IF-MIB
SnmpAdminString,SnmpSecurityLevel,SnmpSecurityModel
FROM SNMP-FRAMEWORK-MIB
InetAddressType, InetAddress, InetPortNumber, InetAddressPrefixLength
FROM INET-ADDRESS-MIB
Ipv6Address
FROM IPV6-TC;
rapidCity MODULE-IDENTITY
LAST-UPDATED "200510210000Z"
ORGANIZATION "Bay Networks, Rapid-City Group"
CONTACT-INFO "Yu-Ten Lee
Postal: Nortel Networks, Inc.
4655 Great America Parkway
Santa Clara, CA 95052-8185
Tel: 408-495-2560
Fax: 408-495-6680
E-mail: ylee@baynetworks.com"
DESCRIPTION "Enterprise MIB for the Accelar product family."
REVISION "200510210000Z"
DESCRIPTION "Verion 46: Added new mibs rcFlowClassifier for 1600"
REVISION "200509300000Z" -- 30 Sep 2005
DESCRIPTION "Version 45: Modified rcSysDnsServerListTable, sorted objects in rcChassis, & added rcChasSystemMonitorEnable"
REVISION "200509200000Z" -- 20 Sep 2005
DESCRIPTION "Version 44: Added Ipv6 attributes to various tables"
REVISION "200509090000Z" -- 09 Sep 2005
DESCRIPTION "Version 43: Added rcSysVirtualIpv6PrefixLength & rcSysVirtualIpv6Addr"
REVISION "200508290000Z" -- 29 Aug 2005
DESCRIPTION "Version 42: Added rcIsis & rcSlpp"
REVISION "200507270000Z" -- 27 July 2005
DESCRIPTION "Version 41. Increased range for rcCardIndex"
REVISION "200507190000Z" -- 19 Jul 2005
DESCRIPTION "Version 40. Added rcSysAccPolSnmpGrpTable.Included snmp-v3 under
access policy service, removed the default value"
REVISION "200506020000Z" -- 02 Jun 2005
DESCRIPTION "Version 39. Added rcChasMcastCheckPktEnable."
REVISION "200505060000Z" -- 06 May 2005
DESCRIPTION "Version 39. Added rcSysFrcMsgControlTable."
REVISION "200504270000Z" -- 27 Apr 2005
DESCRIPTION "Version 38. Allow 0 length rsa and dsa key sizes."
REVISION "200504210000Z" -- 21 Apr 2005
DESCRIPTION "Version 37. Fixed typos, added rcIpfix."
REVISION "200504140000Z" -- 14 Apr 2005
DESCRIPTION "Version 36. Modified rcSysAccessPolicyService &
rcSyslogHostSeverity mib objects."
REVISION "200503210000Z" -- 21 Mar 2005
DESCRIPTION "Version 35: added rcLacpGlobalVlacpMulticastMACAddress."
REVISION "200502220000Z" -- 22 Feb 2005
DESCRIPTION "Version 34: Changed PortSet definition"
REVISION "200502181200Z" -- 18 Feb 2005
DESCRIPTION "Version 33: Added support for Tacacs"
REVISION "200502171200Z" -- 17 Feb 2005
DESCRIPTION "Version 32: Updated teritory to tertiary"
REVISION "200502150000Z" -- 15 Feb 2005
DESCRIPTION "Version 31: Added rcEsu1800dc"
REVISION "200502110000Z" -- 11 Feb 2005
DESCRIPTION "Version 30: Added rcSystem 92 & 93"
REVISION "200502040000Z" -- 04 Feb 2005
DESCRIPTION "Version 29: Changed range of rcSysVersion, rcCardSerialNumber,
rcChasPowerSupplyDetailSerialNumber,
rcChasPowerSupplyDetailHardwareRevision,
rcChasPowerSupplyDetailPartNumber,
rcCardSerialNumber"
REVISION "200501160000Z" -- 16 January 2005
DESCRIPTION "Version 28: Added rcSysPowerUsage and rcSysPowerAvailable"
REVISION "200412210000Z" -- 21 December 2004
DESCRIPTION "Version 27: Deprecated rcSysAction. Added
rcSysExtCplimitSysOctapidCongested,
rcSysExtCplimitPortsMonitored,
rcSysExtCplimitPortsShutDown,
rcSysActionL1, rcSysActionL2,
rcSysActionL3, rcSysActionRwa "
REVISION "200411230000Z" -- 23 November 2004
DESCRIPTION "Version 26: Added rcEsu1850 and rcEsu1850dc for ESU device"
REVISION "200411110000Z" -- 11 November 2004
DESCRIPTION "Version 25: Cleaned up REVISIONs and fixed typo."
REVISION "200411040000Z" -- 04 November 2004
DESCRIPTION "Version 24: Added rcSysExtCplimitEnable,rcSysExtCplimitMinCongTime,
rcSysExtCplimitMaxPorts, rcSysExtCplimitPortCongTime,
rcSysExtCplimitTrapLevel."
REVISION "200409300000Z" -- 30 September 2004
DESCRIPTION "Version 22: Fixed type mismatch for mib
rcSysDnsServerListRequestCount/SuccessCount"
REVISION "200409280000Z" -- 28 September 2004
DESCRIPTION "Version 21: Update enum value for mib rcSysDnsServerListType,
update syntax type for RequestCount, SuccessCount,
change rcRepeaterTable OID and add new mib
rcChasNewGlobalFilterOrderingEnable."
REVISION "200409230000Z" -- 23 September 2004
DESCRIPTION "Version 20: Add range for rcAgentId."
REVISION "200409210000Z" -- 21 September 2004
DESCRIPTION "Version 19: Remove range for rcAgentId."
REVISION "200409130001Z" -- 13 September 2004
DESCRIPTION "Version 18: Added rcCliRWEnable, rcCliRWL1Enable, rcCliRWL2Enable,
rcCliRWL3Enable, rcCliROEnable."
REVISION "200409130000Z" -- 13 September 2004
DESCRIPTION "Version 17: Added rcSysAutoRecoverDelay, rcSysMacFlapLimitTime,
rcSysMacFlapLimitCount"
REVISION "200408310000Z" -- 31 August 2004
DESCRIPTION "Version 16: Change rcVlacpPeerMacAddressMltIds to
rcVlacpPeerMacAddressMltId with SYNTAX INTEGER and
rcVlacpPeerMacAddressPort with SYNTAX InterfaceIndex"
REVISION "200407070000Z" -- 07 July 2004
DESCRIPTION "Version 15: Added rcVlacpPeerMacAddressTable"
REVISION "200407060000Z" -- 06 July 2004
DESCRIPTION "Version 14: Added Poe card type poe1400WPS(0x109e3100)"
REVISION "200406240000Z" -- 24 June 2004
DESCRIPTION "Version 13: Added rcSysSpanningTreeOperMode and
rcSysSpanningTreeAdminMode"
REVISION "200406110000Z" -- 11 June 2004
DESCRIPTION "Version 12: Added rcChasRspMode, rcChasRspOperMode,
and rcChasRspModeError objects"
::= { enterprises 2272 }
--
-- Textual Conventions
--
EnableValue ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "Enable/Disable value."
SYNTAX INTEGER { enable(1), disable(2) }
PortSet ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The string is 88 octets long, for a total of 704 bits. Each bit
corresponds to a port, as represented by its ifIndex value . When a
bit has the value one(1), the corresponding port is a member of the
set. When a bit has the value zero(0), the corresponding port is not
a member of the set. The encoding is such that the most significant
bit of octet #1 corresponds to ifIndex 0, while the least significant
bit of octet #88 corresponds to ifIndex 703. In order to accommodate
future uses of this the string has a max size of 255 bytes."
SYNTAX OCTET STRING (SIZE (0..255))
IdList ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION ""
SYNTAX OCTET STRING (SIZE(0..8192))
--
-- Enterprise specific MIB groups
--
rcMgmt OBJECT IDENTIFIER ::= { rapidCity 1 }
rcA1100 OBJECT IDENTIFIER ::= { rapidCity 2 }
rcA1250 OBJECT IDENTIFIER ::= { rapidCity 6 }
rcA1150 OBJECT IDENTIFIER ::= { rapidCity 7 }
rcA1200 OBJECT IDENTIFIER ::= { rapidCity 8 }
rcA1050 OBJECT IDENTIFIER ::= { rapidCity 9 }
rcA740 OBJECT IDENTIFIER ::= { rapidCity 20 }
rcA750 OBJECT IDENTIFIER ::= { rapidCity 21 }
rcA790 OBJECT IDENTIFIER ::= { rapidCity 22 }
rcA750S OBJECT IDENTIFIER ::= { rapidCity 23 }
rcA8003 OBJECT IDENTIFIER ::= { rapidCity 280887555 }
rcA8006 OBJECT IDENTIFIER ::= { rapidCity 280887558 }
rcA8010 OBJECT IDENTIFIER ::= { rapidCity 280887562 }
rcA8010co OBJECT IDENTIFIER ::= { rapidCity 1623064842 }
rcA8610 OBJECT IDENTIFIER ::= { rapidCity 30 }
rcA8606 OBJECT IDENTIFIER ::= { rapidCity 31 }
rcA8110 OBJECT IDENTIFIER ::= { rapidCity 32 }
rcA8106 OBJECT IDENTIFIER ::= { rapidCity 33 }
rcA8603 OBJECT IDENTIFIER ::= { rapidCity 34 }
rcA8103 OBJECT IDENTIFIER ::= { rapidCity 35 }
rcA8110co OBJECT IDENTIFIER ::= { rapidCity 36 }
rcA8610co OBJECT IDENTIFIER ::= { rapidCity 37 }
-- This is a place holder for OM 2.0 chassises
-- NOTE that { rapidCity 40 } is also used for the rcBayStack branch,
-- and so we must be sure that nothing ever gets defined under rcAom8003
-- in order to avoid any conflicts.
--rcAom8010 OBJECT IDENTIFIER ::= { rapidCity 38 }
--rcAom8010co OBJECT IDENTIFIER ::= { rapidCity 39 }
rcBayStack OBJECT IDENTIFIER ::= { rapidCity 40 }
--rcAom8006 OBJECT IDENTIFIER ::= { rapidCity 41 }
rcA1424 OBJECT IDENTIFIER ::= { rapidCity 42 }
rcA1648 OBJECT IDENTIFIER ::= { rapidCity 43 }
rcA1612 OBJECT IDENTIFIER ::= { rapidCity 44 }
rcA1624 OBJECT IDENTIFIER ::= { rapidCity 45 }
rcRBS2402 OBJECT IDENTIFIER ::= { rapidCity 46 }
rcAtr8310 OBJECT IDENTIFIER ::= { rapidCity 47 }
rcAtr8306 OBJECT IDENTIFIER ::= { rapidCity 48 }
rcAtr8010 OBJECT IDENTIFIER ::= { rapidCity 49 }
rcAtr8006 OBJECT IDENTIFIER ::= { rapidCity 50 }
rcEsu1850 OBJECT IDENTIFIER ::= { rapidCity 51 }
rcEsu1850dc OBJECT IDENTIFIER ::= { rapidCity 52 }
rcEsu1800dc OBJECT IDENTIFIER ::= { rapidCity 53 }
-- From rapidCity 100 to rapidCity 200 is reserved for OM chassises
--
-- MIB groups. Note that the ones that are commented out are now defined in
-- separate MIB files. These are kept as placeholders here.
--
rcSystem OBJECT IDENTIFIER ::= { rcMgmt 1 }
rcTftp OBJECT IDENTIFIER ::= { rcMgmt 2 }
rcVlan OBJECT IDENTIFIER ::= { rcMgmt 3 }
rcChassis OBJECT IDENTIFIER ::= { rcMgmt 4 }
rcMirror OBJECT IDENTIFIER ::= { rcMgmt 5 }
rcDipSwitch OBJECT IDENTIFIER ::= { rcMgmt 6 }
rcTblSize OBJECT IDENTIFIER ::= { rcMgmt 7 }
rcIp OBJECT IDENTIFIER ::= { rcMgmt 8 }
rcArp OBJECT IDENTIFIER ::= { rcMgmt 9 }
rcRip OBJECT IDENTIFIER ::= { rcMgmt 10 }
rcTest OBJECT IDENTIFIER ::= { rcMgmt 11 }
rcStat OBJECT IDENTIFIER ::= { rcMgmt 12 }
rcStg OBJECT IDENTIFIER ::= { rcMgmt 13 }
rcBridge OBJECT IDENTIFIER ::= { rcMgmt 14 }
rcBoot OBJECT IDENTIFIER ::= { rcMgmt 15 }
rcDevice OBJECT IDENTIFIER ::= { rcMgmt 16 }
rcMlt OBJECT IDENTIFIER ::= { rcMgmt 17 }
rcWeb OBJECT IDENTIFIER ::= { rcMgmt 18 }
rcCli OBJECT IDENTIFIER ::= { rcMgmt 19 }
rcError OBJECT IDENTIFIER ::= { rcMgmt 20 }
rcTraps OBJECT IDENTIFIER ::= { rcMgmt 21 }
rcSyslog OBJECT IDENTIFIER ::= { rcMgmt 22 }
rcDiag OBJECT IDENTIFIER ::= { rcMgmt 23 }
rcIpx OBJECT IDENTIFIER ::= { rcMgmt 24 }
rcPos OBJECT IDENTIFIER ::= { rcMgmt 26 }
rcLinkFlapDetect OBJECT IDENTIFIER ::= { rcMgmt 27 }
rcV1Traps OBJECT IDENTIFIER ::= { rcMgmt 28 }
rcRadius OBJECT IDENTIFIER ::= { rcMgmt 29 }
rcIgmp OBJECT IDENTIFIER ::= { rcMgmt 30 }
rcUserSetTime OBJECT IDENTIFIER ::= { rcMgmt 31 }
rcL2Redundancy OBJECT IDENTIFIER ::= { rcMgmt 32 }
rcNtp OBJECT IDENTIFIER ::= { rcMgmt 33 }
rcSsh OBJECT IDENTIFIER ::= { rcMgmt 34 }
rcSvlan OBJECT IDENTIFIER ::= { rcMgmt 35 }
rcOpm OBJECT IDENTIFIER ::= { rcMgmt 36 }
rcVpn OBJECT IDENTIFIER ::= { rcMgmt 37 }
rcOeAdm OBJECT IDENTIFIER ::= { rcMgmt 38 }
rcTlsVpn OBJECT IDENTIFIER ::= { rcMgmt 39 }
rcTls OBJECT IDENTIFIER ::= { rcMgmt 40 }
rcCos OBJECT IDENTIFIER ::= { rcMgmt 41 }
rcBanRing OBJECT IDENTIFIER ::= { rcMgmt 42 }
rcTengEnet OBJECT IDENTIFIER ::= { rcMgmt 50 }
rcRec OBJECT IDENTIFIER ::= { rcMgmt 51 }
rcTdc OBJECT IDENTIFIER ::= { rcMgmt 52 }
rcLacp OBJECT IDENTIFIER ::= { rcMgmt 53 }
rcQos OBJECT IDENTIFIER ::= { rcMgmt 54 }
rcFilter OBJECT IDENTIFIER ::= { rcMgmt 55 }
rcLicense OBJECT IDENTIFIER ::= { rcMgmt 56 }
rcEap OBJECT IDENTIFIER ::= { rcMgmt 57 }
rcMcast OBJECT IDENTIFIER ::= { rcMgmt 58 }
rcOspf OBJECT IDENTIFIER ::= { rcMgmt 59 }
rcFdb OBJECT IDENTIFIER ::= { rcMgmt 60 }
rcIgap OBJECT IDENTIFIER ::= { rcMgmt 61 }
rcIpv6 OBJECT IDENTIFIER ::= { rcMgmt 62 }
rcIsis OBJECT IDENTIFIER ::= { rcMgmt 63 }
rcSlpp OBJECT IDENTIFIER ::= { rcMgmt 64 }
rcTacacs OBJECT IDENTIFIER ::= { rcMgmt 65 }
rcIpfix OBJECT IDENTIFIER ::= { rcMgmt 66 }
rcOspfv3 OBJECT IDENTIFIER ::= { rcMgmt 67 }
rcFlowClassifier OBJECT IDENTIFIER ::= { rcMgmt 68 }
rc2k OBJECT IDENTIFIER ::= { rcMgmt 100 }
rcOm8k OBJECT IDENTIFIER ::= { rcMgmt 200 }
cobra OBJECT IDENTIFIER ::= { rcMgmt 201 }
rcPowerRanger OBJECT IDENTIFIER ::= { rcMgmt 202 }
-- LOGICAL (System) Elements
rcSysIpAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This entity's IP address."
::= { rcSystem 1 }
rcSysNetMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This entity's subnet mask."
::= { rcSystem 2 }
rcSysBroadcast OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This entity's broadcast address."
::= { rcSystem 3 }
-- Community Strings
rcSysCommReadWriteAll OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "When an SNMP message is received by this entity, the
community string in the message is compared with this
string first. If it matches, read-write access is
granted to all items in the MIB. If it doesn't
match, the rcSysCommReadWrite string is compared next."
::= { rcSystem 4 }
rcSysCommReadWrite OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "When an SNMP message is received by this entity, the
community string in the message is compared with this
string second. If it matches, read-write access is
granted to all items in the MIB except community
strings. (Community strings appear empty when read
and return a no such name error when an attempt is
made to write them.) If it doesn't match, the
rcSysCommReadWriteLayer3 string is compared next."
::= { rcSystem 5 }
rcSysCommReadOnly OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "When an SNMP message is received by this entity, the
community string in the message is compared with this
string third. If it matches, read-only access is
granted to all items in the MIB except community
strings. (Community strings appear empty when read.)
If it doesn't match, no access is granted, no
response is sent back to the SNMP requester, and
SNMP traps are sent to the SNMP trap receiver(s) if
configured."
::= { rcSystem 6 }
-- Other
rcSysVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..80))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Software version running on device"
::= { rcSystem 7 }
rcSysAction OBJECT-TYPE
SYNTAX INTEGER {
none(1), -- none of the following
hardReset(2), -- power on tests
softReset(3), -- reset w/o power on tests
saveToNVRAM(4), -- save current config to NVRAM
resetCounters(5), -- reset all statistic counters
saveToStandbyNVRAM(6), -- save config to slave NVRAM
cpuSwitchOver(7), -- CPU board switch-over
checkSwInFlash(8),
checkSwInPcmcia(9),
resetConsole(10),
resetModem(11),
flushIpRouteTbl(12),
saveRuntimeConfig(13), -- 8k only
saveRuntimeConfigToSlave(14), -- 8k only
saveBootConfig(15), -- 8k only
saveSlaveBootConfig(16), -- 8k only
resetIstStatCounters(17),
-- being used in rel2.2(18)
-- being used in rel2.2(19)
-- reserve(20)
-- reserve(21)
resetEsmPortStats(22)
}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION "Initiate a system action."
DEFVAL { none }
::= { rcSystem 8 }
rcSysResult OBJECT-TYPE
SYNTAX INTEGER {
none(1), -- none of the following
inProgress(2), -- in progress
success(3), -- success
fail(4), -- failure
flashReadFailed(5), -- could not read from flash
pcmciaReadFailed(6), -- could not read from pcmcia
crcCheckFailed(7),
noStandbyCpu(8)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Result from the last system action."
DEFVAL { none }
::= { rcSystem 9 }
rcSysLastChange OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Last management initiated configuration
change since sysUpTime."
::= { rcSystem 10 }
rcSysLastVlanChange OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Last management initiated VLAN configuration
change since sysUpTime."
::= { rcSystem 11 }
rcSysLastStatisticsReset OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Last management initiated statistics reset
since sysUpTime."
::= { rcSystem 12 }
-- Global Statistics
rcSysBufferUtil OBJECT-TYPE
SYNTAX INTEGER (0..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Buffer utilization as a percentage of the
total amount of buffer space in the system.
A high value indicates congestion."
::= { rcSystem 13 }
rcSysBufferUtilPeak OBJECT-TYPE
SYNTAX INTEGER (0..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The largest buffer utilization since sysUpTime"
::= { rcSystem 14 }
rcSysBufferUtilPeakTime OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Timestamp for rcSysPeakBandwidth"
::= { rcSystem 15 }
rcSysNVRamSize OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Total Non-volatile RAM in Kbytes"
::= { rcSystem 16 }
rcSysNVRamUsed OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Non-volatile RAM in use in Kbytes"
::= { rcSystem 17 }
rcSysLastSaveToNVRam OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION "SysUpTime of the last time when NVRAM was
written to. This could be a save of the system
configuration or via a file transfer of a
configuration file."
::= { rcSystem 18 }
rcSysLastSaveToStandbyNVRam OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION "SysUpTime of the last time when the standby NVRAM
(on the back-up CPU board) was written to."
::= { rcSystem 19 }
rcSysCpuUtil OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Percentage of CPU utilization"
::= { rcSystem 20 }
rcSysSwitchFabricUtil OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Percentage of Switching Fabric utilization"
::= { rcSystem 21 }
rcSysRmonMemSize OBJECT-TYPE
SYNTAX INTEGER (250000..4000000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Amount of RAM in bytes to allocate for RMON
to use when rcSysRmonEnable is TRUE."
::= { rcSystem 22 }
rcSysRmonEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Control whether the RMON feature should be
enabled.
To enable the RMON feature, set this variable to
true. The RMON agent in the device will get
started immediately if the amount of memory
specified by rcSysRmonMemSize is currently
available in the device.
To disable the RMON feature, set this variable to
false, save the new setting to NVRAM, and reboot
the device. After the device is rebooted the
RMON agent will not be operational."
::= { rcSystem 23 }
rcSysRmonSaveConfig OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION "Control whether RMON configuration information
should be saved to NVRAM so RMON settings can
be automatically reinstalled after a system
reboot.
Setting rcSysRmonSaveConfig to true does not
immediately save the configuration information.
The save happens when the rcSysAction variable
is set to 'saveToNVRAM(4)'.
This option is only meaningful when the
rcSysRmonEnable variable is set to true."
::= { rcSystem 24 }
rcSysRmonTrapOption OBJECT-TYPE
SYNTAX INTEGER {
toOwner(1),
toAll(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to indicate whether RMON traps should be
sent to only the owner of the RMON alarm (i.e.,
the manager that created the alarm entry) or
all trap recipients in the system trap receiver
table."
DEFVAL { toOwner }
::= { rcSystem 25 }
rcSysSupportRouting OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Used to indicate whether routing is supported
in this product."
::= { rcSystem 26 }
rcSysSupportWebServer OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Used to indicate whether WebServer is supported
in this product."
::= { rcSystem 27 }
rcSysLastIpAddrChange OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Last management initiated IP address change
since sysUpTime. Any addition or deletion of
an IP address to a single routable port or
a VLAN is time-stamped by this variable."
::= { rcSystem 28 }
rcSysCommReadWriteLayer3 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "When an SNMP message is received by this entity, the
community string in the message is compared with this
string third. If it matches, read-write access is
granted to all Layer-3 items in the MIB except community
strings. (Community strings appear empty when read
and return a no such name error when an attempt is
made to write them.) If it doesn't match, the
rcSysCommReadWriteLayer2 string is compared next."
::= { rcSystem 29 }
rcSysCommReadWriteLayer2 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "When an SNMP message is received by this entity, the
community string in the message is compared with this
string fourth. If it matches, read-write access is
granted to all Layer-2 items in the MIB except community
strings. (Community strings appear empty when read
and return a no such name error when an attempt is
made to write them.) If it doesn't match, the
rcSysCommReadOnly string is compared next."
::= { rcSystem 30 }
rcSysAccessPolicyEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to configure the system access policy feature.
if 'true', the rcSysAccessPolicyTable is examined to
determine which packets should be allowed or denied
access to this device."
DEFVAL { false }
::= { rcSystem 31 }
rcSysDefaultRuntimeConfigFileName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "default config."
::= { rcSystem 32 }
rcSysDefaultBootConfigFileName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "default boot config."
::= { rcSystem 33 }
rcSysConfigFileName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "File name used in conjunction with rcSysAction.
If rcSysAction is set to 'saveRuntimeConfig' or
'saveRuntimeConfigToSlave' then this file name
will be used instead of the file name specified
in rcSysDefaultRuntimeConfigFileName.
If rcSysAction is set to 'saveBootConfig' or
'saveBootConfigToSlave' then this file name will
be used insteaad of the file name specified in
rcSysDefaultBootConfigFileName.
If the file name is blank (i.e., nothing is
entered) then the default file name will be
used."
::= { rcSystem 34 }
rcSysLastRunTimeConfigSave OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION "SysUpTime of the last time when the run time
configuration was written to."
::= { rcSystem 35 }
rcSysLastRunTimeConfigSaveToSlave OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION "SysUpTime of the last time when the run time
configuration was written to slave NVRAM."
::= { rcSystem 36 }
rcSysLastBootConfigSave OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION "SysUpTime of the last time when the boot
configuration was written to."
::= { rcSystem 37 }
rcSysLastBootConfigSaveOnSlave OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION "SysUpTime of the last time when the boot
configuration was written on the slave NVRAM."
::= { rcSystem 38 }
rcSysRmonUtilizationMethod OBJECT-TYPE --excluded
SYNTAX INTEGER {
halfDuplex(1),
fullDuplex(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to control whether RMON should use a half-duplex
or full-duplex formula to calculate port utilization.
When set to 'halfDuplex', RMON will use InOctets and
the port's speed to calculate port utilization (this
is the standard RMON rfc1271 convention).
When set to 'fullDuplex', RMON will use InOctets and
OutOctets and 2X the port's speed to calculate port
utilization. Furthermore, if this variable is set to
'fullDuplex', but the port is operating in a
half-duplex mode, the calculation defaults back to
the rfc1271 convention."
DEFVAL { halfDuplex }
::= { rcSystem 39 }
rcSysCommReadWriteLayer1 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "read-write L1 access"
::= { rcSystem 40 }
rcSysOtherBufferUtil OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "bw currently consumed"
::= { rcSystem 41 }
rcSysOtherBufferUtilPeak OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "peak bw since reset"
::= { rcSystem 42 }
rcSysOtherBufferUtilPeakTime OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION "timestamp for rcSysPeakBw"
::= { rcSystem 43 }
rcSysOtherCpuUtil OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "% cpu utilization"
::= { rcSystem 44 }
rcSysOtherSwitchFabricUtil OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "% switch fabric util"
::= { rcSystem 45 }
rcSysDramSize OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Dram size in mega-bytes"
::= { rcSystem 46 }
rcSysDramUsed OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Dram used in percentage"
::= { rcSystem 47 }
rcSysDramFree OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Dram free size in kilo-bytes"
::= { rcSystem 48 }
rcSysDramMaxBlockFree OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Dram max block free size in kilo-bytes"
::= { rcSystem 49 }
rcSysVirtualIpAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Virtual IP is an IP address that owned and
advertised only by the master CPU. So whichever
CPU is master registers this IP address. Unlike the
management IP address, this address goes in the
switch config file and not the boot config"
::= { rcSystem 51 }
rcSysVirtualNetMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Net mask of the management virtual Ip address"
::= { rcSystem 52 }
rcSysReadWriteLevel OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The status of the read/write level"
::= { rcSystem 53 }
rcSysMTUSize OBJECT-TYPE
SYNTAX INTEGER {
mtu1950(1),
mtu9600(2),
mtu1522(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "This is the maximum transmission size of frames that all
the ports on the chassis support."
DEFVAL { mtu1950 }
::= { rcSystem 55 }
rcSysClockSyncTime OBJECT-TYPE
SYNTAX INTEGER (15..3600)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Time interval at which RTC and system clocks are
synchronized."
DEFVAL { 60 }
::= { rcSystem 56 }
rcSysForceTrapSender OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "This is a flag that if user wants to configured
CLIP (Circuit Less IP) as trap originator."
::= { rcSystem 57 }
rcSysMrouteStrLimit OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "enable or disable mroute stream limit in system."
DEFVAL { false }
::= { rcSystem 58 }
-- Trap Receiver Table
rcSysTrapRecvTable OBJECT-TYPE
SYNTAX SEQUENCE OF RcSysTrapRecvEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION "The trap receiver table (0 to 25 entries). This
table lists the addresses of Network Management
Stations that should receive trap messages from
this entity when an exception condition occurs."
::= { rcSystem 60 }
rcSysTrapRecvEntry OBJECT-TYPE
SYNTAX RcSysTrapRecvEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION "A trap receiver table entry."
INDEX { rcSysTrapRecvAddress }
::= { rcSysTrapRecvTable 1 }
RcSysTrapRecvEntry ::=
SEQUENCE {
rcSysTrapRecvAddress IpAddress,
rcSysTrapRecvVersion INTEGER,
rcSysTrapRecvCommunity DisplayString,
rcSysTrapRecvSrcAddress IpAddress,
rcSysTrapRecvRowStatus RowStatus
}
rcSysTrapRecvAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "IP address for trap receiver."
::= { rcSysTrapRecvEntry 1 }
rcSysTrapRecvVersion OBJECT-TYPE
SYNTAX INTEGER {
v1(1),
v2c(2)
}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION "The version of trap receiver."
DEFVAL { v1 }
::= { rcSysTrapRecvEntry 2 }
rcSysTrapRecvCommunity OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION "Community string used for trap messages to this
trap receiver."
::= { rcSysTrapRecvEntry 3 }
rcSysTrapRecvSrcAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION "Source IP address to use when sending traps.
This IP address will be inserted into the
source IP address field in the UDP trap packet."
::= { rcSysTrapRecvEntry 4 }
rcSysTrapRecvRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION "Used to create/delete entries"
::= { rcSysTrapRecvEntry 5 }
-- Access Policy Table
rcSysAccessPolicyTable OBJECT-TYPE
SYNTAX SEQUENCE OF RcSysAccesspolicyEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Management access policy table. This table is
used to permit or deny access to this device via
the specified source Id."
::= { rcSystem 61 }
rcSysAccessPolicyEntry OBJECT-TYPE
SYNTAX RcSysAccesspolicyEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An access policy table entry."
INDEX { rcSysAccessPolicyId }
::= { rcSysAccessPolicyTable 1 }
RcSysAccesspolicyEntry ::=
SEQUENCE {
rcSysAccessPolicyId INTEGER,
rcSysAccessPolicyName DisplayString,
rcSysAccessPolicyPolicyEnable TruthValue,
rcSysAccessPolicyMode INTEGER,
rcSysAccessPolicyService INTEGER,
rcSysAccessPolicyPrecedence INTEGER,
rcSysAccessPolicyNetAddr IpAddress,
rcSysAccessPolicyNetMask IpAddress,
rcSysAccessPolicyTrustedHostAddr IpAddress,
rcSysAccessPolicyTrustedHostUserName DisplayString,
rcSysAccessPolicyAccessLevel INTEGER,
rcSysAccessPolicyLog TruthValue,
rcSysAccessPolicyUsage Counter32,
rcSysAccessPolicyRowStatus RowStatus,
rcSysAccessPolicyAccessStrict TruthValue,
rcSysAccessPolicyNetInetAddrType InetAddressType,
rcSysAccessPolicyNetInetAddress InetAddress,
rcSysAccessPolicyNetInetAddrPrefixLen InetAddressPrefixLength,
rcSysAccessPolicyTrustedHostInetAddress InetAddress
}
rcSysAccessPolicyId OBJECT-TYPE
SYNTAX INTEGER (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Policy Id."
::= { rcSysAccessPolicyEntry 1 }
rcSysAccessPolicyName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..15))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Name of this policy."
::= { rcSysAccessPolicyEntry 2 }
rcSysAccessPolicyPolicyEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Indicate whether this policy is currently
active."
DEFVAL { true }
::= { rcSysAccessPolicyEntry 3 }
rcSysAccessPolicyMode OBJECT-TYPE
SYNTAX INTEGER {
allow(1),
deny(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to indicate whether a packet having a
source IP address that matches this entry
should be permitted to enter the device or
denied access."
DEFVAL { allow }
::= { rcSysAccessPolicyEntry 4 }
rcSysAccessPolicyService OBJECT-TYPE
SYNTAX INTEGER (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Is represented as bitset to indicate which protocol
this entry should be applied to.
Value is one of multiple(logical 'OR')
of the following values:
telnet(1): enables telnet service
snmp(2): enables snmp service
tftp(4): enables tftp service
ftp(8): enables ftp service
http(16): enables http service
rlogin(32): enables rlogin service
ssh(64): enables ssh service
snmp-v3(128): enables snmp service for v3 groups."
::= { rcSysAccessPolicyEntry 5 }
rcSysAccessPolicyPrecedence OBJECT-TYPE
SYNTAX INTEGER (1..128)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to indicate the precedence of this policy.
The Lower the number the higher the precedence."
DEFVAL { 10 }
::= { rcSysAccessPolicyEntry 6 }
rcSysAccessPolicyNetAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Source network IP address."
::= { rcSysAccessPolicyEntry 7 }
rcSysAccessPolicyNetMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Source network mask."
::= { rcSysAccessPolicyEntry 8 }
rcSysAccessPolicyTrustedHostAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Trusted IP address of host performing a rlogin
into the device."
::= { rcSysAccessPolicyEntry 9 }
rcSysAccessPolicyTrustedHostUserName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..30))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "User name on the trusted host performing a rlogin
into the device."
::= { rcSysAccessPolicyEntry 10 }
rcSysAccessPolicyAccessLevel OBJECT-TYPE
SYNTAX INTEGER {
readOnly(1),
readWrite(2),
readWriteAll(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Access level of trusted host."
DEFVAL { readOnly }
::= { rcSysAccessPolicyEntry 11 }
rcSysAccessPolicyLog OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to indicate whether logging should be
performed if this policy was applied."
DEFVAL { false }
::= { rcSysAccessPolicyEntry 12 }
rcSysAccessPolicyUsage OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Usage Counter"
::= { rcSysAccessPolicyEntry 13 }
rcSysAccessPolicyRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to create/delete an entry"
::= { rcSysAccessPolicyEntry 14 }
rcSysAccessPolicyAccessStrict OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to restrict the access level specified in
the system access policy table to exactly the
same access level as specified by user. If TRUE
then only the access level in the policy table
is allowed access. If FALSE, then the default
behavior is to assume the access level specified
in policy table as the floor."
DEFVAL { false }
::= { rcSysAccessPolicyEntry 15 }
rcSysAccessPolicyNetInetAddrType OBJECT-TYPE
SYNTAX InetAddressType
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Source network Inet Address Type."
::= { rcSysAccessPolicyEntry 16 }
rcSysAccessPolicyNetInetAddress OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Source network Inet Address (prefix/network)."
::= { rcSysAccessPolicyEntry 17 }
rcSysAccessPolicyNetInetAddrPrefixLen OBJECT-TYPE
SYNTAX InetAddressPrefixLength
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Source network Inet Address Prefix-Length/Mask."
::= { rcSysAccessPolicyEntry 18 }
rcSysAccessPolicyTrustedHostInetAddress OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Trusted Inet address of host performing a rlogin
into the device."
::= { rcSysAccessPolicyEntry 19 }
-- Trap Sender Address Table
rcSysTrapSenderTable OBJECT-TYPE
SYNTAX SEQUENCE OF RcSysTrapSenderEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The trap sender table (0 to 25 entries). This
table lists the addresses of Network Management
Stations and the Source Address that should receive
trap messages from this entity when an exception
condition occurs."
::= { rcSystem 62 }
rcSysTrapSenderEntry OBJECT-TYPE
SYNTAX RcSysTrapSenderEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A trap sender table entry."
INDEX { rcSysTrapSenderRecvAddress }
::= { rcSysTrapSenderTable 1 }
RcSysTrapSenderEntry ::=
SEQUENCE {
rcSysTrapSenderRecvAddress IpAddress,
rcSysTrapSenderSrcAddress IpAddress
}
rcSysTrapSenderRecvAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION "IP address for trap receiver."
::= { rcSysTrapSenderEntry 1 }
rcSysTrapSenderSrcAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION "IP address for trap sender."
::= { rcSysTrapSenderEntry 2 }
-- DNS Server List Mibs
rcSysDnsServerListTableSize OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Used to indicate the number of entries in the
table."
::= { rcSystem 63 }
rcSysDnsServerListTable OBJECT-TYPE
SYNTAX SEQUENCE OF RcSysDnsServerListEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "DNS serever list table used to store the
details of the DNS server configured."
::= { rcSystem 64 }
rcSysDnsServerListEntry OBJECT-TYPE
SYNTAX RcSysDnsServerListEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "table entry."
INDEX {rcSysDnsServerListType}
::= { rcSysDnsServerListTable 1 }
RcSysDnsServerListEntry ::=
SEQUENCE {
rcSysDnsServerListType INTEGER,
rcSysDnsServerListIp IpAddress, -- deprecated
rcSysDnsServerListStatus INTEGER,
rcSysDnsServerListRequestCount Counter32,
rcSysDnsServerListSuccessCount Counter32,
rcSysDnsServerListRowStatus RowStatus,
rcSysDnsServerListAddressType InetAddressType,
rcSysDnsServerListAddress InetAddress
}
rcSysDnsServerListType OBJECT-TYPE
SYNTAX INTEGER {
primary(0),
secondary(1),
tertiary(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Type of the DNS server"
::= { rcSysDnsServerListEntry 1 }
rcSysDnsServerListIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION "IP address of the DNS server"
::= { rcSysDnsServerListEntry 2 }
rcSysDnsServerListStatus OBJECT-TYPE
SYNTAX INTEGER {
active(0),
in-active(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Status of DNS server"
::= { rcSysDnsServerListEntry 3 }
rcSysDnsServerListRequestCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Number of request send to this server"
::= { rcSysDnsServerListEntry 4 }
rcSysDnsServerListSuccessCount OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Number of request send to this server which
are successful"
::= { rcSysDnsServerListEntry 5 }
rcSysDnsServerListRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to create/delete DNS server entries
in rcSysDnsServerListTable."
::= { rcSysDnsServerListEntry 6 }
rcSysDnsServerListAddressType OBJECT-TYPE
SYNTAX InetAddressType
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The type of ip address configured by the DNS server"
::= { rcSysDnsServerListEntry 7 }
rcSysDnsServerListAddress OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The ip address configured by the DNS server"
::= { rcSysDnsServerListEntry 8 }
-- DNS Host Table
rcSysDnsHostTable OBJECT-TYPE
SYNTAX SEQUENCE OF RcSysDnsHostEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "DNS Host table."
::= { rcSystem 65 }
rcSysDnsHostEntry OBJECT-TYPE
SYNTAX RcSysDnsHostEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "table entry."
INDEX { rcSysDnsHostData }
::= { rcSysDnsHostTable 1 }
RcSysDnsHostEntry ::=
SEQUENCE {
rcSysDnsHostData OCTET STRING,
rcSysDnsHostName OCTET STRING,
rcSysDnsHostIpAddress IpAddress, -- deprecated
rcSysDnsHostSource OCTET STRING,
rcSysDnsHostAddressType InetAddressType,
rcSysDnsHostAddress InetAddress
}
rcSysDnsHostData OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..256))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Host Name or Host IP Address."
::= { rcSysDnsHostEntry 1 }
rcSysDnsHostName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..256))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Host Name."
::= { rcSysDnsHostEntry 2 }
rcSysDnsHostIpAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "Host IP Address."
::= { rcSysDnsHostEntry 3 }
rcSysDnsHostSource OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..256))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "DNS Server IP or /etc/host file."
::= { rcSysDnsHostEntry 4 }
rcSysDnsHostAddressType OBJECT-TYPE
SYNTAX InetAddressType
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The type of ip address for the DNS host"
::= { rcSysDnsHostEntry 5 }
rcSysDnsHostAddress OBJECT-TYPE
SYNTAX InetAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The ip address of the DNS host"
::= { rcSysDnsHostEntry 6 }
rcSysMsgLogFrequency OBJECT-TYPE
SYNTAX INTEGER (2..500)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Used to specify the maximum frequency/count
of the occurence of the Log Message."
::= { rcSystem 66 }
rcSysMsgLogText OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..3))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A textual string containing the first four
characters of the Log Message."
::= { rcSystem 67 }
rcSysForceIpHdrSender OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Flag to decide if IP header source address will
be matched with SNMP header sender networks."
DEFVAL { false }
::= { rcSystem 68 }
rcSysVlanMaxId OBJECT-TYPE
SYNTAX INTEGER {
maxId2000(2000),
maxId4000(4000)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The maximum vlan Id that supported"
DEFVAL { maxId2000 }
::= { rcSystem 69 }
rcSysDnsDomainName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Default domain used for querying the DNS Server."
::= { rcSystem 70 }
rcSysDnsServerListIpAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION "DNS server's IP address "
::= { rcSystem 71 }
rcSysDnsRequestType OBJECT-TYPE
SYNTAX INTEGER {
request (0),
response (1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "DNS Type: Whether it was Dns Request or a Response"
::= { rcSystem 72 }
rcSysSpanningTreeOperMode OBJECT-TYPE
SYNTAX INTEGER {
nortelStpg(1),
pvst(2),
rstp(3),
mstp(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object indicates the current spanning-tree mode of the system. .
The meaning of specific values is:
nortelStpg(1) .. The older proprietary mode which supports multiple spanning tree groups.
pvst(2) ........ Emulation of C***O spanning tree mode
rstp(3) ........ IEEE 802.1w mode
mstp(4) ........ IEEE 802.1s mode ."
DEFVAL { nortelStpg }
::= { rcSystem 73}
rcSysSpanningTreeAdminMode OBJECT-TYPE
SYNTAX INTEGER {
nortelStpg(1),
pvst(2),
rstp(3),
mstp(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "This object indicates the desired spanning-tree mode of the system.
The meaning of specific values is:
nortelStpg(1) .. The older proprietary mode which supports multiple spanning tree groups.
pvst(2) ........ Emulation of C***O spanning tree mode
rstp(3) ........ IEEE 802.1w mode
mstp(4) ........ IEEE 802.1s mode
Note that depending on the current value of rcSysSpanningTreeOperMode and
the value to which this object is set, the operational mode may be immediately changed,
or the change may not take effect until the next system reboot."
DEFVAL { nortelStpg }
::= { rcSystem 74}
rcSysAutoRecoverDelay OBJECT-TYPE
SYNTAX INTEGER (5..3600)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Time interval in seconds after which auto-recovery
runs on ports to clear action taken by cp-limit,
link flap or loop detect"
::= { rcSystem 75 }
rcSysMacFlapLimitTime OBJECT-TYPE
SYNTAX INTEGER (10..5000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Time limit in milliseconds for MAC flapping for
loop-detect feature"
::= { rcSystem 76 }
rcSysMacFlapLimitCount OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Number of times mac flapping can happen for loop-detect
feature"
::= { rcSystem 77 }
rcSysExtCplimitEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "enable or disable extended CP-LIMIT in system."
DEFVAL { false }
::= { rcSystem 78 }
rcSysExtCplimitMinCongTime OBJECT-TYPE
SYNTAX INTEGER (100..6000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Minimum time for which System octapid should be
congested to trigger congestion algorithm for extended
CP-LIMIT in mSecs"
DEFVAL { 3000 }
::= { rcSystem 79 }
rcSysExtCplimitMaxPorts OBJECT-TYPE
SYNTAX INTEGER (0..512)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Maximum number of ports which need to be monitored
for congestion in Extended CP-LIMIT"
DEFVAL { 0 }
::= { rcSystem 80 }
rcSysExtCplimitPortCongTime OBJECT-TYPE
SYNTAX INTEGER (1..600)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Minimum time for which ingress traffic utilization rate
of a monitored port should stay more than the allowed limits
in order to disable the port for extended CP-LIMIT in Secs"
DEFVAL { 300 }
::= { rcSystem 81 }
rcSysExtCplimitTrapLevel OBJECT-TYPE
SYNTAX INTEGER {
none(1),
normal(2),
verbose(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Indicates the trap level for extended CP-LIMIT"
DEFVAL { none }
::= { rcSystem 82 }
rcSysExtCplimitSysOctapidCongested OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates whether system octapid congestion detected for
extended cp-limit"
DEFVAL { false }
::= {rcSystem 83 }
rcSysExtCplimitPortsMonitored OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates whether ports has been shutdown due to extended
cp-limit"
DEFVAL { false }
::= {rcSystem 84 }
rcSysExtCplimitPortsShutDown OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates whether ports has been shutdown due to
extended Cp-limit"
DEFVAL { false }
::= {rcSystem 85 }
rcSysActionL1 OBJECT-TYPE
SYNTAX INTEGER {
none(1),
resetCounters(2), -- reset all statistic counters
saveToNVRAM(3),
saveToStandbyNVRAM(4), -- save config to slave NVRAM
checkSwInFlash(5),
checkSwInPcmcia(6),
saveRuntimeConfig(7), -- 8k only
saveRuntimeConfigToSlave(8), -- 8k only
saveBootConfig(9), -- 8k only
saveSlaveBootConfig(10) -- 8k only
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Initiate a system action for layer1 user"
DEFVAL { none }
::= { rcSystem 86 }
rcSysActionL2 OBJECT-TYPE
SYNTAX INTEGER {
none(1),
resetIstStatCounters(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Initiate a system action for layer2 user"
DEFVAL { none }
::= { rcSystem 87 }
rcSysActionL3 OBJECT-TYPE
SYNTAX INTEGER {
none(1),
flushIpRouteTbl(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Initiate a system action for layer2 user"
DEFVAL { none }
::= { rcSystem 88 }
rcSysActionRwa OBJECT-TYPE
SYNTAX INTEGER {
none(1), -- none of the following
hardReset(2), -- power on tests
softReset(3), -- reset w/o power on tests
cpuSwitchOver(4), -- CPU board switch-over
resetConsole(5),
resetModem(6)
-- being used in rel2.2(7)
-- being used in rel2.2(8)
-- reserve(9)
-- reserve(10)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Initiate a system action."
DEFVAL { none }
::= { rcSystem 89 }
rcSysPowerUsage OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The current power usage for the whole chassis."
::= { rcSystem 90 }
rcSysPowerAvailable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The current power available for the whole chassis."
::= { rcSystem 91 }
rcSysBpduStartMacAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Starting Multicast MAC address for BPDUs"
::= { rcSystem 92 }
rcSysBpduMacAddressMask OBJECT-TYPE
SYNTAX INTEGER (1..48)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "BPDU MAC address Mask"
::= { rcSystem 93 }
rcSysFrcMsgControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF RcSysFrcMsgControlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Management Force-msg Control table. This table is used to
specify the pattern for Force-msg Control"
::= { rcSystem 94 }
rcSysFrcMsgControlEntry OBJECT-TYPE
SYNTAX RcSysFrcMsgControlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A Force-msg Control table entry."
INDEX { rcSysFrcMsgControlPatternId }
::= { rcSysFrcMsgControlTable 1 }
RcSysFrcMsgControlEntry ::=
SEQUENCE {
rcSysFrcMsgControlPatternId Integer32,
rcSysFrcMsgControlPattern DisplayString,
rcSysFrcMsgControlRowStatus RowStatus
}
rcSysFrcMsgControlPatternId OBJECT-TYPE
SYNTAX Integer32 (1..32)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Pattern Id."
::= { rcSysFrcMsgControlEntry 1 }
rcSysFrcMsgControlPattern OBJECT-TYPE
SYNTAX DisplayString (SIZE (4))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Pattern for filtering the force-msg for msg control"
::= { rcSysFrcMsgControlEntry 2 }
rcSysFrcMsgControlRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to create/delete an entry"
::= { rcSysFrcMsgControlEntry 3 }
rcSysAccPolSnmpGrpTable OBJECT-TYPE
SYNTAX SEQUENCE OF RcSysAccPolSnmpGrpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "SNMP group list for access policy"
::= { rcSystem 95 }
rcSysAccPolSnmpGrpEntry OBJECT-TYPE
SYNTAX RcSysAccPolSnmpGrpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The table entry which covers the groups under snmp service."
INDEX { rcSysAccessPolicyId, rcSysAccPolSnmpGrpName, rcSysAccPolSnmpGrpModel}
::= { rcSysAccPolSnmpGrpTable 1 }
RcSysAccPolSnmpGrpEntry ::=
SEQUENCE {
rcSysAccPolSnmpGrpName SnmpAdminString,
rcSysAccPolSnmpGrpModel SnmpSecurityModel,
rcSysAccPolSnmpGrpRowStatus RowStatus
}
rcSysAccPolSnmpGrpName OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE(1..32))
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The snmp-v3 group name"
::= { rcSysAccPolSnmpGrpEntry 1 }
rcSysAccPolSnmpGrpModel OBJECT-TYPE
SYNTAX SnmpSecurityModel
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The snmp model"
::= { rcSysAccPolSnmpGrpEntry 2 }
rcSysAccPolSnmpGrpRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Row status"
::= { rcSysAccPolSnmpGrpEntry 3 }
rcSysVirtualIpv6Addr OBJECT-TYPE
SYNTAX Ipv6Address
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The virtual ipv6 address that is owned, advertised, and registered by the master CPU only. Unlike the net management IP address this address is configured in the switch config file as opposed to the boot config."
::= { rcSystem 96 }
rcSysVirtualIpv6PrefixLength OBJECT-TYPE
SYNTAX INTEGER (0..128)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The length of the virtual ipv6 addr prefix (in bits)."
::= { rcSystem 97 }
-- TFTP Upload/Download
rcTftpHost OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Name of source/destination host for the TFTP
transfer."
::= { rcTftp 1 }
rcTftpFile OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Name of file for the TFTP transfer."
::= { rcTftp 2 }
rcTftpAction OBJECT-TYPE
SYNTAX INTEGER {
none(1), -- none of the following
downloadConfig(2),
uploadConfig(3),
downloadSwToFlash(4),
downloadSwToPcmcia(5),
uploadSw(6),
downloadSwToDram(7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The action for the TFTP transfer."
DEFVAL { none }
::= { rcTftp 3 }
rcTftpResult OBJECT-TYPE
SYNTAX INTEGER {
none(1),
inProgress(2),
noResponse(3),
fileAccessError(4),
badFlash(5),
flashEraseFailed(6),
pcmciaEraseFailed(7),
success(8),
fail(9),
writeToNvramFailed(10),
flashWriteFailed(11),
pcmciaWriteFailed(12),
configFileTooBig(13),
imageFileTooBig(14),
noPcmciaDetect(15),
pcmciaNotSupported(16),
invalidFile(17),
noMemory(18),
xferError(19),
crcError(20),
readNvramFailed(21),
pcmciaWriteProtect(22)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Contains result of the last Tftp action request."
::= { rcTftp 4 }
-- PHYSICAL Elements
rcChasType OBJECT-TYPE
SYNTAX INTEGER {
unknown(1), -- unknown chassis
a1100(2), -- 3 slot chassis (1/2, 1/2, full)
a1250(6), -- 4 slot chassis (full, ... , full)
a1150(7), -- 3 slot chassis (1/2, 1/2, full)
a1200(8), -- 8 slot chassis (full, ... , full)
a1050(9), -- 2 slot chassis (seahawk)
a8006(280887558), -- 6 slot chassis (raptillion)
a8010(280887562), -- 10 slot chassis (raptillion)
a8010co(1623064842), -- 10 slot Central Office Chassis
a8003(280887555), -- 3 slot chassis (raptillion)
a1612G(1086197761), -- 1 slot 12 port cobra (0x40be1001)
a1624G(1086201857), -- 1 slot 24 port cobra (0x40be2001)
a1648T(1086210049), -- 1 slot 52 port cobra (0x40be4001)
a8306(1354629382), -- 6 slot 8300 POE chassis (0x50be0106)
a8310(1354629386) -- 10 slot 8300 POE chassis (0x50be010a)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Chassis Type"
::= { rcChassis 1 }
rcChasSerialNumber OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Unique serial number for this chassis."
::= { rcChassis 2 }
rcChasHardwareRevision OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Device hardware revision level"
::= { rcChassis 3 }
rcChasNumSlots OBJECT-TYPE
SYNTAX INTEGER (1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The number of slots in the chassis available for
plug-in cards."
::= { rcChassis 4 }
rcChasNumPorts OBJECT-TYPE
SYNTAX INTEGER (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The total number of ports currently installed in
the chassis."
::= { rcChassis 5 }
-- TBD FIXME : We need to get the final list from Hardware
rcChasTestResult OBJECT-TYPE
SYNTAX INTEGER {
other(1),
ok(2),
crceeprom(3),
timer(4),
procdram(5),
led(6),
formaccpuaccess(7),
asiccpuaccess(8),
memory(9),
loopback(10)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Chassis start-up diagnostic tests."
::= { rcChassis 6 }
rcChasFan OBJECT IDENTIFIER ::= { rcChassis 7 }
rcChasFanTable OBJECT-TYPE
SYNTAX SEQUENCE OF RcChasFanEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table contains information about Fans"
::= { rcChasFan 1 }
rcChasFanEntry OBJECT-TYPE
SYNTAX RcChasFanEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Contains information regarding a Fan Unit"
INDEX { rcChasFanId }
::= { rcChasFanTable 1 }
RcChasFanEntry ::=
SEQUENCE {
rcChasFanId INTEGER,
rcChasFanOperStatus INTEGER,
rcChasFanAmbientTemperature Gauge32
}
rcChasFanId OBJECT-TYPE
SYNTAX INTEGER(1..4)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The chassis fan Id."
::= { rcChasFanEntry 1 }
rcChasFanOperStatus OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
up(2),
down(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Actual status of the Fan:
- unknown(1) - status can not be determined.
- up(2) - present and supplying power.
- down(3) - present, but failure indicated."
::= { rcChasFanEntry 2 }
rcChasFanAmbientTemperature OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Used to indicate the temperature of the air
entering the fan."
::= { rcChasFanEntry 3 }
rcChasPowerSupply OBJECT IDENTIFIER ::= { rcChassis 8 }
rcChasPowerSupplyTable OBJECT-TYPE
SYNTAX SEQUENCE OF RcChasPowerSupplyEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table contains information about power
supplies."
::= { rcChasPowerSupply 1 }
rcChasPowerSupplyEntry OBJECT-TYPE
SYNTAX RcChasPowerSupplyEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Contains information regarding a power supply
unit."
INDEX { rcChasPowerSupplyId }
::= { rcChasPowerSupplyTable 1 }
RcChasPowerSupplyEntry ::=
SEQUENCE {
rcChasPowerSupplyId INTEGER,
rcChasPowerSupplyOperStatus INTEGER
}
rcChasPowerSupplyId OBJECT-TYPE
SYNTAX INTEGER(1..3)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The power supply Id."
::= { rcChasPowerSupplyEntry 1 }
rcChasPowerSupplyOperStatus OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
empty(2),
up(3),
down(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Actual status of the power supply:
- unknown(1) - status can not be determined.
- empty(2) - power supply not installed.
- up(3) - present and supplying power.
- down(4) - present, but failure indicated."
::= { rcChasPowerSupplyEntry 2 }
rcChasPowerSupplyDetailTable OBJECT-TYPE
SYNTAX SEQUENCE OF RcChasPowerSupplyDetailEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table contains detailed information about
power supplies."
::= { rcChasPowerSupply 2 }
rcChasPowerSupplyDetailEntry OBJECT-TYPE
SYNTAX RcChasPowerSupplyDetailEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Contains detailed info regarding a power supply
unit."
INDEX { rcChasPowerSupplyDetailId }
::= { rcChasPowerSupplyDetailTable 1 }
RcChasPowerSupplyDetailEntry ::=
SEQUENCE {
rcChasPowerSupplyDetailId INTEGER,
rcChasPowerSupplyDetailType INTEGER,
rcChasPowerSupplyDetailSerialNumber DisplayString,
rcChasPowerSupplyDetailHardwareRevision DisplayString,
rcChasPowerSupplyDetailPartNumber DisplayString,
rcChasPowerSupplyDetailDescription DisplayString,
rcChasPowerSupplyDetailPsePower INTEGER
}
rcChasPowerSupplyDetailId OBJECT-TYPE
SYNTAX INTEGER(1..3)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The power supply Id."
::= { rcChasPowerSupplyDetailEntry 1 }
rcChasPowerSupplyDetailType OBJECT-TYPE
SYNTAX INTEGER {
unknown(0),
ac(1),
dc(2),
poe(278798592) , -- 8300 110/200 V AC/DC PoE(0x109e2100)
poe1400WPS(278802688) -- 8300 110/200 V 850W/1400W AC/DC PoE(0x109e3100)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The power supply type."
::= { rcChasPowerSupplyDetailEntry 2 }
rcChasPowerSupplyDetailSerialNumber OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The power supply serial number."
::= { rcChasPowerSupplyDetailEntry 3 }
rcChasPowerSupplyDetailHardwareRevision OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The hardware revision of the power supply."
::= { rcChasPowerSupplyDetailEntry 4 }
rcChasPowerSupplyDetailPartNumber OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The power supply part number."
::= { rcChasPowerSupplyDetailEntry 5 }
rcChasPowerSupplyDetailDescription OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The detail description of power supply."
::= { rcChasPowerSupplyDetailEntry 6 }
rcChasPowerSupplyDetailPsePower OBJECT-TYPE
SYNTAX INTEGER (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The nominal power of the PSE expressed in Watts."
::= { rcChasPowerSupplyDetailEntry 7 }
rcCard OBJECT IDENTIFIER ::= { rcChassis 9 }
rcCardTable OBJECT-TYPE
SYNTAX SEQUENCE OF RcCardEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table that contains information about the
cards in this chassis. For those slots that
do not contain a physical card, the table may
be implemented to contain a conceptual row
with the type of physical module set to
'chasCardEmpty', or it may be implemented to
have no conceptual row instance."
::= { rcCard 1 }
rcCardEntry OBJECT-TYPE
SYNTAX RcCardEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Card attributes"
INDEX { rcCardIndex }
::= { rcCardTable 1 }
RcCardEntry ::=
SEQUENCE {
rcCardIndex INTEGER,
rcCardType INTEGER,
rcCardSerialNumber DisplayString,
rcCardHardwareRevision DisplayString,
rcCardAdminStatus INTEGER,
rcCardOperStatus INTEGER,
rcCardPCMCIAType INTEGER,
rcCardPartNumber DisplayString
}
rcCardIndex OBJECT-TYPE
SYNTAX INTEGER (1..10)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A unique value for each module within the chassis.
This value is determined by the chassis slot number
where the module is inserted. Valid entries are 1
to the value of rcChasNumSlots"
::= { rcCardEntry 1 }
rcCardType OBJECT-TYPE
SYNTAX INTEGER
{
other(1), -- no card installed
rcCPU(2), -- [1200] CPU Card (A1200)
rc8x100BaseTX(3), -- [1208TX] 8 port (cat 5) (A1200)
rc8x100BaseT2(4), -- [] 8 port (cat 3) (A1200)
rc8x100BaseF(5), -- [1208FX] 8 port fiber (A1200)
rc16x100BaseTX(6), -- [1216TX] 16 port (cat 5) (A1200)
rc8x100BaseTXWG(12), -- [1108TX] 8 port (half width) (A1100)
rc16x100BaseTXWG(13), -- [1100] 16 port + CPU (A1100)
rc4x100BaseFWG(14), -- [1104FX] 4 port (half width) (A1100)
rc12x100BaseTXWG(15), -- [1050] 12 port + CPU (A1050)
rc12x100BaseFBB(16), -- [] 12 port (A1200)
rc8x100BaseFWG(17), -- [1108FX] 8 port (A1100)
rc12x100BaseTX-2x100BaseFBB(18), -- [] 12 port + 2 port (A1200)
rc2x155BaseFBB(19), -- [] 2 sonet port (A1200)
rc4x155BaseFBB(20), -- [] 4 sonet port (A1200)
rc16x100BaseFBB(21), -- [1216FX] 16 port fiber (A1200)
rc14x100BaseTX-2x100BaseFBB(22), -- [1216TF] 14 port + 2 port (A1200)
rc8x10BaseFBB(23), -- [1208FL] 8 port fiber low-speed (A1200)
rc4xOC3(24), -- [1200xx] 4 port OC3 (A1200)
rc1xOC12(25), -- [1200xx] 1 port OC12 (A1200)
rcRMON(26), -- [1200xx] RMON (A1200)
rc1xOC12POSBaseMMF(27), -- [1200xx] 1 port OC12 POS (A1200)
rc1xOC12POSBaseSMF(28), -- [1200xx] 1 port OC12 POS (A1200)
rc4x1000BaseSXWG(1028), -- [1150] 1 0 00 000 0100 + CPU (A1150)
rc1x1000BaseSXWG(1025), -- [1101SX] 1 0 00 000 0001
rc2x1000BaseSXWG(1026), -- [1102SX] 1 0 00 000 0010
rc1x1000BaseSXRWG(1537), -- [1101SR] 1 1 00 000 0001
rc2x1000BaseSXRWG(1538), -- [1102SR] 1 1 00 000 0010
rc1x1000BaseLXWG(1153), -- [1101LX] 1 0 01 000 0001
rc2x1000BaseLXWG(1154), -- [1102LX] 1 0 01 000 0010
rc2x1000BaseXDWG(1282), -- [1102XD] 1 0 10 000 0010
rc1x1000BaseLXRWG(1665), -- [1101LR] 1 1 01 000 0001
rc2x1000BaseLXRWG(1666), -- [1102LR] 1 1 01 000 0010
rc1x1000BaseSXBB(1041), -- [1201SX] 1 0 00 001 0001
rc2x1000BaseSXBB(1042), -- [1202SX] 1 0 00 001 0010
rc1x1000BaseSXRBB(1553), -- [1201SR] 1 1 00 001 0001
rc2x1000BaseSXRBB(1554), -- [1202SR] 1 1 00 001 0010
rc1x1000BaseLXBB(1169), -- [1201LX] 1 0 01 001 0001
rc2x1000BaseLXBB(1170), -- [1202LX] 1 0 01 001 0010
rc2x1000BaseXDBB(1298), -- [1202XD] 1 0 10 001 0010
rc1x1000BaseLXRBB(1681), -- [1201LR] 1 1 01 001 0001
rc2x1000BaseLXRBB(1682) -- [1202LR] 1 1 01 001 0010
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Used to indicate a card types in the Accelar
1000 product families.
For Accelar 1000 devices, gigabit cards use
an encoded value according to the following rule:
+-----+--+-+---+---+---+
bits : |31-11|10|9|8-7|6-4|3-0|
+-----+--+-+---+---+---+
field : | a | b|c| d | e | f |
+-----+--+-+---+---+---+
a : not-used
b : 1=gigabit
c : 0=non-redundant,
1=redundant
d : 0=short-haul,
1=long-haul,
2=extra-distance,
e : 0=work-group(a1100 and a1150)
1=back-bone(a1200, f1250, and f2000),
f : 1=1-port, 2=2-port, 4=4-port, 8=8-port
"
::= { rcCardEntry 2 }
rcCardSerialNumber OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Unique serial number for this card."
::= { rcCardEntry 3 }
rcCardHardwareRevision OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..8))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Hardware Version"
::= { rcCardEntry 4 }
rcCardAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
up(1),
down(2),
testing(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to indicate the administrative status of this
card"
::= { rcCardEntry 5 }
rcCardOperStatus OBJECT-TYPE
SYNTAX INTEGER {
up(1),
down(2),
testing(3),
unknown(4),
dormant(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Used to indicate the operational status of this card."
::= { rcCardEntry 6 }
rcCardPCMCIAType OBJECT-TYPE
SYNTAX INTEGER {
none(1),
modem28kbs(2),
flash2meg(3),
flash4meg(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Used to indicate the type of PCMCIA card currently
installed in this CPU card, if any.
For non-CPU cards, this variable has no meaning and
will always be set to none."
DEFVAL { none }
::= { rcCardEntry 7 }
rcCardPartNumber OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..6))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Card Part Number"
::= { rcCardEntry 8 }
rcPort OBJECT IDENTIFIER ::= { rcChassis 10 } -- defined in rcPortXXX.mib
-- Additional Chassis Group Variables
rcChasAruMode OBJECT-TYPE
SYNTAX INTEGER
{
aruOne(1),
aruTwo(2),
aruThree(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The ARU mode the chassis is operating in."
::= { rcChassis 12 }
rcChasQuidMode OBJECT-TYPE
SYNTAX INTEGER
{
quidMixed(1),
quidTwo(2),
quidThree(3),
quidFour(4),
quidFive(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Quid mode the chassis is operating in."
::= { rcChassis 13 }
rcChasEocModeAdminStatus OBJECT-TYPE
SYNTAX INTEGER
{
default(0),
aru1Quid4(1),
aru2Quid4(2),
aru2Quid5(3),
aru3Quid4(4),
aru3Quid5(5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to specify the Enforce Operational
Configuration Mode(EOC) of the system. When a
device is configured with hardware of different
revisions, the system will initialize in some
deterministic manner (e.g., the lowest common
denominator that makes sense based on the hardware
configuration). This is the 'default(0)' mode.
The user can override this behavior by manually
specifying the EOC Mode they would like."
::= { rcChassis 14 }
-- Agent Table
rcAgentTable OBJECT-TYPE
SYNTAX SEQUENCE OF RcAgentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Agents in a chassis table"
::= { rcChassis 16 }
rcAgentEntry OBJECT-TYPE
SYNTAX RcAgentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Entry containing info. for a particular agent"
INDEX { rcAgentId }
::= { rcAgentTable 1 }
RcAgentEntry ::= SEQUENCE {
rcAgentId Integer32,
rcAgentSlot Integer32,
rcAgentIpAddr IpAddress
}
rcAgentId OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "entry id"
::= { rcAgentEntry 1 }
rcAgentSlot OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "slot agent is in."
::= { rcAgentEntry 2 }
rcAgentIpAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION "agent's ip address."
::= { rcAgentEntry 3 }
rcChasEocModeOperStatus OBJECT-TYPE
SYNTAX INTEGER
{
default(0),
aru1Quid4(1),
aru2Quid4(2),
aru2Quid5(3),
aru3Quid4(4),
aru3Quid5(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Used to indicate the Enforce Operational
Configuration Mode(EOC) of the system."
::= { rcChassis 15 }
rcChasBrouterPorts OBJECT-TYPE
SYNTAX PortSet
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Used to indicate which ports in the system are
configured as Brouter ports."
::= { rcChassis 17 }
rcChasGlobalFilterEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to enable/disable global filters in the
system. This variable is currently not supported."
DEFVAL { false }
::= { rcChassis 18 }
rcChasVlanBySrcMacEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to enable/disable source MAC based VLANs
in the system."
DEFVAL { false }
::= { rcChassis 19 }
rcChasDiffServEcnCompatibilityEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to enable/disable the Explicit Congestion
Notification(ECN) compatibility feature.
When set to FALSE , the system will mask the ECN bits
in the DS field while re-marking DSCP and will not match
on ECN capable flows if filter is set on DSmatch.
When set to TRUE, it will preserve the ECN bits in the DS
field while re-marking and will match on full 8-bit DS field."
DEFVAL { false }
::= { rcChassis 20 }
rcChasNewEnhancedOperMode OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Enhanced operational mode."
::= { rcChassis 21 }
rcChasNewEMMode OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "This configuration is for enabling/disabling 128K
mode. The change will take effect upon reboot."
::= { rcChassis 22 }
rcChasEmModeError OBJECT-TYPE
SYNTAX INTEGER {
none(1),
non128KCardOffLine(2),
checkSlaveConfigNResetForEmMMode(3),
mismatchResetForEmMode(4),
mismatchEmModeMasterSlave(5),
incompatMasterResetForEmMode(6),
putSlaveOffEmImcompat(7),
slave8690EmIncompatGoingOffline(8),
cpu8690DisableEm(9)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Used to indicate the Em-mode error status"
::= { rcChassis 23 }
rcChasEnhancedOperMode OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Enhanced Operational mode the switch currently has
booted and will remain the same unitl the next reboot."
::= { rcChassis 24 }
rcChasEMMode OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION "EM mode the switch currently has booted and
will remain the same unitl the next reboot."
::= { rcChassis 25 }
rcChasFtpDaemonInSecondaryCpu OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to enable/disable FTP daemon in 2nd cpu."
DEFVAL { false }
::= { rcChassis 26 }
rcChasSmltOnSingleCpEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Enable SMLT on single CP feature in the switch"
::= { rcChassis 27 }
rcChasNewVlanOptmMode OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Vlan Optimization mode."
::= { rcChassis 28 }
rcChasVlanOptmMode OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Vlan Optimization mode the switch currently has
booted and will remain the same unitl the next
reboot."
::= { rcChassis 29 }
-- defined in rcLaunchPadXXX.mib
rcLaunchPad OBJECT IDENTIFIER ::= { rcChassis 30 }
rcChasNaapEnable OBJECT-TYPE
SYNTAX EnableValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "To enable/disbale to napp feature."
::= { rcChassis 31 }
rcChasGlobalFilterOrderingEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to enable/disable global filter ordering
in the system."
DEFVAL { false }
::= { rcChassis 32 }
rcChasNewGlobalFilterOrderingEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "This configuration is for enabling/disabling
global filter ordering. The change will take
effect upon reboot."
DEFVAL { false }
::= { rcChassis 33 }
rcChasWsmDirectMode OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "This is for enabling/disabling configuration of same
community strings on the WSM and 8600. This if for
allowing users to connect directly via SNMP to the WSM
blade."
DEFVAL { false }
::= { rcChassis 34 }
rcChasRspMode OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "This configuration is for enabling/disabling 256K
mode. The change will take effect upon reboot."
::= { rcChassis 35 }
rcChasRspOperMode OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION "R-mode the switch currently has booted and
will remain the same until the next reboot."
::= { rcChassis 36 }
rcChasRspModeError OBJECT-TYPE
SYNTAX INTEGER {
none(1),
non256KCardOffLine(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Used to indicate the r-mode error status"
::= { rcChassis 37 }
rcChasPOE OBJECT IDENTIFIER ::= { rcChassis 38 }
rcChasPOEPower OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The total PoE power which this chassis
supports (Unit in Watts)."
::= { rcChasPOE 1 }
rcChasPOEAllocatedPower OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The total PoE power allocated for PoE modules
installed in this chassis (Unit in Watts)."
::= { rcChasPOE 2 }
rcChasPOEAvailablePower OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The total PoE power available for any
additional PoE power request or allocation
(Unit in Watts)."
::= { rcChasPOE 3 }
rcChasPOEBackUpPower OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The total PoE power reserved for backup or
redundancy (Unit in Watts)."
::= { rcChasPOE 4 }
-- rcRepeater
rcRepeater OBJECT IDENTIFIER ::= { rcChassis 39 }
rcRepeaterTable OBJECT-TYPE
SYNTAX SEQUENCE OF RcRepeaterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Port repeater table"
::= { rcRepeater 1 }
rcRepeaterEntry OBJECT-TYPE
SYNTAX RcRepeaterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Entry containing info. for a particular repeater"
INDEX { rcRepeaterId }
::= { rcRepeaterTable 1 }
RcRepeaterEntry ::= SEQUENCE {
rcRepeaterId INTEGER,
rcRepeaterFirstPort InterfaceIndex,
rcRepeaterSecondPort InterfaceIndex,
rcRepeaterVlanId INTEGER,
rcRepeaterName DisplayString,
rcRepeaterRowStatus RowStatus
}
rcRepeaterId OBJECT-TYPE
SYNTAX INTEGER(1..32)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A value that uniquely identifies the repeater."
::= { rcRepeaterEntry 1 }
rcRepeaterFirstPort OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-write
STATUS current
DESCRIPTION "First port member of the Repeater"
::= { rcRepeaterEntry 2 }
rcRepeaterSecondPort OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Second port member of the Repeater"
::= { rcRepeaterEntry 3 }
rcRepeaterVlanId OBJECT-TYPE
SYNTAX INTEGER (0..4094)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "A value that uniquely identifies the Virtual LAN
associated with first port"
::= { rcRepeaterEntry 4 }
rcRepeaterName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "An administratively-assigned name for this repeater."
::= { rcRepeaterEntry 5 }
rcRepeaterRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to create/delete entries in the rcRepeater."
::= { rcRepeaterEntry 6 }
rcChasMcastCheckPktEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to enable/disable Multicast check packet in the
system. This change will take effect upon reboot. "
DEFVAL { true }
::= { rcChassis 40 }
rcChasSystemMonitorEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Enable/Disable System monitoring in the switch"
DEFVAL { true }
::= { rcChassis 41 }
-- Dip-Switch Group
rcIsolateUnconfigPorts OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "Used to indicate whether ports that are unconfigured
should be assigned to the 'isolated' VLAN. Ports
assigned to the 'isolated' VLAN can only communicate
with the CP port. If this option is not specified,
unconfigured ports will be assigned to the 'default'
VLAN"
::= { rcDipSwitch 1 }
rcUseFactorySettings OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "Used to indicate whether the system should ignore
the configuration information stored in NVRAM when
the system is booted."
::= { rcDipSwitch 2 }
rcHighPriorityMode OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "Used to indicate whether the system is configured
to operate in a high priority mode. The switch can
operate in either a 'best effort' or 'high priority'
mode. In the 'best effort' setting, the maximum
queue thresholds for the QUIDs are set to 768/768
buffers. In the 'high priority' mode the setting
is 512/768. This means that in 'high priority' mode
the normal priority queue can't have more than 512
buffers, while the high priority queue can have up
to 768."
::= { rcDipSwitch 3 }
-- Table Size Group
rcTblRmonStatSize OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Used to indicate the current size of the RMON
Statistic table."
::= { rcTblSize 1 }
rcTblRmonHistoryControlSize OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Used to indicate the current size of the RMON
History Control table."
::= { rcTblSize 2 }
rcTblRmonHistoryEnetSize OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Used to indicate the current size of the RMON
History Ethernet table."
::= { rcTblSize 3 }
rcTblRmonAlarmSize OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Used to indicate the current size of the RMON
Alarm table."
::= { rcTblSize 4 }
rcTblRmonEventSize OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Used to indicate the current size of the RMON
Event table."
::= { rcTblSize 5 }
rcTblRmonLogSize OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Used to indicate the current size of the RMON
Log table."
::= { rcTblSize 6 }
rcTblArTblSize OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Used to indicate the size of the Address
Translation (AR) table."
::= { rcTblSize 7 }
rcTblArFree OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Used to indicate the number of free
entries that are available in the Address
Translation (AR) table."
::= { rcTblSize 8 }
rcTblArNoSpace OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Used to indicate the number of entries that could
not be added to the Address Translation (AR) table
due to lack of space."
::= { rcTblSize 9 }
rcTblArAdded OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Used to indicate the number of entries added to
the Address Translation (AR) table."
::= { rcTblSize 10 }
rcTblArDeleted OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Used to indicate the number of entries deleted to
the Address Translation (AR) table."
::= { rcTblSize 11 }
rcTblArMacAdded OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Used to indicate the number of MAC entries added to
the Address Translation (AR) table."
::= { rcTblSize 12 }
rcTblArMacDeleted OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Used to indicate the number of MAC entries deleted to
the Address Translation (AR) table."
::= { rcTblSize 13 }
rcTblArMacMoved OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Used to indicate the number of MAC entries moved in
the Address Translation (AR) table."
::= { rcTblSize 14 }
rcTblArIpAdded OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Used to indicate the number of IP entries added to
the Address Translation (AR) table."
::= { rcTblSize 15 }
rcTblArIpDeleted OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Used to indicate the number of IP entries deleted to
the Address Translation (AR) table."
::= { rcTblSize 16 }
rcTblArMcastTblSize OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Used to indicate the size of the Multicast
Address Translation (AR) table."
::= { rcTblSize 17 }
rcTblArFreeMcastGroups OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Used to indicate the number of free multicast
groups availabe in the Address Translation (AR)
table."
::= { rcTblSize 18 }
rcTblArIpMcastAdded OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Used to indicate the number of Ip multicast
entries that are added to the Address
Translation (AR) table."
::= { rcTblSize 19 }
rcTblArIpMcastDeleted OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Used to indicate the number of Ip multicast
entries that are deleted from the Address
Translation (AR) table."
::= { rcTblSize 20 }
rcTblArVlanByPortAdded OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Used to indicate the number of VLAN by port
entries that are added to the Address
Translation (AR) table."
::= { rcTblSize 21 }
rcTblArVlanByPortDeleted OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Used to indicate the number of VLAN by port
entries that are deleted from the Address
Translation (AR) table."
::= { rcTblSize 22 }
rcTblArVlanByProtocolAdded OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Used to indicate the number of Vlans by
Protocol Type entries that are added to
the Address Translation (AR) table."
::= { rcTblSize 23 }
rcTblArVlanByProtocolDeleted OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Used to indicate the number of Vlans by
Protocol Type entries that are deleted from
the Address Translation (AR) table."
::= { rcTblSize 24 }
rcTblArVlanByIpSubnetAdded OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Used to indicate the number of VLAN by Ip
entries that are added to the Address
Translation (AR) table."
::= { rcTblSize 25 }
rcTblArVlanByIpSubnetDeleted OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Used to indicate the number of VLAN by Ip
entries that are deleted from the Address
Translation (AR) table."
::= { rcTblSize 26 }
rcTblArIpSubnetsAdded OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Used to indicate the number of Ip subnet
entries that are added to the Address
Translation (AR) table."
::= { rcTblSize 27 }
rcTblArIpSubnetsDeleted OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Used to indicate the number of Ip subnet
entries that are deleted from the Address
Translation (AR) table."
::= { rcTblSize 28 }
rcTblArRsvpsAdded OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Used to indicate the number of RSVP
entries that are added to the Address
Translation (AR) table."
::= { rcTblSize 29 }
rcTblArRsvpsDeleted OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Used to indicate the number of RSVP
entries that are deleted from the Address
Translation (AR) table."
::= { rcTblSize 30 }
rcTblBrdgFdbSize OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Used to indicate the number of entries in the
dot1d forwarding database table."
::= { rcTblSize 31 }
rcTblBrdgStaticSize OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Used to indicate the number of entries in the
dot1d Static Address Filtering table."
::= { rcTblSize 32 }
rcTblIpAddrSize OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Used to indicate the number of entries in the
IP Address table."
::= { rcTblSize 33 }
rcTblIpForwardingSize OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Used to indicate the number of entries in the
IP Forwarding/Best Route table."
::= { rcTblSize 34 }
rcTblIpNetToMediaSize OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Used to indicate the number of entries in the
IP Net-to-media table."
::= { rcTblSize 35 }
rcTblIpBestPlusAltRouteSize OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION ""
::= { rcTblSize 36 }
rcTblIpBestPathSize OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION ""
::= { rcTblSize 37 }
rcTblIpBestPlusAltPathSize OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION ""
::= { rcTblSize 38 }
-- rcBoot Group
rcBootFlashSwVersion OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION "BootFlashSwVersion indicates the software
version in the Flash."
::= { rcBoot 1 }
rcBootPcmciaSwVersion OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION "BootPcmciaSwVersion indicate the software
version in the Pcmcia card."
::= { rcBoot 2 }
rcBootLastBootSource OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION "Indicates the boot source of the last
the system boot."
::= { rcBoot 3 }
rcBootPrimary OBJECT-TYPE
SYNTAX INTEGER {
flash(1),
pcmcia(2),
net(3),
skip(4)
}
MAX-ACCESS read-write
STATUS obsolete
DESCRIPTION "BootPrimary is indicator for the
primary source to boot the system."
DEFVAL { flash }
::= { rcBoot 4 }
rcBootSecondary OBJECT-TYPE
SYNTAX INTEGER {
flash(1),
pcmcia(2),
net(3),
skip(4)
}
MAX-ACCESS read-write
STATUS obsolete
DESCRIPTION "BootSecondary indicates the second choice
of the boot source."
DEFVAL { pcmcia }
::= { rcBoot 5 }
rcBootTertiary OBJECT-TYPE
SYNTAX INTEGER {
flash(1),
pcmcia(2),
net(3),
skip(4)
}
MAX-ACCESS read-write
STATUS obsolete
DESCRIPTION "BootTertiary indicates the third choice
of boot source."
DEFVAL { net }
::= { rcBoot 6 }
-- rcDevice Group
rcDeviceLastBootSource OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "Used to indicate the source of the software
image the system was last booted with."
::= { rcDevice 1 }
rcDevicePrimarySource OBJECT-TYPE
SYNTAX INTEGER {
flash(1),
pcmcia(2),
net(3),
skip(4)
}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION "Used to indicate the primary choice to get
a system software image."
::= { rcDevice 2 }
rcDevicePrimarySourceFileName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION "Used to indicate a file number, if applicable."
::= { rcDevice 3 }
rcDeviceSecondarySource OBJECT-TYPE
SYNTAX INTEGER {
flash(1),
pcmcia(2),
net(3),
skip(4)
}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION "Used to indicate the secondary choice to get
a system software image."
::= { rcDevice 4 }
rcDeviceSecondarySourceFileName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION "Used to indicate a file name, if applicable."
::= { rcDevice 5 }
rcDeviceTertiarySource OBJECT-TYPE
SYNTAX INTEGER {
flash(1),
pcmcia(2),
net(3),
skip(4)
}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION "Used to indicate the tertiary choice to get
a system software image."
::= { rcDevice 6 }
rcDeviceTertiarySourceFileName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION "Used to indicate a file name, if applicable."
::= { rcDevice 7 }
rcDeviceConfigSource OBJECT-TYPE
SYNTAX INTEGER {
flash(1),
pcmcia(2),
nvram(5)
}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION "Used to indicate the location to get a system
configuration file during system boot."
::= { rcDevice 8 }
rcDeviceConfigSourceFileName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION "Used to indicate a file name, if applicable."
::= { rcDevice 9 }
rcDeviceFlashBytesUsed OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "Used to indicate the number of bytes used in the
system's configuration flash device."
::= { rcDevice 10 }
rcDeviceFlashBytesFree OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "Used to indicate the number of bytes available in
the system's configuration flash device."
::= { rcDevice 11 }
rcDevicePcmciaBytesUsed OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "Used to indicate the number of bytes used in the
system's PCMCIA device."
::= { rcDevice 12 }
rcDevicePcmciaBytesFree OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "Used to indicate the number of bytes available in
the system's PCMCIA device."
::= { rcDevice 13 }
rcDeviceAction OBJECT-TYPE
SYNTAX INTEGER {
none(1),
squeezeFlash(2),
squeezePcmcia(3),
formatFlash(4),
formatPcmcia(5),
recoverFlash(6),
recoverPcmcia(7)
}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION "Used to specify a particular action to perform on
one of the system's device."
::= { rcDevice 14 }
rcDeviceResult OBJECT-TYPE
SYNTAX INTEGER {
none(1),
inProgress(2),
success(3),
fail(4)
}
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "Used to indicate the result of the last action
performed on one of the system's device."
::= { rcDevice 15 }
rcDeviceFlashNumFiles OBJECT-TYPE
SYNTAX INTEGER (0..128)
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "Used to indicate the number of files available in
the system's configuration flash device."
::= { rcDevice 16 }
rcDevicePcmciaNumFiles OBJECT-TYPE
SYNTAX INTEGER (0..128)
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "Used to indicate the number of files available in
the system's PCMCIA device."
::= { rcDevice 17 }
-- The Device Flash Table
rcDeviceFlashTable OBJECT-TYPE
SYNTAX SEQUENCE OF RcDeviceFlashEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION "Flash table."
::= { rcDevice 25 }
rcDeviceFlashEntry OBJECT-TYPE
SYNTAX RcDeviceFlashEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION "An entry in the system's flash table."
INDEX { rcDeviceFlashFileNum }
::= { rcDeviceFlashTable 1 }
RcDeviceFlashEntry ::=
SEQUENCE {
rcDeviceFlashFileNum INTEGER,
rcDeviceFlashFileName DisplayString,
rcDeviceFlashFileVersion DisplayString,
rcDeviceFlashFileType INTEGER,
rcDeviceFlashFileMode INTEGER,
rcDeviceFlashFileSize Integer32,
rcDeviceFlashFileCrc Integer32,
rcDeviceFlashFileStatus INTEGER,
rcDeviceFlashRowStatus RowStatus
}
rcDeviceFlashFileNum OBJECT-TYPE
SYNTAX INTEGER (0..128)
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "Used to indicate a particular file in flash."
::= { rcDeviceFlashEntry 1 }
rcDeviceFlashFileName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "Used to indicate a flash file's name."
::= { rcDeviceFlashEntry 2 }
rcDeviceFlashFileVersion OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "Used to indicate the flash file's version."
::= { rcDeviceFlashEntry 3 }
rcDeviceFlashFileType OBJECT-TYPE
SYNTAX INTEGER {
config(1),
log(2),
trace(3),
executable(4)
}
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "Used to indicate the flash file's type."
::= { rcDeviceFlashEntry 4 }
rcDeviceFlashFileMode OBJECT-TYPE
SYNTAX INTEGER {
compressed(1),
uncompressed(2)
}
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "Used to indicate the flash file's mode."
::= { rcDeviceFlashEntry 5 }
rcDeviceFlashFileSize OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "Used to indicate the flash file's size."
::= { rcDeviceFlashEntry 6 }
rcDeviceFlashFileCrc OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "Used to indicate the flash file's CRC."
::= { rcDeviceFlashEntry 7 }
rcDeviceFlashFileStatus OBJECT-TYPE
SYNTAX INTEGER {
active(1),
deleted(2)
}
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "Used to indicate the flash file's status.
A file that has been marked for deletion, but
who's space has not been reclaimed yet is marked
as 'deleted'."
::= { rcDeviceFlashEntry 8 }
rcDeviceFlashRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION "Row status."
::= { rcDeviceFlashEntry 9 }
-- The Device Pcmcia Table
rcDevicePcmciaTable OBJECT-TYPE
SYNTAX SEQUENCE OF RcDevicePcmciaEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION "PCMCIA table."
::= { rcDevice 26 }
rcDevicePcmciaEntry OBJECT-TYPE
SYNTAX RcDevicePcmciaEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION "An entry in the system's PCMCIA table."
INDEX { rcDevicePcmciaFileNum }
::= { rcDevicePcmciaTable 1 }
RcDevicePcmciaEntry ::=
SEQUENCE {
rcDevicePcmciaFileNum INTEGER,
rcDevicePcmciaFileName DisplayString,
rcDevicePcmciaFileVersion DisplayString,
rcDevicePcmciaFileType INTEGER,
rcDevicePcmciaFileMode INTEGER,
rcDevicePcmciaFileSize Integer32,
rcDevicePcmciaFileCrc Integer32,
rcDevicePcmciaFileStatus INTEGER,
rcDevicePcmciaRowStatus RowStatus
}
rcDevicePcmciaFileNum OBJECT-TYPE
SYNTAX INTEGER (0..128)
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "Used to indicate a particular file in PCMCIA."
::= { rcDevicePcmciaEntry 1 }
rcDevicePcmciaFileName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "Used to indicate the PCMCIA file's name."
::= { rcDevicePcmciaEntry 2 }
rcDevicePcmciaFileVersion OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "Used to indicate the PCMCIA file's version."
::= { rcDevicePcmciaEntry 3 }
rcDevicePcmciaFileType OBJECT-TYPE
SYNTAX INTEGER {
config(1),
log(2),
trace(3),
executable(4)
}
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "Used to indicate the PCMCIA file's type."
::= { rcDevicePcmciaEntry 4 }
rcDevicePcmciaFileMode OBJECT-TYPE
SYNTAX INTEGER {
compressed(1),
uncompressed(2)
}
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "Used to indicate a particular file in mode."
::= { rcDevicePcmciaEntry 5 }
rcDevicePcmciaFileSize OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "Used to indicate the PCMCIA file's size."
::= { rcDevicePcmciaEntry 6 }
rcDevicePcmciaFileCrc OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "Used to indicate the PCMCIA file's CRC."
::= { rcDevicePcmciaEntry 7 }
rcDevicePcmciaFileStatus OBJECT-TYPE
SYNTAX INTEGER {
active(1),
deleted(2)
}
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "Used to indicate the PCMCIA file's status.
A file that has been marked for deletion, but
who's space has not been reclaimed yet is marked
as 'deleted'."
::= { rcDevicePcmciaEntry 8 }
rcDevicePcmciaRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION "Row status."
::= { rcDevicePcmciaEntry 9 }
-- rcWeb related information
rcWebEnableServer OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Control whether the web server should be enabled.
Setting this variable to true will make the server
operational. Setting this variable to false will
disable server."
DEFVAL { false }
::= { rcWeb 1 }
rcWebRWAUserName OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..20))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "User name for the read-write-all web-server account."
::= { rcWeb 2 }
rcWebRWAPassword OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..20))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Password for the read-write-all web-server account."
::= { rcWeb 3 }
rcWebRWUserName OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..20))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "User name for the read-write web-server account."
::= { rcWeb 4 }
rcWebRWPassword OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..20))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Password for the read-write web-server account."
::= { rcWeb 5 }
rcWebROUserName OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..20))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "User name for the read-only web-server account."
::= { rcWeb 6 }
rcWebROPassword OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..20))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Password for the read-only web-server account."
::= { rcWeb 7 }
rcWebLastChange OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Last web-browser initiated configuration
change since sysUpTime."
::= { rcWeb 8 }
rcWebNumHits OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Number of hits to the web-server"
::= { rcWeb 9 }
rcWebNumAccessChecks OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Number of access checks performed by the web-server"
::= { rcWeb 10 }
rcWebNumAccessBlocks OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Number of accesses blocked by the web-server"
::= { rcWeb 11 }
rcWebNumRxErrors OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Number of receive errors encountered by the web-server"
::= { rcWeb 12 }
rcWebNumTxErrors OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Number of transmit errors encountered by the web-server"
::= { rcWeb 13 }
rcWebNumSetRequest OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Number of set-request to the web-server"
::= { rcWeb 14 }
rcWebPrimaryHtmlSourceDir OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "primary html source directory"
DEFVAL { "local" }
::= { rcWeb 15 }
rcWebSecondaryHtmlSourceDir OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "secondary html source directory"
DEFVAL { "pcmcia" }
::= { rcWeb 16 }
rcWebTertiaryHtmlSourceDir OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "tertiary html source directory"
::= { rcWeb 17 }
rcWebRWL3UserName OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..20))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "user name for the L3 web server account"
::= { rcWeb 18 }
rcWebRWL3Password OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..20))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "password for the L3 web server account"
::= { rcWeb 19 }
rcWebRWL2UserName OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..20))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "user name for the L2 web server account"
::= { rcWeb 20 }
rcWebRWL2Password OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..20))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "password for the L2 web server account"
::= { rcWeb 21 }
rcWebDefaultDisplayRows OBJECT-TYPE
SYNTAX INTEGER (10..100)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "default display rows in html page."
DEFVAL { 48 }
::= { rcWeb 22 }
rcWebLastHostAccessBlocked OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION "last host access blocked"
::= { rcWeb 23 }
rcWebHelpTftpSourceDir OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..256))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "tftp source directory for help files"
::= { rcWeb 24 }
rcWebHttpPort OBJECT-TYPE
SYNTAX INTEGER (1..49151)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "the HTTP port for web access"
DEFVAL { 80 }
::= { rcWeb 25 }
-- rcCli related information
rcCliRWAUserName OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..20))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "User name for the read-write-all CLI account."
::= { rcCli 1 }
rcCliRWAPassword OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Password for the read-write-all CLI account."
::= { rcCli 2 }
rcCliRWUserName OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..20))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "User name for the read-write CLI account."
::= { rcCli 3 }
rcCliRWPassword OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Password for the read-write CLI account."
::= { rcCli 4 }
rcCliRWL3UserName OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..20))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "User name for the read-write layer-3 CLI account."
::= { rcCli 5 }
rcCliRWL3Password OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Password for the read-write layer-3 CLI account."
::= { rcCli 6 }
rcCliRWL2UserName OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..20))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "User name for the read-write layer-2 CLI account."
::= { rcCli 7 }
rcCliRWL2Password OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Password for the read-write layer-2 CLI account."
::= { rcCli 8 }
rcCliROUserName OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..20))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "User name for the read-only CLI account."
::= { rcCli 9 }
rcCliROPassword OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Password for the read-only CLI account."
::= { rcCli 10 }
rcCliMaxTelnetSessions OBJECT-TYPE
SYNTAX INTEGER (0..8)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to indicate the maximum number of telnet
sessions the system will support."
DEFVAL { 8 }
::= { rcCli 11 }
rcCliMaxRloginSessions OBJECT-TYPE
SYNTAX INTEGER (0..8)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to indicate the maximum number of rlogin
sessions the system will support."
DEFVAL { 8 }
::= { rcCli 12 }
rcCliTimeout OBJECT-TYPE
SYNTAX INTEGER (30..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to indicate the amount of idle time, in
seconds to wait before timing out telnet and
rlogin sessions."
DEFVAL { 900 }
::= { rcCli 13 }
rcCliNumAccessViolations OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Used to indicate the number of CLI access
violations detected by the system."
::= { rcCli 14 }
rcCliRWL1UserName OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..20))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "User name for the read-write layer-1 CLI account."
::= { rcCli 15 }
rcCliRWL1Password OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Password for the read-write layer-1 CLI account."
::= { rcCli 16 }
rcCliPasswordChange OBJECT-TYPE
SYNTAX INTEGER {
ro(1),
l1(2),
l2(3),
l3(4),
rw(5),
rwa(6),
slboper(7),
l4oper(8),
oper(9),
slbadmin(10),
l4admin(11),
ssladmin(12),
commStrRo(13),
commStrRw(14),
commStrl3(15),
commStrl2(16),
commStrl1(17),
webPassWdRo(18)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Used to indication which password is changed when
sending a rcCliPasswordChange trap."
::= { rcCli 17 }
rcCliPassChangeResult OBJECT-TYPE
SYNTAX INTEGER {
success(1),
fail(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Used to indication the result of changing password when
sending a rcPasswordChange trap."
::= { rcCli 18 }
rcCliRWEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Enable/Disable for the read-write CLI account."
DEFVAL { true }
::= { rcCli 19 }
rcCliRWL1Enable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Enable/Disable for the read-write-layer1 CLI
account."
DEFVAL { true }
::= { rcCli 20 }
rcCliRWL2Enable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Enable/Disable for the read-write-layer2 CLI
account."
DEFVAL { true }
::= { rcCli 21 }
rcCliRWL3Enable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Enable/Disable for the read-write-layer3 CLI
account."
DEFVAL { true }
::= { rcCli 22 }
rcCliROEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Enable/Disable for the read-only CLI account."
DEFVAL { true }
::= { rcCli 23 }
-- Syslog Group
rcSyslogGlobal OBJECT IDENTIFIER ::= { rcSyslog 1 }
rcSyslogGlobalEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to enable/disable the SysLog feature. When
enabled this feature will send a message to a server
on a network that this configured to receive and
store diagnostic messages from this device. The
type of messages sent is user configurable."
DEFVAL { true }
::= { rcSyslogGlobal 1 }
rcSyslogGlobalMaxHosts OBJECT-TYPE
SYNTAX INTEGER (0..10)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Maximun number of remote hosts considered 'active'
and able to receive messages from the Syslog service
on the router."
DEFVAL { 5 }
::= { rcSyslogGlobal 2 }
rcSyslogGlobalOperState OBJECT-TYPE
SYNTAX INTEGER {
active(1),
inactive(2),
emptyHostTbl(3),
allHostDisabled(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The operational state of the syslog service
on the router."
DEFVAL { active }
::= { rcSyslogGlobal 3 }
rcSyslogHostTbl OBJECT-TYPE
SYNTAX SEQUENCE OF RcSyslogHostEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Table of remote host destinations for syslog."
::= { rcSyslog 2 }
rcSyslogHostEntry OBJECT-TYPE
SYNTAX RcSyslogHostEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Entry containing information for a particular
entry in rcSyslogHostTable."
INDEX { rcSyslogHostId }
::= { rcSyslogHostTbl 1 }
RcSyslogHostEntry ::= SEQUENCE {
rcSyslogHostId INTEGER,
rcSyslogHostIpAddr IpAddress,
rcSyslogHostUdpPort INTEGER,
rcSyslogHostFacility INTEGER,
rcSyslogHostModuleId INTEGER,
rcSyslogHostModuleId2 Integer32,
rcSyslogHostSeverity INTEGER,
rcSyslogHostMapInfoSeverity INTEGER,
rcSyslogHostMapWarningSeverity INTEGER,
rcSyslogHostMapErrorSeverity INTEGER,
rcSyslogHostMapMfgSeverity INTEGER,
rcSyslogHostMapFatalSeverity INTEGER,
rcSyslogHostMapTraceMsg INTEGER,
rcSyslogHostMapTrapMsg INTEGER,
rcSyslogHostLogTraceMsgs TruthValue,
rcSyslogHostLogTrapMsgs TruthValue,
rcSyslogHostEnable TruthValue,
rcSyslogHostRowStatus RowStatus
}
rcSyslogHostId OBJECT-TYPE
SYNTAX INTEGER (1..10)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Host Id."
::= { rcSyslogHostEntry 1 }
rcSyslogHostIpAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Host Ip Address"
::= { rcSyslogHostEntry 2 }
rcSyslogHostUdpPort OBJECT-TYPE
SYNTAX INTEGER (514..530)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Specifies the UDP port to use to send syslog
messages to the host."
DEFVAL { 514 }
::= { rcSyslogHostEntry 3 }
rcSyslogHostFacility OBJECT-TYPE
SYNTAX INTEGER {
local0(128),
local1(136),
local2(144),
local3(152),
local4(160),
local5(168),
local6(176),
local7(184)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Specifies the UNIX facility used in messages
to the syslog host. Default is LOCAL7."
DEFVAL { local7 }
::= { rcSyslogHostEntry 4 }
rcSyslogHostModuleId OBJECT-TYPE
SYNTAX INTEGER {
common (1), -- '00000001'H
snmp (2), -- '00000002'H
rmon (4), -- '00000004'H
portmgr (8), -- '00000008'H
chasmgr (16), -- '00000010'H
bridge (32), -- '00000020'H
ospf (64), -- '00000040'H
hwif (128), -- '00000080'H
sim (256), -- '00000100'H
cpp (512), -- '00000200'H
netdrv (1024), -- '00000400'H
vlanmgr (2048), -- '00000800'H
cli (4096), -- '00001000'H
main (8192), -- '00002000'H
p2ip (16384), -- '00004000'H
rcip (32768), -- '00008000'H
rompager (65536), -- '00010000'H
acif (131072), -- '00020000'H
gbip (262144), -- '00040000'H
wdt (524288), -- '00080000'H
tdp (1048576), -- '00100000'H
mandiag (2097152), -- '00200000'H
mantest (4194304), -- '00400000'H
igmp (8388608), -- '00800000'H
ipfil (16777216), -- '01000000'H
mlt (33554432), -- '02000000'H
ippolicy(67108864), -- '04000000'H
ipmc (134217728), -- '08000000'H
syslog (268435456) -- '10000000'H
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Specifies for which modules/tasks syslog messages
should be sent. Default is all modules/tasks."
::= { rcSyslogHostEntry 5 }
rcSyslogHostModuleId2 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Specifies for which modules/tasks syslog messages
should be sent. Default is all modules/tasks."
::= { rcSyslogHostEntry 6 }
rcSyslogHostSeverity OBJECT-TYPE
SYNTAX INTEGER (1..31)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Specifies the severity level for which syslog messages
should be sent for the modules specifies in
'SyslogHostModule'.
Value is one of multiple (logical 'OR') of the following:
info(1),
warning(2),
error(4),
mfg(8),
fatal(16)."
DEFVAL { 1 }
::= { rcSyslogHostEntry 7 }
rcSyslogHostMapInfoSeverity OBJECT-TYPE
SYNTAX INTEGER {
emergency(1),
alert(2),
critical(3),
error(4),
warning(5),
notice(6),
info(7),
debug(8)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Specifies the syslog severity to use for Accelar
INFO messages. Default is INFO."
DEFVAL { info }
::= { rcSyslogHostEntry 8 }
rcSyslogHostMapWarningSeverity OBJECT-TYPE
SYNTAX INTEGER {
emergency(1),
alert(2),
critical(3),
error(4),
warning(5),
notice(6),
info(7),
debug(8)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Specifies the syslog severity to use for Accelar
WARNING messages. Default is WARNING. Should be
less than or equal to INFO."
DEFVAL { warning }
::= { rcSyslogHostEntry 9 }
rcSyslogHostMapErrorSeverity OBJECT-TYPE
SYNTAX INTEGER {
emergency(1),
alert(2),
critical(3),
error(4),
warning(5),
notice(6),
info(7),
debug(8)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Specifies the syslog severity to use for Accelar
ERROR messages. Default is ERROR. Should be
less than or equal to WARNING."
DEFVAL { error }
::= { rcSyslogHostEntry 10 }
rcSyslogHostMapMfgSeverity OBJECT-TYPE
SYNTAX INTEGER {
emergency(1),
alert(2),
critical(3),
error(4),
warning(5),
notice(6),
info(7),
debug(8)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Specifies the syslog severity to use for Accelar
Manufactoring messages. Dafault is ERROR."
DEFVAL { error }
::= { rcSyslogHostEntry 11 }
rcSyslogHostMapFatalSeverity OBJECT-TYPE
SYNTAX INTEGER {
emergency(1),
alert(2),
critical(3),
error(4),
warning(5),
notice(6),
info(7),
debug(8)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Specifies the syslog severity to use for Accelar
FATAL messages. Default is EMERGENCY. Should be
less than or equal to ERROR."
DEFVAL { emergency }
::= { rcSyslogHostEntry 12 }
rcSyslogHostMapTraceMsg OBJECT-TYPE
SYNTAX INTEGER {
emergency(1),
alert(2),
critical(3),
error(4),
warning(5),
notice(6),
info(7),
debug(8)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Specifies the syslog severity to use for syslog
trace messages. Default is DEBUG."
::= { rcSyslogHostEntry 13 }
rcSyslogHostMapTrapMsg OBJECT-TYPE
SYNTAX INTEGER {
emergency(1),
alert(2),
critical(3),
error(4),
warning(5),
notice(6),
info(7),
debug(8)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Specifies the UNIX severity code to use for syslog
messages for SNMP traps sent to the syslog host.
Default is INFO."
::= { rcSyslogHostEntry 14 }
rcSyslogHostLogTraceMsgs OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Indicate whether to activate the host to log the
syslog trace messages."
::= { rcSyslogHostEntry 15 }
rcSyslogHostLogTrapMsgs OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Indicate whether to activate the host to log the
syslog messages for SNMP traps."
::= { rcSyslogHostEntry 16 }
rcSyslogHostEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Enable/Disable messages to be sent to syslog host."
DEFVAL { false }
::= { rcSyslogHostEntry 17 }
rcSyslogHostRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Used to create/delete entries in the rcSyslogTable."
::= { rcSyslogHostEntry 18 }
-- System Time Grp
rcUserSetTimeYear OBJECT-TYPE
SYNTAX INTEGER (1998..2097)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Year of the time."
DEFVAL {1998}
::= { rcUserSetTime 1 }
rcUserSetTimeMonth OBJECT-TYPE
SYNTAX INTEGER (1..12)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Month of the time."
DEFVAL {1}
::= { rcUserSetTime 2 }
rcUserSetTimeDate OBJECT-TYPE
SYNTAX INTEGER (1..31)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Date of the time."
DEFVAL {1}
::= { rcUserSetTime 3 }
rcUserSetTimeHour OBJECT-TYPE
SYNTAX INTEGER (0..23)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Hour of the time."
DEFVAL {0}
::= { rcUserSetTime 4 }
rcUserSetTimeMinute OBJECT-TYPE
SYNTAX INTEGER (0..59)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Minute of the time."
DEFVAL {0}
::= { rcUserSetTime 5 }
rcUserSetTimeSecond OBJECT-TYPE
SYNTAX INTEGER (0..59)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Second of the time."
DEFVAL {0}
::= { rcUserSetTime 6 }
-- RecRecord
rcRecReservTable OBJECT-TYPE
SYNTAX SEQUENCE OF RcRecReservEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table would display the statistics of several HW
record type used. This will also let the user reserve
certain number of records for each type."
::= { rcRec 1 }
rcRecReservTablEntry OBJECT-TYPE
SYNTAX RcRecReservEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX { rcRecReservRecordType }
::= { rcRecReservTable 1 }
RcRecReservEntry ::=
SEQUENCE {
rcRecReservRecordType INTEGER,
rcRecReservUsed Integer32,
rcRecReservReserved Integer32,
rcRecReservNewReserved Integer32,
rcRecReservDefReserved Integer32
}
rcRecReservRecordType OBJECT-TYPE
SYNTAX INTEGER {
filter(1),
ipmc(2),
local(3),
mac(4),
static(5),
vrrp(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "."
::= { rcRecReservTablEntry 1 }
rcRecReservUsed OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Displayes the number of HW records actually usee
by the recordType."
::= { rcRecReservTablEntry 2 }
rcRecReservReserved OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Displayes the number of HW records reserved for
the recordType."
::= { rcRecReservTablEntry 3 }
rcRecReservNewReserved OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Displayes the number of HW records that w ill
be reserved for this recordType after reset if the
configuration is saved."
::= { rcRecReservTablEntry 4 }
rcRecReservDefReserved OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Number of records reserved for this recordType
if loaded with factory default."
::= { rcRecReservTablEntry 5 }
-- SSH Group
-- SSH Global Information. All requires RWA access.
rcSshGlobal OBJECT IDENTIFIER ::= { rcSsh 1 }
rcSshGlobalVersion OBJECT-TYPE
SYNTAX INTEGER {
v2only(1),
both(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "SSH version"
DEFVAL { v2only }
::= { rcSshGlobal 1 }
rcSshGlobalPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "SSH connection port."
DEFVAL { 22 }
::= { rcSshGlobal 2 }
rcSshGlobalMaxSession OBJECT-TYPE
SYNTAX INTEGER (0..8)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Number of session allowed."
DEFVAL { 4 }
::= { rcSshGlobal 3 }
rcSshGlobalTimeout OBJECT-TYPE
SYNTAX INTEGER (1..120)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "SSH connection timeout in seconds."
DEFVAL { 60 }
::= { rcSshGlobal 4 }
rcSshGlobalRsaKeySize OBJECT-TYPE
SYNTAX INTEGER (0|512..1024)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "SSH Rsa key size."
DEFVAL { 1024 }
::= { rcSshGlobal 5 }
rcSshGlobalDsaKeySize OBJECT-TYPE
SYNTAX INTEGER (0|512..1024)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "SSH Dsa key size."
DEFVAL { 1024 }
::= { rcSshGlobal 6 }
rcSshGlobalRsaAuth OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Enable/disable SSH RSA authentication"
DEFVAL { true }
::= { rcSshGlobal 7 }
rcSshGlobalDsaAuth OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Enable/disable SSH DSA authentication"
DEFVAL { true }
::= { rcSshGlobal 8 }
rcSshGlobalPassAuth OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Enable/disable SSH RSA authentication"
DEFVAL { true }
::= { rcSshGlobal 9 }
rcSshGlobalKeyAction OBJECT-TYPE
SYNTAX INTEGER {
none(0),
generateDsa(1),
generateRsa(2),
deleteDsa(3),
deleteRsa(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "SSH key action."
::= { rcSshGlobal 10 }
rcSshGlobalEnable OBJECT-TYPE
SYNTAX INTEGER {
false(0),
true(1),
secure(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Enable/disable, or securely enable SSH. Securely enable
turns off other daemon flag, and it takes ffect afte reboot"
DEFVAL { false }
::= { rcSshGlobal 11 }
rcSshGlobalHostIpAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION "current remote ip addr"
::= { rcSshGlobal 12 }
rcSslMipTable OBJECT-TYPE
SYNTAX SEQUENCE OF RcSslMipEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table would display the MIP of the SSL blade
according to the slot number."
::= { rcSsh 2 }
rcSslMipTableEntry OBJECT-TYPE
SYNTAX RcSslMipEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table get the MIP of the SSL blade on which
the blade is in different cluster."
INDEX { rcSslMipSlot }
::= { rcSslMipTable 1 }
RcSslMipEntry ::=
SEQUENCE {
rcSslMipSlot Integer32,
rcSslMipMip DisplayString
}
rcSslMipSlot OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Used as an index to find out the MIP of SSL blade."
::= { rcSslMipTableEntry 1 }
rcSslMipMip OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Master IP of the SSL blade."
::= { rcSslMipTableEntry 2 }
-- LACP Group
-- LACP Global Information.
rcLacpGlobal OBJECT IDENTIFIER ::= { rcLacp 1 }
rcLacpGlobalEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "globally enable/disable LACP"
DEFVAL { false }
::= { rcLacpGlobal 1 }
rcLacpGlobalSystemPriority OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "set system priority to all the LACP enabled aggregators
and prots"
DEFVAL { 32768 }
::= { rcLacpGlobal 2 }
rcLacpGlobalFastPeriodicTime OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The number of miliseconds between periodic
transmissions using Short Timeouts. Set this
value to all LACP enabled ports."
DEFVAL { 1000 }
::= { rcLacpGlobal 3 }
rcLacpGlobalSlowPeriodicTime OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The number of miliseconds between periodic
transmissions using LONG Timeouts. Set this
value to all LACP enabled ports."
DEFVAL { 30000 }
::= { rcLacpGlobal 4 }
rcLacpGlobalTimeoutScale OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Scalar value used to calculate timeout time from
periodic time. Set this value to all LACP enabled ports."
DEFVAL { 3 }
::= { rcLacpGlobal 5 }
rcLacpGlobalAggrWaitTime OBJECT-TYPE
SYNTAX INTEGER (200..2000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The number of mili seconds to delay aggregation
to allow multiple links to aggregate simultaneously."
DEFVAL { 2000 }
::= { rcLacpGlobal 6 }
rcLacpGlobalVlacpEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "globally enable/disable Virtual LACP"
DEFVAL { false }
::= { rcLacpGlobal 7 }
rcLacpGlobalVlacpMulticastMACAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Virtual LACP multicast MAC address"
::= { rcLacpGlobal 8 }
-- rcVlacpPeerMacAddressTable
rcVlacpPeerMacAddressTable OBJECT-TYPE
SYNTAX SEQUENCE OF RcVlacpPeerMacAddressEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION " Virtual LACP Peer Mac Address table"
::= { rcLacp 2 }
rcVlacpPeerMacAddressEntry OBJECT-TYPE
SYNTAX RcVlacpPeerMacAddressEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Entry containing info. for a particular peer"
INDEX { rcVlacpPeerMacAddressMAC }
::= { rcVlacpPeerMacAddressTable 1 }
RcVlacpPeerMacAddressEntry ::= SEQUENCE {
rcVlacpPeerMacAddressMAC MacAddress,
rcVlacpPeerMacAddressMltId INTEGER,
rcVlacpPeerMacAddressPort InterfaceIndex,
rcVlacpPeerMacAddressIpAddr IpAddress,
rcVlacpPeerMacAddressRowStatus RowStatus
}
rcVlacpPeerMacAddressMAC OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Virtual LACP peer mac address on a port/MLT"
::= { rcVlacpPeerMacAddressEntry 1 }
rcVlacpPeerMacAddressMltId OBJECT-TYPE
SYNTAX INTEGER(1..32)
MAX-ACCESS read-create
STATUS current
DESCRIPTION "MLT Id on which Virtual LACP peer mac address is
directly or indirectly connected"
::= { rcVlacpPeerMacAddressEntry 2 }
rcVlacpPeerMacAddressPort OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Ports on which Virtual LACP peer mac address is
directly or indirectly connected"
::= { rcVlacpPeerMacAddressEntry 3 }
rcVlacpPeerMacAddressIpAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Virtual LACP peer Ip Address on port/MLT"
::= { rcVlacpPeerMacAddressEntry 4 }
rcVlacpPeerMacAddressRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Used to create/delete entries in the peer address table"
::= { rcVlacpPeerMacAddressEntry 5 }
END