pandorafms/pandora_console/attachment/mibs/PARALLEL-MIB

299 lines
8.3 KiB
Plaintext

-- Changes to RFC1660 - PARALLEL-MIB
-- Removed unused IMPORT of NOTIFICATION-TYPE
-- dperkins@scruznet.com
PARALLEL-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE,
Counter32, Integer32
FROM SNMPv2-SMI
InterfaceIndex
FROM IF-MIB
transmission
FROM RFC1213-MIB
MODULE-COMPLIANCE, OBJECT-GROUP
FROM SNMPv2-CONF;
para MODULE-IDENTITY
LAST-UPDATED "9405261700Z"
ORGANIZATION "IETF Character MIB Working Group"
CONTACT-INFO
" Bob Stewart
Postal: Xyplex, Inc.
295 Foster Street
Littleton, MA 01460
Tel: 508-952-4816
Fax: 508-952-4887
E-mail: rlstewart@eng.xyplex.com"
DESCRIPTION
"The MIB module for Parallel-printer-like hardware devices."
::= { transmission 34 }
-- Generic Parallel-printer-like information
paraNumber OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of ports (regardless of their current
state) in the Parallel-printer-like port table."
::= { para 1 }
-- the Parallel-printer-like Port table
paraPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF ParaPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of port entries. The number of entries is
given by the value of paraNumber."
::= { para 2 }
paraPortEntry OBJECT-TYPE
SYNTAX ParaPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Status and parameter values for a port."
INDEX { paraPortIndex }
::= { paraPortTable 1 }
ParaPortEntry ::=
SEQUENCE {
paraPortIndex
InterfaceIndex,
paraPortType
INTEGER,
paraPortInSigNumber
Integer32,
paraPortOutSigNumber
Integer32
}
paraPortIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of ifIndex for the port. By convention
and if possible, hardware port numbers map directly
to external connectors. The value for each port must
remain constant at least from one re-initialization
of the network management agent to the next."
::= { paraPortEntry 1 }
paraPortType OBJECT-TYPE
SYNTAX INTEGER {
other(1),
centronics(2),
dataproducts(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The port's hardware type."
::= { paraPortEntry 2 }
paraPortInSigNumber OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of input signals for the port in the
input signal table (paraPortInSigTable). The table
contains entries only for those signals the software
can detect and that are useful to observe."
::= { paraPortEntry 3 }
paraPortOutSigNumber OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of output signals for the port in the
output signal table (paraPortOutSigTable). The
table contains entries only for those signals the
software can assert and that are useful to observe."
::= { paraPortEntry 4 }
-- Parallel-printer-like Input Signal Table
paraInSigTable OBJECT-TYPE
SYNTAX SEQUENCE OF ParaInSigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of port input control signal entries."
::= { para 3 }
paraInSigEntry OBJECT-TYPE
SYNTAX ParaInSigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Input control signal status for a hardware port."
INDEX { paraInSigPortIndex, paraInSigName }
::= { paraInSigTable 1 }
ParaInSigEntry ::=
SEQUENCE {
paraInSigPortIndex
InterfaceIndex,
paraInSigName
INTEGER,
paraInSigState
INTEGER,
paraInSigChanges
Counter32
}
paraInSigPortIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of paraPortIndex for the port to which
this entry belongs."
::= { paraInSigEntry 1 }
paraInSigName OBJECT-TYPE
SYNTAX INTEGER { power(1), online(2), busy(3),
paperout(4), fault(5) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Identification of a hardware signal."
::= { paraInSigEntry 2 }
paraInSigState OBJECT-TYPE
SYNTAX INTEGER { none(1), on(2), off(3) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current signal state."
::= { paraInSigEntry 3 }
paraInSigChanges OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times the signal has changed from
'on' to 'off' or from 'off' to 'on'."
::= { paraInSigEntry 4 }
-- Output Signal Table
paraOutSigTable OBJECT-TYPE
SYNTAX SEQUENCE OF ParaOutSigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of port output control signal entries."
::= { para 4 }
paraOutSigEntry OBJECT-TYPE
SYNTAX ParaOutSigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Output control signal status for a hardware port."
INDEX { paraOutSigPortIndex, paraOutSigName }
::= { paraOutSigTable 1 }
ParaOutSigEntry ::=
SEQUENCE {
paraOutSigPortIndex
InterfaceIndex,
paraOutSigName
INTEGER,
paraOutSigState
INTEGER,
paraOutSigChanges
Counter32
}
paraOutSigPortIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of paraPortIndex for the port to which
this entry belongs."
::= { paraOutSigEntry 1 }
paraOutSigName OBJECT-TYPE
SYNTAX INTEGER { power(1), online(2), busy(3),
paperout(4), fault(5) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Identification of a hardware signal."
::= { paraOutSigEntry 2 }
paraOutSigState OBJECT-TYPE
SYNTAX INTEGER { none(1), on(2), off(3) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current signal state."
::= { paraOutSigEntry 3 }
paraOutSigChanges OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of times the signal has changed from
'on' to 'off' or from 'off' to 'on'."
::= { paraOutSigEntry 4 }
-- conformance information
paraConformance OBJECT IDENTIFIER ::= { para 5 }
paraGroups OBJECT IDENTIFIER ::= { paraConformance 1 }
paraCompliances OBJECT IDENTIFIER ::= { paraConformance 2 }
-- compliance statements
paraCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for SNMPv2 entities
which have Parallel-printer-like hardware
interfaces."
MODULE -- this module
MANDATORY-GROUPS { paraGroup }
::= { paraCompliances 1 }
-- units of conformance
paraGroup OBJECT-GROUP
OBJECTS { paraNumber, paraPortIndex, paraPortType,
paraPortInSigNumber, paraPortOutSigNumber,
paraInSigPortIndex, paraInSigName,
paraInSigState, paraInSigChanges,
paraOutSigPortIndex, paraOutSigName,
paraOutSigState, paraOutSigChanges }
STATUS current
DESCRIPTION
"A collection of objects providing information
applicable to all Parallel-printer-like interfaces."
::= { paraGroups 1 }
END