pandorafms/pandora_console/attachment/mibs/RFC1304-MIB

914 lines
37 KiB
Plaintext

-- Changes for RFC1304 (SIP MIB)
-- no changes needed.
-- dperkins@scruznet.com
RFC1304-MIB DEFINITIONS ::= BEGIN
IMPORTS
Counter, TimeTicks, IpAddress
FROM RFC1155-SMI
transmission
FROM RFC1213-MIB
OBJECT-TYPE
FROM RFC-1212;
-- This MIB module uses the extended OBJECT-TYPE macro
-- as defined in RFC-1212.
-- This is the MIB module for the SIP objects.
sip OBJECT IDENTIFIER ::= { transmission 31 }
-- All representations of SMDS addresses in this MIB
-- module use, as a textual convention (i.e., this
-- convention does not affect their encoding), the
-- data type:
SMDSAddress ::= OCTET STRING (SIZE (8))
-- the 60-bit SMDS address, preceded by 4 bits with the
-- following values:
-- "1100" when representing an individual address
-- "1110" when representing a group address
-- The SIP Level 3 group
-- Implementation of the SIP Level 3 group is mandatory
-- for all systems implementing SIP Level 3.
sipL3Table OBJECT-TYPE
SYNTAX SEQUENCE OF SipL3Entry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table contains SIP L3 parameters and
state variables, one entry per SIP port."
::= { sip 1 }
sipL3Entry OBJECT-TYPE
SYNTAX SipL3Entry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This list contains SIP L3 parameters and
state variables."
INDEX { sipL3Index }
::= { sipL3Table 1 }
SipL3Entry ::= SEQUENCE {
sipL3Index
INTEGER,
sipL3ReceivedIndividualDAs
Counter,
sipL3ReceivedGAs
Counter,
sipL3UnrecognizedIndividualDAs
Counter,
sipL3UnrecognizedGAs
Counter,
sipL3SentIndividualDAs
Counter,
sipL3SentGAs
Counter,
sipL3Errors
Counter,
sipL3InvalidSMDSAddressTypes
Counter,
sipL3VersionSupport
INTEGER
}
sipL3Index OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of this object identifies the SIP
port interface for which this entry contains
management information. The value of this
object for a particular interface has the same
value as the ifIndex object, defined in RFC
1156 and RFC 1213, for the same interface."
::= { sipL3Entry 1 }
sipL3ReceivedIndividualDAs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of individually addressed SIP
Level 3 PDUs received from the remote system
across the SNI. The total includes only
unerrored L3PDUs."
::= { sipL3Entry 2 }
sipL3ReceivedGAs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of group addressed SIP Level 3
PDUs received from the remote system across the
SNI. The total includes only unerrored L3PDUs."
::= { sipL3Entry 3 }
sipL3UnrecognizedIndividualDAs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of SIP Level 3 PDUs received from the
remote system with invalid or unknown individual
destination addresses (Destination Address
Screening violations are not included). See SMDS
Subscription MIB module."
::= { sipL3Entry 4 }
sipL3UnrecognizedGAs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of SIP Level 3 PDUs received from the
remote system with invalid or unknown group
addresses. (Destination Address Screening
violations are not included). See SMDS
Subscription MIB module."
::= { sipL3Entry 5 }
sipL3SentIndividualDAs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of individually addressed SIP Level 3
PDUs that have been sent by this system across the
SNI."
::= { sipL3Entry 6 }
sipL3SentGAs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of group addressed SIP L3PDUs that
have been sent by this system across the SNI."
::= { sipL3Entry 7 }
-- The total number of SIP L3PDU errors can be calculated as
-- (Syntactic errors + Semantic Service errors )
-- Syntactic errors include:
-- sipL3Errors
-- Latest occurrences of syntactic error types are logged in
-- sipL3PDUErrorTable.
-- Semantic Service errors include:
-- sipL3UnrecognizedIndividualDAs
-- sipL3UnrecognizedGAs
-- sipL3InvalidSMDSAddressTypes
-- Note that public networks supporting SMDS may discard
-- SIP L3PDUs due to subscription violations. Related
-- managed objects are defined in Definitions of Managed
-- Objects for SMDS Subscription.
sipL3Errors OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of SIP Level 3 PDUs received
from the remote system that were discovered to
have errors (including protocol processing and bit
errors but excluding addressing-related errors)
and were discarded. Includes both group addressed
L3PDUs and L3PDUs containing an individual
destination address."
::= { sipL3Entry 8 }
sipL3InvalidSMDSAddressTypes OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of SIP Level 3 PDUs received from the
remote system that had the Source or Destination
Address_Type subfields, (the four most significant
bits of the 64 bit address field), not equal to
the value 1100 or 1110. Also, an error is
considered to have occurred if the Address_Type
field for a Source Address, the four most
significant bits of the 64 bits, is equal to 1110
(a group address)."
::= { sipL3Entry 9 }
sipL3VersionSupport OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A value which indicates the version(s) of SIP
that this interface supports. The value is a sum.
This sum initially takes the value zero. For each
version, V, that this interface supports, 2 raised
to (V - 1) is added to the sum. For example, a
port supporting versions 1 and 2 would have a
value of (2^(1-1)+2^(2-1))=3. The
sipL3VersionSupport is effectively a bit mask with
Version 1 equal to the least significant bit
(LSB)."
::= { sipL3Entry 10 }
-- The SIP Level 2 group
-- Implementation of the SIP Level 2 group is mandatory
-- for all systems implementing SIP Level 2.
sipL2Table OBJECT-TYPE
SYNTAX SEQUENCE OF SipL2Entry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table contains SIP L2PDU parameters and
state variables, one entry per SIP port."
::= { sip 2 }
sipL2Entry OBJECT-TYPE
SYNTAX SipL2Entry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This list contains SIP L2 parameters and state
variables."
INDEX { sipL2Index }
::= { sipL2Table 1 }
SipL2Entry ::= SEQUENCE {
sipL2Index
INTEGER,
sipL2ReceivedCounts
Counter,
sipL2SentCounts
Counter,
sipL2HcsOrCRCErrors
Counter,
sipL2PayloadLengthErrors
Counter,
sipL2SequenceNumberErrors
Counter,
sipL2MidCurrentlyActiveErrors
Counter,
sipL2BomOrSSMsMIDErrors
Counter,
sipL2EomsMIDErrors
Counter
}
sipL2Index OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of this object identifies the SIP port
interface for which this entry contains management
information. The value of this object for a
particular interface has the same value as the
ifIndex object, defined in RFC 1156 and RFC 1213,
for the same interface."
::= { sipL2Entry 1 }
sipL2ReceivedCounts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of SIP Level 2 PDUs received from the
remote system across the SNI. The total includes
only unerrored L2PDUs."
::= { sipL2Entry 2 }
sipL2SentCounts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of SIP Level 2 PDUs that have been
sent by this system across the SNI."
::= { sipL2Entry 3 }
-- The total number of SIP L2PDU errors can be calculated as
-- the sum of:
-- sipL2HcsOrCRCErrors
-- sipL2PayloadLengthErrors
-- sipL2SequenceNumberErrors
-- sipL2MidCurrentlyActiveErrors
-- sipL2BomOrSSMsMIDErrors
-- sipL2EomsMIDErrors
sipL2HcsOrCRCErrors OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of received SIP Level 2 PDUs that were
discovered to have either a Header Check Sequence
error or a Payload CRC violation."
::= { sipL2Entry 4 }
sipL2PayloadLengthErrors OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of received SIP Level 2 PDUs that had
Payload Length errors that fall in the following
specifications:
- SSM L2_PDU payload length field value less
- than 28 octets or greater than 44 octets,
- BOM or COM L2_PDU payload length field not
- equal to 44 octets,
- EOM L2_PDU payload length field value less
- than 4 octets or greater than 44 octets."
::= { sipL2Entry 5 }
sipL2SequenceNumberErrors OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of received SIP Level 2 PDUs that had
a sequence number within the L2PDU not equal to
the expected sequence number of the SMDS SS
receive process."
::= { sipL2Entry 6 }
sipL2MidCurrentlyActiveErrors OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of received SIP Level 2 PDUs that are
BOMs for which an active receive process is
already started."
::= { sipL2Entry 7 }
sipL2BomOrSSMsMIDErrors OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of received SIP Level 2 PDUs that are
SSMs with a MID not equal to zero or are BOMs with
MIDs equal to zero."
::= { sipL2Entry 8 }
sipL2EomsMIDErrors OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of received SIP Level 2 PDUs that are
EOMs for which there is no active receive process
for the MID (i.e., the receipt of an EOM which
does not correspond to a BOM) OR the EOM has a MID
equal to zero."
::= { sipL2Entry 9 }
-- The SIP PLCP group
-- Implementation of one of these groups is mandatory
-- if the PLCP is implemented.
sipPLCP OBJECT IDENTIFIER ::= { sip 3 }
-- The SIP DS1 PLCP group
-- Implementation of this group is mandatory
-- if the DS1 PLCP is implemented.
sipDS1PLCPTable OBJECT-TYPE
SYNTAX SEQUENCE OF SipDS1PLCPEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table contains SIP DS1 PLCP parameters and
state variables, one entry per SIP port."
::= { sipPLCP 1 }
sipDS1PLCPEntry OBJECT-TYPE
SYNTAX SipDS1PLCPEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This list contains SIP DS1 PLCP parameters and
state variables."
INDEX { sipDS1PLCPIndex }
::= { sipDS1PLCPTable 1 }
SipDS1PLCPEntry ::= SEQUENCE {
sipDS1PLCPIndex
INTEGER,
sipDS1PLCPSEFSs
Counter,
sipDS1PLCPAlarmState
INTEGER,
sipDS1PLCPUASs
Counter
}
sipDS1PLCPIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of this object identifies the SIP port
interface for which this entry contains management
information. The value of this object for a
particular interface has the same value as the
ifIndex object, defined in RFC 1156 and RFC 1213,
for the same interface."
::= { sipDS1PLCPEntry 1 }
sipDS1PLCPSEFSs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A DS1 Severely Errored Framing Second (SEFS) is a
count of one-second intervals containing one or
more SEF events. A Severely Errored Framing (SEF)
event is declared when an error in the A1 octet
and an error in the A2 octet of a framing octet
pair (i.e., errors in both framing octets), or two
consecutive invalid and/or nonsequential Path
Overhead Identifier octets are detected."
::= { sipDS1PLCPEntry 2 }
sipDS1PLCPAlarmState OBJECT-TYPE
SYNTAX INTEGER {
noAlarm (1),
receivedFarEndAlarm (2),
incomingLOF (3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable indicates if there is an alarm
present for the DS1 PLCP. The value
receivedFarEndAlarm means that the DS1 PLCP has
received an incoming Yellow Signal, the value
incomingLOF means that the DS1 PLCP has declared a
loss of frame (LOF) failure condition, and the
value noAlarm means that there are no alarms
present. See TR-TSV-000773 for a description of
alarm states."
::= { sipDS1PLCPEntry 3 }
sipDS1PLCPUASs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The counter associated with the number of
Unavailable Seconds, as defined by TR-TSV-000773,
encountered by the PLCP."
::= { sipDS1PLCPEntry 4 }
-- The SIP DS3 PLCP group
-- Implementation of this group is mandatory
-- if the DS3 PLCP is implemented.
sipDS3PLCPTable OBJECT-TYPE
SYNTAX SEQUENCE OF SipDS3PLCPEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table contains SIP DS3 PLCP parameters and
state variables, one entry per SIP port."
::= { sipPLCP 2 }
sipDS3PLCPEntry OBJECT-TYPE
SYNTAX SipDS3PLCPEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This list contains SIP DS3 PLCP parameters and
state variables."
INDEX { sipDS3PLCPIndex }
::= { sipDS3PLCPTable 1 }
SipDS3PLCPEntry ::= SEQUENCE {
sipDS3PLCPIndex
INTEGER,
sipDS3PLCPSEFSs
Counter,
sipDS3PLCPAlarmState
INTEGER,
sipDS3PLCPUASs
Counter
}
sipDS3PLCPIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of this object identifies the SIP port
interface for which this entry contains management
information. The value of this object for a
particular interface has the same value as the
ifIndex object, defined in RFC 1156 and RFC 1213,
for the same interface."
::= { sipDS3PLCPEntry 1 }
sipDS3PLCPSEFSs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A DS3 Severely Errored Framing Second (SEFS) is a
count of one-second intervals containing one or
more SEF events. A Severely Errored Framing (SEF)
event is declared when an error in the A1 octet
and an error in the A2 octet of a framing octet
pair (i.e., errors in both framing octets), or two
consecutive invalid and/or nonsequential Path
Overhead Identifier octets are detected."
::= { sipDS3PLCPEntry 2 }
sipDS3PLCPAlarmState OBJECT-TYPE
SYNTAX INTEGER {
noAlarm (1),
receivedFarEndAlarm (2),
incomingLOF (3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable indicates if there is an alarm
present for the DS3 PLCP. The value
receivedFarEndAlarm means that the DS3 PLCP has
received an incoming Yellow Signal, the value
incomingLOF means that the DS3 PLCP has declared a
loss of frame (LOF) failure condition, and the
value noAlarm means that there are no alarms
present. See TR-TSV-000773 for a description of
alarm states."
::= { sipDS3PLCPEntry 3 }
sipDS3PLCPUASs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The counter associated with the number of
Unavailable Seconds, as defined by TR-TSV-000773,
encountered by the PLCP."
::= { sipDS3PLCPEntry 4 }
-- The SMDS Applications group
-- Applications that have been identified for this group are:
-- * IP-over-SMDS (details are specified in RFC 1209)
-- Implementation of this group is mandatory for systems
-- that implement IP-over-SMDS Interface Protocol.
smdsApplications OBJECT IDENTIFIER ::= { sip 4 }
ipOverSMDS OBJECT IDENTIFIER ::= { smdsApplications 1 }
-- Although the objects in this group are read-only, at the
-- agent's discretion they may be made read-write so that the
-- management station, when appropriately authorized, may
-- change the addressing information related to the
-- configuration of a logical IP subnetwork implemented on
-- top of SMDS.
-- This table is necessary to support RFC1209 (IP-over-SMDS)
-- and gives information on the Group Addresses and ARP
-- Addresses used in the Logical IP subnetwork.
-- One SMDS address may be associated with multiple IP
-- addresses. One SNI may be associated with multiple LISs.
ipOverSMDSTable OBJECT-TYPE
SYNTAX SEQUENCE OF IpOverSMDSEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The table of addressing information relevant to
this entity's IP addresses."
::= { ipOverSMDS 1 }
ipOverSMDSEntry OBJECT-TYPE
SYNTAX IpOverSMDSEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The addressing information for one of this
entity's IP addresses."
INDEX { ipOverSMDSIndex, ipOverSMDSAddress }
::= { ipOverSMDSTable 1 }
IpOverSMDSEntry ::=
SEQUENCE {
ipOverSMDSIndex
INTEGER,
ipOverSMDSAddress
IpAddress,
ipOverSMDSHA
SMDSAddress,
ipOverSMDSLISGA
SMDSAddress,
ipOverSMDSARPReq
SMDSAddress
}
ipOverSMDSIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of this object identifies the SIP port
interface for which this entry contains management
information. The value of this object for a
particular interface has the same value as the
ifIndex object, defined in RFC 1156 and RFC 1213,
for the same interface."
::= { ipOverSMDSEntry 1 }
ipOverSMDSAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The IP address to which this entry's addressing
information pertains."
::= { ipOverSMDSEntry 2 }
ipOverSMDSHA OBJECT-TYPE
SYNTAX SMDSAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The SMDS Individual address of the IP station."
::= { ipOverSMDSEntry 3 }
ipOverSMDSLISGA OBJECT-TYPE
SYNTAX SMDSAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The SMDS Group Address that has been configured
to identify the SMDS Subscriber-Network Interfaces
(SNIs) of all members of the Logical IP Subnetwork
(LIS) connected to the network supporting SMDS."
::= { ipOverSMDSEntry 4 }
ipOverSMDSARPReq OBJECT-TYPE
SYNTAX SMDSAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The SMDS address (individual or group) to which
ARP Requests are to be sent."
::= { ipOverSMDSEntry 5 }
-- The SMDS Carrier Selection group
-- This group is used as a place holder
-- for carrier selection objects.
smdsCarrierSelection OBJECT IDENTIFIER ::= { sip 5}
-- The SIP Error Log
-- Implementation of this group is mandatory
-- for all systems that implement SIP Level 3.
sipErrorLog OBJECT IDENTIFIER ::= { sip 6 }
sipL3PDUErrorTable OBJECT-TYPE
SYNTAX SEQUENCE OF SipL3PDUErrorEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table that contains the latest occurrence of
the following syntactical SIP L3PDU errors:
- Destination Address Field Format Error,
The following pertains to the 60 least significant
bits of the 64 bit address field. The 60 bits
contained in the address subfield can be used to
represent addresses up to 15 decimal digits. Each
decimal digit shall be encoded into four bits
using Binary Coded Decimal (BCD), with the most
significant digit occurring left-most. If not all
15 digits are required, then the remainder of this
field shall be padded on the right with bits set
to one. An error is considered to have occurred:
a). if the first four bits of the address
subfield are not BCD, OR b). if the first four
bits of the address subfield are populated with
the country code value 0001, AND the 40 bits which
follow are not Binary Coded Decimal (BCD) encoded
values of the 10 digit addresses, OR the remaining
16 least significant bits are not populated with
1's, OR c). if the address subfield is not
correct according to another numbering plan which
is dependent upon the carrier assigning the
numbers and offering SMDS.
- Source Address Field Format Error,
The description of this parameter is the same as
the description of the Destination Address Field
Format Error.
- Invalid BAsize Field Value,
An error is considered to have occurred when the
BAsize field of an SIP L3PDU contains a value less
that 32, greater than 9220 octets without the
CRC32 field present, greater than 9224 octets with
the CRC32 field present, or not equal to a
multiple of 4 octets,
- Invalid Header Extension Length Field Value,
An error is considered to have occurred when the
Header Extension Length field value is not equal
3.
- Invalid Header Extension - Element Length,
An error is considered to have occurred when the
Header Extension - Element Length is greater than
12.
- Invalid Header Extension - Version Element
Position, Length, or Value,
An error is considered to have occurred when a
Version element with Length=3, Type=0, and Value=1
does not appear first within the Header Extension,
or an element Type=0 appears somewhere other than
within the first three octets in the Header
Extension.
- Invalid Header Extension - Carrier Selection
Element Position, Length, Value or Format,
An error is considered to have occurred when a
Carrier Selection element does not appear second
within the Header Extension, if the Element Type
does not equal 1, the Element Length does not
equal 4, 6, or 8, the Element Value field is not
four BCD encoded decimal digits used in specifying
the Carrier Identification Code (CIC), or the
identified CIC code is invalid.
- Header Extension PAD Error
An error is considered to have occurred when the
Header Extension PAD is 9 octets in length, or if
the Header Extension PAD is greater than zero
octets in length and the Header Extension PAD does
not follow all Header Extension elements or does
not begin with at least one octet of all zeros.
- BEtag Mismatch Error,
An error is considered to have occurred when the
Beginning-End Tags in the SIP L3PDU header and
trailer are not equal.
- BAsize Field not equal to Length Field Error,
An error is considered to have occurred when the
value of the BAsize Field does not equal the value
of the Length Field.
- Incorrect Length Error, and
An error is considered to have occurred when the
the Length field value is not equal to the portion
of the SIP L3PDU which extends from the
Destination Address field up to and including the
CRC32 field (if present) or up to and including
the PAD field (if the CRC32 field is not present).
As an optional check, an error is considered to
have occurred when the length of a partially
received SIP L3PDU exceeds the BAsize value.
- MRI Timeout Error.
An error is considered to have occurred when the
elapsed time between receipt of BOM and
corresponding EOM exceeds the value of the MRI
(Message Receive Interval) for a particular
transport signal format.
An entry is indexed by interface number and error
type, and contains Source Address, Destination
Address and a timestamp. All these errors are
counted in the sipL3Errors counter. When
sipL3PDUErrorTimeStamp is equal to zero, the
SipL3PDUErrorEntry does not contain any valid
information."
::= { sipErrorLog 1 }
sipL3PDUErrorEntry OBJECT-TYPE
SYNTAX SipL3PDUErrorEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the service disagreement table."
INDEX { sipL3PDUErrorIndex, sipL3PDUErrorType }
::= { sipL3PDUErrorTable 1 }
SipL3PDUErrorEntry ::= SEQUENCE {
sipL3PDUErrorIndex
INTEGER,
sipL3PDUErrorType
INTEGER,
sipL3PDUErrorSA
SMDSAddress,
sipL3PDUErrorDA
SMDSAddress,
sipL3PDUErrorTimeStamp
TimeTicks
}
sipL3PDUErrorIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of this object identifies the SIP port
interface for which this entry contains management
information. The value of this object for a
particular interface has the same value as the
ifIndex object, defined in RFC 1156 and RFC 1213,
for the same interface."
::= { sipL3PDUErrorEntry 1 }
sipL3PDUErrorType OBJECT-TYPE
SYNTAX INTEGER {
erroredDAFieldFormat (1),
erroredSAFieldFormat (2),
invalidBAsizeFieldValue (3),
invalidHdrExtLength (4),
invalidHdrExtElementLength (5),
invalidHdrExtVersionElementPositionLenthOrValue (6),
invalidHdrExtCarSelectElementPositionLenghtValueOrFormat (7),
hePADError (8),
beTagMismatch (9),
baSizeFieldNotEqualToLengthField (10),
incorrectLength (11),
mriTimeout (12)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The type of error."
::= { sipL3PDUErrorEntry 2 }
sipL3PDUErrorSA OBJECT-TYPE
SYNTAX SMDSAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A rejected SMDS source address."
::= { sipL3PDUErrorEntry 3 }
sipL3PDUErrorDA OBJECT-TYPE
SYNTAX SMDSAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A rejected SMDS destination address."
::= { sipL3PDUErrorEntry 4 }
sipL3PDUErrorTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The timestamp for the service disagreement. The
timestamp contains the value of sysUpTime at the
latest occurrence of this type of service
disagreement. See textual description under
sipL3PDUErrorTable for boundary conditions."
::= { sipL3PDUErrorEntry 5 }
END