pandorafms/pandora_console/attachment/mibs/CISCO-STACK-MIB.my

12612 lines
540 KiB
Plaintext

-- *****************************************************************
-- CISCO-STACK-MIB.my
--
-- June 1995, Fei Xu
--
-- Copyright (c) 1995-2005 by cisco Systems, Inc.
-- All rights reserved.
-- *****************************************************************
--
CISCO-STACK-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, IpAddress, TimeTicks,
Counter32, Counter64, Unsigned32, NOTIFICATION-TYPE
FROM SNMPv2-SMI
DisplayString, RowStatus, TruthValue, MacAddress,
TEXTUAL-CONVENTION
FROM SNMPv2-TC
fddimibPORTSMTIndex, fddimibPORTIndex
FROM FDDI-SMT73-MIB
OwnerString, ifName, ifIndex
FROM IF-MIB
MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP
FROM SNMPv2-CONF
workgroup
FROM CISCO-SMI
ringStationMacAddress
FROM TOKEN-RING-RMON-MIB
PhysicalIndex
FROM ENTITY-MIB
VlanIndex
FROM CISCO-VTP-MIB;
ciscoStackMIB MODULE-IDENTITY
LAST-UPDATED "200703300000Z"
ORGANIZATION "Cisco Systems, Inc."
CONTACT-INFO
" Cisco Systems
Customer Service
Postal: 170 W Tasman Drive
San Jose, CA 95134
USA
Tel: +1 800 553-NETS
E-mail: cs-wbu@cisco.com,
cs-lan-switch-snmp@cisco.com"
DESCRIPTION
"This MIB provides configuration and runtime status for
chassis, modules, ports, etc. on the Catalyst systems."
REVISION "200703300000Z"
DESCRIPTION
"Modified chassisSysType to include:
'mec6524gs8s', 'mec6524gt8s', 'cisco7603s'.
Updated chassisPs1Type and chassisPs2Type to include:
'pwr400dc', 'pwr400ac'.
Updated chassisComponentType for new hardwares:
'fan6524', 'fanMod6Shs', 'fanMod9Shs', 'fanMod9St',
'fanMod3Hs'.
Modified moduleType to include:
'mec6524gs8s', 'mec6524gt8s', 'me6524msfc2a',
'wsx670810ge'.
Updated moduleSubType to include new hardwares:
'mec6524pfc3c', 'wsf6700dfc3c', 'wsf6700dfc3cxl'.
Modified VendorIdType to compliance with SNMP v2
format"
REVISION "200510280000Z"
DESCRIPTION
"Modified chassisComponentType to include:
'fanMod4Hs'.
Modified syslogMessageFacility to include:
'eou', 'backup', 'eoam', 'webauth'.
Modified sysErrDisableTimeoutEnable to include:
'ethernetOam', 'gl2ptEoamThresholdExceed'.
Updated chassisPs1Type and chassisPs2Type to include:
'pwr2700dc', 'pwr2700ac4', 'pwr2700dc4', and
'wscac8700we'.
Modified moduleType to include:
'osm4oc3PosMM', 'wsx6196rj21',
'wssup32ge3b', 'wsSvcIpSec1',
'wsx6148arj45', 'wsSvcWebVpnk9',
'ace106500k9', 'ace046500k9',
'wsSvcAdm1k9', 'wsSvcAgm1k9',
'wssup3210ge3b', 'osm2choc12T3SI',
'wsf6700cfc', 'osm8choc3DS0SI'.
Updated portType to include:
'e10GBaseEdc1310', 'e10GBaseSW',
'sslVpn', 'adsm',
'agsm', 'aces',
'e10GBaseZR', 'e100BaseEX',
'e100BaseZX'."
REVISION "200504270000Z"
DESCRIPTION
"Added support of the following objects:
cisco7604sysID, wsc6504esysID
Modified sysEnableStpxTrap to include:
'enabledForInconOnly', 'enabledForRootOnly',
'enabledForLoopOnly', 'enabledForInconRootOnly',
'enabledForInconLoopOnly', 'enabledForRootLoopOnly'
Modified sysErrDisableTimeoutEnable to include:
'camMonitor', 'gl2ptCdpThresholdExceed',
'gl2ptStpThresholdExceed', 'gl2ptVtpThresholdExceed',
'linkRxCrc', 'linkTxCrc',
'linkInErrors', 'packetBufferError'
Updated chassisSysType for new hardwares:
cisco7604 and wsc6504e
Updated chassisPs1Type and chassisPs2Type for new
hardwares:
wscac6000w and pwr2700ac
Updated chassisComponentType for new hardwares:
wsc6506eFan, wsc6509eFan, wsc6503eFan, wsc6000vtte.
Updated moduleType for hardware:
osm2oc48OneDptSSDual, osm2oc48OneDptSIDual,
osm2oc48OneDptSLDual, osm4choc12T3MM,
osm4choc12T3SI, osm8choc12T3MM,
osm8choc12T3SI, osm2choc48T3SS,
osm1choc48T3SI, osm2choc48T3SI,
osm4choc3DS0SI, osm1choc12T1SI,
osm12ct3T1, osm24t3e3,
osm2oc12AtmMMPlus, osm2oc12AtmSIPlus,
osm8oc3PosSLPlus, wsx6516aGbic,
wsx6148getx, wsSvcWlan1k9,
wsSvcAon1k9, wsx6148FeSfp,
wsx65822pa
Updated moduleType for name changed:
wsx61821pa changed to wsx61822pa
Updated moduleSubType to include new hardwares:
wsf6700dfc3a, wsf6kdfc3bxl,
wsf6kpfc3bxl, wsf6700dfc3bxl,
wsf6700dfc3b, wsf6kdfc3b
Updated moduleSubType to include new hardwares:
wssvccmm6e1, wssvccmm6t1,
wssvccmm24fxs, wssvccmmact
Updated portType to include:
e10GBaseWdm1550, e10GBaseLW,
e10GBaseEW, lwa,
aons, e100BaseEmpty,
e100BaseUnknown, e100BaseUnapproved,
e100BaseSX, e100BaseBX10D,
e100BaseBX10U, e1000BaseBX10D,
e1000BaseBX10U, e10GBaseBad
Updated portType for name changed:
posOc48mm changed to posOc48sms
Modified ipPermitAccessType, ipPermitDeniedAccess,
ipPermitAccessTypeEnable to include:
http
Modified syslogMessageFacility to include:
diags
Modified portCpbInlinePower to include:
static
Deprecated sysEnableStpxTrap, replaced by
stpxNotificationEnable in
CISCO-STP-EXTENSIONS-MIB.my
Deprecated radiusServerTable, replaced by
crRadiusServerTable in CISCO-RADIUS-MIB.my
Added new conformance Groups:
optionalSystemTrapGroup1,
authenticationGroup2,
systemTrapGroup2,
notificationGroup."
REVISION "200405140000Z"
DESCRIPTION
"Modified sysEnableBridgeTraps to include:
'enabledForNewRootOnly' and 'enabledForTopoChangeOnly'
Updated moduleType for new hardwares:
wsx2948ggetx, wsx2948ggetxgbrj and wsx6748sfp
Updated moduleSubType for the new harware:
wsf6kpfc3b
Updated moduleSubType2 for the new harware:
wsf6kVpwrGe
Updated portType to include:
e10GBaseSR, e10GBaseCX4,
e1000BaseUnknown and e10GBaseUnknown,
e10GBaseUnapproved, e1000BaseWdmRxOnly,
e1000BaseDwdm3033,e1000BaseDwdm3112,
e1000BaseDwdm3190,e1000BaseDwdm3268,
e1000BaseDwdm3425,e1000BaseDwdm3504,
e1000BaseDwdm3582,e1000BaseDwdm3661,
e1000BaseDwdm3819,e1000BaseDwdm3898,
e1000BaseDwdm3977,e1000BaseDwdm4056,
e1000BaseDwdm4214,e1000BaseDwdm4294,
e1000BaseDwdm4373,e1000BaseDwdm4453,
e1000BaseDwdm4612,e1000BaseDwdm4692,
e1000BaseDwdm4772,e1000BaseDwdm4851,
e1000BaseDwdm5012,e1000BaseDwdm5092,
e1000BaseDwdm5172,e1000BaseDwdm5252,
e1000BaseDwdm5413,e1000BaseDwdm5494,
e1000BaseDwdm5575,e1000BaseDwdm5655,
e1000BaseDwdm5817,e1000BaseDwdm5898,
e1000BaseDwdm5979,e1000BaseDwdm6061,
e10GBaseWdmRxOnly, e10GBaseDwdm3033,
e10GBaseDwdm3112, e10GBaseDwdm3190
e10GBaseDwdm3268, e10GBaseDwdm3425,
e10GBaseDwdm3504, e10GBaseDwdm3582,
e10GBaseDwdm3661, e10GBaseDwdm3819,
e10GBaseDwdm3898, e10GBaseDwdm3977,
e10GBaseDwdm4056, e10GBaseDwdm4214,
e10GBaseDwdm4294, e10GBaseDwdm4373,
e10GBaseDwdm4453, e10GBaseDwdm4612,
e10GBaseDwdm4692, e10GBaseDwdm4772,
e10GBaseDwdm4851, e10GBaseDwdm5012,
e10GBaseDwdm5092, e10GBaseDwdm5172,
e10GBaseDwdm5252, e10GBaseDwdm5413,
e10GBaseDwdm5494, e10GBaseDwdm5575,
e10GBaseDwdm5655, e10GBaseDwdm5817,
e10GBaseDwdm5898, e10GBaseDwdm5979 and
e10GBaseDwdm6061
Modified portAdminSpeed to include:
'autoDetect10100'
Modified syslogMessageFacility to include:
'dhcpsnooping'."
REVISION "200401150000Z"
DESCRIPTION
"Updated workgroup for new hardware:
wsc2948ggetxsysID
Updated chassisSysType for new hardware:
wsc2948ggetx
Updated chassisPs1Type for new hardware:
w156
Updated moduleType for new hardwares:
wsx4148lxmt, wsx4548gbrj45, wsx4548gbrj45v
wsx4248rj21v, wsx4302gb, wsx4248rj45v, wsx6748getx,
wsx670410ge, wsx6724sfp and wsx6148x2rj45
Updated moduleSubType2 for new hardwares:
wsf6kmsfc, wsf6kmsfc2, wsf6kmsfc2a,
wsf6kFe48af, wsf6kGe48af and wsf6kFe48x2af,
Updated moduleType for new hardwares:
e1000BaseUnknown and e10GBaseUnknown.
Modified syslogMessageFacility to include 'callhome'.
Modified sysErrDisableTimeoutEnable to include
'arpInspectionRate' and 'noStaticInlinePwr'.
Modified Description clause for deprecated objects:
sysIpAddr, sysNetMask, sysBroadcast, sysReset,
sysConsolePrimaryLoginAuthentication,
sysConsolePrimaryEnableAuthentication,
sysTelnetPrimaryLoginAuthentication,
sysTelnetPrimaryEnableAuthentication,
sysPortFastBpduGuard, chassisSerialNumber,
chassisComponentTable, moduleSerialNumber,
moduleHwHiVersion, moduleHwLoVersion,
moduleFwHiVersion, moduleFwLoVersion,
moduleSwHiVersion, moduleSwLoVersion,
portSpantreeFastStart, monitorGrp and
vlanSpantreeEnable.
Added new conformance Groups:
systemMiscGroup1,
systemTrapGroup1,
optionalSystemMiscGroup6,
optionalChassisGroup1,
portGroup4,
vlanGroup2,
ipPermitGroup2 and
optionalPortGroup1."
REVISION "200305290000Z"
DESCRIPTION
"Change the ORGANIZATION clause. Deprecated
sysClearMacTime object."
REVISION
"200305050000Z"
DESCRIPTION
"Add support of the following objects: cisco7613sysID,
wsc6509nebasysID. ChassisType: wsc4507, wsc6509NEBA,
wsc65509, cisco7613. chassisPs1Type: pwr950dc,
pwr1900ac, pwr1900dc, wscac3000w,
pwrc451400dcp, wscdc3000w, pwr1400ac.
chassisPs2Type: pwr950dc, pwr1900ac, pwr1900dc,
wscac3000w, wscdc3000w, pwr1400ac.
moduleTable: wsSvcIdsm2, wsSvcFwm1, wsSvcCe1,
wssvcSsl1, osm2oc12PosMMPlus, osm2oc12PosSIPlus,
osm16oc3PosSIPlus, osm1oc48PosSSPlus,osm1oc48PosSIPlus,
osm1oc48PosSLPlus, osm4oc3PosSIPlus, osm8oc3PosSIPlus,
osm4oc12PosSIPlus, wsx6548getx, wssup720, wssup720base.
moduleSubType: wsf6kpfc2a, wsf6kdfca, vsp300dfc,
wsf6kpfc3a, wsf6kdfc3a. moduleSubType2: wsg6489,
wsg6485, wsu4502gb, wssvcidsupg, wssup720.
portType: e100BaseLX.
Deprecate the following objects: sysIpAddr, sysNetMask,
sysBroadcast, sysTrapReceiverTable, sysReset,
sysClearPortTime, sysClearMacTime,
sysPortFastBpduGuard, chassisComponentTable,
portSpantreeFastStart, vlanTable, portChannelTable.
Remove the TC MacAddressType, and replaced other uses
by MacAddress."
REVISION
"200209240000Z"
DESCRIPTION
"Added more HW models."
REVISION
"200106110000Z"
DESCRIPTION
"Added cat6000 new HW chassis & modules."
REVISION
"200104110000Z"
DESCRIPTION
"Added more HW modules;
Added the following MIB objects under systemGrp:
sysMaxRmonMemory
sysMacReductionAdminEnable
sysMacReductionOperEnable
Added the following MIB object under fileCopyGrp:
fileCopyRuntimeConfigPart
Added the following MIB object under filterPortTable:
filterPortSuppressionOption
Added the following MIB object under syslogGrp:
syslogTelnetEnable"
REVISION
"200010100000Z"
DESCRIPTION
"Added more HW modules;
Added the following objects in systemGrp
sshPublicKeySize
Added the vlanTrunkMappingTable in vlanGrp
Added portJumboFrameGrp
Added the following objects in portCpbTable:
portCpbCosRewrite
portCpbTosRewrite
portCpbCopsGrouping
Added copyTechReportFromRuntimeToHost in fileCopyAction
Added ssh(2) in ipPermitAccessType &
ipPermitDeniedAccess."
REVISION
"200005160000Z"
DESCRIPTION
"Added more HW models;
Added the following objects:
portInlinePowerDetect
vlanPortAuxiliaryVlan
portCpbInlinePower
portCpbAuxiliaryVlan
moduleAdditionalStatus
sysExtendedRmonNetflowModuleMask
Added the voiceGrp
Added the switchAccelerationGrp"
REVISION
"200002020000Z"
DESCRIPTION
"Added the following objects:
sysPortFastBpduGuard
sysErrDisableTimeoutEnable
sysErrDisableTimeoutInterval
sysTrafficMonitorHighWaterMark
chassisPs3Type
chassisPs3Status
chassisPs3TestResult
chassisPEMInstalled
moduleEntPhysicalIndex
portAdditionalOperStatus
portEntPhysicalIndex
filterPortBroadcastThresholdFraction
mcastEnableRgmp
portCpbSpan.
modified ipPermitGrp for supporting IP Permit
Enhancement. Added more HW models."
REVISION
"9909300000Z"
DESCRIPTION
"Added more HW models."
REVISION
"9903260000Z"
DESCRIPTION
"Added traceRouteGrp."
REVISION
"9902120000Z"
DESCRIPTION
"Initial v2 version of this MIB module."
::= { workgroup 1 }
adapterCard OBJECT IDENTIFIER ::= { workgroup 2 }
wsc1000sysID OBJECT IDENTIFIER ::= { workgroup 3 }
wsc1100sysID OBJECT IDENTIFIER ::= { workgroup 4 }
wsc1200sysID OBJECT IDENTIFIER ::= { workgroup 5 }
wsc1400sysID OBJECT IDENTIFIER ::= { workgroup 6 }
wsc5000sysID OBJECT IDENTIFIER ::= { workgroup 7 }
wsc1600sysID OBJECT IDENTIFIER ::= { workgroup 8 }
cpw1600sysID OBJECT IDENTIFIER ::= { workgroup 9 }
wsc3000sysID OBJECT IDENTIFIER ::= { workgroup 10 }
-- rhino OBJECT IDENTIFIER ::= { workgroup 11 }
wsc2900sysID OBJECT IDENTIFIER ::= { workgroup 12 }
cpw2200sysID OBJECT IDENTIFIER ::= { workgroup 13 }
esStack OBJECT IDENTIFIER ::= { workgroup 14 }
wsc3200sysID OBJECT IDENTIFIER ::= { workgroup 15 }
cpw1900sysID OBJECT IDENTIFIER ::= { workgroup 16 }
wsc5500sysID OBJECT IDENTIFIER ::= { workgroup 17 }
wsc1900sysID OBJECT IDENTIFIER ::= { workgroup 18 }
cpw1220sysID OBJECT IDENTIFIER ::= { workgroup 19 }
wsc2820sysID OBJECT IDENTIFIER ::= { workgroup 20 }
cpw1420sysID OBJECT IDENTIFIER ::= { workgroup 21 }
dcd OBJECT IDENTIFIER ::= { workgroup 22 }
wsc3100sysID OBJECT IDENTIFIER ::= { workgroup 23 }
cpw1800sysID OBJECT IDENTIFIER ::= { workgroup 24 }
cpw1601sysID OBJECT IDENTIFIER ::= { workgroup 25 }
wsc3001sysID OBJECT IDENTIFIER ::= { workgroup 26 }
cpw1220csysID OBJECT IDENTIFIER ::= { workgroup 27 }
wsc1900csysID OBJECT IDENTIFIER ::= { workgroup 28 }
wsc5002sysID OBJECT IDENTIFIER ::= { workgroup 29 }
cpw1220isysID OBJECT IDENTIFIER ::= { workgroup 30 }
wsc1900isysID OBJECT IDENTIFIER ::= { workgroup 31 }
tsStack OBJECT IDENTIFIER ::= { workgroup 32 }
wsc3900sysID OBJECT IDENTIFIER ::= { workgroup 33 }
wsc5505sysID OBJECT IDENTIFIER ::= { workgroup 34 }
wsc2926sysID OBJECT IDENTIFIER ::= { workgroup 35 }
wsc5509sysID OBJECT IDENTIFIER ::= { workgroup 36 }
wsc3920sysID OBJECT IDENTIFIER ::= { workgroup 37 }
wsc6006sysID OBJECT IDENTIFIER ::= { workgroup 38 }
wsc6009sysID OBJECT IDENTIFIER ::= { workgroup 39 }
wsc4003sysID OBJECT IDENTIFIER ::= { workgroup 40 }
wsc4912gsysID OBJECT IDENTIFIER ::= { workgroup 41 }
wsc2948gsysID OBJECT IDENTIFIER ::= { workgroup 42 }
wsc6509sysID OBJECT IDENTIFIER ::= { workgroup 44 }
wsc6506sysID OBJECT IDENTIFIER ::= { workgroup 45 }
wsc4006sysID OBJECT IDENTIFIER ::= { workgroup 46 }
wsc6509nebsysID OBJECT IDENTIFIER ::= { workgroup 47 }
wsc6knamsysID OBJECT IDENTIFIER ::= { workgroup 48 }
wsc2980gsysID OBJECT IDENTIFIER ::= { workgroup 49 }
wsc6513sysID OBJECT IDENTIFIER ::= { workgroup 50 }
wsc2980gasysID OBJECT IDENTIFIER ::= { workgroup 51 }
cisco7603sysID OBJECT IDENTIFIER ::= { workgroup 53 }
cisco7606sysID OBJECT IDENTIFIER ::= { workgroup 54 }
cisco7609sysID OBJECT IDENTIFIER ::= { workgroup 55 }
wsc6503sysID OBJECT IDENTIFIER ::= { workgroup 56 }
wsc4503sysID OBJECT IDENTIFIER ::= { workgroup 58 }
wsc4506sysID OBJECT IDENTIFIER ::= { workgroup 59 }
cisco7613sysID OBJECT IDENTIFIER ::= { workgroup 60 }
wsc6509nebasysID OBJECT IDENTIFIER ::= { workgroup 61 }
wsc2948ggetxsysID OBJECT IDENTIFIER ::= { workgroup 62 }
cisco7604sysID OBJECT IDENTIFIER ::= { workgroup 63 }
wsc6504esysID OBJECT IDENTIFIER ::= { workgroup 64 }
wsc1900LiteFxsysID OBJECT IDENTIFIER ::= { workgroup 175 }
-- stackMIBobjects
systemGrp OBJECT IDENTIFIER ::= { ciscoStackMIB 1 }
chassisGrp OBJECT IDENTIFIER ::= { ciscoStackMIB 2 }
moduleGrp OBJECT IDENTIFIER ::= { ciscoStackMIB 3 }
portGrp OBJECT IDENTIFIER ::= { ciscoStackMIB 4 }
tftpGrp OBJECT IDENTIFIER ::= { ciscoStackMIB 5 }
brouterGrp OBJECT IDENTIFIER ::= { ciscoStackMIB 6 }
filterGrp OBJECT IDENTIFIER ::= { ciscoStackMIB 7 }
monitorGrp OBJECT IDENTIFIER ::= { ciscoStackMIB 8 }
vlanGrp OBJECT IDENTIFIER ::= { ciscoStackMIB 9 }
securityGrp OBJECT IDENTIFIER ::= { ciscoStackMIB 10 }
tokenRingGrp OBJECT IDENTIFIER ::= { ciscoStackMIB 11 }
multicastGrp OBJECT IDENTIFIER ::= { ciscoStackMIB 12 }
dnsGrp OBJECT IDENTIFIER ::= { ciscoStackMIB 13 }
syslogGrp OBJECT IDENTIFIER ::= { ciscoStackMIB 14 }
ntpGrp OBJECT IDENTIFIER ::= { ciscoStackMIB 15 }
tacacsGrp OBJECT IDENTIFIER ::= { ciscoStackMIB 16 }
ipPermitListGrp OBJECT IDENTIFIER ::= { ciscoStackMIB 17 }
portChannelGrp OBJECT IDENTIFIER ::= { ciscoStackMIB 18 }
portCpbGrp OBJECT IDENTIFIER ::= { ciscoStackMIB 19 }
portTopNGrp OBJECT IDENTIFIER ::= { ciscoStackMIB 20 }
mdgGrp OBJECT IDENTIFIER ::= { ciscoStackMIB 21 }
radiusGrp OBJECT IDENTIFIER ::= { ciscoStackMIB 22 }
traceRouteGrp OBJECT IDENTIFIER ::= { ciscoStackMIB 24 }
fileCopyGrp OBJECT IDENTIFIER ::= { ciscoStackMIB 25 }
voiceGrp OBJECT IDENTIFIER ::= { ciscoStackMIB 26 }
portJumboFrameGrp OBJECT IDENTIFIER ::= { ciscoStackMIB 27 }
switchAccelerationGrp OBJECT IDENTIFIER ::= { ciscoStackMIB 28 }
configGrp OBJECT IDENTIFIER ::= { ciscoStackMIB 29 }
-- textual conventions
-- The vendor ID portion of a MacAddress (first 3 octets
-- of the 6-octet MAC address)
VendorIdType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "Vendor ID Type"
SYNTAX OCTET STRING (SIZE (3))
-- the system group
-- Implementation of the system group is current for all Cisco Workgroup
-- Stack products.
sysMgmtType OBJECT-TYPE
SYNTAX INTEGER {
other(1), -- none of the following
snmpV1(2), -- Simple Network Management Protocol
smux(3), -- SNMP MUX sub-agent
snmpV2V1(4), -- Bi-lingual SNMP, Ver 2 and 1
snmpV2cV1(5),-- Bi-lingual SNMP, V2c and V1
snmpV3V2cV1(6) -- SNMPv3, SNMPv2c and SNMPv1
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Type of network management running on this
entity."
::= { systemGrp 1 }
sysIpAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION "This entity's IP address.
This object is deprecated and replaced by
ciiIPAddressType and ciiIPAddress in
CISCO-IP-IF-MIB."
::= { systemGrp 2 }
sysNetMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION "This entity's subnet mask.
This object is deprecated and replaced by
ciiIPAddressPrefixLength in CISCO-IP-IF-MIB."
::= { systemGrp 3 }
sysBroadcast OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION "This entity's broadcast address.
This object is deprecated and replaced by
ciiIPAddressBroadcast in CISCO-IP-IF-MIB."
::= { systemGrp 4 }
-- the trap receiver table
sysTrapReceiverTable OBJECT-TYPE
SYNTAX SEQUENCE OF SysTrapReceiverEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION "The trap receiver table (0 to 20 entries). This
table lists the addresses of Network Management
Stations that should receive trap messages from
this entity when an exception condition occurs.
This table is deprecated and replaced by
trapDestTable and other tables in SNMP-TARGET-
MIB and SNMP-NOTIFICATION-MIB."
::= { systemGrp 5 }
sysTrapReceiverEntry OBJECT-TYPE
SYNTAX SysTrapReceiverEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION "A trap receiver table entry."
INDEX { sysTrapReceiverAddr }
::= { sysTrapReceiverTable 1 }
SysTrapReceiverEntry ::=
SEQUENCE {
sysTrapReceiverType
INTEGER,
sysTrapReceiverAddr
IpAddress,
sysTrapReceiverComm
DisplayString
}
sysTrapReceiverType OBJECT-TYPE
SYNTAX INTEGER {
valid(1), -- add this entry
invalid(2) -- remove this entry
}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION "Setting this object to invalid(2) removes the
corresponding entry from the sysTrapReceiverTable.
To add a new entry to the sysTrapReceiverTable,
set this object to valid(1) for an IpAddress which
is not already in the table."
::= { sysTrapReceiverEntry 1 }
sysTrapReceiverAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "IP address for trap receiver."
::= { sysTrapReceiverEntry 2 }
sysTrapReceiverComm OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION "Community string used for trap messages to this
trap receiver."
::= { sysTrapReceiverEntry 3 }
-- the community table
-- This table is deprecated and replaced by the sysCommunityRo,
-- sysCommunityRw, and sysCommunityRwa objects. New workgroup products
-- will not support this table. Older products will continue to support
-- this table for some time in order to be backwards compatible with
-- existing network management applications. When this table does exist,
-- sysCommunityString.2 is the same value as sysCommunityRo,
-- sysCommunityString.3 is the same value as sysCommunityRw, and
-- sysCommunityString.4 is the same as sysCommunityRwa.
sysCommunityTable OBJECT-TYPE
SYNTAX SEQUENCE OF SysCommunityEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION "The community table (4 entries). This table lists
community strings and their access levels. When an
SNMP message is received by this entity, the
community string in the message is compared with
this table to determine access rights of the
sender.
Note that this item is only accessible when using
the community string defined in sysCommunityRwa."
::= { systemGrp 6 }
sysCommunityEntry OBJECT-TYPE
SYNTAX SysCommunityEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION "A community table entry."
INDEX { sysCommunityAccess }
::= { sysCommunityTable 1 }
SysCommunityEntry ::=
SEQUENCE {
sysCommunityAccess
INTEGER,
sysCommunityString
DisplayString
}
sysCommunityAccess OBJECT-TYPE
SYNTAX INTEGER {
other(1), -- none of the following
readOnly(2), -- read but not write all
-- but restricted items
readWrite(3), -- read and write all but
-- restricted items
readWriteAll(4) -- read and write all
}
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "A value of readWriteAll(4) allows the community
to read and write all objects in the MIB. A
value of readWrite(3) allows the community to
read and write all objects except restricted
items such as community strings, which cannot
be accessed at all. A value of readOnly(2) allows
the community to read all objects except
restricted items. A value of other(1) allows no
access."
::= { sysCommunityEntry 1 }
sysCommunityString OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION "Configurable community string with access rights
defined by the value of sysCommunityAccess."
::= { sysCommunityEntry 2 }
-- additional system group objects
sysAttachType OBJECT-TYPE
SYNTAX INTEGER {
other(1), -- none of the following
dualAttach(2), -- port 1 is A and port 2 is B
singleAttach(3),-- port 1 is S and port 2 is M
nullAttach(4), -- port 1 is M and port 2 is M
dualPrio(5) -- dual attach priority mode
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The requested concentrator attachment type. For a
dual attachment concentrator which can be
connected to the trunk ring, the first FDDI port
is configured as A and the second FDDI port is
configured as B.
For a single attachment concentrator which can be
connected beneath another concentrator, the first
FDDI port is configured as M and the second FDDI
port is configured as S. For a null attachment
concentrator which can be located at the root of
the tree, the first two FDDI ports are configured
as M.
This object does not take effect until the
concentrator is reset. The current attachment
type can be determined from snmpFddiPORTPCType
for ports 1 and 2."
DEFVAL { dualAttach }
::= { systemGrp 7 }
sysTraffic OBJECT-TYPE
SYNTAX INTEGER (0..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Traffic meter value, i.e. the percentage of
bandwidth utilization for the previous polling
interval."
::= { systemGrp 8 }
sysReset OBJECT-TYPE
SYNTAX INTEGER {
other(1), -- none of the following
reset(2), -- resetting the system
resetMinDown(3) -- reset in minimal down time
}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION "Writing reset(2) to this object resets the
control logic of all modules in the system.
Writing resetMinDown(3) to this object resets the
system with the minimal system down time. The
resetMinDown(3) is only supported in systems with
redundant supervisors.
This object is deprecated and replaced by
csyScheduledReset in CISCO-SYSTEM-MIB."
::= { systemGrp 9 }
sysBaudRate OBJECT-TYPE
SYNTAX INTEGER {
b600(600),
b1200(1200),
b2400(2400),
b4800(4800),
b9600(9600),
b19200(19200),
b38400(38400)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The baud rate in bits per second of the RS-232
port."
DEFVAL { b9600 }
::= { systemGrp 10 }
sysInsertMode OBJECT-TYPE
SYNTAX INTEGER {
other(1), -- none of the following
standard(2), -- standard insertion
scheduled(3), -- scheduled insertion
graceful(4) -- graceful insertion
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The mode for inserting M-ports into the
concentrator ring."
::= { systemGrp 11 }
sysClearMacTime OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION "The time (in hundredths of a second) since mac
counters were last cleared. Writing a 0 to this
object causes the mac counters to be cleared."
::= { systemGrp 12 }
sysClearPortTime OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION "The time (in hundredths of a second) since port
counters were last cleared. Writing a 0 to this
object causes the port counters to be cleared."
::= { systemGrp 13 }
-- the FDDI ring map table
sysFddiRingTable OBJECT-TYPE
SYNTAX SEQUENCE OF SysFddiRingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The fddi ring map table. This table lists the
nodes in the FDDI ring(s) to which the system
belongs."
::= { systemGrp 14 }
sysFddiRingEntry OBJECT-TYPE
SYNTAX SysFddiRingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A FDDI Ring table entry."
INDEX { sysFddiRingSMTIndex, sysFddiRingAddress }
::= { sysFddiRingTable 1 }
SysFddiRingEntry ::=
SEQUENCE {
sysFddiRingSMTIndex
INTEGER,
sysFddiRingAddress
MacAddress,
sysFddiRingNext
MacAddress
}
sysFddiRingSMTIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The value of the SMT index associated with this
ring."
::= { sysFddiRingEntry 1 }
sysFddiRingAddress OBJECT-TYPE
SYNTAX MacAddress -- OCTET STRING (SIZE (6))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The MAC address of this node in the FDDI ring."
::= { sysFddiRingEntry 2 }
sysFddiRingNext OBJECT-TYPE
SYNTAX MacAddress -- OCTET STRING (SIZE (6))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The MAC address of the next node in the FDDI
ring."
::= { sysFddiRingEntry 3 }
-- additional system group objects
sysEnableModem OBJECT-TYPE
SYNTAX INTEGER { enabled(1), disabled(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Indicates whether the RS-232 port modem control
lines are enabled."
DEFVAL { disabled }
::= { systemGrp 15 }
sysEnableRedirects OBJECT-TYPE
SYNTAX INTEGER { enabled(1), disabled(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Indicates whether ICMP redirect messages are sent
or received by the system."
DEFVAL { enabled }
::= { systemGrp 16 }
sysEnableRmon OBJECT-TYPE
SYNTAX INTEGER { enabled(1), disabled(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Indicates whether the SNMP agent supports the
RMON MIB."
DEFVAL { enabled }
::= { systemGrp 17 }
sysArpAgingTime OBJECT-TYPE
SYNTAX INTEGER (0..1000000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The aging time for the ARP table."
DEFVAL { 1200 }
::= { systemGrp 18 }
sysTrafficPeak OBJECT-TYPE
SYNTAX INTEGER (0..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Peak traffic meter value since the last time port
counters were cleared or the system started (see
sysClearPortTime)."
::= { systemGrp 19 }
sysTrafficPeakTime OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The time (in hundredths of a second) since the
peak traffic meter value occurred."
::= { systemGrp 20 }
sysCommunityRwa OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "When an SNMP message is received by this entity,
the community string in the message is compared
with this string first. If it matches, read-write
access is granted to all items in the MIB. If it
doesn't match, the sysCommunityRw string is
compared next.
Note that this item is only accessible when using
the community string defined in sysCommunityRwa."
::= { systemGrp 21 }
sysCommunityRw OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "When an SNMP message is received by this entity,
the community string in the message is compared
with this string second. If it matches, read-write
access is granted to all items in the MIB except
restricted items such as community strings.
(Restricted items appear empty when read and
return a no such name error when an attempt is
made to write them.) If it doesn't match, the
sysCommunityRo string is compared next.
Note that this item is only accessible when using
the community string defined in sysCommunityRwa."
::= { systemGrp 22 }
sysCommunityRo OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "When an SNMP message is received by this entity,
the community string in the message is compared
with this string third. If it matches, read-only
access is granted to all items in the MIB except
restricted items such as community strings.
(Restricted items appear empty when read.) If it
doesn't match, no access is granted, no response
is sent back to the SNMP requester, and an SNMP
is sent to the SNMP trap receivers if configured.
Note that this item is only accessible when using
the community string defined in sysCommunityRwa."
::= { systemGrp 23 }
sysEnableChassisTraps OBJECT-TYPE
SYNTAX INTEGER { enabled(1), disabled(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Indicates whether chassisAlarmOn and
chassisAlarmOff traps in this MIB should be
generated."
DEFVAL { disabled }
::= { systemGrp 24 }
sysEnableModuleTraps OBJECT-TYPE
SYNTAX INTEGER { enabled(1), disabled(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Indicates whether moduleUp and moduleDown traps
in this MIB should be generated."
DEFVAL { disabled }
::= { systemGrp 25 }
sysEnableBridgeTraps OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2),
enabledForNewRootOnly(3), -- read-only
enabledForTopoChangeOnly(4) -- read-only
}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION "Indicates whether newRoot and topologyChange
traps in the BRIDGE-MIB (RFC 1493) should be
generated.
enabled -- both newRoot and topologyChange
traps are enabled.
disabled -- both of the newRoot and
topologyChange traps are disabled.
enabledForNewRootOnly -- only the newRoot trap is
enabled. This value is read-only.
enabledForTopoChangeOnly -- only the
topologyChange trap is enabled. This
value is read-only.
This object is deprecated and replaced by
stpxNotificationEnable in
CISCO-STP-EXTENSIONS-MIB."
DEFVAL { disabled }
::= { systemGrp 26 }
sysIpVlan OBJECT-TYPE
SYNTAX VlanIndex
MAX-ACCESS read-write
STATUS current
DESCRIPTION "This entity's IP address Virtual LAN
association."
DEFVAL { 1 }
::= { systemGrp 27 }
sysConfigChangeTime OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The time (in hundredths of a second) since the
configuration of the system was last changed."
::= { systemGrp 28 }
sysEnableRepeaterTraps OBJECT-TYPE
SYNTAX INTEGER { enabled(1), disabled(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Indicates whether the traps in the REPEATER-MIB
(RFC1516) should be generated."
DEFVAL { disabled }
::= { systemGrp 29 }
sysBannerMotd OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Message of the day banner which is displayed on
the Command Line Interface before log in."
::= { systemGrp 30 }
sysEnableIpPermitTraps OBJECT-TYPE
SYNTAX INTEGER { enabled(1), disabled(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Indicates whether the IP permit traps in this MIB
should be generated."
DEFVAL { disabled }
::= { systemGrp 31 }
-- the system traffic meter table
sysTrafficMeterTable OBJECT-TYPE
SYNTAX SEQUENCE OF SysTrafficMeterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The system traffic meter table. This table
lists the traffic meters available in the
system."
::= { systemGrp 32 }
sysTrafficMeterEntry OBJECT-TYPE
SYNTAX SysTrafficMeterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A traffic meter table entry."
INDEX { sysTrafficMeterType}
::= { sysTrafficMeterTable 1 }
SysTrafficMeterEntry ::=
SEQUENCE {
sysTrafficMeterType
INTEGER,
sysTrafficMeter
INTEGER,
sysTrafficMeterPeak
INTEGER,
sysTrafficMeterPeakTime
TimeTicks
}
sysTrafficMeterType OBJECT-TYPE
SYNTAX INTEGER {
systemSwitchingBus(1), -- system switching bus
-- for WS-X5530 supervisor module
switchingBusA(2), -- switching bus A
switchingBusB(3), -- switching bus B
switchingBusC(4) -- switching bus C
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The type of traffic meter."
::= { sysTrafficMeterEntry 1 }
sysTrafficMeter OBJECT-TYPE
SYNTAX INTEGER (0..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Traffic meter value, i.e. the percentage of
bandwidth utilization for the previous polling
interval."
::= { sysTrafficMeterEntry 2 }
sysTrafficMeterPeak OBJECT-TYPE
SYNTAX INTEGER (0..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Peak traffic meter value since the system
started."
::= { sysTrafficMeterEntry 3 }
sysTrafficMeterPeakTime OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The time (in hundredths of a second) since the
peak traffic meter value occurred."
::= { sysTrafficMeterEntry 4 }
sysEnableVmpsTraps OBJECT-TYPE
SYNTAX INTEGER { enabled(1), disabled(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Indicates whether the vmVmpsChange trap defined
in CISCO-VLAN-MEMBERSHIP-MIB should be generated."
DEFVAL { disabled }
::= { systemGrp 33}
sysConfigChangeInfo OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates which NVRAM block is changed by whom."
::= { systemGrp 34 }
sysEnableConfigTraps OBJECT-TYPE
SYNTAX INTEGER { enabled(1), disabled(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Indicates whether sysConfigChange trap in this
MIB should be generated."
DEFVAL { disabled }
::= { systemGrp 35 }
sysConfigRegister OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (2))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The value of configuration register that will be
used by the supervisor module when the system is
restarted.
This MIB object is only supported in systems with
supervisor modules having ROMMON support.
The lowest four bits of the configuration register
(bits 3,2,1, and 0) form the boot field and the
boot field determines whether the system boots
from as the following:
0000 -- stay in ROM monitor
0001 -- boot from the first bootable system
images on the bootflash
0010 to 1111
-- boot from the first bootable system
images specified in the sysBootVariable
The bit 5(0x0020) indicates whether the
configuration file specified in
sysStartupConfigSourceFile will beused recurringly
or not whenever the system resets. If this bit is
not set, the configuration file(s) specified in
sysStartupConfigSourceFile will only be used once
and the value of sysStartupConfigSourceFile will
be reset to empty string automatically during the
next system reset.
If the bit 6(0x0040) is set, the system will start
with default configuration.
The bits 11,12 (0x0800, 0x1000) are used to
specify the console line speed in ROM monitor mode
as the following:
00 -- 9600
01 -- 1200
10 -- 4800
11 -- 2400
The unspecified bits are not used."
DEFVAL { '010f'h } -- "01 0F"
::= { systemGrp 36 }
sysBootVariable OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "A list of the system boot images in the BOOT
environment variable on supervisor modules with
ROMMON. The format of sysBootVariable should be:
<device>:[<fileName>],1;{<device>:[<fileName>],1;...}
If the [fileName] is not specified, the first file
on the <device> will be used.
This MIB object is only supported in systems
having supervisor modules with ROMMON."
-- DEFVAL { "bootflash:" }
::= { systemGrp 37 }
sysBootedImage OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The name of the system boot image which the
system booted from.
This MIB object is only supported in the system
with Supervisor module 3 present."
::= { systemGrp 38 }
sysEnableEntityTrap OBJECT-TYPE
SYNTAX INTEGER { enabled(1), disabled(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Indicates whether entConfigChange trap in the
ENTITY-MIB should be generated."
DEFVAL { disabled }
::= { systemGrp 39 }
sysEnableStpxTrap OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2),
enabledForInconOnly(3), -- read-only
enabledForRootOnly(4), -- read-only
enabledForLoopOnly(5), -- read-only
enabledForInconRootOnly(6), -- read-only
enabledForInconLoopOnly(7), -- read-only
enabledForRootLoopOnly(8) -- read-only
}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION "Indicates whether stpxInconsistencyUpdate,
stpxRootInconsistencyUpdate and
stpxLoopInconsistencyUpdate notifications in
CISCO-STP-EXTENSIONS-MIB should be generated.
enabled -- the stpxInconsistencyUpdate,
stpxRootInconsistencyUpdate and
stpxLoopInconsistencyUpdate traps are
all enabled.
disabled -- the stpxInconsistencyUpdate,
stpxRootInconsistencyUpdate and
stpxLoopInconsistencyUpdate traps
are all disabled.
enabledForInconOnly -- only the
stpxInconsistencyUpdate trap is
enabled. This value is read-only.
enabledForRootOnly -- only the
stpxRootInconsistencyUpdate trap is
enabled. This value is read-only.
enabledForLoopOnly -- only the
stpxLoopInconsistencyUpdate trap is
enabled. This value is read-only.
enabledForInconRootOnly -- only the
stpxInconsistencyUpdate and
stpxRootInconsistencyUpdate traps are
enabled. This value is read-only.
enabledForInconLoopOnly -- only the
stpxInconsistencyUpdate and
stpxLoopInconsistencyUpdate traps are
enabled. This value is read-only.
enabledForRootLoopOnly -- only the
stpxRootInconsistencyUpdate and
stpxLoopInconsistencyUpdate traps are
enabled. This value is read-only.
This object is deprecated and replaced by
stpxNotificationEnable in
CISCO-STP-EXTENSIONS-MIB."
DEFVAL { disabled }
::= { systemGrp 40 }
sysExtendedRmonVlanModeEnable OBJECT-TYPE
SYNTAX INTEGER { enabled(1), disabled(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Indicates whether the Extended RMON VlanMode
feature is enabled or not. If it is set to
enabled(1), hostTable (rmon 4) will provide the
information of a list of VLANs instead of a list
of MAC addresses for a monitored trunking port."
DEFVAL { disabled }
::= { systemGrp 41 }
sysExtendedRmonNetflowPassword OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The password for enabling the Extended RMON
Netflow feature and this object has to be set
before setting sysExtendedRmonNetflowEnable to
enabled(1). When reading this object, it will
return empty string.
If the platform supports
sysExtendedRmonNetflowModuleMask object, this
object will be not be supported."
::= { systemGrp 42 }
sysExtendedRmonNetflowEnable OBJECT-TYPE
SYNTAX INTEGER { enabled(1), disabled(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Indicates whether the Extended RMON Netflow
feature is enabled or not. Setting this object to
disabled(2), will clear
sysExtendedRmonNetflowPassword automatically.
Setting this object to enabled(1) will be rejected
if sysExtendedRmonNetflowPassword does not contain
a valid password.
If the platform supports
sysExtendedRmonNetflowModuleMask object, this
object will not be supported."
DEFVAL { disabled }
::= { systemGrp 43 }
sysExtendedRmonVlanAgentEnable OBJECT-TYPE
SYNTAX INTEGER { enabled(1), disabled(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Indicates whether the Extended RMON VlanAgent
feature is enabled or not. If it is set to
enabled(1), the extended RMON will also provide
the information on VLAN based interface in
addition to the port based interface for the
monitored traffic.
Setting this object to enabled(1), it will consume
more CPU for processing each monitored frame and
affect Extended RMON performance."
DEFVAL { disabled }
::= { systemGrp 44 }
sysExtendedRmonEnable OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2),
noNAMPresent(3) -- No Network Analysis Module
-- present
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Indicates whether the SNMP agent supports the
extended RMON feature. noNAMPresent(3) is a
read-only value and the agent will return this
value when the sysEnableExtendedRmon is set to
enabled(1), but Network Analysis module is not
present in the system."
DEFVAL { enabled }
::= { systemGrp 45 }
sysConsolePrimaryLoginAuthentication OBJECT-TYPE
SYNTAX INTEGER{ tacacs(1),
radius(2),
local(3) -- read-only
}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION "Indicates whether TACACS+ or RADIUS is the
primary login authentication, i.e which method
will be tried first for a console session. If
tacacsLoginAuthentication and
radiusLoginAuthentication are set to disabled
then sysConsolePrimaryLoginAuthentication will
have a value of local(3).
This object is deprecated and replaced by
cacPriorityTable in CISCO-AAA-CLIENT-MIB."
::= { systemGrp 46 }
sysConsolePrimaryEnableAuthentication OBJECT-TYPE
SYNTAX INTEGER{ tacacs(1),
radius(2),
local(3) -- read-only
}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION "Indicates whether TACACS+ or RADIUS is the
primary enable authentication, i.e which method
will be tried first for a console session. If
tacacsEnableAuthentication and
radiusEnableAuthentication are set to disabled
then sysConsolePrimaryEnableAuthentication will
have a value of local(3).
This object is deprecated and replaced by
cacPriorityTable in CISCO-AAA-CLIENT-MIB."
::= { systemGrp 47 }
sysTelnetPrimaryLoginAuthentication OBJECT-TYPE
SYNTAX INTEGER{ tacacs(1),
radius(2),
local(3) -- read-only
}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION "Indicates whether TACACS+ or RADIUS is the
primary login authentication, i.e which method
will be tried first for a telnet session. If
tacacsLoginAuthentication and
radiusLoginAuthentication are set to disabled then
sysTelnetPrimaryLoginAuthentication will have a
value of local(3).
This object is deprecated and replaced by
cacPriorityTable in CISCO-AAA-CLIENT-MIB."
::= { systemGrp 48 }
sysTelnetPrimaryEnableAuthentication OBJECT-TYPE
SYNTAX INTEGER{ tacacs(1),
radius(2),
local(3) -- read-only
}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION "Indicates whether TACACS+ or RADIUS is the
primary enable authentication, i.e which method
will be tried first for a telnet session. If
tacacsEnableAuthentication and
radiusEnableAuthentication are set to disabled
then sysTelnetPrimaryEnableAuthentication will
have a value of local(3).
This object is deprecated and replaced by
cacPriorityTable in CISCO-AAA-CLIENT-MIB."
::= { systemGrp 49 }
sysStartupConfigSource OBJECT-TYPE
SYNTAX INTEGER{ flashFileRecurring(1),
flashFileNonRecurring(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Indicates whether the configuration file(s)
specified in sysStartupConfigSourceFile will be
used recurringly or not whenever the system
resets.
Setting this object to flashFileNonRecurring(2),
the configuration file(s) specified in
sysStartupConfigSourceFile will only be used once
and the value of sysStartupConfigSourceFile will
be reset to empty string automatically during the
next system reset.
This MIB object is only supported in systems with
SupG supervisor models or supervisor models that
have flash file system support."
::= { systemGrp 50 }
sysStartupConfigSourceFile OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Indicates which configuration file(s) on the
flash device will be used during the next system
startup.
If the value of this MIB object contains one or
multiple valid configuration file(s), then the
valid configuration file(s) will reconfigure the
system during the next system startup one by one
in the order specified. If the value of this MIB
object does not contain the valid configuration
file(s) on the device, the NVRAM configuration
will be used instead.
For supervisor models wsx5540 and wsx5550, only
'cfg1' and 'cfg2' are valid file names.
For supervisor models with the flash file system
support, the valid file name has the format of
'<device:><file>[;<device:><file>...]'.
This MIB object is only supported in systems with
supervisor models wsx5540 and wsx5550 or
supervisor models with the flash file system
support."
::= { systemGrp 51 }
sysConfigSupervisorModuleNo OBJECT-TYPE
SYNTAX INTEGER (1..16)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Indicates the supervisor module (active or
standby, if applicable) that the MIB objects
sysConfigRegister, sysBootVariable,
sysStartupConfigSource, and
sysStartupConfigSourceFile are specified for.
This MIB object is only supported by the
supervisor modules with the flash file system
feature support. The default value for this MIB
object is set to the active supervisor module
number."
::= { systemGrp 52 }
sysStandbyPortEnable OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Indicates whether the standby port feature is
enabled or not. If this object is set to
enabled(1), the uplink ports on the standby
supervisor module are activated; otherwise, the
uplink ports on the standby supervisor remain
inactive."
DEFVAL {disabled }
::= { systemGrp 53 }
sysPortFastBpduGuard OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION "Indicates whether BPDU Guard for Spanning Tree
Port Fast Start feature is enabled or not. If the
value of this object is set to enabled(1), then
when the switch receives a BPDU from a port with
the value of portSpantreeFastStart object set to
enabled(1), that port is immediately disabled.
This object is deprecated and replaced by
stpxFastStartBpduGuardEnable in
CISCO-STP-EXTENSIONS-MIB."
DEFVAL { disabled }
::= { systemGrp 54 }
sysErrDisableTimeoutEnable OBJECT-TYPE
SYNTAX BITS {
other(0),
udld(1),
duplexMismatch(2),
bpduPortGuard(3),
channelMisconfig(4),
crossBarFallBack(5),
gl2ptIngressLoop(6),
gl2ptThresholdExceed(7),
bcastSuppression(8),
arpInspectionRate(9),
noStaticInlinePwr(10),
camMonitor(11),
gl2ptCdpThresholdExceed(12),
gl2ptStpThresholdExceed(13),
gl2ptVtpThresholdExceed(14),
linkRxCrc(15),
linkTxCrc(16),
linkInErrors(17),
packetBufferError(18),
ethernetOam(19),
gl2ptEoamThresholdExceed(20)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Indicates whether errdisable timeout feature is
enabled for each of the causes or not. The
other(0) is for all causes other than:
udld(1),
duplexMismatch(2),
bpduPortGuard(3),
channelMisconfig(4),
crossBarFallBack(5), (only supported on platforms
that support this errdisable
reason.)
gl2ptIngressLoop(6), (only supported on platforms
that support this errdisable
reason.)
gl2ptThresholdExceed(7), (only supported on
platforms that support this
errdisable reason.)
bcastSuppression(8), (only supported on platforms
that support this errdisable
reason.)
arpInspectionRate(9), (only supported on platforms
that support this errdisable
reason.)
noStaticInlinePwr(10), (only supported on
platforms that support this
errdisable reason.)
camMonitor(11), (only supported on
platforms that support this
errdisable reason.)
gl2ptCdpThresholdExceed(12), (only supported on
platforms that support this
errdisable reason.)
gl2ptStpThresholdExceed(13), (only supported on
platforms that support this
errdisable reason.)
gl2ptVtpThresholdExceed(14), (only supported on
platforms that support this
errdisable reason.)
linkRxCrc(15), (only supported on
platforms that support this
errdisable reason.)
linkTxCrc(16), (only supported on
platforms that support this
errdisable reason.)
linkInErrors(17), (only supported on
platforms that support this
errdisable reason.)
packetBufferError(18), (only supported on
platforms that support this
errdisable reason.)
ethernetOam(19), (only supported on
platforms that support this
errdisable reason.)
gl2ptEoamThresholdExceed(20), (only supported on
platforms that support this
errdisable reason.)
A port is in errdisable state if ifAdminStatus of
the port in the ifTable is up(1) while the port is
shutdown during runtime by the system due to error
detection. If the value of object
portAdditionalOperStatus for the port is
errdisable(11) then that port is in errdisable
state.
By setting the bit corresponding to a cause to
'1', this errdisable timeout feature is enabled
on the system for the ports that are put into
errdisable state by that cause, then those ports
can be re-enabled automatically during the timeout
interval as specified by
sysErrDisableTimeoutInterval object after they
are put into errdisable state by that cause;
otherwise, by setting the bit corresponding to a
cause to '0', this errdisable timeout feature is
disabled on the system for the ports that are put
into errdisable state by that cause, then those
ports will remain shutdown until the user
re-enable it manually."
DEFVAL { { } }
::= { systemGrp 55 }
sysErrDisableTimeoutInterval OBJECT-TYPE
SYNTAX INTEGER (30..86400)
UNITS "seconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Indicates the timeout interval in seconds for
errdisable timeout feature."
DEFVAL { 300 }
::= { systemGrp 56 }
sysTrafficMonitorHighWaterMark OBJECT-TYPE
SYNTAX INTEGER (0..100)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Indicates the high watermark for the switching
bus traffic in percentage. Syslog messages will be
generated if the switching bus traffic goes over
this object value during the polling interval.
Setting this object value to 100 would mean no
syslog message would be generated. For systems
with 3 switching buses, high watermark and syslog
will be for each switching bus."
DEFVAL { 100 }
::= { systemGrp 57 }
sysHighAvailabilityEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Indicates whether High System Availability
feature is enabled or not. If this feature is
enabled, the active supervisor's layer-2 protocol
state will be synched to the standby supervisor
module, thus maintaining an up-to-date protocol
data on the standby supervisor whenever possible.
This object is supported in systems with High
System Availability feature support."
DEFVAL { false }
::= { systemGrp 58 }
sysHighAvailabilityVersioningEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Indicates whether support for supervisor software
image versioning (i.e., the capability to run
different images on the active and standby
supervisors) for the High System Availability
feature is enabled or not.
This object is supported in systems with High
System Availability feature support."
DEFVAL { false }
::= { systemGrp 59 }
sysHighAvailabilityOperStatus OBJECT-TYPE
SYNTAX INTEGER {
running(1),
notRunning(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the operational status of High System
Availability feature. If the value of this object
is notRunning(2), then the reason why this feature
is actually not running is specified by the object
sysHighAvailabilityNotRunningReason. If the value
of this object is running(1), then the value of
object sysHighAvailabilityOperReason is empty
string.
This object is supported in systems with High
System Availability feature support."
::= { systemGrp 60 }
sysHighAvailabilityNotRunningReason OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the reason why High System Availability
feature is not running when the value of
sysHighAvailabilityOperStatus is notRunning(2).
The value of this object is empty string when
the value of sysHighAvailabilityOperStatus is
running(1).
This object is supported in systems with High
System Availability feature support."
::= { systemGrp 61 }
sysExtendedRmonNetflowModuleMask OBJECT-TYPE
SYNTAX BITS {
module1(0),
module2(1),
module3(2),
module4(3),
module5(4),
module6(5),
module7(6),
module8(7),
module9(8),
module10(9),
module11(10),
module12(11),
module13(12),
module14(13),
module15(14),
module16(15)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Indicates Netflow Export Data (NDE) to be sent to
which Network Analysis Modules (NAM) in the same
chassis.
If users set a bit from off to on, the system will
check the corresponding module is a NAM or not.
If it is not, the system should return error.
This mib object will only be supported by the
system that can support the multiple NAM modules."
::= { systemGrp 62 }
sshPublicKeySize OBJECT-TYPE
SYNTAX INTEGER (0 | 512..2048)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Indicates public key size in bits. In write, if
a key does not exist, a value between 512 and 2048
will generate a RSA public key with the value as
its key size for secured shell access. If a key
exists a value other than 0 is valid, indicating a
clear key operation. In read, the current key size
is returned if a key exists. If not,a 0 is
returned."
::= { systemGrp 63 }
sysMaxRmonMemory OBJECT-TYPE
SYNTAX INTEGER (0..100)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Indicates the maximum percentage of the memory
usage for RMON."
::= { systemGrp 64 }
sysMacReductionAdminEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Indicates whether Mac Reduction feature (to
reduce the number of MAC addresses used in
bridge identifier) is administratively enabled
on the device or not."
::= { systemGrp 65 }
sysMacReductionOperEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates whether Mac Reduction feature (to
reduce the number of MAC addresses used in
bridge identifier) is operationaly enabled
on the device or not.
If the value of this object is true(1), then
the accepted values for dot1dStpPriority
in BRIDGE-MIB should be multiples of 4096 plus
bridge instance ID, such as VlanIndex. Changing
this object value might cause the values of
dot1dBaseBridgeAddress and dot1dStpPriority
in BRIDGE-MIB to be changed also."
::= { systemGrp 66 }
sysStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1), -- none of the following
ok(2), -- status ok
minorFault(3), -- minor problem
majorFault(4) -- major problem
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The operational status of the system."
::= { systemGrp 67 }
-- the chassis group
-- Implementation of the chassis group is current for all Cisco
-- Workgroup Stack products.
chassisSysType OBJECT-TYPE
SYNTAX INTEGER {
other(1), -- none of the following
wsc1000(3), -- 2+8 Port CDDI Concentrator
wsc1001(4), -- 2+8 Port FDDI Concentrator
wsc1100(5), -- 2+16 Port FDDI/CDDI Concentrator
wsc5000(6), -- 5 slot Switch
wsc2900(7), -- closed 2 slot Switch
wsc5500(8), -- 13 slot Switch
wsc5002(9), -- 2 slot Switch
wsc5505(10), -- 5 slot Switch
wsc1200(11), -- 2+8 Port FDDI/Ethernet Switch
wsc1400(12), -- 2 slot FDDI/CDDI Concentrator
wsc2926(13), -- closed 2 slot Switch
wsc5509(14), -- 9 slot Switch
wsc6006(15), -- 6 slot Switch
wsc6009(16), -- 9 slot Switch
wsc4003(17), -- 3 slot Switch
wsc5500e(18),-- 13 slot Switch
wsc4912g(19), -- closed 2 slot Switch
wsc2948g(20), -- closed 2 slot Switch
wsc6509(22), -- 9 slot Switch
wsc6506(23), -- 6 slot Switch
wsc4006(24), -- 6 slot Switch
wsc6509NEB(25),-- 9 slot Verticle Chassis Switch
wsc2980g(26), -- closed 3 slot Switch
wsc6513(27), -- 13 slot Switch
wsc2980ga(28), -- closed 3 slot Switch
cisco7603(30), -- 3 slot Chassis (Nebula-SP)
cisco7606(31), -- 6 slot Chassis (Seaquest-SP)
cisco7609(32), -- 9 slot chassis
wsc6503(33), -- 3 slot Chassis
wsc6509NEBA(34), -- 9 slot Chassis
wsc4507(35), -- 7 slot Chassis (Galaxy3)
wsc4503(36), -- 3 slot Chassis (Galaxy5)
wsc4506(37), -- 6 slot Chassis (Galaxy6)
wsc65509(38), -- 9 slot Chassis
cisco7613(40), -- 13 slot Chassis
wsc2948ggetx(41), -- closed 2 slot Switch
cisco7604(42), -- 4 slot Chassis
wsc6504e(43), -- 4 slot Chassis
mec6524gs8s(45), -- closed 1 slot switch
mec6524gt8s(48), -- closed 1 slot switch
cisco7603s(52) -- 3 slot Chassis
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The chassis system type."
::= { chassisGrp 1 }
chassisBkplType OBJECT-TYPE
SYNTAX INTEGER {
other(1), -- none of the following
fddi(2), -- FDDI
fddiEthernet(3),-- FDDI and Ethernet
giga(4), -- 1.2 Gigabit switch
giga3(5), -- 3.6 Gigabit switch
giga3E(6), -- 3.6 Gigabit switch
-- enhanced
giga12(7), -- 12 Gigabit switch
giga16(8), -- 16 Gigabit switch
giga40(9) -- 40 Gigabit switch
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The chassis backplane type."
::= { chassisGrp 2 }
chassisPs1Type OBJECT-TYPE
SYNTAX INTEGER {
other(1), -- none of the following
none(2), -- no power supply
w50(3), -- 50 watt supply
w200(4), -- 200 watt supply
w600(5), -- 600 watt supply
w80(6), -- 80 watt supply
w130(7), -- 130 watt supply
wsc5008(8), -- 376 watt supply
wsc5008a(9), -- 376 watt supply w/PFC
w175(10), -- 175 watt supply
wsc5068(11), -- 376 watt supply DC
wsc5508(12), -- 1100 watt supply
wsc5568(13), -- 1200 watt supply DC
wsc5508a(14), -- 1200 watt supply
w155(15), -- 155 watt supply
w175pfc(16), -- 175 watt supply w/PFC
w175dc(17), -- 175 watt supply DC
wsc5008b(18), -- 376 watt supply
-- w/PFC, OCP
wsc5008c(19), -- 436 watt supply w/PFC
wsc5068b(20), -- 376 watt supply DC
-- w/OCP
wscac1000(21), -- 1000 watt supply AC
wscac1300(22), -- 1300 watt supply AC
wscdc1000(23), -- 1000 watt supply DC
wscdc1360(24), -- 1360 watt supply DC
wsx4008(25), -- 400 watt supply
wsc5518(26), -- 805 watt supply AC
wsc5598(27), -- 805 watt supply DC
w120(28), -- 120 watt
externalPS(29), -- external power supply
wscac2500w(30), -- 2500 watt supply AC
wscdc2500w(31), -- 2500 watt supply DC
wsx4008dc(32), -- 400 watt supply DC
wscac4000w(33), -- 4000 watt supply AC
pwr4000dc(34), -- 4000 watt supply DC
pwr950ac(35), -- 950 watt supply AC
pwr950dc(36), -- 950 watt supply DC
pwr1900ac(37), -- 1900 watt supply AC
pwr1900dc(38), -- 1900 watt supply DC
pwr1900ac6(39), -- 1900 watt supply
-- AC/6 slots
wsx4008ac650w(42), -- 650 watt supply AC
wsx4008dc650w(43), -- 650 watt supply DC
wscac3000w(44), -- 3000 watt supply AC
pwrc451000ac(46), -- 1000 watt supply AC
pwrc452800acv(47),-- 2800 watt supply AC
pwrc451300acv(48),-- 1300 watt supply AC
pwrc451400dcp(49),-- 1400 watt supply DC
wscdc3000w(50), -- 3000 watt supply DC
pwr1400ac(51), -- 1400 watt supply AC
w156(52), -- 156 watt supply AC
wscac6000w(53), -- 6000 watt supply AC
pwr2700ac(54), -- 2700 watt supply AC
pwr2700dc(55), -- 2700 watt supply DC
wscac8700we(58), -- 8700 watt supply AC
pwr2700ac4(59), -- 2700 watt supply AC
pwr2700dc4(60), -- 2700 watt supply DC
pwr400dc(63), -- 400 watt supply DC
pwr400ac(64) -- 400 watt supply AC
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Type of power supply number 1."
::= { chassisGrp 3 }
chassisPs1Status OBJECT-TYPE
SYNTAX INTEGER {
other(1), -- none of the following
ok(2), -- status ok
minorFault(3), -- minor problem
majorFault(4) -- major problem
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Status of power supply number 1. If the status is
not ok, the value of chassisPs1TestResult gives
more detailed information about the power supply's
failure condition(s)."
::= { chassisGrp 4 }
chassisPs1TestResult OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Test result for power supply number 1. A zero
indicates that the supply passed all tests. Bits
set in the result indicate error conditions."
::= { chassisGrp 5 }
chassisPs2Type OBJECT-TYPE
SYNTAX INTEGER {
other(1), -- none of the following
none(2), -- no power supply
w50(3), -- 50 watt supply
w200(4), -- 200 watt supply
w600(5), -- 600 watt supply
w80(6), -- 80 watt supply
w130(7), -- 130 watt supply
wsc5008(8), -- 376 watt supply
wsc5008a(9), -- 376 watt supply w/PFC
w175(10), -- 175 watt supply
wsc5068(11), -- 376 watt supply DC
wsc5508(12), -- 1100 watt supply
wsc5568(13), -- 1200 watt supply DC
wsc5508a(14), -- 1200 watt supply
w155(15), -- 155 watt supply
w175pfc(16), -- 175 watt supply w/PFC
w175dc(17), -- 175 watt supply DC
wsc5008b(18), -- 376 watt supply
-- w/PFC, OCP
wsc5008c(19), -- 436 watt supply w/PFC
wsc5068b(20), -- 376 watt supply DC
-- w/OCP
wscac1000(21), -- 1000 watt supply AC
wscac1300(22), -- 1300 watt supply AC
wscdc1000(23), -- 1000 watt supply DC
wscdc1360(24), -- 1360 watt supply DC
wsx4008(25), -- 400 watt supply
wsc5518(26), -- 805 watt supply AC
wsc5598(27), -- 805 watt supply DC
w120(28), -- 120 watt
externalPS(29), -- external power supply
wscac2500w(30), -- 2500 watt supply AC
wscdc2500w(31), -- 2500 watt supply DC
wsx4008dc(32), -- 400 watt supply DC
wscac4000w(33), -- 4000 watt supply AC
pwr4000dc(34), -- 4000 watt supply DC
pwr950ac(35), -- 950 watt supply AC
pwr950dc(36), -- 950 watt supply DC
pwr1900ac(37), -- 1900 watt supply AC
pwr1900dc(38), -- 1900 watt supply DC
pwr1900ac6(39), -- 1900 watt supply
-- AC/6 slots
wsx4008ac650w(42), -- 650 watt supply AC
wsx4008dc650w(43), -- 650 watt supply DC
wscac3000w(44), -- 3000 watt supply AC
pwrc451000ac(46), -- 1000 watt supply AC
pwrc452800acv(47),-- 2800 watt supply AC
pwrc451300acv(48),-- 1300 watt supply AC
pwrc451400dcp(49),-- 1400 watt supply DC
wscdc3000w(50), -- 3000 watt supply DC
pwr1400ac(51), -- 1400 watt supply AC
w156(52), -- 156 watt supply AC
wscac6000w(53), -- 6000 watt supply AC
pwr2700ac(54), -- 2700 watt supply AC
pwr2700dc(55), -- 2700 watt supply DC
wscac8700we(58), -- 8700 watt supply AC
pwr2700ac4(59), -- 2700 watt supply AC
pwr2700dc4(60), -- 2700 watt supply DC
pwr400dc(63), -- 400 watt supply DC
pwr400ac(64) -- 400 watt supply AC
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Type of power supply number 2."
::= { chassisGrp 6 }
chassisPs2Status OBJECT-TYPE
SYNTAX INTEGER {
other(1), -- none of the following
ok(2), -- status ok
minorFault(3), -- minor problem
majorFault(4) -- major problem
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Status of power supply number 2. If the status is
not ok, the value of chassisPs2TestResult gives
more detailed information about the power supply's
failure condition(s)."
::= { chassisGrp 7 }
chassisPs2TestResult OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Test result for power supply number 2. A zero
indicates that the supply passed all tests. Bits
set in the result indicate error conditions."
::= { chassisGrp 8 }
chassisFanStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1), -- none of the following
ok(2), -- status ok
minorFault(3), -- minor problem
majorFault(4) -- major problem
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Status of the chassis fan. If the status is not
ok, the value of chassisFanTestResult gives more
detailed information about the fan's failure
condition(s)."
::= { chassisGrp 9 }
chassisFanTestResult OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Test result for the chassis fan. A zero indicates
that the fan passed all tests. Bits set in the
result indicate error conditions."
::= { chassisGrp 10 }
chassisMinorAlarm OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The chassis minor alarm status."
::= { chassisGrp 11 }
chassisMajorAlarm OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The chassis major alarm status."
::= { chassisGrp 12 }
chassisTempAlarm OBJECT-TYPE
SYNTAX INTEGER {
off(1), -- temperature within normal
-- range
on(2), -- temperature too high
critical(3) -- critical temperature,
-- system shut down imminent
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The chassis temperature alarm status."
::= { chassisGrp 13 }
chassisNumSlots OBJECT-TYPE
SYNTAX INTEGER (1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The number of slots in the chassis available for
plug-in modules."
::= { chassisGrp 14 }
chassisSlotConfig OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "An indication of which slots in the chassis have
modules inserted. This is an integer value with
bits set to indicate configured modules. It can be
interpreted as a sum of f(x) as x goes from 1 to
the number of slots, where f(x) = 0 for no module
inserted and f(x) = exp(2, x-1) for a module
inserted."
::= { chassisGrp 15 }
chassisModel OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The manufacturer's model number for the chassis."
::= { chassisGrp 16 }
chassisSerialNumber OBJECT-TYPE
SYNTAX INTEGER (0..999999999)
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "The serial number of the chassis in a numeric
format. If the chassis uses an alphanumeric
serial number, this MIB object will return 0.
This object is deprecated and replaced by
entPhysicalSerialNum in ENTITY-MIB."
::= { chassisGrp 17 }
-- chassis component table
chassisComponentTable OBJECT-TYPE
SYNTAX SEQUENCE OF ChassisComponentEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION "A list of the chassis related components in the
chassis.
This table is deprecated and replaced by
entPhysicalTable in ENTITY-MIB."
::= { chassisGrp 18 }
chassisComponentEntry OBJECT-TYPE
SYNTAX ChassisComponentEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION "Entry containing information about one component
in the chassis."
INDEX { chassisComponentIndex }
::= { chassisComponentTable 1 }
ChassisComponentEntry ::=
SEQUENCE {
chassisComponentIndex
INTEGER,
chassisComponentType
INTEGER,
chassisComponentSerialNumber
DisplayString,
chassisComponentHwVersion
DisplayString,
chassisComponentModel
DisplayString
}
chassisComponentIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "A unique value for each chassis related component
within the chassis."
::= { chassisComponentEntry 1 }
chassisComponentType OBJECT-TYPE
SYNTAX INTEGER {
unknown(1), -- unknown chassis component
wsc6000cl(2), -- clock module for cat6000
wsc6000vtt(3), -- VTT module for cat6000
wsc6000tempSensor(4), -- Temp Sensor for cat6000
wsc6513Clock(5), -- clock for WS-C6513
clk7600(6), -- clock module for cisco7600
ws9SlotFan(7), -- Catalyst 6000 Fan Tray for
-- 9-Slot Systems
fanMod9(8), -- Cisco 7609 and Catalyst
-- 6509-NEB-A Fan Tray
wsc6506eFan(10), -- Catalyst 6506 E FAN Tray
wsc6509eFan(11), -- Catalyst 6509 E FAN Tray
wsc6503eFan(13), -- Catalyst 6503 E FAN Tray
wsc6000vtte(14), -- VTT module for cat6000 E
fanMod4Hs(15), -- Fan module for cisco7604
-- and WS-C6504
fan6524(16), -- Catalyst 6524 Series FAN Tray
fanMod6Shs(17), -- 6-slot FAN for CISCO7606-S
fanMod9Shs(18), -- 9-slot FAN for CISCO7609-S
fanMod9St(19), -- 9-slot FAN for CISCO7609-S
fanMod3Hs(21) -- Fan Tray for CISCO7603-S
}
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "The type of the chassis component."
::= { chassisComponentEntry 2 }
chassisComponentSerialNumber OBJECT-TYPE
SYNTAX DisplayString (SIZE (0 .. 20))
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "The serial number of the chassis component."
::= { chassisComponentEntry 3 }
chassisComponentHwVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0 .. 20))
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "The hardware version of the chassis component."
::= { chassisComponentEntry 4 }
chassisComponentModel OBJECT-TYPE
SYNTAX DisplayString (SIZE (0 .. 20))
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "The manufacturer's model number for the chassis
component."
::= { chassisComponentEntry 5 }
chassisSerialNumberString OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The serial number of the chassis. This MIB object
will return the chassis serial number for any
chassis that either a numeric or an alphanumeric
serial number is being used."
::= { chassisGrp 19 }
chassisPs3Type OBJECT-TYPE
SYNTAX INTEGER {
other(1), -- none of the following
none(2), -- no power supply
wsx4008(25), -- 400 watt supply
wsx4008dc(32), -- 400 watt supply DC
wsx4008ac650w(42), -- 650 watt supply AC
wsx4008dc650w(43) -- 650 watt supply DC
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Type of power supply number 3. This object is
only supported by systems that can have 3 or more
power supplies."
::= { chassisGrp 20 }
chassisPs3Status OBJECT-TYPE
SYNTAX INTEGER {
other(1), -- none of the following
ok(2), -- status ok
minorFault(3), -- minor problem
majorFault(4) -- major problem
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Status of power supply number 3. If the status is
not ok, the value of chassisPs3TestResult gives
more detailed information about the power supply's
failure condition(s). This object is only
supported by systems that can have 3 or more
power supplies."
::= { chassisGrp 21 }
chassisPs3TestResult OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Test result for power supply number 3. A zero
indicates that the supply passed all tests. Bits
set in the result indicate error conditions. This
object is only supported by systems that can
have 3 or more power supplies."
::= { chassisGrp 22 }
chassisPEMInstalled OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates whether Power Entry Module is installed
into the Chassis or not. Power Entry Module is a
connection into the system for an external
power supply of -48 Volts. This object is only
supported by systems that can have 3 or more power
supplies."
::= { chassisGrp 23 }
-- the module group
moduleTable OBJECT-TYPE
SYNTAX SEQUENCE OF ModuleEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A list of module entries. The number of entries
is the number of modules in the chassis."
::= { moduleGrp 1 }
moduleEntry OBJECT-TYPE
SYNTAX ModuleEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Entry containing information about one module in
the chassis."
INDEX { moduleIndex }
::= { moduleTable 1 }
ModuleEntry ::=
SEQUENCE {
moduleIndex
INTEGER,
moduleType
INTEGER,
moduleSerialNumber
INTEGER,
moduleHwHiVersion
INTEGER,
moduleHwLoVersion
INTEGER,
moduleFwHiVersion
INTEGER,
moduleFwLoVersion
INTEGER,
moduleSwHiVersion
INTEGER,
moduleSwLoVersion
INTEGER,
moduleStatus
INTEGER,
moduleTestResult
INTEGER,
moduleAction
INTEGER,
moduleName
DisplayString,
moduleNumPorts
INTEGER,
modulePortStatus
OCTET STRING,
moduleSubType
INTEGER,
moduleModel
DisplayString,
moduleHwVersion
DisplayString,
moduleFwVersion
DisplayString,
moduleSwVersion
DisplayString,
moduleStandbyStatus
INTEGER,
moduleIPAddress
IpAddress,
moduleIPAddressVlan
VlanIndex,
moduleSubType2
INTEGER,
moduleSlotNum
INTEGER,
moduleSerialNumberString
DisplayString,
moduleEntPhysicalIndex
PhysicalIndex,
moduleAdditionalStatus
BITS
}
moduleIndex OBJECT-TYPE
SYNTAX INTEGER (1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A unique value for each module within the
chassis."
::= { moduleEntry 1 }
moduleType OBJECT-TYPE
SYNTAX INTEGER {
other(1), -- none of the following
empty(2), -- nothing installed
wsc1000(3), -- 2+8 Port CDDI Concentrator
wsc1001(4), -- 2+8 Port FDDI Concentrator
wsc1100(5), -- 2+16 Port FDDI/CDDI Concentrator
wsc1200(11), -- 2+8 Port FDDI/Ethernet Switch
wsc1400(12), -- 2 slot FDDI/CDDI Concentrator
-- the following modules are for the WS-C1400
wsx1441(13), -- 8 port Multi Mode FDDI (MIC connector)
wsx1444(14), -- 8 port Single Mode FDDI (ST connector)
wsx1450(15), -- 2 port MM FDDI (MIC), 12 port
-- CDDI(RJ-45)
wsx1483(16), -- 16 port CDDI (RJ-45 connector)
wsx1454(17), -- 2 port SM FDDI (ST), 12 port CDDI
-- (RJ-45)
wsx1455(18), -- 10 port MM FDDI (SC connector)
wsx1431(19), -- 4 port Multi Mode FDDI (MIC connector)
wsx1465(20), -- 2 port MM FDDI (SC), 12 port CDDI
-- (RJ-45)
wsx1436(21), -- 4 port SM FDDI (ST), 4 port MM FDDI
-- (MIC)
wsx1434(22), -- 4 port Single Mode FDDI (ST connector)
-- the following modules are for the WSC-5000 series
wsx5009(23), -- Supervisor Module 1, 2 100 BaseTX
-- (RJ-45/MII)
wsx5013(24), -- 24 port 10BaseT (RJ-45 connector)
wsx5011(25), -- 12 port 10BaseFL MultiMode (ST
-- connector)
wsx5010(26), -- 24 port 10BaseT (Telco connector)
wsx5113(27), -- 12 port 100BaseTX (RJ-45 connector)
wsx5101(28), -- 1 dual attach Multi Mode FDDI
-- (MIC connector)
wsx5103(29), -- 1 dual attach CDDI (RJ-45 connector)
wsx5104(30), -- 1 dual attach Single Mode FDDI (ST
-- connector)
wsx5155(32), -- 1 port Multi Mode OC-3 ATM (SC
-- connector)
wsx5154(33), -- 1 port Single Mode OC-3 ATM (SC
-- connector)
wsx5153(34), -- 1 port UTP OC-3 ATM (RJ-45 connector)
wsx5111(35), -- 12 port 100BaseFX Multi Mode (SC
-- connector)
wsx5213(36), -- 12 port 10/100BaseTX (RJ-45 connector)
wsx5020(37), -- 48 port 4 segment 10BaseT (Telco
-- connector)
wsx5006(38), -- Supervisor Mod 1, 2 100BaseFX Multi Mode
-- (SC)
wsx5005(39), -- Supervisor Mod 1, 2 100BaseFX Single
-- Mode (SC)
wsx5509(40), -- Supervisor Mod 2, 2 100BaseTX
-- (RJ-45/MII)
wsx5506(41), -- Supervisor Mod 2, 2 100BaseFX Multi Mode
-- (SC)
wsx5505(42), -- Supervisor Mod 2, 2 100BaseFX Single
-- Mode (SC)
wsx5156(43), -- 1 dual phy UTP OC-3 ATM (RJ-45
-- connector)
wsx5157(44), -- 1 dual phy Single Mode OC-3 ATM (SC
-- connector)
wsx5158(45), -- 1 dual phy Multi Mode OC-3 ATM (SC
-- connector)
wsx5030(46), -- 16 port Token Ring (RJ-45 connector)
wsx5114(47), -- 6 port SM, 6 port MM 100BaseFX (SC
-- connector)
wsx5223(48), -- 24 port 3 segment 100BaseTX (RJ-45
-- connector)
wsx5224(49), -- 24 port 10/100BaseTX (RJ-45 connector)
wsx5012(50), -- 48 port 10BaseT (Telco connector)
wsx5302(52), -- Vlan router
wsx5213a(53), -- 12 port 10/100BaseTX (RJ-45 connector)
wsx5380(54), -- Network Analysis Module
wsx5201(55), -- 12 port 100BaseFX Multi Mode (SC
-- connector)
wsx5203(56), -- 12 port 10/100BaseTX (RJ-45 connector)
wsx5530(57), -- Supervisor Module 3
wsx5161(61), -- 1 dual phy Multi Mode OC-12 ATM (SC
-- connector)
wsx5162(62), -- 1 dual phy Single Mode OC-12 ATM (SC
-- connector)
wsx5165(65), -- ATM bridge
wsx5166(66), -- 1 dual phy DS3 ATM (BNC connector)
wsx5031(67), -- 16 port Multi Mode Token Ring (ST
-- connector)
wsx5410(68), -- 9 port 1000BaseX (GBIC connector)
wsx5403(69), -- 3 port 1000BaseX (GBIC connector)
wsx5201r(73), -- 12 port 100BaseFX Multi Mode (SC
--connector)
wsx5225r(74), -- 24 port 10/100BaseTX (RJ-45 connector)
wsx5014(75), -- 48 port 10BaseT (RJ-45 connector)
wsx5015(76), -- 24 port 10BaseFL (MT-RJ connector)
wsx5236(77), -- 24 port 100BaseFX Multi Mode (MT-RJ
-- connector)
wsx5540(78), -- Supervisor Module 2 GS
wsx5234(79), -- 24 port 10/100BaseTX (RJ-45 connector)
wsx5012a(81), -- 48 port 10BaseT (Telco connector)
wsx5167(82), -- 1 dual phy Multi Mode OC-3 ATM (SC
-- connector)
wsx5239(83), -- 36 port 10/100BaseTX (Telco connector)
wsx5168(84), -- 1 dual phy Single Mode OC-3 ATM (SC
-- connector)
wsx5305(85), -- 8 port 100BaseFX MM (SC)/Ethernet bridge
wsx5550(87), -- Supervisor Module 3 GS, 2 port GBIC
wsf5541(88), -- RSFC for wsx5540, wsx5550
wsx5534(91), -- Supervisor Module 3 FSX
wsx5536(92), -- Supervisor Module 3 FLX
wsx5237(96), -- 24 port 100BaseFX Single Mode (MT-RJ
-- connector)
-- the following modules are for the WSC-6000 series
wsx6ksup12ge(200), -- 2 port 1000BaseX Supervisor Mod
-- (GBIC)
wsx6408gbic(201), -- 8 port 1000BaseX (GBIC)
wsx6224mmmt(202), -- 24 port 100BaseFX MM (MT-RJ)
wsx6248rj45(203), -- 48 port 10/100BaseTX (RJ-45)
wsx6248tel(204), -- 48 port 10/100BaseTX (Telco)
wsx6302msm(206), -- Multilayer switch module
wsf6kmsfc(207), -- Multilayer switch feature card
wsx6024flmt(208), -- 24 port 10BaseFL (MT-RJ)
wsx6101oc12mmf(209),-- 1 port Multi Mode OC-12 ATM (SC)
wsx6101oc12smf(210),-- 1 port Single Mode OC-12 ATM (SC)
wsx6416gemt(211), -- 16 port 1000BaseSX (MT-RJ)
wsx61822pa(212), -- 2 port adapter FlexWAN Module
osm2oc12AtmMM(213),-- 2-port OC-12 ATM MM
osm2oc12AtmSI(214),-- 2-port OC-12 ATM SI
osm4oc12PosMM(216),-- 4-port OC-12c POS MM
osm4oc12PosSI(217),-- 4-port OC-12c POS SI
osm4oc12PosSL(218),-- 4-port OC-12c POS SL
wsx6ksup1a2ge(219),-- 2 port 1000BaseX Supervisor Mod
-- (GBIC)
wsx6302amsm(220), -- Multilayer switch module (Rev. A)
wsx6416gbic(221), -- 16 port 1000BaseX (GBIC)
wsx6224ammmt(222), -- 24 port 100BaseFX MM (MT-RJ),
-- Enhanced QoS
wsx6380nam(223), -- Network Analysis Module
wsx6248arj45(224), -- 48 port 10/100BaseTX (RJ-45)
-- Enhanced QoS
wsx6248atel(225), -- 48 port 10/100BaseTX (Telco)
-- Enhanced QoS
wsx6408agbic(226), -- 8 port 1000BaseX (GBIC),Enhanced
-- QoS
wsx6608t1(229), -- 8 port T1 (1.544 Mps)
wsx6608e1(230), -- 8 port E1 (2.048 Mps)
wsx6624fxs(231), -- 24 port FXS Analog station module
wsx6316getx(233), -- 16 port 1000BaseT (RJ-45)
wsf6kmsfc2(234), -- Multilayer switch feature card II
wsx6324mmmt(235), -- 24 port 100BaseFX MM (MT-RJ)
wsx6348rj45(236), -- 48 port 10/100BaseTX (RJ-45)
wsx6ksup22ge(237), -- 2 port 1000BaseX Supervisor Mod 2
-- (GBIC)
wsx6324sm(238), -- 24 port 100BaseFX SM (MT-RJ)
wsx6516gbic(239), -- 16 port 1000BaseX (GBIC)
osm4geWanGbic(240), -- 4 port 1000BaseX (GBIC)
osm1oc48PosSS(241), -- 1 port OC-48 POS SS
osm1oc48PosSI(242), -- 1 port OC-48 POS SI
osm1oc48PosSL(243), -- 1 port OC-48 POS SL
wsx6381ids(244), -- Intrusion Detection module
wsc6500sfm(245), -- Switch Fabric Module
osm16oc3PosMM(246), -- 16 port OC3 POS MM
osm16oc3PosSI(247), -- 16 port OC3 POS SI
osm16oc3PosSL(248), -- 16 port OC3 POS SL
osm2oc12PosMM(249), -- 2 port OC12 POS MM
osm2oc12PosSI(250), -- 2 port OC12 POS SI
osm2oc12PosSL(251), -- 2 port OC12 POS SL
wsx650210ge(252), -- 1 port 10 Gigabit Ethernet
osm8oc3PosMM(253), -- 8 port OC3 POS MM
osm8oc3PosSI(254), -- 8 port OC3 POS SI
osm8oc3PosSL(255), -- 8 port OC3 POS SL
wsx6548rj45(258), -- 48 port 10/100BaseTX (RJ-45)
wsx6524mmmt(259), -- 24 port 100BaseFX MM (MT-RJ)
wsx6066SlbApc(260), -- SLB Application Processor Complex
wsx6516getx(261), -- 16 port 10/100/1000BaseT (RJ-45)
osm2oc48OneDptSS(265), -- 2 port OC48 1 DPT SS
osm2oc48OneDptSI(266), -- 2 port OC48 1 DPT SI
osm2oc48OneDptSL(267), -- 2 port OC48 1 DPT SL
osm2oc48OneDptSSDual(268), -- 2 port OC48 DPT SS
-- dual-natured
osm2oc48OneDptSIDual(269), -- 2 port OC48 DPT SI
-- dual-natured
osm2oc48OneDptSLDual(270), -- 2 port OC48 DPT SL
-- dual-natured
wsx6816gbic(271), -- 16 port 1000BaseX (Layer 3)
osm4choc12T3MM(272), -- 4 port OC-12 Multimode
osm4choc12T3SI(273), -- 4 port OC-12 Singlemode
-- Intermediate
osm8choc12T3MM(274), -- 8 port OC-12 Multimode
osm8choc12T3SI(275), -- 8 port OC-12 Singlemode
-- Intermediate
osm1choc48T3SS(276), -- 1 port OC-48 Singlemode Short
osm2choc48T3SS(277), -- 2 port OC-48 Singlemode Short
wsx6500sfm2(278), -- Switch Fabric Module 136
osm1choc48T3SI(279), -- 1 port OC-48 Singlemode
-- Intermediate
osm2choc48T3SI(280), -- 2 port OC-48 Singlemode
-- Intermediate
wsx6348rj21(281), -- 48 port 10/100BaseTX (RJ-21)
wsx6548rj21(282), -- 48 port 10/100BaseTX (RJ-21)
wsSvcCmm(284), -- AVVID Services Module
wsx650110gex4(285), -- 1 port 10 Gigabit Ethernet (EX4)
osm4oc3PosSI(286), -- 4 port OC3 POS SI
osm4oc3PosMM(289), -- 4 port OC3 POS MM
wsSvcIdsm2(290), -- Intrusion Detection module
wsSvcNam2(291), -- Network Analysis Module
wsSvcFwm1(292), -- Firewall Module
wsSvcCe1(293), -- Web Cache/Content Engine Module
wsSvcSsl1(294), -- SSL Module
osm8choc3DS0SI(295), -- 8 port OC3 DS0 SI
osm4choc3DS0SI(296), -- 4 port OC3 DS0 SI
osm1choc12T1SI(297), -- 1 port OC3 T1 SI
-- the following modules are for the WSC-4000 series
wsx4012(300), -- Supervisor Module
wsx4148rj(301), -- 48 port 10/100BaseTX (RJ-45)
wsx4232gbrj(302), -- 2 1000X (GBIC), 32 10/100BaseTX
-- (RJ-45)
wsx4306gb(303), -- 6 port 1000BaseX (GBIC)
wsx4418gb(304), -- 18 port 1000BaseX (GBIC)
wsx44162gbtx(305), -- 2 1000BaseX (GBIC), 16 1000BaseT
-- (RJ-45)
wsx4912gb(306), -- 12 port 1000BaseX (GBIC)
wsx2948gbrj(307), -- 2 1000X (GBIC), 48 10/100BaseTX
-- (RJ-45)
wsx2948(309), -- Supervisor Module
wsx4912(310), -- Supervisor Module
wsx4424sxmt(311), -- 24 port 1000BaseSX (MT-RJ)
wsx4232rjxx(312), -- 32 port 10/100 (RJ-45) + uplink
-- submodule
wsx4148rj21(313), -- 48 port 10/100BaseTX (RJ-21)
wsx4124fxmt(317), -- 24 port 100BaseFX MM (MT-RJ)
wsx4013(318), -- Supervisor Module 2, 2 port
-- 1000X(GBIC)
wsx4232l3(319), -- 32 10/100TX(RJ-45), 2 1000X
-- Routed port
wsx4604gwy(320), -- 1 port 1000 Mb routed + 1 daughter
-- card
wsx44122Gbtx(321), -- 2 1000BaseX(GBIC), 12 1000BaseT
-- (RJ-45)
wsx2980(322), -- Supervisor module for wsc2980g
wsx2980rj(323), -- 48 port 10/100BaseTX
wsx2980gbrj(324), -- 32 port 10/100BaseTX + 2 port
-- 1000X
wsx4019(325), -- Switch Fabric Module
wsx4148rj45v(326), -- 48 port 10/100BaseT Voice Power
-- module
wsx4424gbrj45(330),-- 24 10/100/1000BaseTX (RJ-45)
wsx4148fxmt(331), -- 48 port 100BaseFX MM (MT-RJ)
wsx4448gblx(332), -- 48 port 1000BaseX (SFP GBIC)
wsx4448gbrj45(334), -- 48 port 10/100/1000Base TX
-- (RJ-45)
wsx4148lxmt(337), -- 48 port 100BaseLX
wsx4548gbrj45(339), -- 48 port 10/100/1000Base TX
-- (RJ-45)
wsx4548gbrj45v(340), -- 48 port 10/100/1000T Voice
-- module
wsx4248rj21v(341), -- 48 port 10/100 (RJ-21) Voice
-- module
wsx4302gb(342), -- 2 port 1000BaseX (GBIC)
wsx4248rj45v(343), -- 48 port 10/100BaseT Voice Power
-- module
wsx2948ggetx(345), -- Supervisor Module for
-- wsc2948ggetx
wsx2948ggetxgbrj(346), -- 4 1000Base FX(SFP), 48
-- 10/100/1000 BaseTX (RJ-45)
-- the following modules are for the WSC-6000 series
wsx6516aGbic(502), -- 16 port 1000BaseX (GBIC)
wsx6148getx(503), -- 48 port 10/100/1000BaseT(RJ-45)
wsx6148x2rj45(506), -- 96 port 10/100BaseTX (RJ-45)
wsx6196rj21(507), -- 96 port 10/100BaseTX (RJ-21)
wssup32ge3b(509), -- 8 port 1000BaseX Supervisor
-- module
wssup3210ge3b(510), -- 2 port 10GBaseX Supervisor
-- module
mec6524gs8s(511), -- 24 port SFP with 8 SFP uplinks
mec6524gt8s(512), -- 24 port 10/100/1000BaseT with
-- 8 SFP uplinks
me6524msfc2a(598), -- Multilayer switch feature card
-- II A
-- WAN module for c6k and 76xx
osm12ct3T1(600), -- 12 port CT3 T1
osm24t3e3(602), -- 24 port T3 E3
osm1choc12T3SI(604), -- 1 port OC-12 Singlemode
-- Intermediate
osm2choc12T3SI(605), -- 2 port OC-12 Singlemode
-- Intermediate
osm2oc12AtmMMPlus(606), -- 2-port OC-12 ATM MM
osm2oc12AtmSIPlus(607), -- 2-port OC-12 ATM SI
osm2oc12PosMMPlus(608), -- 2 port OC12 POS MM
osm2oc12PosSIPlus(609), -- 2 port OC12 POS SI
osm16oc3PosSIPlus(610), -- 16 port OC3 POS SI
osm1oc48PosSSPlus(611), -- 1 port OC-48 POS SS
osm1oc48PosSIPlus(612), -- 1 port OC-48 POS SI
osm1oc48PosSLPlus(613), -- 1 port OC-48 POS SL
osm4oc3PosSIPlus(614), -- 4 port OC3 POS SI
osm8oc3PosSLPlus(615), -- 8 port OC3 POS SL
osm8oc3PosSIPlus(616), -- 8 port OC3 POS SI
osm4oc12PosSIPlus(617), -- 4 port OC12 POS SI
wsSvcIpSec1(903), -- VPN security blade module
wsSvcCsg1(911), -- Content Services Gateway Module
wsx6148rj45v(912), -- 48 port 10/100BaseTX (RJ-45)
wsx6148rj21v(913), -- 48 port 10/100BaseTX (RJ-21)
wsSvcNam1(914), -- Network Analysis Module
wsx6548getx(915), -- 48 port 10/100/1000BaseT(RJ-45)
wsx6148agetx(921), -- 48 port
-- 10/100/1000BaseTX (RJ-45)
wsx6148arj45(923), -- 48 port 10/100BaseTX (RJ-45)
wsSvcWlan1k9(924), -- Wireless LAN Application Module
wsSvcAon1k9(925), -- Application Oriented Network
-- Switching
ace106500k9(926), -- Application Control Engine
-- 10G Service Module
wsSvcWebVpnk9(927), -- Web VPN Module
wsx6148FeSfp(928), -- 48 port 100Base-X SFP Module
wsSvcAdm1k9(929), -- Anomaly Detection Module
wsSvcAgm1k9(930), -- Anomaly Guard Module
ace046500k9(936), -- Application Control Engine
-- 4G Service Module
wssup720(1001), -- Supervisor Mod 720 CPU board
-- (moduleSubType2)
wssup720base(1002), -- Supervisor Mod 720 base board
wsx6748getx(1007), -- 48 port 10/100/1000 (RJ-45)
wsx670410ge(1008), -- 4 port 10 GE
wsx6748sfp(1009), -- 48 port 1000Base FX (SFP GBIC)
wsx6724sfp(1010), -- 24 port 1000Base FX (SFP GBIC)
wsx670810ge(1016), -- 8 port X2 10 GE with DFC
-- constellation 2 WAN module
wsx65822pa(1101) -- Enhanced FlexWAN Module
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The type of module."
::= { moduleEntry 2 }
moduleSerialNumber OBJECT-TYPE
SYNTAX INTEGER (0..999999999)
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "The serial number of the module in a numeric
format. If the module uses an alphanumeric serial
number, this MIB object will return 0.
This object is deprecated and replaced by
entPhysicalSerialNum in ENTITY-MIB."
::= { moduleEntry 3 }
moduleHwHiVersion OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "The high part of the hardware version of the
module.
For example, if the hardware version is 3.1, the
value of moduleHwHiVersion is 3.
This object is deprecated and replaced by
entPhysicalHardwareRev in ENTITY-MIB."
::= { moduleEntry 4 }
moduleHwLoVersion OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "The low part of the hardware version of the
module.
For example, if the hardware version is 3.1, the
value of moduleHwLoVersion is 1.
This object is deprecated and replaced by
entPhysicalHardwareRev in ENTITY-MIB."
::= { moduleEntry 5 }
moduleFwHiVersion OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "The high part of the firmware version number. For
example, if the firmware version is 3.1, the value
of moduleFwHiVersion is 3.
This object is deprecated and replaced by
entPhysicalFirmwareRev in ENTITY-MIB."
::= { moduleEntry 6 }
moduleFwLoVersion OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "The low part of the firmware version number. For
example, if the firmware version is 3.1, the value
of moduleFwLoVersion is 1.
This object is deprecated and replaced by
entPhysicalFirmwareRev in ENTITY-MIB."
::= { moduleEntry 7 }
moduleSwHiVersion OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "The high part of the software version number. For
example, if the software version is 3.1, the value
of moduleSwHiVersion is 3.
This object is deprecated and replaced by
entPhysicalSoftwareRev in ENTITY-MIB."
::= { moduleEntry 8 }
moduleSwLoVersion OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "The low part of the software version number. For
example, if the software version is 3.1, the value
of moduleSwLoVersion is 1.
This object is deprecated and replaced by
entPhysicalSoftwareRev in ENTITY-MIB."
::= { moduleEntry 9 }
moduleStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1), -- none of the following
ok(2), -- status ok
minorFault(3), -- minor problem
majorFault(4) -- major problem
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The operational status of the module. If the
status is not ok, the value of moduleTestResult
gives more detailed information about the
module's failure condition(s)."
::= { moduleEntry 10 }
moduleTestResult OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The result of the module's self test. A zero
indicates that the module passed all tests. Bits
set in the result indicate error conditions."
::= { moduleEntry 11 }
moduleAction OBJECT-TYPE
SYNTAX INTEGER {
other(1),
reset(2),
enable(3),
disable(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "This object, when read, returns one of the
following results:
other(1): module permanently enabled
enable(3): module currently enabled
disable(4): module currently disabled
Setting this object to one of the acceptable
values gives the following results:
other(1): gives an error
reset(2): resets the module's control logic
enable(3): if the module status is configurable,
enables the module, else gives error
disable(4): if the module status is
configurable, disables the module,
else gives error.
Setting this object to any other values results in
an error."
::= { moduleEntry 12 }
moduleName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "A descriptive string used by the network
administrator to name the module."
::= { moduleEntry 13 }
moduleNumPorts OBJECT-TYPE
SYNTAX INTEGER (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The number of ports supported by the module."
::= { moduleEntry 14 }
modulePortStatus OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A series of bytes containing status information
about the module and each of the ports on the
module.
The first byte contains the status for the module
(same value as moduleStatus), and subsequent bytes
contain status for the first through the last
ports on the module (same value as
portOperStatus)."
::= { moduleEntry 15 }
moduleSubType OBJECT-TYPE
SYNTAX INTEGER {
other(1), -- none of the following
empty(2), -- nothing installed
-- sub modules for the WS-X5505,5506,5509
wsf5510(3), -- EARL 1
wsf5511(4), -- EARL 1+
-- sub modules for the WS-X5302
wsx5304(6), -- VIP II carrier
-- sub modules for the WS-X5530,5540
wsf5520(7), -- EARL 1+
wsf5521(8), -- NFFC
wsf5531(9), -- NFFC II
-- sub modules for the WS-X6K-SUP-2GE
wsf6020(100), -- L2 switching card
wsf6020a(101),-- L2 switching card II
wsf6kpfc(102),-- L3 switching engine
wsf6kpfc2(103),-- L3 switching engine II
wsf6kvpwr(104), -- inline power card
wsf6kdfc(105), -- distributed switching
-- engine
wsf6kpfc2a(106),-- L3 switching engine
-- IIA
wsf6kdfca(107), -- distributed switching
-- engine
-- sub module for SPA Carrier Basecard
vsp300dfc(200), -- VSP 300 Earl7
-- Daughtercard
wsf6kpfc3a(201),
-- Policy feature card 3A
wsf6kdfc3a(202),
-- Distributed forwarding card 3A
wsf6700dfc3a(203),
-- Distributed forwarding card 3A
wsf6kdfc3bxl(205),
-- Distributed forwarding card 3B
-- XL
wsf6kpfc3bxl(206),
-- Policy feature card 3B XL
wsf6700dfc3bxl(207),
-- Distributed forwarding card 3B
-- XL
wsf6700cfc(208),
-- Centralized forwarding card
wsf6kpfc3b(216),
-- Policy feature card 3B
wsf6700dfc3b(217),
-- Distributed forwarding card 3B
wsf6700dfc3c(218),
-- Distributed forwarding card
wsf6700dfc3cxl(221),
-- Distributed forwarding card
wsf6kdfc3b(223),
-- Distributed forwarding card 3B
mec6524pfc3c(224)
-- Policy feature card 3C
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The type of daughterboard attached to this
module."
::= { moduleEntry 16 }
moduleModel OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The manufacturer's model number for the module."
::= { moduleEntry 17 }
moduleHwVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..12))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The hardware version of the module."
::= { moduleEntry 18 }
moduleFwVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..40))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The firmware version of the module."
::= { moduleEntry 19 }
moduleSwVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..40))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The software version of the module."
::= { moduleEntry 20 }
moduleStandbyStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1), -- none of the following
active(2),
standby(3),
error(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Redundant status of a module that supports
redundancy."
::= { moduleEntry 21 }
moduleIPAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION "If the module has a separate IP address to
reach it by, then it is reported here.
Otherwise, this object has a value of
'00000000H'."
::= { moduleEntry 22 }
moduleIPAddressVlan OBJECT-TYPE
SYNTAX VlanIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION "If the moduleIPAddress is valid then this
object reports the VLAN to access that IP
address on. Otherwise this object has a value
of zero."
::= { moduleEntry 23 }
moduleSubType2 OBJECT-TYPE
SYNTAX INTEGER {
other(1), -- none of the following
empty(2), -- nothing installed
-- sub module 2 type for the WS-X5530,5540
wsu5531(3), -- 2 port 10/100BaseTX (RJ-45)
wsu5533(5), -- 2 port 100BaseFX MM (SC)
wsu5534(6), -- 2 port 1000BaseSX (SC)
wsu5535(7), -- 2 port 100BaseFX SM (SC)
wsu5536(8), -- 2 port 1000BaseLX (SC)
wsu5537(9), -- 4 port 10/100BaseTX (RJ-45)
wsu5538(10), -- 4 port 100BaseFX MM (SC)
wsu5539(11), -- 4 port 100BaseFX SM (SC)
wsg6488(102), -- 10GE-LR Serial 1310nm long haul
wsg6489(103), -- 10GE-SX4 850nm WWDM short reach
wsg6483(104), -- 10GE-ER Serial 1550nm extended reach
wsg6485(105), -- 10GE-LX4 Campus 1310nm WWDM long
-- haul/short reach.
wsf6kFe48af(106), -- inline power card
wsf6kGe48af(107), -- inline power card
wsf6kVpwrGe(108), -- inline power card
wsf6kFe48x2af(109), -- inline power card
-- sub module 2 type for cat6k IOS Software
wsf6kmsfc(207), -- Multilayer switch feature card
wsf6kmsfc2(234), -- Multilayer switch feature card II
-- sub module 2 type for WS-X4232,4224,4416
wsu4504fxmt(314), -- 4 port 100BaseFX (MT-RJ)
wsu4502gb(315), -- 2 port 1000BaseX (GBIC)
-- sub module 2 type for Cat6k modules
wssvcidsupg(402), -- IDS 2 accelerator board
wssvccmm6e1(403), -- 6 E1 port adapter
wssvccmm6t1(404), -- 6 T1 port adapter
wssvccmm24fxs(405), -- 24 FXS port adapter
wssvccmmact(406), -- ad-hoc conferencing and
-- transcoding port adapter
wsf6kmsfc2a(599), -- Multilayer switch feature card II A
-- sub module 2 type for sup 720
wssup720(1001) -- Supervisor Mod 720 CPU board
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The type of daughterboard attached to this
module."
::= { moduleEntry 24 }
moduleSlotNum OBJECT-TYPE
SYNTAX INTEGER (1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This value is determined by the chassis slot
number where the module is located. Valid entries
are 1 to the value of chassisNumSlots"
::= { moduleEntry 25 }
moduleSerialNumberString OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The serial number of the module. This MIB object
will return the module serial number for any
module that either a numeric or an alphanumeric
serial number is being used."
::= { moduleEntry 26 }
moduleEntPhysicalIndex OBJECT-TYPE
SYNTAX PhysicalIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The value of the instance of the entPhysicalIndex
object, defined in ENTITY-MIB, for the entity
physical index corresponding to this module."
::= { moduleEntry 27 }
moduleAdditionalStatus OBJECT-TYPE
SYNTAX BITS {
fruInstalled(0),
powerDenied(1),
faulty(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The additional status of the module.
fruInstalled(0) indicates that whether or not
FRU is installed on the module.
powerDenied(1) indicates that whether phones
connected to the ports of this module are
denied of power.
faulty(2) indicates hardware faulty."
::= { moduleEntry 28}
-- the port group
-- Implementation of the port group is current for all Cisco Workgroup
-- Stack products.
portTable OBJECT-TYPE
SYNTAX SEQUENCE OF PortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A list of port entries. The number of entries is
determined by the number of modules in the chassis
and the number of ports on each module."
::= { portGrp 1 }
portEntry OBJECT-TYPE
SYNTAX PortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Entry containing information for a particular
port on a module."
INDEX { portModuleIndex, portIndex }
::= { portTable 1 }
PortEntry ::=
SEQUENCE {
portModuleIndex
INTEGER,
portIndex
INTEGER,
portCrossIndex
INTEGER,
portName
DisplayString,
portType
INTEGER,
portOperStatus
INTEGER,
portCrossGroupIndex
INTEGER,
portAdditionalStatus
INTEGER,
portAdminSpeed
INTEGER,
portDuplex
INTEGER,
portIfIndex
INTEGER,
portSpantreeFastStart
INTEGER,
portAdminRxFlowControl
INTEGER,
portOperRxFlowControl
INTEGER,
portAdminTxFlowControl
INTEGER,
portOperTxFlowControl
INTEGER,
portMacControlTransmitFrames
Counter32,
portMacControlReceiveFrames
Counter32,
portMacControlPauseTransmitFrames
Counter32,
portMacControlPauseReceiveFrames
Counter32,
portMacControlUnknownProtocolFrames
Counter32,
portLinkFaultStatus
INTEGER,
portAdditionalOperStatus
BITS,
portInlinePowerDetect
TruthValue,
portEntPhysicalIndex
PhysicalIndex,
portErrDisableTimeOutEnable
INTEGER
}
portModuleIndex OBJECT-TYPE
SYNTAX INTEGER (1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "An index value that uniquely identifies the
module where this port is located."
::= { portEntry 1 }
portIndex OBJECT-TYPE
SYNTAX INTEGER (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "An index value that uniquely identifies this port
within a module. The value is determined by the
location of the port on the module. Valid entries
are 1 to the value of moduleNumPorts for this
module."
::= { portEntry 2 }
portCrossIndex OBJECT-TYPE
SYNTAX INTEGER (1..4080)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A cross-reference to the port's index within
another mib group. The value is dependent on the
type of port. For an FDDI port, this corresponds
to the snmpFddiPORTIndex."
::= { portEntry 3 }
portName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "A descriptive string used by the network
administrator to name the port."
::= { portEntry 4 }
portType OBJECT-TYPE
SYNTAX INTEGER {
other(1), -- none of the following
cddi(2), -- CDDI (UTP FDDI)
fddi(3), -- Multi Mode fiber FDDI
tppmd(4), -- ANSI standard UTP FDDI
mlt3(5), -- MLT-3 UTP FDDI
sddi(6), -- STP FDDI
smf(7), -- Single Mode fiber FDDI
e10BaseT(8), -- UTP Ethernet
e10BaseF(9), -- Multi Mode fiber Ethernet
scf(10), -- small-connector fiber FDDI
e100BaseTX(11),-- UTP Fast Ethernet (Cat 5)
e100BaseT4(12),-- UTP Fast Ethernet (Cat 3)
e100BaseF(13), -- Multi Mode fiber Fast
-- Ethernet
atmOc3mmf(14), -- Multi Mode fiber OC-3 ATM
atmOc3smf(15), -- Single Mode fiber OC-3 ATM
atmOc3utp(16), -- UTP OC-3 ATM
e100BaseFsm(17), -- Single Mode fiber Fast
-- Ethernet
e10a100BaseTX(18), -- 10/100 UTP Ethernet
-- (Cat 3/5)
mii(19), -- MII Ethernet
vlanRouter(20), -- vlan router connection
remoteRouter(21), --
tokenring(22), -- Token Ring
atmOc12mmf(23),-- Multi Mode fiber OC-12 ATM
atmOc12smf(24),-- Single Mode fiber OC-12
-- ATM
atmDs3(25), -- DS-3 ATM
tokenringMmf(26), -- Multi Mode fiber Token
-- Ring
e1000BaseLX(27), -- Long Wave fiber Giga
-- Ethernet
e1000BaseSX(28), -- Short Wave fiber Giga
-- Ethernet
e1000BaseCX(29), -- Copper Gigabit Ethernet
networkAnalysis(30), -- Network Analysis
-- connection
e1000Empty(31), -- GBIC not installed
e1000BaseLH(32), -- Long Haul fiber Giga
-- Ethernet
e1000BaseT(33), -- Twisted Pair Giga
-- Ethernet
e1000UnsupportedGbic(34),
-- Unsupported Gbic Giga
-- Ethernet
e1000BaseZX(35), -- Extended Reach Giga
-- Ethernet
depi2(36), -- Digital Ethernet Phone
-- Interface 2 Mbps
t1(37), -- T1
e1(38), -- E1
fxs(39), -- FXS
fxo(40), -- FXO
transcoding(41), -- transcoding DSP
conferencing(42),-- conferencing DSP
atmOc12mm(43), -- OC-12 ATM MMF
atmOc12smi(44), -- OC-12 ATM SMIR
atmOc12sml(45), -- OC-12 ATM SML
posOc12mm(46), -- OC-12 POS MM
posOc12smi(47), -- OC-12 POS SMIR
posOc12sml(48), -- OC-12 POS SMLR
posOc48sms(49), -- OC-48 POS SMS
posOc48smi(50), -- OC-48 POS SMIR
posOc48sml(51), -- OC-48 POS SMLR
posOc3mm(52), -- OC-3 POS MM
posOc3smi(53), -- OC-3 POS SMIR
posOc3sml(54), -- OC-3 POS SMLR
intrusionDetect(55), -- intrusion detection
e10GBaseCPX(56), --10GE Parallel 860nm Laser
e10GBaseLX4(57), -- 10GE Wide-WDM 1310nm
-- Laser
e10GBaseEX4(59), -- 10GE Wide-WDM 1550 Laser
e10GEmpty(60), -- 10GE not installed
e10a100a1000BaseT(61), -- 10/100/1000 BaseT
dptOc48mm(62), -- OC-48 DPT MM
dptOc48smi(63), -- OC-48 DPT SMIR
dptOc48sml(64), -- OC-48 DPT SMLR
e10GBaseLR(65), -- 10GE Serial 1310nm Laser
chOc12smi(66), -- OC-12 channelized SMIR
chOc12mm(67), -- OC-12 channelized MM
chOc48ss(68), -- OC-48 channelized SS
chOc48smi(69), -- OC-48 channelized SMIR
e10GBaseSX4(70), -- 10GE Wide-WDM 850nm
-- Laser
e10GBaseER(71), -- 10GE Serial 1550nm Laser
contentEngine(72),-- content engine
-- connection
ssl(73), -- SSL connection
firewall(74), -- Firewall connection
vpnIpSec(75), -- VPN IP Sec connection
ct3(76), -- DS3 Channelized
e1000BaseCwdm1470(77),
-- CWDM 1470 Giga Ethernet
e1000BaseCwdm1490(78),
-- CWDM 1490 Giga Ethernet
e1000BaseCwdm1510(79),
-- CWDM 1510 Giga Ethernet
e1000BaseCwdm1530(80),
-- CWDM 1530 Giga Ethernet
e1000BaseCwdm1550(81),
-- CWDM 1550 Giga Ethernet
e1000BaseCwdm1570(82),
-- CWDM 1570 Giga Ethernet
e1000BaseCwdm1590(83),
-- CWDM 1590 Giga Ethernet
e1000BaseCwdm1610(84),
-- CWDM 1610 Giga Ethernet
e1000BaseBT(85), -- BT Giga Ethernet
e1000BaseUnapproved(86),
-- Unappeoved Giga Ethernet
chOc3smi(87), -- OC-3 channelized SMIR
mcr(88), -- Mobile Context Registry
-- connection
coe(89), -- Content Optimization Engine
-- connection
mwa(90), -- Mobile Wireless Application
-- connection
psd(91), -- Persistent Store Device
-- connection
e100BaseLX(92), -- Long Wave fiber Fast
-- Ethernet
e10GBaseSR(93), -- 10GE Serial 850nm Laser
e10GBaseCX4(94), -- 10GE XAUI Copper
e10GBaseWdm1550(95),
-- 10GE Serial 1550nm Laser
e10GBaseEdc1310(96),
-- 10GE Serial 1310nm EDC Laser
e10GBaseSW(97), -- 10GE Laser
e10GBaseLW(98), -- 10GE Laser
e10GBaseEW(99), -- 10GE Laser
lwa(100), -- Lan Wireless Application
-- connection
aons(101), -- Application Oriented Network
-- Switching
sslVpn(102), -- Web/VPN
e100BaseEmpty(103), -- Fiber Fast Ethernet
-- not installed
adsm(104), -- Distributed Denial of Service
-- Detector
agsm(105), -- Distributed Denial of Service
-- Guard
aces(106), -- Application Control Engine
-- Service
e1000BaseUnknown(1000),
-- Unknown Giga Ethernet
e10GBaseUnknown(1001), -- Unknown 10G
e10GBaseUnapproved(1002), -- Unapproved 10G
e1000BaseWdmRxOnly(1003),
-- WDM Rx ONLY Giga Ether
e1000BaseDwdm3033(1004),
-- DWDM 3033 Giga Ethernet
e1000BaseDwdm3112(1005),
-- DWDM 3112 Giga Ethernet
e1000BaseDwdm3190(1006),
-- DWDM 3190 Giga Ethernet
e1000BaseDwdm3268(1007),
-- DWDM 3268 Giga Ethernet
e1000BaseDwdm3425(1008),
-- DWDM 3425 Giga Ethernet
e1000BaseDwdm3504(1009),
-- DWDM 3504 Giga Ethernet
e1000BaseDwdm3582(1010),
-- DWDM 3582 Giga Ethernet
e1000BaseDwdm3661(1011),
-- DWDM 3661 Giga Ethernet
e1000BaseDwdm3819(1012),
-- DWDM 3819 Giga Ethernet
e1000BaseDwdm3898(1013),
-- DWDM 3898 Giga Ethernet
e1000BaseDwdm3977(1014),
-- DWDM 3977 Giga Ethernet
e1000BaseDwdm4056(1015),
-- DWDM 4056 Giga Ethernet
e1000BaseDwdm4214(1016),
-- DWDM 4214 Giga Ethernet
e1000BaseDwdm4294(1017),
-- DWDM 4294 Giga Ethernet
e1000BaseDwdm4373(1018),
-- DWDM 4373 Giga Ethernet
e1000BaseDwdm4453(1019),
-- DWDM 4453 Giga Ethernet
e1000BaseDwdm4612(1020),
-- DWDM 4612 Giga Ethernet
e1000BaseDwdm4692(1021),
-- DWDM 4692 Giga Ethernet
e1000BaseDwdm4772(1022),
-- DWDM 4772 Giga Ethernet
e1000BaseDwdm4851(1023),
-- DWDM 4851 Giga Ethernet
e1000BaseDwdm5012(1024),
-- DWDM 5012 Giga Ethernet
e1000BaseDwdm5092(1025),
-- DWDM 5092 Giga Ethernet
e1000BaseDwdm5172(1026),
-- DWDM 5172 Giga Ethernet
e1000BaseDwdm5252(1027),
-- DWDM 5252 Giga Ethernet
e1000BaseDwdm5413(1028),
-- DWDM 5413 Giga Ethernet
e1000BaseDwdm5494(1029),
-- DWDM 5494 Giga Ethernet
e1000BaseDwdm5575(1030),
-- DWDM 5575 Giga Ethernet
e1000BaseDwdm5655(1031),
-- DWDM 5655 Giga Ethernet
e1000BaseDwdm5817(1032),
-- DWDM 5817 Giga Ethernet
e1000BaseDwdm5898(1033),
-- DWDM 5898 Giga Ethernet
e1000BaseDwdm5979(1034),
-- DWDM 5979 Giga Ethernet
e1000BaseDwdm6061(1035),
-- DWDM 6061 Giga Ethernet
e10GBaseWdmRxOnly(1036),
-- DWDM 10G WDM Rx ONLY
e10GBaseDwdm3033(1037),
-- DWDM 10G 3033 Laser
e10GBaseDwdm3112(1038),
-- DWDM 10G 3112 Laser
e10GBaseDwdm3190(1039),
-- DWDM 10G 3190 Laser
e10GBaseDwdm3268(1040),
-- DWDM 10G 3268 Laser
e10GBaseDwdm3425(1041),
-- DWDM 10G 3425 Laser
e10GBaseDwdm3504(1042),
-- DWDM 10G 3504 Laser
e10GBaseDwdm3582(1043),
-- DWDM 10G 3582 Laser
e10GBaseDwdm3661(1044),
-- DWDM 10G 3661 Laser
e10GBaseDwdm3819(1045),
-- DWDM 10G 3819 Laser
e10GBaseDwdm3898(1046),
-- DWDM 10G 3898 Laser
e10GBaseDwdm3977(1047),
-- DWDM 10G 3977 Laser
e10GBaseDwdm4056(1048),
-- DWDM 10G 4056 Laser
e10GBaseDwdm4214(1049),
-- DWDM 10G 4214 Laser
e10GBaseDwdm4294(1050),
-- DWDM 10G 4294 Laser
e10GBaseDwdm4373(1051),
-- DWDM 10G 4373 Laser
e10GBaseDwdm4453(1052),
-- DWDM 10G 4453 Laser
e10GBaseDwdm4612(1053),
-- DWDM 10G 4612 Laser
e10GBaseDwdm4692(1054),
-- DWDM 10G 4692 Laser
e10GBaseDwdm4772(1055),
-- DWDM 10G 4772 Laser
e10GBaseDwdm4851(1056),
-- DWDM 10G 4851 Laser
e10GBaseDwdm5012(1057),
-- DWDM 10G 5012 Laser
e10GBaseDwdm5092(1058),
-- DWDM 10G 5092 Laser
e10GBaseDwdm5172(1059),
-- DWDM 10G 5172 Laser
e10GBaseDwdm5252(1060),
-- DWDM 10G 5252 Laser
e10GBaseDwdm5413(1061),
-- DWDM 10G 5413 Laser
e10GBaseDwdm5494(1062),
-- DWDM 10G 5494 Laser
e10GBaseDwdm5575(1063),
-- DWDM 10G 5575 Laser
e10GBaseDwdm5655(1064),
-- DWDM 10G 5655 Laser
e10GBaseDwdm5817(1065),
-- DWDM 10G 5817 Laser
e10GBaseDwdm5898(1066),
-- DWDM 10G 5898 Laser
e10GBaseDwdm5979(1067),
-- DWDM 10G 5979 Laser
e10GBaseDwdm6061(1068),
-- DWDM 10G 6061 Laser
e1000BaseBX10D(1069),
-- Giga Ethernet bi-directional 10km
-- Downlink over SMF
e1000BaseBX10U(1070),
-- Giga Ethernet bi-directional 10km
-- Uplink over SMF
e100BaseUnknown(1071),
-- Unknown Fiber Fast Ethernet
e100BaseUnapproved(1072),
-- Unapproved Fiber Fast Ethernet
e100BaseSX(1073),
-- Short Wave Fiber Fast Ethernet
e100BaseBX10D(1074),
-- Fiber Fast Ethernet bi-directional
-- 10km Downlink over SMF
e100BaseBX10U(1075),
-- Fiber Fast Ethernet bi-directional
-- 10km Uplink over SMF
e10GBaseBad(1076), -- Bad 10G
e10GBaseZR(1077), -- 10GE Laser
e100BaseEX(1078),
-- Fiber Fast Ethernet
e100BaseZX(1079)
-- Extended Reach Fiber Fast Ethernet
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The type of physical layer medium dependent
interface on the port."
::= { portEntry 5 }
portOperStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1), -- none of the following
ok(2), -- status ok
minorFault(3), -- minor problem
majorFault(4) -- major problem
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The current operational status of the port."
::= { portEntry 6 }
portCrossGroupIndex OBJECT-TYPE
SYNTAX INTEGER (1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A cross-reference to another mib group for this
port. The value is dependent on the type of port.
For an FDDI port this corresponds to the
snmpFddiPORTSMTIndex."
::= { portEntry 7 }
portAdditionalStatus OBJECT-TYPE
SYNTAX INTEGER (0..7)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Additional status information for the port. The
value is a sum. It initially takes the value zero,
then for each state that is true, 2 raised to a
power is added to the sum. The powers are
according to the following table:
State Power
Transmit 0
Receive 1
Collision 2
Transmit state indicates that at least one packet
was transmitted by the port in the last polling
period. Receive state indicates that at least one
packet was received by the port in the last
polling period. Collision state indicates that
at least one collision was detected on the port
in the last polling period.
Note that if a state is not applicable to a
particular port or additional status is not
supported on a particular port, its value is
always false for that port."
::= { portEntry 8 }
portAdminSpeed OBJECT-TYPE
SYNTAX INTEGER {
autoDetect(1),
autoDetect10100(2),
-- Auto Detect with,
-- only allowed values: 10 & 100
s4000000(4000000), -- 4 Mbps
s10000000(10000000), -- 10 Mbps
s16000000(16000000), -- 16 Mbps
s45000000(45000000), -- 45 Mbps
s64000000(64000000), -- 64 Mbps
s100000000(100000000), -- 100 Mbps
s155000000(155000000), -- 155 Mbps
s400000000(400000000), -- 400 Mbps
s622000000(622000000), -- 622 Mbps
s1000000000(1000000000), -- 1 Gbps
s1544000(1544000), -- 1.544 Mbps
s2000000(2000000), -- 2 Mbps
s2048000(2048000), -- 2.048 Mbps
s64000(64000), -- 64 kps
s10G(10) -- 10 Gps
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The desired speed of the port.
The current operational speed of the port can be
determined from ifSpeed."
::= { portEntry 9 }
portDuplex OBJECT-TYPE
SYNTAX INTEGER {
half(1),
full(2),
disagree(3), -- read-only
auto(4) -- read-only
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Indicates whether the port is operating in half-
duplex, full-duplex, disagree or auto negotiation
mode. If the port could not agree with the far end
on port duplex, the port will be in disagree(3)
mode."
::= { portEntry 10 }
portIfIndex OBJECT-TYPE
SYNTAX INTEGER (1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The value of the instance of the ifIndex object,
defined in MIB-II, for the interface corresponding
to this port."
::= { portEntry 11 }
portSpantreeFastStart OBJECT-TYPE
SYNTAX INTEGER { enabled(1), disabled(2) }
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION "Indicates whether the port is operating in
spantree fast start mode. A port with fast start
enabled is immediately put in spanning tree
forwarding state on link up, rather than starting
in blocking state which is the normal operation.
This is useful when the port is known to be
connected to a single station which has problems
waiting for the normal spanning tree operation to
put the port in forwarding state.
This object is deprecated and replaced by
stpxFastStartPortTable in
CISCO-STP-EXTENSIONS-MIB."
DEFVAL { disabled }
::= { portEntry 12 }
portAdminRxFlowControl OBJECT-TYPE
SYNTAX INTEGER { on(1), off(2), desired(3) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Indicates the receive flow control administrative
status set on the port. If the status is set to
on(1), the port will require the far end to send
flow control. If the status is set to off(2), the
port will not allow far end to send flow control.
If the status is set to desired(3), the port will
allow the far end to send the flow control."
DEFVAL { off }
::= { portEntry 13}
portOperRxFlowControl OBJECT-TYPE
SYNTAX INTEGER { on(1), off(2), disagree(3) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the receive flow control operational
status of the port. If the port could not agree
with the far end on a link protocol, its
operational status will be disagree(3)."
::= { portEntry 14}
portAdminTxFlowControl OBJECT-TYPE
SYNTAX INTEGER { on(1), off(2), desired(3) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Indicates the transmit flow control
administrative status set on the port.
If the status is set to on(1), the port will send
flow control to the far end.
If the status is set to off(2), the port will not
send flow control to the far end. If the status is
set to desired(3), the port will send flow control
to the far end if the far end supports it."
::= { portEntry 15}
portOperTxFlowControl OBJECT-TYPE
SYNTAX INTEGER { on(1), off(2), disagree(3) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the transmit flow control operational
status of the port. If the port could not agree
with the far end on a link protocol, its
operational status will be disagree(3)."
::= { portEntry 16}
portMacControlTransmitFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The total number of MAC control frames passed to
the MAC sublayer for transmission."
::= { portEntry 17}
portMacControlReceiveFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The total number of MAC control frames passed by
the MAC sublayer to the MAC Control sublayer on
receive."
::= { portEntry 18}
portMacControlPauseTransmitFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The total number of PAUSE frames passed to
the MAC sublayer for transmission."
::= { portEntry 19}
portMacControlPauseReceiveFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The total number of PAUSE frames passed by
the MAC sublayer to the MAC Control sublayer
on receive."
::= { portEntry 20}
portMacControlUnknownProtocolFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The total number of MAC Control frames received
with an opcode that is not supported by the
device."
::= { portEntry 21}
portLinkFaultStatus OBJECT-TYPE
SYNTAX INTEGER {
noFault(1),
nearEndFault(2),
nearEndConfigFail(3),
farEndDisable(4),
farEndFault(5),
farEndConfigFail(6),
notApplicable(7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Specifies additional link fault status on a
gigabit link.
noFault:
Link is up and operational.
nearEndFault:
The port is enabled but there is no GBIC
present or the local port cannot
synchronize with the remote end.
nearEndConfigFail:
The local port has detected a
configuration mismatch with the remote
end.
farEndDisable:
The far end is in the disabled state.
farEndFault:
The remote port is cannot synchronize.
farEndConfigFail:
The remote port has detected a
configuration mismatch with the local end.
notApplicable:
Link fault status is not applicable on
this port."
::= { portEntry 22 }
portAdditionalOperStatus OBJECT-TYPE
SYNTAX BITS {
other(0), -- none of the following
connected(1),
standby(2),
faulty(3),
notConnected(4),
inactive(5),
shutdown(6),
dripDis(7),
disabled(8),
monitor(9),
errdisable(10),
linkFaulty(11),
onHook(12),
offHook(13),
reflector(14)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The current operational status of the port which
is showing additional detailed information of the
port."
::= { portEntry 23 }
portInlinePowerDetect OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicate if the port detects an inline power capable
device connected to it."
::= { portEntry 24 }
portEntPhysicalIndex OBJECT-TYPE
SYNTAX PhysicalIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The value of the instance of the entPhysicalIndex
object, defined in ENTITY-MIB, for the
entity physical index corresponding to this port."
::= { portEntry 25 }
portErrDisableTimeOutEnable OBJECT-TYPE
SYNTAX INTEGER { enabled(1), disabled(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Indicates whether a port that is put into
errdisable state by a cause as specified by
sysErrDisableTimeoutEnable will be re-enabled
automatically during the timeout interval as
specified by sysErrDisableTimeoutInterval."
DEFVAL { enabled }
::= { portEntry 26 }
-- the tftp group
-- Implementation of the tftp group is current for all Cisco Workgroup
-- Stack products which implement tftp upload/download functions.
tftpHost OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Name of source/destination host for the TFTP
transfer or storage device transfer. If the name
is for the TFTP transfer, it can be the IP
address or the host name. If the name for the
storage device transfer, it will be in the format
of deviceName: (e.g. slot0:, slot1:)."
::= { tftpGrp 1 }
tftpFile OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Name of file for the TFTP transfer or for storage
device transfer."
::= { tftpGrp 2 }
tftpModule OBJECT-TYPE
SYNTAX INTEGER (0..16)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Which module's code/configuration is being
transferred."
::= { tftpGrp 3 }
tftpAction OBJECT-TYPE
SYNTAX INTEGER {
other(1), -- none of the following
downloadConfig(2),
uploadConfig(3),
downloadSw(4),
uploadSw(5),
downloadFw(6),
uploadFw(7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Setting this object to one of the acceptable
values initiates the requested action using the
information given in tftpHost, tftpFile,
tftpModule.
downloadConfig(2): receive configuration from
host/file
uploadConfig(3) : send configuration to
host/file
downloadSw(4) : receive software image from
host/file
uploadSw(5) : send software image to
host/file
downloadFw(6) : receive firmware image from
host/file
uploadFw(7) : send firmware image to
host/file
Setting this object to any other value results in
an error."
::= { tftpGrp 4 }
tftpResult OBJECT-TYPE
SYNTAX INTEGER {
inProgress(1),
success(2),
noResponse(3),
tooManyRetries(4),
noBuffers(5),
noProcesses(6),
badChecksum(7),
badLength(8),
badFlash(9),
serverError(10),
userCanceled(11),
wrongCode(12),
fileNotFound(13),
invalidTftpHost(14),
invalidTftpModule(15),
accessViolation(16),
unknownStatus(17),
invalidStorageDevice(18),
insufficientSpaceOnStorageDevice(19),
insufficientDramSize(20),
incompatibleImage(21)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Contains result of the last tftp action request."
::= { tftpGrp 5 }
-- the brouter group
--Implementation of the brouter group is current for all Cisco Workgroup
--Stack products which implement combined bridging/routing functions.
brouterEnableRip OBJECT-TYPE
SYNTAX INTEGER { enabled(1), disabled(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Indicates whether the RIP protocol is enabled."
DEFVAL { enabled }
::= { brouterGrp 1 }
brouterEnableSpantree OBJECT-TYPE
SYNTAX INTEGER { enabled(1), disabled(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Indicates if Spanning Tree protocol is enabled."
DEFVAL { disabled }
::= { brouterGrp 2 }
brouterEnableGiantCheck OBJECT-TYPE
SYNTAX INTEGER { enabled(1), disabled(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Indicates whether special handling of giant
packets is enabled."
DEFVAL { disabled }
::= { brouterGrp 3 }
brouterEnableIpFragmentation OBJECT-TYPE
SYNTAX INTEGER { enabled(1), disabled(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Indicates whether IP fragmentation is enabled."
DEFVAL { enabled }
::= { brouterGrp 4 }
brouterEnableUnreachables OBJECT-TYPE
SYNTAX INTEGER { enabled(1), disabled(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Indicates whether ICMP unreachable messages are
sent by the system."
DEFVAL { enabled }
::= { brouterGrp 5 }
brouterCamAgingTime OBJECT-TYPE
SYNTAX INTEGER (0..1000000)
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION "The aging time for the CAM table. This duplicate
item is the same value as dot1dTpAgingTime."
DEFVAL { 300 }
::= { brouterGrp 6 }
brouterCamMode OBJECT-TYPE
SYNTAX INTEGER { filtering(1), forwarding(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Mode in which the CAM module is operating."
DEFVAL { filtering }
::= { brouterGrp 7 }
brouterIpxSnapToEther OBJECT-TYPE
SYNTAX INTEGER {
snap(1),
ethernetII(2),
iso8023(3),
raw8023(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The default translation for IPX packets when
bridging from FDDI SNAP to Ethernet."
DEFVAL { raw8023 }
::= { brouterGrp 8 }
brouterIpx8023RawToFddi OBJECT-TYPE
SYNTAX INTEGER {
snap(1),
iso8022(5),
fddiRaw(6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The default translation for IPX packets when
bridging from Ethernet 802.3 Raw to FDDI."
DEFVAL { snap }
::= { brouterGrp 9 }
brouterEthernetReceiveMax OBJECT-TYPE
SYNTAX INTEGER (1..100)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Maximum number of Ethernet receive buffers
processed at one time per port."
DEFVAL { 64 }
::= { brouterGrp 10 }
brouterEthernetTransmitMax OBJECT-TYPE
SYNTAX INTEGER (1..100)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Maximum number of Ethernet transmit buffers
processed at one time per port."
DEFVAL { 64 }
::= { brouterGrp 11 }
brouterFddiReceiveMax OBJECT-TYPE
SYNTAX INTEGER (1..512)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Maximum number of FDDI receive buffers processed
at one time per port."
DEFVAL { 256 }
::= { brouterGrp 12 }
brouterFddiTransmitMax OBJECT-TYPE
SYNTAX INTEGER (1..512)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Maximum number of FDDI transmit buffers processed
at one time per port."
DEFVAL { 256 }
::= { brouterGrp 13 }
-- the brouter port table
brouterPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF BrouterPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A list of brouter port entries. The number of
entries is determined by the number of modules in
the chassis and the number of ports on each
module."
::= { brouterGrp 14 }
brouterPortEntry OBJECT-TYPE
SYNTAX BrouterPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Entry containing bridge/router information for a
particular port on a module."
INDEX { brouterPortModule, brouterPort }
::= { brouterPortTable 1 }
BrouterPortEntry ::=
SEQUENCE {
brouterPortModule
INTEGER,
brouterPort
INTEGER,
brouterPortIpVlan
VlanIndex,
brouterPortIpAddr
IpAddress,
brouterPortNetMask
IpAddress,
brouterPortBroadcast
IpAddress,
brouterPortBridgeVlan
INTEGER,
brouterPortIpHelpers
OCTET STRING
}
brouterPortModule OBJECT-TYPE
SYNTAX INTEGER (1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "An index value that uniquely identifies the
module index where this port is located."
::= { brouterPortEntry 1 }
brouterPort OBJECT-TYPE
SYNTAX INTEGER (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "An index value that uniquely identifies this port
within a module (see portIndex)."
::= { brouterPortEntry 2 }
brouterPortIpVlan OBJECT-TYPE
SYNTAX VlanIndex
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The IP Virtual LAN to which this port belongs."
::= { brouterPortEntry 3 }
brouterPortIpAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION "This port's IP address."
::= { brouterPortEntry 4 }
brouterPortNetMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION "This port's subnet mask."
::= { brouterPortEntry 5 }
brouterPortBroadcast OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION "This port's broadcast address."
::= { brouterPortEntry 6 }
brouterPortBridgeVlan OBJECT-TYPE
SYNTAX INTEGER (0..1023)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The bridge Virtual LAN to which this port
belongs."
::= { brouterPortEntry 7 }
brouterPortIpHelpers OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..128))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "An indication of which other Virtual LANs UDP/IP
broadcasts received on this port will be forwarded
to. The normal situation is broadcasts NOT
forwarded beyond the originating VLAN, but it can
be useful in certain circumstances. This is an
octet string value with bits set to indicate
forwarded to VLANs. It can be interpreted as a sum
of f(x) as x goes from 0 to 1023, where f(x) = 0
for no forwarding to VLAN x and f(x) = exp(2, x)
for VLAN x forwarded to. If all bits are 0 or the
octet string is zero length, then UDP/IP
broadcasts are not being forwarded to other
VLANs."
::= { brouterPortEntry 8 }
-- additional brouter group objects
brouterIpx8022ToEther OBJECT-TYPE
SYNTAX INTEGER {
snap(1),
ethernetII(2),
iso8023(3),
raw8023(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The default translation for IPX packets when
bridging from FDDI 802.2 to Ethernet."
DEFVAL { iso8023 }
::= { brouterGrp 15 }
brouterEnableTransitEncapsulation OBJECT-TYPE
SYNTAX INTEGER { enabled(1), disabled(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Indicates whether Ethernet packets are
encapsulated on FDDI via transit encapsulation
protocol. Normally this option would be disabled
to allow translational bridging between Ethernet
and FDDI to take place."
DEFVAL { disabled }
::= { brouterGrp 16 }
brouterEnableFddiCheck OBJECT-TYPE
SYNTAX INTEGER { enabled(1), disabled(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Indicates whether MAC addresses learned one side
of a translational bridge should not be allowed to
be learned on the other side of the bridge. The
presence certain misbehaving devices on the
network may require this option to be enabled."
DEFVAL { disabled }
::= { brouterGrp 17 }
brouterEnableAPaRT OBJECT-TYPE
SYNTAX INTEGER { enabled(1), disabled(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Indicates whether the Automatic Packet
Recognition and Translation feature is enabled on
translational bridge(s) in the box. If APaRT is
disabled, the default translations as defined by
the objects brouterIpx8022ToEther,
brouterIpx8023RawToFddi, brouterIpxSnapToEther,
etc, are used on all packets and no automatic
learning of translation information is performed."
DEFVAL { enabled }
::= { brouterGrp 18 }
-- the filter group
-- Implementation of the filter group is current for all Cisco Workgroup
-- Stack products which implement custom packet filtering functions.
-- the filter mac table
filterMacTable OBJECT-TYPE
SYNTAX SEQUENCE OF FilterMacEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A list of filter mac entries."
::= { filterGrp 1 }
filterMacEntry OBJECT-TYPE
SYNTAX FilterMacEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Entry containing MAC address filter information."
INDEX { filterMacModule, filterMacPort,
filterMacAddress }
::= { filterMacTable 1 }
FilterMacEntry ::=
SEQUENCE {
filterMacModule
INTEGER,
filterMacPort
INTEGER,
filterMacAddress
MacAddress,
filterMacType
INTEGER
}
filterMacModule OBJECT-TYPE
SYNTAX INTEGER (1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "An index value that uniquely identifies the
module where this port is located
(see portModuleIndex)."
::= { filterMacEntry 1 }
filterMacPort OBJECT-TYPE
SYNTAX INTEGER (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "An index value that uniquely identifies this port
within a module (see portIndex)."
::= { filterMacEntry 2 }
filterMacAddress OBJECT-TYPE
SYNTAX MacAddress -- OCTET STRING (SIZE (6))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A MAC address. If the source or destination MAC
address equals this value, a match occurs. The
packet is dropped if a match occurs and deny(1)
was specified. The packet is dropped if a match
doesn't occur and at least one MAC address filter
was specified with permit(3)."
::= { filterMacEntry 3 }
filterMacType OBJECT-TYPE
SYNTAX INTEGER {
deny(1), -- add deny entry
invalid(2), -- remove this entry
permit(3), -- add permit entry
permitSrc(4), -- add permit source entry
permitDst(5), -- add permit dest entry
denySrc(6), -- add deny source entry
denyDst(7), -- add deny dest entry
denySrcLearn(8) -- add deny source learn entry
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Setting this object to invalid(2) removes the
corresponding entry from the filterMacTable.
To add a new entry to the filterMacTable, set this
object to deny(1) or any value from permit(3) to
denySrcLearn(8) for a module, port, and MAC
address not already in the table."
::= { filterMacEntry 4 }
-- the filter vendor table
filterVendorTable OBJECT-TYPE
SYNTAX SEQUENCE OF FilterVendorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A list of filter vendor ID entries."
::= { filterGrp 2 }
filterVendorEntry OBJECT-TYPE
SYNTAX FilterVendorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Entry containing vendor ID filter information."
INDEX { filterVendorModule, filterVendorPort,
filterVendorId }
::= { filterVendorTable 1 }
FilterVendorEntry ::=
SEQUENCE {
filterVendorModule
INTEGER,
filterVendorPort
INTEGER,
filterVendorId
VendorIdType,
filterVendorType
INTEGER
}
filterVendorModule OBJECT-TYPE
SYNTAX INTEGER (1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "An index value that uniquely identifies the
module where this port is located
(see portModuleIndex)."
::= { filterVendorEntry 1 }
filterVendorPort OBJECT-TYPE
SYNTAX INTEGER (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "An index value that uniquely identifies this port
within a module (see portIndex)."
::= { filterVendorEntry 2 }
filterVendorId OBJECT-TYPE
SYNTAX VendorIdType -- OCTET STRING (SIZE (3))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The vendor ID portion of a MAC address. If the
source or destination MAC address has the same
vendor ID, a match occurs. The packet is dropped
if a match occurs and deny(1) was specified. The
packet is dropped if a match doesn't occur and at
least one Vendor ID filter was specified with
permit(3)."
::= { filterVendorEntry 3 }
filterVendorType OBJECT-TYPE
SYNTAX INTEGER {
deny(1), -- add deny entry
invalid(2), -- remove this entry
permit(3) -- add permit entry
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Setting this object to invalid(2) removes the
corresponding entry from the filterVendorTable.
To add a new entry to the filterVendorTable, set
this object to deny(1) or permit(3) for a module,
port, and vendor ID not already in the table."
::= { filterVendorEntry 4 }
-- the filter protocol table
filterProtocolTable OBJECT-TYPE
SYNTAX SEQUENCE OF FilterProtocolEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A list of filter protocol entries."
::= { filterGrp 3 }
filterProtocolEntry OBJECT-TYPE
SYNTAX FilterProtocolEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Entry containing PROTOCOL address filter
information."
INDEX { filterProtocolModule, filterProtocolPort,
filterProtocolValue }
::= { filterProtocolTable 1 }
FilterProtocolEntry ::=
SEQUENCE {
filterProtocolModule
INTEGER,
filterProtocolPort
INTEGER,
filterProtocolValue
INTEGER,
filterProtocolType
INTEGER
}
filterProtocolModule OBJECT-TYPE
SYNTAX INTEGER (1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "An index value that uniquely identifies the
module where this port is located
(see portModuleIndex)."
::= { filterProtocolEntry 1 }
filterProtocolPort OBJECT-TYPE
SYNTAX INTEGER (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "An index value that uniquely identifies this port
within a module (see portIndex)."
::= { filterProtocolEntry 2 }
filterProtocolValue OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A 16-bit protocol value. If the packet's type
field or the packet's DSAP/SSAP field is equal to
this value, a match occurs. The packet is dropped
if a match occurs and deny(1) was specified. The
packet is dropped if a match doesn't occur and at
least one protocol type filter was specified with
permit(3)."
::= { filterProtocolEntry 3 }
filterProtocolType OBJECT-TYPE
SYNTAX INTEGER {
deny(1), -- add deny entry
invalid(2), -- remove this entry
permit(3) -- add permit entry
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Setting this object to invalid(2) removes the
corresponding entry from the filterProtocolTable.
To add a new entry to the filterProtocolTable, set
this object to deny(1) or permit(3) for a module,
port, and protocol value not already in the
table."
::= { filterProtocolEntry 4 }
-- the filter test table
filterTestTable OBJECT-TYPE
SYNTAX SEQUENCE OF FilterTestEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A list of filter test entries."
::= { filterGrp 4 }
filterTestEntry OBJECT-TYPE
SYNTAX FilterTestEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Entry containing test filter information."
INDEX { filterTestModule, filterTestPort,
filterTestIndex }
::= { filterTestTable 1 }
FilterTestEntry ::=
SEQUENCE {
filterTestModule
INTEGER,
filterTestPort
INTEGER,
filterTestIndex
INTEGER,
filterTestType
INTEGER,
filterTestOffset
INTEGER,
filterTestValue
INTEGER,
filterTestMask
INTEGER
}
filterTestModule OBJECT-TYPE
SYNTAX INTEGER (1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "An index value that uniquely identifies the
module where this port is located
(see portModuleIndex)."
::= { filterTestEntry 1 }
filterTestPort OBJECT-TYPE
SYNTAX INTEGER (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "An index value that uniquely identifies this port
within a module (see portIndex)."
::= { filterTestEntry 2 }
filterTestIndex OBJECT-TYPE
SYNTAX INTEGER (1..8)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "An index value that uniquely identifies a test
for a particular module/port."
::= { filterTestEntry 3 }
filterTestType OBJECT-TYPE
SYNTAX INTEGER {
valid(1), -- add this entry
invalid(2) -- remove this entry
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Setting this object to invalid(2) removes the
corresponding entry from the filterTestTable. To
add a new entry to the filterTestTable, set this
object to valid(1) for a module, port, and test
index not already in the table."
::= { filterTestEntry 4 }
filterTestOffset OBJECT-TYPE
SYNTAX INTEGER (0..4500)
MAX-ACCESS read-create
STATUS current
DESCRIPTION "A byte offset into packet. Must be a 32-bit word
aligned offset, i.e. 0, 4, 8, etc."
::= { filterTestEntry 5 }
filterTestValue OBJECT-TYPE
SYNTAX INTEGER (0..2147483647)
MAX-ACCESS read-create
STATUS current
DESCRIPTION "A 32-bit value to be compared against the packet
location specified by filterTestOffset."
::= { filterTestEntry 6 }
filterTestMask OBJECT-TYPE
SYNTAX INTEGER (0..2147483647)
MAX-ACCESS read-create
STATUS current
DESCRIPTION "A 32-bit value to be bitwise ANDed with the
packet location specified by filterTestOffset
before being compared to filterTestValue."
::= { filterTestEntry 7 }
-- the filter port table
filterPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF FilterPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A list of filter port entries. The number of
entries is determined by the number of modules in
the chassis and the number of ports on each
module."
::= { filterGrp 5 }
filterPortEntry OBJECT-TYPE
SYNTAX FilterPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Entry containing filter information for a
particular port on a module."
INDEX { filterPortModule, filterPort }
::= { filterPortTable 1 }
FilterPortEntry ::=
SEQUENCE {
filterPortModule
INTEGER,
filterPort
INTEGER,
filterPortComplex
DisplayString,
filterPortBroadcastThrottle
INTEGER,
filterPortBroadcastThreshold
INTEGER,
filterPortBroadcastDiscards
Counter32,
filterPortBroadcastThresholdFraction
INTEGER,
filterPortSuppressionOption
BITS,
filterPortSuppressionViolation
INTEGER
}
filterPortModule OBJECT-TYPE
SYNTAX INTEGER (1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "An index value that uniquely identifies the
module where this port is located
(see portModuleIndex)."
::= { filterPortEntry 1 }
filterPort OBJECT-TYPE
SYNTAX INTEGER (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "An index value that uniquely identifies this port
within a module (see portIndex)."
::= { filterPortEntry 2 }
filterPortComplex OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..50))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "A complex expression made up of the numbers 1
through 8 indicating test results from
filterTestIndex and using logical operators '&'
(and), '|' (or), '!' (not), and parenthesis. For
example: ((1 & 2) | !3). If this complex filter
matches a packet, it is dropped."
::= { filterPortEntry 3 }
filterPortBroadcastThrottle OBJECT-TYPE
SYNTAX INTEGER (0..150000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The maximum number of broadcast packets per
second allowed on this port. If the number of
incoming broadcast packets in a one second
interval exceeds this amount, packets are
dropped for the rest of the interval. If the
capability exists, only broadcast packets should
be dropped. Otherwise, all packets are dropped
during the suppression interval.
A value of 0 indicates broadcast packets should
not be limited.
The ability to suppress broadcast packets in this
manner exists only on certain ports. If it does
not exist on this port, attempts to write a value
other than 0 are rejected.
This object also applies to multicast (and/or)
unicast suppression when
filterPortSuppressionOption is enabled."
DEFVAL { 0 }
::= { filterPortEntry 4 }
filterPortBroadcastThreshold OBJECT-TYPE
SYNTAX INTEGER (0..100)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Indicates the integer part of the maximum
percentage of available bandwidth allowed for
incoming traffic of the specific traffic types on
this port. The associated object
filterPortBroadcastThresholdFraction indicates the
fraction part of the maximum percentage of
available bandwidth allowed for incoming traffic
of the specific traffic types on this port. Either
packets of the specific traffic types are dropped
of the port is put into errdisable state depending
on the value of filterPortSuppressionViolation on
this port if the percentage of incoming traffic of
the specific traffic types would exceed this
limit. The traffic types that are enabled for
this traffic suppression feature is indicated by
filterPortBroadcastOption.
The maximum percentage for the combination of this
object value and the object value of
filterPortBroadcastThresholdFraction is 100.00
which indicates traffic of all traffic types
should not be limited.
The ability to suppress traffic in this manner
exists only on certain ports. If it does not
exist on this port, attempts to write a value of
this object other than 100 are rejected.
On platforms where filterPortSuppressionOption
object is not supported, this object only applies
to broadcast suppression."
DEFVAL { 100 }
::= { filterPortEntry 5 }
filterPortBroadcastDiscards OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The number of packets discarded due to traffic
suppression on this port."
::= { filterPortEntry 6 }
filterPortBroadcastThresholdFraction OBJECT-TYPE
SYNTAX INTEGER (0..99)
UNITS "one-hundredths"
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Indicates the fraction part of the maximum
percentage of available bandwidth allowed for
incoming traffic of the specific traffic types on
this port. The associated object
filterPortBroadcastThreshold indicates the integer
part of the maximum percentage of available
bandwidth allowed for incoming traffic of the
specific traffic types on this port. Either
packets of the specific traffic types are dropped
or the port is put into errdisable state
depending on the value of
filterPortSuppressionViolation on this port if the
percentage of incoming traffic of the specific
traffic type would exceed this limit. The
traffic types that are enabled for this traffic
suppression feature is indicated by
filterPortBroadcastOption.
The maximum percentage for the combination
of this object value and the object value of
filterPortBroadcastThreshold is 100.00 which
indicates traffic of all traffic types should not
be limited.
The ability to suppress traffic in this manner
exists only on certain ports. If it does not exist
on this port, attempts to write a value of this
object other than 100 are rejected.
On platforms where filterPortSuppressionOption
object is not supported, this object only applies
to broadcast suppression."
DEFVAL { 0 }
::= { filterPortEntry 7 }
filterPortSuppressionOption OBJECT-TYPE
-- SYNTAX OCTET STRING
SYNTAX BITS {
multicast(0),
unicast(1),
broadcast(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Indicates the traffic types that traffic
suppression feature is enabled for.
multicast(0) is set when multicast suppression is
enabled. unicast(1) is set when unicast
suppression is enabled. broadcast(2) is set when
broadcast suppression is enabled."
::= { filterPortEntry 8 }
filterPortSuppressionViolation OBJECT-TYPE
SYNTAX INTEGER {
dropPackets(1),
errdisable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Indicates the action that will be taken on this
port when the percentage of either broadcast,
multicast or unicast traffic exceeds the limit as
indicated by filterPortBroadcastThreshold and
filterPortBroadcastThresholdFraction.
dropPackets - the excessive packets will be
- dropped on this port.
errdisable - the port will be put into errdisable
- state.
The object is only supported on platforms that
support this suppression violation action
feature."
::= { filterPortEntry 9 }
-- the monitor group
-- Implementation of the monitor group is current for all Cisco
-- Workgroup Stack products which implement port monitoring functions.
--
-- The monitorGrp is deprecated and replaced by
-- portCopyTable defined in SMON-MIB.
monitorSourceModule OBJECT-TYPE
SYNTAX INTEGER (0..16)
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION "An index value that uniquely identifies the
module where the monitoring source port is
located. A value of 0 indicates that the
monitorSourcePort is really a source Virtual LAN
number. To monitor multiple source ports, this
object should be set to 0 and
monitorAdminSourcePorts should be configured."
::= { monitorGrp 1 }
monitorSourcePort OBJECT-TYPE
SYNTAX INTEGER (0..1023)
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION "An index value that uniquely identifies the
monitoring source port within a module or the
monitoring source Virtual LAN. To monitor multiple
source ports, this object should be set to 0 and
monitorAdminSourcePorts should be configured"
::= { monitorGrp 2 }
monitorDestinationModule OBJECT-TYPE
SYNTAX INTEGER (1..16)
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION "An index value that uniquely identifies the
module where the monitoring destination port is
located."
::= { monitorGrp 3 }
monitorDestinationPort OBJECT-TYPE
SYNTAX INTEGER (1..255)
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION "An index value that uniquely identifies the
monitoring destination port within a module."
::= { monitorGrp 4 }
monitorDirection OBJECT-TYPE
SYNTAX INTEGER {
transmit(1),
receive(2),
transmitAndReceive(3)
}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION "The type of packets to be monitored at the source
port."
DEFVAL { transmitAndReceive }
::= { monitorGrp 5 }
monitorEnable OBJECT-TYPE
SYNTAX INTEGER { enabled(1), disabled(2) }
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION "Indicates whether port monitoring is in
progress."
DEFVAL { disabled }
::= { monitorGrp 6 }
monitorAdminSourcePorts OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..128))
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION "Indicates the administrative status of which
ports are monitored. All the monitored ports have
to be non-trunking port and belong to the same
Virtual LAN. The octet string contains one bit
per port. Each bit within the octet string
represents one port of the device. The ordering
of ports represented within the octet string is
in the same order as in the RFC 1493
dot1dStpPortTable.
The bit value interpretation is as follows:
1 = being monitored
0 = not being monitored"
::= { monitorGrp 7 }
monitorOperSourcePorts OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..128))
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "Indicates which ports are actually being
monitored. All the monitored ports have to be
non-trunking port and belong to the same Virtual
LAN. The octet string contains one bit per port.
Each bit within the octet string represents one
port of the device. The ordering of ports
represented within the octet string is in the same
order as in the RFC 1493 dot1dStpPortTable.
The bit value interpretation is as follows:
1 = being monitored
0 = not being monitored"
::= { monitorGrp 8 }
-- the VLAN group
-- the vlan table
vlanTable OBJECT-TYPE
SYNTAX SEQUENCE OF VlanEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION "A list of Virtual LAN entries. The number of
entries is determined by the number of VLANs
supported by the system."
::= { vlanGrp 2 }
vlanEntry OBJECT-TYPE
SYNTAX VlanEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION "Entry containing information for a particular
Virtual LAN."
INDEX { vlanIndex }
::= { vlanTable 1 }
VlanEntry ::=
SEQUENCE {
vlanIndex
VlanIndex,
vlanSpantreeEnable
INTEGER,
vlanIfIndex
INTEGER
}
vlanIndex OBJECT-TYPE
SYNTAX VlanIndex
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "An index value that uniquely identifies the
Virtual LAN associated with this information."
::= { vlanEntry 1 }
vlanSpantreeEnable OBJECT-TYPE
SYNTAX INTEGER { enabled(1), disabled(2),
notApplicable(3) }
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION "Indicates whether Spanning Tree protocol is
enabled for this Virtual LAN.
If the device only supports a single global
Spanning Tree PVST+ Protocol enable/disable
for all the existing VLANs, then the object
value assigned to this VLAN will be applied
to the object values of all the instances
in this table which do not have the value
of notApplicable(3).
This object is deprecated and replaced by
stpxPVSTVlanEnable in
CISCO-STP-EXTENSIONS-MIB."
DEFVAL { enabled }
::= { vlanEntry 2 }
vlanIfIndex OBJECT-TYPE
SYNTAX INTEGER (1..2147483647)
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "The value of the ifIndex object defined in
MIB-II, for the interface corresponding to this
VLAN.
This object is deprecated and replaced by
vtpVlanIfIndex in CISCO-VTP-MIB."
::= { vlanEntry 3 }
-- the vlan port table
vlanPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF VlanPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A list of Virtual LAN port entries. The number of
entries is determined by the number of modules in
the chassis and the number of ports on each
module."
::= { vlanGrp 3 }
vlanPortEntry OBJECT-TYPE
SYNTAX VlanPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Entry containing Virtual LAN information for a
particular port on a module."
INDEX { vlanPortModule, vlanPort }
::= { vlanPortTable 1 }
VlanPortEntry ::=
SEQUENCE {
vlanPortModule
INTEGER,
vlanPort
INTEGER,
vlanPortVlan
VlanIndex,
vlanPortIslVlansAllowed
OCTET STRING,
vlanPortSwitchLevel
INTEGER,
vlanPortIslAdminStatus
INTEGER,
vlanPortIslOperStatus
INTEGER,
vlanPortIslPriorityVlans
OCTET STRING,
vlanPortAdminStatus
INTEGER,
vlanPortOperStatus
INTEGER,
vlanPortAuxiliaryVlan
INTEGER
}
vlanPortModule OBJECT-TYPE
SYNTAX INTEGER (1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "An index value that uniquely identifies the
module where this port is located
(see portModuleIndex)."
::= { vlanPortEntry 1 }
vlanPort OBJECT-TYPE
SYNTAX INTEGER (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "An index value that uniquely identifies this port
within a module (see portIndex)."
::= { vlanPortEntry 2 }
vlanPortVlan OBJECT-TYPE
SYNTAX VlanIndex
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The Virtual LAN to which this port belongs."
::= { vlanPortEntry 3 }
-- vlanPortEntry 4 is not used
vlanPortIslVlansAllowed OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..128))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "An indication of which Virtual LANs are allowed
on this Inter-Switch Link. This is an octet string
value with bits set to indicate allowed VLANs. It
can be interpreted as a sum of f(x) as x goes from
0 to 1023, where f(x) = 0 for VLAN x not allowed
and f(x) = exp(2, x) for VLAN x allowed."
::= { vlanPortEntry 5 }
vlanPortSwitchLevel OBJECT-TYPE
SYNTAX INTEGER { normal(1), high(2), notApplicable(3) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Indicates the priority level the port uses to
access the switching media. If vlanPortSwitchLevel
is not applicable to the port, notApplicable(3)
will be returned by the device."
DEFVAL { normal }
::= { vlanPortEntry 6 }
vlanPortIslAdminStatus OBJECT-TYPE
SYNTAX INTEGER { on(1), off(2), desirable(3), auto(4),
onNoNegotiate(5) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Indicates the administrative status set on the
trunk port while the operational status is the one
that indicates whether the port is actually
trunking or not. If the status is set to off(2),
the port is permanently set to be a non-trunk. If
the status is set to onNoNegotiate(5), the port is
permanently set to be a trunk and no negotiation
takes place with the far end to try to ensure
consistent operation. If the status is set to
on(1), the port initiates a request to become a
trunk and will become a trunk regardless of the
response from the far end. If the status is set to
desirable(3), the port initiates a request to
become a trunk and will become a trunk if the far
end agrees. If the status is set to auto(4), the
port does not initiate a request to become a trunk
but will do so if it receives a request to become
a trunk from the far end."
::= { vlanPortEntry 7 }
vlanPortIslOperStatus OBJECT-TYPE
SYNTAX INTEGER { trunking(1), notTrunking(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates if the port is actually trunking or
not. In the case of ISL capable ports, the status
depends on the success or failure of the
negotiation process initiated by the port to
become a trunk or non trunk.
In the case of 802.10 capable ports, it is
directly related to the on/off administrative
status."
::= { vlanPortEntry 8 }
vlanPortIslPriorityVlans OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..128))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "An indication of which Virtual LANs have a better
dot1dStpPortPriority value. This object can be
used to perform load balancing on Inter-Switch
Links via spanning tree. An Inter-Switch Link has
two dot1dStpPortPriority values which are shared
by all the Virtual LANs on the link. The Virtual
LANs indicated by this object have priority
over the other Virtual LANs on the link.
This is an octet string value with bits set to
indicate priority VLANs. It can be interpreted as
a sum of f(x) as x goes from 0 to 1023, where
f(x) = 0 for a VLAN x which does not have priority
and f(x) = exp(2, x) for a VLAN x which has
priority.
Setting the dot1dStpPortPriority value for any of
the Virtual LANs indicated by this object causes
the dot1dStpPortPriority value for all the Virtual
LANs indicated by this object to be set to the
same value.
Setting the dot1dStpPortPriority value for any
other Virtual LAN causes the dot1dStpPortPriority
value for all other Virtual LANs to be set to the
same value."
::= { vlanPortEntry 9 }
vlanPortAdminStatus OBJECT-TYPE
SYNTAX INTEGER { static(1), dynamic(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Indicates whether the port will get assigned to a
VLAN statically or dynamically. When it is set to
dynamic, the needed information will be accessed
from one of the Vlan Membership Policy Servers
specified in the vmpsTable. Default value is
static(1).
Note that vlanPortAdminStatus cannot be set to
dynamic(2) for a port which has
portSecurityAdminStatus set to enabled(1) or for a
port which currently has a vlanPortIslOperStatus
of trunking(1)."
DEFVAL { static }
::= { vlanPortEntry 10 }
vlanPortOperStatus OBJECT-TYPE
SYNTAX INTEGER { inactive(1),
active(2),
shutdown(3),
vlanActiveFault(4) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION "An indication of the current VLAN status of the
port.
A status of inactive(1) indicates that a dynamic
port does not yet have a VLAN assigned or that a
static or dynamic port has been assigned a VLAN
that is not currently active. A status of
active(2) indicates that the currently assigned
VLAN is active. A status of shutdown(3) indicates
that the port has been shutdown as a result of a
VMPS response on a dynamic port.
A status of vlanActiveFault(4) only applies to
tokenring ports and indicates that the port is
operationally disabled because the TR-CRF VLAN of
which the port is a member has active ports on
another device and only ports on that remote
device may participate in that TR-CRF VLAN."
::= { vlanPortEntry 11 }
vlanPortAuxiliaryVlan OBJECT-TYPE
SYNTAX INTEGER ( 0|1..1000|1025..4094|4095|4096 )
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION "The Voice Virtual Vlan ID (VVID) to which this
port belongs to.
If the VVID is not supported on the port, this MIB
object will not be configurable and will return
4096.
Setting this MIB object to 4096, the CDP packets
transmitting through this port would not include
Appliance VLAN-ID TLV.
Setting this MIB object to 4095, the CDP packets
transmitting through this port would contain
Appliance VLAN-ID TLV with value of 4095 - VoIP
and related packets are expected to be sent and
received untagged without an 802.1p priority.
Setting this MIB object to 0, the CDP packets
transmitting through this port would contain
Appliance VLAN-ID TLV with value of 0 - VoIP
and related packets are expected to be sent and
received with VLAN-id=0 and an 802.1p priority.
Setting this MIB object to N (1..1000|1025..4094),
the CDP packets transmitting through this port
would contain Appliance VLAN-ID TLV with N - VoIP
and related packets are expected to be sent and
received with VLAN-id=N and an 802.1p priority.
This object is deprecated and replaced by
vmVoiceVlanId in CISCO-VLAN-MEMBERSHIP-MIB."
::= { vlanPortEntry 12 }
-- the Vlan Membership Policy Server table
vmpsTable OBJECT-TYPE
SYNTAX SEQUENCE OF VmpsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table lists a maximum of 3 IP addresses of
Vlan Membership Policy Servers."
::= { vlanGrp 4 }
vmpsEntry OBJECT-TYPE
SYNTAX VmpsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A VMPS table entry."
INDEX { vmpsAddr }
::= { vmpsTable 1 }
VmpsEntry ::=
SEQUENCE {
vmpsAddr
IpAddress,
vmpsType
INTEGER
}
vmpsAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The IP address of a Vlan Membership Policy
Server. To configure the internal VMPS, use the
same IP address as specified in sysIpAddr."
::= { vmpsEntry 1 }
vmpsType OBJECT-TYPE
SYNTAX INTEGER {
invalid(1), -- remove this entry
primary(2), -- the primary entry
other(3) -- a lower priority entry
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION "To add a new entry to the vmpsTable, set this
object to primary(2) or other(3) for an IP address
which is not already in the table. The primary
entry will be used first, if it is reachable.
Otherwise one of the other entries will be used.
Setting one entry to primary(2) causes any
previous primary entry to change to other(3).
To remove an entry from the table, set this
object to invalid(1)."
::= { vmpsEntry 2 }
vmpsAction OBJECT-TYPE
SYNTAX INTEGER {
other(1), -- none of following (read-only)
inProgress(2), -- (read-only)
success(3), -- (read-only)
noResponse(4), -- (read-only)
noPrimaryVmps(5), -- No VMPS configured (read-only)
noDynamicPort(6), -- No dynamic ports configured
-- (read-only)
noHostConnected(7), -- No hosts on dynamic ports
-- (read-only)
reconfirm(8) -- (write-only)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "This object, when read, returns the result of the
last action requested: other(1), inProgress(2),
success(3), noResponse(3), noPrimaryVmps(5),
noDynamicPort(6), or noHostConnected(7).
Setting this object to reconfirm(8) causes the
switch to contact the Vlan Membership Policy
Server immediately to reconfirm the current VLAN
assignments for all dynamic ports on the switch.
Normally VLAN assignments for dynamic ports are
reconfirmed once an hour."
::= { vlanGrp 5 }
vmpsAccessed OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The IP address of the last Vlan Membership Policy
Server accessed. If there was no response from the
last VMPS request, the value returned is 0."
::= { vlanGrp 6 }
-- trunk VLAN mapping table
vlanTrunkMappingMax OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
UNITS "entries"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Maximum number of active configurable trunk VLAN
mapping entries allowed. A value of zero indicates
no limitation on the number of active configurable
trunk VLAN mapping."
::= { vlanGrp 7 }
vlanTrunkMappingTable OBJECT-TYPE
SYNTAX SEQUENCE OF VlanTrunkMappingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table contains zero or more rows of trunk
VLAN to VLAN associations. The maximum number of
active entries is determined by
vlanTrunkMappingMax.
VLAN above 1k can not be created if the value of
corresponding instance of vlanTrunkMappingType is
dot1qToisl(2)."
::= { vlanGrp 8 }
vlanTrunkMappingEntry OBJECT-TYPE
SYNTAX VlanTrunkMappingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Information about the VLAN mapping of a
particular trunk VLAN to another VLAN."
INDEX { vlanTrunkMappingFromVlan }
::= { vlanTrunkMappingTable 1 }
VlanTrunkMappingEntry ::=
SEQUENCE {
vlanTrunkMappingFromVlan VlanIndex,
vlanTrunkMappingToVlan VlanIndex,
vlanTrunkMappingType INTEGER,
vlanTrunkMappingOper TruthValue,
vlanTrunkMappingStatus RowStatus
}
vlanTrunkMappingFromVlan OBJECT-TYPE
SYNTAX VlanIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The VLAN with this VLAN ID will be mapped to the
VLAN in the corresponding instance of
vlanTrunkMappingToVlan in the device.
Agent returns inconsistentValue if this VLAN
exists in the device.
Agent returns inconsistentValue if this VLAN is
not a reserved VLAN and the value of corresponding
instance of vlanTrunkMappingType is
reservedToNonReserved(1).
Agent returns wrongValue if this VLAN is not a
valid 802.1Q VLAN and the value of corresponding
instance of vlanTrunkMappingType is
dot1qToisl(2)."
::= { vlanTrunkMappingEntry 1 }
vlanTrunkMappingToVlan OBJECT-TYPE
SYNTAX VlanIndex
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The VLAN which the corresponding instance of
vlanTrunkMappingFromVlan will be mapped to.
Agent returns inconsistentValue if this VLAN
exists in the device.
Agent returns inconsistentValue if this VLAN is a
reserved VLAN and the value of corresponding
instance of vlanTrunkMappingType is
reservedToNonReserved(1).
Agent returns inconsistentValue if this VLAN is
not a valid ISL VLAN and the value of
corresponding instance of vlanTrunkMappingType
is dot1qToisl(2)."
::= { vlanTrunkMappingEntry 2 }
vlanTrunkMappingType OBJECT-TYPE
SYNTAX INTEGER {
reservedToNonReserved(1),
dot1qToisl(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The type of this trunk VLAN mapping.
reservedToNonReserved(1)
An user defined association which maps a
reserved VLAN to a non-reserved VLAN.
dot1qToisl(2)
An user defined association which maps a VLAN
in 802.1q trunk to a VLAN in ISL trunk.
Implementations are allowed to restrict the
available types for this object.
For devices which support the range of VlanIndex
between 1024 and 4095, the default value is
reservedToNonReserved(1). The default value is
dot1qToisl(2) for devices which do not support the
range of VlanIndex between 1024 and 4095."
::= { vlanTrunkMappingEntry 3 }
vlanTrunkMappingOper OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates whether this VLAN mapping is effective
or not."
::= { vlanTrunkMappingEntry 4 }
vlanTrunkMappingStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The status of this trunk VLAN mapping.
Once a row becomes active, value in any other
column within such row cannot be modified except
by setting vlanTrunkMappingStatus to
notInService(2) for such row."
::= { vlanTrunkMappingEntry 5 }
-- the security group
-- Implementation of the security group is optional, but within the
-- group all the elements are current. If the Security feature is
-- implemented, the entire group should be implemented.
-- the port security table
portSecurityTable OBJECT-TYPE
SYNTAX SEQUENCE OF PortSecurityEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A list of port security entries. The number of
entries is determined by the number of ports in
the system which support the Security feature."
::= { securityGrp 1 }
portSecurityEntry OBJECT-TYPE
SYNTAX PortSecurityEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Entry containing security information for a
particular port."
INDEX { portSecurityModuleIndex, portSecurityPortIndex }
::= { portSecurityTable 1 }
PortSecurityEntry ::=
SEQUENCE {
portSecurityModuleIndex
INTEGER,
portSecurityPortIndex
INTEGER,
portSecurityAdminStatus
INTEGER,
portSecurityOperStatus
INTEGER,
portSecurityLastSrcAddr
OCTET STRING,
portSecuritySecureSrcAddr
OCTET STRING,
portSecurityMaxSrcAddr
INTEGER,
portSecurityAgingTime
INTEGER,
portSecurityShutdownTimeOut
INTEGER,
portSecurityViolationPolicy
INTEGER
}
portSecurityModuleIndex OBJECT-TYPE
SYNTAX INTEGER (1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "An index value that uniquely identifies the
module where this port is located
(see portModuleIndex)."
::= { portSecurityEntry 1 }
portSecurityPortIndex OBJECT-TYPE
SYNTAX INTEGER (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "An index value that uniquely identifies this port
within a module (see portIndex)."
::= { portSecurityEntry 2 }
portSecurityAdminStatus OBJECT-TYPE
SYNTAX INTEGER { enabled(1), disabled(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "When security is enabled, source MAC addresses
are monitored for all packets received on the
port. If an address is detected that does not
match the portSecuritySecureSrcAddr and any
corresponding portSecurityExtSecureSrcAddr, of
which portSecurityExtModuleIndex and
portSecurityExtPortIndex in the
portSecurityExtTable is the same as the
portSecurityModuleIndex and portSecurityPortIndex,
and the number of MAC address learned or
configured for this port is equal to
portSecurityMaxSrcAddr, the port will shutdown or
drop packets. If the
portSecurityViolationPolicy is set to shutdown(2),
the port is shutdown and a linkDown trap is sent;
otherwise the port drops the invalid packets."
DEFVAL { disabled }
::= { portSecurityEntry 3 }
portSecurityOperStatus OBJECT-TYPE
SYNTAX INTEGER { notShutdown(1), shutdown(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION "An indication of whether the port has been shut
down as a result of an insecure address being
detected on a secure port."
::= { portSecurityEntry 4 }
portSecurityLastSrcAddr OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (6))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The last source MAC address in a receive packet
seen on the port."
::= { portSecurityEntry 5 }
portSecuritySecureSrcAddr OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (6))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The address to be compared with source MAC
addresses of received packets when the
portSecurityAdminStatus is enabled(1). Setting
this value to 0.0.0.0.0.0 puts the port in
learning mode so that the next source MAC
address received by the port becomes the
portSecuritySecureSrcAddr."
::= { portSecurityEntry 6 }
portSecurityMaxSrcAddr OBJECT-TYPE
SYNTAX INTEGER(1..1025)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The maximum number (N) of MAC address to be
secured on the port. The first N MAC addresses
learned or configured are made secured. If the
user wants to make the port secured for more than
one MAC address, the portSecurityExtTable is used
in addition to portSecuritySecureSrcAddr. If
changing the maximum number N of Mac address to M,
which is smaller than N, some MAC addresses are
removed. Setting this value to 1,
the portSecurityExtTable will not be used for this
port and the corresponding entries for this port
will also be removed from portSecurityExtTable."
DEFVAL { 1 }
::= { portSecurityEntry 7 }
portSecurityAgingTime OBJECT-TYPE
SYNTAX INTEGER(0|10..1440)
UNITS "minutes"
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The interval in which the port is secured. After
the expiration of the time, the corresponding
portSecuritySecureSrcAddr or
portSecurityExtSecureSrcAddr will be removed from
the secure address list. If the value of this
object is 0, the aging mechanism is disabled."
DEFVAL { 0 }
::= {portSecurityEntry 8}
portSecurityShutdownTimeOut OBJECT-TYPE
SYNTAX INTEGER(0|10..1440)
UNITS "minutes"
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The interval in which the port is shutdown due to
the violation of security. After the expiration
of the time all the security configuration of this
port is re-installed and the port is enabled. If
the value of this object is 0, the port is shut
down permanently."
DEFVAL { 0 }
::= {portSecurityEntry 9}
portSecurityViolationPolicy OBJECT-TYPE
SYNTAX INTEGER { restrict(1), shutdown(2)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "If the value of this object is
restrict(1) - the port drops all packets with
insecured addresses.
shutdown(2) - the port is forced to shut down
if there is a violation of
security."
DEFVAL { shutdown }
::= {portSecurityEntry 10}
-- the port security extension table. This table will be used if
-- the portSecurityMaxSrcAddr for any port is set to value that is
-- greater than 1.
portSecurityExtTable OBJECT-TYPE
SYNTAX SEQUENCE OF PortSecurityExtEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A list of port security entries. The number of
entries is determined by the number of ports in
the system which support the Security feature and
the number of MAC addresses learned/configured to
be secured per port."
::= { securityGrp 2 }
portSecurityExtEntry OBJECT-TYPE
SYNTAX PortSecurityExtEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Entry containing security information for a
particular port and a particular MAC address. The
entry can be configured by the user and can be
added by the agent when the device learns a new
secured MAC address."
INDEX { portSecurityExtModuleIndex,
portSecurityExtPortIndex,
portSecurityExtSecureSrcAddr }
::= { portSecurityExtTable 1 }
PortSecurityExtEntry ::=
SEQUENCE {
portSecurityExtModuleIndex
INTEGER,
portSecurityExtPortIndex
INTEGER,
portSecurityExtSecureSrcAddr
OCTET STRING,
portSecurityExtControlStatus
INTEGER
}
portSecurityExtModuleIndex OBJECT-TYPE
SYNTAX INTEGER (1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "An index value that uniquely identifies the
module where this port is located
(see portModuleIndex)."
::= { portSecurityExtEntry 1 }
portSecurityExtPortIndex OBJECT-TYPE
SYNTAX INTEGER (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "An index value that uniquely identifies this port
within a module (see portIndex)."
::= { portSecurityExtEntry 2 }
portSecurityExtSecureSrcAddr OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (6))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "An index value that uniquely identifies the MAC
address, which is to be secured."
::= { portSecurityExtEntry 3}
portSecurityExtControlStatus OBJECT-TYPE
SYNTAX INTEGER { valid(1), invalid(2)}
MAX-ACCESS read-create
STATUS current
DESCRIPTION "This object used to add or remove a secured
MAC address of the corresponding port in
the row. If setting this object to valid(1), the
portSecurityExtSecureSrcAddr is made to be secured
for the port. If setting this object to
invalid(2), the portSecurityExtSecureSrcAddr is
no longer to be secured for the current port."
::= {portSecurityExtEntry 4}
-- the token ring group
-- Implementation of the token ring group is current for all Cisco
-- Workgroup Stack products which implement token ring functions
-- (wsx5030 and wsx5031).
-- Token Ring Port Configuration Table
tokenRingPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF TokenRingPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Table containing token ring configuration
information."
::= { tokenRingGrp 1 }
tokenRingPortEntry OBJECT-TYPE
SYNTAX TokenRingPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Entry containing token ring configuration
information for a particular port."
INDEX { tokenRingModuleIndex, tokenRingPortIndex }
::= { tokenRingPortTable 1 }
TokenRingPortEntry ::=
SEQUENCE {
tokenRingModuleIndex
INTEGER,
tokenRingPortIndex
INTEGER,
tokenRingPortSetACbits
INTEGER,
tokenRingPortMode
INTEGER,
tokenRingPortEarlyTokenRel
INTEGER,
tokenRingPortPriorityThresh
INTEGER,
tokenRingPortPriorityMinXmit
INTEGER,
tokenRingPortCfgLossThresh
INTEGER,
tokenRingPortCfgLossInterval
INTEGER
}
tokenRingModuleIndex OBJECT-TYPE
SYNTAX INTEGER (1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "An index value that uniquely identifies the
module where this port is located
(see portModuleIndex)."
::= { tokenRingPortEntry 1 }
tokenRingPortIndex OBJECT-TYPE
SYNTAX INTEGER (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "An index value that uniquely identifies this port
within a module (see portIndex)."
::= { tokenRingPortEntry 2 }
tokenRingPortSetACbits OBJECT-TYPE
SYNTAX INTEGER { enabled(1), disabled(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Specifies if the AC bits shall be set
unconditionally when a port forwards certain LLC
frames."
DEFVAL { disabled }
::= { tokenRingPortEntry 3 }
tokenRingPortMode OBJECT-TYPE
SYNTAX INTEGER { auto(1),
fdxCport(2),
fdxStation(3),
hdxCport(4),
hdxStation(5),
riro(7) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Specifies the port's mode of operation.
auto: Automatically detect the port mode
upon insertion.
fdxCport: Transmit Immediate (full-duplex)
Concentrator Port
fdxStation: Transmit Immediate (full-duplex)
Station emulation
hdxCport: Token Passing Protocol (half-duplex)
Concentrator Port
hdxStation: Token Passing Protocol (half-duplex)
Station emulation
riro: RingIn/RingOut mode. (wsx5031 only)"
DEFVAL { auto }
::= { tokenRingPortEntry 4 }
-- tokenRingPortEntry 5 to 8 are not used
tokenRingPortEarlyTokenRel OBJECT-TYPE
SYNTAX INTEGER { enabled(1), disabled(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "This object provides the ability to enable or
disable early token release for a particular port.
Early token release only applies to ports
operating at 16 Mbps. If ifSpeed reflects 4 Mbps
for a particular port, then the corresponding
instance of this object will have a value of
disabled(2) regardless of attempts to set the
object to enabled(1).
Whenever a port is opened with a ring speed of
16 Mbps, by default, early token release will be
enabled."
::= { tokenRingPortEntry 9 }
tokenRingPortPriorityThresh OBJECT-TYPE
SYNTAX INTEGER (0..7)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The highest token ring frame priority that shall
go to the low-priority transmit queue."
DEFVAL { 3 }
::= { tokenRingPortEntry 10 }
tokenRingPortPriorityMinXmit OBJECT-TYPE
SYNTAX INTEGER (0..6)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The minimum token priority that will be used for
transmit."
DEFVAL { 4 }
::= { tokenRingPortEntry 11 }
tokenRingPortCfgLossThresh OBJECT-TYPE
SYNTAX INTEGER (1..100)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Number of configuration loss events during the
sample interval which, if exceeded, should cause
the port to be disabled. If the port is disabled
by this function the port must be administratively
re-enabled."
DEFVAL { 8 }
::= { tokenRingPortEntry 12 }
tokenRingPortCfgLossInterval OBJECT-TYPE
SYNTAX INTEGER (1..9999)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The sampling interval, in minutes, for which the
port monitors to see if the configuration loss
threshold has been exceeded."
DEFVAL { 10 }
::= { tokenRingPortEntry 13 }
-- DRiP related objects.
tokenRingDripDistCrfMode OBJECT-TYPE
SYNTAX INTEGER { enabled(1), disabled(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "This object reflects whether TR-CRFs can be
distributed across ISL topologies. Setting
this object to enabled(1) allows TR-CRFs to be
distributed. Setting this object to disabled(2)
prevents TR-CRFs from being distributed across
ISL topologies. When this object is set to
disabled(2), the system will disable ports
involved in the distributed TR-CRF."
DEFVAL { disabled }
::= { tokenRingGrp 2 }
tokenRingDripAreReductionMode OBJECT-TYPE
SYNTAX INTEGER { enabled(1), disabled(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "This object reflects whether or not All
Routes Explorer (ARE) reduction capabilities are
enabled or disabled on this system. Setting
this object to enabled(1) will permit DRiP to
participate in the configuration of Token Ring
ports ARE reduction capabilities on the system.
Setting this object to disabled(2) will prevent
DRiP from participating in the configuration
of Token Ring port ARE reduction capabilities."
DEFVAL { enabled }
::= { tokenRingGrp 3 }
tokenRingDripLocalNodeID OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(6))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The unique system identifier that will be sent
in all advertisements generated by this system.
It uniquely identifies this system from other
DRiP capable systems."
::= { tokenRingGrp 4 }
tokenRingDripLastRevision OBJECT-TYPE
SYNTAX INTEGER (0..9999999)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The revision number transmitted in the most
recent advertisement. That advertisement may
or may not have contained changed data."
::= { tokenRingGrp 5 }
tokenRingDripLastChangedRevision OBJECT-TYPE
SYNTAX INTEGER (0..9999999)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The revision number transmitted in the most
recent advertisement containing changed data."
::= { tokenRingGrp 6 }
tokenRingDripAdvertsReceived OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The number of DRiP advertisements received
by this system."
::= { tokenRingGrp 7 }
tokenRingDripAdvertsTransmitted OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The number of DRiP advertisements transmitted
by this system."
::= { tokenRingGrp 8 }
tokenRingDripAdvertsProcessed OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The number of DRiP advertisements processed
by this system."
::= { tokenRingGrp 9 }
tokenRingDripInputQueueDrops OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The number of DRiP advertisements dropped
from this system's input queue."
::= { tokenRingGrp 10 }
tokenRingDripOutputQueueDrops OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The number of DRiP advertisements dropped
from this system's output queue."
::= { tokenRingGrp 11 }
tokenRingDripLocalVlanStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF TokenRingDripLocalVlanStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table containing DRiP VLAN status information
local to this system. The existence of an
entry indicates that at least one local port
is assigned to the associated TR-CRF VLAN."
::= { tokenRingGrp 12 }
tokenRingDripLocalVlanStatusEntry OBJECT-TYPE
SYNTAX TokenRingDripLocalVlanStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Entry containing DRiP related information for
a particular TR-CRF VLAN."
INDEX { tokenRingDripVlan }
::= { tokenRingDripLocalVlanStatusTable 1 }
TokenRingDripLocalVlanStatusEntry ::=
SEQUENCE {
tokenRingDripVlan
VlanIndex,
tokenRingDripLocalPortStatus
INTEGER,
tokenRingDripRemotePortStatus
INTEGER,
tokenRingDripRemotePortConfigured
INTEGER,
tokenRingDripDistributedCrf
INTEGER,
tokenRingDripBackupCrf
INTEGER,
tokenRingDripOwnerNodeID
OCTET STRING
}
tokenRingDripVlan OBJECT-TYPE
SYNTAX VlanIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A TR-CRF VLAN ID."
::= { tokenRingDripLocalVlanStatusEntry 1 }
tokenRingDripLocalPortStatus OBJECT-TYPE
SYNTAX INTEGER { active(1), inactive(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object reflects DRiP's status regarding
the overall set of local ports assigned to
the TR-CRF VLAN associated with this entry.
A value of active(1) indicates that at least
one local port is inserted/connected (i.e.,
active on the Token Ring). A value of inactive(2)
indicates that none of the local ports are
inserted/connected. All local ports are either
disabled or are simply not connected."
::= { tokenRingDripLocalVlanStatusEntry 2 }
tokenRingDripRemotePortStatus OBJECT-TYPE
SYNTAX INTEGER { active(1), inactive(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object reflects DRiP's status regarding
any ports on remote systems. A value of
active(1) indicates that at least one remote
port is inserted/connected (i.e., active on
the Token Ring). A value of inactive(2) indicates
that none of the remote ports are
inserted/connected. All remote ports are either
disabled or are simply not connected."
::= { tokenRingDripLocalVlanStatusEntry 3 }
tokenRingDripRemotePortConfigured OBJECT-TYPE
SYNTAX INTEGER { true(1), false(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object reflects whether or not DRiP has
detected remote ports assigned to the TR-CRF
VLAN associated with this entry. A value of
true(1) indicates there is at least one port
on a remote system assigned to this TR-CRF VLAN.
A value of false(2) indicates no remote ports
are assigned to this TR-CRF VLAN."
::= { tokenRingDripLocalVlanStatusEntry 4 }
tokenRingDripDistributedCrf OBJECT-TYPE
SYNTAX INTEGER { true(1), false(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object reflects whether DRiP considers the
TR-CRF VLAN associated with this entry to be
distributed across systems. A value of true(1)
indicates the TR-CRF is distributed. A value
of false(2) indicates the TR-CRF is not
distributed."
::= { tokenRingDripLocalVlanStatusEntry 5 }
tokenRingDripBackupCrf OBJECT-TYPE
SYNTAX INTEGER { true(1), false(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object reflects whether or not the TR-CRF
VLAN associated with this entry is configured
as a backup TR-CRF. A value of true(1) indicates
the TR-CRF is a configured as a backup. A value
of false(2) indicates the TR-CRF is not configured
as a backup."
::= { tokenRingDripLocalVlanStatusEntry 6 }
tokenRingDripOwnerNodeID OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(6))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The unique identifier of the system that has
advertised that it has local ports assigned to the
TR-CRF VLAN associated with this entry."
::= { tokenRingDripLocalVlanStatusEntry 7 }
-- Token Ring Port Soft Error Monitoring Configuration Table
tokenRingPortSoftErrTable OBJECT-TYPE
SYNTAX SEQUENCE OF TokenRingPortSoftErrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Table containing token ring soft error monitoring
configuration information."
::= { tokenRingGrp 14 }
tokenRingPortSoftErrEntry OBJECT-TYPE
SYNTAX TokenRingPortSoftErrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Entry containing token ring soft error monitoring
configuration information for a particular port."
AUGMENTS { tokenRingPortEntry }
::= { tokenRingPortSoftErrTable 1 }
TokenRingPortSoftErrEntry ::= SEQUENCE {
tokenRingPortSoftErrThresh
INTEGER,
tokenRingPortSoftErrReportInterval
INTEGER,
tokenRingPortSoftErrResetCounters
INTEGER,
tokenRingPortSoftErrLastCounterReset
TimeTicks,
tokenRingPortSoftErrEnable
INTEGER
}
tokenRingPortSoftErrThresh OBJECT-TYPE
SYNTAX INTEGER ( 1..255 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The number of soft errors reported from a station
connected to this port which, if exceeded, should
cause a soft error exceeded trap to be issued.
The error counters being monitored and compared to
this threshold value are all of the error counters
in the ringStationTable (see RFC 1513)."
DEFVAL { 100 }
::= { tokenRingPortSoftErrEntry 1 }
tokenRingPortSoftErrReportInterval OBJECT-TYPE
SYNTAX INTEGER ( 0..65535 )
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The sampling period, in seconds, in which each
station connected to this port will be monitored
for excessive soft error reports. If a station
reports more than tokenRingPortSoftErrThreshold
errors within the sampling period a trap will be
issued to the management station(s). Setting a
value of 0 will cause no traps to be sent for
this port."
DEFVAL { 60 }
::= { tokenRingPortSoftErrEntry 2 }
tokenRingPortSoftErrResetCounters OBJECT-TYPE
SYNTAX INTEGER { noop(1), reset(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "When this object is set to reset(2), all Soft
Error Monitoring related counters on this port
will be set to 0."
::= { tokenRingPortSoftErrEntry 3 }
tokenRingPortSoftErrLastCounterReset OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The time (in hundredths of a second) since Soft
Error Monitoring counters for this port were last
cleared."
::= { tokenRingPortSoftErrEntry 4 }
tokenRingPortSoftErrEnable OBJECT-TYPE
SYNTAX INTEGER { enabled(1), disabled(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Indicates whether the Token Ring Soft Error
Monitoring feature is enabled on this port or not.
The detailed soft error statistics are provided
by Token Ring RMON SNMP objects. Thus, if RMON
(sysEnableRmon) is disabled(2) then the soft error
statistics will only be available from the CLI."
DEFVAL { disabled }
::= { tokenRingPortSoftErrEntry 5 }
-- the multicast group
-- Implementation of the multicast group is optional, but within the
-- group all the elements are current. If multicast features are
-- supported, the entire group should be implemented.
-- the multicast router table
mcastRouterTable OBJECT-TYPE
SYNTAX SEQUENCE OF McastRouterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A list of multicast router port entries. The
number of entries is determined by the number of
ports in the system."
::= { multicastGrp 1 }
mcastRouterEntry OBJECT-TYPE
SYNTAX McastRouterEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Entry containing multicast router information for
a particular port."
INDEX { mcastRouterModuleIndex, mcastRouterPortIndex }
::= { mcastRouterTable 1 }
McastRouterEntry ::=
SEQUENCE {
mcastRouterModuleIndex
INTEGER,
mcastRouterPortIndex
INTEGER,
mcastRouterAdminStatus
INTEGER,
mcastRouterOperStatus
INTEGER
}
mcastRouterModuleIndex OBJECT-TYPE
SYNTAX INTEGER (1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "An index value that uniquely identifies the
module where this port is located
(see portModuleIndex)."
::= { mcastRouterEntry 1 }
mcastRouterPortIndex OBJECT-TYPE
SYNTAX INTEGER (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "An index value that uniquely identifies this port
within a module (see portIndex)."
::= { mcastRouterEntry 2 }
mcastRouterAdminStatus OBJECT-TYPE
SYNTAX INTEGER { routerPresent(1),
dynamic(3) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "And indication of whether the presence of an IP
multicast router on this port is to be determined
statically or dynamically. The value
routerPresent(1) indicates that the presence of a
router is statically configured to be present.
The value dynamic(3) indicates the presence is to
be learned dynamically."
DEFVAL { dynamic }
::= { mcastRouterEntry 3 }
mcastRouterOperStatus OBJECT-TYPE
SYNTAX INTEGER { routerPresent(1), noRouter(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION "An indication of whether an IP multicast router
is present on this port."
::= { mcastRouterEntry 4 }
mcastEnableCgmp OBJECT-TYPE
SYNTAX INTEGER { enabled(1), disabled(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Indicates whether Cisco Group Management Protocol
is enabled on the device or not. When CGMP is
enabled in conjunction with Cisco routers running
CGMP, only the required ports will participate in
IP multicast groups."
DEFVAL { disabled }
::= { multicastGrp 2 }
mcastEnableIgmp OBJECT-TYPE
SYNTAX INTEGER { enabled(1), disabled(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Indicates whether Internet Group Management
Protocol is enabled on the device or not. When
IGMP is enabled in conjunction with Cisco routers
running CGMP, only the required ports will
participate in IP multicast groups."
DEFVAL { disabled }
::= { multicastGrp 3 }
mcastEnableRgmp OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Indicates whether Router Group Management
Protocol is enabled on the device or not. When
RGMP is enabled in conjunction with Cisco routers
running RGMP, multicast data traffic is forwarded
only to those multicast routers that are
interested to receive that data traffic. IGMP
snooping feature must be enabled on the system
to make RGMP feature operational."
DEFVAL { disabled }
::= { multicastGrp 4 }
-- the DNS group
-- Implementation of the DNS group is optional, but within the group
-- all the elements are current. If DNS features are supported,
-- the entire group should be implemented.
dnsEnable OBJECT-TYPE
SYNTAX INTEGER { enabled(1), disabled(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Indicates if the DNS feature is enabled or
disabled."
DEFVAL { disabled }
::= { dnsGrp 1}
dnsServerTable OBJECT-TYPE
SYNTAX SEQUENCE OF DnsServerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table lists a maximum of 3 DNS servers."
::= { dnsGrp 2 }
dnsServerEntry OBJECT-TYPE
SYNTAX DnsServerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A DNS server table entry."
INDEX { dnsServerAddr }
::= { dnsServerTable 1 }
DnsServerEntry ::=
SEQUENCE {
dnsServerAddr
IpAddress,
dnsServerType
INTEGER
}
dnsServerAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The IP address of a DNS server."
::= { dnsServerEntry 1 }
dnsServerType OBJECT-TYPE
SYNTAX INTEGER {
invalid(1), -- remove this entry
primary(2), -- the primary entry
other(3) -- a lower priority entry
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION "To add a new entry to the dnsServerTable, set
this object to primary(2) or other(3) for an IP
address which is not already in the table. The
primary entry will be used first, if it is
reachable. Otherwise, one of the other entries
will be used. Setting one entry to primary(2)
causes any previous primary entry to change to
other(3). To remove an entry from the table, set
this object to invalid(1)."
::= { dnsServerEntry 2 }
dnsDomainName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..127))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "DNS domain name."
REFERENCE "RFC1035, section 2.3.1 Preferred name syntax."
::= { dnsGrp 3 }
-- the syslog (System Log Information) group
-- Implementation of the syslog group is optional, but within the group
-- all the elements are current. If the syslog feature is supported,
-- the entire group should be implemented.
syslogServerTable OBJECT-TYPE
SYNTAX SEQUENCE OF SyslogServerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table lists a maximum of 3 system log
servers."
::= { syslogGrp 1 }
syslogServerEntry OBJECT-TYPE
SYNTAX SyslogServerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A system log server table entry."
INDEX { syslogServerAddr }
::= { syslogServerTable 1 }
SyslogServerEntry ::=
SEQUENCE {
syslogServerAddr
IpAddress,
syslogServerType
INTEGER
}
syslogServerAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The IP address of a system log Server."
::= { syslogServerEntry 1 }
syslogServerType OBJECT-TYPE
SYNTAX INTEGER {
valid(1), -- add this entry
invalid(2) -- remove this entry
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION "To add/remove a new entry to the
syslogServerTable, setting to invalid(2) removes
the corresponding entry from the
syslogServerTable. To add a new entry into
syslogServerTable, set this object to valid(1)
for an IP address which is not already in the
table."
::= { syslogServerEntry 2 }
syslogConsoleEnable OBJECT-TYPE
SYNTAX INTEGER { enabled(1), disabled(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Indicate whether the system log messages should
be sent to console."
DEFVAL { disabled }
::= { syslogGrp 2 }
syslogHostEnable OBJECT-TYPE
SYNTAX INTEGER { enabled(1), disabled(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Indicate whether the system log messages should
be sent to syslog servers."
DEFVAL { disabled }
::= { syslogGrp 3 }
syslogMessageControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF SyslogMessageControlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table contains the information about what
system log messages should be sent to syslog host,
console, login session, and/or logged into the
internal buffer."
::= { syslogGrp 4 }
syslogMessageControlEntry OBJECT-TYPE
SYNTAX SyslogMessageControlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A system log message control table entry."
INDEX { syslogMessageFacility }
::= { syslogMessageControlTable 1 }
SyslogMessageControlEntry ::=
SEQUENCE {
syslogMessageFacility
INTEGER,
syslogMessageSeverity
INTEGER
}
syslogMessageFacility OBJECT-TYPE
SYNTAX INTEGER {
cdp(1),
mcast(2),
dtp(3),
dvlan(4),
earl(5),
fddi(6),
ip(7),
pruning(8),
snmp(9),
spantree(10),
system(11),
tac(12),
tcp(13),
telnet(14),
tftp(15),
vtp(16),
vmps(17),
kernel(18),
filesys(19),
drip(20),
pagp(21),
mgmt(22),
mls(23),
protfilt(24),
security(25),
radius(26),
udld(27),
gvrp(28),
cops(29),
qos(30),
acl(31),
rsvp(32),
ld(33),
privatevlan(34),
ethc(35),
gl2pt(36),
callhome(37),
dhcpsnooping(38),
diags(40),
eou(42),
backup(43),
eoam(44),
webauth(45)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "System log message facility."
::= { syslogMessageControlEntry 1 }
syslogMessageSeverity OBJECT-TYPE
SYNTAX INTEGER {
emergencies(1),
alerts(2),
critical(3),
errors(4),
warnings(5),
notification(6),
informational(7),
debugging(8)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION "System log message severity."
::= { syslogMessageControlEntry 2 }
syslogTimeStampOption OBJECT-TYPE
SYNTAX INTEGER{
enabled(1),
disabled(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Indicates whether syslog Time Stamp Option is
enabled or not. If it is set to enabled(1), the
Time Stamp will be in the beginning of each
syslog message."
::= { syslogGrp 5 }
syslogTelnetEnable OBJECT-TYPE
SYNTAX INTEGER { enabled(1), disabled(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Indicate whether the system log messages should
be sent to telnet sessions."
DEFVAL { enabled }
::= { syslogGrp 6 }
-- the NTP (Network Time Protocol) group
-- Implementation of the NTP group is optional, but within the group
-- all the elements are current. If the NTP feature is supported,
-- the entire group should be implemented.
-- the NTP table
ntpBcastClient OBJECT-TYPE
SYNTAX INTEGER { enabled(1), disabled(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Entry which tells if Cat5000 should act as a
Broadcast client or not."
DEFVAL { disabled }
::= { ntpGrp 1 }
ntpBcastDelay OBJECT-TYPE
SYNTAX INTEGER (1..999999)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Estimated Round trip time (in micro seconds) for
NTP broadcasts. The range is from 1 to 999999."
DEFVAL { 3000 }
::= { ntpGrp 2 }
ntpClient OBJECT-TYPE
SYNTAX INTEGER { enabled(1), disabled(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Entry which tells if the device can act as a NTP
client (in a client-server configuration type)."
DEFVAL { disabled }
::= { ntpGrp 3 }
ntpServerTable OBJECT-TYPE
SYNTAX SEQUENCE OF NtpServerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A list of NTP Server entries. This table lists a
maximum of 10 Entries."
::= { ntpGrp 4 }
ntpServerEntry OBJECT-TYPE
SYNTAX NtpServerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Entry containing NTP information for a particular
entry."
INDEX { ntpServerAddress }
::= { ntpServerTable 1 }
NtpServerEntry ::= SEQUENCE {
ntpServerAddress
IpAddress,
ntpServerType
INTEGER,
ntpServerPublicKey
Unsigned32
}
ntpServerAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Entry containing NTP Server's IP address."
::= { ntpServerEntry 1 }
ntpServerType OBJECT-TYPE
SYNTAX INTEGER{
valid(1), -- add this entry
invalid(2) -- remove this entry
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "To add or remove an entry to ntpServerTable.
Setting to 1 adds the entry and setting to 2
clears the entry."
::= { ntpServerEntry 2 }
ntpServerPublicKey OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The key to be used when communicating with this
server.
A key with a value of zero indicates an invalid
ntpServerPublicKey. When the authentication
feature is enabled the system will not sync with
this server when ntpAuthenticationPublicKey
doesn't match with NTP Packet's public key.
or
If the ntpAuthenticationTrustedMode is trusted but
encrypted message of ntpAuthenticationSecretKey
with NTP packet's data doesn't match with NTP
packet's crypto checksum in the message
authentication mode (MAC).
or
If the ntpAuthenticationTrustedMode is untrusted.
In client mode NMP will not send request NTP
Packet to the server when ntpServerPublicKey
doesn't match with any of the
ntpAuthenticationPublicKey in
ntpAuthenticationTable.
or
If the ntpAuthenticationTrustedMode is untrusted."
::= { ntpServerEntry 3 }
ntpSummertimeStatus OBJECT-TYPE
SYNTAX INTEGER { enabled(1), disabled(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Enabling or Disabling will set the clock ahead or
behind 1 hour respectively.(daylight savings time
in USA). This command gets active only in Summer
time."
DEFVAL { disabled }
::= { ntpGrp 5 }
ntpSummerTimezoneName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Summertime time zone name for display purposes."
::= { ntpGrp 6 }
ntpTimezoneName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Time zone name for display purposes."
::= { ntpGrp 7 }
ntpTimezoneOffsetHour OBJECT-TYPE
SYNTAX INTEGER (-12..12)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Time offset (Hour) from Greenwich Mean Time."
::= { ntpGrp 8 }
ntpTimezoneOffsetMinute OBJECT-TYPE
SYNTAX INTEGER (0..59)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Time offset (Minutes) from Greenwich Mean Time."
::= { ntpGrp 9 }
ntpAuthenticationEnable OBJECT-TYPE
SYNTAX INTEGER { enabled(1), disabled(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Specifies if authentication feature is enabled or
disabled in the system."
DEFVAL { disabled }
::= { ntpGrp 10 }
ntpAuthenticationTable OBJECT-TYPE
SYNTAX SEQUENCE OF NtpAuthenticationEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A list of NTP Authentication Key entries.
This table lists a maximum of 10 Entries"
::= { ntpGrp 11 }
ntpAuthenticationEntry OBJECT-TYPE
SYNTAX NtpAuthenticationEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in the ntpAuthenticationTable,
containing values of an NTP authentication key
pair."
INDEX { ntpAuthenticationPublicKey }
::= { ntpAuthenticationTable 1 }
NtpAuthenticationEntry ::=
SEQUENCE {
ntpAuthenticationPublicKey
Unsigned32,
ntpAuthenticationSecretKey
DisplayString,
ntpAuthenticationTrustedMode
INTEGER,
ntpAuthenticationType
INTEGER
}
ntpAuthenticationPublicKey OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A unique value to identify the authentication
key. When the authentication feature is enabled
and the ntpAuthenticationPublicKey matches with
the NTP packet's public key then this entry is
used."
::= { ntpAuthenticationEntry 1}
ntpAuthenticationSecretKey OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..32))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "An arbitrary string known as the secret key used
for encrypting of the NTP packet. This key is
useful when the ntpAuthenticationTrustedMode is
set to trusted(1).
This key has to be specified when this
ntpAuthenticationEntry is created. When reading
this object, it will return empty string."
::= { ntpAuthenticationEntry 2}
ntpAuthenticationTrustedMode OBJECT-TYPE
SYNTAX INTEGER {
trusted(1),
untrusted(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "A flag indicates whether the
ntpAuthenticationSecretKey is trusted or
untrusted. Setting a ntpAuthenticationSecretKey
to trusted(1) allows authentication on NTP
packets containing this key, and setting a
ntpAuthenticationSecretKey to untrusted(2) drops
all NTP packets containing this key."
::= { ntpAuthenticationEntry 3}
ntpAuthenticationType OBJECT-TYPE
SYNTAX INTEGER {
valid(1), -- add this entry
invalid(2) -- remove this entry
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "To add or remove an entry to
ntpAuthenticationTable. Setting to 1 adds the
entry and setting to 2 clears the entry."
::= { ntpAuthenticationEntry 4}
-- the TACACS (Terminal Access Controller Access Control System) group
-- Implementation of the TACACS group is optional, but within the group
-- all the elements are current. If the TACACS+ feature is
-- implemented, the entire group should be implemented.
tacacsLoginAuthentication OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2),
enabledForTelnetOnly(3),
enabledForConsoleOnly(4)
}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION "Indicates whether the login authentication using
the TACACS+ feature is enabled or disabled for
console sessions and/or telnet sessions.
Setting this object to enabled(1), the login
authentication using the TACACS+ feature is
enabled for both telnet and console sessions.
Setting this object to disabled(2), the login
authentication using the TACACS+ feature is
disabled for both telnet and console sessions.
Setting this object to enabledForTelnetOnly(3),
the login authentication using the TACACS+
feature is enabled only for telnet sessions, but
disabled for console sessions.
Setting this object to enabledForConsoleOnly(4),
the login authentication using the TACACS+
feature is enabled only for console sessions,
but disabled for telnet sessions.
This object is deprecated and replaced by
cacPriorityTable in CISCO-AAA-CLIENT-MIB."
DEFVAL { disabled }
::= { tacacsGrp 1 }
tacacsEnableAuthentication OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2),
enabledForTelnetOnly(3),
enabledForConsoleOnly(4)
}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION "Indicates whether the enable authentication using
the TACACS+ feature is enabled or disabled for
console sessions and/or telnet sessions based on
the value.
Setting this object to enabled(1), the enable
authentication using the TACACS+ feature is
enabled for both telnet and console sessions.
Setting this object to disabled(2), the enable
authentication using the TACACS+ feature is
disabled for both telnet and console sessions.
Setting this object to enabledForTelnetOnly(3),
the enable authentication using the TACACS+
feature is enabled only for telnet sessions, but
disabled for console sessions.
Setting this object to enabledForConsoleOnly(4),
the enable authentication using the TACACS+
feature is enabled only for console sessions,
but disabled for telnet sessions.
This object is deprecated and replaced by
cacPriorityTable in CISCO-AAA-CLIENT-MIB."
DEFVAL { disabled }
::= { tacacsGrp 2 }
tacacsLocalLoginAuthentication OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2),
enabledForTelnetOnly(3),
enabledForConsoleOnly(4)
}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION "Indicates whether the login authentication using
local password is enabled or disabled for Console
session and/or Telnet session based on the value.
Setting this object to enabled(1),the login
authentication using local password is enabled for
both telnet and console sessions.
Setting this object to disabled(2), the login
authentication using local password is disabled
for both telnet and console sessions.
Setting this object to enabledForTelnetOnly(3),
the login authentication using local password is
enabled only for telnet sessions, but disabled for
console session.
Setting this object to enabledForConsoleOnly(4),
the login authentication using local password is
enabled only for console session, but disabled for
telnet sessions.
This object is deprecated and replaced by
cacPriorityTable in CISCO-AAA-CLIENT-MIB."
DEFVAL { enabled }
::= { tacacsGrp 3 }
tacacsLocalEnableAuthentication OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2),
enabledForTelnetOnly(3),
enabledForConsoleOnly(4)
}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION "Indicates whether the enable authentication using
local password is enabled or disabled for Console
session and/or Telnet sessions.
Setting this object to enabled(1),the enable
authentication using local password is enabled for
both telnet and console sessions.
Setting this object to disabled(2), the enable
authentication using local password is disabled
for both telnet and console sessions.
Setting this object to enabledForTelnetOnly(3),
the enable authentication using local password is
enabled only for telnet sessions, but disabled for
console sessions.
Setting this object to enabledForConsoleOnly(4),
the enable authentication using local password is
enabled only for console sessions, but disabled
for telnet sessions.
This object is deprecated and replaced by
cacPriorityTable in CISCO-AAA-CLIENT-MIB."
DEFVAL { enabled }
::= { tacacsGrp 4 }
tacacsNumLoginAttempts OBJECT-TYPE
SYNTAX INTEGER (1..10)
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION "The number of login attempts allowed.
This object is deprecated and replaced by
cacMaxLoginAttempt in CISCO-AAA-CLIENT-MIB."
DEFVAL { 3 }
::= { tacacsGrp 5 }
tacacsDirectedRequest OBJECT-TYPE
SYNTAX INTEGER { enabled(1), disabled(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Indicates whether the directed-request feature of
TACACS+ is enabled or disabled."
DEFVAL { disabled }
::= { tacacsGrp 6 }
tacacsTimeout OBJECT-TYPE
SYNTAX INTEGER (1..255)
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION "The duration in seconds to wait for a response
from the TACACS+ server host.
This object is deprecated and replaced by
cacLockoutPeriodExt in CISCO-AAA-CLIENT-MIB."
DEFVAL { 5 }
::= { tacacsGrp 7 }
tacacsAuthKey OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..100))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The key used in encrypting the packets passed
between the TACACS+ server and the client. This
key must match the one configured on the server.
Note that this item is only accessible when using
the community string defined in sysCommunityRwa."
-- DEFVAL { NULL }
::= { tacacsGrp 8 }
tacacsServerTable OBJECT-TYPE
SYNTAX SEQUENCE OF TacacsServerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table lists a maximum of 3 TACACS+ servers."
::= { tacacsGrp 9 }
tacacsServerEntry OBJECT-TYPE
SYNTAX TacacsServerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A TACACS+ server table entry."
INDEX { tacacsServerAddr }
::= { tacacsServerTable 1 }
TacacsServerEntry ::=
SEQUENCE {
tacacsServerAddr
IpAddress,
tacacsServerType
INTEGER
}
tacacsServerAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The IP address of a TACACS+ Server."
::= { tacacsServerEntry 1 }
tacacsServerType OBJECT-TYPE
SYNTAX INTEGER {
invalid(1), -- remove this entry
primary(2), -- the primary entry
other(3) -- a lower priority entry
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION "To add a new entry to the tacacsServerTable, set
this object to primary(2) or other(3) for an IP
address which is not already in the table. The
primary entry will be used first, if it is
reachable. Otherwise, one of the other entries
will be used. Setting one entry to primary(2)
causes any previous primary entry to change to
other(3). To remove an entry from the table, set
this object to invalid(1)."
::= { tacacsServerEntry 2 }
-- the ip permit list group
-- Implementation of the ip permit list group is optional, but within
-- the group all the elements are current. If the ip permit list
-- feature is supported, the entire group should be implemented.
ipPermitEnable OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2),
enabledForTelnetOnly(3),
enabledForSnmpOnly(4)
}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION "This is deprecated and replaced by
ipPermitAccessTypeEnable.
Indicate whether the IP permit feature is enabled
or disabled for Telnet and/or SNMP.
Setting this object to enabled(1), the IP permit
feature is enabled for both telnet and SNMP.
Setting this object to disabled(2), the IP permit
feature is disabled for both telnet and SNMP.
Setting this object to enabledForTelnetOnly(3),
the IP permit feature is enabled for Telnet, but
disabled for the rest.
Setting this object to enabledForSnmpOnly(4), the
IP permit feature is enabled for SNMP, but
disabled for the rest."
DEFVAL { disabled }
::= { ipPermitListGrp 1 }
-- the ip permit list table
ipPermitListTable OBJECT-TYPE
SYNTAX SEQUENCE OF IpPermitListEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table lists a maximum of 100 IP Addresses
with net masks of IP permit hosts. If
ipPermitEnable is set to enabled(1), the system
will only accept inbound accesses which come from
the configured hosts with their permit access
types in this table."
::= { ipPermitListGrp 2 }
ipPermitListEntry OBJECT-TYPE
SYNTAX IpPermitListEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A IP permit list table entry."
INDEX { ipPermitAddress, ipPermitMask }
::= { ipPermitListTable 1 }
IpPermitListEntry ::=
SEQUENCE {
ipPermitAddress
IpAddress,
ipPermitMask
IpAddress,
ipPermitType
INTEGER,
ipPermitAccessType
BITS
}
ipPermitAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The IP address of a IP permit host."
::= { ipPermitListEntry 1 }
ipPermitMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The IP net mask of a IP permit host."
::= { ipPermitListEntry 2 }
ipPermitType OBJECT-TYPE
SYNTAX INTEGER {
valid(1), --add this entry
invalid(2) --remove this entry
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Setting this object to invalid(2), removes the
corresponding entry from the ipPermitListTable. To
add a new entry into ipPermitListTable, set this
object to valid(1), for an IP address and IP net
mask which are not already in the table."
::= { ipPermitListEntry 3 }
ipPermitAccessType OBJECT-TYPE
SYNTAX BITS {
telnet(0),
snmp(1),
ssh(2),
http(3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The IP access type of a IP permit host.
At least one access type has to be set."
DEFVAL {{ telnet, snmp, ssh, http }}
::= { ipPermitListEntry 4 }
ipPermitDeniedListTable OBJECT-TYPE
SYNTAX SEQUENCE OF IpPermitDeniedListEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table lists up to 10 the most recently
denied IP addresses with the access type."
::= { ipPermitListGrp 3 }
ipPermitDeniedListEntry OBJECT-TYPE
SYNTAX IpPermitDeniedListEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A IP permit denied list table entry."
INDEX {ipPermitDeniedAddress}
::= { ipPermitDeniedListTable 1}
IpPermitDeniedListEntry ::=
SEQUENCE {
ipPermitDeniedAddress
IpAddress,
ipPermitDeniedAccess
INTEGER,
ipPermitDeniedTime
TimeTicks
}
ipPermitDeniedAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The IP address of a IP permit denied access."
::= { ipPermitDeniedListEntry 1 }
ipPermitDeniedAccess OBJECT-TYPE
SYNTAX INTEGER { telnet(1), snmp(2), ssh(3), http(4) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The denied access type."
::= { ipPermitDeniedListEntry 2 }
ipPermitDeniedTime OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The time (in hundredths of a second) since the IP
permit denied access happens."
::= { ipPermitDeniedListEntry 3 }
ipPermitAccessTypeEnable OBJECT-TYPE
SYNTAX BITS {
telnet(0),
snmp(1),
ssh(2),
http(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "This is to replace ipPermitEnable.
Indicates whether the IP permit feature is
enabled or disabled for Telnet, SNMP, ssh and
http. If a bit is set the coresponding feature is
enabled. If a bit is not set the coresponding
feature is disabled."
DEFVAL { { } }
::= { ipPermitListGrp 4 }
-- the portChannel group
-- the port channel table
portChannelTable OBJECT-TYPE
SYNTAX SEQUENCE OF PortChannelEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION "A list of port channel entries. The number of
entries is determined by the number of ports in
the system which support the Ethernet Channelling
feature.
This table is deprecated and replaced by
pagpEtherChannelTable in CISCO-PAGP-MIB and
dot3adAggTable in IEEE8023-LAG-MIB."
::= { portChannelGrp 1 }
portChannelEntry OBJECT-TYPE
SYNTAX PortChannelEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION "Entry containing information for a particular
port on a module."
INDEX { portChannelModuleIndex, portChannelPortIndex }
::= { portChannelTable 1 }
PortChannelEntry ::=
SEQUENCE {
portChannelModuleIndex
INTEGER,
portChannelPortIndex
INTEGER,
portChannelPorts
OCTET STRING,
portChannelAdminStatus
INTEGER,
portChannelOperStatus
INTEGER,
portChannelNeighbourDeviceId
OCTET STRING,
portChannelNeighbourPortId
INTEGER,
portChannelProtInPackets
Counter32,
portChannelProtOutPackets
Counter32,
portChannelIfIndex
INTEGER
}
portChannelModuleIndex OBJECT-TYPE
SYNTAX INTEGER (1..16)
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "An index value that uniquely identifies the
module where this port is located."
::= { portChannelEntry 1 }
portChannelPortIndex OBJECT-TYPE
SYNTAX INTEGER (1..255)
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "An index value that uniquely identifies this port
within a module (see portIndex)."
::= { portChannelEntry 2 }
portChannelPorts OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..8))
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION "The set of ports on a module channelling
together. Each Octet within the value of this
object specifies a set of eight ports, with the
first octet specifying ports 1 through 8, the
second octet specifying ports 9 through 16, etc.
Within each octet, the most significant bit
represents the lowest numbered port, and the
least significant bit rep resents the highest
numbered port. Thus, each port is represented by
a single bit within the value of this object. If
that bit has a value of `1' then that port is
included in the set of channel ports. The default
value of this object is a string which only has a
value of `1' on its own port."
::= { portChannelEntry 3 }
portChannelAdminStatus OBJECT-TYPE
SYNTAX INTEGER { on(1),
off(2),
desirable(3),
auto(4),
desirableSilent(5),
autoSilent(6) }
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION "Indicates the administrative status set on the
channel ports. If the status is set to on(1), the
channelling is enabled. If the status is set to
off(2), the channelling is disabled. If the status
is set to desirable(3), the port initiates a pagp
negotiation request to become a channel and will
become a channel if the far end agrees. If the
status is set to auto(4), the port does not
initiate a request to become a channel but will do
so if it receives a request to become a channel
from the far end. If the status is set to
desirableSilent(5), the port initiates a pagp
negotiation request to become a channel and will
become a channel if the far end agrees. If the
port doesn't receive any packets from far end,
then after some timeout period the port forms a
channel by itself. If the status is set to
autoSilent(6), the port does not initiate a
request to become a channel, but will do so if it
receives a request to become a channel from the
far end. If the port doesn't receive any request,
then after some timeout period the port forms a
channel by itself."
DEFVAL { auto }
::= { portChannelEntry 4 }
portChannelOperStatus OBJECT-TYPE
SYNTAX INTEGER { channelling(1), notChannelling(2) }
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "Indicates whether the ports current channelling
operational status is channel or not."
::= { portChannelEntry 5 }
portChannelNeighbourDeviceId OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (6))
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "Indicates the neighbors device id."
::= { portChannelEntry 6 }
portChannelNeighbourPortId OBJECT-TYPE
SYNTAX INTEGER (1..2147483647)
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "Indicates the neighbor ports' Id."
::= { portChannelEntry 7 }
portChannelProtInPackets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "Indicates the number of protocol packets received
on the ports."
::= { portChannelEntry 8 }
portChannelProtOutPackets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "Indicates the number of protocol packets
transmitted on the ports."
::= { portChannelEntry 9 }
portChannelIfIndex OBJECT-TYPE
SYNTAX INTEGER (1..2147483647)
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "The value of the instance of the ifIndex object
defined in MIB-II, for the interface corresponding
to the channel which the port belongs to. This
object will have a non zero value if its
portChannelOperStatus is channelling and the link
of this port is up."
::= { portChannelEntry 10 }
-- the port capability
-- Implementation of the port capability group is optional, but within
-- the group all the elements are current.
portCpbTable OBJECT-TYPE
SYNTAX SEQUENCE OF PortCpbEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A list of port capability entries. The number of
entries is determined by the number of modules in
the chassis and the number of ports on each
module."
::= { portCpbGrp 1 }
portCpbEntry OBJECT-TYPE
SYNTAX PortCpbEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Entry containing port capability information for
a particular port on a module."
INDEX { portCpbModuleIndex, portCpbPortIndex }
::= { portCpbTable 1 }
PortCpbEntry ::=
SEQUENCE {
portCpbModuleIndex
INTEGER,
portCpbPortIndex
INTEGER,
portCpbSpeed
BITS,
portCpbDuplex
BITS,
portCpbTrunkEncapsulationType
BITS,
portCpbTrunkMode
BITS,
portCpbChannel
DisplayString,
portCpbBroadcastSuppression
BITS,
portCpbFlowControl
BITS,
portCpbSecurity
INTEGER,
portCpbVlanMembership
BITS,
portCpbPortfast
INTEGER,
portCpbUdld
INTEGER,
portCpbInlinePower
BITS,
portCpbAuxiliaryVlan
BITS,
portCpbSpan
BITS,
portCpbCosRewrite
INTEGER,
portCpbTosRewrite
BITS,
portCpbCopsGrouping
OCTET STRING,
portCpbDot1x
INTEGER,
portCpbIgmpFilter
INTEGER
}
portCpbModuleIndex OBJECT-TYPE
SYNTAX INTEGER (1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "An index value that uniquely identifies the
module where this port is located (see
portModuleIndex)."
::= { portCpbEntry 1 }
portCpbPortIndex OBJECT-TYPE
SYNTAX INTEGER (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "An index value that uniquely identifies this port
within a module (see portIndex)."
::= { portCpbEntry 2 }
portCpbSpeed OBJECT-TYPE
SYNTAX BITS { auto(0),
mbps4(1),
mbps10(2),
mbps16(3),
mbps45(4),
mbps100(5),
mbps155(6),
mbps400(7),
mbps622(8),
mbps1000(9),
mbps1dot544(10), -- 1.544 mbps
mbps2(11), -- 2 mbps
mbps2dot048(12), -- 2.048 mbps
kps64(13), -- 64 kps
mbps10000(14) } -- 10 Gbps
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the port speed capability of a port."
::= { portCpbEntry 3 }
portCpbDuplex OBJECT-TYPE
SYNTAX BITS { half(0),
full(1),
auto(2),
hdx(3),
fdx(4) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the duplex capability of a port.
The fdx(4) is specially for tokenring full-duplex
and hdx(3) is specially for tokenring
half-duplex."
::= { portCpbEntry 4 }
portCpbTrunkEncapsulationType OBJECT-TYPE
SYNTAX BITS { lane(0),
dot10(1),
dot1Q(2),
isl(3),
negotiate(4) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the VLAN encapsulation capability of a
port, The dot10(1) is for 801.10 and dot1q(2) is
for 801.1Q."
::= { portCpbEntry 5 }
portCpbTrunkMode OBJECT-TYPE
SYNTAX BITS { on(0),
off(1),
desirable(2),
auto(3),
onNoNegotiate(4) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the trunk capability of a port."
::= { portCpbEntry 6 }
portCpbChannel OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..128))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the channelling capability of a port."
::= { portCpbEntry 7 }
portCpbBroadcastSuppression OBJECT-TYPE
SYNTAX BITS { pps(0),
percentage(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the broadcast suppression capability of
a port. The pps(0) is for ports capable of
specifying suppression in packets per second and
percentage(1) is for ports capable of specifying
suppression in terms of percentage of bandwidth."
::= { portCpbEntry 8 }
portCpbFlowControl OBJECT-TYPE
SYNTAX BITS { receiveOff(0),
receiveOn(1),
receiveDesired(2),
sendOff(3),
sendOn(4),
sendDesired(5) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the flow control capability of a port."
::= { portCpbEntry 9 }
portCpbSecurity OBJECT-TYPE
SYNTAX INTEGER { yes(1), no(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates whether a port supports security."
::= { portCpbEntry 10 }
portCpbVlanMembership OBJECT-TYPE
SYNTAX BITS { static(0),
dynamic(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the vlan membership capability of a
port."
::= { portCpbEntry 11 }
portCpbPortfast OBJECT-TYPE
SYNTAX INTEGER { yes(1), no(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates whether a port supports portfast."
::= { portCpbEntry 12 }
portCpbUdld OBJECT-TYPE
SYNTAX INTEGER {
yes(1),
no(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates whether the port is capable of UDLD
(UniDirectional Link Detection) or not."
::= { portCpbEntry 13 }
portCpbInlinePower OBJECT-TYPE
SYNTAX BITS {
auto(0),
on(1),
off(2),
static(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicate the inline power capability of a port.
'auto' denotes the ability that the switch
automatically determines whether or not power
should be provided. 'on' denotes the ability to
manually turn on inline power.
'off' denotes the ability to manually turn off
inline power. 'static' denotes the ability to
preallocate power for a port."
::= { portCpbEntry 14 }
portCpbAuxiliaryVlan OBJECT-TYPE
SYNTAX BITS {
vlanNo (0),
untagged (1),
dot1p (2),
none (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicate the voice vlan capability of a port."
::= { portCpbEntry 15 }
portCpbSpan OBJECT-TYPE
SYNTAX BITS {
source(0),
destination(1),
reflector(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates port span capabilities.
source(0) denotes the capability of being SPAN
source destination(1) denotes the capability of
being SPAN destination, reflector(2) denotes the
capability of being SPAN reflector."
::= { portCpbEntry 16 }
portCpbCosRewrite OBJECT-TYPE
SYNTAX INTEGER { yes(1), no(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates whether a port supports CoS rewrite."
::= { portCpbEntry 17 }
portCpbTosRewrite OBJECT-TYPE
SYNTAX BITS { dscp(0),
ipPrecedence(1) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates the ToS rewrite capability of a port.
dscp(0) denotes the port capability to classify
packets according to the DSCP.
ipPrecedence(1) denotes the port capability to
classify packets according to the IP Precedence."
::= { portCpbEntry 18 }
portCpbCopsGrouping OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..8))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The set of ports on a module that are configured
together as far as the Differentiated Services
Cops feature is concerned. Each Octet within the
value of this object specifies a set of eight
ports, with the first octet specifying ports 1
through 8, the second octet specifying ports 9
through 16, etc. Within each octet, the most
significant bit represents the lowest numbered
port, and the least significant bit represents
the highest numbered port. Thus, each port is
represented by a single bit within the value of
this object. If that bit has a value of `1' then
that port is included in the set of Cops
grouping."
::= { portCpbEntry 19 }
portCpbDot1x OBJECT-TYPE
SYNTAX INTEGER { yes(1), no(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates whether a port supports 802.1x."
::= { portCpbEntry 20 }
portCpbIgmpFilter OBJECT-TYPE
SYNTAX INTEGER { yes(1), no(2) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates whether a port supports IGMP filter."
::= { portCpbEntry 21 }
-- The PORT Top "N" Group
--
-- The Port Top N group is used to prepare reports that
-- describe the ports that top a list ordered by one of
-- their statistics. Therefore, the sampling base is on
-- the ports in this monitored device system. The data
-- source is from all the ports in this monitored device
-- system so it is not necessary to specify the data
-- source in the control table.
-- The available statistics are samples of one of their
-- base statistics, over an interval specified by the
-- management station. Thus, these statistics are rate
-- based. The management station also selects how many such
-- ports are reported.
-- The portTopNControlTable is used to initiate the
-- generation of such a report. The management station
-- may select the parameters of such a report, such as
-- which statistic, how many ports, port types, and the start
-- and stop times of the sampling.
-- When the report is prepared, entries are created in the
-- portTopNTable associated with the relevant
-- portTopNControlEntry. These entries are static for
-- each report after it has been prepared.
portTopNControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF PortTopNControlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A list of top N port control entries."
::= { portTopNGrp 1 }
portTopNControlEntry OBJECT-TYPE
SYNTAX PortTopNControlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A set of parameters that control the creation of
a report of the top N ports according to several
metrics.
For example, an instance of the portTopNDuration
object might be named portTopNDuration.3"
INDEX { portTopNControlIndex }
::= { portTopNControlTable 1 }
PortTopNControlEntry ::=
SEQUENCE {
portTopNControlIndex
INTEGER,
portTopNRateBase
INTEGER,
portTopNType
INTEGER,
portTopNMode
INTEGER,
portTopNReportStatus
INTEGER,
portTopNDuration
INTEGER,
portTopNTimeRemaining
INTEGER,
portTopNStartTime
TimeTicks,
portTopNRequestedSize
INTEGER,
portTopNGrantedSize
INTEGER,
portTopNOwner
OwnerString,
portTopNStatus
RowStatus
}
portTopNControlIndex OBJECT-TYPE
SYNTAX INTEGER (1..5)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "An index that uniquely identifies an entry
in the portTopNControl table. Each such
entry defines one top N report."
::= { portTopNControlEntry 1 }
portTopNRateBase OBJECT-TYPE
SYNTAX INTEGER {
portTopNUtilization(1),
portTopNIOOctets(2),
portTopNIOPkts(3),
portTopNIOBroadcastPkts(4),
portTopNIOMulticastPkts(5),
portTopNInErrors(6),
portTopNBufferOverflow(7)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The variable for all ports in this system
based on which portTopNTable/report is ordered.
This object may not be modified if the associated
portTopNStatus object is equal to active(1)."
DEFVAL { portTopNUtilization }
::= { portTopNControlEntry 2 }
portTopNType OBJECT-TYPE
SYNTAX INTEGER {
portTopNAllPorts(1),
portTopNEthernet(2),
portTopNFastEthernet(3),
portTopNGigaEthernet(4),
portTopNTokenRing(5),
portTopNFDDI(6),
portTopNAllEthernetPorts(7),
portTopN10GigaEthernet(8)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The sampling port type.
This object may not be modified if the associated
portTopNStatus object is equal to active(1)."
DEFVAL { portTopNAllPorts }
::= { portTopNControlEntry 3 }
portTopNMode OBJECT-TYPE
SYNTAX INTEGER {
portTopNForeground(1),
portTopNBackground(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The running mode of this portTopN control entry.
portTopNForeground (1) means when
portTopNTimeRemaining reaches to 0, the report
will show on the CLI at once and it won't be kept
in the portTopNTable. portTopNBackground (2) means
the report will not show on the CLI it will be
kept in the portTopNTable.
This object may not be modified if the associated
portTopNStatus object is equal to active(1)."
DEFVAL { portTopNBackground }
::= { portTopNControlEntry 4 }
portTopNReportStatus OBJECT-TYPE
SYNTAX INTEGER {
progressing(1),
ready(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The report status of this portTopN control entry.
Progressing (1) means that the report of this
portTopN control entry is still in progress. The
management station can poll this mib object to
check the report data is available or not.
Ready (2) means the report is available."
::= { portTopNControlEntry 5 }
portTopNDuration OBJECT-TYPE
SYNTAX INTEGER (0|10..999)
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The sampling interval in seconds during which
statistics are collected for this report.
When this is set a value and the corresponding
portTopNControlEntry is valid, the
portTopNTimeRemaining object shall be set to the
same value.
portTopNTimeRemaining starts at the same value as
portTopNDuration and counts down as the collection
goes on.
If this object is set to be zero, it will do the
collection immediately. And the collecting report
value should be the absolute counter value."
DEFVAL { 30 }
::= { portTopNControlEntry 6 }
portTopNTimeRemaining OBJECT-TYPE
SYNTAX INTEGER(1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The number of seconds left in the report
currently being collected. When portTopNDuration
object is modified by the management station, a
new collection is started, possibly aborting a
currently running report. The new value is used as
the requested duration of this report, which is
loaded from the associated portTopNDuration
object.
When this object is a non-zero value, any
associated portTopNEntries shall be made
inaccessible by the monitor.
While the value of this object is non-zero and the
corresponding portTopNControlENtry is valid, it
decrements by one per second until it reaches
zero. During this time, all associated
portTopNEntries shall remain inaccessible. At
the time that this object decrements to zero, the
report is made accessible in the portTopNTable.
Thus, the portTopN table is to be created only at
the end of the collection interval."
::= { portTopNControlEntry 7 }
portTopNStartTime OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The value of sysUpTime when this top N report was
last started. In other words, this is the time
that the associated portTopNTimeRemaining object
was modified to start the requested report."
::= { portTopNControlEntry 8 }
portTopNRequestedSize OBJECT-TYPE
SYNTAX INTEGER(1..65535)
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The maximum number of ports requested for the top
N entry.
When this object is created or modified, the value
of portTopNGrantedSize is set as closely to this
object as is possible for the particular
implementation and available resources.
Valid value for this object is 1 to maximum number
of physical ports. The default value is 20 ports."
DEFVAL { 20 }
::= { portTopNControlEntry 9 }
portTopNGrantedSize OBJECT-TYPE
SYNTAX INTEGER(1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The maximum number of ports in the top N table.
When the associated portTopNRequestedSize object
is created or modified, the value of this object
should be set as closely to the requested value as
is possible for the particular implementation and
available resources. The value must not be lowered
except as a result of a set to the associated
portTopNRequestedSize object.
Ports with the highest value of portTopNRateBase
shall be placed in this table in decreasing order
of this rate until there is no more room or until
there are no more ports."
::= { portTopNControlEntry 10 }
portTopNOwner OBJECT-TYPE
SYNTAX OwnerString
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The entity that configured this entry and is
therefore using the resources assigned to it."
::= { portTopNControlEntry 11 }
portTopNStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The status of this portTopNControl entry.
The Management station sends the user set values
with a portTopNStatus value of createAndGo(4).
When the agent receives it the collection of the
report starts.
When the portTopNReportStatus is ready(2) the user
can get the reports (portTopNTable).
For the current implementation createAndWait(5)
will not be supported.
There can be only 5 rows in the control table."
::= { portTopNControlEntry 12 }
portTopNTable OBJECT-TYPE
SYNTAX SEQUENCE OF PortTopNEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A list of top N port entries."
::= { portTopNGrp 2 }
portTopNEntry OBJECT-TYPE
SYNTAX PortTopNEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A set of statistics for a port that is part of a
top N report. For example, an instance of the
portTopNRateBase object might be named
portTopNUtilization.3.10"
INDEX { portTopNControlIndex, portTopNIndex }
::= { portTopNTable 1 }
PortTopNEntry ::=
SEQUENCE {
portTopNIndex
INTEGER,
portTopNModuleNumber
INTEGER,
portTopNPortNumber
INTEGER,
portTopNUtilization
INTEGER,
portTopNIOOctets
Counter64,
portTopNIOPkts
Counter64,
portTopNIOBroadcast
Counter64,
portTopNIOMulticast
Counter64,
portTopNInErrors
Counter32,
portTopNBufferOverFlow
Counter32
}
portTopNIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "An index that uniquely identifies an entry in
the portTopN table among those in the same report.
This index is between 1 and N, where N is the
portTopNGrantedSize of ports with the highest
portTopNRateBase. Increasing values of
portTopNIndex shall be assigned to entries with
decreasing values of portTopNRateBase until index
N is assigned to the entry with the lowest value
of portTopNRateBase or there are no more
portTopNEntries."
::= { portTopNEntry 1 }
portTopNModuleNumber OBJECT-TYPE
SYNTAX INTEGER (1..20)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The module number of the port counter data
entry."
::= { portTopNEntry 2 }
portTopNPortNumber OBJECT-TYPE
SYNTAX INTEGER (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The port number of the port counter data entry."
::= { portTopNEntry 3 }
portTopNUtilization OBJECT-TYPE
SYNTAX INTEGER(1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The utilization of the port in the system.
The utilization is computed in the following
methods:
Ethernet Utilization: (If Full Duplex, multiply by 2)
10 Mbps I/O-pkts * (9.6 + 6.4) + (0.8 * I/O-Bytes)
Ethernet Util = -----------------------------------------
Interval * 10,000
where 9.6 is interframe gap of Ethernet
6.4 is preamble of Ethernet
10,000 is 10Mbps
100 Mbps I/O-pkts * (96 + 64) + (8 * I/O-Bytes)
Ethernet Util = --------------------------------------
Interval * 1,000,000
1000 Mbps I/O-pkts * (96 + 64) + (8 * I/O-Bytes)
Ethernet Util = --------------------------------------
Interval * 10,000,000
All other I/O-pkts * (9.6 + 6.4) + (0.8 * I/O-Bytes)
Ethernet Util = ------------------------------------------
Interval * N * 1,000
(where N is N Mbps)
Token Ring Utilization:
(Assuming that Octets is from AC byte through FCS)
4 Mbps Pkts * 32 + (8 * Octets)
Token Ring Util = 100 * ------------------------
Interval * 4,000,000
where 32 is bits in SD, ED, FS and IFG
16 Mbps Pkts * 64 + (8 * Octets)
Token Ring Util = 100 * ------------------------
Interval * 16,000,000
where 64 is bits in SD, ED, FS and IFG
FDDI Utilization:
I/O-Pkts * (64 + 8 + 32 + 16) + (8 * I/O-Bytes)
FDDI Util = ----------------------------------------------
Interval * 100,000,000
where 64 is Preamble of FDDI,
8 is the Start Delimiter (SD) of FDDI,
32 is the CRC, and
16 is the End of Frame Sequence (EFS) of FDDI."
::= { portTopNEntry 4 }
portTopNIOOctets OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Input and Output octets of the port in the
system."
::= { portTopNEntry 5 }
portTopNIOPkts OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Input and Output packets of the port in the
system."
::= { portTopNEntry 6 }
portTopNIOBroadcast OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Input and Output broadcast packets of the
port in the system."
::= { portTopNEntry 7 }
portTopNIOMulticast OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Input and Output multicast packets of the
port in the system."
::= { portTopNEntry 8 }
portTopNInErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Input error packets of the port in the
system."
::= { portTopNEntry 9 }
portTopNBufferOverFlow OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The number of buffer overflow of the port in
the system."
::= { portTopNEntry 10 }
-- the multiple default gateway group
-- Implementation of the multiple default gateway group is optional,
-- but within the group all the elements are current. If the multiple
-- default gateway feature is supported, the entire group should be
-- implemented.
mdgGatewayTable OBJECT-TYPE
SYNTAX SEQUENCE OF MdgGatewayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table lists a maximum of 3 MDG gateways."
::= { mdgGrp 1 }
mdgGatewayEntry OBJECT-TYPE
SYNTAX MdgGatewayEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A MDG gateway table entry."
INDEX { mdgGatewayAddr }
::= { mdgGatewayTable 1 }
MdgGatewayEntry ::=
SEQUENCE {
mdgGatewayAddr
IpAddress,
mdgGatewayType
INTEGER
}
mdgGatewayAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The IP address of a default gateway."
::= { mdgGatewayEntry 1 }
mdgGatewayType OBJECT-TYPE
SYNTAX INTEGER {
invalid(1), -- remove this entry
primary(2), -- the primary entry
other(3) -- a lower priority entry
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION "To add a new entry to the mdgGatewayTable, set
this object to primary(2) or other(3) for an IP
address which is not already in the table. The
primary entry will be used first, if it is
reachable. Otherwise, one of the other entries
will be used. Setting one entry to primary(2)
causes any previous primary entry to change to
other(3). To remove an entry from the table, set
this object to invalid(1). Changing an existing
entry from primary(2) to other(3) is not allowed.
If the value of this object is updated, the
corresponding entry of the ipRouteTable (mibII)
will be updated and vice versa."
::= { mdgGatewayEntry 2 }
-- the RADIUS group
-- Implementation of the RADIUS group is optional, but within the group
-- all the elements are current. If the RADIUS feature is implemented,
-- the entire group should be implemented.
radiusLoginAuthentication OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2),
enabledForTelnetOnly(3),
enabledForConsoleOnly(4)
}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION "Indicates whether the login authentication using
RADIUS feature is enabled or disabled for console
and/or telnet sessions.
Setting this object to enabled(1), the login
authentication using RADIUS feature is enabled for
both console and telnet sessions.
Setting this object to disabled(2), the login
authentication using RADIUS feature is disabled
for both console and telnet sessions.
Setting this object to enabledForTelnetOnly(3),the
login authentication using RADIUS feature is
enabled only for telnet sessions, but disabled
for console session.
Setting this object to enabledForConsoleOnly(4),
the login authentication using RADIUS feature is
enabled only for console sessions, but disabled
for telnet sessions.
This object is deprecated and replaced by
cacPriorityTable in CISCO-AAA-CLIENT-MIB."
DEFVAL { disabled }
::= { radiusGrp 1 }
radiusEnableAuthentication OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2),
enabledForTelnetOnly(3),
enabledForConsoleOnly(4)
}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION "Indicates whether the enable authentication using
the RADIUS feature is enabled or disabled for
Console and telnet sessions.
Setting this object to enabled(1), the enable
authentication using RADIUS feature is enabled for
both console and telnet sessions.
Setting this object to disabled(2), the enable
authentication using RADIUS feature is disabled
for both console and telnet sessions.
Setting this object to enabledForTelnetOnly(3),
the enable authentication using RADIUS feature is
enabled only for telnet sessions, but disabled for
console sessions.
Setting this object to enabledForConsoleOnly(4),
the enable authentication using RADIUS feature is
enabled only for console sessions, but disabled
for telnet sessions.
This object is deprecated and replaced by
cacPriorityTable in CISCO-AAA-CLIENT-MIB."
DEFVAL { disabled }
::= { radiusGrp 2 }
radiusDeadtime OBJECT-TYPE
SYNTAX INTEGER (0..1440)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Indicates the length of time in minutes that
the system will mark the server dead when a RADIUS
server does not respond to an authentication
request. During the interval of the dead time, any
authentication request that comes up would not be
sent to that RADIUS server that was marked as
dead. The default value of 0 means that the
RADIUS servers will not be marked dead if they
do not respond."
DEFVAL { 0 }
::= { radiusGrp 3 }
radiusAuthKey OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..64))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The key used in encrypting the packets passed
between the RADIUS server and the client. This key
must match the one configured on the server.
Note that this item is only accessible when using
the community string defined in sysCommunityRwa."
-- DEFVAL { NULL }
::= { radiusGrp 4 }
radiusTimeout OBJECT-TYPE
SYNTAX INTEGER (1..1000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "This is the time in seconds between
retransmissions to the RADIUS server."
DEFVAL { 5 }
::= { radiusGrp 5 }
radiusRetransmits OBJECT-TYPE
SYNTAX INTEGER (1..100)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Indicates number of times the RADIUS server
should be tried before giving up on the server."
DEFVAL { 2 }
::= { radiusGrp 6 }
radiusServerTable OBJECT-TYPE
SYNTAX SEQUENCE OF RadiusServerEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION "This table lists a maximum of 3 RADIUS servers.
This object is deprecated and replaced by
crRadiusServerTable in CISCO-RADIUS-MIB."
::= { radiusGrp 7 }
radiusServerEntry OBJECT-TYPE
SYNTAX RadiusServerEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION "A RADIUS server table entry."
INDEX { radiusServerAddr }
::= { radiusServerTable 1 }
RadiusServerEntry ::=
SEQUENCE {
radiusServerAddr
IpAddress,
radiusServerAuthPort
INTEGER,
radiusServerType
INTEGER
}
radiusServerAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "The IP address of a RADIUS Server."
::= { radiusServerEntry 1 }
radiusServerAuthPort OBJECT-TYPE
SYNTAX INTEGER (0..65535)
MAX-ACCESS read-create
STATUS deprecated
DESCRIPTION "This is the destination UDP port number to which
RADIUS messages should be sent. The RADIUS server
will not be used for authentication if this port
number is 0."
REFERENCE "RFC2138, Implementation Note."
DEFVAL { 1812 }
::= { radiusServerEntry 2 }
radiusServerType OBJECT-TYPE
SYNTAX INTEGER {
invalid(1), -- remove this entry
primary(2), -- the primary entry
other(3) -- a lower priority entry
}
MAX-ACCESS read-create
STATUS deprecated
DESCRIPTION "To add a new entry to the radiusServerTable, set
this object to primary(2) or other(3) for an IP
address which is not already in the table. The
primary entry will be used first, if it is
reachable. Otherwise, one of the other entries
will be used. Setting one entry to primary(2)
causes any previous primary entry to change to
other(3). To remove an entry from the table,
set this object to invalid(1)."
::= { radiusServerEntry 3 }
-- the traceRoute group
-- Implementation of the traceRoute group is optional, but within the
-- group all the elements are current. If the trace route feature is
-- supported, the entire group should be implemented.
traceRouteMaxQueries OBJECT-TYPE
SYNTAX INTEGER (1..20)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Maximum number of query entries allowed to be
outstanding at any time, in the
traceRouteQueryTable.
The typical value for this object is 5."
::= { traceRouteGrp 1}
traceRouteQueryTable OBJECT-TYPE
SYNTAX SEQUENCE OF TraceRouteQueryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A control table used to query the information
about each gateway along the path to a host by
specifying retrieval criteria for the host. The
resulting data for each instance of a query in
this table is returned in the traceRouteDataTable.
The maximum number of entries (rows) in this table
cannot exceed the value returned by
traceRouteMaxQueries."
::= { traceRouteGrp 2 }
traceRouteQueryEntry OBJECT-TYPE
SYNTAX TraceRouteQueryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A conceptual row of the traceRouteQueryTable used
to setup retrieval criteria to search for gateways
belongs to the path to a particular host
identified by its IP address. The actual search
is started by setting the value of
traceRouteQueryStatus to valid(1)."
INDEX { traceRouteQueryIndex }
::= { traceRouteQueryTable 1 }
TraceRouteQueryEntry ::=
SEQUENCE {
traceRouteQueryIndex
INTEGER,
traceRouteHost
DisplayString,
traceRouteQueryDNSEnable
INTEGER,
traceRouteQueryWaitingTime
INTEGER,
traceRouteQueryInitTTL
INTEGER,
traceRouteQueryMaxTTL
INTEGER,
traceRouteQueryUDPPort
INTEGER,
traceRouteQueryPacketCount
INTEGER,
traceRouteQueryPacketSize
INTEGER,
traceRouteQueryTOS
INTEGER,
traceRouteQueryResult
INTEGER,
traceRouteQueryTime
TimeTicks,
traceRouteQueryOwner
DisplayString,
traceRouteQueryStatus
INTEGER
}
traceRouteQueryIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Object which specifies an unique entry in the
traceRouteQueryTable."
::= { traceRouteQueryEntry 1 }
traceRouteHost OBJECT-TYPE
SYNTAX DisplayString(SIZE(0..255))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Network(IP) address in dotted decimal format or
the DNS hostname of the host which is tracerouted."
::= { traceRouteQueryEntry 2 }
traceRouteQueryDNSEnable OBJECT-TYPE
SYNTAX INTEGER{ enabled(1),
disabled(2) }
MAX-ACCESS read-create
STATUS current
DESCRIPTION "If this value of this object is true, the
traceroute operation will do a DNS lookup for each
hop on the path, so the corresponding instance of
the traceRouteDataTable will contain the host name
and the ip address; otherwise, that instance only
contains the ip address."
DEFVAL { enabled }
::= { traceRouteQueryEntry 3 }
traceRouteQueryWaitingTime OBJECT-TYPE
SYNTAX INTEGER (1..300)
UNITS "seconds"
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The trace route waiting time in seconds for an
ICMP response message."
DEFVAL { 5 }
::= { traceRouteQueryEntry 4 }
traceRouteQueryInitTTL OBJECT-TYPE
SYNTAX INTEGER(1..255)
MAX-ACCESS read-create
STATUS current
DESCRIPTION "If this value of this object is set, it allows
users skip processing for gateways that are less
than traceRouteQueryInitTTL away by sending
datagram with the value of this object instead of
the default value of one."
DEFVAL { 1 }
::= { traceRouteQueryEntry 5 }
traceRouteQueryMaxTTL OBJECT-TYPE
SYNTAX INTEGER (1..255)
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The maximum TTL value used in outgoing packets."
DEFVAL { 30 }
::= { traceRouteQueryEntry 6}
traceRouteQueryUDPPort OBJECT-TYPE
SYNTAX INTEGER(1..65535)
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The base UDP destination port is used in the
traceroute datagrams. This value of this object is
often larger than 30,000 to make it improbable
that this port is used (this causes the
destination host's UDP module to generate an ICMP
port unreachable so the traceroute operation
knows when the operation is accomplished).
The traceroute operation will increment this value
of this object each time it sends a datagram. This
object should be used in the unlikely event that
the destination port is listening to a port in the
default traceroute port range."
DEFVAL { 33434 }
::= { traceRouteQueryEntry 7 }
traceRouteQueryPacketCount OBJECT-TYPE
SYNTAX INTEGER(1..1000)
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Specifies the number of traceroute packets to
send to the target host in this sequence."
DEFVAL { 3 }
::= { traceRouteQueryEntry 8 }
traceRouteQueryPacketSize OBJECT-TYPE
SYNTAX INTEGER(0..1420)
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Specifies the size of traceroute packets to send
to the target host in this sequence. "
DEFVAL { 0 }
::= { traceRouteQueryEntry 9 }
traceRouteQueryTOS OBJECT-TYPE
SYNTAX INTEGER(0..255)
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The type of service to be set in the IP header of
the outgoing packets.This value can set to see if
different types-of-service result in different
paths. Not all values of TOS are legal or
meaningful (see the IP spec for definitions.
Useful values are probably 16 (low delay) and 8
(high throughput)."
DEFVAL { 0 }
::= { traceRouteQueryEntry 10 }
traceRouteQueryResult OBJECT-TYPE
SYNTAX INTEGER(-1..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The result status of the query. Possible values
are:
-1 -Either the query has not been initiated or the
agent is busy processing this query instance. Time
to completion of the query processing depends on
the complexity of the query and the number of
matches that satisfy this query.
0..2147483647 - The search has ended and this is
the number of rows in the traceRouteDataTable,
resulting from this query."
::= { traceRouteQueryEntry 21}
traceRouteQueryTime OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The value of sysUpTime at the time when the query
is configured."
::= { traceRouteQueryEntry 22 }
traceRouteQueryOwner OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..50))
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The manager entity that configured this entry and
is therefore using the resources assigned to it."
::= { traceRouteQueryEntry 23 }
traceRouteQueryStatus OBJECT-TYPE
SYNTAX INTEGER {valid(1), invalid(2) }
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The status object used to manage rows in this
table.
When set this object to valid(1), the query is
initiated. Once initiated, all the read-write
objects of this table can't be modified. To remove
an entry from the table, set this object to
invalid(2)."
::= { traceRouteQueryEntry 24 }
-- The Trace Route result table.
traceRouteDataTable OBJECT-TYPE
SYNTAX SEQUENCE OF TraceRouteDataEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table containing information about the gateway
belongs to the path to the host corresponding to
all the completed queries setup in the
traceRouteQueryTable."
::= { traceRouteGrp 3 }
traceRouteDataEntry OBJECT-TYPE
SYNTAX TraceRouteDataEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A conceptual row of the traceRouteDataTable used
to return information about all the gateway
belongs to the host of which search criteria is
corresponding instance of the
traceRouteQueryTable."
INDEX { traceRouteQueryIndex, traceRouteDataIndex }
::= { traceRouteDataTable 1 }
TraceRouteDataEntry ::=
SEQUENCE {
traceRouteDataIndex
INTEGER,
traceRouteDataGatewayName
DisplayString,
traceRouteDataGatewayIp
IpAddress,
traceRouteDataRtt
INTEGER,
traceRouteDataHopCount
INTEGER,
traceRouteDataErrors
INTEGER
}
traceRouteDataIndex OBJECT-TYPE
SYNTAX INTEGER(1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Object which specifies an unique entry in the
traceRouteDataTable."
::= { traceRouteDataEntry 1 }
traceRouteDataGatewayName OBJECT-TYPE
SYNTAX DisplayString(SIZE(0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The DNS name of the gateway if available."
::= { traceRouteDataEntry 2 }
traceRouteDataGatewayIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The ip address of the gateway. If the traceroute
packet was sent and timed-out, the ip address is
set to 0.0.0.0."
::= { traceRouteDataEntry 3 }
traceRouteDataRtt OBJECT-TYPE
SYNTAX INTEGER(1..65535)
UNITS "milliseconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The round trip time of the current packet that
have been sent in this sequence."
::= { traceRouteDataEntry 4 }
traceRouteDataHopCount OBJECT-TYPE
SYNTAX INTEGER(1..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The number of hop starting from the place where
the traceroute operation is initialized to the
gateway which has the traceRouteDataGatewayIp."
::= { traceRouteDataEntry 5 }
traceRouteDataErrors OBJECT-TYPE
SYNTAX INTEGER {
icmpUnreachNet(1), -- bad net
icmpUnreachHost(2), -- bad host
icmpUnreachProtocol(3), -- bad protocol
icmpUnreachPort(4), -- bad port
icmpUnreachNeedFrag(5), -- IP defragment caused
-- drop
icmpUnreachSrcFail(6), -- src route failed
icmpUnreachNoNet(7), -- no such network
icmpUnreachNoHost(8), -- no such host
icmpUnreachHostIsolated(9), -- host isolated
icmpUnreachNetProhib(10),
-- dod net admin prohibited
icmpUnreachProhib(11),
-- dod host admin prohibit
icmpUnreachNetTos(12),
-- net and tos unreachable
icmpUnreachHostTos(13),
-- host and tos unreachable
icmpUnreachAdmin(14),
-- administratively prohibited
icmpUnreachHostPrec(15), -- host precedence
icmpUnreachPrecedence(16), -- precedence cutoff
icmpUnknown(17), -- unknown error
icmpTimeOut(18), -- time out
icmpTTLExpired(19) -- ttl expired
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The error of the traceroute operation."
::= { traceRouteDataEntry 6 }
-- the fileCopy group
-- Implementation of the file group is current for all Cisco Workgroup
-- Stack products which implement tftp/rcp upload/download functions
-- or local file copy.
fileCopyProtocol OBJECT-TYPE
SYNTAX INTEGER { tftp (1),
rcp (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The protocol to be used for any remote copy.
If the config file transfer is to occur locally on
the SNMP agent, the method of transfer is left up
to the implementation, and is not restricted to
the protocols above.
The value of this object can not be changed when
the fileCopyResult object has the value of
inProgress(1)."
DEFVAL { tftp }
::= { fileCopyGrp 1 }
fileCopyRemoteServer OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The IP address or the host name of the tftp/rcp
remote server from (or to) which to copy the file.
If the copy operation is local on the SNMP agent,
this object is not applicable.
The value of this object can not be changed when
the fileCopyResult object has the value of
inProgress(1)."
::= { fileCopyGrp 2 }
fileCopySrcFileName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The source file name (including the path, if
applicable) of the file. The accepted value of
this object is 'cfg1' or 'cfg2' when the requested
action is one of the following:
copyConfigFromFlashToRuntime(8), and
copyConfigFileFromFlashToHost(11).
The value of this object can not be changed when
the fileCopyResult object has the value of
inProgress(1)."
::= { fileCopyGrp 3 }
fileCopyDstFileName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The destination file name (including the path, if
applicable) of the file. The accepted value of
this object is 'cfg1' or 'cfg2' when the requested
action is one of the following:
copyConfigFromRuntimeToFlash(9),
copyConfigFileFromHostToFlash(10).
The value of this object can not be changed when
the fileCopyResult object has the value of
inProgress(1)."
::= { fileCopyGrp 4 }
fileCopyModuleNumber OBJECT-TYPE
SYNTAX INTEGER(0..16)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The module number specified in the copy
operation.
If the value of this object is 0 and the
fileCopyAction object has the value of
copyImageFromHostToFlash(4), the switch will do
multiple download to the modules with matching
image type. It is left to the SNMP agent to allow
the individual modules to be reset with the
downloaded images or not.
The value of this object can not be changed when
the fileCopyResult object has the value of
inProgress(1)."
::= { fileCopyGrp 5 }
fileCopyUserName OBJECT-TYPE
SYNTAX DisplayString(SIZE (1..40))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Remote user name for copy via rcp protocol. This
object must be specified when the
fileCopyProtocol is rcp."
::= { fileCopyGrp 6 }
fileCopyAction OBJECT-TYPE
SYNTAX INTEGER {
other(1), -- none of the following
copyConfigFromHostToRuntime(2),
copyConfigFromRuntimeToHost(3),
copyImageFromHostToFlash(4),
copyImageFromFlashToHost(5),
copyConfigFromFlashToRuntime(8),
copyConfigFromRuntimeToFlash(9),
copyConfigFileFromHostToFlash(10),
copyConfigFileFromFlashToHost(11),
copyTechReportFromRuntimeToHost(12)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Setting this object to one of the acceptable
values will initiate the requested action using
the information provided by fileCopyProtocol,
fileCopyRemoteServer, fileCopySrcFileName,
fileCopyDstFileName,fileCopyModuleNumber and
fileCopyUserName.
copyConfigFromHostToRuntime(2):
Copy the configuration file from host to
runtime configuration over the network through
tftp/rcp. This action will use
fileCopyProtocol, fileCopyRemoteServer,
fileCopySrcFileName, fileCopyModuleNumber,
and fileCopyUserName (if applicable).
copyConfigFromRuntimeToHost(3):
Copy the runtime configuration to host over the
network through tftp/rcp. This action will use
fileCopyProtocol, fileCopyRemoteServer,
fileCopyModuleNumber, fileCopyDstFileName,
fileCopyUserName (if applicable), and
fileCopyRuntimeConfigPart.
copyImageFromHostToFlash(4):
Copy the image from host to the flash over the
network through tftp/rcp. It is up to the
SNMP agent to reset and run the downloaded
image after copying. This action will use
fileCopyProtocol, fileCopyRemoteServer,
fileCopySrcFileName, fileCopyModuleNumber,
and fileCopyUserName (if applicable).
copyImageFromFlashToHost(5):
Copy the image from flash to host over the
switch through tftp/rcp. This action will use
fileCopyProtocol, fileCopyRemoteServer,
fileCopyDstFileName, fileCopyModuleNumber,
and fileCopyUserName (if applicable).
copyConfigFromFlashToRuntime(8):
Copy the configuration file to the runtime
configuration locally. This action can perform
only on the SUPG supervisor model and will
use fileCopySrcFileName ('cfg1' or 'cfg2').
copyConfigFromRuntimeToFlash(9):
Copy the runtime configuration to a
configuration file on the flash locally. This
action can perform only on the SUPG supervisor
model and will use fileCopyDstFileName ('cfg1'
or 'cfg2'), and fileCopyRuntimeConfigPart.
copyConfigFileFromHostToFlash(10):
Copy the configuration file from host to the
runtime configuration over the network through
tftp/rcp. This action can perform only on the
SUPG supervisor model and will use
fileCopyProtocol, fileCopyRemoteServer,
fileCopySrcFileName, fileCopyDstFileName,
fileCopyModuleNumber and fileCopyUserName
(if applicable).
copyConfigFileFromFlashToHost(11):
Copy the configuration file on the flash to
host over the network through tftp/rcp.
This action can perform only on the
SUPG supervisor model and will use
fileCopyProtocol, fileCopyRemoteServer,
fileCopySrcFileName, fileCopyDstFileName,
fileCopyModuleNumber and fileCopyUserName
(if applicable).
copyTechReportFromRuntimeToHost(12):
Copy the technical report of the system to
host over the network through tftp only. This
action will use fileCopyProtocol,
fileCopyRemoteServer, fileCopyModuleNumber,
and fileCopyDstFileName.
Setting this object to any other value results in
an error.
The value of this object can not be changed when
the fileCopyResult object has the value of
inProgress(1)."
::= { fileCopyGrp 7 }
fileCopyResult OBJECT-TYPE
SYNTAX INTEGER {
inProgress(1),
success(2),
noResponse(3),
tooManyRetries(4),
noBuffers(5),
noProcesses(6),
badChecksum(7),
badLength(8),
badFlash(9),
serverError(10),
userCanceled(11),
wrongCode(12),
fileNotFound(13),
invalidHost(14),
invalidModule(15),
accessViolation(16),
unknownStatus(17),
invalidStorageDevice(18),
insufficientSpaceOnStorageDevice(19),
insufficientDramSize(20),
incompatibleImage(21),
rcpError(22)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Contains the result of the last copy action
request.
If the value of fileCopyResult is rcpError(22),
then the detailed rcp error messages are contained
in fileCopyResultRcpErrorMessage."
::= { fileCopyGrp 8 }
fileCopyResultRcpErrorMessage OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Contains the detailed rcp error messages if the
value of fileCopyResult is rcpError(22) for the
last copy action request; otherwise, this MIB
object contains the empty string."
::= { fileCopyGrp 9 }
fileCopyRuntimeConfigPart OBJECT-TYPE
SYNTAX INTEGER {
all(1),
nonDefault(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Indicates the part of runtime configuration to be
copied. This object will only take effect when the
object value of fileCopyAction is one of the
following:
copyConfigFromRuntimeToHost(3),
copyConfigFromRuntimeToFlash(9).
all -- copy all the runtime configuration.
nonDefault --copy only the part of the runtime
configuration which is different from
the default configuration."
DEFVAL { all }
::= { fileCopyGrp 10 }
-- The voice Group
-- Voice Port Interface Configuration Table
voicePortIfConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF VoicePortIfConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A list of port entries. The number of entries is
determined by the number of modules in the chassis
and the number of ports with the voice port
interface configuration capability in the system."
::= { voiceGrp 1 }
voicePortIfConfigEntry OBJECT-TYPE
SYNTAX VoicePortIfConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Entry containing voice interface configuration
for a particular port."
INDEX { voicePortIfConfigModuleIndex,
voicePortIfConfigPortIndex }
::= { voicePortIfConfigTable 1 }
VoicePortIfConfigEntry ::=
SEQUENCE {
voicePortIfConfigModuleIndex INTEGER,
voicePortIfConfigPortIndex INTEGER,
voicePortIfDHCPEnabled TruthValue,
voicePortIfIpAddress IpAddress,
voicePortIfIpNetMask IpAddress,
voicePortIfTftpServerAddress IpAddress,
voicePortIfGatewayAddress IpAddress,
voicePortIfDnsServerAddress IpAddress,
voicePortIfDnsDomain DisplayString,
voicePortIfOperDnsDomain DisplayString
}
voicePortIfConfigModuleIndex OBJECT-TYPE
SYNTAX INTEGER (1..16)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An index value that uniquely identifies the
module where this port is located."
::= { voicePortIfConfigEntry 1 }
voicePortIfConfigPortIndex OBJECT-TYPE
SYNTAX INTEGER (1..255)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An index value that uniquely identifies this port
within a module. The value is determined by the
location of the port on the module."
::= { voicePortIfConfigEntry 2 }
voicePortIfDHCPEnabled OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Indicate whether DHCP service is enabled."
DEFVAL { true }
::= { voicePortIfConfigEntry 3 }
voicePortIfIpAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION "This port's IP address. This object
is configurable only if voicePortIfDHCPEnabled
is false. When the value of voicePortIfDHCPEnabled
is false, this object should be configured."
::= { voicePortIfConfigEntry 4 }
voicePortIfIpNetMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION "This port's subnet mask. This object
is configurable only if voicePortIfDHCPEnabled
is false. When the value of voicePortIfDHCPEnabled
is false, this object should be configured."
::= { voicePortIfConfigEntry 5 }
voicePortIfTftpServerAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION "This port's TFTP Server address. This object
is configurable only if voicePortIfDHCPEnabled
is false. When the value of voicePortIfDHCPEnabled
is false, this object should be configured."
::= { voicePortIfConfigEntry 6 }
voicePortIfGatewayAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION "This port's router address. This object
is configurable only if voicePortIfDHCPEnabled
is false."
::= { voicePortIfConfigEntry 7 }
voicePortIfDnsServerAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION "This port's DNS Server address. This object
is configurable only if voicePortIfDHCPEnabled
is false."
::= { voicePortIfConfigEntry 8 }
voicePortIfDnsDomain OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "This port's DNS domain name. This object
is configurable only if voicePortIfDHCPEnabled
is false."
::= { voicePortIfConfigEntry 9 }
voicePortIfOperDnsDomain OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This port's operational DNS domain name. If
voicePortIfDHCPEnabled is true, this object
indicates the domain name taken from the
DHCP server. If voicePortIfDHCPEnabled is false,
this object indicates the domain name configured
by users for this voice port or the domain name
taken from DNS configuration for the system
otherwise."
::= { voicePortIfConfigEntry 10 }
-- Voice Port Call Manager Table
voicePortCallManagerTable OBJECT-TYPE
SYNTAX SEQUENCE OF VoicePortCallManagerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A list of call manager entries. The number of
entries is determined by the number of modules in
the chassis and the number of ports with the
voice port interface configuration capability
in the system."
::= { voiceGrp 2 }
voicePortCallManagerEntry OBJECT-TYPE
SYNTAX VoicePortCallManagerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Entry containing voice interface configuration
for a particular port."
INDEX { voicePortModuleIndex, voicePortIndex,
voicePortCallManagerIndex }
::= { voicePortCallManagerTable 1 }
VoicePortCallManagerEntry ::=
SEQUENCE {
voicePortModuleIndex
INTEGER,
voicePortIndex
INTEGER,
voicePortCallManagerIndex
INTEGER,
voicePortCallManagerIpAddr
IpAddress
}
voicePortModuleIndex OBJECT-TYPE
SYNTAX INTEGER(1..16)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An index value that uniquely identifies the
module where this port is located."
::= { voicePortCallManagerEntry 1 }
voicePortIndex OBJECT-TYPE
SYNTAX INTEGER (1..255)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An index value that uniquely identifies this port
within a module."
::= { voicePortCallManagerEntry 2 }
voicePortCallManagerIndex OBJECT-TYPE
SYNTAX INTEGER (1..5)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An index value that uniquely identifies this
CallManager within a module/port. A port can
register up to 5 CallManager."
::= { voicePortCallManagerEntry 3 }
voicePortCallManagerIpAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The Call Manager IP Address of this port. A port
can register up to 5 call managers."
::= { voicePortCallManagerEntry 4 }
-- Voice Port Operational Dns Server Table
voicePortOperDnsServerTable OBJECT-TYPE
SYNTAX SEQUENCE OF VoicePortOperDnsServerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A list of operational DNS entries used by the
voice ports."
::= { voiceGrp 3 }
voicePortOperDnsServerEntry OBJECT-TYPE
SYNTAX VoicePortOperDnsServerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Entry containing infomation on DNS servers may be
used for a particular voice port.
If DHCP is enabled on a port, the DNS server IP
address will come from the DHCP server. If DHCP
is disabled, the DNS server IP address can be
configured by users through the mib object
voicePortIfDnsServerAddress for a port, otherwise
it will be taken from DNS configuration in the
system."
INDEX { voicePortDnsModuleIndex, voicePortDnsPortIndex,
voicePortOperDnsServerIndex }
::= { voicePortOperDnsServerTable 1 }
VoicePortOperDnsServerEntry ::=
SEQUENCE {
voicePortDnsModuleIndex
INTEGER,
voicePortDnsPortIndex
INTEGER,
voicePortOperDnsServerIndex
Unsigned32,
voicePortOperDnsServerIpAddr
IpAddress,
voicePortOperDnsServerSource
INTEGER
}
voicePortDnsModuleIndex OBJECT-TYPE
SYNTAX INTEGER(1..16)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An index value that uniquely identifies the
module where this port is located."
::= { voicePortOperDnsServerEntry 1 }
voicePortDnsPortIndex OBJECT-TYPE
SYNTAX INTEGER (1..255)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An index value that uniquely identifies this port
within a module."
::= { voicePortOperDnsServerEntry 2 }
voicePortOperDnsServerIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An index value that uniquely identifies this DNS
server within a module/port. This value indicates
the priority order among these DNS servers."
::= { voicePortOperDnsServerEntry 3 }
voicePortOperDnsServerIpAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The operational DNS Server IP Address of this
port. "
::= { voicePortOperDnsServerEntry 4 }
voicePortOperDnsServerSource OBJECT-TYPE
SYNTAX INTEGER {
fromDhcp (1),
fromPortConfig (2),
fromSystemConfig (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The source of the Dns Server IP Address of this
port.
fromDhcp(1) indicates that the DNS server IP
address comes from the DHCP server.
fromPortConfig(2) indicates that the DNS server IP
address comes from the object
voicePorfIfDnsServerAdress.
fromSystemConfig(3) indicates that the DNS server
IP address comes from DNS configuration for the
system."
::= { voicePortOperDnsServerEntry 5 }
-- the port jumbo frame group
-- If the port jumbo frame feature is supported, this
-- portJumboFrameTable
-- should be implemented.
portJumboFrameTable OBJECT-TYPE
SYNTAX SEQUENCE OF PortJumboFrameEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A list of port jumbo frame entries. The number of
entries is determined by the number of ports in
the system which support the Jumbo frame feature."
::= { portJumboFrameGrp 1}
portJumboFrameEntry OBJECT-TYPE
SYNTAX PortJumboFrameEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Entry containing the jumbo frame configuration
for a particular port."
INDEX { portJumboFrameModuleIndex,
portJumboFramePortIndex }
::= { portJumboFrameTable 1 }
PortJumboFrameEntry ::=
SEQUENCE {
portJumboFrameModuleIndex
INTEGER,
portJumboFramePortIndex
INTEGER,
portJumboFrameEnable
INTEGER
}
portJumboFrameModuleIndex OBJECT-TYPE
SYNTAX INTEGER (1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "An index value that uniquely identifies the
module where this port is located."
::= { portJumboFrameEntry 1 }
portJumboFramePortIndex OBJECT-TYPE
SYNTAX INTEGER (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "An index value that uniquely identifies this port
within a module. The value is determined by the
location of the port on the module. Valid entries
are 1 to the value of moduleNumPorts for this
module."
::= { portJumboFrameEntry 2 }
portJumboFrameEnable OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Indicates the jumbo frame status of the port. If
enabled, the port supports frame size greater than
the standard ethernet frame size of 1518 bytes."
::= { portJumboFrameEntry 3 }
-- the switch acceleration group
-- If the module switch acceleration feature is supported, the
-- switchAccelerationModuleTable should be implemented.
switchAccelerationModuleTable OBJECT-TYPE
SYNTAX SEQUENCE OF SwitchAccelerationModuleEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table contains a list of the modules for
which the switch acceleration capability can be
configured."
::= { switchAccelerationGrp 1 }
switchAccelerationModuleEntry OBJECT-TYPE
SYNTAX SwitchAccelerationModuleEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A module for which switch acceleration can be
configured."
INDEX { switchAccelerationModuleIndex }
::= { switchAccelerationModuleTable 1 }
SwitchAccelerationModuleEntry ::=
SEQUENCE {
switchAccelerationModuleIndex
INTEGER,
switchAccelerationModuleEnable
TruthValue
}
switchAccelerationModuleIndex OBJECT-TYPE
SYNTAX INTEGER (1..16)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The value of moduleIndex for the module where
switch acceleration feature can be configured."
::= {switchAccelerationModuleEntry 1 }
switchAccelerationModuleEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Indicates whether switch acceleration is enabled
on this module or not.
When this feature is enabled, the system will
increase the switching bandwidth, but the
ifAdminStatus of any port on this module can not
be set to 'up'.
If the ifAdminStatus of any port on this module is
'up', this feature can not be enabled until
ifAdminStatus of all ports on the module is set
to 'down'."
DEFVAL { false }
::= {switchAccelerationModuleEntry 2 }
-- The configuration Group
configMode OBJECT-TYPE
SYNTAX INTEGER {
binary(1), -- binary mode
text(2) -- text mode
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Configuration mode to store the configuration
information."
DEFVAL { binary }
::= { configGrp 1 }
configTextFileLocation OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The location of the text configuration file
which can be either NVRAM or a file in the
FLASH file system. If the location is NVRAM,
this object is a zero length octet string.
Otherwise, the FLASH file should be specified
in <device>:<filename> format. This object
is only instantiated when configMode has
the value of of text(2). "
DEFVAL {''H }
::= { configGrp 2 }
configWriteMem OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "When this object is set to true(1), the current
configuration is saved in text format in the
location specified by configTextFileLocation.
This object is only instantiated when configMode
has the value of text(2). When read,
this object always returns false(2). "
::= { configGrp 3 }
configWriteMemStatus OBJECT-TYPE
SYNTAX INTEGER {
inProgress(1),
succeeded(2),
resourceUnavailable(3),
badFileName(4),
someOtherError(5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The status of the current or the most recently
completed 'write memory' operation. The possible
values are:
inProgress - 'write' operation in progress;
succeeded - the 'write' was successful (this
value is also used when no write has been
invoked since the last time the local system
restarted);
resourceUnavailable, -the 'write' failed because
insufficeient resource was available.
badFileName - the 'write' failed because the
specified destination file was not found.
This might be due to invalid FLASH device
name or invalid file name.
someOtherError - the 'write' failed for some
other reason.
This object is only instantiated when configMode
has the value of text(2). "
::= { configGrp 4 }
-- traps
ciscoStackNotificationsPrefix OBJECT IDENTIFIER ::= { workgroup 0 }
lerAlarmOn NOTIFICATION-TYPE
OBJECTS { fddimibPORTSMTIndex, fddimibPORTIndex }
STATUS current
DESCRIPTION "A lerAlarmOn trap signifies that the agent entity
has detected that the fddimibPORTLerFlag object in
the FDDI-SMT73-MIB (RFC 1512) has transitioned to
the true(1) state for one of its ports.
The generation of this trap can be controlled by
the fddimibPORTLerAlarm object in the
FDDI-SMT73-MIB for each port."
::= { ciscoStackNotificationsPrefix 1}
lerAlarmOff NOTIFICATION-TYPE
OBJECTS { fddimibPORTSMTIndex, fddimibPORTIndex }
STATUS current
DESCRIPTION "A lerAlarmOff trap signifies that the agent
entity has detected that the fddimibPORTLerFlag
object in the FDDI-SMT73-MIB (RFC 1512) has
transitioned to the false(2) state for one of
its ports. The generation of this trap can be
controlled by the fddimibPORTLerAlarm object in
the FDDI-SMT73-MIB for each port."
::= { ciscoStackNotificationsPrefix 2}
moduleUp NOTIFICATION-TYPE
OBJECTS { moduleIndex, moduleType }
STATUS current
DESCRIPTION "A moduleUp trap signifies that the agent entity
has detected that the moduleStatus object in this
MIB has transitioned to the ok(2) state for one of
its modules.
The generation of this trap can be controlled by
the sysEnableModuleTraps object in this MIB."
::= { ciscoStackNotificationsPrefix 3}
moduleDown NOTIFICATION-TYPE
OBJECTS { moduleIndex, moduleType }
STATUS current
DESCRIPTION "A moduleDown trap signifies that the agent entity
has detected that the moduleStatus object in this
MIB has transitioned out of the ok(2) state for
one of its modules.
The generation of this trap can be controlled by
the sysEnableModuleTraps object in this MIB."
::= { ciscoStackNotificationsPrefix 4}
chassisAlarmOn NOTIFICATION-TYPE
OBJECTS { chassisTempAlarm, chassisMinorAlarm,
chassisMajorAlarm }
STATUS current
DESCRIPTION "A chassisAlarmOn trap signifies that the agent
entity has detected the chassisTempAlarm,
chassisMinorAlarm, or chassisMajorAlarm object in
this MIB has transitioned to the on(2) state.
The generation of this trap can be controlled by
the sysEnableChassisTraps object in this MIB."
::= { ciscoStackNotificationsPrefix 5}
chassisAlarmOff NOTIFICATION-TYPE
OBJECTS { chassisTempAlarm, chassisMinorAlarm,
chassisMajorAlarm }
STATUS current
DESCRIPTION "A chassisAlarmOff trap signifies that the agent
entity has detected the chassisTempAlarm,
chassisMinorAlarm, or chassisMajorAlarm object in
this MIB has transitioned to the off(1) state.
The generation of this trap can be controlled by
the sysEnableChassisTraps object in this MIB."
::= { ciscoStackNotificationsPrefix 6}
ipPermitDeniedTrap NOTIFICATION-TYPE
OBJECTS { ipPermitDeniedAddress, ipPermitDeniedAccess }
STATUS current
DESCRIPTION "ipPermitDeniedTrap indicates that IP permit
denied access happens. The generation of this
trap can be controlled by the
sysEnableIpPermitTraps object in this MIB."
::= { ciscoStackNotificationsPrefix 7}
sysConfigChangeTrap NOTIFICATION-TYPE
OBJECTS { sysConfigChangeTime, sysConfigChangeInfo }
STATUS current
DESCRIPTION "A sysConfigChange trap signifies that the system
configuration in NVRAM is changed. The generation
of this trap can be controlled by the
sysEnableConfigTraps object in this MIB."
::= { ciscoStackNotificationsPrefix 9 }
tokenRingSoftErrExceededTrap NOTIFICATION-TYPE
OBJECTS { ringStationMacAddress, ifIndex, ifName }
STATUS current
DESCRIPTION "This trap is generated when a station local to a
token ring port exceeds its Soft Error Threshold
within the configured interval."
::= { ciscoStackNotificationsPrefix 10 }
-- conformance information
ciscoStackMIBConformance OBJECT IDENTIFIER ::= { ciscoStackMIB 31 }
ciscoStackMIBCompliances OBJECT IDENTIFIER ::=
{ ciscoStackMIBConformance 1 }
ciscoStackMIBGroups OBJECT IDENTIFIER ::=
{ ciscoStackMIBConformance 2 }
-- compliance statements
ciscoStackgMIBCompliance MODULE-COMPLIANCE
STATUS deprecated
DESCRIPTION "The compliance statement for entities which
implement the Cisco stack MIB."
MODULE -- this module
MANDATORY-GROUPS {
systemMiscGroup,
systemTrapGroup,
chassisGroup,
moduleGroup,
portGroup
}
GROUP optionalSystemMiscGroup
DESCRIPTION "The OptionalSystemMiscGroup is an optional group
containing objects providing information about
the miscellaneous system features."
GROUP optionalSystemTrapGroup
DESCRIPTION "The OptionalSystemTrapGroup is an optional group
containing objects providing information about
the SNMP traps feature."
GROUP optionalChassisGroup
DESCRIPTION "The OptionalChassisGroup is an optional group
containing objects providing information about the
chassis of the device."
GROUP optionalModuleGroup
DESCRIPTION "The OptionalMooduleGroup is an optional group
containing objects providing information about the
modules on the device."
GROUP optionalPortGroup
DESCRIPTION "The OptionalPortGroup is an optional group
containing objects providing information about the
ports on the device."
GROUP systemTrafficGroup
DESCRIPTION "The systemTrafficGroup is an optional group
containing objects providing information about the
traffic meter feature."
GROUP systemFddiGroup
DESCRIPTION "The systemFddiGroup is an optional group
containing objects providing information about the
FDDI ring feature."
GROUP systemRmonGroup
DESCRIPTION "The systemRmonGroup is an optional group
containing objects providing information about the
extended RMON feature."
GROUP authenticationGroup
DESCRIPTION "The authenticationGroup is an optional group
containing objects providing information about
the authentication features."
GROUP tftpGroup
DESCRIPTION "The tftpGroup is an optional group containing
objects providing information about the tftp
upload/download features."
GROUP brouteEnableGroup
DESCRIPTION "The brouteEnableGroup is an optional group
containing objects providing information about the
combined bridging/routing feature."
GROUP filterGroup
DESCRIPTION "The filterGroup is an optional group containing
objects providing information about the port
filtering feature."
GROUP monitorGroup
DESCRIPTION "The monitorGroup is an optional group containing
objects providing information about the port
monitoring feature, also known as the Switched
Port ANalyzer (SPAN) feature."
GROUP vlanGroup
DESCRIPTION "The vlanGroup is an optional group containing
objects providing information about the Virtual
LAN features."
GROUP vmpsGroup
DESCRIPTION "The vmps is an optional group containing objects
providing information about the Vlan Membership
Policy Server feature."
GROUP tokenRingGroup
DESCRIPTION "The tokenRingGroup is an optional group
containing objects providing information about
the tokenring features."
GROUP mcastGroup
DESCRIPTION "The mcastGroup is an optional group containing
objects providing information about the multicast
features."
GROUP dnsGroup
DESCRIPTION "The dnsGroup is an optional group containing
objects providing information about the DNS
feature."
GROUP syslogGroup
DESCRIPTION "The syslogGroup is an optional group containing
objects providing information about the system log
feature."
GROUP ntpGroup
DESCRIPTION "The ntpGroup is an optional group containing
objects providing information about the network
time protocol feature."
GROUP ipPermitGroup
DESCRIPTION "The ipPermitGroup is an optional group containing
objects providing information about the ip permit
list feature."
GROUP mdgGatewayGroup
DESCRIPTION "The mdgGatewayGroup is an optional group
containing objects providing information about
the multiple default gateway feature."
GROUP traceRouteGroup
DESCRIPTION "The traceRouteGroup is an optional group
containing objects providing information about
the trace route feature."
GROUP ntpAuthenticationGroup
DESCRIPTION "The ntpAuthenticationGroup is an optional group
containing objects providing information about the
network time protocol authentication feature."
GROUP tokenRingSoftErrorMonitorGroup
DESCRIPTION "The tokenRingSoftErrorMonitorGroup is an optional
group containing objects providing information
about the token ring port soft error monitoring
feature."
GROUP portCpbGroup1
DESCRIPTION "The portCpbGroup1 is an optional group containing
objects providing additional information about the
port capabilities on the device."
GROUP portSecurityGroup1
DESCRIPTION "The portSecurityGroup1 is an optional group
containing objects providing additional
information for supporting port security feature
with the multiple secured source MAC addresses."
GROUP fileCopyGroup
DESCRIPTION "The fileCopyGroup is an optional group containing
objects providing information about the tftp/rcp
or local file upload/download features."
GROUP optionalSystemMiscGroup1
DESCRIPTION "The optionalSystemMiscGroup1 is an optional group
containing objects providing information about the
miscellaneous system features."
::= { ciscoStackMIBCompliances 1 }
ciscoStackgMIBCompliance2 MODULE-COMPLIANCE
STATUS deprecated
DESCRIPTION "The compliance statement for entities which
implement the Cisco stack MIB."
MODULE -- this module
MANDATORY-GROUPS {
systemMiscGroup,
systemTrapGroup,
chassisGroup,
moduleGroup,
portGroup
}
GROUP optionalSystemMiscGroup
DESCRIPTION "The OptionalSystemMiscGroup is an optional group
containing objects providing information about
the miscellaneous system features."
GROUP optionalSystemTrapGroup
DESCRIPTION "The OptionalSystemTrapGroup is an optional group
containing objects providing information about the
SNMP traps feature."
GROUP optionalChassisGroup
DESCRIPTION "The OptionalChassisGroup is an optional group
containing objects providing information about the
chassis of the device."
GROUP optionalModuleGroup
DESCRIPTION "The OptionalMooduleGroup is an optional group
containing objects providing information about the
modules on the device."
GROUP optionalPortGroup
DESCRIPTION "The OptionalPortGroup is an optional group
containing objects providing information about the
ports on the device."
GROUP systemTrafficGroup
DESCRIPTION "The systemTrafficGroup is an optional group
containing objects providing information about the
traffic meter feature."
GROUP systemFddiGroup
DESCRIPTION "The systemFddiGroup is an optional group
containing objects providing information about the
FDDI ring feature."
GROUP systemRmonGroup
DESCRIPTION "The systemRmonGroup is an optional group
containing objects providing information about
the extended RMON feature."
GROUP authenticationGroup
DESCRIPTION "The authenticationGroup is an optional group
containing objects providing information about
the authentication features."
GROUP tftpGroup
DESCRIPTION "The tftpGroup is an optional group containing
objects providing information about the tftp
upload/download features."
GROUP brouteEnableGroup
DESCRIPTION "The brouteEnableGroup is an optional group
containing objects providing information about
the combined bridging/routing feature."
GROUP filterGroup
DESCRIPTION "The filterGroup is an optional group containing
objects providing information about the port
filtering feature."
GROUP monitorGroup
DESCRIPTION "The monitorGroup is an optional group containing
objects providing information about the port
monitoring feature, also known as the Switched
Port ANalyzer (SPAN) feature."
GROUP vlanGroup
DESCRIPTION "The vlanGroup is an optional group containing
objects providing information about the Virtual
LAN features."
GROUP vmpsGroup
DESCRIPTION "The vmps is an optional group containing objects
providing information about the Vlan Membership
Policy Server feature."
GROUP tokenRingGroup
DESCRIPTION "The tokenRingGroup is an optional group
containing objects providing information about
the tokenring features."
GROUP mcastGroup
DESCRIPTION "The mcastGroup is an optional group containing
objects providing information about the multicast
features."
GROUP dnsGroup
DESCRIPTION "The dnsGroup is an optional group containing
objects providing information about the DNS
feature."
GROUP syslogGroup
DESCRIPTION "The syslogGroup is an optional group containing
objects providing information about the system log
feature."
GROUP ntpGroup
DESCRIPTION "The ntpGroup is an optional group containing
objects providing information about the network
time protocol feature."
GROUP ipPermitGroup
DESCRIPTION "The ipPermitGroup is an optional group containing
objects providing information about the ip permit
list feature."
GROUP mdgGatewayGroup
DESCRIPTION "The mdgGatewayGroup is an optional group
containing objects providing information about
the multiple default gateway feature."
GROUP traceRouteGroup
DESCRIPTION "The traceRouteGroup is an optional group
containing objects providing information about
the trace route feature."
GROUP ntpAuthenticationGroup
DESCRIPTION "The ntpAuthenticationGroup is an optional group
containing objects providing information about the
network time protocol authentication feature."
GROUP tokenRingSoftErrorMonitorGroup
DESCRIPTION "The tokenRingSoftErrorMonitorGroup is an optional
group containing objects providing information
about the token ring port soft error monitoring
feature."
GROUP portCpbGroup1
DESCRIPTION "The portCpbGroup1 is an optional group containing
objects providing additional information about the
port capabilities on the device."
GROUP portSecurityGroup1
DESCRIPTION "The portSecurityGroup1 is an optional group
containing objects providing additional
information for supporting port security feature
with the multiple secured source MAC addresses."
GROUP fileCopyGroup
DESCRIPTION "The fileCopyGroup is an optional group containing
objects providing information about the tftp/rcp
or local file upload/download features."
GROUP optionalSystemMiscGroup1
DESCRIPTION "The optionalSystemMiscGroup1 is an optional group
containing objects providing information about the
miscellaneous system features."
GROUP ipPermitGroup1
DESCRIPTION "The ipPermitGroup1 is an optional group
containing objects providing information about
the ip permit list feature."
GROUP optionalSystemMiscGroup2
DESCRIPTION "The optionalSystemMiscGroup2 is an optional group
containing objects providing information about the
miscellaneous system features."
GROUP filterGroup1
DESCRIPTION "The filterGroup is an optional group containing
objects providing information about the port
filtering feature."
GROUP mcastGroup1
DESCRIPTION "The mcastGroup1 is an optional group containing
objects providing information about the
multicast features."
GROUP portGroup1
DESCRIPTION "The portGroup1 is an optional group containing
objects providing information about the ports on
the device."
GROUP chassisGroup1
DESCRIPTION "The chassisGroup1 is a group containing objects
providing information about the chassis of the
device. This group must be implemented by systems
that can have 3 or more power supplies."
GROUP moduleGroup1
DESCRIPTION "The moduleGroup1 is an optional group containing
objects providing information about the modules
on the device."
GROUP portCpbGroup2
DESCRIPTION "The portCpbGroup2 is an optional group containing
objects providing additional information about the
port capabilities on the device."
::= { ciscoStackMIBCompliances 2 }
ciscoStackgMIBCompliance3 MODULE-COMPLIANCE
STATUS deprecated
DESCRIPTION "The compliance statement for entities which
implement the Cisco stack MIB."
MODULE -- this module
MANDATORY-GROUPS {
systemMiscGroup,
systemTrapGroup,
chassisGroup,
moduleGroup,
portGroup
}
GROUP optionalSystemMiscGroup
DESCRIPTION "The OptionalSystemMiscGroup is an optional group
containing objects providing information about
the miscellaneous system features."
GROUP optionalSystemTrapGroup
DESCRIPTION "The OptionalSystemTrapGroup is an optional group
containing objects providing information about the
SNMP traps feature."
GROUP optionalChassisGroup
DESCRIPTION "The OptionalChassisGroup is an optional group
containing objects providing information about the
chassis of the device."
GROUP optionalModuleGroup
DESCRIPTION "The OptionalMooduleGroup is an optional group
containing objects providing information about the
modules on the device."
GROUP optionalPortGroup
DESCRIPTION "The OptionalPortGroup is an optional group
containing objects providing information about the
ports on the device."
GROUP systemTrafficGroup
DESCRIPTION "The systemTrafficGroup is an optional group
containing objects providing information about
the traffic meter feature."
GROUP systemFddiGroup
DESCRIPTION "The systemFddiGroup is an optional group
containing objects providing information about
the FDDI ring feature."
GROUP systemRmonGroup
DESCRIPTION "The systemRmonGroup is an optional group
containing objects providing information about the
extended RMON feature."
GROUP authenticationGroup
DESCRIPTION "The authenticationGroup is an optional group
containing objects providing information about the
authentication features."
GROUP tftpGroup
DESCRIPTION "The tftpGroup is an optional group containing
objects providing information about the tftp
upload/download features."
GROUP brouteEnableGroup
DESCRIPTION "The brouteEnableGroup is an optional group
containing objects providing information about the
combined bridging/routing feature."
GROUP filterGroup
DESCRIPTION "The filterGroup is an optional group containing
objects providing information about the port
filtering feature."
GROUP monitorGroup
DESCRIPTION "The monitorGroup is an optional group containing
objects providing information about the port
monitoring feature, also known as the Switched
Port ANalyzer (SPAN) feature."
GROUP vlanGroup
DESCRIPTION "The vlanGroup is an optional group containing
objects providing information about the Virtual
LAN features."
GROUP vmpsGroup
DESCRIPTION "The vmps is an optional group containing objects
providing information about the Vlan Membership
Policy Server feature."
GROUP tokenRingGroup
DESCRIPTION "The tokenRingGroup is an optional group
containing objects providing information about
the tokenring features."
GROUP mcastGroup
DESCRIPTION "The mcastGroup is an optional group containing
objects providing information about the multicast
features."
GROUP dnsGroup
DESCRIPTION "The dnsGroup is an optional group containing
objects providing information about the DNS
feature."
GROUP syslogGroup
DESCRIPTION "The syslogGroup is an optional group containing
objects providing information about the system log
feature."
GROUP ntpGroup
DESCRIPTION "The ntpGroup is an optional group containing
objects providing information about the network
time protocol feature."
GROUP ipPermitGroup
DESCRIPTION "The ipPermitGroup is an optional group containing
objects providing information about the ip permit
list feature."
GROUP mdgGatewayGroup
DESCRIPTION "The mdgGatewayGroup is an optional group
containing objects providing information about
the multiple default gateway feature."
GROUP traceRouteGroup
DESCRIPTION "The traceRouteGroup is an optional group
containing objects providing information about
the trace route feature."
GROUP ntpAuthenticationGroup
DESCRIPTION "The ntpAuthenticationGroup is an optional group
containing objects providing information about the
network time protocol authentication feature."
GROUP tokenRingSoftErrorMonitorGroup
DESCRIPTION "The tokenRingSoftErrorMonitorGroup is an optional
group containing objects providing information
about the token ring port soft error monitoring
feature."
GROUP portCpbGroup1
DESCRIPTION "The portCpbGroup1 is an optional group containing
objects providing additional information about the
port capabilities on the device."
GROUP portSecurityGroup1
DESCRIPTION "The portSecurityGroup1 is an optional group
containing objects providing additional
information for supporting port security feature
with the multiple secured source MAC addresses."
GROUP fileCopyGroup
DESCRIPTION "The fileCopyGroup is an optional group containing
objects providing information about the tftp/rcp
or local file upload/download features."
GROUP optionalSystemMiscGroup1
DESCRIPTION "The optionalSystemMiscGroup1 is an optional group
containing objects providing information about the
miscellaneous system features."
GROUP ipPermitGroup1
DESCRIPTION "The ipPermitGroup1 is an optional group
containing objects providing information about
the ip permit list feature."
GROUP optionalSystemMiscGroup2
DESCRIPTION "The optionalSystemMiscGroup2 is an optional group
containing objects providing information about the
miscellaneous system features."
GROUP filterGroup1
DESCRIPTION "The filterGroup is an optional group containing
objects providing information about the port
filtering feature."
GROUP mcastGroup1
DESCRIPTION "The mcastGroup1 is an optional group containing
objects providing information about the
multicast features."
GROUP portGroup1
DESCRIPTION "The portGroup1 is an optional group containing
objects providing information about the ports on
the device."
GROUP chassisGroup1
DESCRIPTION "The chassisGroup1 is a group containing objects
providing information about the chassis of the
device. This group must be implemented by systems
that can have 3 or more power supplies."
GROUP moduleGroup1
DESCRIPTION "The moduleGroup1 is an optional group containing
objects providing information about the modules
on the device."
GROUP portCpbGroup2
DESCRIPTION "The portCpbGroup2 is an optional group containing
objects providing additional information about the
port capabilities on the device."
GROUP voiceGroup
DESCRIPTION "The voiceGroup is an optional group containing
objects providing information about the voice port
on the device."
GROUP moduleGroup2
DESCRIPTION "The moduleGroup2 is an mandatory group
containing objects providing information about
the modules on the device."
GROUP portCpbGroup3
DESCRIPTION "The portCpbGroup3 is an optional group containing
objects providing additional information about the
port capabilities on the device."
GROUP vlanGroup1
DESCRIPTION "The vlanGroup1 is an optional group containing
objects providing information about the Virtual
LAN features."
GROUP portGroup2
DESCRIPTION "The portGroup2 is an optional group containing
objects providing information about the ports on
the device."
GROUP switchAccelerationModuleGroup
DESCRIPTION "This group is mandatory for implementations of
switch acceleration capability."
GROUP optionalSystemMiscGroup3
DESCRIPTION "The optionalSystemMiscGroup3 is an optional group
containing objects providing information about the
miscellaneous system features."
::= { ciscoStackMIBCompliances 3 }
ciscoStackgMIBCompliance4 MODULE-COMPLIANCE
STATUS deprecated
DESCRIPTION "The compliance statement for entities which
implement the Cisco stack MIB."
MODULE -- this module
MANDATORY-GROUPS {
systemMiscGroup,
systemTrapGroup,
chassisGroup,
moduleGroup,
portGroup
}
GROUP optionalSystemMiscGroup
DESCRIPTION "The OptionalSystemMiscGroup is an optional group
containing objects providing information about
the miscellaneous system features."
GROUP optionalSystemTrapGroup
DESCRIPTION "The OptionalSystemTrapGroup is an optional group
containing objects providing information about the
SNMP traps feature."
GROUP optionalChassisGroup
DESCRIPTION "The OptionalChassisGroup is an optional group
containing objects providing information about the
chassis of the device."
GROUP optionalModuleGroup
DESCRIPTION "The OptionalMooduleGroup is an optional group
containing objects providing information about the
modules on the device."
GROUP optionalPortGroup
DESCRIPTION "The OptionalPortGroup is an optional group
containing objects providing information about the
ports on the device."
GROUP systemTrafficGroup
DESCRIPTION "The systemTrafficGroup is an optional group
containing objects providing information about the
traffic meter feature."
GROUP systemFddiGroup
DESCRIPTION "The systemFddiGroup is an optional group
containing objects providing information about the
FDDI ring feature."
GROUP systemRmonGroup
DESCRIPTION "The systemRmonGroup is an optional group
containing objects providing information about the
extended RMON feature."
GROUP authenticationGroup
DESCRIPTION "The authenticationGroup is an optional group
containing objects providing information about the
authentication features."
GROUP tftpGroup
DESCRIPTION "The tftpGroup is an optional group containing
objects providing information about the tftp
upload/download features."
GROUP brouteEnableGroup
DESCRIPTION "The brouteEnableGroup is an optional group
containing objects providing information about the
combined bridging/routing feature."
GROUP filterGroup
DESCRIPTION "The filterGroup is an optional group containing
objects providing information about the port
filtering feature."
GROUP monitorGroup
DESCRIPTION "The monitorGroup is an optional group containing
objects providing information about the port
monitoring feature, also known as the Switched
Port ANalyzer (SPAN) feature."
GROUP vlanGroup
DESCRIPTION "The vlanGroup is an optional group containing
objects providing information about the Virtual
LAN features."
GROUP vmpsGroup
DESCRIPTION "The vmps is an optional group containing objects
providing information about the Vlan Membership
Policy Server feature."
GROUP tokenRingGroup
DESCRIPTION "The tokenRingGroup is an optional group
containing objects providing information about
the tokenring features."
GROUP mcastGroup
DESCRIPTION "The mcastGroup is an optional group containing
objects providing information about the multicast
features."
GROUP dnsGroup
DESCRIPTION "The dnsGroup is an optional group containing
objects providing information about the DNS
feature."
GROUP syslogGroup
DESCRIPTION "The syslogGroup is an optional group containing
objects providing information about the system log
feature."
GROUP ntpGroup
DESCRIPTION "The ntpGroup is an optional group containing
objects providing information about the network
time protocol feature."
GROUP ipPermitGroup
DESCRIPTION "The ipPermitGroup is an optional group
containing objects providing information about
the ip permit list feature."
GROUP mdgGatewayGroup
DESCRIPTION "The mdgGatewayGroup is an optional group
containing objects providing information about
the multiple default gateway feature."
GROUP traceRouteGroup
DESCRIPTION "The traceRouteGroup is an optional group
containing objects providing information about
the trace route feature."
GROUP ntpAuthenticationGroup
DESCRIPTION "The ntpAuthenticationGroup is an optional group
containing objects providing information about the
network time protocol authentication feature."
GROUP tokenRingSoftErrorMonitorGroup
DESCRIPTION "The tokenRingSoftErrorMonitorGroup is an optional
group containing objects providing information
about the token ring port soft error monitoring
feature."
GROUP portCpbGroup1
DESCRIPTION "The portCpbGroup1 is an optional group containing
objects providing additional information about the
port capabilities on the device."
GROUP portSecurityGroup1
DESCRIPTION "The portSecurityGroup1 is an optional group
containing objects providing additional
information for supporting port security feature
with the multiple secured source MAC addresses."
GROUP fileCopyGroup
DESCRIPTION "The fileCopyGroup is an optional group containing
objects providing information about the tftp/rcp
or local file upload/download features."
GROUP optionalSystemMiscGroup1
DESCRIPTION "The optionalSystemMiscGroup1 is an optional group
containing objects providing information about the
miscellaneous system features."
GROUP ipPermitGroup1
DESCRIPTION "The ipPermitGroup1 is an optional group
containing objects providing information about
the ip permit list feature."
GROUP optionalSystemMiscGroup2
DESCRIPTION "The optionalSystemMiscGroup2 is an optional group
containing objects providing information about the
miscellaneous system features."
GROUP filterGroup1
DESCRIPTION "The filterGroup is an optional group containing
objects providing information about the port
filtering feature."
GROUP mcastGroup1
DESCRIPTION "The mcastGroup1 is an optional group containing
objects providing information about the
multicast features."
GROUP portGroup1
DESCRIPTION "The portGroup1 is an optional group containing
objects providing information about the ports on
the device."
GROUP chassisGroup1
DESCRIPTION "The chassisGroup1 is a group containing objects
providing information about the chassis of the
device. This group must be implemented by systems
that can have 3 or more power supplies."
GROUP moduleGroup1
DESCRIPTION "The moduleGroup1 is an optional group containing
objects providing information about the modules
on the device."
GROUP portCpbGroup2
DESCRIPTION "The portCpbGroup2 is an optional group containing
objects providing additional information about the
port capabilities on the device."
GROUP voiceGroup
DESCRIPTION "The voiceGroup is an optional group containing
objects providing information about the voice port
on the device."
GROUP moduleGroup2
DESCRIPTION "The moduleGroup2 is an mandatory group containing
objects providing information about the modules
on the device."
GROUP portCpbGroup3
DESCRIPTION "The portCpbGroup3 is an optional group containing
objects providing additional information about the
port capabilities on the device."
GROUP vlanGroup1
DESCRIPTION "The vlanGroup1 is an optional group containing
objects providing information about the Virtual
LAN features."
GROUP portGroup2
DESCRIPTION "The portGroup2 is an optional group containing
objects providing information about the ports on
the device."
GROUP switchAccelerationModuleGroup
DESCRIPTION "This group is mandatory for implementations of
switch acceleration capability."
GROUP optionalSystemMiscGroup3
DESCRIPTION "The optionalSystemMiscGroup3 is an optional group
containing objects providing information about the
miscellaneous system features."
GROUP optionalSystemMiscGroup4
DESCRIPTION "This group is an optional group containing
objects providing information about the
miscellaneous system features."
GROUP vlanTrunkMappingGroup
DESCRIPTION "This group is mandatory for implementations of
trunk VLAN to VLAN association feature on the
device."
GROUP portJumboFrameGroup
DESCRIPTION "This group is mandatory for implementations of
port jumbo frame feature on the device."
GROUP portCpbGroup4
DESCRIPTION "The portCpbGroup4 is an optional group containing
objects providing additional information about the
port capabilities on the device."
::= { ciscoStackMIBCompliances 4 }
ciscoStackgMIBCompliance5 MODULE-COMPLIANCE
STATUS deprecated
DESCRIPTION "The compliance statement for entities which
implement the Cisco stack MIB."
MODULE -- this module
MANDATORY-GROUPS {
systemMiscGroup,
systemTrapGroup,
chassisGroup,
moduleGroup,
portGroup
}
GROUP optionalSystemMiscGroup
DESCRIPTION "The OptionalSystemMiscGroup is an optional group
containing objects providing information about
the miscellaneous system features."
GROUP optionalSystemTrapGroup
DESCRIPTION "The OptionalSystemTrapGroup is an optional group
containing objects providing information about the
SNMP traps feature."
GROUP optionalChassisGroup
DESCRIPTION "The OptionalChassisGroup is an optional group
containing objects providing information about the
chassis of the device."
GROUP optionalModuleGroup
DESCRIPTION "The OptionalMooduleGroup is an optional group
containing objects providing information about the
modules on the device."
GROUP optionalPortGroup
DESCRIPTION "The OptionalPortGroup is an optional group
containing objects providing information about the
ports on the device."
GROUP systemTrafficGroup
DESCRIPTION "The systemTrafficGroup is an optional group
containing objects providing information about the
traffic meter feature."
GROUP systemFddiGroup
DESCRIPTION "The systemFddiGroup is an optional group
containing objects providing information about the
FDDI ring feature."
GROUP systemRmonGroup
DESCRIPTION "The systemRmonGroup is an optional group
containing objects providing information about the
extended RMON feature."
GROUP tftpGroup
DESCRIPTION "The tftpGroup is an optional group containing
objects providing information about the tftp
upload/download features."
GROUP brouteEnableGroup
DESCRIPTION "The brouteEnableGroup is an optional group
containing objects providing information about the
combined bridging/routing feature."
GROUP filterGroup
DESCRIPTION "The filterGroup is an optional group containing
objects providing information about the port
filtering feature."
GROUP vlanGroup
DESCRIPTION "The vlanGroup is an optional group containing
objects providing information about the Virtual
LAN features."
GROUP vmpsGroup
DESCRIPTION "The vmps is an optional group containing objects
providing information about the Vlan Membership
Policy Server feature."
GROUP tokenRingGroup
DESCRIPTION "The tokenRingGroup is an optional group
containing objects providing information about
the tokenring features."
GROUP mcastGroup
DESCRIPTION "The mcastGroup is an optional group containing
objects providing information about the multicast
features."
GROUP dnsGroup
DESCRIPTION "The dnsGroup is an optional group containing
objects providing information about the DNS
feature."
GROUP syslogGroup
DESCRIPTION "The syslogGroup is an optional group containing
objects providing information about the system log
feature."
GROUP ntpGroup
DESCRIPTION "The ntpGroup is an optional group containing
objects providing information about the network
time protocol feature."
GROUP ipPermitGroup
DESCRIPTION "The ipPermitGroup is an optional group containing
objects providing information about the ip permit
list feature."
GROUP mdgGatewayGroup
DESCRIPTION "The mdgGatewayGroup is an optional group
containing objects providing information about
the multiple default gateway feature."
GROUP traceRouteGroup
DESCRIPTION "The traceRouteGroup is an optional group
containing objects providing information about
the trace route feature."
GROUP ntpAuthenticationGroup
DESCRIPTION "The ntpAuthenticationGroup is an optional group
containing objects providing information about the
network time protocol authentication feature."
GROUP tokenRingSoftErrorMonitorGroup
DESCRIPTION "The tokenRingSoftErrorMonitorGroup is an optional
group containing objects providing information
about the token ring port soft error monitoring
feature."
GROUP portCpbGroup1
DESCRIPTION "The portCpbGroup1 is an optional group containing
objects providing additional information about the
port capabilities on the device."
GROUP portSecurityGroup1
DESCRIPTION "The portSecurityGroup1 is an optional group
containing objects providing additional
information for supporting port security feature
with the multiple secured source MAC addresses."
GROUP fileCopyGroup
DESCRIPTION "The fileCopyGroup is an optional group containing
objects providing information about the tftp/rcp
or local file upload/download features."
GROUP optionalSystemMiscGroup1
DESCRIPTION "The optionalSystemMiscGroup1 is an optional group
containing objects providing information about the
miscellaneous system features."
GROUP ipPermitGroup1
DESCRIPTION "The ipPermitGroup1 is an optional group
containing objects providing information about
the ip permit list feature."
GROUP optionalSystemMiscGroup2
DESCRIPTION "The optionalSystemMiscGroup2 is an optional group
containing objects providing information about the
miscellaneous system features."
GROUP filterGroup1
DESCRIPTION "The filterGroup is an optional group containing
objects providing information about the port
filtering feature."
GROUP mcastGroup1
DESCRIPTION "The mcastGroup1 is an optional group containing
objects providing information about the
multicast features."
GROUP portGroup1
DESCRIPTION "The portGroup1 is an optional group containing
objects providing information about the ports on
the device."
GROUP chassisGroup1
DESCRIPTION "The chassisGroup1 is a group containing objects
providing information about the chassis of the
device. This group must be implemented by systems
that can have 3 or more power supplies."
GROUP moduleGroup1
DESCRIPTION "The moduleGroup1 is an optional group containing
objects providing information about the modules
on the device."
GROUP portCpbGroup2
DESCRIPTION "The portCpbGroup2 is an optional group containing
objects providing additional information about the
port capabilities on the device."
GROUP voiceGroup
DESCRIPTION "The voiceGroup is an optional group containing
objects providing information about the voice port
on the device."
GROUP moduleGroup2
DESCRIPTION "The moduleGroup2 is an mandatory group
containing objects providing information about
the modules on the device."
GROUP portCpbGroup3
DESCRIPTION "The portCpbGroup3 is an optional group containing
objects providing additional information about the
port capabilities on the device."
GROUP portGroup2
DESCRIPTION "The portGroup2 is an optional group containing
objects providing information about the ports on
the device."
GROUP switchAccelerationModuleGroup
DESCRIPTION "This group is mandatory for implementations of
switch acceleration capability."
GROUP optionalSystemMiscGroup3
DESCRIPTION "The optionalSystemMiscGroup3 is an optional group
containing objects providing information about the
miscellaneous system features."
GROUP optionalSystemMiscGroup4
DESCRIPTION "This group is an optional group containing
objects providing information about the
miscellaneous system features."
GROUP vlanTrunkMappingGroup
DESCRIPTION "This group is mandatory for implementations of
trunk VLAN to VLAN association feature on the
device."
GROUP portJumboFrameGroup
DESCRIPTION "This group is mandatory for implementations of
port jumbo frame feature on the device."
GROUP portCpbGroup4
DESCRIPTION "The portCpbGroup4 is an optional group containing
objects providing additional information about the
port capabilities on the device."
GROUP fileCopyGroup2
DESCRIPTION "The fileCopyGroup2 is an optional group
containing objects providing additional
information about tftp/rcp or local file
upload/download features."
GROUP systemRmonGroup2
DESCRIPTION "The systemRmonGroup2 is an optional group
containing objects providing information about
RMON max memory usage control."
GROUP filterGroup2
DESCRIPTION "The filterGroup2 is an optional group containing
objects providing information about the
unicast/multicast port filtering feature."
GROUP optionalSystemMiscGroup5
DESCRIPTION "The optionalSystemMiscGroup5 is an optional group
containing objects providing information about
miscellaneous system features."
GROUP syslogGroup2
DESCRIPTION "The syslogGroup2 is an optional group containing
objects providing information about whether the
syslog messages should be sent to telnet
sessions."
GROUP systemStatusGroup
DESCRIPTION "The systemStatusGroup is an optional group
containing objects providing information about
system LED status."
GROUP configurationGroup
DESCRIPTION "The configurationGroup is an optional group
containing objects providing information about
the configuration mode to store the configuration
information."
GROUP filterGroup3
DESCRIPTION "The filterGroup3 is an optional group containing
objects providing information about Broadcast
Suppression Violation for port filtering
feature."
GROUP portGroup3
DESCRIPTION "The portGroup3 is an optional group containing
objects providing information about additional
information about the ports on the device."
GROUP portCpbGroup5
DESCRIPTION "The portCpbGroup5 is an optional group containing
objects providing additional information about
the port capabilities on the device."
GROUP authenticationGroup1
DESCRIPTION "The authenticationGroup1 is an optional group
containing objects providing information about the
authentication features."
::= { ciscoStackMIBCompliances 5 }
ciscoStackgMIBCompliance6 MODULE-COMPLIANCE
STATUS deprecated
DESCRIPTION "The compliance statement for entities which
implement the Cisco stack MIB."
MODULE -- this module
MANDATORY-GROUPS {
systemMiscGroup1,
systemTrapGroup1,
chassisGroup,
moduleGroup,
portGroup4
}
GROUP optionalSystemMiscGroup
DESCRIPTION "The OptionalSystemMiscGroup is an optional group
containing objects providing information about
the miscellaneous system features."
GROUP optionalSystemTrapGroup
DESCRIPTION "The OptionalSystemTrapGroup is an optional group
containing objects providing information about the
SNMP traps feature."
GROUP optionalChassisGroup1
DESCRIPTION "The OptionalChassisGroup1 is an optional group
containing objects providing information about the
chassis of the device."
GROUP optionalModuleGroup
DESCRIPTION "The OptionalMooduleGroup is an optional group
containing objects providing information about the
modules on the device."
GROUP optionalPortGroup1
DESCRIPTION "The OptionalPortGroup1 is an optional group
containing objects providing information about the
ports on the device."
GROUP systemTrafficGroup
DESCRIPTION "The systemTrafficGroup is an optional group
containing objects providing information about the
traffic meter feature."
GROUP systemFddiGroup
DESCRIPTION "The systemFddiGroup is an optional group
containing objects providing information about the
FDDI ring feature."
GROUP systemRmonGroup
DESCRIPTION "The systemRmonGroup is an optional group
containing objects providing information about the
extended RMON feature."
GROUP tftpGroup
DESCRIPTION "The tftpGroup is an optional group containing
objects providing information about the tftp
upload/download features."
GROUP brouteEnableGroup
DESCRIPTION "The brouteEnableGroup is an optional group
containing objects providing information about the
combined bridging/routing feature."
GROUP filterGroup
DESCRIPTION "The filterGroup is an optional group containing
objects providing information about the port
filtering feature."
GROUP vlanGroup2
DESCRIPTION "The vlanGroup2 is an optional group containing
objects providing information about the Virtual
LAN features."
GROUP vmpsGroup
DESCRIPTION "The vmps is an optional group containing objects
providing information about the Vlan Membership
Policy Server feature."
GROUP tokenRingGroup
DESCRIPTION "The tokenRingGroup is an optional group
containing objects providing information about
the tokenring features."
GROUP mcastGroup
DESCRIPTION "The mcastGroup is an optional group containing
objects providing information about the multicast
features."
GROUP dnsGroup
DESCRIPTION "The dnsGroup is an optional group containing
objects providing information about the DNS
feature."
GROUP syslogGroup
DESCRIPTION "The syslogGroup is an optional group containing
objects providing information about the system log
feature."
GROUP ntpGroup
DESCRIPTION "The ntpGroup is an optional group containing
objects providing information about the network
time protocol feature."
GROUP ipPermitGroup2
DESCRIPTION "The ipPermitGroup2 is an optional group
containing objects providing information
about the ip permit list feature."
GROUP mdgGatewayGroup
DESCRIPTION "The mdgGatewayGroup is an optional group
containing objects providing information about
the multiple default gateway feature."
GROUP traceRouteGroup
DESCRIPTION "The traceRouteGroup is an optional group
containing objects providing information about
the trace route feature."
GROUP ntpAuthenticationGroup
DESCRIPTION "The ntpAuthenticationGroup is an optional group
containing objects providing information about the
network time protocol authentication feature."
GROUP tokenRingSoftErrorMonitorGroup
DESCRIPTION "The tokenRingSoftErrorMonitorGroup is an optional
group containing objects providing information
about the token ring port soft error monitoring
feature."
GROUP portCpbGroup1
DESCRIPTION "The portCpbGroup1 is an optional group containing
objects providing additional information about the
port capabilities on the device."
GROUP portSecurityGroup1
DESCRIPTION "The portSecurityGroup1 is an optional group
containing objects providing additional
information for supporting port security feature
with the multiple secured source MAC addresses."
GROUP fileCopyGroup
DESCRIPTION "The fileCopyGroup is an optional group containing
objects providing information about the tftp/rcp
or local file upload/download features."
GROUP optionalSystemMiscGroup1
DESCRIPTION "The optionalSystemMiscGroup1 is an optional group
containing objects providing information about the
miscellaneous system features."
GROUP ipPermitGroup1
DESCRIPTION "The ipPermitGroup1 is an optional group
containing objects providing information about
the ip permit list feature."
GROUP optionalSystemMiscGroup6
DESCRIPTION "The optionalSystemMiscGroup6 is an optional group
containing objects providing information about the
miscellaneous system features."
GROUP filterGroup1
DESCRIPTION "The filterGroup1 is an optional group containing
objects providing information about the port
filtering feature."
GROUP mcastGroup1
DESCRIPTION "The mcastGroup1 is an optional group containing
objects providing information about the
multicast features."
GROUP portGroup1
DESCRIPTION "The portGroup1 is an optional group containing
objects providing information about the ports on
the device."
GROUP chassisGroup1
DESCRIPTION "The chassisGroup1 is a group containing objects
providing information about the chassis of the
device. This group must be implemented by systems
that can have 3 or more power supplies."
GROUP moduleGroup1
DESCRIPTION "The moduleGroup1 is an optional group containing
objects providing information about the modules
on the device."
GROUP portCpbGroup2
DESCRIPTION "The portCpbGroup2 is an optional group containing
objects providing additional information about the
port capabilities on the device."
GROUP voiceGroup
DESCRIPTION "The voiceGroup is an optional group containing
objects providing information about the voice port
on the device."
GROUP moduleGroup2
DESCRIPTION "The moduleGroup2 is an mandatory group
containing objects providing information about
the modules on the device."
GROUP portCpbGroup3
DESCRIPTION "The portCpbGroup3 is an optional group containing
objects providing additional information about the
port capabilities on the device."
GROUP portGroup2
DESCRIPTION "The portGroup2 is an optional group containing
objects providing information about the ports on
the device."
GROUP switchAccelerationModuleGroup
DESCRIPTION "This group is mandatory for implementations of
switch acceleration capability."
GROUP optionalSystemMiscGroup3
DESCRIPTION "The optionalSystemMiscGroup3 is an optional group
containing objects providing information about the
miscellaneous system features."
GROUP optionalSystemMiscGroup4
DESCRIPTION "This group is an optional group containing
objects providing information about the
miscellaneous system features."
GROUP vlanTrunkMappingGroup
DESCRIPTION "This group is mandatory for implementations of
trunk VLAN to VLAN association feature on the
device."
GROUP portJumboFrameGroup
DESCRIPTION "This group is mandatory for implementations of
port jumbo frame feature on the device."
GROUP portCpbGroup4
DESCRIPTION "The portCpbGroup4 is an optional group containing
objects providing additional information about the
port capabilities on the device."
GROUP fileCopyGroup2
DESCRIPTION "The fileCopyGroup2 is an optional group
containing objects providing additional
information about tftp/rcp or local file
upload/download features."
GROUP systemRmonGroup2
DESCRIPTION "The systemRmonGroup2 is an optional group
containing objects providing information about
RMON max memory usage control."
GROUP filterGroup2
DESCRIPTION "The filterGroup2 is an optional group containing
objects providing information about the
unicast/multicast port filtering feature."
GROUP optionalSystemMiscGroup5
DESCRIPTION "The optionalSystemMiscGroup5 is an optional group
containing objects providing information about
miscellaneous system features."
GROUP syslogGroup2
DESCRIPTION "The syslogGroup2 is an optional group containing
objects providing information about whether the
syslog messages should be sent to telnet
sessions."
GROUP systemStatusGroup
DESCRIPTION "The systemStatusGroup is an optional group
containing objects providing information about
system LED status."
GROUP configurationGroup
DESCRIPTION "The configurationGroup is an optional group
containing objects providing information about
the configuration mode to store the configuration
information."
GROUP filterGroup3
DESCRIPTION "The filterGroup3 is an optional group containing
objects providing information about Broadcast
Suppression Violation for port filtering
feature."
GROUP portGroup3
DESCRIPTION "The portGroup3 is an optional group containing
objects providing information about additional
information about the ports on the device."
GROUP portCpbGroup5
DESCRIPTION "The portCpbGroup5 is an optional group containing
objects providing additional information about
the port capabilities on the device."
GROUP authenticationGroup1
DESCRIPTION "The authenticationGroup1 is an optional group
containing objects providing information about the
authentication features."
::= { ciscoStackMIBCompliances 6 }
ciscoStackgMIBCompliance7 MODULE-COMPLIANCE
STATUS current
DESCRIPTION "The compliance statement for entities which
implement the Cisco stack MIB."
MODULE -- this module
MANDATORY-GROUPS {
systemMiscGroup1,
systemTrapGroup2,
chassisGroup,
moduleGroup,
portGroup4
}
GROUP optionalSystemMiscGroup
DESCRIPTION "The OptionalSystemMiscGroup is an optional group
containing objects providing information about
the miscellaneous system features."
GROUP optionalChassisGroup1
DESCRIPTION "The OptionalChassisGroup1 is an optional group
containing objects providing information about the
chassis of the device."
GROUP optionalModuleGroup
DESCRIPTION "The OptionalMooduleGroup is an optional group
containing objects providing information about the
modules on the device."
GROUP optionalPortGroup1
DESCRIPTION "The OptionalPortGroup1 is an optional group
containing objects providing information about the
ports on the device."
GROUP systemTrafficGroup
DESCRIPTION "The systemTrafficGroup is an optional group
containing objects providing information about the
traffic meter feature."
GROUP systemFddiGroup
DESCRIPTION "The systemFddiGroup is an optional group
containing objects providing information about the
FDDI ring feature."
GROUP systemRmonGroup
DESCRIPTION "The systemRmonGroup is an optional group
containing objects providing information about the
extended RMON feature."
GROUP tftpGroup
DESCRIPTION "The tftpGroup is an optional group containing
objects providing information about the tftp
upload/download features."
GROUP brouteEnableGroup
DESCRIPTION "The brouteEnableGroup is an optional group
containing objects providing information about the
combined bridging/routing feature."
GROUP filterGroup
DESCRIPTION "The filterGroup is an optional group containing
objects providing information about the port
filtering feature."
GROUP vlanGroup2
DESCRIPTION "The vlanGroup2 is an optional group containing
objects providing information about the Virtual
LAN features."
GROUP vmpsGroup
DESCRIPTION "The vmps is an optional group containing objects
providing information about the Vlan Membership
Policy Server feature."
GROUP tokenRingGroup
DESCRIPTION "The tokenRingGroup is an optional group
containing objects providing information about
the tokenring features."
GROUP mcastGroup
DESCRIPTION "The mcastGroup is an optional group containing
objects providing information about the multicast
features."
GROUP dnsGroup
DESCRIPTION "The dnsGroup is an optional group containing
objects providing information about the DNS
feature."
GROUP syslogGroup
DESCRIPTION "The syslogGroup is an optional group containing
objects providing information about the system log
feature."
GROUP ntpGroup
DESCRIPTION "The ntpGroup is an optional group containing
objects providing information about the network
time protocol feature."
GROUP ipPermitGroup2
DESCRIPTION "The ipPermitGroup2 is an optional group
containing objects providing information
about the ip permit list feature."
GROUP mdgGatewayGroup
DESCRIPTION "The mdgGatewayGroup is an optional group
containing objects providing information about
the multiple default gateway feature."
GROUP traceRouteGroup
DESCRIPTION "The traceRouteGroup is an optional group
containing objects providing information about
the trace route feature."
GROUP ntpAuthenticationGroup
DESCRIPTION "The ntpAuthenticationGroup is an optional group
containing objects providing information about the
network time protocol authentication feature."
GROUP tokenRingSoftErrorMonitorGroup
DESCRIPTION "The tokenRingSoftErrorMonitorGroup is an optional
group containing objects providing information
about the token ring port soft error monitoring
feature."
GROUP portCpbGroup1
DESCRIPTION "The portCpbGroup1 is an optional group containing
objects providing additional information about the
port capabilities on the device."
GROUP portSecurityGroup1
DESCRIPTION "The portSecurityGroup1 is an optional group
containing objects providing additional
information for supporting port security feature
with the multiple secured source MAC addresses."
GROUP fileCopyGroup
DESCRIPTION "The fileCopyGroup is an optional group containing
objects providing information about the tftp/rcp
or local file upload/download features."
GROUP optionalSystemMiscGroup1
DESCRIPTION "The optionalSystemMiscGroup1 is an optional group
containing objects providing information about the
miscellaneous system features."
GROUP ipPermitGroup1
DESCRIPTION "The ipPermitGroup1 is an optional group
containing objects providing information about
the ip permit list feature."
GROUP optionalSystemMiscGroup6
DESCRIPTION "The optionalSystemMiscGroup6 is an optional group
containing objects providing information about the
miscellaneous system features."
GROUP filterGroup1
DESCRIPTION "The filterGroup1 is an optional group containing
objects providing information about the port
filtering feature."
GROUP mcastGroup1
DESCRIPTION "The mcastGroup1 is an optional group containing
objects providing information about the
multicast features."
GROUP portGroup1
DESCRIPTION "The portGroup1 is an optional group containing
objects providing information about the ports on
the device."
GROUP chassisGroup1
DESCRIPTION "The chassisGroup1 is a group containing objects
providing information about the chassis of the
device. This group must be implemented by systems
that can have 3 or more power supplies."
GROUP moduleGroup1
DESCRIPTION "The moduleGroup1 is an optional group containing
objects providing information about the modules
on the device."
GROUP portCpbGroup2
DESCRIPTION "The portCpbGroup2 is an optional group containing
objects providing additional information about the
port capabilities on the device."
GROUP voiceGroup
DESCRIPTION "The voiceGroup is an optional group containing
objects providing information about the voice port
on the device."
GROUP moduleGroup2
DESCRIPTION "The moduleGroup2 is an mandatory group
containing objects providing information about
the modules on the device."
GROUP portCpbGroup3
DESCRIPTION "The portCpbGroup3 is an optional group containing
objects providing additional information about the
port capabilities on the device."
GROUP portGroup2
DESCRIPTION "The portGroup2 is an optional group containing
objects providing information about the ports on
the device."
GROUP switchAccelerationModuleGroup
DESCRIPTION "This group is mandatory for implementations of
switch acceleration capability."
GROUP optionalSystemMiscGroup3
DESCRIPTION "The optionalSystemMiscGroup3 is an optional group
containing objects providing information about the
miscellaneous system features."
GROUP optionalSystemMiscGroup4
DESCRIPTION "This group is an optional group containing
objects providing information about the
miscellaneous system features."
GROUP vlanTrunkMappingGroup
DESCRIPTION "This group is mandatory for implementations of
trunk VLAN to VLAN association feature on the
device."
GROUP portJumboFrameGroup
DESCRIPTION "This group is mandatory for implementations of
port jumbo frame feature on the device."
GROUP portCpbGroup4
DESCRIPTION "The portCpbGroup4 is an optional group containing
objects providing additional information about the
port capabilities on the device."
GROUP fileCopyGroup2
DESCRIPTION "The fileCopyGroup2 is an optional group
containing objects providing additional
information about tftp/rcp or local file
upload/download features."
GROUP systemRmonGroup2
DESCRIPTION "The systemRmonGroup2 is an optional group
containing objects providing information about
RMON max memory usage control."
GROUP filterGroup2
DESCRIPTION "The filterGroup2 is an optional group containing
objects providing information about the
unicast/multicast port filtering feature."
GROUP optionalSystemMiscGroup5
DESCRIPTION "The optionalSystemMiscGroup5 is an optional group
containing objects providing information about
miscellaneous system features."
GROUP syslogGroup2
DESCRIPTION "The syslogGroup2 is an optional group containing
objects providing information about whether the
syslog messages should be sent to telnet
sessions."
GROUP systemStatusGroup
DESCRIPTION "The systemStatusGroup is an optional group
containing objects providing information about
system LED status."
GROUP configurationGroup
DESCRIPTION "The configurationGroup is an optional group
containing objects providing information about
the configuration mode to store the configuration
information."
GROUP filterGroup3
DESCRIPTION "The filterGroup3 is an optional group containing
objects providing information about Broadcast
Suppression Violation for port filtering
feature."
GROUP portGroup3
DESCRIPTION "The portGroup3 is an optional group containing
objects providing information about additional
information about the ports on the device."
GROUP portCpbGroup5
DESCRIPTION "The portCpbGroup5 is an optional group containing
objects providing additional information about
the port capabilities on the device."
GROUP optionalSystemTrapGroup1
DESCRIPTION "The OptionalSystemTrapGroup1 is an optional group
containing objects providing information about the
SNMP traps feature."
GROUP authenticationGroup2
DESCRIPTION "The authenticationGroup2 is an optional group
containing objects providing information about the
authentication features."
GROUP notificationGroup
DESCRIPTION "The notificationGroup is an optional group
containing notifications supported on the device."
::= { ciscoStackMIBCompliances 7 }
-- units of conformance
systemMiscGroup OBJECT-GROUP
OBJECTS {
sysMgmtType,
sysIpAddr, -- deprecated
sysNetMask, -- deprecated
sysBroadcast, -- deprecated
sysAttachType,
sysReset, -- deprecated
sysBaudRate,
sysInsertMode,
sysClearMacTime, -- deprecated
sysClearPortTime, -- deprecated
sysEnableModem,
sysEnableRedirects,
sysArpAgingTime,
sysCommunityRwa,
sysCommunityRw,
sysCommunityRo,
sysIpVlan
}
STATUS deprecated
DESCRIPTION "A collection of objects providing information
about the miscellaneous system features."
::= { ciscoStackMIBGroups 1 }
systemTrapGroup OBJECT-GROUP
OBJECTS {
sysTrapReceiverAddr, -- deprecated
sysTrapReceiverType, -- deprecated
sysTrapReceiverComm, -- deprecated
sysEnableChassisTraps,
sysEnableModuleTraps,
sysEnableBridgeTraps,
sysEnableRepeaterTraps
}
STATUS deprecated
DESCRIPTION "A collection of objects providing information
about the SNMP traps feature."
::= { ciscoStackMIBGroups 2 }
chassisGroup OBJECT-GROUP
OBJECTS {
chassisSysType,
chassisBkplType,
chassisPs1Type,
chassisPs1Status,
chassisPs1TestResult,
chassisPs2Type,
chassisPs2Status,
chassisPs2TestResult,
chassisFanStatus,
chassisFanTestResult,
chassisMinorAlarm,
chassisMajorAlarm,
chassisTempAlarm,
chassisNumSlots
}
STATUS current
DESCRIPTION "A collection of objects providing information
about the chassis of the device.
Implementation of this group is mandatory."
::= { ciscoStackMIBGroups 3 }
moduleGroup OBJECT-GROUP
OBJECTS {
moduleIndex,
moduleType,
moduleStatus,
moduleTestResult,
moduleAction,
moduleName,
moduleNumPorts,
modulePortStatus,
moduleSubType,
moduleSerialNumberString
}
STATUS current
DESCRIPTION "A collection of objects providing information
about the modules on the device.
Implementation of this group is mandatory."
::= { ciscoStackMIBGroups 4 }
portGroup OBJECT-GROUP
OBJECTS {
portModuleIndex,
portIndex,
portCrossIndex,
portName,
portType,
portOperStatus,
portCrossGroupIndex,
portAdditionalStatus,
portAdminSpeed,
portDuplex,
portIfIndex,
portSpantreeFastStart, -- deprecated
portAdminRxFlowControl,
portOperRxFlowControl,
portAdminTxFlowControl,
portOperTxFlowControl,
portMacControlTransmitFrames,
portMacControlReceiveFrames,
portMacControlPauseTransmitFrames,
portMacControlPauseReceiveFrames,
portMacControlUnknownProtocolFrames,
portLinkFaultStatus
}
STATUS deprecated
DESCRIPTION "A collection of objects providing information
about the ports on the device."
::= { ciscoStackMIBGroups 5 }
optionalSystemMiscGroup OBJECT-GROUP
OBJECTS {
sysConfigChangeTime,
sysBannerMotd,
sysConfigChangeInfo,
sysConfigRegister,
sysBootVariable,
sysBootedImage
}
STATUS current
DESCRIPTION "A collection of objects providing information
about the miscellaneous system features.
Implementation of this group is optional."
::= { ciscoStackMIBGroups 6 }
optionalSystemTrapGroup OBJECT-GROUP
OBJECTS {
sysEnableIpPermitTraps,
sysEnableVmpsTraps,
sysEnableConfigTraps,
sysEnableEntityTrap,
sysEnableStpxTrap
}
STATUS deprecated
DESCRIPTION "A collection of objects providing information
about the SNMP traps feature.
Implementation of this group is optional."
::= { ciscoStackMIBGroups 7 }
optionalChassisGroup OBJECT-GROUP
OBJECTS {
chassisPs1TestResult,
chassisPs2TestResult,
chassisFanTestResult,
chassisSlotConfig,
chassisModel,
chassisComponentIndex, -- deprecated
chassisComponentType, -- deprecated
chassisComponentSerialNumber, -- deprecated
chassisComponentHwVersion, -- deprecated
chassisComponentModel, -- deprecated
chassisSerialNumberString -- deprecated
}
STATUS deprecated
DESCRIPTION "A collection of objects providing information
about the chassis of the device."
::= { ciscoStackMIBGroups 8 }
optionalModuleGroup OBJECT-GROUP
OBJECTS {
moduleTestResult,
moduleModel,
moduleHwVersion,
moduleFwVersion,
moduleSwVersion,
moduleStandbyStatus,
moduleIPAddress,
moduleIPAddressVlan,
moduleSubType2,
moduleSlotNum
}
STATUS current
DESCRIPTION "A collection of objects providing information
about the modules on the device.
Implementation of this group is Optional."
::= { ciscoStackMIBGroups 9 }
optionalPortGroup OBJECT-GROUP
OBJECTS {
portSecurityModuleIndex,
portSecurityPortIndex,
portSecurityAdminStatus,
portSecurityOperStatus,
portSecurityLastSrcAddr,
portSecuritySecureSrcAddr,
portChannelModuleIndex, -- deprecated
portChannelPortIndex, -- deprecated
portChannelPorts, -- deprecated
portChannelAdminStatus, -- deprecated
portChannelOperStatus, -- deprecated
portChannelNeighbourDeviceId, -- deprecated
portChannelNeighbourPortId, -- deprecated
portChannelProtInPackets, -- deprecated
portChannelProtOutPackets, -- deprecated
portChannelIfIndex, -- deprecated
portCpbModuleIndex,
portCpbPortIndex,
portCpbSpeed,
portCpbDuplex,
portCpbTrunkEncapsulationType,
portCpbTrunkMode,
portCpbChannel,
portCpbBroadcastSuppression,
portCpbFlowControl,
portCpbSecurity,
portCpbVlanMembership,
portCpbPortfast,
portTopNControlIndex,
portTopNRateBase,
portTopNType,
portTopNMode,
portTopNReportStatus,
portTopNDuration,
portTopNTimeRemaining,
portTopNStartTime,
portTopNRequestedSize,
portTopNGrantedSize,
portTopNOwner,
portTopNStatus,
portTopNIndex,
portTopNModuleNumber,
portTopNPortNumber,
portTopNUtilization,
portTopNIOOctets,
portTopNIOPkts,
portTopNIOBroadcast,
portTopNIOMulticast,
portTopNInErrors,
portTopNBufferOverFlow
}
STATUS deprecated
DESCRIPTION "A collection of objects providing information
about the ports on the device.
Implementation of this group is Optional."
::= { ciscoStackMIBGroups 10 }
systemTrafficGroup OBJECT-GROUP
OBJECTS {
sysTrafficMeterType,
sysTraffic,
sysTrafficPeak,
sysTrafficPeakTime,
sysTrafficMeter,
sysTrafficMeterPeak,
sysTrafficMeterPeakTime
}
STATUS current
DESCRIPTION "A collection of objects providing information
about the traffic meter feature.
Implementation of this group is optional. If the
traffic meter feature is supported, the entire
group should be implemented."
::= { ciscoStackMIBGroups 11 }
systemFddiGroup OBJECT-GROUP
OBJECTS {
sysFddiRingSMTIndex,
sysFddiRingAddress,
sysFddiRingNext
}
STATUS current
DESCRIPTION "A collection of objects providing information
about the FDDI ring feature.
Implementation of this group is optional. If the
FDDI ring feature is supported, the entire group
should be implemented."
::= { ciscoStackMIBGroups 12 }
systemRmonGroup OBJECT-GROUP
OBJECTS {
sysEnableRmon,
sysExtendedRmonVlanModeEnable,
sysExtendedRmonNetflowPassword,
sysExtendedRmonNetflowEnable,
sysExtendedRmonVlanAgentEnable,
sysExtendedRmonEnable
}
STATUS current
DESCRIPTION "A collection of objects providing information
about the extended RMON feature.
Implementation of this group is optional. If the
extended RMON feature is supported, the entire
group should be implemented."
::= { ciscoStackMIBGroups 13 }
authenticationGroup OBJECT-GROUP
OBJECTS {
sysConsolePrimaryLoginAuthentication, -- deprecated
sysConsolePrimaryEnableAuthentication, -- deprecated
sysTelnetPrimaryLoginAuthentication, -- deprecated
sysTelnetPrimaryEnableAuthentication, -- deprecated
tacacsLoginAuthentication, -- deprecated
tacacsEnableAuthentication, -- deprecated
tacacsLocalLoginAuthentication, -- deprecated
tacacsLocalEnableAuthentication, -- deprecated
tacacsNumLoginAttempts, -- deprecated
tacacsDirectedRequest,
tacacsTimeout, -- deprecated
tacacsAuthKey,
tacacsServerAddr,
tacacsServerType,
radiusLoginAuthentication, -- deprecated
radiusEnableAuthentication, -- deprecated
radiusDeadtime,
radiusAuthKey,
radiusTimeout,
radiusRetransmits,
radiusServerAddr,
radiusServerAuthPort,
radiusServerType
}
STATUS deprecated
DESCRIPTION "A collection of objects providing information
about the authentication features.
Implementation of this group is optional. If the
authentication features are supported, the entire
group should be implemented."
::= { ciscoStackMIBGroups 14 }
tftpGroup OBJECT-GROUP
OBJECTS {
tftpHost,
tftpFile,
tftpModule,
tftpAction,
tftpResult
}
STATUS current
DESCRIPTION "A collection of objects providing information
about the tftp upload/download features.
Implementation of this group is optional. If the
tftp upload/download features are supported, the
entire group should be implemented."
::= { ciscoStackMIBGroups 15 }
brouteEnableGroup OBJECT-GROUP
OBJECTS {
brouterPortModule,
brouterPort,
brouterEnableRip,
brouterEnableSpantree,
brouterEnableGiantCheck,
brouterEnableIpFragmentation,
brouterEnableUnreachables,
brouterCamMode,
brouterIpxSnapToEther,
brouterIpx8023RawToFddi,
brouterEthernetReceiveMax,
brouterEthernetTransmitMax,
brouterFddiReceiveMax,
brouterFddiTransmitMax,
brouterPortIpVlan,
brouterPortIpAddr,
brouterPortNetMask,
brouterPortBroadcast,
brouterPortBridgeVlan,
brouterPortIpHelpers,
brouterIpx8022ToEther,
brouterEnableTransitEncapsulation,
brouterEnableFddiCheck,
brouterEnableAPaRT
}
STATUS current
DESCRIPTION "A collection of objects providing information
about the combined bridging/routing feature.
Implementation of this group is optional. If the
combined bridging/routing feature is supported,
the group should be implemented."
::= { ciscoStackMIBGroups 16 }
filterGroup OBJECT-GROUP
OBJECTS {
filterMacModule,
filterMacPort,
filterMacAddress,
filterMacType,
filterVendorModule,
filterVendorPort,
filterVendorId,
filterVendorType,
filterProtocolModule,
filterProtocolPort,
filterProtocolValue,
filterProtocolType,
filterTestModule,
filterTestPort,
filterTestIndex,
filterTestType,
filterTestOffset,
filterTestValue,
filterTestMask,
filterPortModule,
filterPort,
filterPortComplex,
filterPortBroadcastThrottle,
filterPortBroadcastThreshold,
filterPortBroadcastDiscards
}
STATUS current
DESCRIPTION "A collection of objects providing information
about the port filtering feature.
Implementation of this group is optional. If the
port filtering feature is supported, parts or all
of this group should be implemented."
::= { ciscoStackMIBGroups 17 }
monitorGroup OBJECT-GROUP
OBJECTS {
monitorSourceModule,
monitorSourcePort,
monitorDestinationModule,
monitorDestinationPort,
monitorDirection,
monitorEnable,
monitorAdminSourcePorts,
monitorOperSourcePorts
}
STATUS deprecated
DESCRIPTION "The collection of deprecated objects for
managing the Switched Port Analyzer (SPAN)
features."
::= { ciscoStackMIBGroups 18 }
vlanGroup OBJECT-GROUP
OBJECTS {
vlanIndex, -- deprecated
vlanSpantreeEnable, -- deprecated
vlanIfIndex, -- deprecated
vlanPortModule,
vlanPort,
vlanPortVlan,
vlanPortIslVlansAllowed,
vlanPortSwitchLevel,
vlanPortIslAdminStatus,
vlanPortIslOperStatus,
vlanPortIslPriorityVlans,
vlanPortAdminStatus,
vlanPortOperStatus
}
STATUS deprecated
DESCRIPTION "A collection of objects providing information
about the Virtual LAN features.
Implementation of this group is optional."
::= { ciscoStackMIBGroups 19 }
vmpsGroup OBJECT-GROUP
OBJECTS {
vmpsAddr,
vmpsType,
vmpsAction,
vmpsAccessed
}
STATUS current
DESCRIPTION "A collection of objects providing information
about the Vlan Membership Policy Server feature.
Implementation of this group is optional. If the
Vlan Membership Policy Server feature is
supported, the entire group should be
implemented."
::= { ciscoStackMIBGroups 20 }
tokenRingGroup OBJECT-GROUP
OBJECTS {
tokenRingModuleIndex,
tokenRingPortIndex,
tokenRingPortSetACbits ,
tokenRingPortMode ,
tokenRingPortEarlyTokenRel,
tokenRingPortPriorityThresh,
tokenRingPortPriorityMinXmit,
tokenRingPortCfgLossThresh,
tokenRingPortCfgLossInterval,
tokenRingDripDistCrfMode,
tokenRingDripAreReductionMode,
tokenRingDripLocalNodeID,
tokenRingDripLastRevision,
tokenRingDripLastChangedRevision,
tokenRingDripAdvertsReceived,
tokenRingDripAdvertsTransmitted,
tokenRingDripAdvertsProcessed,
tokenRingDripInputQueueDrops,
tokenRingDripOutputQueueDrops,
tokenRingDripVlan,
tokenRingDripLocalPortStatus,
tokenRingDripRemotePortStatus,
tokenRingDripRemotePortConfigured,
tokenRingDripDistributedCrf,
tokenRingDripBackupCrf,
tokenRingDripOwnerNodeID
}
STATUS current
DESCRIPTION "A collection of objects providing information
about the token ring features.
Implementation of this group is optional. If the
token ring features are supported, the entire
group should be implemented."
::= { ciscoStackMIBGroups 21 }
mcastGroup OBJECT-GROUP
OBJECTS {
mcastRouterModuleIndex,
mcastRouterPortIndex,
mcastRouterAdminStatus,
mcastRouterOperStatus,
mcastEnableCgmp,
mcastEnableIgmp
}
STATUS current
DESCRIPTION "A collection of objects providing information
about the multicast features.
Implementation of this group is optional. If the
multicast features are supported, the entire group
should be implemented."
::= { ciscoStackMIBGroups 22 }
dnsGroup OBJECT-GROUP
OBJECTS {
dnsEnable,
dnsServerAddr,
dnsServerType,
dnsDomainName
}
STATUS current
DESCRIPTION "A collection of objects providing information
about the DNS feature.
Implementation of this group is optional. If the
DNS feature is supported, the entire group
should be implemented."
::= { ciscoStackMIBGroups 23 }
syslogGroup OBJECT-GROUP
OBJECTS {
syslogServerAddr,
syslogServerType,
syslogConsoleEnable,
syslogHostEnable,
syslogMessageFacility,
syslogMessageSeverity,
syslogTimeStampOption
}
STATUS current
DESCRIPTION "A collection of objects providing information
about the system log feature.
Implementation of this group is optional. If the
system log feature is supported, the entire group
should be implemented."
::= { ciscoStackMIBGroups 24 }
ntpGroup OBJECT-GROUP
OBJECTS {
ntpBcastClient,
ntpBcastDelay,
ntpClient,
ntpServerAddress,
ntpServerType,
ntpSummertimeStatus,
ntpSummerTimezoneName,
ntpTimezoneName,
ntpTimezoneOffsetHour,
ntpTimezoneOffsetMinute
}
STATUS current
DESCRIPTION "A collection of objects providing information
about the network time protocol feature.
Implementation of this group is optional. If the
network time protocol feature is supported, the
entire group should be implemented."
::= { ciscoStackMIBGroups 25 }
ipPermitGroup OBJECT-GROUP
OBJECTS {
ipPermitAddress,
ipPermitMask,
ipPermitEnable, -- deprecated
ipPermitType,
ipPermitDeniedAddress,
ipPermitDeniedAccess,
ipPermitDeniedTime
}
STATUS deprecated
DESCRIPTION "A collection of objects providing information
about the ip permit list feature.
Implementation of this group is optional. If the
ip permit list feature is supported, the entire
group should be implemented."
::= { ciscoStackMIBGroups 26 }
mdgGatewayGroup OBJECT-GROUP
OBJECTS {
mdgGatewayAddr,
mdgGatewayType
}
STATUS current
DESCRIPTION "A collection of objects providing information
about the multiple default gateway feature.
Implementation of this group is optional. If the
multiple default gateway feature is supported,
the entire group should be implemented."
::= { ciscoStackMIBGroups 27 }
traceRouteGroup OBJECT-GROUP
OBJECTS {
traceRouteMaxQueries,
traceRouteQueryIndex,
traceRouteHost,
traceRouteQueryDNSEnable,
traceRouteQueryWaitingTime,
traceRouteQueryInitTTL,
traceRouteQueryMaxTTL,
traceRouteQueryUDPPort,
traceRouteQueryPacketCount,
traceRouteQueryPacketSize,
traceRouteQueryTOS,
traceRouteQueryResult,
traceRouteQueryTime,
traceRouteQueryOwner,
traceRouteQueryStatus,
traceRouteDataIndex,
traceRouteDataGatewayName,
traceRouteDataGatewayIp,
traceRouteDataRtt,
traceRouteDataHopCount,
traceRouteDataErrors
}
STATUS current
DESCRIPTION "A collection of objects providing information
about the trace route feature.
Implementation of this group is optional. If the
trace route feature is supported, the entire group
should be implemented."
::= { ciscoStackMIBGroups 28 }
deprecatedObjectGroup OBJECT-GROUP
OBJECTS {
sysCommunityAccess,
sysCommunityString,
moduleHwHiVersion,
moduleHwLoVersion,
moduleFwHiVersion,
moduleFwLoVersion,
moduleSwHiVersion,
moduleSwLoVersion,
brouterCamAgingTime,
chassisSerialNumber,
moduleSerialNumber
}
STATUS deprecated
DESCRIPTION "A collection of objects that have been
deprecated."
::= { ciscoStackMIBGroups 29 }
ntpAuthenticationGroup OBJECT-GROUP
OBJECTS {
ntpServerPublicKey,
ntpAuthenticationEnable,
ntpAuthenticationPublicKey,
ntpAuthenticationSecretKey,
ntpAuthenticationTrustedMode,
ntpAuthenticationType
}
STATUS current
DESCRIPTION "A collection of objects providing information
about the network time protocol authentication
feature.
Implementation of this group is optional. If the
network time protocol authentication feature is
supported, the entire group should be
implemented."
::= { ciscoStackMIBGroups 30 }
tokenRingSoftErrorMonitorGroup OBJECT-GROUP
OBJECTS {
tokenRingPortSoftErrThresh,
tokenRingPortSoftErrReportInterval,
tokenRingPortSoftErrResetCounters,
tokenRingPortSoftErrLastCounterReset,
tokenRingPortSoftErrEnable
}
STATUS current
DESCRIPTION "A collection of objects providing information
about the token ring port soft error monitoring
feature.
Implementation of this group is optional. If the
token ring features are supported, the entire
group should be implemented."
::= { ciscoStackMIBGroups 31 }
portCpbGroup1 OBJECT-GROUP
OBJECTS {
portCpbUdld
}
STATUS current
DESCRIPTION "A collection of objects providing additional
information about the port capabilities on the
device.
Implementation of this group is Optional."
::= { ciscoStackMIBGroups 32 }
portSecurityGroup1 OBJECT-GROUP
OBJECTS {
portSecurityMaxSrcAddr,
portSecurityAgingTime,
portSecurityShutdownTimeOut,
portSecurityViolationPolicy,
portSecurityExtModuleIndex,
portSecurityExtPortIndex,
portSecurityExtSecureSrcAddr,
portSecurityExtControlStatus
}
STATUS current
DESCRIPTION "A collection of objects providing additional
information for supporting port security feature
with the multiple secured source MAC addresses.
Implementation of this group is optional."
::= { ciscoStackMIBGroups 33}
fileCopyGroup OBJECT-GROUP
OBJECTS {
fileCopyProtocol,
fileCopyRemoteServer,
fileCopySrcFileName,
fileCopyDstFileName,
fileCopyModuleNumber,
fileCopyUserName,
fileCopyAction,
fileCopyResult,
fileCopyResultRcpErrorMessage
}
STATUS current
DESCRIPTION "A collection of objects providing information
about the tftp/rcp or local file upload/download
features.
Implementation of this group is optional. If the
tftp upload/download features are supported, the
entire group should be implemented."
::= { ciscoStackMIBGroups 34 }
optionalSystemMiscGroup1 OBJECT-GROUP
OBJECTS {
sysStartupConfigSource,
sysStartupConfigSourceFile,
sysConfigSupervisorModuleNo,
sysStandbyPortEnable
}
STATUS current
DESCRIPTION "A collection of objects providing information
about the miscellaneous system features.
Implementation of this group is optional."
::= { ciscoStackMIBGroups 35 }
ipPermitGroup1 OBJECT-GROUP
OBJECTS {
ipPermitAccessType
}
STATUS current
DESCRIPTION "A collection of objects providing additional
information for allowing the ip permit host with
the specified access type.
Implementation of this group is optional. If the
ip permit list enhancement feature is supported,
this group should be implemented."
::= { ciscoStackMIBGroups 36 }
optionalSystemMiscGroup2 OBJECT-GROUP
OBJECTS {
sysPortFastBpduGuard, -- deprecated
sysErrDisableTimeoutEnable,
sysErrDisableTimeoutInterval,
sysTrafficMonitorHighWaterMark,
sysHighAvailabilityEnable,
sysHighAvailabilityVersioningEnable,
sysHighAvailabilityOperStatus,
sysHighAvailabilityNotRunningReason
}
STATUS deprecated
DESCRIPTION "A collection of objects providing information
about the miscellaneous system features.
Implementation of this group is optional."
::= { ciscoStackMIBGroups 37 }
filterGroup1 OBJECT-GROUP
OBJECTS {
filterPortBroadcastThresholdFraction
}
STATUS current
DESCRIPTION "A collection of objects providing information
about the port filtering feature.
Implementation of this group is optional. If the
port filtering feature is supported, parts or all
of this group should be implemented."
::= { ciscoStackMIBGroups 38 }
mcastGroup1 OBJECT-GROUP
OBJECTS {
mcastEnableRgmp
}
STATUS current
DESCRIPTION "A collection of objects providing information
about the multicast features.
Implementation of this group is optional. If the
multicast features are supported, the entire group
should be implemented."
::= { ciscoStackMIBGroups 39 }
portGroup1 OBJECT-GROUP
OBJECTS {
portAdditionalOperStatus,
portEntPhysicalIndex
}
STATUS current
DESCRIPTION "A collection of objects providing information
about the ports on the device.
Implementation of this group is optional."
::= { ciscoStackMIBGroups 40 }
chassisGroup1 OBJECT-GROUP
OBJECTS {
chassisPs3Type,
chassisPs3Status,
chassisPs3TestResult,
chassisPEMInstalled
}
STATUS current
DESCRIPTION "A collection of objects providing information
about the chassis of the device.
This group must be implemented by systems that can
have 3 or more power supplies."
::= { ciscoStackMIBGroups 41 }
moduleGroup1 OBJECT-GROUP
OBJECTS {
moduleEntPhysicalIndex
}
STATUS current
DESCRIPTION "A collection of objects providing information
about the modules on the device.
Implementation of this group is mandatory."
::= { ciscoStackMIBGroups 42 }
portCpbGroup2 OBJECT-GROUP
OBJECTS {
portCpbSpan
}
STATUS current
DESCRIPTION "A collection of objects providing additional
information about the port capabilities on the
device.
Implementation of this group is Optional."
::= { ciscoStackMIBGroups 43 }
voiceGroup OBJECT-GROUP
OBJECTS {
voicePortIfDHCPEnabled,
voicePortIfIpAddress,
voicePortIfIpNetMask,
voicePortIfTftpServerAddress,
voicePortIfGatewayAddress,
voicePortIfDnsServerAddress,
voicePortIfDnsDomain,
voicePortIfOperDnsDomain,
voicePortCallManagerIpAddr,
voicePortOperDnsServerIpAddr,
voicePortOperDnsServerSource
}
STATUS current
DESCRIPTION "A collection of objects providing information
about the voice ports on the device.
Implemetation of this group is Optional"
::= { ciscoStackMIBGroups 44 }
portGroup2 OBJECT-GROUP
OBJECTS {
portInlinePowerDetect
}
STATUS current
DESCRIPTION "A collection of objects providing information
about the ports on the device.
Implementation of this group is optional."
::= { ciscoStackMIBGroups 45 }
vlanGroup1 OBJECT-GROUP
OBJECTS {
vlanPortAuxiliaryVlan
}
STATUS deprecated
DESCRIPTION "A collection of objects providing information
about the Virtual LAN features.
Implementation of this group is optional. If the
Virtual LAN features are supported, the entire
group should be implemented."
::= { ciscoStackMIBGroups 46 }
portCpbGroup3 OBJECT-GROUP
OBJECTS {
portCpbInlinePower,
portCpbAuxiliaryVlan
}
STATUS current
DESCRIPTION "A collection of objects providing additional
information about the port capabilities on the
device.
Implementation of this group is Optional."
::= { ciscoStackMIBGroups 47 }
moduleGroup2 OBJECT-GROUP
OBJECTS {
moduleAdditionalStatus
}
STATUS current
DESCRIPTION "A collection of objects providing information
about the modules on the device.
Implementation of this group is mandatory."
::= { ciscoStackMIBGroups 48 }
switchAccelerationModuleGroup OBJECT-GROUP
OBJECTS {
switchAccelerationModuleIndex,
switchAccelerationModuleEnable
}
STATUS current
DESCRIPTION "A collection of objects providing information
about the modules switch acceleration
configuration.
Implementation of this group is mandatory if the
module switch acceleration feature is supported."
::= { ciscoStackMIBGroups 49 }
optionalSystemMiscGroup3 OBJECT-GROUP
OBJECTS {
sysExtendedRmonNetflowModuleMask
}
STATUS current
DESCRIPTION "A collection of objects providing information
about the miscellaneous system features.
The sysExtendedRmonNetflowModuleMask object is
optional object and it will only be supported in
the platform supporting multiple NAM (Network
Analysis Module) cards.
Implementation of this group is optional."
::= { ciscoStackMIBGroups 50 }
optionalSystemMiscGroup4 OBJECT-GROUP
OBJECTS {
sshPublicKeySize
}
STATUS current
DESCRIPTION "A collection of objects providing information
about the miscellaneous system features."
::= { ciscoStackMIBGroups 51 }
vlanTrunkMappingGroup OBJECT-GROUP
OBJECTS {
vlanTrunkMappingMax,
vlanTrunkMappingToVlan,
vlanTrunkMappingType,
vlanTrunkMappingOper,
vlanTrunkMappingStatus
}
STATUS current
DESCRIPTION "A collection of objects providing information
about the trunk VLAN to VLAN associations.
Implementation of this group is mandatory if the
trunk VLAN to VLAN association feature is
supported on the device."
::= { ciscoStackMIBGroups 52 }
portJumboFrameGroup OBJECT-GROUP
OBJECTS {
portJumboFrameModuleIndex,
portJumboFramePortIndex,
portJumboFrameEnable
}
STATUS current
DESCRIPTION "A collection of objects providing information
about the port jumbo frame feature on the device.
Implementation of this group is mandatory if the
port jumbo frame feature is supported on the
device."
::= { ciscoStackMIBGroups 53 }
portCpbGroup4 OBJECT-GROUP
OBJECTS {
portCpbCosRewrite,
portCpbTosRewrite,
portCpbCopsGrouping
}
STATUS current
DESCRIPTION "A collection of objects providing additional
information about the port capabilities on the
device.
Implementation of this group is Optional."
::= { ciscoStackMIBGroups 54 }
fileCopyGroup2 OBJECT-GROUP
OBJECTS { fileCopyRuntimeConfigPart }
STATUS current
DESCRIPTION "A collection of objects providing additional
information about tftp/rcp or local file
upload/download features.
Implementation of this group is optional."
::= { ciscoStackMIBGroups 55 }
systemRmonGroup2 OBJECT-GROUP
OBJECTS { sysMaxRmonMemory }
STATUS current
DESCRIPTION "A collection of object providing RMON max memory
usage control."
::= { ciscoStackMIBGroups 56 }
filterGroup2 OBJECT-GROUP
OBJECTS {
filterPortSuppressionOption
}
STATUS current
DESCRIPTION "A collection of objects providing information
about the unicast/multicast port filtering
feature."
::= { ciscoStackMIBGroups 57 }
optionalSystemMiscGroup5 OBJECT-GROUP
OBJECTS { sysMacReductionAdminEnable,
sysMacReductionOperEnable
}
STATUS current
DESCRIPTION "A collection of objects providing information
about the miscellaneous system features."
::= { ciscoStackMIBGroups 58 }
syslogGroup2 OBJECT-GROUP
OBJECTS {
syslogTelnetEnable
}
STATUS current
DESCRIPTION "A collection of object providing control about
whether the syslog messages should be sent to
telnet sessions.
Implementation of this group is optional."
::= { ciscoStackMIBGroups 59 }
systemStatusGroup OBJECT-GROUP
OBJECTS { sysStatus }
STATUS current
DESCRIPTION "A collection of object providing the system
LED status.
Implementation of this group is optional."
::= { ciscoStackMIBGroups 60 }
configurationGroup OBJECT-GROUP
OBJECTS { configMode,
configTextFileLocation,
configWriteMem,
configWriteMemStatus
}
STATUS current
DESCRIPTION "A collection of object providing the information
about the configuration mode to store the
configuration information.
Implementation of this group is optional."
::= { ciscoStackMIBGroups 61 }
filterGroup3 OBJECT-GROUP
OBJECTS {
filterPortSuppressionViolation
}
STATUS current
DESCRIPTION "A collection of objects providing additional
information about about the Broadcast
Suppression Violation for port filtering feature.
Implementation of this group is optional."
::= { ciscoStackMIBGroups 62 }
portGroup3 OBJECT-GROUP
OBJECTS {
portErrDisableTimeOutEnable
}
STATUS current
DESCRIPTION "A collection of objects providing additional
information about the ports on the device.
Implementation of this group is optional."
::= { ciscoStackMIBGroups 63 }
portCpbGroup5 OBJECT-GROUP
OBJECTS {
portCpbDot1x,
portCpbIgmpFilter
}
STATUS current
DESCRIPTION "A collection of objects providing additional
information about the port capabilities on the
device.
Implementation of this group is Optional."
::= { ciscoStackMIBGroups 64 }
authenticationGroup1 OBJECT-GROUP
OBJECTS {
tacacsDirectedRequest,
tacacsAuthKey,
tacacsServerAddr,
tacacsServerType,
radiusDeadtime,
radiusAuthKey,
radiusTimeout,
radiusRetransmits,
radiusServerAddr,
radiusServerAuthPort,
radiusServerType
}
STATUS deprecated
DESCRIPTION "A collection of objects providing information
about the authentication features.
Implementation of this group is optional."
::= { ciscoStackMIBGroups 65 }
systemMiscGroup1 OBJECT-GROUP
OBJECTS {
sysMgmtType,
sysAttachType,
sysBaudRate,
sysInsertMode,
sysEnableModem,
sysEnableRedirects,
sysArpAgingTime,
sysCommunityRwa,
sysCommunityRw,
sysCommunityRo,
sysIpVlan
}
STATUS current
DESCRIPTION "A collection of objects providing information
about the miscellaneous system features."
::= { ciscoStackMIBGroups 66 }
systemTrapGroup1 OBJECT-GROUP
OBJECTS {
sysEnableChassisTraps,
sysEnableModuleTraps,
sysEnableBridgeTraps,
sysEnableRepeaterTraps
}
STATUS deprecated
DESCRIPTION "A collection of objects providing information
about the SNMP traps feature."
::= { ciscoStackMIBGroups 67 }
optionalSystemMiscGroup6 OBJECT-GROUP
OBJECTS {
sysErrDisableTimeoutEnable,
sysErrDisableTimeoutInterval,
sysTrafficMonitorHighWaterMark,
sysHighAvailabilityEnable,
sysHighAvailabilityVersioningEnable,
sysHighAvailabilityOperStatus,
sysHighAvailabilityNotRunningReason
}
STATUS current
DESCRIPTION "A collection of objects providing information
about the miscellaneous system features.
Implementation of this group is optional."
::= { ciscoStackMIBGroups 68 }
optionalChassisGroup1 OBJECT-GROUP
OBJECTS {
chassisPs1TestResult,
chassisPs2TestResult,
chassisFanTestResult,
chassisSlotConfig,
chassisModel
}
STATUS current
DESCRIPTION "A collection of objects providing information
about the chassis of the device."
::= { ciscoStackMIBGroups 69 }
portGroup4 OBJECT-GROUP
OBJECTS {
portModuleIndex,
portIndex,
portCrossIndex,
portName,
portType,
portOperStatus,
portCrossGroupIndex,
portAdditionalStatus,
portAdminSpeed,
portDuplex,
portIfIndex,
portAdminRxFlowControl,
portOperRxFlowControl,
portAdminTxFlowControl,
portOperTxFlowControl,
portMacControlTransmitFrames,
portMacControlReceiveFrames,
portMacControlPauseTransmitFrames,
portMacControlPauseReceiveFrames,
portMacControlUnknownProtocolFrames,
portLinkFaultStatus
}
STATUS current
DESCRIPTION "A collection of objects providing information
about the ports on the device."
::= { ciscoStackMIBGroups 70 }
vlanGroup2 OBJECT-GROUP
OBJECTS {
vlanPortModule,
vlanPort,
vlanPortVlan,
vlanPortIslVlansAllowed,
vlanPortSwitchLevel,
vlanPortIslAdminStatus,
vlanPortIslOperStatus,
vlanPortIslPriorityVlans,
vlanPortAdminStatus,
vlanPortOperStatus
}
STATUS current
DESCRIPTION "A collection of objects providing information
about the Virtual LAN features.
Implementation of this group is optional."
::= { ciscoStackMIBGroups 71 }
ipPermitGroup2 OBJECT-GROUP
OBJECTS {
ipPermitAddress,
ipPermitMask,
ipPermitType,
ipPermitDeniedAddress,
ipPermitDeniedAccess,
ipPermitDeniedTime,
ipPermitAccessTypeEnable
}
STATUS current
DESCRIPTION "A collection of objects providing information
about the ip permit list feature.
Implementation of this group is optional. If the
ip permit list feature is supported, the entire
group should be implemented."
::= { ciscoStackMIBGroups 72 }
optionalPortGroup1 OBJECT-GROUP
OBJECTS {
portSecurityModuleIndex,
portSecurityPortIndex,
portSecurityAdminStatus,
portSecurityOperStatus,
portSecurityLastSrcAddr,
portSecuritySecureSrcAddr,
portCpbModuleIndex,
portCpbPortIndex,
portCpbSpeed,
portCpbDuplex,
portCpbTrunkEncapsulationType,
portCpbTrunkMode,
portCpbChannel,
portCpbBroadcastSuppression,
portCpbFlowControl,
portCpbSecurity,
portCpbVlanMembership,
portCpbPortfast,
portTopNControlIndex,
portTopNRateBase,
portTopNType,
portTopNMode,
portTopNReportStatus,
portTopNDuration,
portTopNTimeRemaining,
portTopNStartTime,
portTopNRequestedSize,
portTopNGrantedSize,
portTopNOwner,
portTopNStatus,
portTopNIndex,
portTopNModuleNumber,
portTopNPortNumber,
portTopNUtilization,
portTopNIOOctets,
portTopNIOPkts,
portTopNIOBroadcast,
portTopNIOMulticast,
portTopNInErrors,
portTopNBufferOverFlow
}
STATUS current
DESCRIPTION "A collection of objects providing information
about the ports on the device.
Implementation of this group is Optional."
::= { ciscoStackMIBGroups 73 }
optionalSystemTrapGroup1 OBJECT-GROUP
OBJECTS {
sysEnableIpPermitTraps,
sysEnableVmpsTraps,
sysEnableConfigTraps,
sysEnableEntityTrap
}
STATUS current
DESCRIPTION "A collection of objects providing information
about the SNMP traps feature.
Implementation of this group is optional."
::= { ciscoStackMIBGroups 74 }
authenticationGroup2 OBJECT-GROUP
OBJECTS {
tacacsDirectedRequest,
tacacsAuthKey,
tacacsServerAddr,
tacacsServerType,
radiusDeadtime,
radiusAuthKey,
radiusTimeout,
radiusRetransmits
}
STATUS current
DESCRIPTION "A collection of objects providing information
about the authentication features.
Implementation of this group is optional."
::= { ciscoStackMIBGroups 75 }
systemTrapGroup2 OBJECT-GROUP
OBJECTS {
sysEnableChassisTraps,
sysEnableModuleTraps,
sysEnableRepeaterTraps
}
STATUS current
DESCRIPTION "A collection of objects providing information
about the SNMP traps feature."
::= { ciscoStackMIBGroups 76 }
notificationGroup NOTIFICATION-GROUP
NOTIFICATIONS {
lerAlarmOn,
lerAlarmOff,
moduleUp,
moduleDown,
chassisAlarmOn,
chassisAlarmOff,
ipPermitDeniedTrap,
sysConfigChangeTrap,
tokenRingSoftErrExceededTrap
}
STATUS current
DESCRIPTION
"A collection of notifications supported on the device."
::= { ciscoStackMIBGroups 77 }