549 lines
18 KiB
Plaintext
549 lines
18 KiB
Plaintext
-- Changes for RFC1317 (RS-232 MIB)
|
|
-- No changes needed.
|
|
-- dperkins@scruznet.com
|
|
|
|
|
|
RFC1317-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
Counter
|
|
FROM RFC1155-SMI
|
|
transmission
|
|
FROM RFC1213-MIB
|
|
OBJECT-TYPE
|
|
FROM RFC-1212;
|
|
|
|
-- this is the MIB module for RS-232-like hardware devices
|
|
|
|
rs232 OBJECT IDENTIFIER ::= { transmission 33 }
|
|
|
|
|
|
-- the generic RS-232-like group
|
|
|
|
-- Implementation of this group is mandatory for all
|
|
-- systems that have RS-232-like hardware ports
|
|
-- supporting higher level services such as character
|
|
-- streams or network interfaces
|
|
|
|
rs232Number OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of ports (regardless of their current
|
|
state) in the RS-232-like general port table."
|
|
::= { rs232 1 }
|
|
|
|
|
|
-- the RS-232-like general Port table
|
|
|
|
rs232PortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Rs232PortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of port entries. The number of entries is
|
|
given by the value of rs232Number."
|
|
::= { rs232 2 }
|
|
|
|
rs232PortEntry OBJECT-TYPE
|
|
SYNTAX Rs232PortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Status and parameter values for a port."
|
|
INDEX { rs232PortIndex }
|
|
::= { rs232PortTable 1 }
|
|
|
|
Rs232PortEntry ::=
|
|
SEQUENCE {
|
|
rs232PortIndex
|
|
INTEGER,
|
|
rs232PortType
|
|
INTEGER,
|
|
rs232PortInSigNumber
|
|
INTEGER,
|
|
rs232PortOutSigNumber
|
|
INTEGER,
|
|
rs232PortInSpeed
|
|
INTEGER,
|
|
rs232PortOutSpeed
|
|
INTEGER }
|
|
|
|
rs232PortIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A unique value for each port. Its value ranges
|
|
between 1 and the value of rs232Number. By
|
|
convention and if possible, hardware port numbers
|
|
map directly to external connectors. The value for
|
|
each port must remain constant at least from one
|
|
re-initialization of the network management agent to
|
|
the next."
|
|
::= { rs232PortEntry 1 }
|
|
|
|
rs232PortType OBJECT-TYPE
|
|
SYNTAX INTEGER { other(1), rs232(2), rs422(3),
|
|
rs423(4), v35(5) }
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The port's hardware type."
|
|
::= { rs232PortEntry 2 }
|
|
|
|
rs232PortInSigNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of input signals for the port in the
|
|
input signal table (rs232PortInSigTable). The table
|
|
contains entries only for those signals the software
|
|
can detect."
|
|
::= { rs232PortEntry 3 }
|
|
|
|
rs232PortOutSigNumber OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of output signals for the port in the
|
|
output signal table (rs232PortOutSigTable). The
|
|
table contains entries only for those signals the
|
|
software can assert."
|
|
::= { rs232PortEntry 4 }
|
|
|
|
rs232PortInSpeed OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The port's input speed in bits per second."
|
|
::= { rs232PortEntry 5 }
|
|
|
|
rs232PortOutSpeed OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The port's output speed in bits per second."
|
|
::= { rs232PortEntry 6 }
|
|
|
|
|
|
-- the RS-232-like Asynchronous Port group
|
|
|
|
-- Implementation of this group is mandatory if the system
|
|
-- has any asynchronous ports. Otherwise it is not
|
|
-- present.
|
|
|
|
rs232AsyncPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Rs232AsyncPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of asynchronous port entries. The maximum
|
|
entry number is given by the value of rs232Number.
|
|
Entries need not exist for synchronous ports."
|
|
::= { rs232 3 }
|
|
|
|
rs232AsyncPortEntry OBJECT-TYPE
|
|
SYNTAX Rs232AsyncPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Status and parameter values for an asynchronous
|
|
port."
|
|
INDEX { rs232AsyncPortIndex }
|
|
::= { rs232AsyncPortTable 1 }
|
|
|
|
Rs232AsyncPortEntry ::=
|
|
SEQUENCE {
|
|
rs232AsyncPortIndex
|
|
INTEGER,
|
|
rs232AsyncPortBits
|
|
INTEGER,
|
|
rs232AsyncPortStopBits
|
|
INTEGER,
|
|
rs232AsyncPortParity
|
|
INTEGER,
|
|
rs232AsyncPortAutobaud
|
|
INTEGER,
|
|
rs232AsyncPortParityErrs
|
|
Counter,
|
|
rs232AsyncPortFramingErrs
|
|
Counter,
|
|
rs232AsyncPortOverrunErrs
|
|
Counter
|
|
|
|
}
|
|
|
|
rs232AsyncPortIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A unique value for each port. Its value is the
|
|
same as rs232PortIndex for the port."
|
|
::= { rs232AsyncPortEntry 1 }
|
|
|
|
rs232AsyncPortBits OBJECT-TYPE
|
|
SYNTAX INTEGER (5..8)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The port's number of bits in a character."
|
|
::= { rs232AsyncPortEntry 2 }
|
|
|
|
rs232AsyncPortStopBits OBJECT-TYPE
|
|
SYNTAX INTEGER { one(1), two(2),
|
|
one-and-half(3), dynamic(4) }
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The port's number of stop bits."
|
|
::= { rs232AsyncPortEntry 3 }
|
|
|
|
rs232AsyncPortParity OBJECT-TYPE
|
|
SYNTAX INTEGER { none(1), odd(2), even(3),
|
|
mark(4), space(5) }
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The port's sense of a character parity bit."
|
|
::= { rs232AsyncPortEntry 4 }
|
|
|
|
rs232AsyncPortAutobaud OBJECT-TYPE
|
|
SYNTAX INTEGER { enabled(1), disabled(2) }
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A control for the port's ability to automatically
|
|
sense input speed.
|
|
|
|
When rs232PortAutoBaud is 'enabled', a port may
|
|
autobaud to values different from the set values for
|
|
speed, parity, and character size. As a result a
|
|
network management system may temporarily observe
|
|
values different from what was previously set."
|
|
::= { rs232AsyncPortEntry 5 }
|
|
|
|
rs232AsyncPortParityErrs OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Total number of characters with a parity error,
|
|
input from the port since system re-initialization
|
|
and while the port state was 'up' or 'test'."
|
|
::= { rs232AsyncPortEntry 6 }
|
|
|
|
rs232AsyncPortFramingErrs OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Total number of characters with a framing error,
|
|
input from the port since system re-initialization
|
|
and while the port state was 'up' or 'test'."
|
|
::= { rs232AsyncPortEntry 7 }
|
|
|
|
rs232AsyncPortOverrunErrs OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Total number of characters with an overrun error,
|
|
input from the port since system re-initialization
|
|
and while the port state was 'up' or 'test'."
|
|
::= { rs232AsyncPortEntry 8 }
|
|
|
|
|
|
-- the RS-232-like Synchronous Port group
|
|
|
|
-- Implementation of this group is mandatory if the system
|
|
-- has any synchronous ports. Otherwise it is not
|
|
-- present.
|
|
|
|
rs232SyncPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Rs232SyncPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of synchronous port entries. The maximum
|
|
entry number is given by the value of rs232Number.
|
|
Entries need not exist for asynchronous ports."
|
|
::= { rs232 4 }
|
|
|
|
rs232SyncPortEntry OBJECT-TYPE
|
|
SYNTAX Rs232SyncPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Status and parameter values for a synchronous
|
|
port."
|
|
INDEX { rs232SyncPortIndex }
|
|
::= { rs232SyncPortTable 1 }
|
|
|
|
Rs232SyncPortEntry ::=
|
|
SEQUENCE {
|
|
rs232SyncPortIndex
|
|
INTEGER,
|
|
rs232SyncPortClockSource
|
|
INTEGER,
|
|
rs232SyncPortFrameCheckErrs
|
|
Counter,
|
|
rs232SyncPortTransmitUnderrunErrs
|
|
Counter,
|
|
rs232SyncPortReceiveOverrunErrs
|
|
Counter,
|
|
rs232SyncPortInterruptedFrames
|
|
Counter,
|
|
rs232SyncPortAbortedFrames
|
|
Counter
|
|
}
|
|
|
|
rs232SyncPortIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A unique value for each port. Its value is the
|
|
same as rs232PortIndex for the port."
|
|
::= { rs232SyncPortEntry 1 }
|
|
|
|
rs232SyncPortClockSource OBJECT-TYPE
|
|
SYNTAX INTEGER { internal(1), external(2), split(3) }
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Source of the port's bit rate clock. 'split' means
|
|
the tranmit clock is internal and the receive clock
|
|
is external."
|
|
::= { rs232SyncPortEntry 2 }
|
|
|
|
rs232SyncPortFrameCheckErrs OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Total number of frames with an invalid frame check
|
|
sequence, input from the port since system
|
|
re-initialization and while the port state was 'up'
|
|
or 'test'."
|
|
::= { rs232SyncPortEntry 3 }
|
|
|
|
rs232SyncPortTransmitUnderrunErrs OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Total number of frames that failed to be
|
|
transmitted on the port since system
|
|
re-initialization and while the port state was 'up'
|
|
or 'test' because data was not available to the
|
|
transmitter in time."
|
|
::= { rs232SyncPortEntry 4 }
|
|
|
|
rs232SyncPortReceiveOverrunErrs OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Total number of frames that failed to be received
|
|
on the port since system re-initialization and while
|
|
the port state was 'up' or 'test' because the
|
|
receiver did not accept the data in time."
|
|
::= { rs232SyncPortEntry 5 }
|
|
|
|
rs232SyncPortInterruptedFrames OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Total number of frames that failed to be received
|
|
or transmitted on the port due to loss of modem
|
|
signals since system re-initialization and while the
|
|
port state was 'up' or 'test'."
|
|
::= { rs232SyncPortEntry 6 }
|
|
|
|
rs232SyncPortAbortedFrames OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of frames aborted on the port due to
|
|
receiving an abort sequence since system
|
|
re-initialization and while the port state was 'up'
|
|
or 'test'."
|
|
::= { rs232SyncPortEntry 7 }
|
|
|
|
|
|
-- the Input Signal table
|
|
|
|
rs232InSigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Rs232InSigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of port input control signal entries."
|
|
::= { rs232 5 }
|
|
|
|
rs232InSigEntry OBJECT-TYPE
|
|
SYNTAX Rs232InSigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Input control signal status for a hardware port."
|
|
INDEX { rs232InSigPortIndex, rs232InSigName }
|
|
::= { rs232InSigTable 1 }
|
|
|
|
Rs232InSigEntry ::=
|
|
SEQUENCE {
|
|
rs232InSigPortIndex
|
|
INTEGER,
|
|
rs232InSigName
|
|
INTEGER,
|
|
rs232InSigState
|
|
INTEGER,
|
|
rs232InSigChanges
|
|
Counter
|
|
}
|
|
|
|
rs232InSigPortIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The value of rs232PortIndex for the port to which
|
|
this entry belongs."
|
|
::= { rs232InSigEntry 1 }
|
|
|
|
rs232InSigName OBJECT-TYPE
|
|
SYNTAX INTEGER { rts(1), cts(2), dsr(3), dtr(4), ri(5),
|
|
dcd(6), sq(7), srs(8), srts(9),
|
|
scts(10), sdcd(11) }
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Identification of a hardware signal, as follows:
|
|
|
|
rts Request to Send
|
|
cts Clear to Send
|
|
dsr Data Set Ready
|
|
dtr Data Terminal Ready
|
|
ri Ring Indicator
|
|
dcd Received Line Signal Detector
|
|
sq Signal Quality Detector
|
|
srs Data Signaling Rate Selector
|
|
srts Secondary Request to Send
|
|
scts Secondary Clear to Send
|
|
sdcd Secondary Received Line Signal Detector
|
|
"
|
|
REFERENCE
|
|
"EIA Standard RS-232-C, August 1969."
|
|
::= { rs232InSigEntry 2 }
|
|
|
|
rs232InSigState OBJECT-TYPE
|
|
SYNTAX INTEGER { none(1), on(2), off(3) }
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current signal state."
|
|
::= { rs232InSigEntry 3 }
|
|
|
|
rs232InSigChanges OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of times the signal has changed from
|
|
'on' to 'off' or from 'off' to 'on'."
|
|
::= { rs232InSigEntry 4 }
|
|
|
|
|
|
-- the Output Signal table
|
|
|
|
rs232OutSigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF Rs232OutSigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A list of port output control signal entries."
|
|
::= { rs232 6 }
|
|
|
|
rs232OutSigEntry OBJECT-TYPE
|
|
SYNTAX Rs232OutSigEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Output control signal status for a hardware port."
|
|
INDEX { rs232OutSigPortIndex, rs232OutSigName }
|
|
::= { rs232OutSigTable 1 }
|
|
|
|
Rs232OutSigEntry ::=
|
|
SEQUENCE {
|
|
rs232OutSigPortIndex
|
|
INTEGER,
|
|
rs232OutSigName
|
|
INTEGER,
|
|
rs232OutSigState
|
|
INTEGER,
|
|
rs232OutSigChanges
|
|
Counter
|
|
}
|
|
|
|
rs232OutSigPortIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The value of rs232PortIndex for the port to which
|
|
this entry belongs."
|
|
::= { rs232OutSigEntry 1 }
|
|
|
|
rs232OutSigName OBJECT-TYPE
|
|
SYNTAX INTEGER { rts(1), cts(2), dsr(3), dtr(4), ri(5),
|
|
dcd(6), sq(7), srs(8), srts(9),
|
|
scts(10), sdcd(11) }
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Identification of a hardware signal, as follows:
|
|
|
|
rts Request to Send
|
|
cts Clear to Send
|
|
dsr Data Set Ready
|
|
dtr Data Terminal Ready
|
|
ri Ring Indicator
|
|
dcd Received Line Signal Detector
|
|
sq Signal Quality Detector
|
|
srs Data Signaling Rate Selector
|
|
srts Secondary Request to Send
|
|
scts Secondary Clear to Send
|
|
sdcd Secondary Received Line Signal Detector
|
|
"
|
|
REFERENCE
|
|
"EIA Standard RS-232-C, August 1969."
|
|
::= { rs232OutSigEntry 2 }
|
|
|
|
rs232OutSigState OBJECT-TYPE
|
|
SYNTAX INTEGER { none(1), on(2), off(3) }
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current signal state."
|
|
::= { rs232OutSigEntry 3 }
|
|
|
|
rs232OutSigChanges OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of times the signal has changed from
|
|
'on' to 'off' or from 'off' to 'on'."
|
|
::= { rs232OutSigEntry 4 }
|
|
|
|
END
|