2626 lines
112 KiB
Plaintext
2626 lines
112 KiB
Plaintext
-- Changes to rfc1382 (X.25 Packet Layer MIB):
|
|
-- No changes needed.
|
|
-- dperkins@scruznet.com
|
|
|
|
RFC1382-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
Counter, Gauge, TimeTicks
|
|
FROM RFC1155-SMI
|
|
OBJECT-TYPE
|
|
FROM RFC-1212
|
|
DisplayString, transmission
|
|
FROM RFC1213-MIB
|
|
TRAP-TYPE
|
|
FROM RFC-1215
|
|
EntryStatus
|
|
FROM RFC1271-MIB
|
|
PositiveInteger,
|
|
IfIndexType
|
|
FROM RFC1381-MIB;
|
|
|
|
x25 OBJECT IDENTIFIER ::= { transmission 5 }
|
|
|
|
-- Support of the X25 subtree and all subtrees under it
|
|
-- is mandatory for all agents of system that implement X.25.
|
|
|
|
X121Address ::= OCTET STRING (SIZE(0..17))
|
|
-- 0 to 17 bytes in length containing the ASCII
|
|
-- characters [0-9], each octet contains one digit
|
|
-- of the address.
|
|
|
|
-- ###########################################################
|
|
-- X.25 Administration Table
|
|
-- ###########################################################
|
|
|
|
x25AdmnTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF X25AdmnEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This table contains the administratively
|
|
set configuration parameters for an X.25
|
|
Packet Level Entity (PLE).
|
|
|
|
Most of the objects in this table have
|
|
corresponding objects in the x25OperTable.
|
|
This table contains the values as last set
|
|
by the administrator. The x25OperTable
|
|
contains the values actually in use by an
|
|
X.25 PLE.
|
|
|
|
Changing an administrative value may or may
|
|
not change a current operating value. The
|
|
operating value may not change until the
|
|
interface is restarted. Some
|
|
implementations may change the values
|
|
immediately upon changing the administrative
|
|
table. All implementations are required to
|
|
load the values from the administrative
|
|
table when initializing a PLE."
|
|
::= { x25 1 }
|
|
|
|
x25AdmnEntry OBJECT-TYPE
|
|
SYNTAX X25AdmnEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Entries of x25AdmnTable."
|
|
INDEX { x25AdmnIndex }
|
|
::= { x25AdmnTable 1 }
|
|
|
|
X25AdmnEntry ::= SEQUENCE {
|
|
x25AdmnIndex
|
|
IfIndexType,
|
|
x25AdmnInterfaceMode
|
|
INTEGER,
|
|
x25AdmnMaxActiveCircuits
|
|
INTEGER,
|
|
x25AdmnPacketSequencing
|
|
INTEGER,
|
|
x25AdmnRestartTimer
|
|
PositiveInteger,
|
|
x25AdmnCallTimer
|
|
PositiveInteger,
|
|
x25AdmnResetTimer
|
|
PositiveInteger,
|
|
x25AdmnClearTimer
|
|
PositiveInteger,
|
|
x25AdmnWindowTimer
|
|
PositiveInteger,
|
|
x25AdmnDataRxmtTimer
|
|
PositiveInteger,
|
|
x25AdmnInterruptTimer
|
|
PositiveInteger,
|
|
x25AdmnRejectTimer
|
|
PositiveInteger,
|
|
x25AdmnRegistrationRequestTimer
|
|
PositiveInteger,
|
|
x25AdmnMinimumRecallTimer
|
|
PositiveInteger,
|
|
x25AdmnRestartCount
|
|
INTEGER,
|
|
x25AdmnResetCount
|
|
INTEGER,
|
|
x25AdmnClearCount
|
|
INTEGER,
|
|
x25AdmnDataRxmtCount
|
|
INTEGER,
|
|
x25AdmnRejectCount
|
|
INTEGER,
|
|
x25AdmnRegistrationRequestCount
|
|
INTEGER,
|
|
x25AdmnNumberPVCs
|
|
INTEGER,
|
|
x25AdmnDefCallParamId
|
|
OBJECT IDENTIFIER,
|
|
x25AdmnLocalAddress
|
|
X121Address,
|
|
x25AdmnProtocolVersionSupported
|
|
OBJECT IDENTIFIER
|
|
}
|
|
|
|
x25AdmnIndex OBJECT-TYPE
|
|
SYNTAX IfIndexType
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The ifIndex value for the X.25 Interface."
|
|
::= { x25AdmnEntry 1 }
|
|
|
|
x25AdmnInterfaceMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
dte (1),
|
|
dce (2),
|
|
dxe (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Identifies DCE/DTE mode in which the
|
|
interface operates. A value of dxe
|
|
indicates the mode will be determined by XID
|
|
negotiation."
|
|
REFERENCE "10733 5.9 interfaceMode"
|
|
::= { x25AdmnEntry 2 }
|
|
|
|
x25AdmnMaxActiveCircuits OBJECT-TYPE
|
|
SYNTAX INTEGER (0..4096)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum number of circuits this PLE can
|
|
support; including PVCs."
|
|
REFERENCE "10733 5.9 maxActiveCircuits;
|
|
See ISO 8208, Section 3.7"
|
|
::= { x25AdmnEntry 3 }
|
|
|
|
x25AdmnPacketSequencing OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
modulo8 (1),
|
|
modulo128 (2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The modulus of the packet sequence number
|
|
space."
|
|
REFERENCE "10733 extendedPacketSequencing;
|
|
See ISO 8208 Section 7.1.1"
|
|
::= { x25AdmnEntry 4 }
|
|
|
|
x25AdmnRestartTimer OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The T20 restart timer in milliseconds."
|
|
REFERENCE "10733 5.9 restartTime
|
|
See ISO 8208 Section 4.1, table 26"
|
|
::= { x25AdmnEntry 5 }
|
|
|
|
|
|
x25AdmnCallTimer OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The T21 Call timer in milliseconds."
|
|
REFERENCE "10733 callTime;
|
|
See ISO 8208 Section 5.2.1, table 26"
|
|
::= { x25AdmnEntry 6 }
|
|
|
|
x25AdmnResetTimer OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The T22 Reset timer in milliseconds."
|
|
REFERENCE "10733 resetTime;
|
|
See ISO 8208 Section 8.1, table 26"
|
|
::= { x25AdmnEntry 7 }
|
|
|
|
x25AdmnClearTimer OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The T23 Clear timer in milliseconds."
|
|
REFERENCE "10733 clearTime;
|
|
See ISO 8208 Section 5.5.1, table 26"
|
|
::= { x25AdmnEntry 8 }
|
|
|
|
x25AdmnWindowTimer OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The T24 window status transmission timer in
|
|
milliseconds. A value of 2147483647
|
|
indicates no window timer in use."
|
|
REFERENCE "10733 5.10.1 windowTime (opt);
|
|
See ISO 8208 Section 11.2.2, table 26"
|
|
::= { x25AdmnEntry 9 }
|
|
|
|
x25AdmnDataRxmtTimer OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The T25 data retransmission timer in
|
|
milliseconds. A value of 2147483647
|
|
indicates no data retransmission timer in
|
|
use."
|
|
REFERENCE "10733 5.10.1 dataRetransmissionTime (opt);
|
|
See ISO 8208 Section 11.2.1, table 26"
|
|
::= { x25AdmnEntry 10 }
|
|
|
|
x25AdmnInterruptTimer OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The T26 interrupt timer in milliseconds. A
|
|
value of 2147483647 indicates no interrupt
|
|
timer in use."
|
|
REFERENCE "10733 interruptTime;
|
|
See ISO 8208 Section 6.8.1, table 26"
|
|
::= { x25AdmnEntry 11 }
|
|
|
|
x25AdmnRejectTimer OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The T27 Reject retransmission timer in
|
|
milliseconds. A value of 2147483647
|
|
indicates no reject timer in use."
|
|
REFERENCE "10733 5.10.1 dataRejectTime (opt);
|
|
See ISO 8208 Section 13.4.1, table 26"
|
|
::= { x25AdmnEntry 12 }
|
|
|
|
x25AdmnRegistrationRequestTimer OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The T28 registration timer in milliseconds.
|
|
A value of 2147483647 indicates no
|
|
registration timer in use."
|
|
REFERENCE "10733 5.8.1 registrationRequestTime (opt)
|
|
See ISO 8208 Section 13.1.1.1, table 26"
|
|
::= { x25AdmnEntry 13 }
|
|
|
|
x25AdmnMinimumRecallTimer OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Minimum time interval between unsuccessful
|
|
call attempts in milliseconds."
|
|
REFERENCE "10733 5.9 minimum RecallTimer"
|
|
::= { x25AdmnEntry 14 }
|
|
|
|
x25AdmnRestartCount OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The R20 restart retransmission count."
|
|
REFERENCE "10733 5.9 restartCount;
|
|
See ISO 8208 Section 4.1, table 27"
|
|
::= { x25AdmnEntry 15 }
|
|
|
|
x25AdmnResetCount OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The r22 Reset retransmission count."
|
|
REFERENCE "10733 resetCount;
|
|
See section ISO 8208 8.1, table 27"
|
|
::= { x25AdmnEntry 16 }
|
|
|
|
x25AdmnClearCount OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The r23 Clear retransmission count."
|
|
REFERENCE "10733 clearCount;
|
|
See ISO 8208 Section 5.5.1, table 27"
|
|
::= { x25AdmnEntry 17 }
|
|
|
|
x25AdmnDataRxmtCount OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The R25 Data retransmission count. This
|
|
value is irrelevant if the
|
|
x25AdmnDataRxmtTimer indicates no timer in
|
|
use."
|
|
REFERENCE "10733 5.10.1 dataRetransmissionCount (opt)
|
|
See ISO 8208 Section 11.2.1, table 27"
|
|
::= { x25AdmnEntry 18 }
|
|
|
|
|
|
x25AdmnRejectCount OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The R27 reject retransmission count. This
|
|
value is irrelevant if the
|
|
x25AdmnRejectTimer indicates no timer in
|
|
use."
|
|
REFERENCE "10733 5.10.1 dataRejectCount (opt)"
|
|
::= { x25AdmnEntry 19 }
|
|
|
|
x25AdmnRegistrationRequestCount OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The R28 Registration retransmission Count.
|
|
This value is irrelevant if the
|
|
x25AdmnRegistrationRequestTimer indicates no
|
|
timer in use."
|
|
REFERENCE "10733 5.8.1 registrationRequestCount (opt);
|
|
See ISO 8208 Section 13.1.1.1, table 27"
|
|
::= { x25AdmnEntry 20 }
|
|
|
|
x25AdmnNumberPVCs OBJECT-TYPE
|
|
SYNTAX INTEGER (0..4096)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of PVC configured for this PLE.
|
|
The PVCs use channel numbers from 1 to this
|
|
number."
|
|
::= { x25AdmnEntry 21 }
|
|
|
|
x25AdmnDefCallParamId OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This identifies the instance of the
|
|
x25CallParmIndex for the entry in the
|
|
x25CallParmTable which contains the default
|
|
call parameters for this PLE."
|
|
::= { x25AdmnEntry 22 }
|
|
|
|
x25AdmnLocalAddress OBJECT-TYPE
|
|
SYNTAX X121Address
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The local address for this PLE subnetwork.
|
|
A zero length address maybe returned by PLEs
|
|
that only support PVCs."
|
|
REFERENCE "10733 5.9 localDTEAddress"
|
|
::= { x25AdmnEntry 23 }
|
|
|
|
x25AdmnProtocolVersionSupported OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Identifies the version of the X.25 protocol
|
|
this interface should support. Object
|
|
identifiers for common versions are defined
|
|
below in the x25ProtocolVersion subtree."
|
|
REFERENCE "10733 5.9 protocolVersionSupported"
|
|
::= { x25AdmnEntry 24 }
|
|
|
|
-- ###########################################################
|
|
-- X.25 Operational Table
|
|
-- ###########################################################
|
|
|
|
x25OperTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF X25OperEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The operation parameters in use by the X.25
|
|
PLE."
|
|
::= { x25 2 }
|
|
|
|
x25OperEntry OBJECT-TYPE
|
|
SYNTAX X25OperEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Entries of x25OperTable."
|
|
INDEX { x25OperIndex }
|
|
::= { x25OperTable 1 }
|
|
|
|
X25OperEntry ::= SEQUENCE {
|
|
x25OperIndex
|
|
IfIndexType,
|
|
x25OperInterfaceMode
|
|
INTEGER,
|
|
x25OperMaxActiveCircuits
|
|
INTEGER,
|
|
x25OperPacketSequencing
|
|
INTEGER,
|
|
x25OperRestartTimer
|
|
PositiveInteger,
|
|
x25OperCallTimer
|
|
PositiveInteger,
|
|
x25OperResetTimer
|
|
PositiveInteger,
|
|
x25OperClearTimer
|
|
PositiveInteger,
|
|
x25OperWindowTimer
|
|
PositiveInteger,
|
|
x25OperDataRxmtTimer
|
|
PositiveInteger,
|
|
x25OperInterruptTimer
|
|
PositiveInteger,
|
|
x25OperRejectTimer
|
|
PositiveInteger,
|
|
x25OperRegistrationRequestTimer
|
|
PositiveInteger,
|
|
x25OperMinimumRecallTimer
|
|
PositiveInteger,
|
|
x25OperRestartCount
|
|
INTEGER,
|
|
x25OperResetCount
|
|
INTEGER,
|
|
x25OperClearCount
|
|
INTEGER,
|
|
x25OperDataRxmtCount
|
|
INTEGER,
|
|
x25OperRejectCount
|
|
INTEGER,
|
|
x25OperRegistrationRequestCount
|
|
INTEGER,
|
|
x25OperNumberPVCs
|
|
INTEGER,
|
|
x25OperDefCallParamId
|
|
OBJECT IDENTIFIER,
|
|
x25OperLocalAddress
|
|
X121Address,
|
|
x25OperDataLinkId
|
|
OBJECT IDENTIFIER,
|
|
x25OperProtocolVersionSupported
|
|
OBJECT IDENTIFIER
|
|
}
|
|
|
|
|
|
x25OperIndex OBJECT-TYPE
|
|
SYNTAX IfIndexType
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The ifIndex value for the X.25 interface."
|
|
::= { x25OperEntry 1 }
|
|
|
|
x25OperInterfaceMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
dte (1),
|
|
dce (2),
|
|
dxe (3)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Identifies DCE/DTE mode in which the
|
|
interface operates. A value of dxe
|
|
indicates the role will be determined by XID
|
|
negotiation at the Link Layer and that
|
|
negotiation has not yet taken place."
|
|
REFERENCE "10733 5.9 interfaceMode"
|
|
::= { x25OperEntry 2 }
|
|
|
|
x25OperMaxActiveCircuits OBJECT-TYPE
|
|
SYNTAX INTEGER (0..4096)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Maximum number of circuits this PLE can
|
|
support."
|
|
REFERENCE "10733 5.9 maxActiveCircuits
|
|
See ISO 8208, Section 3.7"
|
|
::= { x25OperEntry 3 }
|
|
|
|
x25OperPacketSequencing OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
modulo8 (1),
|
|
modulo128 (2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The modulus of the packet sequence number
|
|
space."
|
|
REFERENCE "10733 extendedPacketSequencing;
|
|
See ISO 8208 Section 7.1.1"
|
|
::= { x25OperEntry 4 }
|
|
|
|
x25OperRestartTimer OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The T20 restart timer in milliseconds."
|
|
REFERENCE "10733 5.9 restartTime;
|
|
See ISO 8208 Section 4.1, table 26"
|
|
::= { x25OperEntry 5 }
|
|
|
|
x25OperCallTimer OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The T21 Call timer in milliseconds."
|
|
REFERENCE "10733 callTime;
|
|
See ISO 8208 Section 5.2.1, table 26"
|
|
::= { x25OperEntry 6 }
|
|
|
|
x25OperResetTimer OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The T22 Reset timer in milliseconds."
|
|
REFERENCE "10733 resetTime;
|
|
See ISO 8208 Section 8.1, table 26"
|
|
::= { x25OperEntry 7 }
|
|
|
|
x25OperClearTimer OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The T23 Clear timer in milliseconds."
|
|
REFERENCE "10733 clearTime;
|
|
See ISO 8208 Section 5.5.1, table 26"
|
|
::= { x25OperEntry 8 }
|
|
|
|
x25OperWindowTimer OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The T24 window status transmission timer
|
|
milliseconds. A value of 2147483647
|
|
indicates no window timer in use."
|
|
REFERENCE "10733 5.10.1 windowTime (opt);
|
|
See ISO 8208 Section 11.2.2, table 26"
|
|
::= { x25OperEntry 9 }
|
|
|
|
x25OperDataRxmtTimer OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The T25 Data Retransmission timer in
|
|
milliseconds. A value of 2147483647
|
|
indicates no data retransmission timer in
|
|
use."
|
|
REFERENCE "10733 5.10.1 dataRetransmissionTime (opt);
|
|
See ISO 8208 Section 11.2.1, table 26"
|
|
::= { x25OperEntry 10 }
|
|
|
|
x25OperInterruptTimer OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The T26 Interrupt timer in milliseconds. A
|
|
value of 2147483647 indicates interrupts are
|
|
not being used."
|
|
REFERENCE "10733 interruptTime;
|
|
See ISO 8208 Section 6.8.1, table 26"
|
|
::= { x25OperEntry 11 }
|
|
|
|
x25OperRejectTimer OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The T27 Reject retransmission timer in
|
|
milliseconds. A value of 2147483647
|
|
indicates no reject timer in use."
|
|
REFERENCE "10733 5.10.1 dataRejectTime (opt);
|
|
See ISO 8208 Section 13.4.1, table 26"
|
|
::= { x25OperEntry 12 }
|
|
|
|
x25OperRegistrationRequestTimer OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The T28 registration timer in milliseconds.
|
|
A value of 2147483647 indicates no
|
|
registration timer in use."
|
|
REFERENCE "10733 5.8.1 registrationRequestTime (opt);
|
|
See ISO 8208 Section 13.1.1.1, table 26"
|
|
::= { x25OperEntry 13 }
|
|
|
|
x25OperMinimumRecallTimer OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Minimum time interval between unsuccessful
|
|
call attempts in milliseconds."
|
|
REFERENCE "10733 5.9 minimum RecallTimer"
|
|
::= { x25OperEntry 14 }
|
|
|
|
x25OperRestartCount OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The R20 restart retransmission count."
|
|
REFERENCE "10733 5.9 restartCount
|
|
See ISO 8208 Section 4.1, table 27"
|
|
::= { x25OperEntry 15 }
|
|
|
|
x25OperResetCount OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The r22 Reset retransmission count."
|
|
REFERENCE "10733 resetCount;
|
|
See section ISO 8208 8.1, table 27"
|
|
::= { x25OperEntry 16 }
|
|
|
|
x25OperClearCount OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The r23 Clear retransmission count."
|
|
REFERENCE "10733 clearCount;
|
|
See ISO 8208 Section 5.5.1, table 27"
|
|
::= { x25OperEntry 17 }
|
|
|
|
x25OperDataRxmtCount OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The R25 Data retransmission count. This
|
|
value is undefined if the
|
|
x25OperDataRxmtTimer indicates no timer in
|
|
use."
|
|
REFERENCE "10733 5.10.1 dataRetransmissionCount (opt);
|
|
See ISO 8208 Section 11.2.1, table 27"
|
|
::= { x25OperEntry 18 }
|
|
|
|
x25OperRejectCount OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The R27 reject retransmission count. This
|
|
value is undefined if the x25OperRejectTimer
|
|
indicates no timer in use."
|
|
REFERENCE "10733 5.10.1 dataRejectCount (opt)"
|
|
::= { x25OperEntry 19 }
|
|
|
|
x25OperRegistrationRequestCount OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The R28 Registration retransmission Count.
|
|
This value is undefined if the
|
|
x25OperREgistrationRequestTimer indicates no
|
|
timer in use."
|
|
REFERENCE "10733 5.8.1 registrationRequestCount (opt);
|
|
See ISO 8208 Section 13.1.1.1, table 27"
|
|
::= { x25OperEntry 20 }
|
|
|
|
x25OperNumberPVCs OBJECT-TYPE
|
|
SYNTAX INTEGER (0..4096)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of PVC configured for this PLE.
|
|
The PVCs use channel numbers from 1 to this
|
|
number."
|
|
::= { x25OperEntry 21 }
|
|
|
|
x25OperDefCallParamId OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This identifies the instance of the
|
|
x25CallParmIndex for the entry in the
|
|
x25CallParmTable that contains the default
|
|
call parameters for this PLE."
|
|
::= { x25OperEntry 22 }
|
|
|
|
x25OperLocalAddress OBJECT-TYPE
|
|
SYNTAX X121Address
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The local address for this PLE subnetwork.
|
|
A zero length address maybe returned by PLEs
|
|
that only support PVCs."
|
|
REFERENCE "10733 5.9 localDTEAddress"
|
|
::= { x25OperEntry 23 }
|
|
|
|
x25OperDataLinkId OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This identifies the instance of the index
|
|
object in the first table of the most device
|
|
specific MIB for the interface used by this
|
|
PLE."
|
|
::= { x25OperEntry 24 }
|
|
|
|
x25OperProtocolVersionSupported OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Identifies the version of the X.25 protocol
|
|
this interface supports. Object identifiers
|
|
for common versions are defined below in the
|
|
x25ProtocolVersion subtree."
|
|
REFERENCE "10733 5.9 protocolVersionSupported"
|
|
::= { x25OperEntry 25 }
|
|
|
|
-- MIB-II also provides:
|
|
|
|
-- ifDescr:
|
|
-- On an X.25 interface this must include sufficient
|
|
|
|
|
|
-- information to enable the system's administrator
|
|
-- to determine the appropriate configuration
|
|
-- information on a system having multiple X.25
|
|
-- subnetworks.
|
|
|
|
-- ifType: ddn-x25 or rfc877-x25
|
|
-- an interface of type ddn-x25 will use an algorithm to
|
|
-- translate between X.121 address and IP addresses.
|
|
-- An interface of type rfc877-x25 will use a
|
|
-- configuration table to translate between X.121
|
|
-- addresses and IP addresses.
|
|
|
|
-- ifMtu: the maximum PDU a higher layer can pass to X.25 or
|
|
-- receive from X.25
|
|
|
|
-- ifSpeed:
|
|
-- This will be the value of the local clock for this line.
|
|
-- A value of zero indicates external clocking.
|
|
|
|
-- ifAdminStatus:
|
|
|
|
-- ifOperStatus
|
|
|
|
-- ifLastChange
|
|
|
|
-- ###########################################################
|
|
-- X.25 Statistics Table
|
|
-- ###########################################################
|
|
|
|
x25StatTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF X25StatEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Statistics information about this X.25
|
|
PLE."
|
|
::= { x25 3 }
|
|
|
|
x25StatEntry OBJECT-TYPE
|
|
SYNTAX X25StatEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Entries of the x25StatTable."
|
|
INDEX { x25StatIndex }
|
|
::= { x25StatTable 1 }
|
|
|
|
|
|
X25StatEntry ::= SEQUENCE {
|
|
x25StatIndex
|
|
IfIndexType,
|
|
x25StatInCalls
|
|
Counter,
|
|
x25StatInCallRefusals
|
|
Counter,
|
|
x25StatInProviderInitiatedClears
|
|
Counter,
|
|
x25StatInRemotelyInitiatedResets
|
|
Counter,
|
|
x25StatInProviderInitiatedResets
|
|
Counter,
|
|
x25StatInRestarts
|
|
Counter,
|
|
x25StatInDataPackets
|
|
Counter,
|
|
x25StatInAccusedOfProtocolErrors
|
|
Counter,
|
|
x25StatInInterrupts
|
|
Counter,
|
|
x25StatOutCallAttempts
|
|
Counter,
|
|
x25StatOutCallFailures
|
|
Counter,
|
|
x25StatOutInterrupts
|
|
Counter,
|
|
x25StatOutDataPackets
|
|
Counter,
|
|
x25StatOutgoingCircuits
|
|
Gauge,
|
|
x25StatIncomingCircuits
|
|
Gauge,
|
|
x25StatTwowayCircuits
|
|
Gauge,
|
|
x25StatRestartTimeouts
|
|
Counter,
|
|
x25StatCallTimeouts
|
|
Counter,
|
|
x25StatResetTimeouts
|
|
Counter,
|
|
x25StatClearTimeouts
|
|
Counter,
|
|
x25StatDataRxmtTimeouts
|
|
Counter,
|
|
x25StatInterruptTimeouts
|
|
Counter,
|
|
x25StatRetryCountExceededs
|
|
Counter,
|
|
x25StatClearCountExceededs
|
|
Counter
|
|
}
|
|
|
|
x25StatIndex OBJECT-TYPE
|
|
SYNTAX IfIndexType
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The ifIndex value for the X.25 interface."
|
|
::= { x25StatEntry 1 }
|
|
|
|
x25StatInCalls OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of incoming calls received."
|
|
::= { x25StatEntry 2 }
|
|
|
|
x25StatInCallRefusals OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of incoming calls refused. This
|
|
includes calls refused by the PLE and by
|
|
higher layers. This also includes calls
|
|
cleared because of restricted fast select."
|
|
::= { x25StatEntry 3 }
|
|
|
|
x25StatInProviderInitiatedClears OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of clear requests with a cause
|
|
code other than DTE initiated."
|
|
REFERENCE "10733 providerInitiatedDisconnect"
|
|
::= { x25StatEntry 4 }
|
|
|
|
x25StatInRemotelyInitiatedResets OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of reset requests received with
|
|
cause code DTE initiated."
|
|
REFERENCE "10733 remotelyInitiatedResets"
|
|
::= { x25StatEntry 5 }
|
|
|
|
x25StatInProviderInitiatedResets OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of reset requests received with
|
|
cause code other than DTE initiated."
|
|
REFERENCE "10733 ProviderInitiatedResets"
|
|
::= { x25StatEntry 6 }
|
|
|
|
x25StatInRestarts OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of remotely initiated (including
|
|
provider initiated) restarts experienced by
|
|
the PLE excluding the restart associated
|
|
with bringing up the PLE interface. This
|
|
only counts restarts received when the PLE
|
|
already has an established connection with
|
|
the remove PLE."
|
|
REFERENCE "10733 5.9 remotelyInitiatedRestarts"
|
|
::= { x25StatEntry 7 }
|
|
|
|
x25StatInDataPackets OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of data packets received."
|
|
REFERENCE "10733 5.9 dataPacketsReceived."
|
|
::= { x25StatEntry 8 }
|
|
|
|
x25StatInAccusedOfProtocolErrors OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of packets received containing a
|
|
procedure error cause code. These include
|
|
clear, reset, restart, or diagnostic
|
|
packets."
|
|
REFERENCE "CD 10733 5.9 accusedOfProtocolError"
|
|
|
|
|
|
::= { x25StatEntry 9 }
|
|
|
|
x25StatInInterrupts OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of interrupt packets received by
|
|
the PLE or over the PVC/VC."
|
|
REFERENCE "10733 interruptPacketsReceived"
|
|
::= { x25StatEntry 10 }
|
|
|
|
x25StatOutCallAttempts OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of calls attempted."
|
|
REFERENCE "10733 5.9 callAttempts"
|
|
::= { x25StatEntry 11 }
|
|
|
|
x25StatOutCallFailures OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of call attempts which failed.
|
|
This includes calls that were cleared
|
|
because of restrictive fast select."
|
|
::= { x25StatEntry 12 }
|
|
|
|
x25StatOutInterrupts OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of interrupt packets send by the
|
|
PLE or over the PVC/VC."
|
|
REFERENCE "10733 InterruptPacketsSent"
|
|
::= { x25StatEntry 13 }
|
|
|
|
x25StatOutDataPackets OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of data packets sent by this
|
|
PLE."
|
|
REFERENCE "10733 dataPacketSent"
|
|
::= { x25StatEntry 14 }
|
|
|
|
x25StatOutgoingCircuits OBJECT-TYPE
|
|
SYNTAX Gauge
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of active outgoing circuits.
|
|
This includes call requests sent but not yet
|
|
confirmed. This does not count PVCs."
|
|
::= { x25StatEntry 15 }
|
|
|
|
x25StatIncomingCircuits OBJECT-TYPE
|
|
SYNTAX Gauge
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of active Incoming Circuits.
|
|
This includes call indications received but
|
|
not yet acknowledged. This does not count
|
|
PVCs."
|
|
::= { x25StatEntry 16 }
|
|
|
|
x25StatTwowayCircuits OBJECT-TYPE
|
|
SYNTAX Gauge
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of active two-way Circuits.
|
|
This includes call requests sent but not yet
|
|
confirmed. This does not count PVCs."
|
|
::= { x25StatEntry 17 }
|
|
|
|
x25StatRestartTimeouts OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of times the T20 restart timer
|
|
expired."
|
|
REFERENCE "10733 5.9 restartTimeouts"
|
|
::= { x25StatEntry 18 }
|
|
|
|
x25StatCallTimeouts OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of times the T21 call timer
|
|
expired."
|
|
REFERENCE "10733 5.9 callTimeouts"
|
|
::= { x25StatEntry 19 }
|
|
|
|
x25StatResetTimeouts OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of times the T22 reset timer
|
|
expired."
|
|
REFERENCE "10733 5.9 resetTimeouts"
|
|
::= { x25StatEntry 20 }
|
|
|
|
x25StatClearTimeouts OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of times the T23 clear timer
|
|
expired."
|
|
REFERENCE "10733 5.9 clearTimeouts"
|
|
::= { x25StatEntry 21 }
|
|
|
|
x25StatDataRxmtTimeouts OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of times the T25 data timer
|
|
expired."
|
|
REFERENCE "10733 5.9 dataRetransmissionsTimerExpiries"
|
|
::= { x25StatEntry 22 }
|
|
|
|
x25StatInterruptTimeouts OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of times the T26 interrupt timer
|
|
expired."
|
|
REFERENCE "10733 5.9 interruptTimerExpires"
|
|
::= { x25StatEntry 23 }
|
|
|
|
x25StatRetryCountExceededs OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of times a retry counter was
|
|
exhausted."
|
|
REFERENCE "10733 5.9 retryCountsExceeded"
|
|
::= { x25StatEntry 24 }
|
|
|
|
x25StatClearCountExceededs OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of times the R23 clear count was
|
|
exceeded."
|
|
REFERENCE "10733 5.9 clearCountsExceeded"
|
|
::= { x25StatEntry 25 }
|
|
|
|
-- MIB-II also contains:
|
|
|
|
-- ifInOctets: Number of data octets delivered to upper
|
|
-- layer entities.
|
|
|
|
-- ifInUcastPkts: Number of packets with a clear M-bit
|
|
-- delivered to higher layer entities.
|
|
|
|
-- ifDiscards: Number of packets dropped for lack of buffering
|
|
|
|
-- ifInErrors: Number of packets received containing errors
|
|
-- REFERENCE ProtocolErrorsDetectedLocally
|
|
|
|
-- ifInUnknownProtos: Number of packets with unknown circuit
|
|
-- identifier.
|
|
|
|
-- ifOutOctets: Number of data octets delivered by
|
|
-- X.25 to upper layers.
|
|
|
|
-- ifOutUcastPkts: Number of packets with a clear M-bit
|
|
-- received from higher layer entities.
|
|
|
|
-- ###########################################################
|
|
-- X.25 Channel Table
|
|
-- ###########################################################
|
|
|
|
x25ChannelTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF X25ChannelEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"These objects contain information about the
|
|
channel number configuration in an X.25 PLE.
|
|
These values are the configured values.
|
|
changes in these values after the interfaces
|
|
has started may not be reflected in the
|
|
operating PLE."
|
|
REFERENCE "See ISO 8208, Section 3.7"
|
|
::= { x25 4 }
|
|
|
|
x25ChannelEntry OBJECT-TYPE
|
|
SYNTAX X25ChannelEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Entries of x25ChannelTable."
|
|
REFERENCE "This provides the information available
|
|
in 10733 logicalChannelAssignments."
|
|
INDEX { x25ChannelIndex }
|
|
::= { x25ChannelTable 1 }
|
|
|
|
X25ChannelEntry ::= SEQUENCE {
|
|
x25ChannelIndex
|
|
IfIndexType,
|
|
x25ChannelLIC
|
|
INTEGER,
|
|
x25ChannelHIC
|
|
INTEGER,
|
|
x25ChannelLTC
|
|
INTEGER,
|
|
x25ChannelHTC
|
|
INTEGER,
|
|
x25ChannelLOC
|
|
INTEGER,
|
|
x25ChannelHOC
|
|
INTEGER
|
|
}
|
|
|
|
x25ChannelIndex OBJECT-TYPE
|
|
SYNTAX IfIndexType
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The ifIndex value for the X.25 Interface."
|
|
::= { x25ChannelEntry 1 }
|
|
|
|
|
|
x25ChannelLIC OBJECT-TYPE
|
|
SYNTAX INTEGER (0..4095)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Lowest Incoming channel."
|
|
::= { x25ChannelEntry 2 }
|
|
|
|
x25ChannelHIC OBJECT-TYPE
|
|
SYNTAX INTEGER (0..4095)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Highest Incoming channel. A value of zero
|
|
indicates no channels in this range."
|
|
::= { x25ChannelEntry 3 }
|
|
|
|
x25ChannelLTC OBJECT-TYPE
|
|
SYNTAX INTEGER (0..4095)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Lowest Two-way channel."
|
|
::= { x25ChannelEntry 4 }
|
|
|
|
x25ChannelHTC OBJECT-TYPE
|
|
SYNTAX INTEGER (0..4095)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Highest Two-way channel. A value of zero
|
|
indicates no channels in this range."
|
|
::= { x25ChannelEntry 5 }
|
|
|
|
x25ChannelLOC OBJECT-TYPE
|
|
SYNTAX INTEGER (0..4095)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Lowest outgoing channel."
|
|
::= { x25ChannelEntry 6 }
|
|
|
|
x25ChannelHOC OBJECT-TYPE
|
|
SYNTAX INTEGER (0..4095)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Highest outgoing channel. A value of zero
|
|
indicates no channels in this range."
|
|
::= { x25ChannelEntry 7 }
|
|
|
|
-- ###########################################################
|
|
-- X25 Per Circuits Information Table
|
|
-- ###########################################################
|
|
|
|
x25CircuitTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF X25CircuitEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"These objects contain general information
|
|
about a specific circuit of an X.25 PLE."
|
|
::= { x25 5 }
|
|
|
|
x25CircuitEntry OBJECT-TYPE
|
|
SYNTAX X25CircuitEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Entries of x25CircuitTable."
|
|
INDEX { x25CircuitIndex,
|
|
x25CircuitChannel }
|
|
::= { x25CircuitTable 1 }
|
|
|
|
X25CircuitEntry ::= SEQUENCE {
|
|
x25CircuitIndex
|
|
IfIndexType,
|
|
x25CircuitChannel
|
|
INTEGER,
|
|
x25CircuitStatus
|
|
INTEGER,
|
|
x25CircuitEstablishTime
|
|
TimeTicks,
|
|
x25CircuitDirection
|
|
INTEGER,
|
|
x25CircuitInOctets
|
|
Counter,
|
|
x25CircuitInPdus
|
|
Counter,
|
|
x25CircuitInRemotelyInitiatedResets
|
|
Counter,
|
|
x25CircuitInProviderInitiatedResets
|
|
Counter,
|
|
x25CircuitInInterrupts
|
|
Counter,
|
|
x25CircuitOutOctets
|
|
Counter,
|
|
x25CircuitOutPdus
|
|
Counter,
|
|
x25CircuitOutInterrupts
|
|
Counter,
|
|
x25CircuitDataRetransmissionTimeouts
|
|
Counter,
|
|
x25CircuitResetTimeouts
|
|
Counter,
|
|
x25CircuitInterruptTimeouts
|
|
Counter,
|
|
x25CircuitCallParamId
|
|
OBJECT IDENTIFIER,
|
|
x25CircuitCalledDteAddress
|
|
X121Address,
|
|
x25CircuitCallingDteAddress
|
|
X121Address,
|
|
x25CircuitOriginallyCalledAddress
|
|
X121Address,
|
|
x25CircuitDescr
|
|
DisplayString
|
|
}
|
|
|
|
x25CircuitIndex OBJECT-TYPE
|
|
SYNTAX IfIndexType
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The ifIndex value for the X.25 Interface."
|
|
::= { x25CircuitEntry 1 }
|
|
|
|
x25CircuitChannel OBJECT-TYPE
|
|
SYNTAX INTEGER (0..4095)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The channel number for this circuit."
|
|
::= { x25CircuitEntry 2 }
|
|
|
|
x25CircuitStatus OBJECT-TYPE
|
|
SYNTAX INTEGER { -- state table states
|
|
invalid (1),
|
|
closed (2), -- (p1)
|
|
calling (3), -- (p2,p3,p5)
|
|
open (4), -- (p4)
|
|
clearing (5), -- (p6,p7)
|
|
pvc (6),
|
|
pvcResetting (7),
|
|
startClear (8), -- Close cmd
|
|
startPvcResetting (9), -- Reset cmd
|
|
other (10)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object reports the current status of
|
|
the circuit.
|
|
|
|
An existing instance of this object can only
|
|
be set to startClear, startPvcResetting, or
|
|
invalid. An instance with the value calling
|
|
or open can only be set to startClear and
|
|
that action will start clearing the circuit.
|
|
An instance with the value PVC can only be
|
|
set to startPvcResetting or invalid and that
|
|
action resets the PVC or deletes the circuit
|
|
respectively. The values startClear or
|
|
startPvcResetting will never be returned by
|
|
an agent. An attempt to set the status of
|
|
an existing instance to a value other than
|
|
one of these values will result in an error.
|
|
|
|
A non-existing instance can be set to PVC to
|
|
create a PVC if the implementation supports
|
|
dynamic creation of PVCs. Some
|
|
implementations may only allow creation and
|
|
deletion of PVCs if the interface is down.
|
|
Since the instance identifier will supply
|
|
the PLE index and the channel number,
|
|
setting this object alone supplies
|
|
sufficient information to create the
|
|
instance. All the DEFVAL clauses for the
|
|
other objects of this table are appropriate
|
|
for creating a PVC; PLEs creating entries
|
|
for placed or accepted calls will use values
|
|
appropriate for the call rather than the
|
|
value of the DEFVAL clause. Two managers
|
|
trying to create the same PVC can determine
|
|
from the return code which manager succeeded
|
|
and which failed (the failing manager fails
|
|
because it can not set a value of PVC for an
|
|
existing object).
|
|
|
|
An entry in the closed or invalid state may
|
|
be deleted or reused at the agent's
|
|
convence. If the entry is kept in the
|
|
closed state, the values of the parameters
|
|
associated with the entry must be correct.
|
|
Closed implies the values in the circuit
|
|
table are correct.
|
|
|
|
The value of invalid indicates the other
|
|
values in the table are invalid. Many
|
|
agents may never return a value of invalid
|
|
because they dynamically allocate and free
|
|
unused table entries. An agent for a
|
|
statically configured systems can return
|
|
invalid to indicate the entry has not yet
|
|
been used so the counters contain no
|
|
information."
|
|
REFERENCE "See ISO 8208,
|
|
table 33 for (p<n>) state table"
|
|
::= { x25CircuitEntry 3 }
|
|
|
|
x25CircuitEstablishTime OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The value of sysUpTime when the channel was
|
|
associated with this circuit. For outgoing
|
|
SVCs, this is the time the first call packet
|
|
was sent. For incoming SVCs, this is the
|
|
time the call indication was received. For
|
|
PVCs this is the time the PVC was able to
|
|
pass data to a higher layer entity without
|
|
loss of data."
|
|
::= { x25CircuitEntry 4 }
|
|
|
|
x25CircuitDirection OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
incoming (1),
|
|
outgoing (2),
|
|
pvc (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The direction of the call that established
|
|
this circuit."
|
|
REFERENCE "10733 direction"
|
|
DEFVAL { pvc }
|
|
::= { x25CircuitEntry 5 }
|
|
|
|
-- X25 Circuit data flow statistics
|
|
|
|
x25CircuitInOctets OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of octets of user data delivered
|
|
to upper layer."
|
|
REFERENCE "5.11 octetsReceivedCounter"
|
|
::= { x25CircuitEntry 6 }
|
|
|
|
x25CircuitInPdus OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of PDUs received for this
|
|
circuit."
|
|
REFERENCE "10733 5.11 dataPacketsReceived"
|
|
::= { x25CircuitEntry 7 }
|
|
|
|
x25CircuitInRemotelyInitiatedResets OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of Resets received for this
|
|
circuit with cause code of DTE initiated."
|
|
REFERENCE "10733 remotelyInitiatedResets"
|
|
::= { x25CircuitEntry 8 }
|
|
|
|
x25CircuitInProviderInitiatedResets OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of Resets received for this
|
|
circuit with cause code other than DTE
|
|
initiated."
|
|
REFERENCE "10733 ProviderInitiatedResets"
|
|
::= { x25CircuitEntry 9 }
|
|
|
|
x25CircuitInInterrupts OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of interrupt packets received
|
|
for this circuit."
|
|
REFERENCE "10733 interruptPacketsReceived"
|
|
::= { x25CircuitEntry 10 }
|
|
|
|
x25CircuitOutOctets OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of octets of user data sent for
|
|
this circuit."
|
|
REFERENCE "10733 5.11 octetsSentCounter"
|
|
::= { x25CircuitEntry 11 }
|
|
|
|
x25CircuitOutPdus OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of PDUs sent for this circuit."
|
|
REFERENCE "10733 5.11 dataPacketsSent"
|
|
::= { x25CircuitEntry 12 }
|
|
|
|
x25CircuitOutInterrupts OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of interrupt packets sent on
|
|
this circuit."
|
|
REFERENCE "10733 interruptPacketsSent"
|
|
::= { x25CircuitEntry 13 }
|
|
|
|
-- X25 circuit timer statistics
|
|
|
|
x25CircuitDataRetransmissionTimeouts OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of times the T25 data
|
|
retransmission timer expired for this
|
|
circuit."
|
|
REFERENCE "10733 5.11 dataRetransmissionTimerExpiries"
|
|
::= { x25CircuitEntry 14 }
|
|
|
|
x25CircuitResetTimeouts OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of times the T22 reset timer
|
|
expired for this circuit."
|
|
REFERENCE "10733 5.11 resetTimeouts"
|
|
::= { x25CircuitEntry 15 }
|
|
|
|
x25CircuitInterruptTimeouts OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of times the T26 Interrupt timer
|
|
expired for this circuit."
|
|
REFERENCE "10733 interruptTimerExpiries"
|
|
::= { x25CircuitEntry 16 }
|
|
|
|
x25CircuitCallParamId OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This identifies the instance of the
|
|
x25CallParmIndex for the entry in the
|
|
x25CallParmTable which contains the call
|
|
parameters in use with this circuit. The
|
|
entry referenced must contain the values
|
|
that are currently in use by the circuit
|
|
rather than proposed values. A value of
|
|
NULL indicates the circuit is a PVC or is
|
|
using all the default parameters."
|
|
DEFVAL { {0 0} }
|
|
::= { x25CircuitEntry 17 }
|
|
|
|
x25CircuitCalledDteAddress OBJECT-TYPE
|
|
SYNTAX X121Address
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"For incoming calls, this is the called
|
|
address from the call indication packet.
|
|
For outgoing calls, this is the called
|
|
address from the call confirmation packet.
|
|
This will be zero length for PVCs."
|
|
REFERENCE "10733 calledDTEAddress"
|
|
DEFVAL { ''h }
|
|
::= { x25CircuitEntry 18 }
|
|
|
|
x25CircuitCallingDteAddress OBJECT-TYPE
|
|
SYNTAX X121Address
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"For incoming calls, this is the calling
|
|
address from the call indication packet.
|
|
For outgoing calls, this is the calling
|
|
address from the call confirmation packet.
|
|
This will be zero length for PVCs."
|
|
REFERENCE "10733 callingDTEAddress"
|
|
DEFVAL { ''h }
|
|
::= { x25CircuitEntry 19 }
|
|
|
|
x25CircuitOriginallyCalledAddress OBJECT-TYPE
|
|
SYNTAX X121Address
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"For incoming calls, this is the address in
|
|
the call Redirection or Call Deflection
|
|
Notification facility if the call was
|
|
deflected or redirected, otherwise it will
|
|
be called address from the call indication
|
|
packet. For outgoing calls, this is the
|
|
address from the call request packet. This
|
|
will be zero length for PVCs."
|
|
REFERENCE "10733 originallyCalledAddress"
|
|
DEFVAL { ''h }
|
|
::= { x25CircuitEntry 20 }
|
|
|
|
x25CircuitDescr OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A descriptive string associated with this
|
|
circuit. This provides a place for the
|
|
agent to supply any descriptive information
|
|
it knows about the use or owner of the
|
|
circuit. The agent may return the process
|
|
identifier and user name for the process
|
|
using the circuit. Alternative the agent
|
|
may return the name of the configuration
|
|
entry that caused a bridge to establish the
|
|
circuit. A zero length value indicates the
|
|
agent doesn't have any additional
|
|
information."
|
|
DEFVAL { ''h }
|
|
::= { x25CircuitEntry 21 }
|
|
|
|
-- ###########################################################
|
|
-- The Cleared Circuit Table
|
|
-- ###########################################################
|
|
|
|
x25ClearedCircuitEntriesRequested OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The requested number of entries for the
|
|
agent to keep in the x25ClearedCircuit
|
|
table."
|
|
::= { x25 6 }
|
|
|
|
x25ClearedCircuitEntriesGranted OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The actual number of entries the agent will
|
|
keep in the x25ClearedCircuit Table."
|
|
::= { x25 7 }
|
|
|
|
x25ClearedCircuitTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF X25ClearedCircuitEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A table of entries about closed circuits.
|
|
Entries must be made in this table whenever
|
|
circuits are closed and the close request or
|
|
close indication packet contains a clearing
|
|
cause other than DTE Originated or a
|
|
Diagnostic code field other than Higher
|
|
Layer Initiated disconnection-normal. An
|
|
agent may optionally make entries for normal
|
|
closes (to record closing facilities or
|
|
other information).
|
|
|
|
Agents will delete the oldest entry in the
|
|
table when adding a new entry would exceed
|
|
agent resources. Agents are required to
|
|
keep the last entry put in the table and may
|
|
keep more entries. The object
|
|
x25OperClearEntriesGranted returns the
|
|
maximum number of entries kept in the
|
|
table."
|
|
REFERENCE "See ISO 8208 Section 12.2.3.1.1
|
|
and 12.2.3.1.2"
|
|
::= { x25 8 }
|
|
|
|
x25ClearedCircuitEntry OBJECT-TYPE
|
|
SYNTAX X25ClearedCircuitEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Information about a cleared circuit."
|
|
INDEX { x25ClearedCircuitIndex }
|
|
::= { x25ClearedCircuitTable 1 }
|
|
|
|
X25ClearedCircuitEntry ::= SEQUENCE {
|
|
x25ClearedCircuitIndex
|
|
PositiveInteger,
|
|
x25ClearedCircuitPleIndex
|
|
IfIndexType,
|
|
x25ClearedCircuitTimeEstablished
|
|
TimeTicks,
|
|
x25ClearedCircuitTimeCleared
|
|
TimeTicks,
|
|
x25ClearedCircuitChannel
|
|
INTEGER,
|
|
x25ClearedCircuitClearingCause
|
|
INTEGER,
|
|
x25ClearedCircuitDiagnosticCode
|
|
INTEGER,
|
|
x25ClearedCircuitInPdus
|
|
Counter,
|
|
x25ClearedCircuitOutPdus
|
|
Counter,
|
|
x25ClearedCircuitCalledAddress
|
|
X121Address,
|
|
x25ClearedCircuitCallingAddress
|
|
X121Address,
|
|
x25ClearedCircuitClearFacilities
|
|
OCTET STRING
|
|
}
|
|
|
|
x25ClearedCircuitIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An index that uniquely distinguishes one
|
|
entry in the clearedCircuitTable from
|
|
another. This index will start at
|
|
2147483647 and will decrease by one for each
|
|
new entry added to the table. Upon reaching
|
|
one, the index will reset to 2147483647.
|
|
Because the index starts at 2147483647 and
|
|
decreases, a manager may do a getnext on
|
|
entry zero and obtain the most recent entry.
|
|
When the index has the value of 1, the next
|
|
entry will delete all entries in the table
|
|
and that entry will be numbered 2147483647."
|
|
::= { x25ClearedCircuitEntry 1 }
|
|
|
|
x25ClearedCircuitPleIndex OBJECT-TYPE
|
|
SYNTAX IfIndexType
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The value of ifIndex for the PLE which
|
|
cleared the circuit that created the entry."
|
|
::= { x25ClearedCircuitEntry 2 }
|
|
|
|
x25ClearedCircuitTimeEstablished OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The value of sysUpTime when the circuit was
|
|
established. This will be the same value
|
|
that was in the x25CircuitEstablishTime for
|
|
the circuit."
|
|
::= { x25ClearedCircuitEntry 3 }
|
|
|
|
x25ClearedCircuitTimeCleared OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The value of sysUpTime when the circuit was
|
|
cleared. For locally initiated clears, this
|
|
will be the time when the clear confirmation
|
|
was received. For remotely initiated
|
|
clears, this will be the time when the clear
|
|
indication was received."
|
|
::= { x25ClearedCircuitEntry 4 }
|
|
|
|
x25ClearedCircuitChannel OBJECT-TYPE
|
|
SYNTAX INTEGER (0..4095)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The channel number for the circuit that was
|
|
cleared."
|
|
::= { x25ClearedCircuitEntry 5 }
|
|
|
|
x25ClearedCircuitClearingCause OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Clearing Cause from the clear request
|
|
or clear indication packet that cleared the
|
|
circuit."
|
|
REFERENCE "See ISO 8208 Section 12.2.3.1.1"
|
|
::= { x25ClearedCircuitEntry 6 }
|
|
|
|
x25ClearedCircuitDiagnosticCode OBJECT-TYPE
|
|
SYNTAX INTEGER (0..255)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Diagnostic Code from the clear request
|
|
or clear indication packet that cleared the
|
|
circuit."
|
|
REFERENCE "See ISO 8208 Section 12.2.3.1.2"
|
|
::= { x25ClearedCircuitEntry 7 }
|
|
|
|
x25ClearedCircuitInPdus OBJECT-TYPE
|
|
SYNTAX Counter
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of PDUs received on the
|
|
circuit."
|
|
::= { x25ClearedCircuitEntry 8 }
|
|
|
|
x25ClearedCircuitOutPdus OBJECT-TYPE
|
|
SYNTAX Counter
|
|
|
|
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of PDUs transmitted on the
|
|
circuit."
|
|
::= { x25ClearedCircuitEntry 9 }
|
|
|
|
x25ClearedCircuitCalledAddress OBJECT-TYPE
|
|
SYNTAX X121Address
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The called address from the cleared
|
|
circuit."
|
|
::= { x25ClearedCircuitEntry 10 }
|
|
|
|
x25ClearedCircuitCallingAddress OBJECT-TYPE
|
|
SYNTAX X121Address
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The calling address from the cleared
|
|
circuit."
|
|
::= { x25ClearedCircuitEntry 11 }
|
|
|
|
x25ClearedCircuitClearFacilities OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0..109))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The facilities field from the clear request
|
|
or clear indication packet that cleared the
|
|
circuit. A size of zero indicates no
|
|
facilities were present."
|
|
::= { x25ClearedCircuitEntry 12 }
|
|
|
|
-- ###########################################################
|
|
-- The Call Parameter Table
|
|
-- ###########################################################
|
|
|
|
x25CallParmTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF X25CallParmEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"These objects contain the parameters that
|
|
can be varied between X.25 calls. The
|
|
entries in this table are independent of the
|
|
PLE. There exists only one of these tables
|
|
for the entire system. The indexes for the
|
|
entries are independent of any PLE or any
|
|
circuit. Other tables reference entries in
|
|
this table. Entries in this table can be
|
|
used for default PLE parameters, for
|
|
parameters to use to place/answer a call,
|
|
for the parameters currently in use for a
|
|
circuit, or parameters that were used by a
|
|
circuit.
|
|
|
|
The number of references to a given set of
|
|
parameters can be found in the
|
|
x25CallParmRefCount object sharing the same
|
|
instance identifier with the parameters.
|
|
The value of this reference count also
|
|
affects the access of the objects in this
|
|
table. An object in this table with the
|
|
same instance identifier as the instance
|
|
identifier of an x25CallParmRefCount must be
|
|
consider associated with that reference
|
|
count. An object with an associated
|
|
reference count of zero can be written (if
|
|
its ACCESS clause allows it). An object
|
|
with an associated reference count greater
|
|
than zero can not be written (regardless of
|
|
the ACCESS clause). This ensures that a set
|
|
of call parameters being referenced from
|
|
another table can not be modified or changed
|
|
in a ways inappropriate for continued use by
|
|
that table."
|
|
::= { x25 9 }
|
|
|
|
x25CallParmEntry OBJECT-TYPE
|
|
SYNTAX X25CallParmEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Entries of x25CallParmTable."
|
|
INDEX { x25CallParmIndex }
|
|
::= { x25CallParmTable 1 }
|
|
|
|
X25CallParmEntry ::= SEQUENCE {
|
|
x25CallParmIndex
|
|
PositiveInteger,
|
|
x25CallParmStatus
|
|
EntryStatus,
|
|
x25CallParmRefCount
|
|
PositiveInteger,
|
|
x25CallParmInPacketSize
|
|
INTEGER,
|
|
x25CallParmOutPacketSize
|
|
INTEGER,
|
|
x25CallParmInWindowSize
|
|
INTEGER,
|
|
x25CallParmOutWindowSize
|
|
INTEGER,
|
|
x25CallParmAcceptReverseCharging
|
|
INTEGER,
|
|
x25CallParmProposeReverseCharging
|
|
INTEGER,
|
|
x25CallParmFastSelect
|
|
INTEGER,
|
|
x25CallParmInThruPutClasSize
|
|
INTEGER,
|
|
x25CallParmOutThruPutClasSize
|
|
INTEGER,
|
|
x25CallParmCug
|
|
DisplayString,
|
|
x25CallParmCugoa
|
|
DisplayString,
|
|
x25CallParmBcug
|
|
DisplayString,
|
|
x25CallParmNui
|
|
OCTET STRING,
|
|
x25CallParmChargingInfo
|
|
INTEGER,
|
|
x25CallParmRpoa
|
|
DisplayString,
|
|
x25CallParmTrnstDly
|
|
INTEGER,
|
|
x25CallParmCallingExt
|
|
DisplayString,
|
|
x25CallParmCalledExt
|
|
DisplayString,
|
|
x25CallParmInMinThuPutCls
|
|
INTEGER,
|
|
x25CallParmOutMinThuPutCls
|
|
INTEGER,
|
|
x25CallParmEndTrnsDly
|
|
OCTET STRING,
|
|
x25CallParmPriority
|
|
OCTET STRING,
|
|
x25CallParmProtection
|
|
DisplayString,
|
|
x25CallParmExptData
|
|
INTEGER,
|
|
x25CallParmUserData
|
|
OCTET STRING,
|
|
x25CallParmCallingNetworkFacilities
|
|
OCTET STRING,
|
|
x25CallParmCalledNetworkFacilities
|
|
OCTET STRING
|
|
}
|
|
|
|
x25CallParmIndex OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A value that distinguishes this entry from
|
|
another entry. Entries in this table are
|
|
referenced from other objects which identify
|
|
call parameters.
|
|
|
|
It is impossible to know which other objects
|
|
in the MIB reference entries in the table by
|
|
looking at this table. Because of this,
|
|
changes to parameters must be accomplished
|
|
by creating a new entry in this table and
|
|
then changing the referencing table to
|
|
identify the new entry.
|
|
|
|
Note that an agent will only use the values
|
|
in this table when another table is changed
|
|
to reference those values. The number of
|
|
other tables that reference an index object
|
|
in this table can be found in
|
|
x25CallParmRefCount. The value of the
|
|
reference count will affect the writability
|
|
of the objects as explained above.
|
|
|
|
Entries in this table which have a reference
|
|
count of zero maybe deleted at the convence
|
|
of the agent. Care should be taken by the
|
|
agent to give the NMS sufficient time to
|
|
create a reference to newly created entries.
|
|
|
|
Should a Management Station not find a free
|
|
index with which to create a new entry, it
|
|
may feel free to delete entries with a
|
|
reference count of zero. However in doing
|
|
so the Management Station much realize it
|
|
may impact other Management Stations."
|
|
::= { x25CallParmEntry 1 }
|
|
|
|
x25CallParmStatus OBJECT-TYPE
|
|
SYNTAX EntryStatus
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The status of this call parameter entry.
|
|
See RFC 1271 for details of usage."
|
|
::= { x25CallParmEntry 2 }
|
|
|
|
x25CallParmRefCount OBJECT-TYPE
|
|
SYNTAX PositiveInteger
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of references know by a
|
|
management station to exist to this set of
|
|
call parameters. This is the number of
|
|
other objects that have returned a value of,
|
|
and will return a value of, the index for
|
|
this set of call parameters. Examples of
|
|
such objects are the x25AdmnDefCallParamId,
|
|
x25OperDataLinkId, or x25AdmnDefCallParamId
|
|
objects defined above."
|
|
::= { x25CallParmEntry 3 }
|
|
|
|
x25CallParmInPacketSize OBJECT-TYPE
|
|
SYNTAX INTEGER (0..4096)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum receive packet size in octets
|
|
for a circuit. A size of zero for a circuit
|
|
means use the PLE default size. A size of
|
|
zero for the PLE means use a default size of
|
|
128."
|
|
REFERENCE "10733 proposedPacketSize;
|
|
See ISO 8208 Section 15.2.2.1.1"
|
|
DEFVAL { 128 }
|
|
::= { x25CallParmEntry 4 }
|
|
|
|
x25CallParmOutPacketSize OBJECT-TYPE
|
|
SYNTAX INTEGER (0..4096)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The maximum transmit packet size in octets
|
|
for a circuit. A size of zero for a circuit
|
|
means use the PLE default size. A size of
|
|
zero for the PLE default means use a default
|
|
size of 128."
|
|
REFERENCE "10733 proposedPacketSize;
|
|
See ISO 8208 Section 15.2.2.1.1"
|
|
DEFVAL { 128 }
|
|
::= { x25CallParmEntry 5 }
|
|
|
|
x25CallParmInWindowSize OBJECT-TYPE
|
|
SYNTAX INTEGER (0..127)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The receive window size for a circuit. A
|
|
size of zero for a circuit means use the PLE
|
|
default size. A size of zero for the PLE
|
|
default means use 2."
|
|
REFERENCE "10733 proposedWindowSize;
|
|
See ISO 8208 Section 15.2.2.1.2"
|
|
DEFVAL { 2 }
|
|
::= { x25CallParmEntry 6 }
|
|
|
|
x25CallParmOutWindowSize OBJECT-TYPE
|
|
SYNTAX INTEGER (0..127)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The transmit window size for a circuit. A
|
|
size of zero for a circuit means use the PLE
|
|
default size. A size of zero for the PLE
|
|
default means use 2."
|
|
REFERENCE "10733 proposedWindowSize;
|
|
See ISO 8208 Section 15.2.2.1.2"
|
|
DEFVAL { 2 }
|
|
::= { x25CallParmEntry 7 }
|
|
|
|
x25CallParmAcceptReverseCharging OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
default (1),
|
|
accept (2),
|
|
refuse (3),
|
|
neverAccept (4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An enumeration defining if the PLE will
|
|
accept or refuse charges. A value of
|
|
default for a circuit means use the PLE
|
|
default value. A value of neverAccept is
|
|
only used for the PLE default and indicates
|
|
the PLE will never accept reverse charging.
|
|
A value of default for a PLE default means
|
|
refuse."
|
|
REFERENCE "10733 acceptReverseCharging"
|
|
DEFVAL { refuse }
|
|
::= { x25CallParmEntry 8 }
|
|
|
|
x25CallParmProposeReverseCharging OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
default (1),
|
|
reverse (2),
|
|
local (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An enumeration defining if the PLE should
|
|
propose reverse or local charging. The
|
|
value of default for a circuit means use the
|
|
PLE default. The value of default for the
|
|
PLE default means use local."
|
|
REFERENCE "10733 proposedPacketSize;
|
|
See ISO 8208 Section 15.2.2.6"
|
|
DEFVAL { local }
|
|
::= { x25CallParmEntry 9 }
|
|
|
|
x25CallParmFastSelect OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
default (1),
|
|
notSpecified (2),
|
|
fastSelect (3),
|
|
restrictedFastResponse (4),
|
|
noFastSelect (5),
|
|
noRestrictedFastResponse (6)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Expresses preference for use of fast select
|
|
facility. The value of default for a
|
|
circuit is the PLE default. A value of
|
|
default for the PLE means noFastSelect. A
|
|
value of noFastSelect or
|
|
noRestrictedFastResponse indicates a circuit
|
|
may not use fast select or restricted fast
|
|
response."
|
|
REFERENCE "10733 fastSelect;
|
|
Sec ISO 8208 Section 15.2.2.6"
|
|
DEFVAL { noFastSelect }
|
|
::= { x25CallParmEntry 10 }
|
|
|
|
x25CallParmInThruPutClasSize OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
tcReserved1 (1),
|
|
tcReserved2 (2),
|
|
tc75 (3),
|
|
tc150 (4),
|
|
tc300 (5),
|
|
tc600 (6),
|
|
tc1200 (7),
|
|
tc2400 (8),
|
|
tc4800 (9),
|
|
tc9600 (10),
|
|
tc19200 (11),
|
|
tc48000 (12),
|
|
tc64000 (13),
|
|
tcReserved14 (14),
|
|
tcReserved15 (15),
|
|
tcReserved0 (16),
|
|
tcNone (17),
|
|
tcDefault (18)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The incoming throughput class to negotiate.
|
|
A value of tcDefault for a circuit means use
|
|
the PLE default. A value of tcDefault for
|
|
the PLE default means tcNone. A value of
|
|
tcNone means do not negotiate throughtput
|
|
class."
|
|
REFERENCE "See ISO 8208 Section 15.2.2.2, table 18"
|
|
DEFVAL { tcNone }
|
|
::= { x25CallParmEntry 11 }
|
|
|
|
x25CallParmOutThruPutClasSize OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
tcReserved1 (1),
|
|
tcReserved2 (2),
|
|
tc75 (3),
|
|
tc150 (4),
|
|
tc300 (5),
|
|
tc600 (6),
|
|
tc1200 (7),
|
|
tc2400 (8),
|
|
tc4800 (9),
|
|
tc9600 (10),
|
|
tc19200 (11),
|
|
tc48000 (12),
|
|
tc64000 (13),
|
|
tcReserved14 (14),
|
|
tcReserved15 (15),
|
|
tcReserved0 (16),
|
|
tcNone (17),
|
|
tcDefault (18)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The outgoing throughput class to negotiate.
|
|
A value of tcDefault for a circuit means use
|
|
the PLE default. A value of tcDefault for
|
|
the PLE default means use tcNone. A value
|
|
of tcNone means do not negotiate throughtput
|
|
class."
|
|
REFERENCE "See ISO 8208 Section 15.2.2.2, table 18"
|
|
DEFVAL { tcNone }
|
|
::= { x25CallParmEntry 12 }
|
|
|
|
x25CallParmCug OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Closed User Group to specify. This
|
|
consists of two or four octets containing
|
|
the characters 0 through 9. A zero length
|
|
string indicates no facility requested. A
|
|
string length of three containing the
|
|
characters DEF for a circuit means use the
|
|
PLE default, (the PLE default parameter may
|
|
not reference an entry of DEF.)"
|
|
REFERENCE "See ISO 8208 Section 15.2.2.3"
|
|
DEFVAL { ''h }
|
|
::= { x25CallParmEntry 13 }
|
|
|
|
x25CallParmCugoa OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Closed User Group with Outgoing Access
|
|
to specify. This consists of two or four
|
|
octets containing the characters 0 through
|
|
9. A string length of three containing the
|
|
characters DEF for a circuit means use the
|
|
PLE default (the PLE default parameters may
|
|
not reference an entry of DEF). A zero
|
|
length string indicates no facility
|
|
requested."
|
|
REFERENCE "See ISO 8208 Section 15.2.2.4"
|
|
DEFVAL { ''h }
|
|
::= { x25CallParmEntry 14 }
|
|
|
|
x25CallParmBcug OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..3))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Bilateral Closed User Group to specify.
|
|
This consists of two octets containing the
|
|
characters 0 through 9. A string length of
|
|
three containing the characters DEF for a
|
|
circuit means use the PLE default (the PLE
|
|
default parameter may not reference an entry
|
|
of DEF). A zero length string indicates no
|
|
facility requested."
|
|
REFERENCE "See ISO 8208 Section 15.2.2.5"
|
|
DEFVAL { ''h }
|
|
::= { x25CallParmEntry 15 }
|
|
|
|
x25CallParmNui OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..108))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Network User Identifier facility. This
|
|
is binary value to be included immediately
|
|
after the length field. The PLE will supply
|
|
the length octet. A zero length string
|
|
indicates no facility requested. This value
|
|
is ignored for the PLE default parameters
|
|
entry."
|
|
REFERENCE "See ISO 8208 Section 15.2.2.7"
|
|
DEFVAL { ''h }
|
|
|
|
|
|
::= { x25CallParmEntry 16 }
|
|
|
|
x25CallParmChargingInfo OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
default (1),
|
|
noFacility (2),
|
|
noChargingInfo (3),
|
|
chargingInfo (4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The charging Information facility. A value
|
|
of default for a circuit means use the PLE
|
|
default. The value of default for the
|
|
default PLE parameters means use noFacility.
|
|
The value of noFacility means do not include
|
|
a facility."
|
|
REFERENCE "See ISO 8208 Section 15.2.2.8"
|
|
DEFVAL { noFacility }
|
|
::= { x25CallParmEntry 17 }
|
|
|
|
x25CallParmRpoa OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..108))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The RPOA facility. The octet string
|
|
contains n * 4 sequences of the characters
|
|
0-9 to specify a facility with n entries.
|
|
The octet string containing the 3 characters
|
|
DEF for a circuit specifies use of the PLE
|
|
default (the entry for the PLE default may
|
|
not contain DEF). A zero length string
|
|
indicates no facility requested."
|
|
REFERENCE "See ISO 8208, section 15.2.2.9"
|
|
DEFVAL { ''h }
|
|
::= { x25CallParmEntry 18 }
|
|
|
|
x25CallParmTrnstDly OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65537)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Transit Delay Selection and Indication
|
|
value. A value of 65536 indicates no
|
|
facility requested. A value of 65537 for a
|
|
circuit means use the PLE default (the PLE
|
|
default parameters entry may not use the
|
|
value 65537). The value 65535 may only be
|
|
used to indicate the value in use by a
|
|
circuit."
|
|
REFERENCE "See ISO 8208, Section 15.2.2.13"
|
|
DEFVAL { 65536 }
|
|
::= { x25CallParmEntry 19 }
|
|
|
|
-- The following parameters are for CCITT facilities.
|
|
|
|
x25CallParmCallingExt OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..40))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Calling Extension facility. This
|
|
contains one of the following:
|
|
|
|
A sequence of hex digits with the value to
|
|
be put in the facility. These digits will be
|
|
converted to binary by the agent and put in
|
|
the facility. These octets do not include
|
|
the length octet.
|
|
|
|
A value containing the three character DEF
|
|
for a circuit means use the PLE default,
|
|
(the entry for the PLE default parameters
|
|
may not use the value DEF).
|
|
|
|
A zero length string indicates no facility
|
|
requested."
|
|
REFERENCE "See ISO 8208 Section 15.3.2.1"
|
|
DEFVAL { ''h }
|
|
::= { x25CallParmEntry 20 }
|
|
|
|
x25CallParmCalledExt OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..40))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Called Extension facility. This
|
|
contains one of the following:
|
|
|
|
A sequence of hex digits with the value to
|
|
be put in the facility. These digits will be
|
|
converted to binary by the agent and put in
|
|
the facility. These octets do not include
|
|
the length octet.
|
|
|
|
A value containing the three character DEF
|
|
for a circuit means use the PLE default,
|
|
(the entry for the PLE default parameters
|
|
may not use the value DEF).
|
|
|
|
A zero length string indicates no facility
|
|
requested."
|
|
REFERENCE "See ISO 8208 Section 15.3.2.2"
|
|
DEFVAL { ''h }
|
|
::= { x25CallParmEntry 21 }
|
|
|
|
x25CallParmInMinThuPutCls OBJECT-TYPE
|
|
SYNTAX INTEGER (0..17)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The minimum input throughput Class. A
|
|
value of 16 for a circuit means use the PLE
|
|
default (the PLE parameters entry may not
|
|
use this value). A value of 17 indicates no
|
|
facility requested."
|
|
REFERENCE "See ISO 8208 Section 15.3.2.3"
|
|
DEFVAL { 17 }
|
|
::= { x25CallParmEntry 22 }
|
|
|
|
x25CallParmOutMinThuPutCls OBJECT-TYPE
|
|
SYNTAX INTEGER (0..17)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The minimum output throughput Class. A
|
|
value of 16 for a circuit means use the PLE
|
|
default (the PLE parameters entry may not
|
|
use this value). A value of 17 indicates no
|
|
facility requested."
|
|
REFERENCE "See ISO 8208 Section 15.3.2.3"
|
|
DEFVAL { 17 }
|
|
::= { x25CallParmEntry 23 }
|
|
|
|
x25CallParmEndTrnsDly OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..6))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The End-to-End Transit Delay to negotiate.
|
|
An octet string of length 2, 4, or 6
|
|
contains the facility encoded as specified
|
|
in ISO/IEC 8208 section 15.3.2.4. An octet
|
|
string of length 3 containing the three
|
|
character DEF for a circuit means use the
|
|
PLE default (the entry for the PLE default
|
|
can not contain the characters DEF). A zero
|
|
length string indicates no facility
|
|
requested."
|
|
REFERENCE "See ISO 8208 Section 15.3.2.4"
|
|
DEFVAL { ''h }
|
|
::= { x25CallParmEntry 24 }
|
|
|
|
x25CallParmPriority OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..6))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The priority facility to negotiate. The
|
|
octet string encoded as specified in ISO/IEC
|
|
8208 section 15.3.2.5. A zero length string
|
|
indicates no facility requested. The entry
|
|
for the PLE default parameters must be zero
|
|
length."
|
|
REFERENCE "See ISO 8208 Section 15.3.2.5"
|
|
DEFVAL { ''h }
|
|
::= { x25CallParmEntry 25 }
|
|
|
|
x25CallParmProtection OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..108))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A string contains the following:
|
|
A hex string containing the value for the
|
|
protection facility. This will be converted
|
|
from hex to the octets actually in the
|
|
packet by the agent. The agent will supply
|
|
the length field and the length octet is not
|
|
contained in this string.
|
|
|
|
An string containing the 3 characters DEF
|
|
for a circuit means use the PLE default (the
|
|
entry for the PLE default parameters may not
|
|
use the value DEF).
|
|
|
|
A zero length string mean no facility
|
|
requested."
|
|
REFERENCE "See ISO 8208 Section 15.3.2.5"
|
|
DEFVAL { ''h }
|
|
::= { x25CallParmEntry 26 }
|
|
|
|
x25CallParmExptData OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
default (1),
|
|
noExpeditedData (2),
|
|
expeditedData (3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The Expedited Data facility to negotiate.
|
|
A value of default for a circuit means use
|
|
the PLE default value. The entry for the
|
|
PLE default parameters may not have the
|
|
value default."
|
|
REFERENCE "See ISO 8208 Section 15.3.2.7"
|
|
DEFVAL { noExpeditedData }
|
|
::= { x25CallParmEntry 27 }
|
|
|
|
x25CallParmUserData OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0..128))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The call user data as placed in the packet.
|
|
A zero length string indicates no call user
|
|
data. If both the circuit call parameters
|
|
and the PLE default have call user data
|
|
defined, the data from the circuit call
|
|
parameters will be used. If only the PLE
|
|
has data defined, the PLE entry will be
|
|
used. If neither the circuit call
|
|
parameters or the PLE default entry has a
|
|
value, no call user data will be sent."
|
|
REFERENCE "See ISO 8208 Section 12.2.1.1.6, 12.2.1.2"
|
|
DEFVAL { ''h }
|
|
::= { x25CallParmEntry 28 }
|
|
|
|
x25CallParmCallingNetworkFacilities OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0..108))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The calling network facilities. The
|
|
facilities are encoded here exactly as
|
|
encoded in the call packet. These
|
|
facilities do not include the marker
|
|
facility code.
|
|
|
|
A zero length string in the entry for the
|
|
parameter to use when establishing a circuit
|
|
means use the PLE default. A zero length
|
|
string in the entry for PLE default
|
|
parameters indicates no default facilities."
|
|
REFERENCE "See ISO 8206 Section 15.1, category b"
|
|
DEFVAL { ''h }
|
|
::= { x25CallParmEntry 29 }
|
|
|
|
x25CallParmCalledNetworkFacilities OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0..108))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The called network facilities. The
|
|
facilities are encoded here exactly as
|
|
encoded in the call packet. These
|
|
facilities do not include the marker
|
|
facility code.
|
|
|
|
A zero length string in the entry for the
|
|
parameter to use when establishing a circuit
|
|
means use the PLE default. A zero length
|
|
string in the entry for PLE default
|
|
parameters indicates no default facilities."
|
|
REFERENCE "See ISO 8206 Section 15.1, category c"
|
|
DEFVAL { ''h }
|
|
::= { x25CallParmEntry 30 }
|
|
|
|
-- ###########################################################
|
|
-- X.25 Traps
|
|
-- ###########################################################
|
|
|
|
x25Restart TRAP-TYPE
|
|
ENTERPRISE x25
|
|
VARIABLES { x25OperIndex }
|
|
DESCRIPTION
|
|
"This trap means the X.25 PLE sent or
|
|
received a restart packet. The restart that
|
|
brings up the link should not send a
|
|
x25Restart trap so the interface should send
|
|
a linkUp trap. Sending this trap means the
|
|
agent does not send a linkDown and linkUp
|
|
trap."
|
|
::= 1
|
|
|
|
|
|
x25Reset TRAP-TYPE
|
|
ENTERPRISE x25
|
|
VARIABLES { x25CircuitIndex,
|
|
x25CircuitChannel }
|
|
DESCRIPTION
|
|
"If the PLE sends or receives a reset, the
|
|
agent should send an x25Reset trap."
|
|
::= 2
|
|
|
|
-- ###########################################################
|
|
-- X.25 Protocol Version Identifiers
|
|
-- ###########################################################
|
|
|
|
x25ProtocolVersion OBJECT IDENTIFIER
|
|
::= { x25 10 }
|
|
|
|
-- X.25 CCITT 1976 version.
|
|
x25protocolCcittV1976 OBJECT IDENTIFIER
|
|
::= { x25ProtocolVersion 1 }
|
|
|
|
-- X.25 CCITT 1980 version.
|
|
x25protocolCcittV1980 OBJECT IDENTIFIER
|
|
::= { x25ProtocolVersion 2 }
|
|
|
|
-- X.25 CCITT 1984 version.
|
|
x25protocolCcittV1984 OBJECT IDENTIFIER
|
|
::= { x25ProtocolVersion 3 }
|
|
|
|
-- X.25 CCITT 1988 version.
|
|
x25protocolCcittV1988 OBJECT IDENTIFIER
|
|
::= { x25ProtocolVersion 4 }
|
|
|
|
-- X.25 1987 version of ISO 8208.
|
|
x25protocolIso8208V1987 OBJECT IDENTIFIER
|
|
::= { x25ProtocolVersion 5 }
|
|
|
|
-- X.25 1989 version of ISO 8208.
|
|
x25protocolIso8208V1989 OBJECT IDENTIFIER
|
|
::= { x25ProtocolVersion 6 }
|
|
|
|
-- ###########################################################
|
|
|
|
END
|