mirror of
https://github.com/acidanthera/audk.git
synced 2025-07-22 21:24:35 +02:00
There is no need to issue a full data synchronization barrier and an instruction synchronization barrier after each and every set/way or MVA cache maintenance operation. For the set/way case, we can simply remove them, since the set/way outer loop already issues the required barriers after completing its traversal over all the cache levels. For the MVA case, move the data synchronization barrier out of the loop, and add the instruction synchronization barrier to the I-cache invalidation by MVA routine. Contributed-under: TianoCore Contribution Agreement 1.0 Signed-off-by: Ard Biesheuvel <ard.biesheuvel@linaro.org> Reviewed-by: Mark Rutland <mark.rutland@arm.com> Reviewed-by: Leif Lindholm <leif.lindholm@linaro.org> git-svn-id: https://svn.code.sf.net/p/edk2/code/trunk/edk2@18755 6f19259b-4bc3-4df7-8a09-765794883524
Description
Acidanthera UEFI Development Kit based on EDK II edk2-stable202405
Languages
C
71.6%
Assembly
16.4%
Python
8.5%
Rich Text Format
1.3%
C++
0.8%
Other
1%