Rename check_temp to check_lmsensors

This commit is contained in:
BarbUk 2018-12-23 18:26:24 +04:00
parent d658d231a2
commit 1c3c01f17b
2 changed files with 13 additions and 13 deletions

View File

@ -2601,18 +2601,18 @@ openmanage_timeout | **Optional.** Plugin timeout in seconds [default=30]
openmanage_vdisk_critical | **Optional.** Make any alerts on virtual disks critical
openmanage_warning | **Optional.** Custom temperature warning limits
#### temp <a id="plugin-contrib-command-temp"></a>
#### lmsensors <a id="plugin-contrib-command-lmsensors"></a>
The [check_temp](https://github.com/jackbenny/check_temp) plugin,
The [check_lmsensors](https://github.com/jackbenny/check_temp) plugin,
uses the `lm-sensors` binary to monitor temperature sensors.
Custom attributes passed as [command parameters](03-monitoring-basics.md#command-passing-parameters):
Name | Description
------------------------|----------------------------------------------------------------------------------
temp_warning | **Required.** Exit with WARNING status if above INTEGER degrees
temp_critical | **Required.** Exit with CRITICAL status if above INTEGER degrees
temp_sensor | **Optional.** Set what to monitor, for example CPU or MB (or M/B). Check sensors for the correct word. Default is CPU.
lmsensors_warning | **Required.** Exit with WARNING status if above INTEGER degrees
lmsensors_critical | **Required.** Exit with CRITICAL status if above INTEGER degrees
lmsensors_sensor | **Optional.** Set what to monitor, for example CPU or MB (or M/B). Check sensors for the correct word. Default is CPU.
#### hddtemp <a id="plugin-contrib-command-hddtemp"></a>

View File

@ -205,29 +205,29 @@ object CheckCommand "openmanage" {
}
}
object CheckCommand "temp" {
command = [ PluginDir + "/check_temp" ]
object CheckCommand "lmsensors" {
command = [ PluginDir + "/check_lmsensors" ]
arguments = {
"-w" = {
value = "$temp_warning$"
value = "$lmsensors_warning$"
description = "Exit with WARNING status if above INTEGER degrees"
required = true
}
"-c" = {
value = "$temp_critical$"
value = "$lmsensors_critical$"
description = "Exit with CRITICAL status if above INTEGER degrees"
required = true
}
"--sensor" = {
value = "$temp_sensor$"
value = "$lmsensors_sensor$"
description = "Set what to monitor, for example CPU or MB (or M/B). Check sensors for the correct word. Default is CPU."
}
}
vars.temp_warning = "75"
vars.temp_critical = "80"
vars.temp_sensor = "Core"
vars.lmsensors_warning = "75"
vars.lmsensors_critical = "80"
vars.lmsensors_sensor = "Core"
}
object CheckCommand "hddtemp" {