Differences between Icinga 1.x and 2
Configuration Format
Icinga 1.x supports two configuration formats: key-value-based settings in the
icinga.cfg
cofiguration file and object-based in included files (cfg_dir
,
cfg_file
). The path to the icinga.cfg
configuration file must be passed to
the Icinga daemon at startup.
enable_notifications=1
define service {
notifications_enabled=0
}
Icinga 2 supports objects and (global) variables, but does not make a difference if it's the main configuration file, or any included file.
set IcingaEnableNotifications = 1,
object Service "test" {
enable_notifications = 0,
}
Sample Configuration and ITL
While Icinga 1.x ships sample configuration and templates spread in various object files Icinga 2 moves all templates into the Icinga Template Library (ITL) and includes that in the sample configuration.
The ITL will be updated on every releases and should not be edited by the user.
Note
Sample configuration files are located in the
conf.d/
directory which is included inicinga2.conf
by default.
Include Files and Directories
In Icinga 1.x the icinga.cfg
file contains cfg_file
and cfg_dir
directives. The cfg_dir
directive recursively includes all files with a .cfg
suffix in the given directory. Only absolute paths may be used. The cfg_file
and cfg_dir
directives can include the same file twice which leads to
configuration errors in Icinga 1.x.
cfg_file=/etc/icinga/objects/commands.cfg
cfg_dir=/etc/icinga/objects
Icinga 2 supports wildcard includes and relative paths, e.g. for including
conf.d/*.conf
in the same directory. A global search path for includes is
available for advanced features like the Icinga Template Library (ITL). The file
suffix does not matter as long as it matches the (wildcard) include expression.
include "conf.d/*.conf"
include <itl/itl.conf>
Best Practice
By convention the
.conf
suffix is used for Icinga 2 configuration files.
Resource File and Global Macros
Global macros such as for the plugin directory, usernames and passwords can be
set in the resource.cfg
configuration file in Icinga 1.x. By convention the
USER1
macro is used to define the directory for the plugins.
Icinga 2 uses a global IcingaMacros
variable which is set in the
conf.d/macros.conf
file:
/**
* Global macros
*/
set IcingaMacros = {
plugindir = "/usr/lib/nagios/plugins"
}
Comments
In Icinga 1.x comments are made using a leading hash (#
) or a semi-colon (;
)
for inline comments.
In Icinga 2 comments can either be encapsulated by /*
and */
(allowing for
multi-line comments) or starting with two slashes (//
).
Object names
Object names must not contain a colon (:
). Use the display_name
attribute
to specify user-friendly names which should be shown in UIs (supported by
Icinga 1.x Classic UI and Web).
Object names are not specified using attributes (e.g. service_description
for
hosts) like in Icinga 1.x but directly after their type definition.
define service {
host_name localhost
service_description ping4
}
object Service "localhost-ping4" { }
Templates
In Icinga 1.x templates are identified using the register 0
setting. Icinga 2
uses the template
identifier:
template Service "ping4-template" { }
Icinga 1.x objects inherit from templates using the use
attribute.
Icinga 2 uses the keyword inherits
after the object name and requires a
comma-separated list with template names in double quotes.
define service {
service_description testservice
use tmpl1,tmpl2,tmpl3
}
object Service "testservice" inherits "tmpl1", "tmpl2", "tmpl3" {
}
Object attributes
Icinga 1.x separates attribute and value with whitespaces/tabs. Icinga 2 requires an equal sign (=) between them.
define service {
check_interval 5
}
object Service "test" {
check_interval = 5m,
}
Note
Please note that the default time value is seconds, if no duration literal is given. check_interval = 5 behaves the same as check_interval = 5s.
All strings require double quotes in Icinga 2. Therefore a double-quote must be escaped with a backslash (e.g. in command line). If an attribute identifier starts with a number, it must be encapsulated with double quotes as well.
Unlike in Icinga 1.x all attributes within the current object must be terminated with a comma (,).
Host Service Relation
In Icinga 1.x a service object is associated with a host by defining the
host_name
attribute in the service definition. Alternate object tricks refer
to hostgroup_name
or behavior changing regular expression. It's not possible
to define a service definition within a host definition.
The preferred way of associating hosts with services in Icinga 2 are services defined inline to the host object (or template) definition. Icinga 2 will implicitely create a new service object on configuration activation. These inline service definitions can reference service templates. Linking a service to a host is still possible with the 'host' attribute in a service object in Icinga 2.
Users
Contacts have been renamed to Users (same for groups). A user does not only provide attributes and macros used for notifications, but is also used for authorization checks.
In Icinga 2 notification commands are not directly associated with users.
Instead the notification command is specified using Notification
objects.
The StatusDataWriter
, IdoMySqlConnection
and LivestatusListener
types will
provide the contact and contactgroups attributes for services for compatibility
reasons. These values are calculated from all services, their notifications,
and their users.
Macros
Command Macros
If you have previously used Icinga 1.x you may already be familiar with
user and argument macros (e.g., USER1
or ARG1
). Unlike in Icinga 1.x macros
may have arbitrary names and arguments are no longer specified in the
check_command
setting.
In Icinga 1.x argument macros are specified in the check_command
attribute and
are separated from the command name using an exclamation mark (!
).
define command {
command_name ping4
command_line $USER1$/check_ping -H $HOSTADDRESS$ -w $ARG1$ -c $ARG2$ -p 5
}
define service{
use local-service
host_name localhost
service_description PING
check_command check_ping!100.0,20%!500.0,60%
}
In Icinga 2
Environment Macros
The global configuration setting enable_environment_macros
does not exist in
Icinga 2.
Macros exported into the environment must be set using the export_macros
attribute in command objects.
Checks
Host Check
Unlike in Icinga 1.x hosts are not checkable objects in Icinga 2. Instead hosts
inherit their state from the service that is specified using the check
attribute.
Check Output
Icinga 2 does not make a difference between output
(first line) and
long_output
(remaining lines) like in Icinga 1.x. Performance Data is
provided separately.
The StatusDataWriter
, IdoMysqlConnection
and LivestatusListener
types
split the raw output into output
(first line) and long_output
(remaining
lines) for compatibility reasons.
Initial State
Icinga 1.x uses the max_service_check_spread
setting to specify a timerange
where the initial state checks must have happened. Icinga 2 will use the
retry_interval
setting instead and check_interval
divided by 5 if
retry_interval
is not defined.
Performance Data
There is no host performance data generated in Icinga 2 because there are no real host checks. Therefore the PerfDataWriter will only write service performance data files.
Commands
Unlike in Icinga 1.x there are 3 different command types in Icinga 2:
CheckCommand
, NotificationCommand
and EventCommand`.
For example in Icinga 1.x it is possible to accidently use a notification command as an event handler which might cause problems depending on which macros are used in the notification command.
In Icinga 2 these command types are separated and will generate an error on configuration validation if used in the wrong context.
While Icinga 2 still supports the complete command line in command objects, it's
also possible to encapsulate all arguments into double quotes and passing them
as array to the command_line
attribute i.e. for better readability.
It's also possible to define default macros for the command itself which can be overridden by a service macro.
Groups
In Icinga 2 hosts, services and users are added to groups using the groups
attribute in the object. The old way of listing all group members in the group's
members
attribute is not supported.
The preferred way of assigning objects to groups is by using a template:
template Host "dev-host" {
groups += [ "dev-hosts" ],
services["http"] = {
check_command = [ "http-ip" ]
}
}
object Host "web-dev" inherits "dev-host" { }
Host groups in Icinga 2 cannot be used to associate services with all members of that group. The example above shows how to use templates to accomplish the same effect.
Notifications
Notifications are a new object type in Icinga 2. Imagine the following notification configuration problem in Icinga 1.x:
- Service A should notify contact X via SMS
- Service B should notify contact X via Mail
- Service C should notify contact Y via Mail and SMS
- Contact X and Y should also be used for authorization (e.g. in Classic UI)
The only way achieving a semi-clean solution is to
- Create contact X-sms, set service_notification_command for sms, assign contact to service A
- Create contact X-mail, set service_notification_command for mail, assign contact to service B
- Create contact Y, set service_notification_command for sms and mail, assign contact to service C
- Create contact X without notification commands, assign to service A and B
Basically you are required to create duplicated contacts for either each notification method or used for authorization only.
Icinga 2 attempts to solve that problem in this way
- Create user X, set SMS and Mail attributes, used for authorization
- Create user Y, set SMS and Mail attributes, used for authorization
- Create notification A-SMS, set notification_command for sms, add user X, assign notification A-SMS to service A
- Create notification B-Mail, set notification_command for mail, add user X, assign notification Mail to service B
- Create notification C-SMS, set notification_command for sms, add user Y, assign notification C-SMS to service C
- Create notification C-Mail, set notification_command for mail, add user Y, assign notification C-Mail to service C
Note
Notification objects are not required to be service-agnostic. They may use global notification templates and can be added to a service wherever needed.
Previously in Icinga 1.x it looked like this:
service -> (contact, contactgroup) -> notification command
In Icinga 2 it will look like this:
Service -> Notification -> NotificationCommand
-> User, UserGroup
Escalations
Escalations in Icinga 1.x require a separated object matching on existing objects. Escalations happen between a defined start and end time which is calculated from the notification_interval:
start = notification start + (notification_interval * first_notification)
end = notification start + (notification_interval * last_notification)
In theory first_notification and last_notification can be set to readable numbers. In practice users are manipulating those attributes in combination with notification_interval in order to get a start and end time.
In Icinga 2 the notification object can be used as notification escalation if the start and end times are defined within the 'times' attribute using duration literals (e.g. 30m).
The Icinga 2 escalation does not replace the current running notification. In Icinga 1.x it's required to copy the contacts from the service notification to the escalation to garantuee the normal notifications once an escalation happens. That's not necessary with Icinga 2 only requiring an additional notification object for the escalation itself.
Notification Options
Unlike Icinga 1.x with the 'notification_options' attribute with comma-separated state and type filters, Icinga 2 uses two configuration attributes for that. All state and type filter use long names or'd with a pipe together
notification_options w,u,c,r,f,s
notification_state_filter = (StateFilterWarning | StateFilterUnknown | StateFilterCritical),
notification_type_filter = (NotificationProblem | NotificationRecovery | NotificationFlappingStart | NotificationFlappingEnd | NotificationDowntimeStart | NotificationDowntimeEnd | NotificationDowntimeRemoved)
Note
Please note that
NotificationProblem
as type is required for all problem notifications.
Icinga 2 adds more fine-grained type filters for acknowledgements, downtime and flapping type (start, end, ...).
Note
Notification state and type filters are only valid configuration attributes for
Notification
andUser
objects.
Dependencies and Parents
In Icinga 1.x it's possible to define host parents to determine network reachability and keep a host's state unreachable rather than down. Furthermore there are host and service dependencies preventing unnecessary checks and notifications. A host must not depend on a service, and vice versa. All dependencies are configured as separate objects and cannot be set directly on the host or service object.
Icinga 2 adds host and service dependencies as attribute directly onto the host or service object or template. A service can now depend on a host, and vice versa. A service has an implicit dependeny (parent) to its host. A host to host dependency acts implicit as host parent relation.
The StatusDataWriter
, IdoMysqlConnection
and LivestatusListener
types
support the Icinga 1.x schema with dependencies and parent attributes for
compatibility reasons.
Flapping
The Icinga 1.x flapping detection uses the last 21 states of a service. This value is hardcoded and cannot be changed. The algorithm on determining a flapping state is as follows:
flapping value = (number of actual state changes / number of possible state changes)
The flapping value is then compared to the low and high flapping thresholds.
The algorithm used in Icinga 2 does not store the past states but calculcates the flapping threshold from a single value based on counters and half-life values. Icinga 2 compares the value with a single flapping threshold configuration attribute.
State Retention
Icinga 1.x uses the retention.dat
file to save its state in order to be able
to reload it after a restart. In Icinga 2 this file is called icinga2.state
.
The format objects are stored in is not compatible with Icinga 1.x.
Logging
Icinga 1.x supports syslog facilities and writes its own icinga.log
log file
and archives. These logs are used in Icinga 1.x Classic UI to generate
historical reports.
Icinga 2 compat library provides the CompatLogger object which writes the icinga.log and archive in Icinga 1.x format in order to stay compatible with Classic UI and other addons. The native Icinga 2 logging facilities are split into three configuration objects: SyslogLogger, FileLogger, StreamLogger. Each of them got their own severity and target configuration.
Broker Modules and Features
Icinga 1.x broker modules are incompatible with Icinga 2.
In order to provide compatibility with Icinga 1.x the functionality of several popular broker modules was implemented for Icinga 2:
- IDOUtils
- Livestatus
- Cluster (allows for high availability and load balancing)
In Icinga 1.x broker modules may only be loaded once which means it is not easily possible to have one Icinga instance write to multiple IDO databases. Due to the way objects work in Icinga 2 it is possible to set up multiple IDO database instances.